05-2923 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number;
05-00002923
Property Address:
e-513.1.O�AV.ENIDA=RAMIREZ
APN:
773-083-004-21 -000000-
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
COVE RESIDENTIAL
Application valuation:
16753
Applicant:
M
Architect or Engineer:
4
BUILDING & SAFETY DEPARTMENT
. BUILDING PERMIT
Owner:
GARCIA SAMUEL RODOLFO
51310 AVENIDA RAMIREZ
LA QUINTA, CA 92253
Contractor:
Owner
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/27/07
D In
AUG 28 2001 L
y
LICENSED CONTRACTOR'S DECLARATION.
— — ————————————————————--
WORKER'S COMPENSATION DECLARATION
hereby affirm under penalty of perjury that I am licensed under.. provisions of Chapter 9 (commencing with
I hereby affirm under. penalty of perjury one of the following declarations:
. Section 7000) of Division 3 of the Business and Professionals.code, and.my License.is in full force and effect.
'I have andwijl.maintaina certificate of consent to self -insure for workers' compensation, as.provided
License Class: License No.:
for by Section 3700 of the Labor Code;.for the performance�of- the. work'for which this permit is .
issued.
_ Date: _ ' Contractor: - - --
I have and will maintain workers' compensation insurance, as required by Section 3700 of the ILabor
-
_
Code, for the performance of the work`.for which this peimit is issued. My.workers' compensation
' OWNER -BUILDER DECLARATION ;
insurance carrier and policy number are:
I;hereby, affirm under penalty of perjury that I am exempt from -the Contractor's'Siate License Law .for the
Carrier - Policy Number
- following reason (Sec. 7031.5,.Business and Professions. Code: Any city or county that requires a permit to
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
construct, alter, improve, demolish, or, repair any structure, prior to itsissuance, also -requires the applicant for the
person in any manner so as to become subject to the workers' compensation laws of California,
' permit to file a signed statementthat he or she is licensed pursuant to the provisions of the Contractor's State
and agree that, if I should,become subject.to the workers' compensation provisions of Section
- LicenseLaw (Chapter 9 (commencinjt vvith.Section 7000) of Division 3 of CheBusinessand.Professions Code) or -
3700 of the -Labor Cocomply with those provisions.
i_hat he or she is exempt therefrom and 'the basis for the alleged exemption. Any Any
of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
asowner ofthe property, or my employees with wages as their sole compensation, will do the work, and
the structure isnot intended or offered for sale (Sec. 7044, Business and ProfesSions Code: The
Contractors'�State,License Law does not apply to an owner of property who builds or improves thereon,
and.who-does.the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is.sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose.of sale.)'. '
(_ 1 1, as owner of the property; am. exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business'and Professions Code: The Contractors'' State License Law does not apply to an owner of
property whobuilds or improves thereon, and who contracts for the projects with a contractor(s)'licensed
pursuant to the Contractors' State License Law.). '
1 _ 1 I am exempt under Sdc. , B.&P.C.'for this reason
CONSTRUCTION LENDING AGENCY
I hereby affirmunder penalty of perjury that there is a construction lending agency for.the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
-WARNING: FAILURE TO` SECURE WORKERS'. COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL P.ENALTIES'ANO'CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS (S100,000)..IN ADDITION,TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety fora permit subject to the
conditions and restrictions set forth on this application. -
1 Each person upon whose behalf this application is made, each person at whose request'and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property for inspection purposes.
Date: Signature (Applicant or Agent):
Application Number . . . . . 0.5-00002923
------ Structure Information 235SF RES ADD/443 PAT CVR/V-NR/RES-3 -----
Other struct info . . . . . CODE EDITION 2001/2005
FLOOD ZONE NO
PATIO SQ FTG 443.00
1ST FLOOR SQUARE FOOTAGE 225.00
----------------------------------------------------------------------------
Permit . . .
Additional desc .. .
Permit Fee . . . .
Issue Date . . . .
Expiration Date . .
BUILDING PERMIT
180.00 Plan Check Fee . . 117.00
Valuation . . . . 16753•
2/23/08
Qty Unit Charge Per
Extension
BASE
FEE
45.00
15.00 9.0000 THOU BLDG
----------------------------------------------------------------------------
2,001-25,000
135.00
Permit . . . . . ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . . 25.50
Plan Check Fee
6.00
Issue Date
Valuation . . .
. 0
Expiration Date 2/23/08
Qty Unit Charge Per
Extension
BASE
FEE
15.00
14.00 .7500 PER ELEC
----------------------------------------------------------------------=-----
DEVICE/FIXTURE 1ST 20
10.50
Permit . . . MECHANICAL
Additional desc .
Permit Fee . . . . .46.50
Plan Check Fee
4.88
Issue Date . . . .
Valuation
0
Expiration Date 2/23/08
Qty Unit Charge Per
Extension
BASE
FEE
15.00
1.00 9.0000 EA MECH
FURNACE <=100K
9.00
1.00 4.5000 EA MECH
VENT INST/ DUCT ALT
4.50
1.00 9.0000 EA MECH
APPL REP/ALT/ADD
9.00
1.00 9..0000'EA MECH
B/C <=3HP/100K BTU
9.00
----------------------------------------------------------------------------
Special Notes and Comments
102SF PATIO CONVERSION/123SF
RESIDENTIAL ADDITION/443SF PATIO
COVER/V-NR/RES-3 [ENGINEERED] 2001 CBC,
CMC, 2004 CEC, 2005 ENERGY. August 27,
LQPERMIT
Application Number
. . . . .
05-00002923
----------------------------------------------------------------------------
Special Notes and
Comments
2007 11:44:11 AM
AORTEGA
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
ENERGY REVIEW
FEE
11.70
STRONG MOTION
(SMI) - RES
1.08
Fee summary
Charged
Paid Credited
Due
-----------------
Permit Fee Total
----------
252.00
--------------------
.00
----------
.00
252.00
Plan Check Total
127.88
.00
.00
127.88
Other Fee Total
12.78
.00
.00
12.78
Grand Total
392.66
.00
.00
392.66
J
LQPERMIT
City of. La -Quinn
Building a Safety Division
Permit # . P.O. Box .1504,tr7&4.95 Calle Tampico
La Quinta, CA 9225.3,- (760) 777-7012
• Za��.
-Build.-Ing Perrrlit :Application and Tracking Sheet
Project Address:: �j(• 'fJ� .r Owner's Name:, k
A. P. Number. Address:
Legal Description: City, ST, Zip: s, — 3
_ �.
Contractor: �� C Telephone _ 3M
Address: ° Project Description:
City, ST, Zip: ,
Telephone:
State Lic. # : City Lic. #: V'
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone: : Con traction Type: Occupancy:
State Lic. #: ? Proj tty a(circle one): .New Add'n Alter Repair Demo
Name of Contact Person:`Cl/ 221
Sq. Ft.: �� # Stories: #Units:
�ST Telephone # of Cbntact on: - Persre'll 'Estimated Value of Project:
14� 16-
b. APPLICANT: DO NOT WRITE BELOW THIS LINE
# Submittal Req'd Recd V TRACKING t PERMIT FEES
Plan Sets Plan Check submitted _b - r% Item Amount
Structural Calcs.Reviewed, ready for corrections �96b Plan Check Deposit
Truss Calc s. Called Contact -Person plan Check Balance
Energy Calcs. Plans picked up Construction
Flood plain plan Plans resubmitted(p �. Mechanical
Grading plan 2" Review, ready for/errectijjAuo % Electrical
Subcontactor List Called Contact Person Plumbing
Grant Deed Plans picked upU,' S.M.I.
H.O.A. Approval Plans resubmitted Grading
IN HOUSE:- '"' Review, ready f jorrecti sue Developer Impact Fee
Planning Approval Called Contact Person A.I.P.P.
Pub. Wks. Appr Date of permit: issue '
School Fees
t }
` Total Permit Fees
s If.-?
�� /07J3 /
YIUI-7
07 9TiZ � Y.
Date 7/19/07
No. 29582
Owner Samuel Garcia
Address 51310 Avenida Ramirez
City La Quinta Zip
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road
La Quinta, CA 92253
(760) 771-8515
APN #
4���1F1F�SC�
0
Q BERMUDA DUNES 0
Cn RANCHO MIRAGE
INDIAN WELLS
PALM DESERT y
LA QUINTA 4
QINDIO y0
O
773-083-004
Jurisdiction La Quinta
Permit #
Tract # Study Area
Type Residential Addition No. of Units 1
Lot # No. Street S.F.
Unit 1 51310 Avenida Ramirez 225 Unit 6
Unit 2 Unit 7
Unit 3 Unit 8
Unit 4 Unit 9
Unit 5 Unit 10
Comments Living. Room Addition
Lot # No. Street S.F.
At the present time, thebesert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 5
00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho
mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount,of , $0.00 X 225 S.F. or $0.00. . have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - Samuel Garcia Check No.
Name on the check Telephone 404.7527
Funding Exempt
By Dr. Doris Wilson
Superintendent
Fee collected /exempted
Payment Recd 40.00 �.
Cver/Uriiei _
Signature
NOTICE: Pursuant to Government Le Section 66020(d)(1), this willry to notify you that the 90 -day approval period in which you may protest,the fees o
r other payment identified above will begin to run from the date on whi building or installation permit for this project is issued, or from the date on which
those amounts are paid to the District(s) or to another public entity authorized to collect them on the DistrictCs) behalf, whichever is earlier.
NOTICE: This Document NOT VALID if Duplicated
Embossed Original - Building Department/Applicarit Copy - Applicant/Receipt Copy - Accounting
it
JUN 2 5 2007 �I
TITLE 24 REPORT
Title 24 Report for:
SAMUEL GARCIA
51-310 AVENIDA RAMIREZ
LA QUINTA, CA 92253
Project Designer:
OWNER
SAMUEL GARCIA
LA QUINTA, CA
Report Prepared By:
ADRIANA GIL
Adriana Gil
74-854 Velie Way Ste. #8
Palm Desert, CA 92260
(760).404-7917
Job Number:
ADY389-0206
Date:
5/21/2007
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.3 by EnergySoft Job Number: ADY389-0206 User Number: 5553 I
TA�BLE:O - :CONTENTS
Cover Page 1
Table .of Contents 2
Form CF71'R Certificate:of Compliance 3
Form MF -1 R Mandatory Measures "Summary 6
HVAC System Heating `and Cooling Loads:Summary 8
EnergyPro 4.3 by EnergySoft Job Number: ADY,389-0206 User Number: 5553
Certificate -Of Compliance :-R'es-idential (Part 1 of 3) CF -1 R
_SAM_U_EL GARCIA 5/21./2007
Project Title Date
_51=31.0AV_EN 1DA_RAPMIREZ-LACU_WTA
Project Address Building Permit #
_Adr_iana_Gil (760) 404-7917
Documentation Author Telephone. Plan Check/Date
_Ene-TYero.`_, CA Cl.irna ia-2one 1.5 Field Check/Date
TDV
Building
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.57
2.65
-0.08
Space Cooling
65.54
62.58
2:95
Fans
9.24
8.55
0.70
Domestic Hot Water
0.00
0:00
0.00
Pumps
0.00
0.00
0.00
Totals
77:34
73.78
3.57
Percent better than Standard:
4.66/o.-
:6%..
Building Type: [X-] Single Family
[X_1 Addition
Total Conditioned Floor Area:
225 ft2
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a ft2
Building Front Orientation:
(W) 270 deg
Raised Floor Area:
0 ft2
Fuel Tyne:
Natural Gas
Slab on -Grade Area:
225 ft2
Fenestration:
Area: 70 ft2 Avg. U:
Ratio: .31.1% Avg. SHGC:
BUILDING ZONE INFORMATION
Zone Name Floor Area
-H-VAC-Mini-Split-System 225
AverageCeiling Height: 8.0 ft
0.34 Number of Dwelling Units: 0.13
0.28 Number of Stories: 1
# of Thermostat Vent
Volume Units Zone Type Type Hgt. Area
1.,800 -0J.3_ Conditioned- -Setback- 2 _n/a
OPAQUE SURFACES Insulation Act. Gains Condition
Twe Frame Area U -Fac. Cay. Cont. Azm. Tilt Y / N Status" JA IV Reference Location / Comments
-Roof- Wood- 225_ _0.025_ -RR38_ _R=0_.0- -270_ 1.8
Wall_ Wood_ 42_ -0.102_ -R_13_ _R=0..0_ 9.0_ 9.0
Wall- Wood_ 6.4_ _0.1.02 -R=13_ _R=0.0_ 0_ 9.0
Wall_ Wood- 6.4_ _0.102_ -R_1.3_ -R=0.0_ 1.80_ 90
EX
[X
�X
[X
❑
❑
❑
❑❑
❑❑
❑❑
❑❑
❑❑
F-1
F-1
F-1
F-1
❑❑
F
1-1
F-1
❑
❑New
❑New
El
❑
❑
❑
F-1
F-1
F-1
F-1
❑
F-1
El
New _0141:8 Whole
_0.9_A3 Whole
0.9=A3 Whole
New-, _09=A3 Whole
EnergyPro 4.3 by EnergySoft User Number: 5553 - Job Number: ADY389-0206 Page:3 of 8 1
Certificate Of Compliante._ _ Residential (Part 2 Of 3) CF -1 R
SAMUEL GARCIA 5/21/2007
Project Title Date
FENESTRATION SURFACES
True
Cond.
Location/
# Type
Area LI -Factor" SHGC2
Azm. Tilt
Stat.: Glazing Type
Comments
_1- WindowRear(E)-
8.3_ _0.34.0 _NERC _0.28 -NERC _9.0_
_9.0 N.ew
B.ET_f-ER-B.UILT_Vinyl-low F
Wh.o.le
2 Window Rear (E)
53.3 0.340 NERC 0_28 NFRC
.90 9&:New
BETTER BUILT Vinyl low E
Whole
3 Window Rear (E)_
8.3 0.340 NFRC 0_28 NFRC
90 90 New
BETTER BUILT Vinyl low E
Whole
1. Indicate source either from NFRC or Table 116A. .. 2. Indicate source either from NFRC or Table 116B
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Tv_pe SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt.
1 Bug.Screen 0.76 4.0 1.7 6.0 0.1 6.0 6.0
2 Bug Screen 0.76 6.7 6.0 6.0 0.1 6.0 6.0
3 Bug Screen 0.76 . 4.0 1.7 6.0 0.1 6.0 6.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick: Heat Inside Condition Location/
Type (sq (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Slab Perimeter 30 None No Insulation 26-A1 New Whole
EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY389-0206 Page:4 of 8 1
Certificate Of Compliance: Residential. (Part 3 of 3) CF -1 R
SAMUEL GARCIA 5/21/2007
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Tvpe Eff Tvpe: Eff Status TVDe
HVAC Mini Split System Split Heat Pump 7.20 HSPF Split Heat Pump 11.0 SEER New Setback
HVAC DISTRIBUTION
Duct
Location Heatino Coolino Location
Duct ` Condition Ducts
R -Value Status Tested?
HVAC Mini Split System Ductless / with Ductless n/a n/a New No
-Fan
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated Tank Energy Tank Insul.
Water Heater # in Input Cap. Condition Factor Standby R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping Length (ftL Add 1/2"
Control # HP Type In Plenum Outside Buried Insulation
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed. to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate. has been signed by the individual:with overall design responsibility.
The undersigned recognizes that cdmpliance, using duct:design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require, installer testing and certification and field verification by an -approved HERS rater.
Designer or Owner (per Business & Professions Code) Documentation•Author
Name: Name: ADRIANA GIL
Title/Firm: OWNER Title/Firm: Adriana Gil.
Address: SAMUEL GARCIA
LA QUINTA, CA
Telephone: Lic. #:
(signature)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature)
(date)
(date).
Address: 74-854 Velie Way Ste.,#8
Palm Desert CA 92260
Tele e: (760) 404-7917 /
(s
EnerpyPro 4.3 by Ener. ySoft User Number: 5553 Job Number: ADY389-0206 Pa°e:5 of 8
Mandatory Reasures':Summary: Residential` (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain'these measures regardless of the compliance'approach used. More stringent compliance
R
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parfies;as minimum component performance specifications for the mandatory
measures whether
they are shown elsewhere in the. documents or on this checklist only.
❑
❑X
❑
®ESCI��PTI®IV Check orinitial'applicable boxes or check NA if not applicable and includedwith the
❑
❑X
ENFORCE -1
permitapplication documentation.
N/A
DESIGNER
MENT
Building Envelope Measures
❑
❑X
❑
�§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
0
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls). '
§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
l�
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
❑
❑
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
0
❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
❑
2. No continuous burning gas pilot lights allowed.
❑
LJ
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑X
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑X
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
❑
❑
❑
§ 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
El
ER
❑
CF -6R Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit_ air leakage.
❑
❑X
❑
ti
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
❑
❑X
❑
3. Exterior doors and windows'weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and'Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with,ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑X
❑
§ 1500): Water system pipe and tank.insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
❑X
❑
having an installed thermal resistance of R-12 or.greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table -150B..
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and,Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A:
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
L
LJ
L
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY389-0206
Page:6 of 8
Mandatory Measures Summary Residential . (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain'these measures, regardless of the compliance approach used. More stringent
compliance
compliance requirements from the Certificate of Compliance supersede.'the'items marked with an asterisk, (') below. When this checklist is incorporated
into the permit documents, the features noted'shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents'or on this checklist only.
Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
DESCRIPTION
applicable. N/A DESIGNER MENT
Space Conditioning', Water Heating and Plumbing SystemMeasures; (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604,
❑ 0 ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 161A, or UL 181 B'or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is'used to seal, openings greater than 174 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑ X❑ ❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑ ❑X ❑
duct tapes unless such tape is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
❑ Q ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑ ❑X ❑
dampers.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ ❑X ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑ FX] ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑X ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot <.150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ X❑ ❑
150-C, and do not contain a.medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are
electric and have an output frequency no less•lhan 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ ❑X ❑
luminaire has factory installed HID ballast. r
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
El ❑X El
in Section 130(c), of permanently installed luminaires in kitchens may be'in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires.in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ 191 ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kichens;.bath rooms; garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are congrolled by a dimmer switch OR are
❑ X❑ ❑
controlled by an occupant sensor that complies with Section 1) 9(d) that does not turn on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X ❑
certified to ASTM E283 and labeled as air tight (AT)10 Jess than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a -residential building or to other buildings on the
❑ ❑Q ❑
same lot shall be high efficacy luminaires (not including lighting'around swimming pools/water features or other Article
680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have .lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles,shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of -low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
11 y(d).
EnergyPro 4.3 by EnergySoft User Number: -5553 Job Number: ADY389-0206
Page:7 of 8
r
HVAC SYSTEM HEATING AND COOLING-LOADS'SUMMARY
PROJECT NAME DATE
SAMUEL GARCIA 5/21/2007
(SYSTEM NAME FLOOR AREA
HVAC Mini Split System 225
ENGINEERING CHECKS SYSTEM -LOAD
Number of Systems
1
Heating System
Output per System
10,500
Total Output (Btuh)
10,500
Output (Btuhlsgft)
46.7
Cooling System
Output per System
12,200
Total Output (Btuh)
12,200
Total Output (Tons)
1.0
Total Output (Btuhlsgft)
54.2
Total Output (sgft/Ton)
221.3
Air System
CFM per System
0
Airflow (cfm)
0
Airflow (cfm/sqft)
0.00
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 of
Outside Air
0 cfm
70.0 of
Total Room Loads
Return Vented. Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel
Latent
CFM
I Sensible
250 5,588 1,031 87 3,705
0
0 0
0 0
0�1 011 0 0
0 0
0 0
5,588 1,031, 3,705
FUJITSU AOU12C1 10,288 48 6,558
Total Adjusted System Output 10,288 48 6,558
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
70.0 of 110.0 of
Heating Coil
res afTime of Heatina
h - Return Air Ducts "I
$ Supply Air Ducts
110.0 of
ROOMS
70.0 of
(COOLING SYSTEM PSYCHROMETRICS (Airstream Temoeraturessat Time:of`Coolina Peakl I
11.0/77.6OF 76.0/61.7OF 55.0/53.8OF
r %� % S
Outside Air
0 cfm
76.0 / 61.7 of
Cooling Coil
Return Air Ducts
upply Alr Ducts
55.0 / 53.8 of
44.4% R.H. ROOMS
76.0 / 61.7 of
EnergyPro 4.3 by EnergySoft User Number: 5553 Job Number: ADY389-0206 Page:8 of 8