Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0060
VOICE (760) 777-7125 78-495 CALLE TAMPICO D -` LA QUINTA, CALIFORNIA 92253fAX (760) 777-7011 'COMMUNITY DEVELOPMENT :DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT -:J Date: .5/21/2015 Application Number: BSOL2015-0060 D Owner: Property Address: 51905 AVENIDA.RAMIREZ RYAN. FLORES APN: 773165020 AA //����// 11 %(�t5 519.05 AVENIDA RAMIREZ Application Description: RYAN / (24)-ROOF'MOUNTED OLAR ANElS`AN�(i) INVERTER LA QUINTA , CA 92253 Property Zoning: Application Valuation: $13,790.40 "CITYOF.L.A.OUINTA Applicant: COMMUNITY DEVELOPMENT DEPARTMENT Contractor: SOLARCITY CORPORATION SOLARCITY CORPORATION ' 3055 CLEARVIEW WAY 3055•CLEARVIEW WAY ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 LIc. No.: 888104 ---------------=---------------------------------------------------------- ----- -------- - - - -- = LICENSED CONTRACTOR'S DECLARATION WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury that I am licensed Lnder.provisions of Chapter: I hereby affirm under penalty of perjury one of the following declarations: 9 (commencing with Section 7000) of Division 3 he Busi "ss and Professions Code, I have and will maintain a "certificate of consent to self -insure for workers' and my License is in full force and eff compensation, as provided for by Section 3700 of the Labor Code, for the performance License Class: C46 B C10 A Liens N : 888 04 of the work for which this permit,is'issued. 1 have and will maintain workers' compensation insurance, as required by Date: Contract Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insUi ance carrier and polity number are: OWNER -BUILD .DECLARATION I hereby affirm under penalty of perjury that l am exempt.fro the Contractor's State License Law for the following reason (Sec. 7031.5, Business anis Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter.9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or -she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7631.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (� 1, as owner of the property, or my employees with wages as their sole compensation, will do the.work,_and the structure is not intended, or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon;.and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however; the building orimprovement is sold within one year of completion,.the owner -builder will haveJhe burden of'proving that he or she did not build or improve for the purpose of sale.).. . (_) I'' as owner of the property, am exclusively contracting.with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law.does not apply to an owner of property who. builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (� I am exempt under Sec. B.&P.C. for this reason' Date: Owner: CONSTRUCTION LENDING•AGENCY I hereby affirm under penalty of perjury that there is'a construction lending agency for the performance of•the work for which this permit is issued (Sec.'3097, Civ. C.). > Lender's Name: Lender's Address: Carrier: _ Policy Number: I certify,that•in the performance of the work for which this permit is issued, I shall not employ any person in any,manher so as to become subject to the workers' compensation laws of California, andagree that, if I sho beco a subject to the . workers' compensation provisions of Section 37 f e L bo C de, I shall forthwith comply witN those ovisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION CO RAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AN IVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF .COMPENSATION; DAMAGES AS PROVIDED. FOR, IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby. made to the Building Official for a permit subject to the conditions and.restrictions set forth on. this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. -Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of Work for 180 days will subject permit to cancellation. I certify that have read this application and state that the above information is correct. Lagree to comply with all city and county ordinances and state .la elating to building construction, and hereby authorize repr a tives of thi a to( the above mentione ,pro erty for inspection purpo " s.' Date: Signature (Applicant r Agent J^ .9 �y.��'� �xs�,,.�'`'3 �$'—�--_:', §.� iWl.!�,3t�`_,`..� ":�.,W: �. 7'#x �.�:F-rda ���.'-R�"�1;3�-M„^8tv�53'.. '3�.y:X cu 3. Y���''.��t.. �-y`�d ".�i..�A2�i� "'�'•� �.. wi.`.:$ �6wy,"m�.:x. �9`�Ty�z4'$.P�.: `5 �:-.:'.x._ :a�.>?. �aii�Y�Sv3eiz7:«:�i'' �"16.I�a'.•i;«'� tl* 'a'=h_...E _ BSAS S81473 FEE 101 0000 20306` i -'" 0 `; $1;00 ` $1:00.. aA S/21/15 ryi�'hyG�•'X 5 "rvf"S, f'"` S'"1" ': SEU`TS�'.; : `= .Y"FY '"',p5•.;; SY!-"-' iFY � ^4? X '' '` HE K TD"BYE SOLARCITY-CORPORATION. CHECK R6342 210886 MFA Total Paid forBUILDING STANDARDS ADMINISTRATION BSA . .$1.00 $1:00 t, *�c rz�� DESCRIPTION ,t<� �r°Y x n si .� �!�' �. � � m!�� ` s+ACCOUNT OMEN,�1,a %•�..,�xst � �QTbY z�i n r �,�a � r AMOUNTS - V MF ERNE �--« �� F PAID�� � T`a.���, PAID DATE: ,s�,:._ ,e� .: PV SYSTEM - ARRAY,'FIRST 10 ,101 0000-42403 ^"�`�'y-;'�,'6`-'�i�§i'�,+��. 0 $24 17'.. . $14:17. 5/21/15 o o nj b4g'S"h• "pix ���A PAIDBYx, ,,V ,�",�,a'c'y SME=THOD5h�ECE � iY� .�,.�i5, $" l.� �Z � � , .� � �� .:��y.; w�`3SR3£_�� � CHECK # `: � �CLTD BY. >f PT# ,, x SOLARCITY CORPORATION •y CHECK K6342' ' _. .220886.. MFA zS "S:?, 'A ,-ssp5 , tz3E's:::7. ';. ;:s. s' v `�`Ys«;arz--+" s'".eRa.&r"'+.8"'. iFat �"Sai k.,'9. :,-,; •as a &s`' a'"9 �''�5' 'ips-""" ? .PA IDyDATEE' :�� PV SYSTEM. -..ARRAY; FIRST 20-PC •' 101-0000-42600 0 ' :$24 17$24.17 5/21/15 �.� _`�` '� � '�• - �, �c�� �� ���� �,:�, ���s� , � , : Rte:: ����� � �d� �•:�: � � �, � €��� >�,;��, �t�� -M SOLARCITY CORPORATION :CHECK:'. R6342 " 110886 MFA TofaliPaid.focELECTRICAL: $48.34 $48.34 4+:n•::£« " sDESCRIPTION, ia"�.{_, _..y++,+`=i='.v.' mak, a�"Qs» �,.zrt. �•F�:.ii=,�'-'.1 iME Tr NAID*SEA,? PAID DATE° �e'::3�tryL` PERMIT ISSUANCE 101=000042404. 0. .; . $91:85, *$91.85 5/21/15 h�� i r 1 �r. '. .M Y IRWINTX K.. DB�, SOLARCITY CORPORATION `CHECK. R6342 :; , 220886" MFA Total Paid for PERMIT ISSUANCE $91 85 .. $91.85 m Description: RYAN (24) ROOF MOUNTED SOLAR PANELS AND (1) INVERTER Type: SOLAR Subtype: Status: ISSUED Applied: 5/14/2615 SKH Approved: 5/20/2015 JFU Pircel- No: 773,1650.20 Site Address: 51,905 AVENIDA RAMIREZ LA QUINITACA 92.253 Subdivision: SANTA CARMELITA VALE LA.QUINT Block: 58 Lot: 8. Issued: 5/21/2015.M,FA UNIT 5 Mon '00 'R27' tdt'S4 . Tt-I W-'' - 136i ldih'd'Sq'Ft:"0.; Zoning:' Fi led: Valuation: $13;190;40 Occupancy Type: Construction Type: Expired: 11/17/2015 MFA Buildings: No: Stories: 0 No. Unites: 0 -KU2606XPA =O 'Z &taiis':'.'6`2'4kW SOLAR ARRAY '(24) i6w.kYodRA PANELS" (I) ABB UTD-�US-' -A' INVERTER 305Ff2013 CALIFORNIA -ELECTRICAL CODE. ... . . ........... . Mon '00 'R27' M .7, �� PRE !II m 'm 16ak ITY:CO I RP . ORAT . ION• •RYAW VLORES •0 •# ILA �QV!NTA EZ... - IRA am, • CLTD,� DESCRIPTION ACCOUNT QTY AMOUNT PAID_ PAID DATE RECEIPT,#' CHECK #: METHOD PAID BY - BY BSAS SB1473 FEE 101-0000-20306 0 $1.00 $1.00 5/21/15 R6342 220886 CHECK SOLARCITY MFA" CORPORATION Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $1.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $24.17 5/21/15 R6342 220886 CHECK SOLARCITY MFA FIRST 20 CORPORATION PV SYSTEM -ARRAY, 101-0000-42600 0 $24.17 $24.17 5/21/15 R6342 220886 CHECK SOLARCITY MFA FIRST 20 PC CORPORATION Total Paid for ELECTRICAL: $48.34 $48.34 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 5/21/15 R6342 220886 CHECK SOLARCITY MFA CORPORATION Total Paid for PERMIT ISSUANCE: $91.85 $91.85 _ TOTAL SEQID INSPECTION TYPE :' . INSPECTOR SCHEDULED COMPLETED RESULT REMARKS - - NOTES ., DATE DATE SOLAR FINAL•" BLD ATTACHMENTS Printed: Thursday, May 21, 2015 11:00:35 AM 2 of 2 SYSTEMS 1 Bin.# City of U- Quints BulkMg 8r Safety Division P.O. Box 1504,,78-49S. Calle 7ampfco 4.Quinta, CA 92253-:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # p�Sv a S' Project Address: Owner's Name:.. YMAW A P. Number Address: {� Legal Description: City, ST, Zap: La Quinta, CA Contractor. Solar City Telephone: PcojectI)escriptioa: roof mounted solar panels . Address: 3055 Clearview Way. city, Sr, zip: San Mateo, CA,..94402 inverter(s) Telephone: 650-638-1028 state Lia # : 888104 City Lie'. #; Arcfi., Eng., Designer Address: City, ST. Zip: Telephone: State Lia #: - Name of Contact Person Melanie PI asse Construction Type:. Oxupancy: Prqject.type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: # Units: Telephone # of contact Pelson: 760-552-0663 Estimated Value of Project APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal ReVd " Beed TRACKING PERM[F FEES Plan Sets Pian Cheek submitted Item Amount Structural Calcs. Reviewed, ready for corrections 5 leo Plan Cdeck Deposit Truss Cates. Called Contact Person Jam' Zp Pias Check Balance _ Inde 24 Calcs. Plans picked up Construction' Rood plain plan Plans resubmitted Mechanical Giading plan Z'! Review, ready for correctioneiwue Electrical Subeontactor List Called CoutactPerson Plumbing Grant Deed Plans picked up S bLL H.O.A. Approval Plam.resubmitted Grading IN HOUSE:- ''" Bevtew, ready for corrections/issue Developer Impact Fee Planning Approval. 1,calleaContactPerson A:I.P.P. Pub. Wks. Appr Date of permit issue School Fees na%frml V QU MAY 14.2.015 . CITY OF LA QUINTA COMMUNITY DEVELOPMENT to ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES e A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN CONIC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. U) (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING . MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER 1 AA �1 U1'M'A OF kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR CITY • L kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING & SAFETY DEn LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED•WITH STRAIN wt .APPROVED FORCONSTRUMON (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE OC ON CENTER 9. MODULE FRAMES SHALL BE GROUNDED AT THEZD UL—LISTED LOCATION PROVIDED BY THE IL. 101 ff V 1 PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED NTH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VICINITY MAP INDEX Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT F — W WATT Wx _ a "` 3R NEMA 3R, RAINTIGHT ,, - 4z PV1 COVER SHEET , PV2 SITE PLAN - PV3 STRUCTURAL VIEWS �,: PV4 p `PV5 UPLIFT CALCULATIONS THREE LINE DIAGRAM LICENSE GENERAL NOTES - :, - !� y �' ��'!� - "� .. PV6 ONE LINE DIAGRAM P ELECTRICAL CALCULATIONS CV s eets Attached CA 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 - ¢- CALIFORNIA RESIDENTIAL CODE. n 2. ALL ELECTRICAL WORK SHALL COMPLY NTH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY 1 THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR bµ i Y ' REV& BY DATE COMMENTS AHJ: La Quints t REV A NAME DATE COMMENTS UTILITY: Imperial Irrigation District CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9223414 OO PREMISE OWNER: FLORES, RYAN DESCRIPTION: FLORES RESIDENCE DESIGN: Jar ret Ha MOUNTING SYSTEM:WH ZEP Mighty Hook BENEFIT OF ANYONE EXCEPT SOLARCITY INC., SHALL IT BE DISCLOSED IN OLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS 51905 AVENIDA RAMIREZ 6.24 KW PV ARRAY ,NOR 501arCity. I„ MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH LA QUINTA CA 92253 , aearview Way THE SALE AND USE OF THE RESPECTIVE (24) KYOCERA # KU2606XPA APN: 773165020PAGE SHEET: PV DATE 5/13/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INCB NAME (760) 404-8946 COVER SHEET San Mateo, CA 94402 T:(650) 638-1026 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.sdarcity.com FTER: PVI-5000-OUTD—US—Z—A E At I_1 AT itU A, %J ; :930 MiAa 2 ox- 10 Nua GV0ggA i �3ITOURT8000 fiol Iva TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V -METER# 164SR-101390 "PROPOSED BI-DIRECTIONAL METER#— CUTLER -HAMMER # DG221URB - AC DISCONNECT: 1 1 FT FROM MAIN PANEL INVERTER: ABB PVI-5000-OUTD-US-Z-A 3' FSB O O O I O O O O O I I I o 0 0 O SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION OF SOLARCITY INC. ABB # PVI -50 ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS 4 O O O — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED I INTERIOR EQUIPMENT IS DASHED O O O Scale: 1/8" = V W E O 1' 8' - 16' Ed smamm S DESIGN: Jarret Hauger ' O O O O 3055 Clearvlew way San Mateo, CA 94402 T:(650) 636-1028 F:(650) 638-1029 SHEET: REV: DATE PV 2 5/13/2015 O O O O 0 0 0 0 m In LL M Pitch '5/t2 I° 3' -FS7B- AC O © Inv iA, 240V, SINGLE PHASE MRES, 22kAiC STING BI DIRECTIONAL TER## 164SR-101390 CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB - CONTAINED SHALL NOT BE USED FOR THE lay INVERTER W/ INTEGRATED DC DISCO BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Ho 1 PART TO OTHERS OUTSIDE THE RECIPIENT'S Ar AC DISCONNECT & WARNING LABELS OB DC JUNCTION/COMBINER BOX & LABELS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE MODULES (24) KYOCERA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION OF SOLARCITY INC. ABB # PVI -50 av 23414 00 ;U2606XPA OUTD-US-Z-A tam CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE BY V T PREMISE OWNER: FLORES, RYAN 51905 AVENIDA RAMIREZ LA QUINTA, CA 92253 (760) 404-8946 Front Of Hou G) a, n (E) DRIVEWAY a DESCRIPTION: FLORES RESIDENCE 6.24 KW PV ARRAY PAGE NAME SITE PLAN Ln (D PITCH: 20 ARRAY PITCH: 20 MP1 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Low Profile W -Tile STORY: 1 S1 I F[;FNn Q (E) UTILITY METER & WARNING LABEL lay INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS Ar AC DISCONNECT & WARNING LABELS OB DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER 0 STANDOFF LOCATIONS -� CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L _�J SITE PLAN N Scale: 1/8" = V W E O 1' 8' - 16' Ed smamm S DESIGN: Jarret Hauger SolarCity. t LA] 00 3055 Clearvlew way San Mateo, CA 94402 T:(650) 636-1028 F:(650) 638-1029 SHEET: REV: DATE PV 2 5/13/2015 (888) -SOL -CITY (765-2489) www.solarcity.com N wvv F.1 vi iic vv- i iic INSTALLATION ORDER LOCATE 'RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. 2) CLEAN PAPER AROUND PILOT HOLE. ADJUST STANDOFF TO BATTEN 3) HEIGHT. SEAL PILOT HOLES AND -BOTTOM (4) OF. STANDOFF WITH POLYURETHANE SEALANT. 5) LAG STANDOFF INTO RAFTER. Q6) NOTCH TILE WEATHERING TO FIT AROUND STANDOFF. 7) REINSTALL TILE. CONFIDENTIAL A THE INFORMATION HEREIN CONTAINED'SHALL NOT BE USED FOR THE .BENEnT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR INEP. PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. NUMBER JB -9223414 00 PREMISE OWNER: DESCRIPTION: FLORES, RYAN FLORES RESIDENCE' 51905 AVENIDA RAMIREZ 6.24 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME: 760 404-8946 ) STRUCTURAL VIEWS DESIGN: Jarret Hauger ; • •c OI�� _ 't 0, Y NTING SYSTEM _ Mighty Hook ULES 4) KYOCERA # KU2606XPA [ABB 3055 Clearvie�i. Woy San Mateo, CA.94402 (Be �sso�i�asTY (is�2 F:(650) �:�. lI«iYa«n SHEET: REV. DATE PV 3 5/13/2015 R1E� PVI-5000—OUTD—US—Z—A UPLIFT CALCULATIONS 05.13.2015 PV System Structural Version #44.7 1 P,;SolarCity Design Software Project Information & Table_ Of Contents Risk Category: PV Syskem Type Spanish Tile Roof A BEUSEDFOR CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN _ II (a –1 Sl7" 6upt'"` _ _Spanish Tile Roof 0'�� MOUNTING SYSTM ZEP Mighty Hook Layers of Com Roofln PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253Way Roof Slope Rafter. ` acin 3055 _ 200. 24" O:C .–_ PV Sys�•t_em Module TJrientation PV Module Area.. PV Module. Width 440 Mateo, CA 94402 638-1028 Son Mateo. F:(650) 638-1029 (SOL,CRY and Landscape Portrait. SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN (760) 404-8946 UPLIFT -CALCULATIONS 425sf 39" (888) (785-2489) www.sdordty.Com PV MModule (Fn7gth Standoff Attachment Hardware PERMISSION OF SOLARCITY INC. 6S` Mighty Hook HDG ST Reduced Ground/Roof l nre/Snow Loads_ - Ground Snow Load Pg— 0.0 Psf 0 6,psf 0.0 ASCE Table 7-1 ASCE Eq:.741 ASCE E :'7.4-1 Surrounding Roof $now Roof Snow Over PV Modules Wind Design Criteria Wind Design Code Wind Design_Med d Basic Wmd Speed Exposure Categpry Roof Style Mean Raof Height Effective Wind.Area 1 Module _ ASCE 7-10 Partially%Fully Endosed Method 110 mph G Gable Roof 15_ftSediors _ . Flg.26.54A Lwion 26;7 rag. 304-2,NK-5A/8 26:7 IBC 1509.7.1 V h A 17.7 sf Wind Pressure Calculation Coefficients Wind Pressure Exposure Topographric: Fad6 Wind Directionality Factor- r Importance Factor Kz _� Kd �11 0.85 0.85 NA Table 30.3-1 _3 64 Section 26.64_ Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Ext Pressure Coefficient,(Up) � EM. Pressure Coeftifent Down �GCp (lJp) G Down -0:88 Rg. 3o.a zA/e/e-sNe 0.45 Fg.30:42A/8/C-5A/B Design Wind Pressure = ah GC Equation 30.4-1 Wind Pressure Up- — Wind Pressure Down —P('AP),r._,_ -19.6_psf down 16.0 Allowable Standoff Spacings X -Direction .Y -Direction Max Allowable Standoff Spa^ang� Max AllowableyCarrtileyer Standoff Confi uration. Landscape _Landscape Landscape ___ ___� 24" Not -Staggered 40"" 20° Max Standoff Trlbutary,Area PV Assembly Dead Load Net;Wind Uplift at Standoff Uplift Capacity of Standoff_ Trib W -PV T actual T -allow 13 sf 3 psf -134,Ibs 350 Itis' Standoff Demand Ca a DCR 38.3% Max Allowable Standoff Spacing, Max Allowablee_9ntilever Standoff Configuration Portrait ,,,.._.Pgrt@lt',___ _ 48" 2O" 40" =6 Portrait. Not -Staggered Max Standoff Tributary Area_ - PV Assembly_Dead Load Net__Wind Uplift at Standoff Uplift Capacity of Standoff Standoff Demand Ca a EuDGR �Trl6_ VV -PV _ T aitu l„ T -allow _ 13 sf 3 psf '134 lbs 350 lbs 38.3% THE INFORMATION CONFIDENTIALTAINS Ioe NUMBER. JB -9223414 �0 PREMISE OWNER: DESCRIPTION: FLORES, RYAN FLORES RESIDENCE DESIGN Jarret Hauger �-IQ`0,;SolarCity. A BEUSEDFOR CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 51905 AVENIDA RAMIREZ 6.24 KW PV ARRAY 0'�� MOUNTING SYSTM ZEP Mighty Hook PART TO OTHERS OUTSIDE THE RECIPIENTS LA QUINTA, CA 92253Way 3055 MODULES (24) KYOCERA # KU2606XPA ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE PAGE NAME: 440 Mateo, CA 94402 638-1028 Son Mateo. F:(650) 638-1029 (SOL,CRY SHEET REV. DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN (760) 404-8946 UPLIFT -CALCULATIONS PV 4 5/13/2015 (888) (785-2489) www.sdordty.Com INVERTER: PERMISSION OF SOLARCITY INC. ABB PVI-5000—OUTD—US—Z—A GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) UFER AT PANEL Panel Number: SMB101224SN Inv 1: DC Ungrounded INV 1 — (1) ABB # PVI-5000—OUTD—US—Z—A LABEL: A — (24) KYOCERA # KU2606XPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: 1B4SR-101390 FCI Inverter; Zigbee 5000W, 240V, 96.5% PV Module; 260W, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Ba kbor C-10 INV 2 Underground Service Entrance Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC SPRINGS IDENTIFIER E 125A CENTER—FED MAIN SERVICE PANEL E 10OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! CUTLER—HAMMER Inverter 1 IND 1 10OA/2P Disconnect 3 ABB Oc, Vstart = 120V PVI-5000—OUTD—US—Z—A t IDGI— MP 1 1x12 E LOADS A 24aV �� r—————---------------- EGC _ _ --------- — — — — — — — — — • L2 DC+ I 30A/2P GND N oc I DC, Vstart = 120V ---- ------------------------------------- A —EGCI --- GEC �D MP 1: 1x128EGC +Dc- I 1 ------------------------------------------------pj (1) Conduit Kit; 3/4' EMT N I I EGC/GEC — Z Z c9 — — — GEC _ _ 1 PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED TO 120/240V I AND GROUPED: THE MEANS OF IDENTIFICATION SHALL BE SINGLE-PHASE I UTILITY SERVICE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. THE MEANS OF CITY OF LA QUINTA GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN'AT INTERVALS NOT TO EXCEED SIX (6) BUILDING & SAF TY DEPT. FEET. ' APPROVED PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE FOR CONSTRUCTION INSTALLED ONLY BY QUALIFIED PERSONS DATE BY Voc* = MAX VOC AT MIN TEMP PUT—(1)CUTLER—HAMM # BR230 PV BACKFEED BREAKER Breaker, 30A 2P, 2 Spaces A (1)CUTLER—HAMMER 8 DG221URB A C Disconnect; 30A, 24OVac, Non—Fusible, NEMA 3R A DC — (1)CUTLER—�IAMMER � DG03ONB Ground eutrol kt; 30A;'General Duty (DG) O 6E1 AWG 810, THWN-2, Black (I) AWG 810, THWN-2, Red 2 AWG 810, PV Wire, 600V, Black Voc* = 517.51 VDC Isc = 9.09 ADC O (1)AWG 810, Solid Bare Copper EGC Vmp = 372 VDC Imp= 8.39 ADC ���LLL (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp= 23 AAC (1 %%Conduit Kit;. 3/4'_ EMT . • ..... 70 AWG #8,, TI1"72., Green . , EGC/GEC.- (I) Conduit, Kit;. 3/47.EMT .......... .. (2) AWG 810, PV Vire, 60OV, Block Voc* = 517.51 VDC Isc = 9.09 ADC O(1)AWG 810, Solid Bare Copper EGC Vmp = 372 VDC Imp= 8.39 ADC ( I) Cqn0git Kit; 3/4' EMT ......................................... N HEREIN —THE INFORMATIOFOR -FOR JOB NUMBER JB-9223414 00 PREMISE OWNER: DESCRPTION: DESIGN. CONTAINED SHALL NOT BE USEDTHE S BENEFIT OF ANYONE EXCEPT SOLARCITY INC., FLORES, RYAN FLORES RESIDENCE 51905 AVENIDA RAMIREZ Jarret Hauger • ';; olar ity MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART THE RECIPIENTS OTHERS OUTSCEP ZEP Mighty Hook 6.24 KW PV ARRAY LA QUINTAs CA 92253 MODULES*. (24) KYOCERA # KU2606XPA ORGANIZATION, IN T IN CONNECTION WITH IZ EXCEPTATION, THE SALE AND USE OF THE RESPECTIVE 3055 aeardk:M Way SHEET: REV DATE PV 5 5/13/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARgTY MNG PAGE NAME: (760) 404-8946 THREE LINE DIAGRAM o, CA 94402 T.(650) Son Mate F.(650) 638-1029 (BeB)-SOL-CITY (765-2489) www.solarcity.com ABB # PVI-5000—OUTD—US—Z—A EXISTING ELECTRICAL SERVICE ENTRANCE AND LOAD CENTER 125A 240V 10 100A MAIN BREAKER 100A 2P (E) METER# 1134SR-101390 PROPOSED BI-DIRECTIONAL METER# r—— i 4 ATHiJO/J90YTI :`st7, CTOi 120/=240W4 80:3 - - - - SINGLE PHASE ' UTILITYv ERVICE '.'.,n ELECTRICAL ONE LINE DIAGRAM PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT. SWITCH CUTLER HAMMER # DG221URB 30A, 240VAC -----J----4---------k-4--------------------------------- 2 (1 ) AWG #10, THWN-2, Black (1) AWG #10 THWN-2, Red (1) AWG #10, THWN-2, White (1) AWG #8, THWN-2, Green, EGC — (1) Conduit Kit; 3/4" EMT • Vmp = 240 VAC Imp = 23 AAC r— i AC --————————————————- --------------------------- DC 5000 WATT UTILITY INTERACTIVE INVERTER 120 TO 600 VDC TO 120 /240 VAC 10 ABB # PV1-5000—OUTD—S—US—Z—A J PV ARRAY #1 12 MODULES KYOCERA # - - --KU2606XPA 3120 WATT [ PV ARRAY #1 12 MODULES KYOCERA # KU2606XPA 3120 WATT (I 1 (4) AWG #10, PV WIRE, Black (2) AWG #10, Solid Bare Copper EGC (1 ) Conduit Kit; 3/4" EMT JB -9223414 0 0 CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC Boa NUMBER:RYAN PREMISE OWNER. DESCRIPTION: FLORES, FLORES RESIDENCE 51905 AVENIDA RAMIREZ 6.24 KW PV ARRAY�``,�..�.���� LA QUINTA, CA 92253 PAGE NAME: (760) 404-8946 ONE LINE DIAGRAM DESIGN: Jarret Hau of Jar g �� �.��� �w,,,So1arGty. MOUNTING SYSTEM: ZEP Mighty Hook �";'9!"� Moou�Es (24) KYOCERA # KU2606XPA 3055 Mateo, CA Way Son 1028 F: 94402 )-SOL) 638-105 F:9) w 638-1029 ceeB�—soL—aTy c�Bs-24e91 www.Salaral►y.�„ SHEET: REV. DATE: PV 6 5/13/2015 INVERTER ABB # PVI-5000-OUTD-US-Z-A ELECTRICAL CALCULATIONS CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JWNUMBM. JB -9223414 00 MOUNTING SYSTEM: ZEP Miahty Hook (24) KYOCERA # KU2606XPA INVERTER: ABB # PVI-5000-OUTD-US-Z-A String and 2 Combined Strings 28.75 OCP Size = 30 Module Type: Module Count: (cont = (Amps): Icont * 1.25 = (Amps) Kyocera 260 1000V 24 30 deg C ampacity = 11.36 (cont = (Amps) Branch Circuit Individual MPPT Start ampacity 40 1 strings per Branch A 1 strings per Branch B 12 modules per series string 12 modules per series string (cont * 1.25 = (Amps) String Branch A Branch B Conductor: Conductor: Conductor: (cont * 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 40 40 PV Wire Size: AWG #10 AWG #10 AWG #10 (cont = (Amps) 11.36 11.36 11.36 Start ampacity 40 40 40 Temperature derate (%=F) 0.41 0.41 0.41 Conduit fill derate (%=#) 1 0.8 0.8 Derated ampacity 16.4 13.12 13.12 (cont * 1.25 = (Amps) 14.2 14.2 14.2 Ampacity 40 40 40 Inverter Output Inverter Type: Inverter Count: Total ABB PVI -5000-S AFCI 1 (cont = (Amps): 23 (cont * 1.25 = (Amps) 28.75 OCP Size = 30 Conductor 3: AWG #10 THWN-2 Icont * 1.25 = (Amps) 28.75 30 deg C ampacity = 40 (cont = (Amps) 23 Start ampacity 40 Temperature derate (%=F) 0.91 Conduit fill derate (%_#) 1 Derated ampacity 36.4 (cont * 1.25 = (Amps) 28.75 Ampacity 35 FLORES, RYAN 51905 AVENIDA RAMIREZ LA QUINTA, CA 92253 (760) 404-8946 FLORES RESIDENCE 6.24 KW PV ARRAY PAGE NAME ELECTRICAL CAL Jarret Hauger ,,sOldr0t` , 3055 gearvies Way SHEET: REV. DATE: San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 ATIONS PV 7 5/13/2015 (888)—SOL—CITY (765-2489) www.solarcity.com CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 51905 Avenida Ramirez AC DISCONNECT ....U.TILI.TY • SERVICE INVERTER AND DC DISCONNECT- r ----- ------------ - - - -- - - ISOLAR PHOTOVOLTAIC ARRAYS) l L-------------------------- J PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB -9223414 0 0 MOUNTING SYSTEM: ZEP Mighty Hook MODULES:- (24) ODULES(24) KYOCERA # KU2606XPA INVERTER: ABB # PVI-5000—OUTD—US—Z—A JB -9223414-00 FLORES, RYAN 51905 AVENIDA RAMIREZ LA QUINTA, CA 92253 (760) 404-8946 0 FLORES RESIDENCE 6.24 KW PV ARRAY PAGE WE- SITE AMESITE PLAN PLACARD Jarret Hauger ..,; SolarCity Way . 3055 CIearviee San Mateo, CA 94402 T:(65O) 638-1028 F:(65O) 638-1029 SHEEP REV: DATE PV 8 5/13/2015 (888) -SOL -CITY (765-2489) —sol—ItY- om Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB).. Per Code: CEC 690.17 Label Location: (INV_) Per Code: CEC 690.5(C) Label Location: PHOTOVOLTAIC A(AC) (POI) DISCONNECT Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 WARNING ELEGTRIC,SHOCK HAZARD DO,NOT TOUCH1TERMINALS TERMIN4L�S�ON"BOTH- 1211NEIAND LOAD'SIDES;MAYjBE:ENERGIZED IN THE'OPENIPOSITION Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED CITY OF 1A QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION . DATE BY (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 3055 Clearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set 111 T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE soiaiCiit(888)-SOL-CrrY t (765-2489)wwwsolarci[y.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o V�SolarCity I ®pSolar W,,'zm Zep System for concrete the roofs Next -Level PV Mounting Technology kSolarCity I ® pSolar Components Next -Level PV Mounting Technology Zep 6roove1x 3x 4x Spanner Bar r Cam Foot- ' Part Nos. 850-1400 - 4x _ 850-1399 - 3x .'GrourrdZep — _ 850-1398 - lx 5�anner Bar I f ISpannar Clampl 5 Splice Kit Spanner Clamp � � Part No. 850-1401 art No. 850-1194 Al yr 3 t,, s a Listed to UL 2703 List d to UL 2703 nC is V NMS �,Q 3 OM ICl �•"" Adlusbble Mighty Hook �Q q0�,� Q 33 \ 5 GgMVATj $ — - Description ', a• p�j 0 APV mooning sohtion for concrete file roofs °eMaar� rVViiriis with all Zep Compatible Modules • Auto bonding UL -listed hardware creates structual and electrical bond • Zep System has a UL 1703 Class "A" Fire Rating when installed using V� LISTED modules from any manufacturer certified as "Type 1" or "Type 2" Adjustable Mighty Hook Interlock Cam Foot Part No. 850-1396 Part No. 850-1388. Part No. 850-1413 Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 Om Specifications -. Designed for pitched roofs Installs in portrait and landscape orientations . • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 G __ • Zep System bonding products are UL listed to UL 2703 1) • Engineered for spans up to 72" and cantilevers up to 24" Zep wire management products listed to UL 1565 for wire positioning devices Ground Zep Array Skirt Grip, End Caps DC Wire Clip Attachment method UL listed to UL 2582 for Wind Driven Rain Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf Page: 1 of 2 01 13 15 ZS for Concrete Tile Roofs Cutsheet Rev 02.pdf Page: 2 of 2 Designed for residential and small The wide.input voltage range Highlights. commercial PV installations this. makes theAriverter suftable•to low . I : Power Installations with reduced . - Single phase and split phase output " iriverter;fills;a specific niche in the' grid connection: ABB product line to cater -for those string size. .. - The'transformerless.operation offers Wide input range for increased installations producing between stringing filexi6ility. 5kW and`20kW. high performance efficiencies of up to ' The. high speed an. precise MPPT 97:1% " algorithm offers real time power This inverter includes dual input Free remote monitoring capability tracking and improved energy section toprocess tvvo-strings"with available with every installation. This haniestmg. iildependent:MPPT. enables homeowners to vlevG.thelr energy production and offers. installers - Outdoor NEMA 4X rated enclosure The,hlgh'.speed and precise MPPT for unrestricted use under, any--; / algo h6 "offers real-time power a proactive and economic way_ of ,.. _ maintaining and'troubleshootin the g g environmental conditions '`i" tracking and energy harvesting. . -Integrated DC disconnect switch Flat efficiency curyes.ensure high system. incompliance with international efficiency at all output levelvensuring Standards (-S Version). consistent and stable performance across the entire input voltage and output power range. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. Power and productivity a BOND betterP% for worldr- 2 ABB Solar Inverters I Product Flyer for PVI-5000/6000-TL-OUTD - KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS C� Ky O C E R a KU -60 1 0 0 0 V Z Series • • •Test Cnitins (STC) • • • Cells per module: 60 (6 x 10) STC=1000 eDimensions: 65.43in J 38.98in J 1.57in KU255-6XPA KU260-6XPA6 XPA 60 , .. length/wi&0eight (1662mmJ990mmJ40mm) Weight 47.4lbs (21.5kg) C CUTTING EDGE TECHNOLOGY P^ zss 260 W . 1 As a pioneer with four decades of experience in the V.P 30.8 31.0 V PACKAGING SPECIFICATIONS development of photovoltaic systems, Kyocera drives the IImP 8.28 8.39 A } Modules per pallet 20 market as a leading provider of PV products. We - --- - __ - -- -- demonstrate our Kaizen philosophy, or commitment to va 38.0 38.3 V PallePalletsbox dim 53' nsions: 36 continuous improvement, by setting the industry standard -- - -- -- --- `--- - ---- --" '� lengti box dimensions: (1675 wn/10 in in the innovation of best -in -class solar energy equipment. -- 8.83 9.09 A length/width/height (1675trmJ10o5mmJ1055TT.r,) -0 +5 +5 -0 % Pallet box weight 1060lbs (480kg) Pt l r.nc3 J J QUALITY BUILT IN Nominal Operating Cell Temperature• ' • • 00 • UV -stabilized, anodized aluminum frame in black • . d. SB - •Supported by major mounting structure manufacturers as 45 °c- mmN 1 POTTED NCTIMI • Easily accessible grounding points on all four corners Pm„ 183 187 w 2 � � 1 N for fast installation [v,v 27.7 27.9 v CABLE W/ • Proven junction box technology with 12 AWG PV wire CONNECTOR (_) (+) 6.61 6.71 A LABEL works with transformerless inverters ---- STABILIZER BAR •Amphenol H4-UTX locking plug-in connectors v 34.8 35.5 v provide safe, quick connections Iu 7.15 7.36' A PROVEN RELIABILITY rPTC 228 .3 232.9 w • Kyocera modules confirmed by the Desert Knowledge Temperature Coefficients STABILIZER BAR Australia Solar Centre to have the highest average output of any crystalline module Pm,� 0.45 0.45 %(°c L0 `ZB ' • First module manufacturer in the world to pass long- v,,,P -0.48 -0.48 %J°C term sequential testing performed by TUV Rheinland-"-- -- " T - - - - - - V �P. 0.0 o.oz %_r = ' • Only module manufacturer to achieve the rank of - -- --J -" -- ------ " - _ ---- - -" V� -0.36 -0.36 %J3C 38.98"(9901r1J `� --- ---T -- Research's 2014 PV Module ReliabilityScorecard L% 0.06 0.06 %J°c �� 0 Performance Leader" In all six categories o L CERTIFICATIONS Operating Temp -40 to +90 -40 to +90 °C croon0. 16" Ib13 5135[°° w3^tint Ib13 • UL1703 Certified and Registered, UL Module Fire DesignFRAME CROSS SECTION DIAGRAM Performance: Type 2, CEC Series Fuse Rating 15A u.0 • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 3� I i Maximum DC System Voltage (UL) 1000 V � � � DEI; mVoltaV C `US Hailstone Impact in (25mm) @ 51 mp (23mJs) - i.>e-rss� r.ss•uaw F. 'Subject to simulator measurement uncertainty of +l- 3%. LONG/SHORT 510E STABILIZER BAR 'Oion MPpt\O KYCCERA reserves the right to modify these specifications without notice. NEC 2008 COMPLIANTWARNING: mill Read the instruction UL 1703 LISTED Q na drug. inslallingl8 opery prior a 062614 ing Kyocera Solar modules. OUR VALUED PARTNER 4 I 3 2 I 1 I rr I h .281 (5.5) DIA. KNOCKOUT QUANTITY 1 4 ltl`� z O s a k d p ay. a/serve 4 ID 6.89 (175] 5.73 (145] O O C (CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT NTITY 2 QUANTITY 4 27 f6.81 DIA. 3 MOUNTING HOLES 88 [22] N m B rn NGENTIAL KNOCKOUTS FOR �2, 3/4, 1 CONDUIT )ANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-(/14 COPPER OR ALUMINUM NEUTRAL #4-(j14 COPPER OR ALUMINUM A n+[martxrc ar urox co[raa[rox WARREN SIPE 8 19 98 CUTLER -HAMMER rt s asap mantic[ wu PR758URCH PA m p5G1GYD 0 fnd- R. PROHASKA 8%19/98 DIMENSION SHEET f0� [ON NIOCX R 6 N2�M[0. 30 AMP TYPE 3R GENERAL DUTY 95-1 n SM O�wG A.VL DW xG) SS74DOG 1-2 SS7 n c 95-1445 of 1 2 1 0 n N O Ag ko .281 (5.5) DIA. KNOCKOUT QUANTITY 1 4 ltl`� z O s a k d p ay. a/serve 4 ID 6.89 (175] 5.73 (145] O O C (CENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR 3/4 CONDUIT 1/2, 3/4 CONDUIT NTITY 2 QUANTITY 4 27 f6.81 DIA. 3 MOUNTING HOLES 88 [22] N m B rn NGENTIAL KNOCKOUTS FOR �2, 3/4, 1 CONDUIT )ANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. 2. WIRE RANGE OF LUGS IS AS FOLLOWS LINE AND LOAD LUGS #6-(/14 COPPER OR ALUMINUM NEUTRAL #4-(j14 COPPER OR ALUMINUM A n+[martxrc ar urox co[raa[rox WARREN SIPE 8 19 98 CUTLER -HAMMER rt s asap mantic[ wu PR758URCH PA m p5G1GYD 0 fnd- R. PROHASKA 8%19/98 DIMENSION SHEET f0� [ON NIOCX R 6 N2�M[0. 30 AMP TYPE 3R GENERAL DUTY 95-1 n SM O�wG A.VL DW xG) SS74DOG 1-2 SS7 n c 95-1445 of 1 2 1 Switching Devices Q Safety Switches 8.1 DG32INRB 120/240 Vac General -Duty, Fusible, Single -Throw, continued Maximum Horsepower Ratings 0 • NEMA1 NEMA3R Ampere Fuse Type Single -Phase AC Three -Phase AC OC Enclosure Indoor Enclosure Rainproof System Rating Provision 120V 240V 240V 250V Catalog Number Catalog Number Cartridge Type—Three-Pole, Three -Wire (Three Blades, Three Fuses) -240 Vac b b b 30 — — — — — 0 0 60 0 0 00 — — — — — 0 0 2 200 O 0 400 If — — 50-125 — DG325FGKW DG325FRK(D@ 600 H — 75-200 — DG326FGK 00 OQMFRK00 Cartridge Type—Four-Wire (Three Blades, Three Fuses, S/N)-120/240 Vac 30 H — 1-1/1-3 3-7-1/2 — DG321NGB UG32INRB 60 H — 3-10 7-1/2-15 — DG322NGB OG322NRB 100 H — 7-1/2-15 15-30 — DG323NGB OG323NRB 200 H — 15 25-60 — OG324NGK OG324NRK Ogg H — — 50-125 — OG325NGK DG325NRK 600 H — — 75-200 — DG326NGK DG325NRK OG322URB 120/240 Vac General -Duty, Non -Fusible, Single -Throw Maximum Horsepower Ratings NEMA1 NEMA311 Ampere Single-PheseAC Three -Phase AC DC Enclosurelndoor Enclosure Rainproof System Rating 120V 240V 240V 250V Catalog Number Catalog Number r Two -Pole, Two -Wire (Two Blades) -240 Vac _ I 30 2 3 — — DG221UGB0 DG221URB0 60 3 10 = — OG222UGBr•r DG222URBW q 4 100 — 15 DG223UGB0 DG223URB0 200 — — — — 07 Three -Pole, Three -Wire (Three Blades) -240 Vac d 0 0 30 2 3 7-1/2 — DG321UGBO DG321URB0 1 600 3 15 30 — OG323UGB O DG323URB O 200 — ,15 60 — DG324UGKO OG324URK0 400 — — 125 — OG325UGK0 OG325URK0 600 — — 200 — . OG326UGK0 DG3Z5URK0 Nates O Maximum hp ratings apply only when dual element time delay fuses are used. O Use four -wire catalog numbers below. OSolid neutral bars are not included. Order separately from table on Page 15. r.r WARNINGI Switch is not approved for service entrance unless a neutral kit is installed. W Use three -wile catalog numbers below. 0 Drilled to accept field installed neutral kits. All general -duty safety switches are individually packaged. Accessories are limited in scope on general -duty safety switches. See Page 15 for availability. In addition, clear line shields are available as an accessory on 200-600A general -duty, switches. Catalog Numbers: 20GA= 70-7759-11,400A = 70-8063-8.600A = 70-8064.8. Volume 2—Commercial Distribution CAO8100003E—February 2011 www.eaton.com 27 E:T*N` Powering 8usiness WoMWde" ` '"30A- E)G221URB- r240�. `General Duty Safety Switch 1Interru for a se uridad servicio li ero 2 Pole Non -Fusible Series: aty: polos sin fusibles series: B cant.: MADE IN U.S.A. 09/1W2012 T e 3R Rainproof WHO EN E.U.A. 5591490 (NEMA) Tipo 3R a prueba de LI " 7 82113 12023 2 F 4 D 0 CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR e N 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT N n � M O N •N. E3 m m ID CONCENTRIC KNOCKOUTS FOR TANGENTIAL KNOCKOUTS FOR v1 1/2, 3/4 CONDUIT 1/2, 3/4 CONDUIT n � M o QUANTITY 2 QUANTITY 4 M O N 27 6.8 DIA. N 2.46 (621 3 MOUNTING HOLES w; , u m M 1.01 .88 (221 u 4.75 [ 1211 (261 B TANGENTIAL KNOCKOUTS FOR 1/2, 3/4, 1 CONDUIT QUANTITY 1 NOTE: 1. METRIC DIMENSIONS (IN MILLIMETERS) ARE SHOWN IN BRACKETS. .281[5.5j DIA. 2. WIRE RANGE OF LUGS IS AS FOLLOWS KNOCKO5; LINE AND LOAD LUGS #6-#14 COPPER OR ALUMINUM [46 '.82 [46 QUANTITY 1 .82 u NEUTRAL #4-#14 COPPER OR ALUMINUM 6.10 [1551 A ,E Ma 01 >xs1�� WARREN SPE 8/T'9/98 CUTLER -HAMMER mas mwmmm ,6_T•111 s xm ro ec a usn.PrtrseuDPa - m osa® u¢vr An mm�w- q, pROHISKA 8%19/98 DIMENSION SHEET Pm¢ WR YICCN rt 6 imfOID11E0. "00p °"' 30 AMP TYPE 3R GENERAL DUTY ss-1445.OWC 95-1 m nrm ovec trwim xo.> SS74DGO 1-2 95-14451 of i 3 2 1 0'.. ZepSolar ZS Tile for the roofs ZS Tile`" offers the fastest and least expensive way to install PV arrays on the roofs. It's designed to interoperate with a growing list of Zep Compatible PV modules that incorporate the patented Zep Groove frame specification. Utilizing quarter -turn, rock -in, and drop-in con- nections, ZS the eliminates the need for rails and separate grounding hardware while offering a superior aesthetic approach. Key System Benefits Dramatically reduces installation time Eliminated mounting rails and clip hardware Eliminates separate grounding hardware Rapid, top -accessible precision array leveling Ultra -reliable hyper -bonded grounding matrix Ultra-low parts count Enhanced aesthetics Key Technical Features Low system weight Easily enables additional support at array edges for high wind applications Interlock ETL listed to UL 1703 as ground bond means Ground Zep UL and ETL listed to UL 467 as grounding and bonding device Interlock, Leveling Foot, and Ground Zep listed to UL 2703 as PV bonding device Datasheet: ZS Tile Zep Compatible' ZS Tile mounting hardware is designed for use with Zep Compatibles" PV modules from leading PV module Manufacturers. Visit zepsolar.com for a current list of Zep Compatible'" PV modules. Our Other Product Families 00"Pq I� R o �L LISTED ab"Pw�` Page 1 of 2 Datasheet: ZS Tile Components Interlock 6 y 1>•1 The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -banded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. Leveling Foot I�131.dmm] [3o.2mml —� A- 125in 1.21 in 157.2mmj 139.Amm] 1 2:25in I.SSi, n [al2Un ^� -L 320in L 4.0pin 11010in The leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (125' throw). Array Skirt 00000 The Array skirt facilitates easy front -row installation white providing a clean look at the front of the PV array. Ground Zep E�l dot 10 The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for eve y 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703: Universal Box Bracket The Universal Box Bracket allows rapid attachment of electrical boxes to the module frame. Array Skirt Cap Set The Array Skirt Cap Set provides an aesthetic cover for the exposed end of the Array Skirt- Made of anodized aluminum, each set comes with two Skirt Caps. AC/DC Cable Cllp Clips into Zep Groove for ultra -fast and easy management of PV wiring and micro -Inverter cables. Tools ZepTool:4 functions, I tool; Flat Tool: For inter -module removal. This domment does rot Pate any eaptess wamuty by ten Sohl OF about Its wodua s or Feuds ten Sulu s sole warranty is antained in the Foren Proust warranty lm each Paduu.The ertkser documentation shipped with Zen Saints Poduatsmnstiones tha sale speaiflatknsieteried to in the pteductwmtanty.The customet ksolely tesponsib4lnt mihing the solubility of hpSolai s Pmaoa iP art use Spedrtadmn me Fatten to longe without notice-coppight 012910.11112 ted Sola.Ine U.S. Patent 17,597537, US Pai"11 &109,01& US d hdt Puma Pu94 last Updau: Wary a 7013 3:11 PH Replacement Tile The Replacement Tile provides a means of flashed attachment for ZS Tile installations. Visit "Psobr.com for mote inlmmation shout aur products and Continue. Page 2 of 2 ZS Aero for low -slope & flat roofs .ZS Comp - for composition shingle roofs .ZS Seam" for standing seam metal roofs .ZS Span' for rail -based applications .ZS Trap - for trapezoidal metal roofs .ZS Wave - for corrugated roofs 00"Pq I� R o �L LISTED ab"Pw�` Page 1 of 2 Datasheet: ZS Tile Components Interlock 6 y 1>•1 The Interlock provides north -south and east -west structural and ground bond connections creating a structurally contiguous hyper -banded array. Interlock UL listed to UL 2703 and ETL listed to UL 1703. Leveling Foot I�131.dmm] [3o.2mml —� A- 125in 1.21 in 157.2mmj 139.Amm] 1 2:25in I.SSi, n [al2Un ^� -L 320in L 4.0pin 11010in The leveling Foot provides a means of attachment between the PV array and the mounting surface or flashed attachment apparatus and allows for easy array height adjustment (125' throw). Array Skirt 00000 The Array skirt facilitates easy front -row installation white providing a clean look at the front of the PV array. Ground Zep E�l dot 10 The Ground Zep provides a point of connection between the PV array and the equipment grounding conductor. One Ground Zep is required for eve y 72 PV modules. UL and ETL listed to UL 467. UL listed to UL 2703: Universal Box Bracket The Universal Box Bracket allows rapid attachment of electrical boxes to the module frame. Array Skirt Cap Set The Array Skirt Cap Set provides an aesthetic cover for the exposed end of the Array Skirt- Made of anodized aluminum, each set comes with two Skirt Caps. AC/DC Cable Cllp Clips into Zep Groove for ultra -fast and easy management of PV wiring and micro -Inverter cables. Tools ZepTool:4 functions, I tool; Flat Tool: For inter -module removal. This domment does rot Pate any eaptess wamuty by ten Sohl OF about Its wodua s or Feuds ten Sulu s sole warranty is antained in the Foren Proust warranty lm each Paduu.The ertkser documentation shipped with Zen Saints Poduatsmnstiones tha sale speaiflatknsieteried to in the pteductwmtanty.The customet ksolely tesponsib4lnt mihing the solubility of hpSolai s Pmaoa iP art use Spedrtadmn me Fatten to longe without notice-coppight 012910.11112 ted Sola.Ine U.S. Patent 17,597537, US Pai"11 &109,01& US d hdt Puma Pu94 last Updau: Wary a 7013 3:11 PH Replacement Tile The Replacement Tile provides a means of flashed attachment for ZS Tile installations. Visit "Psobr.com for mote inlmmation shout aur products and Continue. Page 2 of 2