Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10124 (SFD)
44.. 01. C&t�v P.O. Box 1504 No. 101.24 Building 78-105 54-640 Ramirez LAQUINTACCALFORNIA92253 Address �-- Owner Mailing "MarvinJordan/Joan Bromberg BUILDING: TYPE CONST. OCC: GRP. Address P. ©. Box 228 A.P. Number. City Zip Tel. La Quirnta 92253 564-6011 Legal Description Lit 17 Block3f}6 Contractor Project Description SPD M L Construction Address P...O. Box 228 City Zip A Tel.: LaQuinta 921253 564-444.7 State Lic. City & Classif. B 343335 Lic. # Sq. Ft. 11334 No. No. Dw. Size Stories Units Arch., Engr., Designer New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ Address Tel. Permit does not include vialls or pool City Zip State Lic. # LICENSED CONTRACTOR'S DECLARATION I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section Y Qpkof Division 3 of the Business and Professions Code, and my license is in full force and SIGNATURE / - DATE, f OWNER -BUILDER DECLARATION Estimated Valuation I hereby affirm that I am exempt from the Contractor's License Law for the following 104,615.10 reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, 'alter, Improve, demolish, or repair any structure, prior to its Issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to PERMIT AMOUNT the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of ' Division 3 of the Business and Professions Code, or that. he Is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit Plan Chk. Dep. 250.00 subjects the applicant to a civil penalty of not more than five hundred dollars.($500). , Plan Chk. BBI. 304.41 ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Const. ` _ 657 . 04 .� Professions Code: The Contractor's License Lew does not apply to an owner of property who F1 builds or Improves thereon and who does such work himself or through his -own employees, ' Mech. 55 0 50 provided that such Improvements are not intended or offered for sale. If, however, the building K 11 y 11 or improvement is sold within one year of completion, the owner -builder will have the burden Electrical 1136. of proving that he did not build or improve for the purpose of sale.) - ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to con- Plumbing 147 . 00 struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law A does not apply to an owner of property -who builds or improves thereon, and who contracts for S.M.I. - - 10 . 50 such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) Grading 20 . 00 ❑ I am exempt under Sec. B. 8 P.C. for this reason • Driveway Enc. 20.00 Date owner Infrastructure 2298.49 Arts in Publl , 25.00 WORKERS' COMPENSATION DECLARATION "s I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) nAr. nr < n hin6 A ' f!._5 E —04 14 Policy No.—C'mpany ,JCopy is filed with the city. ❑ Certified copy is hereby furnished. TOTAL 3924.01 3674.01 CERTIFICATE OF EXEMPTION FROM REMARKS WORKERS' COMPENSATION INSURANCE (This section need not be completed 1f the permit Is for one hundred dollars ($100) valuation or less.) I certify that in the performance of the work for which this permit is issued, I shall not ' employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this .Certificate of Exemption you should become ZONE: BY: subject to the Workers' Compensation provisions of the Labor Code, you must forthwith Minimum Setback Distances: comply with such provisions or this permit shall be deemed revoked. Front Setback from Center Line Rear Setback from Rear Prop. Line CONSTRUCTION LENDING AGENCY Side Street Setback from Center Line I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Side Setback from Property Line Lender's Name Lender's Address FINAL DATE INSPECTOR This is a building permit when properly filled out, signed and validated, and is subject to expiration it work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. Issued by: Date Permit I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives -of this city to enter the above-. mentioned property for inspection purposes. Validated by: Signature of applicant Date Mailing Address Validation: City, State, Zip CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBING FEES IST FL. SO. FT. ® $ UNITS COLL. AREA 2ND FL. SO. FT. YARD SPKLR SYSTEM POR. SO. FT. ® MOBILEHOME SVC. BAR SINK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS CAR P. SO. FT. DUCT WORK DRAINAGE PIPING WALL SO. FT. DRINKING FOUNTAIN. SO FT ® HEATING (FINAL) URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASH ER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED GRADING yd. $ plus x$ LAUNDRY TRAY AIR HANDLING UNIT CFM FINAL INSP. lupcu. KITCHEN SINK ABSORPTION SYSTEM B.T.U. SVC WATER CLOSET' COMPRESSOR HP ffAMPERESSERV LAVATORY HEATING SYSTEM FORCED GRAVITY T SHOWER BOILER. B.T.U. SO. FT. ® c BATH TUB SO. FT. @ c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1% c SEWAGE DISPOSAL ' SO.FT.GAR ® VAc HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PLCK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK 7 ( GROUND PLUMBINGJJS� UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE ! ,� ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR'SlPFl9�R1QI(l OUGH WIRING. DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE m/�/f/ GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING yd. $ plus x$ _$ LUMBER GR. FINAL INSP. lupcu. FRAMING [2zh Q/ FINAL INSP. ROOFING IOIIIYlql REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL THING 111910A G MESH INSULATIONISOUND 110A FINISH GRADING FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURESRNITIALS GARDEN WALL FINAL DESERT SANDS UNIFIED'SCHOOL DISTRICT '82-879i.Highi ay 111" NOTICE: Indio, CA 92201 Document Cannot Be Duplicated (619) 347 8631 Date 10/8/91 Type of Permit JLa Quinta No. 110918 Permit # 110124 Log # Owner Name Marvi&, Jordan/Joan Bromberg No. 54=640 street Ramirez city La Quinta zip 92253 Study Area 110 APN # Tract # Lot # 17 Square Footage 1834 Type of Development Single Family'116No. of units Comments At the present time, the Desert TSands Unified School_ District does not collect fees on garages/carports,. covered patios/walkways, residential additions ;under 500 square feet, detached accessory structures or replacement-mobilel omes.. I Alias been determined the above-named owner is exempt from paying school fees at 'thistime due to the following reason: EXEMPTION; NOT APPLICABLE, This certifies that schoolticility fees imposed pursuant to. Government Code 53080 in the amount of' 1.58 X 1834 or $ 2;897.72 have been paid to D.S.U.S.D. for the property'listed above and flint building permits and/or; Certificates of Occupancy for this square footage in this proposed project may-now,be'issued. Fees Paid By M. L. Construction Telephone 5641447 Name on :the check, - By James E. Lively Assistant Superintendent, Business Services Fee collected /exemp o d by Kathleen Emmerlin` r' Payment Received Signature 'Check 416. 1022 Collector: Attach a copy o county or city. plan check application4orm to district copy for all waivers. Embossed Oiiginal- Building.Dept./Applicant Copy - App lican ' ceipt Copy- Accounting COMMUNWEALTH LAND TITLE CO. NO'. GOP TIED ORDER #t 168309 ESCROW # 5113 -JC } a !t WHEM RECORDED lIBIL TO:31 Marvin L. Jordan— Joan 60' Joan K. Bromberg P.O. Box 30163. Laughlin, Nevada 89028 'IY" SPACE.ABOTHIS_LINE-FOR CORDER'S USE • llalL THY ST8T8l�i'1'S TO. Marvin L.`Aordan ; Joan K. Bromberg P.O. Box 30163. -�=-• - Laug4lin;=--Nevada--89028-• ------ = G. R A. N 'T D X-9 ,D . e undersigned 'grantor (s),:;d : Documentary transfer taxi $28.60 (X) computed on full value roperty conveyed, or ( ) computed,on:full value less. value .of liens an encumbrances remaining at time of sale ( ) Unincorporated area: (x) city.of'. FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged:, John Hancock and Loui.ee A. Hancock,, husband and, wife as ,joint tenasats hereby GRANT(S) TO y Narvin L. Jordan and Joan K. Bromberg, pq.joint.tenants.. _.._that property in Riverside .count_y.,_S.tate�Of-California,-dseo ihed�as� —. Lot 17 in Block 306.of Santa Carmelites at Vale .,La . Quinta Unit Up., 28, as per Map recorded in Book 19 pages 59 and 60 of = !laps, "in the :office of the .County Recorder of Riverside County, California. Dates May 31, 1991 STATE OF BNZ.4 ). COUNT2 ) v before..me,.On _the undersigned, dNotary Public ajad •fol_ said S a e, pars na y app tired• p personally -known to me =(or proved to me on the basi of satisfactory evidence) to be. the •person whose names =ow- subscribed' to twithin instrument and "acknowledged that LL- execut ie e. Wimy14 hands and :offis. ea . Signature: ... OFFICIAL SEAL ELISA M. AMEND NOTARY PUBLIC CALIFORNIA LOS.ANGELES COUNTY MY. COMM': EXP. APR. O W.S.B.F.C. ❑ Temporary Construction Meter ❑ Turn on Charge Y Wit, t " ❑ Uncollected Account -Name ❑ Inspection Fee - Tract.- g'- Fee - S. O Plan Check Fees Water 1 Sewer.- Tract - �"� a, �.', A ? O 'Bond Payment - A.D. - Bond 'c ' -Assmt.`� t ❑ Customer Deposit ;, ❑Other 3 "' isoa a ? �.-. ic• ts M n Sr.kNr'.aTOTAL •'t ar�`i r4�Y` �_ ..s rF as°- 'L. > - y, . d• r 'Remarks: Y. . - �•'. ._ , S -: �ro�ri h ��� ��� yd"S�wJy � f� �`c c'%%: a,• 'i' .}:r } -r �..„ v ���... a3 s`�k ❑Copy to: Cash �Waterse,rvice ' Check Money Cashier OrderCVWD-438(11189) r; r ':•:� ^':.''M� :.�•.:�n.. � � .• •� ri. .Rig/..: COACHELLA,VALLEY WATER DISTRICT CASH RECEIPT DETAIL�� .45430. !!. _�. /moi Received From:—. - --- 7 f Date D f' i ._An M 177- 4'' a •tom Address: • f Account No."194 Lots) Tract Service Address a A !"'� I1'1 i rz c �_i G.A. Code G!A(eter(s) $ ; y GSe vices) - ❑ Backflow(s) O House Lateral(s) ' ❑ DetectorCheck(s) O Meter Surcharge natation Capacity Charge d"l �'55 J O W.S.B.F.C. ❑ Temporary Construction Meter ❑ Turn on Charge Y Wit, t " ❑ Uncollected Account -Name ❑ Inspection Fee - Tract.- g'- Fee - S. O Plan Check Fees Water 1 Sewer.- Tract - �"� a, �.', A ? O 'Bond Payment - A.D. - Bond 'c ' -Assmt.`� t ❑ Customer Deposit ;, ❑Other 3 "' isoa a ? �.-. ic• ts M n Sr.kNr'.aTOTAL •'t ar�`i r4�Y` �_ ..s rF as°- 'L. > - y, . d• r 'Remarks: Y. . - �•'. ._ , S -: �ro�ri h ��� ��� yd"S�wJy � f� �`c c'%%: a,• 'i' .}:r } -r �..„ v ���... a3 s`�k ❑Copy to: Cash �Waterse,rvice ' Check Money Cashier OrderCVWD-438(11189) 0 RUSSIA u ouvC� T2EE - T GAL, -� ,vc'Ica Vin : rt -Tl 77-C S . cl i s DR�V'EWAy EARTH SYSTEMS CONSULTANTS S.C. IMFBUENA ENGINEERS DIV. 79-811 B Country Club brive Bermuda Dunes, CA 92201 � (619) 345-1588 Client Name Client Address Client Phone DATE JOB NO. ,B7 356 4-,00�'l PROJECT ,5'Y - 61/0 UEn//Dll D i'1-1ZE Z LOCATION G/9 OU „>rl A FIELD TESTING ' CONTRACTOR /yl • � CoNs%2ucTie f% OWNER WEATHER TEMP. oat AM o at PM PRESENT AT SITE ,. M41eild (J1oAD1jd 4012- ZA,) . P� TEST NUMBER TEST LOCATION LOT NO. ELEVATION FIELD TESTING ' REFERENCE CURVE MOISTURE CONTENT % DRY DENSITY Ibs./Cu. ft. MAXIMUM DRY DENSITY % MAXIMUM DRY DENSITY Ibs./cu. ft. OPTIMUM MOISTURE CONTENT % 4012- ZA,) . P� q° AN /0146 _4c7AlrJIWl LeALL- VAC A14 I S4 6Vo joy ('60 I "WE . � N Q- tAAUt 0;CT*X A✓cnFrL)A QAmcAEL REMARKS: p TL- / 0 1-Y-0 a 6 hJ S iT n 5''S //V -tm/ ee� , fat/ A -4D 1J&19. M— /i✓eg ooTin/bS L Iffy fin/. s/W6 /A M,AX. /- II.To T// 15 5 1.,A�, 4T 04 Bo✓E 6 %c Wn N cC ipBGE tea„ vF CLIENT REPRESENTATIVE SIGNATURE FIELD REPORT TECHNICIANS SIGNATURE .� 4" TITLE 24 REPORT FOR: Single Family Residence 54640 Avenida Ramirez La Quinta, Ca. PROJECT DESIGNER: Blake Buschlen 117.55 East Broadway Whittier, Ca. 90601 (2 13) 695-4724 ��O �X M. Jordan REPORT PREPARED BY: Math/Tec, Inc. - Benito Ramirez 118 S. Catalina Avenue Suite C Redondo Beach; Ca. 90277 (213) 374-8959 Job Number: 91185 / BB185 Date: 9./19/1991 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report... This program has interim approval and is authorized by the California Energy Commission for use with the Second Generation Nonresidential Building Energy Efficiency Standards for Nonresidential Occupancies.. Second Generation Residential Occupancies shown to comply with this program conform to the results produced by the Public Domain Point System, developed by the California Energy Commission. This program developed by Gabel Dodd Associates (415) 428-0803. Table Of Contents for Title 24 Report ------------------------------------- CoverPage.......................................................... 1 Tableof Contents ................................................... 2 Form CF -1R Certificate of Compliance: Residential ................... 3 Form P -2R Point System Summary ...................................... 6 Form MF -1R Mandatory Measures Checklist: Residential ................ 7 Form WS -1R Points Thermal Mass Worksheet ............................ 9 Form WS -2R Interpolation Worksheet .................................. 10 Form S Shading Coefficient (SC) Worksheet ........................... 11 Domestic Hot Water Worksheet ........................................ 13 Form WS -4 HVAC System Summary Sheets ................................ 14 HVAC Zone & Space Loads Summary ..................................... 15 Form CF -3 Construction Assemblies ................................... 18 CERTIFICATE OF COMPLIANCE: Residential (part 1 of 3) CF -1R page 3 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- PROJECT ADDRESS 54640 Avenida Ramirez La Quinta, Ca. GENERAL INFORMATION Compliance Method: Climate Zone: Total Conditioned Floor Area: Building Occupancy: Front Entry Orientation: Number of Dwelling Units: Floor Construction Type: Infiltration Control: BUILDING SHELL INSULATION Component Area R-13 Wall w/1" Rigid 1511 R-30 Roof/Gyp Ceiling 1835 Exposed Slab 430 Carpeted Slab 1404 Job #: 91185 / BB185 Point System 15 1835 sqft Single Fam Det West 1 Slab Standard U -Value Location/Comments ------- ------------------------------------ 0.0514 Residence 0.0355 Residence 0.9000 Residence/Insul= R-0.0 0.7200 Residence/Insul= R-0.0 THERMAL MASS Thick Mass Material Area (in) Type Location/Description --------------------- ---- ------------ ------------------------------ Concrete, Heavyweight 431 3.500 Exposed Residence/Int Mass Concrete, Heavyweight 1404 3.500 Covered Residence/Int Mass CERTIFICATE OF COMPLIANCE: Residential (part 2 of 3) CF -1R page 4 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Documentation: Math/Tec, Inc. - Benito Ramirez -------------------------------------------------------- Building Permit No Checked By Date (User # 1075) -------------------- GLAZING Glass w/Int Location Orient Area Type U -Val SC Shade. Description --------- ------ ----- ------ ----- ----- ----- ----------------------- Residence West 12.0 Double 0.65 0.88 0.33 Double/Light Blinds West 24.0 Double 0.65 0.88 0.33 Double/Light Blinds East 80.0 Double 0.65 0.88 0.33 Double/Light Blinds East 6.0 Double 0.65 0.88 0.75 Double/Nonwhite Drapes North 33.0 Double 0.65 0.88 0.33 Double/Light Blinds South 54.0 Double 0.65 0.88 0.33 Double/Light Blinds South 12.0 Double 0.65 0.88 0.33 Double/Light Blinds SHADING (for Glazing above) Over Location Exterior Device SC hang Framing Type --------- ------------------------ ---- ---- ----------------------- Residence 50 % Bug Screen 0.84 1.5 Metal w/o Mullions 50 % Bug Screen 0.84 0.0 Metal w/o Mullions 50 % Bug Screen 0.84 0.0 Metal w/o Mullions 50 % Bug Screen 0.84 0.0 Metal w/o Mullions 50 % Bug Screen 0.84 1.5 Metal w/o Mullions 50 % Bug Screen 0.84 1.5 Metal w/o Mullions 50 % Bug Screen 0.84 1.5 Metal w/o Mullions CERTIFICATE OF COMPLIANCE: Residential (part 3 of 3) CF -1R page 5 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez - I Date (User # 1075) --------------------------------------------------------------------------- HVAC SYSTEMS Minimum Output Duct Duct Manufacturer/Model No. System Type Efficiency (Btuh) Location RVal (or approved equal) ----------- ---------- ---------------------- ---- ----------------------- Electric 3.410 HSPF 36000 Vent. Attic Space 6.3 Lennox ECB18-10 Heat Pump 9.550 SEER 48000 Vent. Attic Space CHP15-5** Zone Furnace Max: Cooling Exception: HOT WATER SYSTEMS System Type ------------------- Electric Resistance 1.3 x [ 29560 Btuh + (10 x 1835 sqft)] = 62283 Btuh CFM Cooling (see Load Calcs) requires Btuh Tank Manufacturer/Model No. # of Energy R-12 Volume (or approved equal) Sys Credits Blanket ----------------------------- ----- ------- ------- 45.0 Rheem 81V -52D (SE) 1 0 Y COMPLIANCE STATEMENT This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20, Chapter 2, Subchapter 4, Article 1 of the California Administrative Code. This certificate has been signed by the individual with overall design responsibility and the building owner, who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. When this Certificate of Compliance is submitted for a single building plan to be built in multiple orientations, all building conservation features which vary are indicated in the Special Features/Remarks section. DESIGNER Blake Buschlen 11755 East Broadway Whittier, Ca. 90601 (213) 695-4724 License No: Signed: (Date) DOCUMENTATION AUTHOR Math/Tec, Inc. - Benito Ramirez 118 S. Catalina Avenue Suite C Redondo Beach, Ca. 90277 (213) 374 - Signed• (Date) Certification Number: RE -9 -4033 BUILDING OWNER M. Jordan Signed: (Date) ENFORCEMENT Name: Agency: Telephone:_ Signed: AGENCY (Date) ` POINTS SYSTEM SUMMARY: CLIMATE --------------------------------------------------------------------------- ZONE 15 P -2R page 6 of 23 Project: Single Family Residence COMPLY 24 v 3.10 Designer: Blake Buschlen Building Permit No Location: La Quinta Date: 9/19/1991 Checked By Documentation: Math/Tec, Inc. - Benito Ramirez Date (User # 1075) --------------------------------------------------------------------------- BUILDING DATA ------------- Conditioned Floor Area 1835 sqft Number of Stories 1 Occupancy Type Single Fam Det SCORE CARD Measure Points ------------------------- 1. Roof Insulation ------- 0.0355 (U -Value) ------ -2 2. Wall Insulation 0.0514 (U -Value) 3 3. Raised Floor Insulation 0.0000 (U -Value) 3a. Controlled Vent Crawlspace 0.0 (R -Value) -> 0 4. Slab Edge Insulation 0.7655 (f2 factor)_ 5. Infiltration Standard 0 6. Glass Heat Loss 0.65 12.0% 5 Sum 1-6 6 7. Shade Open Area % Glass SC OH Eff ------------ a. North 33.0 1.8 -------- x 0.74 ----- = 1.3 0 b. East 86.0 4.7 x 0.74 x 1.00 = 3.5 -1 c. South 66.0 3.6 x 0.74 x 0.84 = 2.3 0 d. West 36.0 2.0 x 0.74 x 0.96 = 1.4 0 e. Skylight 0.0 0.0 x 0.00 = 0.0 0 8. Shade Closed Area % Glass SC OH Eff % ----- ------------ a. North 33.0 1.8 -------- x 0.28 = 0.5 0 b. East 86.0 4.7 x 0.30 x 1.00 = 1.4 0 c. South 66.0 3.6 x 0.28 x 0.64 = 0.6 3 d. West 36.0 2.0 x 0.28 x 0.94 = 0.5 4 e. Skylight 0.0 0.0 x 0.00 = 0.0 0 9. Interior Thermal Mass 2.46 0 10. Exterior Wall Mass 0.00 0 Sum 7-10 6 11. Heating System 3.410 HSPF x 0.84 Duct Eff = 2.86 Eff HSPF -2 Zonal Control: No. 12. Cooling System 9.550,SEER x 0.83 Duct Eff = 7.93 Eff SEER 9 13. Water Heating (see DHW Worksheet) _ -18 Point Total: 1 MANDATORY MEASURES CHECKLIST (part 1 of 2) MF -1R page 7 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Enforcement o Sec. 2-5352(a): Minimum ceiling insulation R-19 weighted average. * o Sec. 2-5352(b): Loose fill insulation manufacturers labeled R -Value. o Sec. 2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). * o Sec. 2-5352(k): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. o Sec. 2-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. o Sec. 2-5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. o Sec. 2-5317: Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and sealed. o Sec. 2-5352(e): Special infiltration barrier installed to comply with Sec. 2-5351 meets CEC quality standards. o Sec. 2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST (part 2 of 2) MF -1R page 8 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- HVAC AND PLUMBING SYSTEM MEASURES Enforcement o Sec. 2-5352(g) and 2-5303: Space conditioning equipment sizing: attach calculations. o Sec. 2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. o Sec. 2-5316(a): Ducts constructed, installed and insulated per Chapter 10, 1976 UMC. * o Sec. 2-5316(b): Exhaust systems have damper controls. o Sec. 2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. o Sec. 2-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. o Sec. 2-5352(i): Water heater insulation blanket (R-12 or greater) for storage & backup tanks for solar water heating systems; first 5 feet of pipes closest to tank insulated (R-3 or greater). o Sec. 2-5312(Exception I): Pipe insulation on steam and steam condensate return & recirculating piping. o Sec. 2-5318(d): Swimming Pool Heating 1. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. LIGHTING AND APPLIANCE MEASURES o Sec. 2-5352(j): Lighting.- 25 lumens/watt or greater for general lighting in kitchens and bathrooms. o Sec. 2-5314(c): Gas fired appliances equipped with intermittent ignition devices. o Sec. 2-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. • THERMAL MASS WORKSHEET WS -1R page 9 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- ------------------ INTERIOR THERMAL MASS Mass Material Thick ---------------------- ----- Concrete, Heavyweight 3.50 Concrete, Heavyweight 3.50 INTERIOR MASS FACTOR Sides Wall Exposed U -Value ------- ------- 1 0 4509.8 IMC / Interior Interior Mass Mass Mass Area Factor -------- Capacity -------- ------ 431.0 x 4.6 = 1982.6 1404.0 x 1.8 = 2527.2 TOTAL 4509.8 1835 sqft = 2.46 * Mass listed above with a Wall U -Value denotes the Interior Mass credit for Exterior Mass Walls, and are repeated below for Exterior Mass credit. 0 Sides Exposed indicates mass covered with surface material >= R-2. EXTERIOR MASS WALLS Exterior Exterior Sides Wall Mass Mass Mass Mass Material Thick Exposed U -Value Area Factor Capacity INTERPOLATION, WEIGHTED AVERAGE & ADDITION WORKSHEET WS -2R page 10 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- ------------------ INTERPOLATION Point Point Point Score Actual Value Score Score Value Value Point Item 1 Value 1 2 1 2 1 Score ------- ----- Roof 4 +( ------ 0.0355 ----- - 0.02) x ----- ( -4 - ----- 4) /( ----- 0.04 ----- - 0.02) ----- _ -2 Wall 6 +(.0.0514 - 0.04) x ( 1 - 6) /( 0.06 - 0.04) = 3 Slab Edge 2 +( 0.7655 - 0.70) x ( -1 - 2) /( 0.80 - 0.70) = 0 Glass Type 2 5 +(12.0436 -12.00) x ( 3 - 5) /(13.00 -12.00) = 5 N Shade Open 0 +( 1.3369 - 1.00) x ( 0 - 0) /( 2.00 - 1.00) = 0 E Shade Open -1 +( 3.4842 - 3.00) x ( -1 - -1) /( 4.00 - 3.00) _ -1 S Shade Open 0 +( 2.2545 - 2.00) x ( 0 - 0) /( 3.00 - 2.00) = 0 W Shade Open 0 +( 1.4051 - 1.00) x ( 0 - 0) /( 2.00 - 1.00) = 0 N Shade Clsd 1 +( 0.5014 - 0.00) x ( 0 - 1) /( 1.00 - 0.00) = 0 E Shade Clsd 1 +( 1.4226 - 1.00) x ( -2 - 1) /( 2.00 - 1.00) _ -0 S Shade Clsd 6 +( 0.6424 - 0.00) x ( 2 - 6) /( 1.00 - 0.00) = 3 W Shade Clsd 6 +( 0.5166 - 0.00) x ( 2 - 6) /( 1.00 - 0.00) = 4 Int Mass -1 +( 2.4577 - 2.00) x ( 0 - -1) /( 2.50 - 2.00) _ -0 Heating -2 +( 2.8644 - 2.75) x ( -1 - -2) /( 3.41 - 2.75) _ -2 Cooling 0 +( 7.9265 - 7.00) x ( 10 - 0) /( 8.00 - 7.00) = 9 WEIGHTED AVERAGE POINTS Type 1 Type 2 Type 3 Total Average Item --------- Points Area Points ------ ---- ------ Area ---- Points ------ Area ---- Area ----- Points ------- SHADING COEFFICIENT (SC) WORKSHEET FORM S page 11 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- GENERAL INFORMATION 1. Glazing Type: Double 3. Framing Type: Metal w/o Mullions 5. Framing/Mullion Factor: 0.88 (from Table G-10) 6. Interior Shade Type: Double/Light Blinds 7. SC Shade Open: 0.88 (from Table G-9 or show calculation) 8. SC Shade Closed: 0.33 (from Table G-9 or show calculation) GLAZING, INTERIOR SHADE & FRAMING 9a. 0.88 (SC #7) x 0.88 (FMF #5) = 0.77 SC Shade Open 10a.0.33 (SC #8) x 0.88 (FMF #5) = 0.29 SC Shade Closed EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen 11. SC Exterior Shade: 0.84 (from Table G-11 or manufacturer's data) 12. [(0.84 (SC #11) x 0.25) + 0.75] x 0.77 (SC #9a) = 0.74 SC Shade Open 13. [(0.84 (SC #11) x 0.25) + 0.75] x 0.29 (SC #10a) = 0.28 SC Shade Closed �IM:$:MP.1Z[on a-XQ 31 Glass Ovrhng Dist Glass Proj OH Factor OH Factor Orientation Area Depth Above Height Ratio Shade Open Shade Clsd ----------- West ----- 12.0 ------ 1.5 / ----- ( 0.1 ------ + 4.0) ----- = 0.37 ---------- 0.89 ---------- 0.83 South 54.0 1.5 / ( 0.1 + 3.0) = 0.48 0.84 0.63 South 12.0 1.5 / ( 0.1 + 4.0) = 0.37 0.88 0.69 SHADING COEFFICIENT (SC) WORKSHEET FORM S page 12 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Documentation: Math/Tec, Inc. - Benito Ramirez -------------------------------------------------------- GENERAL INFORMATION Building Permit No Checked By Date (User # 1075) -------------------- 1. Glazing Type: Double 3. Framing Type: Metal w/o Mullions 5. Framing/Mullion Factor: 0.88 (from Table G-10) 6. Interior Shade Type: Double/Nonwhite Drapes 7. SC Shade Open: 0.88 (from Table G-9 or show calculation) 8. SC Shade Closed: 0.75 (from Table G-9 or show calculation) GLAZING, INTERIOR SHADE & FRAMING 9a. 0.88 (SC #7) x 0.88 (FMF #5) = 0.77 SC Shade Open 10a.0.75 (SC #8) x 0.88 (FMF #5) = 0.66 SC Shade Closed EXTERIOR SHADE Exterior Shade Type: 50 % Bug Screen 11. SC Exterior Shade: 0.84 (from Table G-11 or manufacturer's data) 12. [(0.84 (SC #11) x 0.25) + 0.75] x 0.77 (SC #9a) = 0.74 SC Shade Open 13. [(0.84 (SC #11) x 0.25) + 0.75] x 0.66 (SC #10a) = 0.63 SC Shade Closed --------------------------------------------------------------------------- OVERHANG FACTOR Glass Ovrhng Dist Glass Proj OH Factor OH Factor Orientation Area Depth Above Height Ratio Shade Open Shade Clsd ----------- ----- ------ ----- ------ ----- ---------- ---------- NO OVERHANGS DHW WORKSHEET ONE: STORAGE TYPE GAS OR ELECTRIC page 13 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- A EQUIPMENT DATA 1 Water heater type SE Enter SG or SE 2 Manufacturer & 70.0 F, see Table 1 3 Model number 50 Rheem 81V -52D (SE) 4 Ignition device IID GP, gas pilot or IID, int. ignition device 5 Tank volume 45.0 Total gallons, from CEC Appliance Directory 6 Recovery efficiency 99.7 Percent from CEC Appliance Directory 7 Standby loss 0.7 Percent/hour, from CEC Appliance Directory 8 Rated input 39249 Btu/hr, from CEC Appliance Directory 3.413 x 3 x 0.001 (1 kWh = 3413 Btu) 9 Number of Heaters 1 From building plans (total) 10 Insulation Jacket Y (Y/N) R-12 insulating jacket on the plans B OPERATING DATA --------------------------------------------------------- 1 Climate Zone 15 See Appendix D 2 Water heating budget 18700 KBtu/yr/unit, see Table 1 3 Tank set temp. 140 F, fixed input 4 Water main temp. 70.0 F, see Table 1 5 Daily hot water load 50 50 or 35 gallons/unit, see Table 1 6 Ambient air temp. 72.6 F, see Table 1 7 Adj Standby Losses 0.0055 See Table 2 or Appendix B 8 No. dwelling units 1 From building plans (total) 9 Number of pumps 0 From building plans 10 Pumping energy 0.0 Watt-hr/yr per Pump, see Table 3 C WATER HEATING ENERGY CREDITS --------------------------------------------------------------------------- 1 Credit name See Table 5 2 Annual savings 0.0 KBtu/yr/dwelling unit, see Table 5 D CALCULATE ANNUAL WATER HEATING ENERGY (KBtu/yr) 1 Recovery load 10539.4 ([B5 x 8.25 x(140-B4)x 365 x 0.001]-C2)x B8 2 Recovery energy 10571.1 D1 / A6 3 Standby loss energy 1162.6 (24 - [(D2 x 1000)/(A8 x A9 x 365)]? x 8.25 x A5 x B7 x 365 x (140-B6) x 0.001 x A9 4 Pumping energy 0.0 B9 x B10 x 3.413 x 3 x 0.001 5 Total energy 35200.9 GAS SYSTEMS: (D2 + D3 + D4) / B8 ELECTRIC: ([(D2 + D3) x 3] + D4) / B8 6 Water heating budget comparison -16500.9 KBtu/yr/unit B2 - D5 7 Water heating budget -18.0 Points (D6 / Floor Area) x 2 x B8 HVAC SYSTEM SUMMARY SHEET WS -4 page 14 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- ------------------ HEATING Heating System Name: System Type: Output Capacity: Rated SSE or COP: Supply Air Temperature: COOLING Cooling System Name: System Type: Total Output Capacity: Sensible Output Capacity: Latent Output Capacity: Rated EER: Coil Bypass Factor: Economizer: Supply Air Temperature: FANS Supply Air CFM: Fan Type: Fan Multiplier: Brake Horsepower: Motor Efficiency: Drive Efficiency: DUCTS Supply Duct Heat Gain: Return Duct Heat Gain: Supply Duct Air Leakage: Return Duct Air Leakage: Lennox ECB18-10 Electric Resistance 36000 Btu/hr 1.000 105 F CHP15-5** Heat Pump 48000 Btu/hr 36000 Btu/hr 12000 Btu/hr 8.300 0.100 No 55 F 1600 cfm Draw -Through 1 0.70 71.5 100.0 0.0 % 0.0 % a 0.0 % 0 0.0 % 0 'HVAC ZONE HEATING & COOLING LOAD SUMMARY page 15 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Documentation: Math/Tec, Inc. - Benito Ramirez ------------------------------------------------------- HVAC ZONE DESCRIPTION HVAC Zone Name: Heating System Name: Cooling System Name: System Multiplier: Heating Schedule: Cooling Schedule: Fan Schedule: Peak Load Method: Relative Humidity: SPACES IN THIS ZONE PEAK Residence (Jan 12am) TOTAL SPACE LOAD Bypass Ventilation Air ( 0 cfm) Supply Duct Conduction Supply Duct Leakage Supply Fan Heat Gain EFFECTIVE SPACE LOAD Ventilation ( 0 cfm) Return Air Lighting Gain Return Duct Conduction Return Duct Leakage Return Fan Heat Gain TOTAL SYSTEM LOAD SYSTEM PERFORMANCE AT DESIGN CONDITIONS HEATING 32053 32053 0 0 0 -2493 29560 0 0 0 -0 29560 36000 Building Permit No Checked By Date (User # 1075) -------------------- HVAC to Residence Lennox ECB18-10 CHP15-5** 1 Residential Heating Residential Cooling Residential HVAC & Fans COINCIDENT 50 % a COOLING PEAK SENSIBLE LATENT ------------ ------ (Aug 2pm) 29375 1032 -------- ------ 29375 1032 0 cfm) 0 -0 0 0 0 2493 31868 1032 0 cfm) 0 -0 0 0 0 0 0 31868 1032 2.7 tons 0.1 tons 35086 8147 2.9 tons 0.7 tons RESIDENTIAL SPACE HEATING LOAD SUMMARY page 16 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito --------------------------------------------------------------------------- Ramirez I Date (User # 1075) Space Name: Residence Design Indoor Dry Bulb Temperature: 70 F Design Outdoor Winter Dry Bulb Temperature: 29 F Design Temperature Difference: 41 F Conduction Area U -Value TD Btu/hr ----------------------- R-13 Wall w/1" Rigid ------ 1511.0. x ------- ---- 0.0514 x 41.0 ------ = 3184 Double/Light Blinds 215.0 x 0.6500 x 41.0 = 5730 Double/Nonwhite Drapes 6.0 x 0.6500 x 41.0 = 160 R-30 Roof/Gyp Ceiling 1835.0 x 0.0355 x 41.0 = 2673 Exposed Slab Perim = 46.0 x 43 = 1978 Carpeted Slab Perim ,= 136.0 x 43 = 5848 Infiltration: 1.00 x 0.018 x 1835 sqft x 9.5 ft x 1.00 AC x 41.0 = 12865 TOTAL HOURLY HEAT LOSS FOR SPACE 32053 SUPPLY AIR QUANTITY ------------------- Heating: 32053 Btu/hr / [1.10 * (105 F Supply - 65 F TStat)] = 728 cfm RESIDENTIAL SPACE COOLING LOAD SUMMARY page 17 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. --------------------------------------------------------------------------- - Benito Ramirez I Date (User # 1075) Space Name: 1.00 x 1835.0 Residence = 0 Design Indoor Dry Bulb Temperature: Area SGF 78 F Area Design Outdoor Summer Dry Bulb Temperature: Btu/hr ------ 112 F Blinds Design Temperature Difference: ---- --- 3.3 x 15 + 34 F --- 73] Conduction Area U -Value DETD Btu/hr ----------------------- R-13 Wall w/1" Rigid ------ 1511.0 x ------- 0.0512 ---- x 29.6 = ------ 2289 Double/Light Blinds 215.0 x 0.6179 x 34.0 = 4517 Double/Nonwhite Drapes 6.0 x 0.6179 x 34.0 = 126 R-30 Roof/Gyp Ceiling 1835.0 x 0.0347 x 50.0 = 3182 Infiltration: 1.00 x 0.018 x 1835 sqft x 9.5 ft x 1.00 AC x 34.0 = 10669 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 29375 Latent Gain Op Frac. -------- Area ------ Shaded Btu/hr ------ Unshaded 1.00 x 1835.0 Solar Gain = 0 Orient. Area SGF 1835.0 Area SGF SC ---- Btu/hr ------ ----------------------- Double/Light Blinds --------- West [ ---- --- 3.3 x 15 + ---- 8.7 x --- 73] x 0.28 = 191 Double/Light Blinds West [ 0.0 x 15 + 24.0 x 73] x 0.28 = 488 Double/Light Blinds East [ 0.0 x 15 + 80.0 x 73] x 0.28 = 1628 Double/Nonwhite Drapes East [ 0.0 x 15 + 6.0 x 73] x 0.63 = 278 Double/Light Blinds North [ 0.0 x 15 + 33.0 x 15] x 0.28 = 138 Double/Light Blinds South [ 54.0 x 15 + 0.0 x 32] x 0.28 = 226 Double/Light Blinds South [ 12.0 x 15 + 0.0 x 32] x 0.28 = 50 Internal Gain ----------------------- Op Frac. -------- Area ------ Heat --------- Gain Conv. ----- Btu/hr ------ Lighting 1.00 x 1835.0 x 0.500 x 3.413 = 3131 Equipment 1.00 x 1835.0 x 0.250 x 3.413 = 1566 Occupants 0.75 x 1835.0 x 225 / 300 = 1032 TOTAL HOURLY SENSIBLE HEAT GAIN FOR SPACE 29375 Latent Gain Op Frac. -------- Area ------ Heat Gain Conv. --------- ----- Btu/hr ------ ----------------------- Equipment 1.00 x 1835.0 x 0.000 x 3.413 = 0 Occupants 0.75 x 1835.0 x 225 / 300 = 1032 TOTAL HOURLY LATENT HEAT GAIN FOR SPACE 1032 SUPPLY AIR QUANTITY ------------------- Cooling: 29375 Btu/hr / [1.08 * ( 78 F TStat - 55 F Supply)] = 1183 cfm iCONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 18 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- ------------------ Assembly Name: R-13 Wall w/1" Rigid Assembly Type: Wall Assembly Tilt: 90 deg (Vertical) Framing Percentage: 15.0 % Framing Material: Softwood, Douglas Fir -Larch Calculation for Framing Adjustment Summer U -Value 0.0458 x 0.85 + 0.0814 x 0.15 = 0.0512 Winter U -Value 0.0460 x 0.85 + 0.0820 x 0.15 = 0.0514 OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Stucco, Wood Shingles Weight: 12.7 lb/sqft Heat Capacity: 2.96 R -Value 19.54 19.45 U -Value 0.0512 0.0514 Th R -Value Construction Components Fr (in) Summer Winter --------------------------------------------------------------------------- Outside Air Film 0.25 0.17 1. Stucco 0.875 0.17 0.17 2. Membrane, Vapor -Permeable Felt 0.010 0.06 0.06 3. Celotex Rigid Polyisocyanurate Foam Brd 1.000 7.20 7.20 4. Insulation, Mineral Wool, R-13 * 3.500 13.00 13.00 5. Gypsum or Plaster Board 0.500 0.45 0.45 6. 7. 8. 9. Inside Air Film --------------------------------------------------------------------------- 0.68 0.68 Total 21.82 21.74 Framing Percentage: 15.0 % Framing Material: Softwood, Douglas Fir -Larch Calculation for Framing Adjustment Summer U -Value 0.0458 x 0.85 + 0.0814 x 0.15 = 0.0512 Winter U -Value 0.0460 x 0.85 + 0.0820 x 0.15 = 0.0514 OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Stucco, Wood Shingles Weight: 12.7 lb/sqft Heat Capacity: 2.96 R -Value 19.54 19.45 U -Value 0.0512 0.0514 `CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 19 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- ------------------ Assembly Name: R-30 Roof/Gyp Ceiling Assembly Type: Roof Assembly Tilt: 0 deg (Horizontal Roof) Framing Percentage: 10.0 % Framing Material: Softwood, Douglas Fir -Larch Calculation for Framing Adjustment Summer U -Value 0.0299 x 0.90 + 0.0778 x 0.10 = 0.0347 Winter U -Value 0.0304 x 0.90 + 0.0815 x 0.10 = 0.0355 OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 9.2 lb/sqft Heat Capacity: 2.71 R -Value 28.84 28.14 U -Value 0.0347 0.0355 Th R -Value Construction Components --------------------------------------------------------------------------- Fr (in) Summer Winter Outside Air Film 0.25 0.17 1. Roofing, Asbestos -Cement Shingles 0.250 0.21 0.21 2. Plywood 0.500 0.63 0.63 3. Air Space 12.000 1.00 0.93 4. Insulation, Mineral Wool, R-30 * 9.500 30.00 30.00 5. Gypsum or Plaster Board 0.500 0.45 0.45 6. 7. 8. 9. Inside Air Film --------------------------------------------------------------------------- 0.92 0.61 Total 33.46 32.87 Framing Percentage: 10.0 % Framing Material: Softwood, Douglas Fir -Larch Calculation for Framing Adjustment Summer U -Value 0.0299 x 0.90 + 0.0778 x 0.10 = 0.0347 Winter U -Value 0.0304 x 0.90 + 0.0815 x 0.10 = 0.0355 OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 9.2 lb/sqft Heat Capacity: 2.71 R -Value 28.84 28.14 U -Value 0.0347 0.0355 'CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 20 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- Assembly Name: Carpeted Slab Assembly Type: Floor Assembly Tilt: 180 deg (Horizontal Floor) Framing Percentage: 0.0 Framing Material: NONE OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 40.9 lb/sqft Heat Capacity: 9.01 R -Value 3.22 3.45 U -Value 0.3106 0.2899 Th R -Value Construction Components --------------------------------------------------------------------------- Fr (in) Summer Winter Outside Air Film 0.25 0.17 1. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 2. Flooring, Carpet and Fibrous Pad 0.250 2.08 2.08 3. 4. 5. 6. 7. 8. 9. Inside Air Film --------------------------------------------------------------------------- 0.61 0.92 Total 3.22 3.45 Framing Percentage: 0.0 Framing Material: NONE OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 40.9 lb/sqft Heat Capacity: 9.01 R -Value 3.22 3.45 U -Value 0.3106 0.2899 `CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 21 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- Assembly Name: Exposed Slab Assembly Type: Floor Assembly Tilt: 180 deg (Horizontal Floor) Framing Percentage: 0.0 Framing Material: NONE OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 40.9 lb/sgft Heat Capacity: 9.00 R -Value 1.19 1.42 U -Value 0.8403 0.7042 Th R -Value Construction Components Fr (in) Summer Winter --------------------------------------------------------------------------- Outside Air Film 0.25 0.17 1. Concrete, 140 lb, Not Dried 3.500 0.28 0.28 2. Flooring, Asphalt, Lino, Vinyl or Rubber 0.010 0.05 0.05 3. 4. 5. 6. 7. 8. 9. Inside Air Film --------------------------------------------------------------------------- 0.61 0.92 Total 1.19 1.42 Framing Percentage: 0.0 Framing Material: NONE OVERALL VALUES ADJUSTED FOR FRAMING ------------------------------- Sketch of Construction Assembly Absorptivity: 0.70 Roughness: Concrete, Asph. Shingles Weight: 40.9 lb/sgft Heat Capacity: 9.00 R -Value 1.19 1.42 U -Value 0.8403 0.7042 'CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 22 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) ----------------------------------------------------- -------------------- Assembly Name: Double/Nonwhite Drapes Assembly Type: Glazing Th R -Value Construction Components Fr (in) Summer Winter --------------------------------------------------------------------------- Outside Air Film 0.25 0.17 1. CEC Double Glazing 0.500 0.69 0.69 2. 3. 4. 5. 6. 7. 8. 9. Inside Air Film 0.68 0.68 --------------------------------------------------------------------------- Framing Percentage: 0.0 % Framing Material: NONE ------------------------------- Sketch of Construction Assembly Winter Shading Coefficient: 0.88 Summer Shading Coefficient: 0.75 Total 1.62 1.54 OVERALL VALUES ADJUSTED FOR FRAMING R -Value 1.62 1.54 U -Value 0.6179 0.6500 'CONSTRUCTION ASSEMBLY COMPLIANCE FORM CF -3 page 23 of 23 --------------------------------------------------------------------------- Project: Single Family Residence I COMPLY 24 v 3.10 Designer: Blake Buschlen Location: La Quinta Date: 9/19/1991 Building Permit No Checked By Documentation: Math/Tec, Inc. - Benito Ramirez I Date (User # 1075) --------------------------------------------------------------------------- Assembly Name: Double/Light Blinds Assembly Type: Glazing Th R -Value Construction Components Fr (in) Summer Winter --------------------------------------------------------------------------- Outside Air Film 0.25 0.17 1. CEC Double Glazing 0.500 0.69 0.69 2. 3. 4. 5. 6. 7. 8. 9. Inside Air Film 0.68 0.68 --------------------------------------------------------------------------- Framing Percentage: 0.0 % Framing Material: NONE ------------------------------- Sketch of Construction Assembly Winter Shading Coefficient: 0.88 Summer Shading Coefficient: 0.33 Total 1.62 1.54 OVERALL VALUES ADJUSTED FOR FRAMING R -Value 1.62 1.54 U -Value 0.6179 0.6500