Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BSOL2015-0073
ti LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 oftBusiness and Professions Code, and my License is in full force and effect. License CI ss: C4 B C10 A Licensq 0Date Contractor OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that l am exempt from Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or'repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division ? of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5'by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I 1 am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compe tion, as provided for by Section 3700 of the Labor Code, for the performance th for which this permit is issued. have and will maintain workers' com-Densation insurance, as required by S ti r 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree th f I should become subject to the workers' compensation provisions ofSe 7 of abor Code, I shall forthwith comply wit tho provisions. J Date:i Applican ! WARNING: FAILURE TO SECURE WORKERS' COMF'ENSATI COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI AND CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the'Eiuilding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellaton. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordiAAAgennf te la elating to building construction, and hereby authorize representat ent r upon the above- mentione pro 6yfor inspection purposes.j Date:' Signature (Applicant C� O�i � - VOICE (760) 777-7125 78-495 CALLE TAMPICO D -` FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT t Date: 6/10/2015 Application Number: BSOL2015-0073 Owner: Property Address: 53180 AVENIDA RAMIREZ THEODORE HANE APN: 774052009 53180 AVENIDA RAMIREZ Application Description: HANE / (25) ROOF MOUNTED SOLAR PANELS (1) INVERTER 6.5 KW LA QUINTA, CA 92253 z Property Zoning:. n C_ ApplicationValuation: $14,365.00• 6 Z a -n Applicant: Contractor: C SOLARCITY CORPORATION SOLARCITY CORPOFATION o C G7 3055 CLEARVIEW WAY 3055 CLEARVIEW 61.AY n ATTN ZOE STEELE ATTN ZOE STEELE SAN MATEO, CA 94402 SAN MATEO, CA 94402 (650)963-5630 Llc. No.: 888104 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 oftBusiness and Professions Code, and my License is in full force and effect. License CI ss: C4 B C10 A Licensq 0Date Contractor OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that l am exempt from Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or'repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division ? of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5'by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I I 1 am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compe tion, as provided for by Section 3700 of the Labor Code, for the performance th for which this permit is issued. have and will maintain workers' com-Densation insurance, as required by S ti r 0 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree th f I should become subject to the workers' compensation provisions ofSe 7 of abor Code, I shall forthwith comply wit tho provisions. J Date:i Applican ! WARNING: FAILURE TO SECURE WORKERS' COMF'ENSATI COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTI AND CIVIL FINES UP TO. ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the'Eiuilding Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellaton. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordiAAAgennf te la elating to building construction, and hereby authorize representat ent r upon the above- mentione pro 6yfor inspection purposes.j Date:' Signature (Applicant FINANCIAL . tr h ` _ ;,ACCOUNT �" �s`'1 '.QTY �' AMOUNT{ t #PAID,Y PAIDDATE ,w+�k , {'DESCRIPTION` BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 BYE:RECEIPT# CHECK# CITDBY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00. $0.00 <E8�,'DESCRIPTION`ACCOUNT AMOUNT �' ' PAID` PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 s, + PAID#BYi: � <° -METHOD �` r` x RECEIPzT #np CHECK #ate a CLTD BY x �•, J„ uDESCRIP,TION ' X. t b ACCOUNT IQTY4 " AMOUNT } _ PAID � *�A ' PAIU DATE yw 3. �:.X L. < 4 .. C PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600. 0 $24.11 $0.00 :P `PAID WE.METHOD x� RECEIPT # Y CLT BY '3 ,� x _i Total Paid for ELECTRICAL: $48.34 $0.00 ° ACCOUNT �i A(VIOUNT�= PAID DATE:. h'rDESCRIFTION$l a .QTY# MPAID: PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Ss PAID BY` METHODt£., ` �" # CHECK # £ CLTD BY, ,v �` ,';RECEIPT 5 Total Paid forPERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 I Description: HANE / (25) ROOF MOUNTED SOLAR PANELS (1) INVERTER 6.5 KW Type: SOLAR Subtype: Status: APPROVED Applied: 6/8/2015 SKH Approved: 6/9/2015 JFU Parcel No: 774052009 _ Site Address: 53180 AVENIDA RAMIREZ LA QUINTA,CA 92253 Subdivision: SANTA CARMELITA VALE LA QUINTA Block: 219 Lot: 16 Issued: UNIT 21 >. Lot Sq Ft: 0' Building Sq Ft: 0 Zoning: Finaled: Valuation: $14,365.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 6.5 kW SOLAR ARRAY - (25) 255W KYOCERA KU2606XPA PANELS W/ (1) ABB PVI-6000-OUTD-US-Z-A INVERTER + MAIN SERVICE PANEL UPGRADE TO 125A W/ 100A MAIN BREAKER [450SF] 2013 CALIFORNIA ELECTRICAL CODE. 4, 5-�, , I APPIiEd to Approved J Printed: Wednesday, June 10; 2015 1:28:03 PM 1 of 2 SYSTEMS CHRONOLOGY CHRONOLOGYTYPE " 3;` STAFF NAME ACTION DATE < COMPLETION DATE NOTES >. NOTIFIED ELENA LOYA W/ SOLAR CITY E-MAIL JAKE FUSON 6/9/2015 6/9/2015 (ELOYA@SOLARCITY.COM) THAT PLANS WERE APPROVED AND PERMIT WAS READY TO ISSUE. PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 6/8/2015 6/8/2015 RECEIVED . . CONDITIONS CONTACTS NAMETYPE NAME` 'CITY`:, iSTATE ZIPS', PHONE -',"7T Is; FAXEN` EMAIL, w� .._s�,ADDRES51 APPLICANT SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 .(760)333-3712 mplasse@solarcity.com CONTRACTOR SOLARCITY CORPORATION 3055 CLEARVIEW WAY SAN MATEO CA 94402 (760)333-3712 mplasse@solarcity.com OWNER THEODORE HANE 53180 AVENIDA LA QUINTA CA 92253 (760)333-3712 RAMIREZ Printed: Wednesday, June 10; 2015 1:28:03 PM 1 of 2 SYSTEMS ,. 2.1 FINANCIAL • a r 74 CL DESCRIPTIQN'' .' ;',ACCOUNT „,. ,,� QTY 'AMOUNT F � PAID a ' "PAID DATE r >µRECE1PT # CH.ECK #t; METHOD : PAID BY rvD„e ` , a.- - s 3 , R , B 05A5 501473 FCC 101-0000-20306 0 $1.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $1.00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 - PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:$0.00 SEQID.j'. INSPECTIONTYPE '.` INSPECTOR w` SCHEDULED .COMPLETED RESULT :`-. REMARKS NOTES &. ' DATE SOLAR FINAL"* BLD PARENT PROJECTS,___.'-, Printed: Wednesday, June 10, 2015 1:28:03 PM 2 of 2 sysTrMs Bfn.# City Of Ld QU(n1ta Building 8r Safety DhMon P.O. Box 1504, *78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: R Owner's Name:. - A. P. Number: Address: M Z Legal Description: City, ST, Zip: La Quinta, CA Contracto, Solar CityTelephone: �'✓ ,� Address: 3055 Clearview Way. PmjectDescription: �55 roof moun•-ed solar panels . city, ST zip: Sian Mateo, CA, 94402 -inverter(s)_ Telephone:650-638-1028 "'Cityuc, r% StateLic.#: 888104 c Arch, &U., Designer. 4- Address: City,ST Zi Telephone: Construction Type:. OccLpancy: State Lia#: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Elena Loya Sq. Ft.: # Stories: # Unit;: Telephone # of Contact Person: (442.)256-1134 Estimated Value of Proj APPLICANT: DO NOT WRITE BELOW THIS UNE 0 Submittal Req'd Recd TRACMG �PERIMT FEES Plpn Sets Plan Cheek submitted Item Amount Structural Calcs. Reviewed, ready for wammdaits ( SS iZ 61q Plan Check Deposit. . Truss Coles. Called Contact Person L Plan Check Balance. Title 24 CaW6 Plans picked up Construction Flood plain plan Pians resubmitted Mechanical Grading plan Z'! Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN ROUSE:- ''" Review; ready for correctiooslissae Developer Int-pact Fee Planning Approval Called Contact Person A.LP-P- Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees t ABBREVIATIONS ELECTRICAL NOTES ' JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERIIED VIA A ALL CONSTRUCTION SHALL COMPLY WITH THE 2013 AC ALTERNATING CURRENT - , . UL—LISTED POWER—CONDITIONING INVERTER. CALIFORNIA BUILDING, RESIDENTIAL, MECHANICAL, BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. ELECTRICAL, PLUMBING, ENERGY, AND GREEN. CONIC CONCRETE 3: A NATIONALLY—RECOGNIZED TESTING BUILDING CODES AND THE LA QUINTA MUNICIPAL DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN- . - CODE EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH -ART. 110.3. ' •• _ ' (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING V ' �� rv`' EMT ELECTRICAL METALLIC TUBING _ MEANS MAY BE ENERGIZED IN THE OPEN POSITION, F' , FSB FIRE SET -BACK A SIGN WILL BE, PROVIDED WARNING OF THEA - - ;� . GALV GALVANIZED HAZARDS PER ART. 690.17. ± ' GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE ` r ,- • �, GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED • PHASE AND SYSTEM PER ART. 210.5. _ _ _ • _ CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL,' Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT, 7. \ DC CONDUCTORS EITHER DO NOT ENTER kVA . KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR Z' •`' CITY.OF LA QUINTA kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). j .' ,'.BUILDING & SAFETY DEPT. MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN;R'`APPROVED$ (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL . - . UL LISTING. ' { _ FOR'CONSTRUCTIONI NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE - ,� ' F DATE6 9 M5sy PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. t PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE. SCH SCHEDULE _ BONDED WITH EQUIPMENT GROUND CONDUCTORS. l S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL . UPS UNINTERRUPTIBLE POWER SUPPLY. ' V VOLT Vmp VOLTAGE AT MAX POWER ! . Voc VOLTAGE AT OPEN CIRCUIT' VICINITY MAP INDEX'- - W WATT PV1 COVER SHEET 3R NEMA 3R, RAINTIGHT` ' L PV2 SITE PLAN- . PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES =u k L PV5 THREE LINE DIAGRAM t�.• P ECTRICAL CALCULATIONS . 1. ALL WORK TO BE DONE TO THE 2013 - J X i. PV E LINE DIAGRAM CA C 8808104 . . CALIFORNIA BUILDING CODE AND THE 2013 t s • Cltheets Attached r '� CALIFORNIA RESIDENTIAL CODE. " 4 t - 2. ALL ELECTRICAL WORK SHALL COMPLY WITH � ; • - x '„, • THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY t f THE 2013 CALIFORNIA ELECTRIC CODE. - MODULE GROUNDING METHOD: ' ZEP SOLAR �• • "REV BY DATE COMMENTS , AHJ: La Quints R ME DATE COMMENTS . O UTILITY: Imperial Irrigation District. _ PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL —,THE INFJOB CONTAINED SHALL NOT BERUSED OR THE NUMBER J g-9223524 00 HANE, TED HANE RESIDENCE' . Hanh Nguyen 41111;BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'!l SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTile 53180 AVENIDA RAMIREZ 6:5 KW PV ARRAY - - ��� e PART TO OTHERS OUTSIDE THE RECIPIENTS M�DLE� LA QUINTA, CA 92253 ORGANIZATION, EXCEPT IN CONNECTION WITH r r THE SALE AND USE OF THE RESPECTIVE (25) KYOCERA -# KU2606XPA APN: 774052009 r 3055 Mateo, CAN Way PAGE NAME •� SHEET. — ATE: Say Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650) 638-1028 - F.(650) 638-1029 PERMISSION OF SOLARCITY INC. ABB PVI-6000—OUTD—US—Z—A (.760) 333-3712 �' COVER SHEET PV 16/4/2015 (BN)-SOL-aTY (765-2489) www.sIarcity.�, ar j CITY OF LA QUINTA UILD:IN.G & SAFETY DEPT. Al ��IIU�RPRl YA 5 3-c 3CI N . _ F _�C ,NST_R6C;T1ON� _, 1�l �. qqr �DATE�. ►<li.JilwW...y..>. TRANSFORMER INFORMATION: KVA PHASE HIGH KV LOW 120/240V —METER# 1134SORD-115315 "PROPOSED BI—DIRECTIONAL METER#----_-------" *DISCONNECT—BRAND—MODEL — AC DISCONNECT: Cutler Hammer 3 FT FROM MAIN PANEL — INVERTER: ABB PVI-600—OUTD—US—Z—A �4'N oli lay CONFIDENTIAL —THE INFORMATION HEREIN JOB NUMBER: J E u & WARNING LABELS CONTAINED SHALL NOT BE USED FOR THE © MOUNTING SYSTEM: [MODULES: BENEFIT OF ANYONE EXCEPT SOLARCITY INC., AC DISCONNECT & WARNING LABELS NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENYS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ZEP ZS Tile (25) KYOCEI SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER: ABB # PVI - F3 0 a� a 0 00 ro Ln Front Of House (E) DRIVEWAY 20QA, 240V, SINGLE PHASE, 2 �VVgR S, 22kAiC EX.I TING BI DIRECTIONAL Iu�E . Q 1B4SORD-115315 92-223524 00 P, kTile► Aff KU2606XPA 000,'OUTD—US—Z—A tv'' 31 F I PREMISE OWNER: HANE, TED 53180 AVENIDA RAMIREZ LA QUINTA, CA 92253 (760) 333-3712 PU M P 1 3' 0 --TSI HANE RESIDENCE 6.5 KW PV ARRAY PAGE NAME- SITE AMESITE PLAN Inv I©I lO PITCH: 18 ARRAY PITCH: 18 MPl AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W -Tile STORY: 1 Story I pr-I~nin Q (E) UTILITY METER & WARNING LABEL lay INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS FAC AC DISCONNECT & WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS Q DISTRIBUTION PANEL & LABELS Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER O STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR GATE/FENCE O HEAT PRODUCING VENTS ARE RED r, I% ; l INTERIOR EQUIPMENT IS DASHED L_J SITE PLAN N Scale: 1/8" = 1' W E 0 1' 8' 16' S DESIGN: Hanh Nguyen Alq y �,;SolarCit . SHEET: REV: PV 2 DATE: 3055 CIeaNew Way Son Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 6/4/2015 (888)—SOL—CITY (765-2489) www.solarcity.com A SIDE VIEW OF MP1 NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES r - a TOP CHORD 2X4 @, 24" OC BOT CHORD 2X4 @24" OC A SIDE VIEW OF MP1 NTS MPI X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 48" 24" - PORTRAIT 48" 19" TOP CHORD 2X4 @, 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 180, PITCH 18 STORIES:,1 , ARRAY AZI 180 PITCH 18 Low Profile W -Tile r r CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9223524, 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM:. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP ZS Tile WTile PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION MATH THE SALE AND' USE OF THE RESPECTIVE MODULES (25) KYOCERA # KU2606XPA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-6000-OUTD-US-Z-A (E) 2x4 " DIA THREADED STUD & NUT ZEP LEVELING FOOT ZEP TOP ARM ZEP ANTI -ROTATION PLATE M10 BOLTS �. MOUNTING BASE (E) TILE _ (E) ROOF DECKING (E) RAFTER " DIA STAINLESS STEEL LAG BOLT (2-j" EMBED, MIN) • , .- S1 STANDOFF Scale: 1 1/2" = 1' { PREMISE OWNER: DESCRIPTION: HANE, TED HANE RESIDENCE 53,180 AVENIDA RAMIREZ 6.5 KW PV ARRAY LA QUINTA, CA 92253 PAGE NAME- (760) AME(760) 333-3712 STRUCTURAL VIEWS INSTALLATION. ORDER REMOVE TILE, LOCATE & MARK (1) RAFTER LOCATION.PLACE STANDOFF BASE & DRILL PILOT HOLES. 2) CLEAN PAPER AROUND PILOT HOLE. SEAL PILOT HOLES AND BOTTOM OF ' (3) STANDOFF WITH POLYURETHANE SEALANT. 4) LAG STANDOFF. BASE INTO RAFTER. 5 PLACL FLASHING AND ATTACH ) SEALING SPACER WITH SINGLE BOLT. PLACE ZEP BAR: THEN INSTALL (6) LEVELING FOOT WITH BOLT & WASHER. f r 1 DESIGN: Hanh Nguyen i,solarCit e 3055 CleoNew Way SHEET. REV. DATE Son Mateo, CA 94402 T:(650) 636-1028 F:(650) 638-1029 PV 3 6/4/2015 (666) -SOL -CITY (765-2469) ,w,.solarp►y.com UPLIFT CALCULATIONS 06.04.2015 -�So�arCit . PV System Structural Version #46.4 x .11, Desian Software JOB NUMBER: JB -9223524 00 Project Infarntation & Table Of Contents Risk Category_:_ MOUNTING SYSTEM: ZEP ZS Tile Wipe Ii 53180 AVENIDA RAMIREZ 6.5 KW PV ARRAY LA QUINTA CA 92253 PV System Type - SolarCity SleekMounE"" EXCEPT IN ON ORGANIZATION, EXCEPT IN CONNECTION WITH IZ Spanish Tile Roof' _ - - - Spanish Tile Roof - - - -- - - THE SAIF AND USE OF THE RESPECTIVE L ers of Com Roofin PAGE HAMS SHEET: REV. DATE Roof Slope -Spacing PERMISSION OFITY ISOLARCITY INC. PMENT. WITHOUT THE WRITTEN 180 PV 4 5/4/2015 Rafter 24" O.C. PV System Module Orientation Landscape and Portrait PV Module Area 443 sf PV Module. Width - - 39" - -- Pv Module Length _ -- - _ _ _ - _ _ 65"- Standoff Attachment Hardware SM Tile Reduced Ground/Roof Live/Snow Loads Ground Snow Loa - Pg _-` 0.0 PS ASCE Table 7-1 —_ _-- --- - - -f-- - - _ 0.0 PSf - - - - -- Surrounds _ -- ng Roof Snow - - ASCE Eq: -- -1 Roof Snow Over PV Modules 0.0 ASCE Eq:' 7,4-1 Wind Design Criteria Wind Design Code ASCE 7-10 Wind _Design_M_ethod ____ __ Partially/FullyEpdosed Method Basic Wind Speed_ _ V _-- __- 110 mph _ Fig. 26.5-1A___. Exposure Category _ _ - _ _ --_-- -- _ _ _-_------ - -_ Section 26:7__._ Roof Style _ ^_ _ -- __-- --- Gable Roof 89.30.4-2A/B/c-5A/e Mean Roof Height _ h _ _ _ 15 ft Seddon26.2 Effective Wind Area 1 Module A 17.7 sf _ IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure 0.85 Table 30.3-1 Topographic Factor _ _- -__ _ _ _Kz, Krt _ _ _ l.b� Seddon 26.8__ _ _ Wind Directionality Factor - - Kd_ - - _ _ _ _ _ _-_ _ _ 0.85 Section 26.6-1_ Im ortatim Eador I NA Velocity Pressure qh qh = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 psf Equation 30.3-1 Ext Pressure Coeffident (Up)_ __ _ ____ GC (Up)„__ 088 x0.30.4-2.A/e/c-5A/e Ext. pressure Coefficient Down G Down 0.45 Fg.30.4-vt/s/C-5A/e Design Wind Pressure P p= h GC Equation 30.4-1 Wind _Pressure Up -- - - -- - _ R(qP) ----- -- - - - -- 1% psf --- -- -- Wind Pressure Down down 16.0 psf Allowable Standoff Spacings kDirection Y=Dfredion Max Allowable_ Standoff Spacing_--- Landscap_e _ 39" Max Allowable Cantilever----_--- - _ -- Landscape - _--72 -�---_-__-- -----------_-_--- 24” _-___-- -- _--- -- ---, _ ---__NA-- _ Standoff Configuration Landscape Not-Sta gered Max ;Standoff -Tributary Area_-__-_---_-__Trib ------___- 19_sf PV Assembly_ Dead_ Load - psf _ _ -- _ Net end Uplift at Standpff _ --W-PV _ -_ -- Tactual -- -_ _ _-- _ - _3 _ _ J05 lbs Uplift Capadty of Standoff T-allow 446 lbs Standoff Demand/Capaft DCR 43.8% Max Allowable Standoff Spacing ___ Portrait 48" 65" _ Max Allowable; Cantilever _ Porttalt -_ _ _- 19 __-- _ NA,___ Standoff Configuration Portrait Not -Staggered Max Standoff Tributary Area _ -_ Trib 22 sf _ W -PV PV Assembly_Dead Load 3 psf __ _ Net Wind Uplift at_Standoff_- _ _ _T -actual _ Uplift Capacity of Standoff T-allow 446 lbs Standoff Derhangl-capacity I DCR . _ . _ _ 49.0% CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -9223524 00 PREMISE OWNER: DESCRIPTION: HANE, TED HANE RESIDENCE DESIGN: Hanh Nguyen N11414 NQ \,e, SolarCity. MOUNTING SYSTEM: ZEP ZS Tile Wipe BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR MALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS RECIPIENTS 53180 AVENIDA RAMIREZ 6.5 KW PV ARRAY LA QUINTA CA 92253 FAIR ��,. -` � MODULES: EXCEPT IN ON ORGANIZATION, EXCEPT IN CONNECTION WITH IZ , 3055 ClearNer Way San Mateo, CA 94402 THE SAIF AND USE OF THE RESPECTIVE (25) KYOCERA # KU2606XPA PAGE HAMS SHEET: REV. DATE u+vERTER ABB PVI-6000—OUTD—US—Z—A PERMISSION OFITY ISOLARCITY INC. PMENT. WITHOUT THE WRITTEN 760 333-3712 � ) UPLIFT CALCULATIONS PV 4 5/4/2015 (888) (SOL,CITY (65-2489) 638-1028 w:,,.�'piYa«n GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #8 GEC TO (E) UFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 — (1) ABB # PVI-600O=OUTD—US—Z—A LABEL: A — (25) KYOCERA # KU2606XPA CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number: 184SORD-115315 FCI Inverter; Zigbee 6000W, 240V, 96.5% PV Module; 26OW, 232.9W PTC, 40MM, Blk Frame, H4, ZEP, 1000V, w/Ba kbar C-10 . INV 2 Underground Service Entrance Voc: 38.3 Vpmax: 31 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �N� 125A END—FED MAIN SERVICE PANEL N10OA/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! CUTLER—HAMMER Inverter 1 IND 1 t00A/2P Disconnect 3 ABB DC+ Vstart = 120V PVI-6000—OUTD—US—Z—A Dc MP 1: 1x13 (E) LOADS /� L1----------------�----- - EGC --j --------------------------- L2 DC+ 3 11•N 35A/2P ---- GND- ----- -- --------- DC- I --------- ----------- EGC/ --- DC+ 2DC+ v$tart = 120V 13 GEC IDa - GNDEGC--- C- MP 1: 1x12 ————---—--— —— ——— — — — — ————————— — — — ———---— —— ———— —— — ----� tOConduitKit; 3/4* EMT «- N I EGCIGEC— J -- — Z Z --- GEC ---♦ TO 120/240V SINGLEUTILITY PHASE UTILITY SERVICE i CIc O!— A QUINTA �.C But DING &SAFE PPROVE°EPT FOR CONSTRUCTION PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR CODING, MARKING TAPE, DATE TAGGING, OR OTHER APPROVED MEANS. THE, MEANS OF GROUPING SHALL BE WIRE TIES OR SIMILAR MEANS AT LEAST ONCE, AND THEN AT INTERVALS NOT TO EXCEED SIX (6) ' FEET. PHOTOVOLTAIC EQUIPMENT AND SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE Voc* =MAX VOC AT MIN TEMP INSTALLED ONLY BY QUALIFIED PERSONS POT1 Disconnect; 60A.'24 Non -Fusible, NEMA 3R A (1)CUTLER-HAMMER $ DG222URB AC DC — ) Gro%toKiD6- Oeurl t DOA, General Duty (DG) , � 1 AWG 8B, THWN-2, Black O Ise (1) AWG #8, THWN-2, Red - 2 AWG 810, PV Wire, 60OV, Black Voc* = 560.64VDC Isc = 9.09 ADC O (i) AWG 810, Solid Bare Copper EGC Vmp = 403 VDC Imp= 8.39 ADC (1)AWG 810, THWN-2, White .. • ..-(1.)AWG•#8, THWN-2, .Green, . •EGC/GEC NEUTRAL Vmp=240 VAC Imp=28 AAC -.(1)Condult Kit; 3/4'• EMT • • • . • . • .. 1)Conduit Kit •3/4' EMT. (2)AWG 810, O PV Wire, 600V, Black Voc* =517.51 VDC Isc (1)AWG Solid Vmp = 372 VDC Imp= 810, Bare Copper EGC 8.39 ADC (1.)Conduit Kit 3/4' EMT CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER J B-9223524 00 PREMISE OWNER: DESCRIPTION: HANE, TED HANE RESIDENCE 53180 AVENIDA RAMIREZ ' DESIGN: Hanh Nguyen .010.,SolarCity MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ZEP ZS Tile WTile 6.5 KIN PV ARRAY LA QUINTA, CA 92253 ��� NODDLES IN CONNECTION NTH A Way 3055 Mateo. Son Moleo, CA 94402 ORGANIZATION, EXCEPT THE SALE AND USE OF. THE RESPECTIVE (25) KYOCERA # KU2606XPA PAGE NAME SHEET: REV DATE INVERTER. ABB PVI-6000—OUTD—US—Z—A SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLM07Y INC.' 760 333-3712 ) THREE LINE DIAGRAM PV 5 6/4/2015 (Beg) (SOL)CITY ((765-2 638-1028 48g)50�63� t0iy� ELECTRICAL CALCULATIONS -- 4 {/1eJ r 41 { — 'r'�4 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE. EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER JB -9223524 00 MOUNTING SYSTEM: ZEP ZS Tile WTile MODULES: (25) KYOCERA # KU2606XPA INVERTER: ABB # PVI-6000—OUTD—US—Z—A String and 2 Combined Strings 35 OCP Size = 35 Module Type: Module Count: (cont = (Amps): (cont * 1.25 = (Amps) Kyocera 260 1000V 25 30 deg C ampacity = 11.36 (cont = (Amps) Branch Circuit Individual MPFr Start ampacity 55 1 strings per Branch A 1 strings per Branch B 13 modules per series string 12 modules per series string (cont * 1.25 = (Amps) String Branch A Branch B Conductor: Conductor: Conductor: (cont * 1.25 = (Amps) 14.2 14.2 14.2 30 deg C ampacity = 40 40 40 PV Wire Size: AWG #10 AWG #10 AWG #10 (cont = (Amps) 11.36 11.36 11.36 Start ampacity 40 40 40 Temperature derate (%=F) 0.41 0.41 0.41 Conduit fill derate (%=#) 1 0.8 0.8 Derated ampacity 16.4 13.12 13.12 ont * 1.25 = (Amps) Nlcmpacity 14.2 14.2 14.2 40 40 40 Inverter Output Inverter Type: Inverter Count: Total ABB PVI -6000-S AFCI 1 (cont = (Amps): 28 (cont * 1.25 = (Amps) 35 OCP Size = 35 Conductor 3: AWG #8 THWN-2 (cont * 1.25 = (Amps) 35 30 deg C ampacity = 55 (cont = (Amps) 28 Start ampacity 55 Temperature derate (%=F) 0.91 Conduit fill derate (%_#) 1 Derated ampacity 50.05 (cont * 1.25 = (Amps) 35 Amoacitv 50 REMISE OWNER: DESCRIPTION: HANE, TED HANE RESIDENCE 53180 AVENIDA RAMIREZ 6.5 KW PV ARRAY LA QUINTA, CA 92253 (760) 333-3712 PAGE NNE.- ELECTRICAL AMEELECTRICAL CALCULATIONS Hanh-Nguyen SHEET: REV: DATE: PV 6 6/4/2015 No .0145olarGt . 3055 Cleaview Woy San Moteo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcity.com r ELECTRICAL ONE LINE DIAGRAM EXISTING ELECTRICAL SERVICE ENTRANCE AND LOAD CENTER ` 125A 240V 10 100A MAIN BREAKER , 100A 2P Qo PHOTOVOLTAIC SYSTEM UTILITY I 13 ARRAYMODUL#1 DISCONNECT SWITCH CUTLER HAMMER # DG222URB KYOCERA (E) METER# 164SO0D-115315 - 60A, 240VAC - ' - - - #KU2606XPA PROPOSED BI-DIRECTIONAL METER# I I TO 120/240V SINGLE PHASE UTILITY SERVICE 3380 WATT (DC) 35A AC PV ARRAY #1 -- - - - - - - - - - - - - - - - - - - - - - - -- 12 MODULES -- ----- --------------------------------------------- KYOCERA DC. #KU2606XPA . tt 3120 WATT (DC) 6500 WATT UTILITY INTERACTIVE INVERTER " 120 TO 600 VDC TO 120 /240 VAC 10 - - - - - - ABB # PV1-6000-OUTD-S-US-Z-A J J 2 ( i ) AWG #8, THWN-2, Black • (4) AWG #10, PV WIRE, Black (1 ) AWG #8 THWN-2, Red (2) AN #10, Solid Bare Copper (1 ) AWG #10, THWN-2, White (1 ) AWG #8, THWN72, Green, EGC —(1)Conduit Kit; 3/4" EMT r . -, Vmp = 240 VAC • Imp = 28 AAC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER: JB -9223524 0 PREMISE OMNER: HANE, TED DESCPoPRON: HANE RESIDENCE DESIGN: Hanh Nguyen Solarcity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., IN WHOLE OR IN MOUNTING SYSTEM: [MODULES: 53180 AVENIDA RAMIREZ 6.5 KW' PV ARRAY -'.:�ge -�. ��� o NOR SHALL IT BE DISCLOSED ZEP ZS Tile WTile _ PART TO OTHERS OUTSIDE THE RECIPIENT'S LA QUINTA, CA 92253 } ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (25) KYOCERA # KU2606XPA PACE NAME 3055 arview Way Son Cle CA 94402 SHEET: REV DATE THE WRITTEN PERMISSIONSOLARCITY EOFISOLARgTY INC. INVERTER: ABB PVI-6000-OUTD-US-Z-A ABB 760 333-3712 ) - ONE LINE DIAGRAM PV 7 6/4/2015 T:(650) 638-1028 F:(650) 638-1029 (888) -SOL -CITY (765-2489) www.solarcitycwn CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 53180 Avenida Ramirez AC DISCONNECT INVERTER AND DC DISCONNECT UTILITY SERVICE r--------------------------� SOLAR- PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK -FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE = 240V JB -9223524-00 CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARgTY INC. JOB NUMBER: JB -9223524 00 rn wx uwntw: unmruuw: HANE, TED HANE RESIDENCE 53180 AVENIDA RAMIREZ 6.5 KW PV ARRAY LA QUINTA CA 92253 r PAGE NAME 760 333-3712 ( ) SITE PLAN PLACARD utNUN: Hanh Nguyen =_��° SolarCity •• �„ 1.4 MOUNTING SYSTEM: ZEP ZS Tile Wye --° j MODULES (25) KYOCERA # KU2606XPA cross gearview Way Sm Mateo, CA 94402 (866) (650) 638-102829 (765-2489)�www.solarcity.com SHEER: REV: DATE PV 8 6/4/2015 I ABB PVI-6000—OUTD—US—Z—A WARNING: PHOTOVOLTAIC POWER PHOTOVOLTAIC DISCONNECT Label Location:. (C)(IC)(CB) ry= Per Code: CRC R331.2 11 Label Location: (DC) (INV) Per Code: • ' - CEC 690.14.C,2' 'Label; Location: (DC) (INV) Per Code: CEC 690.53 ' Label Location: v (DC) (CB) Per Code: CEC 690.17 Label Location: Label Location (AC)WARNING (DC)(INV)(CB) •- j Per Code:THE DC ELECTRIC SHOCK HAZARD CEC 690.35(F) �aPHOTOVOLTAICCONDUCTORS • 'TO BE USED WHEN < s - -• . . . INVERTER ISMAY BE ENERGIZED r UNGROUNDED. Label Location: - (DC) Per Code: CEC 690.17 Label Location: ' •'�. _ - - - (POI) r Per Code: CEC 705.12.D.7 Label Location: ' • i } . I G &�� BUILDING SAFE UIQ q (POI) TY DEPT. Per Code: �N CEC 690.54; CEC 690.17? FOR CO��® UCTION DATS 13Y '- , ; + 3' ' - . �� � � 1, , �: ', • ` • Label Location. (D) (POI) .. 'r. + Rri v"•`" ''' - - ••� ( _. ' -•� 7: ' " Per CoYSTEM de: z �` (AC): AC Disconnect 4 CEC 690.64.6.4 �' a . �,' o. (C): Conduit j • f . . < :- • (CB): Combiner Box (D): Distribution. Panel (DC): DC Disconnect,.: iLabel Location.' ' (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (POI) " - '- • (LC): Load Center `• k Per Code:CE IS r,° • "' c (M): Utility Meter' ' CEC 705.12.D.7; - t. } ' ': (POI): Point of �YSTEMInterconnection _ , .3055 Clearview Way r. ;, . „r - �•' San Mateo, CA 99402 T:(650) 638-1028 F:(650) 638-1029 01� (888}SOL-CITY (765-2489)wwwsolarcity.com w - ,. .. �� - • �7 .f - it - 5 .:I� O - Label Location: WARNING (INV) Per Code: SHOCKELECTRIC HAZARDIF AGROUND FAULT IS INDICATED CEC 690.5(C) NORMALLY-• . . CONDUCTORS MAY BE UNGROUNDED . ENERGIZED t' Label Location: ,A. PHOTOVOLTAIC AC (AC) (POI) DISCONNECT Per Code: 1 CEC 690.14.C.2 Label Location: MAXIMUM AC A(AC) (POI) . _ OPERATING CURRENT Per Code-'. s• OPERATING VOLTAGE CEC 690.54 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED MALL NOT BE US]�' THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISC IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATIOLabelSet EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE`.SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY ' 13 "SolarCity Z pSolar .Zep System for the roofs using replacement tiles Next -Level PV Mounting Technology zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the`suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheel Rev 02.pdf Page: 1 of 2 4 "11"SolarCity ZepSolar Components I /I Replacement S -Tile Part No. 850-1435 Listed to UL 2703 Next -Level PV Mounting Technology Replacement W -Tile Part No. 850-1437 Listed to UL 2703 Replacement Flat Tile Part No. 850-1436 Listed to UL 2703 Tile Roof Attachment Kit Interlock Leveling Foot Part No. 850-1434 Part No. 850-1388 Part No. 850-1397 Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 % $I]= A Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheel Rev 02.pdf Page: 2 of 2 Description W 0`1 PV mounting solution for concrete tile roofs CpMP111 Works with all Zep Compatible Modules • Zep System UL 1703 Class A Fire Rating for Type 1 and Type 2 modules U� LISTED Auto bonding UL -listed hardware creates structual and electrical bond Specifications QP Designed for pitched roofs Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards • Zep System grounding products are UL listed to UL 2703 and ETL listed to UL 467 • Zep System bonding products are UL listed to UL 2703 • Engineered for spans up to 72" and cantilevers up to 24" ' Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain zepsolar.com This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the`suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheel Rev 02.pdf Page: 1 of 2 4 "11"SolarCity ZepSolar Components I /I Replacement S -Tile Part No. 850-1435 Listed to UL 2703 Next -Level PV Mounting Technology Replacement W -Tile Part No. 850-1437 Listed to UL 2703 Replacement Flat Tile Part No. 850-1436 Listed to UL 2703 Tile Roof Attachment Kit Interlock Leveling Foot Part No. 850-1434 Part No. 850-1388 Part No. 850-1397 Listed to UL 2582 Listed to UL 2703 Listed to UL 2703 % $I]= A Ground Zep Array Skirt, Grip, End Caps DC Wire Clip Part No. 850-1172 Part Nos. 500-0113, Part No. 850-1448 Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 ETL listed to UL 467 850-1467 zepsolar.com Listed to UL 2703 This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. 12 31 14 ZS for Replacement Tile Applications Cutsheel Rev 02.pdf Page: 2 of 2 • - .J - -' .' - Y ri. r. • r • - . � � r _ - 'j , -' y ,• • + L t � • • f • i ` tt . , J _ ' :' 'I • u _ w _ ' a 4 Additional highlights:Solar inverters -. RS -485 communication interface J (for connection to laptop o, data ;-ABB string invertersf logger). ,, 6,,, •UTD 5000/6000 - - Integrated'Arc Fault Detection and' Interruption (-A Version). L a ' - i. it w ,.. .. •M —.. •...0 +a '•."� r �♦. - � -f _ (�si �' _— - v t •i r � � o ~ � ' 1. t 4 r'• � a Technical data and types ' Type code PVI-5000-OUTD-US PVI-6000-OUTD-US IInput side _ + %+ Nominal out ut ower P....... P........ 5000w 6000W ' _ ' , {? , _ ........ ......... Maximum output power ........................................:......... .............. .................... ....... ......... ................. SOOOVJ .. 6000W .............................................. ` r _ Rated grid AC voltage - 208V 240V 277V 208V 240V _ , t IInput side (DC) - --- -- -- - - - + t - . - = ; • ,... 2 r _ '• Number of independent MPPT channels • .......... ........ .. ... ....... 2 ....... ... .... ..................... ...... + A .w - ?.. • Maximum usable power for each channel.....:. ........ .4...... "....................... : 4000W................................................................................. + .......... .. •' . f Absolute maximum voltage(Vmax)......................................................... ................................................................. 600V ................. .................... • y i Start u volt. a start P ..............9... )...... .. .... + 200V ad 120 350 - ............................_C..1:................1..............................'............................................. " �. . ' • - - Full power MPPT voltage range .................. ....... ..... ... 200 - 530V ...... t •• ................ vol[. e rah. e .......... P........................................9............@...................._.............. i.. ........................................- .. , _ .......... .................. .......... ......... .. 0.7 x Vstarf - 580V' : .................................................... - `- Maximum current Idcmax) for both MPPTin arallel...'..36A .... ; .....................(..........................................................P............,......... MMimum usable.current per channel ..................:...............::.................................................................................................................................................................... 22A • "2 . ............................... .............:...... Number of wire landin terminals er channel r 9 2 Pairs ......................................................... ' ""'�' ` ' "+ . r • ....... . ••••••••••� - Array wiring termination - .. ............................................. - Terminabloc, ressure clamp, AWG16-AWG6 , - - � -'[Output side (AC) - - Grid connection t e Y..P 1fJ/2W Slit t -0/3W i 1O/2W 1O/2W Slit O13W 10/2W - P.... P................- .. .. - r' ..................................... ......... Ad'ustablevolta eran a min-Vmax) 183V -228V 221V -264V 244V-304V...€....t83V-228V 211V -264V i 244V -304V ° S Grid frequency ......................... :.......................... 60Hz ....... .... ............................................................................ - ( a Ad ustable rid fre uenc ran e r 1..................9..............9...........Y.p........_9............:°............................................... 57-60.SHz ............ ... ........ ........ ........ ............. ..............24 + Maximum current Imo. u .... s ..............1...,.: - .............................................(...........).' •aM.......................................... �.. 27 s.........i........23... s 20 s 30 5 28 5 [:::...... Finn ' 1ua..::......i................'..].,M ......._.�.y..........i...............'4w�e..........E...............:..7.u............ s Designed for residential and small The wide input voltage range p g, g_ Highlights: ' : _ J Power factor ............_......................r.::......................................................................... Total harmonic distortion s > 0.995 ........................................ ...... .......... .. , <2% 1 Z. ' - - commercial PV installations, this makes the inverter suitable to low _ Single phase and split phase output at rated ower P............................................................................................................................................................................................. „ Contributory fault current' -36.25 A°k/ ,; 36.5 A/ 31.75 A/ 36.25 A°w� ,i 36.5 Apk� i 31.75 A! o• _ inverter fills a specific niche In the with reduced p ower Installations W ed r grid connection. a 25,63AaMs.....i.....25.81.A..........._2245AAMs.....i...._25.63i�M�F.....i...._2581,Pams........._22:45AHMs...... ¢ Grid wiring termination type ` - Terminal block, pressure clamp, AM4,AWG4 ,. ABB product line to cater for those strip size. g - Wide input range for increased t pnput r a installationsproducing between The transformerless operation offers - ', flexibility. stringingP.. Reverse olanly_.rotection . ...... P........................................................................:................................................................... Yes ............ ....................................... ...................... 5kW and 2OkW. f t high performance efficiencies o up o _ pT n r is MP The high speed a d p ec a Over -volt. a rotection type 9.....P ....................... *, Varistor, 2 for each channel - ' , 97.1%. ' pV array ground fault deteclioh - - Pre start-up Rso and Dynamic GFDI (requires iloaling arrays) - - algorithm offers real time power [output r i• This inverter includes dual input P- Free remote monitoring capability im r v energy tracking and p o ed e e gY Anti-islandin rotection 9..P.............,.9rt...............................................................................,................................,.................................9.............................:..................... Meets UL 1741/IEEE1547 re wrements ' : Meets UL 1741/IEEE7547 re urements 9............................ _ section to process two strings.with This available with every installation.s Over -volt. a rotection t e 9.....P..........................YP..............................:...........................::...::......................................,...............................,........................................... Varistor, 2 Lz / L, - G) Varistor, 2 , - Lz / L, - G 5�................,........1.......................... ' independent MPPT.' enables homeowners to view their _ ` Maximum AC OCPD Ratin i Outdoor~NEMA 4X rated enclosuTe� '{* , _ `,w -; ^_ - Efficiency 35A 30A 25A 40A 35A 30A _ - — - - - + .,' t� y r.• �. t` _ •` .T _ The high s eed and reclse MPPT - , > energy production and offers Installers , i 'for unrestricted use under an ,. y a Maximum efficiency _ 97 1% ` g p p . . - �.- algorithm offers real-time power g way of a proactive.' r tiv and economic PY - environmental conditions. f ''-, .......................................................................... • CEC effcienc .................................Y............................................................................................,.............................. ................:......................................................................................................................... ........................ .. ....... 96% 96.5% 96.5%...-....€„--..._9690.-,.- 96.5% 96.5% .. ............................... tracking and energy harvesting. maintaining and troubleshooting the g g . _ Integrated DC disconnect switch User interface lOperating performance Graphic display Graphic display , ' Flat efficiency curves ensure high ,- system. in coin liance with international P • Y : Stand -b consum lion Y.....................P......,................................................................................ <SW <8w s . efficiency at all output levels ensuring Standards (S Version). N sumption <0 6W <0 6W consistent and stable performance -' - ommun catio _ User -interface 16 characters 2 lines eco display •' - - across the entire input voltage and - ..Remote monitonn.....1xRS485 incl.j................. ................... 9,5............................................................................... .er F. ...... ....... .. VS.J700 Dala Lo er o t ............ .......... - ..........9......1...e.1............................................................................, ' �^ • output power range. - - ' ,+ Wired local rn ntonng (IxRS485 incl.) PVI USB RS485_232 (opt.) _ - P - - , This outdoor inverter has been r .. - � - - - _ . -- IEnvlronmenlal -- Ir operating temperature range Ambient a ope a g p g .,. - it 13 to +140 -25°C to +60°C) with +14 F to +60 C 13°F to 0 (25 C ) , . _ designed as a completely sealed unit to ? ' .........................:.......................................................................... ••. ..... ........ derating_above 1.22..F..(54.91...............::... F , -' withstand the harshest environmental - • !, ...' * .Ambient airs..... .temperature, range 40°F to +176°F (-40°C.to +60'C).. ... 40 F to +176 (40 C to +80°C) ” ...........................Relative humid il.Y............ ... ...................... ............. ... ...r...0.:...009'o RH conderising......................................... 0-10090 RH condensing......................... .' c x conditions. Lr �. _ .- _ „ ,N ,� .. . `" + Acoustic noise.emission level Maximum o eraUn alUlulde without derating .... (A) ®1 m . .... ........................... .............................. .... .. < 50 db (A) ®1 m < 50 it ., 6560 ft (2000 m) 6560 ft . m) a 1............................".............:........ f R; . F Power, and produi lvlty ; •f ,............................P.....................................................................................................................:............:.......................................................................... 2. Inverter can apply That much current -Breaker will open . _ 1' . • for a better world'" - _ - �, - - 2 ABB Solar Inverters I Product Flyer for PVI-5000/6000-TL-OUTD-.yt • 4 ' •y , _ .. +o CUTTING EDGE TECHNOLOGY As a pioneer with four decades of experience in the development of photovoltaic systems, Kyocera drives the market as a leading provider of PV products. We demonstrate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best -in -class solar energy equipment. QUALITY BUILT IN • UV -stabilized, anodized aluminum frame in black • Supported by major mounting structure manufacturers • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire works with transformerless inverters • Amphenol H4-UTX locking plug-in connectors provide safe, quick connections PROVEN RELIABILITY • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed by TUV Rheinland • Only module manufacturer to achieve the rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • LIL1703 Certified and Registered, UL Module Fire Performance: Type 2, CEC • NEC 2008 Compliant, IEC 6121561730, and ISO 14001 Vpt4Pq T/9 FAQ/ `0 C UL US - OMPA KU -60 1000V Z Series KU255-6XPA KU260-6XPA HIGH EFFICIENCY MULTIGRYSTAL PHOTOVOLTAIC MODULE SOLAR by KYOCERA KU -60 1000V Series ELECTRICAL SPECIFICATIONS MODULE CHARACTERISTICS • , • • • • Cells per module: 60 (6 x 10) •�� •" ' Dimensions: 65.43ini38.98ini1.57in • length/width/height (1662mm/990mm/40mm) l255 260 W Weight: 47.4lbs (21.5kg) P J Vmp 30.8 31.0 v PACKAGING SPECIFICATIONS le,p 8.28 8.39 V A Modules per pallet 20 V. 38.0 38.3 V Pallets per 53' container. 36 C�pj Pallet box dimensions: 66ini40ini43in 1. T 8.83 T 9.09 1 length/width/height (1 675mm/ 1005mm/ 1 055mm) Ptd -n. +5/-0 +5/-0 % Pallet box weight: 1060lbs(480kg) :,� ,. .- •- 1.57 - !mW 4.3] 45 LT -n-__45 oC TNSI t J , 4 POTTED P 1 83 1 87 W JUNCTION Vmp 27.7 27.9 _ V ] - ; s ❑ -_-_a CABLE W/ y (_� (+� Imp 6.61 6.71 A PAL CONNECTOR STABILIZER BAR V� 34.8 35.1 -� - " V-1 I 7.15 7.36 A PTC 228.3 232.9 -� Ili I w' Wr•Am,y-'la „'efts STABILIZER BAR CPm: -0.45 -0.45 %/°C IID (z�w Vmn - -0.48- - 0.48 - %/°C ' Imp 0.02 0.02 %/°C (V. -0.36 -0.36 %/°C 38.98"(990mJ Ltt 0.06 0.06 m 0 (D/ Operating Temp -40 to +90 -40 to +90 °C Grounding holo slotted Buurtl°a Hole 0.16'(4.0 0.35-x0.47- (9-lZecO D • FRAME CROSS SECTION DIAGRAM lSeries Fuse Rating 15A 1 >441' Maximum DC System Voltage (UL) 1000 V � � o Hailstone Impact in (25mm) @ 51 mp (23m/s)1 I.M-o 1.65-(4m0 'Subject to simulator measurement uncertainty of +l- 3%. KYOCERA reserves the right to modify these specifications without notice. LONG/SHORT SIDE STABILIZER BAR NEC 2008 COMPLIANT WARNING: Read the instruction UL 1703 LISTED /� manualinitsentiretypriorto handling. installing & operat- 062614 Ing Kyocera Solar modules. �, OUR VALUED PARTNER _ 1 8 7 6 5 d 3 2 1 O D 9.11 (2311 l.W (tezl , e.ee (220] 1 .33 (e] mF OFF • Oi - N - O • CCNCEHI HNOLImUIa FOR - TANGDN KNOCKOUTS FOR ® ® ® 1/z, J {, 1. 1-1/{ CONOUR- 30 g1f�1Y 31/{ COHOUO _ o r np feel aw - AS (22] — �uNhNc Nous 6 r {.21 poi] 7.00 DTaI - 6 1 TANGEHML KNOCKOUTS FOR r -1/2 CONOUO HOTS: OUaNRT1' 1 1. METRIC OIMENSIONS W MIWMETERS] ME SH MN W HEIS. • Z PRE RANGE Of lA1GS 6 1/0-/14 COPPER OR M MW _ - GUANmv 1 zez [eT] a. A .. 6.40 (2131 - A CUTLER-HA11E�R �cTMN HEETNFAK W7Y1 ffil ZepSolar ZS Comp'" I Grounding and Bonding This document describes the mechanics of how the electrical bonding is accomplished between the UL Listed hardware components used in Zep Solar's ZS Comp mounting solution for composition shingle roofs. Zep Compatible`" systems do not require running copper conductors to each module. The act of physically installing each component simultaneously establishes an electrical bond, as described in the following pages. Document 800-1478-001 Rev A www.zepseLar.com PAGE: 1 of 5 © 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnageswithout any prior notice. ALL rights reserved. Date Last Exported: June 25.20134:45 PM ®. ZepSolar Interlock Interlock Zep r�rl' r ste to Tongue side Key Side Bonding Tongue Side Bonding Tongue side in closed position ZS COMP I GROUNDING AND BONDING Side view Interlock Module Bonding locations on Key side Forced interference during rotation If Interlock Zep causes teeth to cut through anodization on module frame, resulting in robust and UL certified bonding path Cutting "teeth' Bonding location on Tongue side Forced interference between mating parts from module rock -in motion cuts into module frame, removing anodization and resulting in robust and UL certified bonding path Document 800-1478-001 Rev A www.zepsolarcom m 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. ALL rights reserved. Date Last Exported: June 25.20134:45 PM PAGE: 2 of 5 r -ZS COMP I GROUNDING AND BONDING ZS COMP I GROUNDING AND BONDING ZepSotar :. Ze Sola Interlock, continued 5� .1. w Leveling Foot , _ t ' :f _ - a L - ..y t•- - - • ' - Tongue side — Key side * .. a - - i ., ^« • s ll - - - r t . - ' , Spring clip C / 2• PartNo.850-1388 ... .. _ - - - _ F' •} • '•. r.:. }a, - - >r.' �.' .ra • i _ i ' u tY... R L , UL Listed to UL 2703 � - - • - .- � , i '� , s �o i -'E. • 4. ' - .+. -' ` . . J � , + • - •- Ih �� it RJ f4Aw`� ! ,7 « i c •.�4�WkNR nwn .. ._ a t .� ,. m. nvniwu„m f _ I Bonding Path Key and Tongue. • _ Part No. 850-1392 y y'-�.;'••;3. ,The Leveling Foot top portion (the Rockiq has a stainless steel - J UL Listed to UL 2703 - + spring clip that bonds to the adjacent module frame on both t ”. - The Interlock bonds modules on all 4 sides to create a hyper- t • - .y=' • _ 4 - ,'r s - Key and Tongue sides.. , -'.• _ bonded array where every module is structurally and +' f - - • -` electrically bonded to the surrounding modules. - -� = s , „ - • t' •r, - +. - : Levelin Foot - Bonding With Module Frame s.: ?` - .4 + ` Module - - �• ri f 'y r, gy • r ' - { *! s I r , Y Down -root r 2 3 d Y Tongue side O Y � s r = � l�+e,•:... nt }Key side - ' - - . Interlock ik • - -' ` • • ' �.• - Ke side inserts into Zep Groove (rock - o Module in nextrow drops on the Tongue side Key P I 1 - ' P 9 , , , - ' _ t Bonding Path -Array , - ' v _ r Bonding Path North and South Modules w, r✓ w %y w ar .— �J� /" t• �' W Al W M W Po o Interlock - z - + _ - .— �J� /" t• �' -� Bonding location on - - A• Down -roof a Key side ` Bonding path - • •'f ©�-Q •f'✓�/1 ... .. . - Leveling Foot i .. •. Q ,• ,f,; ?;: h .. , V +' resulting in robust and UL certified bonding path S -� _❑-« Bonding path "JI Document 800-1478-001Rev A , www.zepsolar.com `. ' - - i(y • Document B00-1478-001Rev A_.' • www.zepsolar,com - PAGE: 405 - - • .,� PAGE: PAGE: 30f5• Zep Solar, Zep Solar reserves the right to make specifications chnages without any prior notice. All rightsreserved. .. .. - 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved.. _ , t. 4•Date Last Exported: June25,20134'45PM.. t - �' e , .... - - • - ' d4'I '.L ', .. ., � .-+. •� , �'QYQ, r� � •I - ,, •. . . t . ♦ t - G L � 1J)J ., icer •f -�' >• : Bonding on 'Module rotation Burin drop-in creates forced KR ,,, ,,,- • • .— �J� /" t• - Down -roof , , r = ' Down -roof r�.• i• ,. �' `` • - Tongue side !+ interference between Zep Groove and spring clip, •-a`. I:. .. , t� %- " - b cutting into module frame, removing anodization and - ,. • - < • , +' resulting in robust and UL certified bonding path Document 800-1478-001Rev A , www.zepsolar.com `. ' - - i(y • Document B00-1478-001Rev A_.' • www.zepsolar,com - PAGE: 405 - - • .,� PAGE: PAGE: 30f5• Zep Solar, Zep Solar reserves the right to make specifications chnages without any prior notice. All rightsreserved. .. .. - 02013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved.. _ , t. 4•Date Last Exported: June25,20134'45PM.. t - �' Date Last Exported: June 25, 20134:45 PM + w ;fi ' - - • - ' r � t i ZepSolar ZS COMP I GROUNDING AND BONDING Ground Zep Setscrew Part No. 850-1172 UL Listed to UL 467 and UL 2703 Ground Zep Installation O rol tl Key side Ground wire channel The Ground Zep provides as Ingle point of connection for theEquipment Grounding Conductor (EGC) from the array to a building ground. Insert Ground Zep into Zep Groove of module frame, Use the Fiat Too to rotate the Ground Zep 90 degrees, so that set screw Insert copper EGC into ground wire on array perimeter is pointing straight up. channel. Tighten set screw using torque values shown in the ZS Comp Installa- tion Manual. Bonding Path - Array to Ground #, Ground Zep Equipment Ground Conductor Bonding path IDown -roof Document 800-1478-001 Rev A www.zepsolar.com PAGE: 5 Of 5 © 2013/EN Zep Solar, Inc. Zep Solar reserves the right to make specifications chnages without any prior notice. All rights reserved. Date Last Exported: June 25,20134:45 PM