07-1376 (RER)P.O. BOX 1504,
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 07-00001376
Property Address: 52985 AVENIDA RAMIREZ
APN: 773-322-023-13 -000000-
Application description: REMODEL - RESIDENTIAL
Property Zoning: - COVE RESIDENTIAL
Application valuation: 75000
Applicant:.Ale
Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with j
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 531094
Date: y~Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure.is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply Lto an owner of property who builds or improves thereon;
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of.
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.). -
( I I am exempt under Sec. _ , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
YOST DENNIS G
P O BOX 16006
PORTLAND, OR 97.292
Contractor:
SMITH-CONSTR SRVCS INC,
9800 INDIANA AVENUE, STE
RIVERSIDE, CA 92503
(951)354-2276'
Lic. No.: 531094
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 6/14/07
JUN .151007—t1;WU
-
CITY OF u► aril TTA I
-------------------------------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are: .
Carrier STATE FUND Policy Number 229-0035736
1 certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code, I shall forthwith
wicomply with those provisio6s.
Date: �' (S' 01 Applicanl�i� '!
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application. -
1. Each person upon whose behalf this application, is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and. employees for any act or omission related to the work being
performedunderor following issuance of this permit. .
2. Any permit issued as a result of this application becomes null and void if work isnot commenced
within *180 days from date of issuance of such peimit, or cessation of work for 180 days will subject
permit to cancellation. -
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relatingto building construction, and herely authorize representatives
of this county to enter upon the above-mentioned property for inspection p as
Date: _ �' 15 "a7 Signature (Applicant or Ag��
Application Number
07.-00001376
Permit . . .
BUILDING PERMIT.
• Additional desc .
Permit Fee
527.00 Plan Check Fee
342.55
Issue Date
Valuation . . .
75000
Expiration Date
12/11/.07
Qty Unit Charge
Per
Extension
BASE FEE
414.50
?S 00 4.5000
-THOU -'BLDG 50;001 100,'000
112.50
--------------------------
-------------------------------------
-------------
Permit
ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . .
.64.14 Plan Check Fee..
16.04
Issue Date . . . .
Valuation
0
Expiration Date
12/11/07 ,
Qty -Unit Charge
Per
Extension
BASE FEE
15.00 '
1404.00 _.0350
ELEC NEW RES - 1 OR 2 FAMILY
49.14
------------------------------------------------------------------------
Permit . . .
MECHANICAL
Additional desc .
Permit Fee
42.00 Plan Check Fee ..
10.50
Issue Date . . . .
Valuation . . .
0
Expiration Date
.12/11/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA MECH APPL REP/ALT/ADD
91.00
1.00 9.0000
EA, MECH B/C <=3HP/100K BTU
9.00
Permit. . . .PLUMBING
Additional desc
Permit Fee . . . .
22.50 Plan Check Fee
5.63
Issue Date
Valuation _
-0
. Expiration Date
12/11/07
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1:00 7.5000.
EA PLB WATER .HEATER/VENT.
7.50 .
Special Notes and Comments
INSTALL NEW TRUSSES OVER GARAGE,REPAIR
•
LQPERMIT
F
-LQPERMIT
Application Number
. . . . .
07-00001376
-- - - - --
Special Notes and
Comments
DRYWALL ELEC. AND
MECH.-DUE TO
FIRE
DAMAGE.
Other Fees . . .
. . . . .
ENERGY REVIEW
FEE
34.26
STRONG MOTION
(SMI) - RES
7.50
Fee summary
Charged
Paid
Credited
Due
Permit Fee Total
655.64
.00
.00
655.64
Plan Check Total
374.72
.00
00
374.72
Other Fee Total
-41.76
.00
.00
41.76
Grand Total
1072.12
.00
..00
1072.12
Bin # r,%
City of La Quinta
Building 8X Safety Division
P.O. Box 150.4, 78-495 Calle Tampico
La-Qpinta, CA 92253 - (760) 777-7012
-Building Permit Application and Trackin-g, Sheet
Permit
Project Address:' St 189' A\JjW% DA tQ a nq C I Z
Owner's Name:
A. P. Number:
Address:
Legal Description:
Contractor: in�rrCod -s -re-.j c --r a,4 1N
Address:. $t& t,�o#AiA '.Adc* SJ #-r<_
City, ST, Zip: LA 7_7 .-S
Telephone:
Project Description:
City, ST, Zip:. C
Telephone:
State Lic. #: S 31 o 5 4
City Lic. #:
LI\JA(-L
Arch., Engr., Designer:
Address:
City, ST, Zip:
Telephone:
State Lic. #:
Name of Contact Person: V -,e -v- In C)0
OF
Construction Type: Oecup y:
Project'type (circle one): New Add'r. Alter. —Re—pair--
))emo
Sq. Ft.:
T# Stories:.
# Units:
Telephone # of Contact Person: 1151:S -;g S .r dt-L>
Estimated Value of Project: 757, ac;
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Recd
TRACIUNG.
PERMIT FEES
Plan Sets
Plan Check submitted 67
Itein
Amount
Structural Cafes.
1_2
Reviewed, ready rec s
�o C60 t! 0)
Plan Check Deposit
Truss CaIcs.
of
Called Contact Per
Plan Check 3alance
Energy Cafes.
Plans picked up Woo
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correcti T_(Srissue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up'
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN-HOUSE:-
Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permi.1 Fees
s (t
kR_
' TITLE 24 REPORT
Title 24 Report for:
Fire Damage Restoration -'Yost Residence
52985 Avenida Ramirez
La Quinta, CA 92253
Project Designer:
Helfrich Associates .
30640 Kristin Court
Redlands, CA 92373
(909) 389-7326
Report Prepared By:
Vincent Miranda
A.D.E. Consulting
370 W. 6th Street, Suite 210
San Bernardino, CA 92401
(909) 884-9484
CITY OF LA QUINA
BUILDING & SAFETY DL umber:
APPROVED 217-R
FOR CONST CTION
DAT
ate:
3/22/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC- www.energysoft.com.
EnergyPro 4.3 by EnergySoft Job Number. 2917-R User Number. 3854
TABLE OF CONTENTS "
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 7
Form WS -5R Residential Kitchen Lighting 9
Certificate Of Compliance:
Residential
❑ Addition
(Part 1 of 4) CF -1 R
-tee namaqe Restoration
Project Title
Avenida Ramirez
- YostRes.idence
I a Qiflnta
Building Front Orientation:
(E) 90 deg
'x/22/2007
Date
_52985
Project Address
Natural Gas
Fenestration:
Building Permit #
A-D-F-C:onsidtina
187 ft2
Avg. U: 0.72
(909) 884 -9484
-
Documentation Author
INFORMATION
Telephone
Plan Check/Date
-_i`wPro
Compliance Method
15
Climate Zone
Field Check/Date
TDV
Standard
Proposed Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating
2.57
2.01
0.56
Space Cooling
99.77
89.44
10.32
Fans
13.40
12.71
0.68
Domestic Hot water
14.49
13.18
1.31
Pumps
0.00
0.00
0.00
Totals
130.22
117.35
12.87
Percent better than
Building Type:
Single Family
❑ Addition
❑ Multi Family
[J Existing + Add/Alt
Building Front Orientation:
(E) 90 deg
Fuel Type:
Natural Gas
Fenestration:
Area:
187 ft2
Avg. U: 0.72
Ratio:
13.3% Avg. SHGC: 0.68
BUILDING ZONE
INFORMATION
Zone Name
HVAC Rysfam Replace,
Floor Area Volume
1404 1a n4nn4n
OPAQUE SURFACES Insulation Act.
Type Frame Area U -Fac. Cay. Cont. Azm. Tilt
Wall Wnnd 301 X02 R_13 R -n n An gn
Wall Wnnd 437 0.102 R_13 R_0"0 180 gn
nnnr None 20 n.5oo None R-0.0 180 A0
Wall Wnnd 322 Q109 R_13 R-0 0 27n An
Wall Wnnd 488 0.102 R_13 R_0-0 Q 90
nonr None 18 ' n_Soo None R-0.0 _0 go
Rnof Wnnd 1 4n4 n_n2r, R_38 R -O n _gn n
Total Conditioned Floor Area:
Existing Floor Area:
Raised Floor Area:
Slab on Grade Area:
Average Ceiling Height:
Number of Dwelling Units:
Number of Stories:.
# of Thermostat
Units Zone Type Type
1 nn Conditioned Setback
1,404 ft2
1,404 ft2
0 ft2
1,404 ft2
10.0 ft
1.00
Vent
Hot. Area
Gains Condition
Y / N Status JA IV Reference Location / Comments
Run Initiation Time: 03/22/07 09:51:56 Run Code: 1174585916
EnergyPro 4.3 by Energysoft User Number. 3854 Job Number. 2917-R Paae:3 of 9
Certificate Of Compliance: Residential (Part 2 of 4) CF -1 R
Fire Damage Restoration - Yost Residence 3/22/2007
Project Title Date
FENESTRATION SURFACES
True Cond.
# Type Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Type
Location/
Comments
J__
2
Window
Window
Front
Left
(F)
(S)
-'A3 3
20.0
0.590 116 -A -A 0.6.5 116_R qp_ qa Fxic ino Double Nnn Metal Clear
0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear
1ct Floor
1st Floor
3
Window
Left
(S)
12.0
0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear
1st Floor
4
Window
Left
(S)
30.0
0.790 116-A 0_70 116-B 180 90 Existing Double Metal Clear
1st Floor
5
Window
Left
(S)
33.3
0.580 116-A 0_65 116-B 180 90 Existing Double Non Metal Clear
1st Floor
6
Window
Rear
(W)
12.0
0.790 116-A 0_70 116-B 270 90 Existing Double Metal Clear
1st Floor
L
Window
Right
(N)
10.0
0_790.116-A.0_D 116-B _Q 90 Altered Double Metal Clear
1st Floor
8
Existing
Area Thick. Heat Inside
0.790 116-A 0_70 116-B Double Metal Clear
pre -altered for above
6
Window
Right
(jw
16.0
0.790 116-A 00.70 116-B _0 90 Existing Double Metal Clear
1st Floor
-M
Window
Right
(jy)
20.0
0.790 116-A 0_70 116-B 0 90 Altered Double Metal Clear
1st Floor
11
Existing
0.790 116-A 0_70 116-B Double Metal Clear
pre -altered for above
Condition
Loc_3tion/
Type Length R -Val. Location
JA IV Reference
Status
Conments
Slab Perimeter 134 None No Insulation
26-A1
Existing
1st Floor
1. Indicate source either from NFRC or Table 1169 2. Indicate source either from NFRC or Table 1166.
INTERIOR AND EXTERIOR SHADING Window
Overhang
Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd.
Len. Hgt. LExt. REA.
Dist. Len.
Hgt. Dist. Len. Hgt.
1 Bug Screen 0.76
2 Bug Screen 0.76
3 Bug Screen 0.76
4 Bug Screen 0.76
5 Bug Screen 0.76
6 Bug Screen 0.76
7 Bug Screen 0.76
9 Bug Screen 0.76
10 Bug Screen .0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside
Condition
Location/
Type (sf) (in.) Cap. Cond. R -Val.
JA IV Reference
Status
Comments
PERIMETER LOSSES Insulation
Condition
Loc_3tion/
Type Length R -Val. Location
JA IV Reference
Status
Conments
Slab Perimeter 134 None No Insulation
26-A1
Existing
1st Floor
Run Initiation Time: 03/22/07 09:51:56 Run Code: 1174585916
EnergyPro 4.3 by EnergySoft User Number. 3854 Job Number. 2917-R Page:4 of 9
Certificate Of Compliance:
Residential
(Part 3 of 4)
CF -1 R
• Fire Damage Restoration - Yost Residence
Project Title
Water Heater
3/22/2007
Date
HVAC SYSTEMS
Heating
Location Type
Minimum
Eff
Cooling
Type
Minimum Condition
Eff Status
Thermostat
Type
HVAC System Replaced Central Furnace
80% AFUE
Split Air Conditioner
13.0 SEER Altered
Setback
pre -altered for above Central Furnace
80% AFUE
Split Air Conditioner
10.0 SEER
Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
HVAC System Replaced Ducted Ducted Attic 8.0 New Yes
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick. ,
WATER HEATING SYSTEMS
Rated
Tank
EnergyTank
Insul.
Water Heater
# in Input
Cap. Condition Factor
Standby. R -Value
System Name Type Distribution
Syst. (Btu/hr)
(gal) Status
or RE
Loss (%) Ext.
General Electric GG50T6TA Small Gas ' No Pipe Insulation
1 40,000
50 Altered
0.62
n/a n/a
n/a n/a
_Standard Gas 50 gal or Less Small Gas pre -altered for Aboy
1 40,000
50
OL57
Multi -Family Central Water Heating Details
Hot Water Pump
Hot Water Piping
Length (ft)
Add 112"
Control # HP Type
In Plenum Outside Buried
Insulation
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insolation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Title/Firm: Helfrich Associates
Address: 30640 Kristin Court
Redlands CA 92373
Teleph 909 3L9-73261 Lic. #: C4,00
3
(signa re) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
(signature) (date)
Documentation Author
Name: Vincent Miranda
Title/Firm: A.D.E. Consultinq
Address: 70 W. 6th Street Suite 210
k
ernardi 92401
Tele 0
Z �7
(sign ture) (date)
Certificate Of Compliance: Residential (Part 4 of 4) CF -1 R
Fire Damage Restoration - Yost Residence 3/22/2007
Project Title Date
Special Features and Modeling Assumptions .
The local enforcement agency should pay special attention to the items specified In this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local enforcement
aaencv determines the adeauacv of the iustification_ and may refect a buildina or design that otherwise complies based on the
idequacy of the special justification and documentation submitted.
Plan I Field
HERS Required Verification
Items in this section require field testing and/or verification by a certified home energy rater under the supervision oft CEC-
approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4F Plan Field
installation certificate.
The HVAC System "HVAC System Replaced" incorporates HERS verified Duct Leakage. Target leakage is calculated and
documented on the CF -4R.
EnergyPro 4.3 by EnergySoft User Number. 3854 Job Number. 2917-R Paae:6 of 9 1
Mandatory Measures Summary: Residential (Page 1 of 2) MFA R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach usec. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mardatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes'or check NA if not applicable and Included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
�§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
E
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
�§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑x
❑
appy to exterior mass walls).
❑
❑
❑
*§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox
❑
❑
❑
b. outside air intake with damper and control, flue damper and control
❑
❑
❑
2. No continuous burning gas pilot lights allowed.
❑
❑
❑
§ 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑
El
§ 150(g)i Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
❑
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
perneance rate no greater than 2.0 perminch.
§ 118:. Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑x
ElCF-6R
Form:
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Door; and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑x
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
❑
❑x
❑
Coefficient (SHGC), and infiltration certification.
3.> Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
0
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
❑X
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
❑x
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than.0.58 must be'extemally wrapped with insulation
❑
0
❑
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
0
❑
length of recirculating sections of hot water pipes shall be insulated to Table 1508.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A-
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture,- equipment maintenance,
❑ .
ER
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
0
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.3 by EnergySoft User Number. 3854 Job Number. 2917-R
Page:7 of 9
Mandatory Measures Summarv: Residential (Page 2 cf 2) MFA R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated
into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 60,;, ❑ ❑X ❑
605, and Standard 65; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other ducl-closure system
that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than
❑
2
❑
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
7. Flexible ducts cannot have porous inner cores.
❑ 2 ❑
support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
reductions in the cross-sectional area of the ducts.
2. System is installed with:
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
2
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ 2 ❑
4. Exhaust fan systems have back draft or automatic dampers.
❑
2
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
2
❑
dampers.
electric and have an output frequency no less than 20 kHz.
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑ 2 ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannot have porous inner cores.
❑ 2 ❑
§ 114: Pool and Spa Heating Systems and Equipment
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑ ❑ ❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑ ❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑ ❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑ ❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ 2 ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑ ❑
Lighting Measures
§ 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ 2 ❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Wafts or greater are
electric and have an output frequency no less than 20 kHz.
§ 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ 2 ❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ 2 ❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luriminair s,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages; laundry rooms, utility rooms shall be high efficacy luminaires.
❑ ❑X ❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). ,
§ 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms,garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are
❑ 2 ❑
controlled by an occupant sensor that complies with Section ll 19(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ 2 ❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑ 2 ❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article
680 locafions) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d)-
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑ ❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑ ❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section
119(d).
EnergyPro4.3 by EnergySoft User Number. 3854 Job Number: 2917-R
Paae:8 of 9
-Residential Kitchen Lighting Worksheet WS -5R
Fire Damage Restoration -Yost Residence 3/22/2007
Project Title Date
At least 50% of the total rated wattage of permanently Installed luminaires in kitchens must be In luminaires that are high efficacy luminaires
as defined In Table 150-0. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts. Other Watts
(2) 4 It Fluorescent T8 Rapid Start Elec Yes X No -F-1 62.0 x 1 = 62 or.
60w Surface Mount Incandescent Yes No X 60.0 x 1 = or 60
Yes No x - or
Yes No x = or
Yes No x or
Yes No x = or
Yes No x _ or
Yes No x = or
Yes No x = or
Yes No x or
Yes No x = or
Yes No x = or
Yes I No x = or '
Yes No x - = or
Yes No x = or
Yes No x. = or
Yes41__No x = or '
Yes x = or
Yesx = or
Yes x = or
Total A: 162 B: 60
COMPLIES IF A;-* B YES ® NO ❑