Loading...
14-488 (RER)�- Q�i VOICE (760) 777-7125 78-495 CALLE TAMPICO ' V FAX (760) 777-7011COMMUNITY LA QUINTA, CALIFORNIA 92253 DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 7/29/2014 Application Number: RER-14-488 Owner: Property Address: 54925 AVENIDA RAMIREZ GB INLAND PROPERTIES II, LLC APN: 774295021 110 N. LINCOLN AVE#100 Application Description: CODE CASE - REMODEL & BATHROOM & GARAGE ADDITION CORONA, CA 92882 Property Zoning: Application Valuation: $20,000.00 Applicant: Contractor: , KIM QUON DALE E GRIFFIN CO DBA GRI 3266 SPRUCE ST. 110 N LINCOLN AVE STE 100 LAKE ELSINORE, CA 92530 CORONA, CA 92882 (951)547-3500 Llc. No.: 605391 - - - - - - - - -'- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: B License No.: 605391 Dateh / ContractorA lir OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. BAP.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certifica_e of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance o!f,e.wilkk for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ _ I certify that in the performance a'the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree tdat, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with tq se provisions. //jj Date ' l� ApplicantAl WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta,.its officers, agents, and employees for any act or omission related tathe work being performed under or following issuance of this permit. 2. Any permit issued as a result of this apprication becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county oriinances and state laws relating to building construction, and hereby authorize represertatives of this city to enter upon the above- mentioned property for inspection purposes Date: r; Signature (Applica it or Agentf ;l r PAID PAID DATE DESCRIPTION; ;;,>a= FINANCIAL ORMATION A00OUNT` t,` a `QTY ;AMOUNT ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $122.98 $0.00 PAID�.BY a �' METHOD .. 4. ,_.. ..RECEIPT # < . . CHECK # CLTD BY :w- DESCRIPTION `1., ACCOUNT <QTY; ';AMOUNT. ,. •PAID ,•,� PAID, DATE ADDITION, EA ADDITIONAL 500 SF PC 101-0000-42600 0 $17.16 $0.00 -';PAID BY ,;METHOD .: _CHECK #. ` CLTD BY �. DESCRIPTION ; : - ACCOUNT QTY . AMOUNT PAID' PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $240.24 $0.00 PAID BY,', METHOD ~a ,,r '. RECEIPT #_ ` CHECK # x. CLTD BY DESCRIPTION ACCOUNT '3 f,. .QTY. w AMOUNT- PAID ' PAID DATE ADDITION, FIRST 100 SF PC 101-0000-42600 0 $168.74 $0.00 ; . 11e "' a :PAID BY i ?, { a ` } wMETHOD ,r RECEIPT #`' CHECK # t' `_CLTD BY ' Total Paid forADDITION: $549.12 $0.00 ;DESCRIPTION A .� .. ACCOUNT = QTY .' : AMOUNT � t ;PAID - {.. PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $1.00 $0.00 -• ;PAID BY, t 4 ts. �' METHOD - ,,' : ;: '- RECEIPT #' ' r '" CH ECK # CLTD BY ,: Total Paid forBUILDING STANDARDS ADMINISTRATION BSA; $1.00 $0.00 Y;':AMOUNT, 'PAIDACCOUNT :PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $143.00 $0.00 t `. M.PAID BY. ' 's `-`• ,' METHOD�- -CLTD F :RECEIPT # ` - - :CHECK # BY d DESCRIPTION „" r . �' ,; `ACCOUNT' _. ..QTY AMOUNT :''PAID " ,PAID DATE RESIDENTIAL, FIRST 1,000SF, PC 101-0000-42600 0 $47.19 $0.00 - PAID BY METHOD = a `.RECEIPT# CHECK # =CLTD BY Total Paid for ELECTRICAL- NEW CONSTRUCTION: $190.19 $0.00 - f DESCRIPTION ._; ACCOUNT-.-Q _ s,..' QTY "AMOUNT,,,, ' PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $47.68 $0.00 ,°PAID BYE .�, _METHOD RECEIPT CHECK # r =CLTD BY - 'DESCRIPTION i ACCOUNT ;QTY+, .-AMOUNT AMOUNT t PAID , PAID DATE, VENT FAN 101-0000-42402 0 $47.68 $0.00 • M F PAID;BY 4 , • <., . METHOD s RECEIPT,# ', 'z' CHECK # =CLTD BY - Total Paid for MECHANICAL: $95.36 $0.00 r- • �� •5: DESCRIPTION, ACCOUNT .y $ QTY AM .. ti " -;:AMOUNT`_ PAID ta' , PAID DATE FIXTURE/TRAP 101-0000-42401 0 $95.36 $0.00 PAID -BYE + '' METHOD'? ,. . r ;RECEIPT:# r'.. CHECK # `" CLTD BY �m DESCRIPTION a _ ...... s - _, .:'ACCOUN1.T _ _ s �' CtTY y .,� .,, 'AMOUNT :.. Y _ PAID _ PAID DATE FIXTURE/TRAP PC 101-0000-42600 0 $47.68 $0.00 = »a PAID -BY" , _ METHOD RECEIPT #` ' -CHECK #' CLTD BY QTY '"AMO 4'. PAID _PAID DATE:DESCRIPTI WATER HEATER/VENT 101-0000-42401 0 $47.68 $0.00 - r = METHODr'RECEIP:T #... 'CHECK # CL `DESCRIPTION i `. `-ACCOUNT".:QTY_ AMOUNT r• s`� PAID.' PAID DATE WATER HEATER/VENT PC 101-0000-42600 0 $14.30 $0.00 PAID BYa i 'c *Tye , z ' "METHOD ,4 RECEIPT # *7<, h CHECK # ' " sr CLTD BY -_ •� DESCRIPTION` =-` , -ACCOUNT-=Y` ;CITY`,`_ ;AIVIOUNT-� _ "PAID PAID;DATE' WATER SYSTEM INST/ALT/REP 101-0000-42401 0 $23.84 $0.00 N PAID;BY= ` Ry METHOD _ f ..RE # k T CEIPT +o CHECK # xr , .. CLTD S DESCRIPTION;-"" , , ,` "'' " ACCOUNT QTY ,;AMOUNT: _ �1 t :PAID PAID DATE WATER SYSTEM INST/ALT/REP PC 101-0000-42600 0 $11.92 $0.00 PAID'"RECEIPT.#,a c''- CHECK # 1, :CLTD BY - Total Paid for PLUMBING FEES: $240.78 $0.00 TOTALS: 00 Bin # Permit # �jq 'Project Address: A. P. Number: Legal Description: Contractor: Address: City, ST, Zip: Telephone: State Lie. # Arch., Engr.,.Designer: Address: City., ST, Zip: Telephone: 0 4 State Lie.#:, Name of Contact Person: V4 ry Telephone # of Contact Person: G( City of La Quinta Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building -Permit Application and Tracking Sheet Owner's Name: &5 i i Address: 11,0W W. A),VOW City, ST, Zip: 6t/c Telephone: -Project Description: 'tZt=:rL4r)no;77_ b1 - City Lie. #; # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted 17,10 Item Amount Structural Calcs. Reviewed, ready for corrections Z Ian Check deposit Truss Calcs. Called Contact Person Z Plan Check Balance. Title 24 Calcs. Plans picked up l V Construction Flood plain plan Plans resubmitted WW Mechanical Grading plan 2"a Review, ready for correcti n /issue Electrical SubcontactorListCalled Contact Pcrsone. i Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- Review, ready for corrections/issue Developer Enpact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue X School Fees'V1 bA. 1,076-451 Total Permat Fees tj`Z2 . 4"t wo- CERTIFICATE OF COMPLIANCE 5 Desert Sands Unified.School District 47950 Dune Palms.Road ¢ BERMUDA DUNES r C/) RANCHO MIRAGE Date 7/29/14 La Quinta, CA 92253 _ t.., INDIAN WELLS PALMDESERT No. 32214 (760) 771-8515. LA QUINTA QINDD,IO Owner GB Inland Properties'll, LLC APN # 774-295-021 Address 110 N. Lincoln Aven, Suite 100 Jurisdiction La Quinta City Corona • Zip 92882 Permit # • „' Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F.' Lot # No. Street S.F. Unit 1 54925 Avenida Ramirez 147 Unit 6 Unit 2 Unit 7 Unit 3 Unit -8 Unit 4 Unit 9 ' Unit 5 Unit 10 4 Comments Bathroom Addition (Previously Unpermitted) 4 At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered pabostwalkways, residential additions under 500 square feet, detached. accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or.Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 147 S.F. or $0.00 have been paid for the property listed above and that . building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Kim Quon • Check No. . Bank Name/Recipient of Certificate Telephone 95101-1271 • Funding Exemp- _ r _ By Dr. Gary Rutherford Superintendent Fee collected /exempte by S n ilvrey Payment Recd a 60.00 ` Signature • l; Q, a� NOTICE: Pursuant to Government Code Section 66020(d)(1), this wi s e to notify you that the 90 -day approval perod in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this protect is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the'Districtfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal - ' Embossed Original - Building Department Applicant Copy - Applicant/Receipt Cooy - Accounting DOC # 201.4-0065740 02/20/2014 08:00. AM Fees: $21.00 Page 1 of 3' Doc T Tax Paid Recorded ir, Official Records RECORDING, REQUESTED BY: County of Mverside rids 365 Larry W. Ward - Assessor, County Clerk & Recorder WHEN RECORDED MAIL DEED AND TAX STATEMENT TO: "This document was electronically submitted • GB INLAND PROPERTIES II, LLC to the County•of Riverside for recording" , Receipted by AGONZALEZ 110 N. LINCOLN AVE. #100 .CORONA, CA 92882 APN 774-295 021-7 TS No:,CA05002407-.13-1 TO No: 100649 TRUSTEE'S, DEED UPON SALE 1) The Grantee herein was not the foreclosing beneficiary. ' 2) The amount of the unpaid debt together with costs was: 3) The amount paid by the Grantee' at the trustee sale was:' $3071192:16 „ $138,1'00.00 4) The documentary transfer tax is: ' 5) Said property is in the•city of:. LA QUINTA• �-- 1�Z - 6)' A. P. N. 774=295-021-7 . "ECEIVED. JUN 2 0 2014 MY OF LA OUINTA COMMUNITY DEVELOPMENT r THIS PAGE ADDED. TO PROVIDE ADEQUATE SPACE FOR RECORDING INFORMATION APN: 774-295-021-7 TS No: CA05002407-13-1 TO 'No: 100649 02-0-0 1 TRUSTEE'S DEED UPON SALE The undersigned Grantor, under penalty of perjury, declares: 1) The Grantee herein was not the foreclosing beneficiary. 2) The amount of the unpaid debt together with costs was: $307,192.16 3) The amount paid by the Grantee at the trustee sale was: $138,100.00 4) The documentary transfer tax is: 5) Said property is in the city of: LA QUINTA 6) A. P. N. 774-295-021-7 and MTC Financial Inc. dba Trustee Corps, herein called "Trustee", as Trustee por as Successor Trustee) of the Deed of Trust hereinafter described, hereby grants and conveys, but wi.hout covenant or warranty, express or implied, to GB INLAND PROPERTIES II, LLC, herein called "Grantee", the real property in the County of Riverside, State of California, described as follows: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF This deed is made pursuant to the authority and powers given to Trustee (or to Successor Trustee) by law and by that certain Deed of Trust dated December 1, 2005, made to ROBERT F MORROW, AN UNMARRIED MAN and recorded on December 6, 2005, as Instrument No. 2005-1007883 of Official Records in the office of the Recorder of Riverside County, CA; Trustee (or Successor Trustee) having complied with all applicable statutory provisions and having performed all of his duties under the said Deed of Trust. All requirements of law and of said Deed of Trust relating to this sale and to notice thereof having been complied with. Pursuant to the Notice of Trustee's Sale, the above described property was sold by Trustee (or Successor Trustee) at public auction on February 6, 2014 at the place specified in said Notice, to Grantee who:was the highest bidder therefore, for $138,100.00 cash, in lawful money of the United States, which has been paid. Dated: MTCfnaI Inc. dba Trustee Corps By. a, Aut&brizei�natory State of CALIFORNIA County -of ORANGE On G.� 1� I before. me, ..i �� Nota Public, ersonall a ` e Notary p y appeared LUPE TABITA who proved to. me on the, basis of satisfactory evidence . to: be the person whose name is subscribed to the within instrument and acknowledged tame thalshe executed the same in p6her authorized. capacity, and that by her signature on the instrument the person, or the entity upon behalf of which the person acted; executed the instrument. I certify under PENALTY OF PERJURY under the laws of the State of CALIFORNIA that the foregoing paragraph is true and correct. WITNESS my hand and official seal. K' DAVID MILLER; ".OoMmisslond�'1893688 Notary Publi; - Cafrfornis Nota�Publicand for said County.and State = orange county A Comm. Ex fifes Jun 25,2014it THIS DOCUMENT! IS FILED FOR RECORD BY TITLE 365 AS AN ACCOMMODATION ONLY. IT HAS NOT BEEN EXAMINEDASE> TO ITS EXEC 014 OR AS TO ITS EFFECT UPON THE mu. APN: 774-295-021-7 TS No: CA05002407-13-1 TO No: 100649 EXHIBIT "A" THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE COUNTY OF RIVER SIDE, STATE OF CALIFORNIA, AND. IS DESCRIBED AS FOLLOWS: LOTS 9 AND 10, BLOCK 310, UNIT 28, SANTA CARMELITA AT VALE.LAQUINTA, AS SHOWN BY MAP ON FILE IN BOOK 19, PAGES 59 AND 60 OF MAPS, RECORDS OF RIVERSIDE COUNTY, CALIFORNIA. TABLE OF CONTENTS TOC Project Title...,....... GB Inland Properties Date..06/20/14 10:15:01 Project Address:....... 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8.1* Documentation Author... Debbie Miner ****** Building Permit # Cal-Kool A/C & Heating 31600 Railroad Canyon Road Plan -Check / Date Canyon Lake, CA 92587 _ 951-244-4412 I Field Check/ Date Climate Zone........:.. 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C &•Heating Run -GB Inland Properties TABLE OF CONTENTS > Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 8 HVAC SIZING........ .... 13 C-_ tCA!S CITY OF LA QUINTA BUILDING & SAFETY CEPT. APPROVE® FOCO STRUCTION DA BY CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title....:..... GB.Inland Properties Date..06/20/14.10:15:01 Project Address........ 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8.l* Documentation Author:.. Debbie Miner ****** I Building Permit # Cal-Kool A/C & Heating 31600 Railroad Canyon Road I Plan Cheek / Date Canyon Lake, CA 92587 951-244-4412 I Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland.Prope-ties II MICROPAS8 ENERGY USE SUMMARY II II Energy Use Standard Proposed Compliance Pe°_cent II II (kTDV/sf-yr) Design Design Margin Impr•Dvement; II II" Space Heating....:..... 29.35 29.37 -0.02 II -0'.1% II Space Cooling ........... 288.06 287.48 0.58 0.2% II II Ventilation Fans...'.... 0.91 II 0.91 0.00 0.0% - II Total 318.32 317.76 0.56 II 0.2% II II *** Building complies with Computer Performance *** II II *** Water Heating not calculated . GENERAL INFORMATION HERS Verification.......... Not Required Conditioned Floor Area..... 1910 sf Building Type. ............. Single Family Detached Construction Type ......... Existing+Addition+AlteratiDn Vintage.Assumptions ....... Before 1978 Natural Gas at Site ....... Yes Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Building.Stories. 1 Weather -Data Type........... FullYear Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 15280 cf Slab -On -Grade Area......... 1316 sf Glazing;Percentage......... 28.6 % of floor area Average Glazing U -factor... 1.14 Btu/hr-sf-F Average Glazing SHGC....... 0.78 Average Ceiling Height..... 8 ft it .. .. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-lR Page 2 Project Title.......... GB Inland Properties Date..06/20/1-4 10:15:01 �. MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties I` BUILDING ZONE INFORMATION Floor: # of # of Cond- Thermo- Vent Vent Verified Area .Volume Dwell Peop- it- stat Height Area _Leakage or Zone Type (sf) • (cf) Units le ioned Type (ft)- (sf) Housewrap EXISTING - Existing . Residence 1763 14104 0.92 4.6 Yes Setback 2.0 Standard No ADD - New (Added) s Residence 147 1176 0.08 0.5 Yes Setback 2.0 Standard No I ATTIC AND ROOF DETAILS Frame R- R - Roof Roof Re- Emiss- Frame Spac- Value Value 'lent Mass Rise flect- ivity Depth ing Above Below area Vent Roof Type (lb/sqft) ance (in.) (in.) Deck Deck 3atio High EXISTING - Existing Asphalt Light .5:12 0.08 0.85 3.5 24 oc ,0,00 0.00 L/300 0.00 ADD - New (Added) Asphalt Light .5:12 0.08 0.85 3.5 24 oc 0.00 0.00 L/150 0.30 OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) "or R-val R-val Azm Tilt Reference Comments , EXISTING - Existing 1 Wall Wood 412 0.356 0 0 90 90 Yes 4.3.1 Al ExtWall ' 2 Wall Wood ;52 0.356 '0 0 45 90 Yes 4. 3. 1 Al ExtWall 3 Wall Wood .32 0.356 0 0 135 90 Yes 4.3.1 Al ExtWall 4 Wall Wood 241 0.356 0 0 180 90 Yes 4.3.1 Al ExtWall 6 Wall Wood 259 0.356 0 0 270 90 Yes 4.3.1 Al ExtWall . 7 Wall Wood lil2,0.356 0 0 225 90 Yes 4.3.1 Al ExtWall 8 Wall, Wood 34 0.356 0 0 315 90 Yes 4.3.1 Al. ExtWall 11 Wall Wood 149 0.356 '0 _ 0 0 90 Yes 4.3.1 Al ExtWall 13 Attic Wood 1763 0.049 19 0 n/a 0 Yes 4.2.1 A4 Attic 15 Floor Wood 207 0.097 0 01 n/a 0 No 4.4.1 Al Crawl 16 F1oorExt Wood 387 0.238 0 0 n/a 0 No 4.41.2 Al ExpFloor 17 Door Wood 14 0.500. 0 0 135. 90 Yes 4.5.1 A4 .Solid Wood 18 Door Wood 14 0.500 0 0 45 90 Yes 4.5.1 A4 Solid Wood 19 Door Wood 17 0.500 0 0 270 90'Yes 4.5.1 A4 Solid Wood EXISTING - Deleted 9 Wall Wood 150 0.356 0 0 270 90 Yes 4.3.1 Al ExtWall ADD - New (Added) CERTIFICATE` OF COMPLIANCE: RESIDENTIAL,,COMPUTER METHOD CF -1R Page 3 Project Title.......:.. GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments 5 Wall Wood 147 0.102 13 0 180 90 Yes 4.3.1 A3 ExtWall 10 Wall. Wood 62 0.102 13 0 270 90 Yes 4.3.1 A3 ExtWall 12 Wall Wood 127 0.102 13 0 0 90 Yes 4.3.1 A3 ExtWall 14 AtticRad Wood 147 0.049 19. 0 n/a 0 Yes 4.2.1 A4 Attic' ! PERIMETER LOSSES Appendix Length F2 Insul Solar JA4 Location/ Surface (ft) Factor R-val Gains Reference Comments EXISTING - Existing 20 S1abEdge 205 0.730 R-0/Oin No Non -Std Standard Slab Edge ADD - New.(Added) 21 S1abEdge 44 0.730 R-0/Oin No Non -Std Standard Slab Edge FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments EXISTING - Existing 1 Wind Front, (NE) 12.31.040 0.760 45 90 Standard F1/Wood Fixed ,2 Wind Front, (E) :9.4 1.280 0.800, 90 90 Standard F2/Metal Operable, 3 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F3/Wood Fixed 4 Door Front (SE) :6.0 0.990 0.740 135 90 Standard F4/Door Glazing 5 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F5/Wood Fixed 6 Door Front (NE) X6.0 0.990 0.740 45 90 Standard F6/Door Glazing 7 Wind Front (NE) 18.0 1.040 0.760 45 90 Standard F7/Wood Fixed 8 Wind Front (NE) 18.0 1.040 0.760 45 90 Standard F8/Wood Fixed 9 Wind Front (E) 12.2 1.280 0.800 90 90 Standard F9/Metal Operable 10 Wind Front (E) 10.0 1.280 0.800 90 90 Standard F10/Metal Operable 11 Wind Front (E) 12.3 1.280 0.800 90 90 Standard Fll/Metal Operable 12 Wind Left (S) 18.0 1.040 0.760 180 90 Standard L1/Wood Fixed 13 Wind Left (S) 18.0 1.040 0.760180 90 Standard L2/Wood Fixed 14 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L3/Metal Operable 15 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L4/Metal Operable 18 Door Back (W) 53.3 1.250 0.800 270 90 Standard B1/Metal Patio Door 19 Door Back (W) 53.3 1.250 0.800 270 90 Standard B2/Metal Patio Door 20 Wind Back (W) 18.0 1.040 0.760 270 90 Standard B3/Wood Fixed 21 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B4/Wood Fixed CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 Project Title.......... GB Inland Properties Date..06/20/.14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Prope.cties FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt, Type Location/Comm=nts 22 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B5/Wood Fixed 23 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B6/Wood Fixed" 24 Wind Back (SW) 18.0 1.040 0.760 225 90 Standard B7/Wood Fixed,( 25 Wind Back. (SW)' 18.0 1.040 0.760 225 .90 Standard B8/Wood Fixed 26 Door Back (SW) 40.0 1.250 0.800 225 90 Standard B9/Metal Patio Door 28 Door Right (N) 40.0 1.250 0.800 0 90 Standard R2/Metal Patio Door 29 Wind Right (N) 10.0 1.280 0.800 0 90 Standard R3/Metal Operable 30 Wind Right (N) 9.4 1.280 0.800 0 90 Standard R4/Metal Operable EXISTING - New (Added) 16 Wind Left (S) 10.7 1.280 0.800 180 90 Standard L5/Metal Operable EXISTING - Deleted 17 Wind Back (W) 12.3 1.280 0.800 270 90 Standard B1/Metal Operable ADD - New (Added) 27 Door Right (N) 20.0 0.530 0.650 0 90 Standard R1/French Door SLAB SURFACES Area Slab Type (sf) EXISTING - Existing ? Standard Slab 1169 ADD - New (Added) Standard Slab 147 HVAC SYSTEMS Verified Maximum Verified Total Number Verified Verified Cooling Verified Rated System of Minimum HighEff Refrig Charge Coil Fan Watt Cooling Type Systems,Efficiency EER or CID Airflow Draw Capacity EXISTING - Existing,, Furnace 1.84 0.780 AFUE n/a n/a n/a n/a n/a •ACPackage 1.84 13.00, SEER No' No No No No ADD - Existing Furnace .16 0.780 AFUE n/a n/a n/a n/a. n/a ACPackage .16 13.00 SEER No No No No No f ` r CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title.. . GB Inland Properties Date..06/20/14 10:15:01 HVAC SIZING Verified / Total Sensible Design Maximum Heating Cooling- Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) EXISTING - Existing Furnace 96599 n/a n/a n/a ACPackage n/a 92758 115113 n/a ADD- New (Added) Furnace 6142 n/a n/a n/a ACPackage n/a 3756 4662 n/a Total ,. 102741 96515 119775 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70.F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range........... .. 34 F, DUCT SYSTEMS Verified Verified Verified System Duct, Duct Duct Surface Buried Type Location R -value Leakage Area Ducts EXISTING - Existing Furnace Attic R-2.1 No No No ACPackage Attic R-2.1 No No No ADD - New (Added) Furnace Attic, R-2.1 No No No' ACPackage Attic R-2.1 No No No . FAN SYSTEMS Flow Power t System Type (cfm) (W/cfm)' EXISTING - Existing CERTIFICATE.OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page:6 Project Title.......:.. GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File_GBINLAND Wth-CTZ15808 I; User#-MP1680 User-Cal-Kool A/C & Heating Run-GB Inland Properties. SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans., ***' *** installed,to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a Radiant Barrier. Mechanical Fan System is not required to be installed for additions under 1000 square feet as noted in Exception•5•to Section 152(b). REMARKS CERTIFICATE OF.COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1P. Page 7 , Project Title.......... GB Inland Properties Date..06/20/=4 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run-GB Inland Prope_ties COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24; Parts 1 and 6 of the California Code of.Regulations, and the administrative regulat=ons to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or.OWNER DOCUMENTATION AUTHOR Name.... Kim Quon Name.... Debbie Miner Company. Kim Quon Architect Company. Cal-Kool A/C 6 Heating Address. 3266 Lincoln Ave. Address. 31600 Railroad Canyon Road Lake Elsinore, CA 92530 Canyon Lake, CA 92587 Phone... 951-201-1271 Phone... 951-244-4412 License. n/a - Signed.. Signed.. (date) (da--e) ENFORCEMENT AGENCY Name Title... Agency.. Phone... Signed.. (date) MANDATORY MEASURES SUMMARY: RESIDENTIAL MF -1R Page 8 Project Title.......:.. GB Inland Properties Date..06/20/14 10:15:01 Project Address........ 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8.l* Documentation Author... Debbie Miner ****** I Building Permit # Cal-Kool A/C 6 Heating 31600 Railroad Canyon Road I Plan Check / Date Canyon Lake, CA 92587 951-244-4412 Field Check/ Date Climate Zone.. .. 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8:1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties NOTE: Low-rise residential buildings subject to the Standards must comply with' all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1R, CF -IR -ADD, or CF -IR -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures.Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in -this summary. Submit all applicable sections of the MF -1R Form with plans. BUILDING ENVELOPE MEASURES: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. 118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of 118(i) when the installation of a Cool Roof is specified on therCF-1R Form *150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor. . *150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF-1R.Form. 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. 150(1): Water absorption rate for slab edge insulation material alone without, facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. FIREPLACES, DECORATIVE GAS APPLIANCES AND GAS LOG MEASURES: 150(e)lA: Masonry orifactory-built fireplaces have a closable metal or glass i MANDATORY MEASURES SUMMARY: RESIDENTIAL MF -1F: Page 9 Project Title.......:.. GB 'Inland Properties Date..06/20/14 10:15:01 I- MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties door covering the entire opening of the firebox. 150(e)1B: Masonry orifactory-built fireplaces have a combustion outs -de air intake, which is at'least six square inches lin area and is equipped with 'a with a readily accessible, operable, and tight -fitting damper and o= a combustion -air control device. 150(e)2: Continuous burning pilot lights.and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of =he building, are prohibited. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES: 110-113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. 113(c)5: Water heating recirculation loops serving multiple dwelling units and JHigh-Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection.' requirements of 113'(c)5. 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances. with an electrical supply voltage connection with pilot lights that consume -less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). 150(j)lA: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R=12 or greater. 150(j)1B: Unfired storage tanks, such as storage tanks or backup tar-ks for solar water-heating,system,.or other indirect hot water tanks have R-12 external insulation:or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. 150(j)2: First 5 feet of hot and cold water pipes closest -to water neater tank, non -recirculating systems, and entire length of recirculating sections of.hot water pipes are insulated per Standards Table.150-B. 150(j)2: Cooling system piping (suction, chilled water, or brine lir-es),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation�is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 150(j)3A: Insulationrfor chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water: -heating systems and/or collectors are certified by the Solar. Rating and Certification Corporation. DUCTS AND FANS MEASURES: 150(m)l: All air -distribution system ducts and plenums installed, are sealed MANDATORY MEASURES SUMMARY: RESIDENTIAL MF -1R Page,10 Project Title.......t.. GB Inland Properties Date..06/20/=4 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system.that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or,tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be.compressed to cause reductions in the cross-sectional area of the ducts. 150(m)2D: Joints and'seams of duct systems and their components shall not be sealed -with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fan;,systems have back draft or automatic dampers. 150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the, material. 150(m)10: Flexible ducts cannot have porous inner cores. 150(o): All dwellingiunits shall meet the requirements of ANSI/ASHRAM Standard 62.2-2007 Ventilation and Acceptable "Indoor Air Quality in Low -Rise Residential Buildings. Window"operation is not a permissible method of providing the Whole;Building Ventilation required in Section 4 of that - Standard. f POOL AND SPA HEATIN& SYSTEMS AND EQUIPMENT MEASURES: 114(a): Any pool or spa heating system shall be certified to have: a thermal. efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. 114(b).1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150.(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150(p). MANDATORY MEASURES SUMMARY: RESIDENTIAL MF -1R Page 11 Project Title.......:.. GB Inland Properties Date.:06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties RESIDENTIAL LIGHTING'MEASURES: 150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by 150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined as .specified by 130(d). 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. 150(k)5: Permanently:installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain aline -voltage socket or line -voltage lamp holder; OR shall. be rated to consume.no more than five watts of power as determined•by 130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150(k). 150(k)7: All switching devices and controls shall meet the requirements of 150(k)7. 150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts -for dwelling -units larger than 2,500 ft2 may be exempt from 'the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a'manual on occupant sensor, dimmer, energy management system (EMCS), or a.multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet; and utility rooms are high efficacy and controlled by a manual -on occupant sensor. 150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. 150(k)10: Permanently.ins_talled luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to, comply with the applicable requirements of 119. EXCEPTION 2: Permanently installed low.efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupant sensor. 150(k)ll: Permanently installed luminaires located in rooms or areas other ; than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be highefficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of 119, or by a manual -on occupant sensor that complies with the applicable requirements of 119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150(k)11: 150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other MANDATORY MEASURES SUMMARY: RESIDENTIAL MF -1R Page 12 Project Title............ GB Inland Properties Date..06/20/_4 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Prope=ties nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM -at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. 150(k)13: Luminaires providing outdoor lighting, including lighting -or private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires s=tall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the mo=ion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables th•a astronomical time clock; OR an energy management control system (EM --S) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor''luminaires used to comply with Exceptionl to 15D(k)13 may be controlled by a temporary override switch.which bypasses the motion sensing function provided that the motion sensor is automatically reactivat d within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming ?ool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. 150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to 130(d). 150(k)15: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131,-134, and 146. 150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of 119. HVAC SIZING HVAC Page 13 Project Title.......... GB Inland Properties Date..06/20/_4 10:15:01 Project Address......... 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8.1* Documentation Author... Debbie Miner ****** Building Permit # ' Cal-Kool A/C & Heating ' 31600 Railroad Canyon Road Plan Check / Date i Canyon Lake, CA 92587 951-244-4412 Field Check/ Date Climate Zone.........* 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties GENERAL INFORMATION Floor Area ...............!. 1910 sf Volume ..................... 15280 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location........... LA QUINTA Latitude .......... 33.8 degrees Winter Outside Design...... 26 F Winter Inside Design.:..... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes -Latent Load Fraction....... 0.24 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 43689 24396 Glazing Conduction and Solar..... 27252 36396 Infiltration ..................... 7028 4064 Internal Gain ..................... n/a 2768 Ducts... 24772 28891 Sensible Load.................... 102741 96515 Latent Load ...................... n/a 23260 Minimum Total Load 102741 119775 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also �be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING - HVAC Page 14, Project Title....t..... GB Inland Properties Date..06/20/=4 10:15:01," MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run-GB Inland Properties ' HEATING AND COOLING LOAD SUMMARY BY ZONE 5 ZONE-,'EXISTING' Floor Area.................... 1763 sf Volume ........................... 14104 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar ....... 40035 22885 Glazing Conduction and Solar..... 26786 35722 Infiltration....... ............ 6487 3751 Internal Gain...... n/a 2530 Ducts... .......................... 23291 27871 Sensible.Load.......... .......... 96599 92758, Latent Load.. ......... ........ n/a 22355• Minimum Zone Load 96599 115113 ZONE 'ADD/N' ' Floor Area........................ 147 sf Volume........................... 1176 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 3654 1511 Glazing Conduction and Solar..... 466 674 Infiltration.. ................. 541 313 Internal Gain....... . ......... n/a 238 .Ducts... 1481 1020 Sensible,Load..................... 6142 3756 Latent Load....... n/a 905 f Minimum Zone Load 6142 4662 { i CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -13 Page 1 Project Title:...`..:..:. GB Inland Properties. Date..06/20/14 10:15:01 Project Address...'..... 54925 Avenida Ramirez La Quinta, CA 92253 *v8.1* I I' Documentation Author.... Debbie Miner ******' I Building -Permit # Cal-Kool A/C & Heating 31600 Railroad Canyon Road I Plan Check / Date Canyon Lake, CA 92587 951-244-4412 I Field Check/ Date Climate Zone.. ........15 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C'& Heating Run -GB Inland Properties L i GENERAL INFORMATION HERS Verification.......... Not Required Conditioned Floor Area..... 1910 sf Building Type ............... Single Family Detached. Construction Type Existing+Addition+Alterat-on Vintage Assumptions Before 1978 Natural Gas at Site Yes Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units..." 1 Number of Building Stories. 1 Weather Data'Type.......... FullYear Floor Construction Type...:; Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 15280 cf <. Slab -On -Grade Area......... 1316 sf Glazing Percentage........'. 28.6 % of floor area Average.Glazing U -factor... 1.14 Btu/hr-sf-F Average "Glazing SHGC....... 0.78 Average Ceiling Height...... 8 ft II II MICROPAS8 ENERGY USE SUMMARY II II Energy Use Standard Proposed Compliance II Percent II II (kTDV/sf-yr) Design Design Margin Improvement II II Space Heating.....,...... 29.35 29.37 -0.02 -CA% II Space Cooling.......... 288.06 287.48 0.58 C.2% �I Ventilation Fans-.'...... 0.91 II 0.91 - 01.00 C.0% II Total 318.32 317.76 0.56 C.2% II II *** Building complies with Computer Performance *** II II *** Water Heating not calculated *** II GENERAL INFORMATION HERS Verification.......... Not Required Conditioned Floor Area..... 1910 sf Building Type ............... Single Family Detached. Construction Type Existing+Addition+Alterat-on Vintage Assumptions Before 1978 Natural Gas at Site Yes Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units..." 1 Number of Building Stories. 1 Weather Data'Type.......... FullYear Floor Construction Type...:; Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 15280 cf <. Slab -On -Grade Area......... 1316 sf Glazing Percentage........'. 28.6 % of floor area Average.Glazing U -factor... 1.14 Btu/hr-sf-F Average "Glazing SHGC....... 0.78 Average Ceiling Height...... 8 ft CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 Project Title.......... GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties BUILDING.ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf)" (cf) Units le ioned Type (ft) (sf) Housewrap. EXISTING - Existing Residence 1763 14104 0.92 4.6 Yes Setback 2.0 Standard No ADD - New (Added) Residence 147 1176 0.08 0.5 Yes Setback 2.0 Standard No. ATTIC AND ROOF DETAILS Frame R- R - Roof Roof Re- Emiss- Frame Spac- -Value Value Vent Mass Rise flect- ivity Depth ing Above Below Area Vent Roof Type (lb/sgft)` ance (in.) (in.) Deck Deck Ratio High EXISTING - Existing Asphalt Light .5:12 0.08. 0.85 .3.5 24 oc 0.00 0.00 :1/300 0.00 ADD - New (Added) Asphalt Light .5:12 0.08 0.85 3.5 24 oc 0.00 0.00 1/150 0.30 OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type •(sf) or R-val R-val Azm Tilt Reference Comments EXISTING - Existing 1 Wall Wood 412 0.356. 0 0 90 90 Yes 4.3.1 Al ExtWall 2 Wall Wood 52 0.356 0 0 45 90 Yes 4.3.1 Al ExtWall 3 Wall Wood 32 0.356 0 0 135 90 Yes 4.3.1 Al ExtWall 4 Wall Wood 241 0.356 0 0 180 90 Yes 4.3.1 Al ExtWall 6 Wall Wood 259 0.356 0 0 270 90 Yes 4.3.1 Al ExtWall 7 Wall Wood ;12 0.356 0 0 225 90 Yes 4.3.1 Al ExtWall 8 Wall Wood 34 '0.356 0 0 315 90 Yes 4.3.1 Al ExtWall 11 Wall Wood 149 0.356 0 0 0 90 Yes 4.3.1 Al ExtWall 13 Attic Wood 1763 0.049 19 0 n/a 0 Yes 4.2.1-A4 Attic 15 Floor Wood 207 0.097 0 0 n/a 0 No 4.4.1 Al Crawl 16 F1oorExt Wood 387 0.238 0 0 n/a 0 No 4.4.2 Al ExpFloor 17 Door Wood 14 0.500 0 0 135 90 Yes 4.5.1 A4 Solid Wood 18 Door Wood 14 0.500 0 0 45 90 Yes 4.5.1 A4 Solid Wood 19 Door Wood 17 0.500 0 0 270 90 Yes 4.5.1 A4 Solid Wood EXISTING - Deleted 9 Wall Wood 50 0.356 0 0 270 90 Yes 4.3.1 Al ExtWall ADD - New (Added) ~ CERTIFICATE OF COMPLIANCE RESIDENTIAL COMPUTER METHOD CF -1Z Page 3 Project Title.......... GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties Length F2 Insul Surface (ft) Factor R-val EXISTING - Existing Appendix Solar JA4 Location/ Gains Reference Comments 20 S1abEdge 205 0.730 R-0/Oin No Non -Std Standard Slab Edge ADD - New (Added) 21 S1abEdge 44 0.730 R-0/Oin No Non -Std Standard Slab Edge FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments EXISTING - Existing 1 Wind Front (NE) 12.3 1.040 0.760. 45 90 Standard F1/Wood Fixed 2 Wind Front (E) .9.4 1.280 0.800 90 90 Standard F2/Metal Operable 3 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F3/Wood Fixec 4 Door Front (SE) 6.0 0.990, 0.740 135 90 Standard F4/Door Glazing 5 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F5/Wood"Fixed 6 Door Front (NE) 6.0 0.990 0.740 45 90 Standard F6/Door Glazing 7 Wind Front (NE)- 18.0 1.040 0.760 45 90 Standard F7/Wood Fixed 8 Wind Front (NE) 18.0 1.040 0.760 45 90 Standard F8/Wood Fixed 9 Wind Front (E), 12.2 1.280 0.800 90 90 Standard F9/Metal Operable 10 Wind Front (E) 10.0 1.280 0.800 90 90 Standard F10/Metal Operable 11 Wind Front (E) 12.3 1.280 0.800 90 90 Standard Fll/Metal Operable 12 Wind Left (S) 18.0 1.040 0.760 180 90 Standard L1/Wood Fixed 13 Wind Left (S) 18.0 1.040 0.760 180 90 Standard L2/Wood Fixed 14 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L3/Metal Operable 15 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L4/Metal Operable 18 Door Back (W) 53.3 1.250 0.800.270 90 Standard B1/Metal Patio Door 19 -Door Back (W) 53.3 1.250 0.800 270 90 Standard B2/Metal Patio Door 20 Wind Back (W) 18.0 1.040 0.760 270 90 Standard B3/Wood Fixed 21 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B4/Wood Fixed OPAQUE SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments' 5 Wall Wood 147 0.102 13 0 180 90 Yes 4.3.1 A3 ExtWall 10 Wall Wood 62 0.102 13 0 270 90 Yes 4.3.1 A3 ExtKall 12 Wall Wood 127 0.102 13 0 0 90 Yes 4.3.1 A3 ExtWall 14 AtticRad. Wood 147. 0.049 19 0 n/a 0 Yes 4.2.1 A4 Attic PERIMETER LOSSES Length F2 Insul Surface (ft) Factor R-val EXISTING - Existing Appendix Solar JA4 Location/ Gains Reference Comments 20 S1abEdge 205 0.730 R-0/Oin No Non -Std Standard Slab Edge ADD - New (Added) 21 S1abEdge 44 0.730 R-0/Oin No Non -Std Standard Slab Edge FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments EXISTING - Existing 1 Wind Front (NE) 12.3 1.040 0.760. 45 90 Standard F1/Wood Fixed 2 Wind Front (E) .9.4 1.280 0.800 90 90 Standard F2/Metal Operable 3 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F3/Wood Fixec 4 Door Front (SE) 6.0 0.990, 0.740 135 90 Standard F4/Door Glazing 5 Wind Front (SE) 18.0 1.040 0.760 135 90 Standard F5/Wood"Fixed 6 Door Front (NE) 6.0 0.990 0.740 45 90 Standard F6/Door Glazing 7 Wind Front (NE)- 18.0 1.040 0.760 45 90 Standard F7/Wood Fixed 8 Wind Front (NE) 18.0 1.040 0.760 45 90 Standard F8/Wood Fixed 9 Wind Front (E), 12.2 1.280 0.800 90 90 Standard F9/Metal Operable 10 Wind Front (E) 10.0 1.280 0.800 90 90 Standard F10/Metal Operable 11 Wind Front (E) 12.3 1.280 0.800 90 90 Standard Fll/Metal Operable 12 Wind Left (S) 18.0 1.040 0.760 180 90 Standard L1/Wood Fixed 13 Wind Left (S) 18.0 1.040 0.760 180 90 Standard L2/Wood Fixed 14 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L3/Metal Operable 15 Wind Left (S) 12.3 1.280 0.800 180 90 Standard L4/Metal Operable 18 Door Back (W) 53.3 1.250 0.800.270 90 Standard B1/Metal Patio Door 19 -Door Back (W) 53.3 1.250 0.800 270 90 Standard B2/Metal Patio Door 20 Wind Back (W) 18.0 1.040 0.760 270 90 Standard B3/Wood Fixed 21 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B4/Wood Fixed CERTIFICARE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD' CF -13 Page 4 Project Title...:...... GB Inland Properties Date..06/20/:14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 I' User#-MP1680 User-Cal-Kool A/C & Heating, Run -GB Inland Prope_ties FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments 22 Wind Back (NW) 18.0 1.040 0.760 315 90 Standard B5/Wood Fixed. 23 Wind Back (NW), 18.0 1.040 0.760 315 90 Standard B6/Wood Fixed. 24 Wind Back (SW) 1.8.0 1.040 0.760 225 90 Standard B7/Wood Fixed. 25 Wind Back (SW) 18.0 1.040 0.760 225 90 Standard B8/Wood Fixed. 26 Door Back (SW) 40.0 1.250 0.800 225 90 Standard B9/Metal Patio Door 28 Door Right (N) 40.0 1.250 0.800 0 90 Standard R2/Metal Pati. Door 29 Wind Right,(N) 10.0 1.280 0.800 0 90 Standard R3/Metal Operable 30 Wind Right (N) 9.4 1.280 0.800 0 90 Standard R4/Metal Operable EXISTING - New (Added) 16 Wind Left (S) 10.7 1.280 0.800 180 90 Standard L5/Metal Operable EXISTING - Deleted 17 Wind Back (W) 12.3 1.280 0.800 270 90 Standard B1/Metal Operable ADD - New (Added) 27 Door Right (N) 20.0 0.530.0.650 0 90 Standard R1/French Door SLAB SURFACES area Slab Type (sf) EXISTING - Existing Standard Slab 1169 ADD - New (Added) Standard Slab 147 HVAC SYSTEMS Verif ied Maximum Verified Total Number Verified Verified Cooling Verifiad Rated System of Minimum HighEff Refrig Charge Coil Fan Watt Cooling Type Systems.+Efficiency EER or'CID Airflow Draw. Capacity EXISTING - Existing Furnace 1.84 0.780 AFUE n/a n/a n/a n/a n/a ACPackage' 1.84 13.00 SEER No No No No _ No ADD - Existing Furnace .16 0.780 AFUE n/a n/a n/a n/a n/a ACPackage .16 13.00 SEER No No' No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title.• ... '...... GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) .(Btu/hr) (Btu/hr) (Btu/hr) EXISTING - Existing Furnace 96599 n/a n/a n/a ACPackage n/a. 92758 115113 n/a ADD - New (Added) Furnace 6142 n/a n/a n/a ACPackage n/a 3756 4662 n/a Total 102741 96515 119775 n/a Sizing Location............ LA QUINTA Winter Outside Design...... 26 F Winter Inside Design....... 70 F Summer Outside Design...... 111 F Summer Inside Design....... 75 F Summer Range ............... 34 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R -value Leakage Area Ducts EXISTING - Existing Furnace Attic R-2.1 No No No ACPackage Attic R-2.1 No No No ADD - New (Added) Furnace Attic R-2.1 No No No ACPackage Attic R-2.1 No No No FAN SYSTEMS Flow Power System Type (cfm) (W/cfm) EXISTING - Existing Standard 52.13 .25 ADD - New (Added) Standard 5.07 .25 CERTIFICAME OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 MICROPAS8 v8.1 File-GBINLAND •Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and' *** *** verified during plan check and field inspection,. *** This building incorporates a Radiant Barrier. Mechanical Fan System is not required to be installed for additions under 1000 square feet as noted in Exception 5 to Section 152(b). REMARKS 1 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R. Page 7. Project Title.......... GB Inland Properties Date..06/20/14 10:15:01 �. MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications, needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... Kim Quon Name.... Debbie Miner Company. Kim Quon Architect Company. Cal-Kool A/C & Heating Address. 3266 Lincoln Ave. Address. 31600 Railroad Canyon Road. Lake Elsinore, CA 92530 Canyon Lake,'CA 9258r7 Phone... 951-201-1271 Phone... 951-244-4412 License. n/a Signed.. . Signed.. ed`�J , 4c C.L� (date) (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone.. Signed.. (date) MANDATORY MMASURES'SUMMARY: RESIDENTIAL MF -13, Page 8 Project Title.......... GB Inland Properties Date..06/20/14 10:15:01 Project Address........ 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8..l* Documentation Author... Debbie Miner ****** I Building -Permit # Cal-Kool A/C & Heating 31600 Railroad Canyon Road Plan Check / Date Canyon Lake, CA 92587 951-244-4412 Field Check/ Date Climate Zone........... 15 Compliance Method...... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Propezties NOTE: Low-rise.residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1R, CF -IR -ADD, or CF -IR -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1R Form with plans. BUILDING ENVELOPE MEASURES: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. 116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of 10-111(a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. 118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of 118(i) when .the installation of.a Cool"Roof is specified on the CF -1R Form. *150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's.installed design labeled R -Value. *150(c): Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according,to ASTM E1677-95(2000) when specified on the CF -1R Form. 150(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16: 150(1): Water absorption rate for slab edge insulation material alome without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. FIREPLACES, DECORATIVE GAS APPLIANCES AND GAS LOG'MEASURES: 150(e)lA: Masonry or;factory-built fireplaces have a closable metal or glass MANDATORY -MEASURES SUMMARY: RESIDENTIAL MF -1R Page 9 Project Title.......:.. GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties door covering the entire opening of the firebox. 150(e)1B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. 150(e)2: Continuous burning pilot lights and the use of indoor air fDr cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES: 110-113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. 113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve,.and recirculation loop connection requirements of 113(c)5. 115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the.setback requirements of Section 112(c). 150(j)lA: Storage gas water heaters rated with an Energy Factor no Greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 150(j)1B: Unfired storage tanks, such as storage tanks or backup tarts for solar water -heating system, or other indirect hot water tanks have R-12 external insulation:or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. 150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. 150(j)2: Cooling system piping (suction, chilled water,. or brine lir._es),and piping insulated between heating source and indirect hot water tank. shall be insulated to Table 150-B and Equation 150-A. 150(j)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 150(j)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water_heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. DUCTS AND FANS MEASURES: 150(m)1: All air -distribution system ducts and plenums installed, are sealed MANDATORY'MEASURES SUMMARY: RESIDENTIAL MF -1_2 Page 10 Project Title....'...:.. GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed. level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 150(m)l: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms.may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross -sectional -area of the ducts. 150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fan'systems have back draft or automatic dampers. 150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 150(m)9: Insulation shall be protected from damage, including that cue to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150(m)10: Flexible ducts cannot have porous inner cores. 150(o): All dwelling units shall meet the requirements of ANSI/ASHRFE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. POOL AND SPA HEATING SYSTEMS AND EQUIPMENT MEASURES: 114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the.Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. 114(b)l: Any pool or;spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. 114(b)3: Pools shall have directional inlets that adequately mix the pool water, and•a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of 150(p). MANDATORY_)lMASURES SUMMARY: RESIDENTIAL MF -1R Page 11 Project Title.......... GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C 6 Heating Run -GB Inland Properties RESIDENTIAL LIGHTING!MEASURES: 150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by 150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by 130(d). 150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. 150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only hdgh efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by 130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of 150(k). 150(k)7: All switching devices and controls shall meet the requirements of 150(k)7. 150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a.manual on occupant sensor, dimmer, energy management system (EMCS), or a.multi-scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet,: and utility rooms are high efficacy and contrclled by a manual -on occupant sensor. 150(k)9: Permanently' -installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. 150(k)10: Permanently. installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be.allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of 119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet'are not required to be controlled by a manual-cn occupant sensor. 150(k)ll: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be highsefficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of 119, or by a manual -on occupant sensor that complies with the applicable requirements of 119. EXCEPTION 2:'Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with 150(k)11. 150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other MANDATORY'1-1EASURES SUMMARY: RESIDENTIAL MF -1R Page 12 Project Title.......... GB Inland Properties Date..06/20/14 10:15:01. MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C & Heating Run -GB Inland Properties nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. 150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override.or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or.bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to 150(k)13 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California ' Electric Code need not be high.efficacy luminaires. 150(k)14: Internally illuminated address signs shall comply with Section 148;,• OR not contain a screw -base socket, and consume no more,than five watts of power as determinediaccording to 130(d). 150(k)15: Lighting for parking lots and carports with a total of for'.8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132; 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. 150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of 119. I- CERTIFICAfiE OF_'COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... GB Inland Properties Date..06/20/:14 10:15:01 Project,Address........ 54925 Avenida Ramirez ****** La Quinta, CA 92253 *v8.l* Documentation Author.... Debbie Miner ****** I_ Building Permit # Cal-Kool A/C & Heating 31600 Railroad Canyon Road Plan Cheek / Date Canyon Lake, CA 92587 951-244-4412 Field Ch•=_ck/ Date Climate Zone........... 15 Compliance Method....... MICROPAS8 v8.1 for 2008 CEC Standards (r03) MICROPAS8 v8.1 File-GBINLAND Wth-CTZ15S08 User#-MP1680 User-Cal-Kool A/C'& Heating Run -GB Inland Properties II MICROPAS8 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance Percent (kTDV/sf-yr) Design Design Margin 'Impr:>vement Space Heating.....'...... 29.35 29.37 -0.02 -0..1% Space Cooling.....,.... 288.06 287.48 0.58 0..2% I� Ventilation Fans..:.... 0.91 0.91 0.00 0.0% Total 318.32 .317.76 0.56 0.2% Building complies with Computer Performance *** n Water Heating not calculated *** II GENERAL INFORMATION HERS Verification.......... Not Required Conditioned Floor Area.:... 1910 sf Building Type.............. Single Family Detached Construction Type ......... Existing+Addition+Alterati.on Vintage Assumptions Before 1978 Natural'Gas at Site ....... Yes Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1. Number of Building Stories. 1 Weather Data Type.. ...... FullYear ' Floor Construction Type.... Slab On Grade Number of Building Zones... 2 Conditioned Volume......... 15280 cf Slab-On=Grade Area......... 1316 sf Glazing,Percentage.......... 28.6 % of floor area Average:Glazing U -factor... 1.14 Btu/hr-sf-F Average'Glazing SHGC....... 0.78 Average.Ceiling Height..... 8 ft , f CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -lit Page 2. Project Title......... GB Inland Properties Date..06/20/14 10:15:01 MICROPAS8 v8.1 File-GBINLAND Wth-CTZ1"5SO8 User#-MP1.680 User-Cal-Kool A/C & Heating Run -GB Inland Properties BUILDING ZONE INFORMATION Floor! # of # of Cond- Thermo - Area Volume Dwell Peop- it- stat Zone Type (sf) (cf) Units le ioned Type EXISTING - Existing Residence 1763 :14104 0.92 4.6 Yes Setback ADD - New (Added) Residence 147 1176 0.08 0.5 Yes Setback ATTIC AND ROOF DETAILS Vent Vent Verified Height Area Leakage or (ft) (sf) Housewrap 2.0 Standard No 2.0 Standard No Frame R- R Roof Roof Re Emiss- Frame Spac- Value Value Vent Mass Rise flect- ivity Depth ing Above Below Area Vent Roof Type (lb/sgft)' ance (in.) (in.) Deck Deck Ratio High EXISTING - Existing Asphalt Light. .5:12 0.08 0.85 3.5 24 oc 0.00 0.00 :/300 0.00 ADD - New (Added) Asphalt Light .5:12' 0.08 0.85 3.5 24 oc 0.00 0.00 _/150 0.30 OPAQUE SURFACES ADD - New (Added) i U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains JA4 Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comnents EXISTING - Existing 1 Wall Wood 412 0.356 0 0 90 90 Yes 4.3.1 Al ExtWall 2 Wall Wood .52 0.356 0 0 45' 90 Yes 4.3.1 Al ExtWall 3 Wall Wood 32 0.356 0 0 135 90 Yes 4.3.1 Al "ExtWall 4 Wall Wood 241 0.356 0 0 180 90 Yes 4.3.1 Al ExtWall 6 Wall Wood 259 0.356 0 0 270 90 Yes 4.3:1 Al ExtWall 7 Wall Wood '12 0.356 0 0 225 90 Yes 4.3.1 Al ExtWall. 8 Wall Wood •34 0.356 0 0 315 90 Yes 4.3.1 Al ExtWall 11 Wall Wood 149 0.356 0 0 0 90 Yes 4.3.1 Al ExtWall 13 Attic Wood 1763 0.049 19 0 n/a 0 Yes 4.2.1 A4 Attic 15 Floor Wood 207 0.097 0 0 n/a O No 4.4.1 Al Crawl 16 F1oorExt Wood 387 0.238 0 0 n/a 0 No 4.4.2 Al ExpFloor 17 Door Wood .14 0.500 0 0 135 90 Yes 4.5.1 A4 Solid Wood 18 Door Wood 14 0.500 0 0 45 90 Yes 4.5.1 A4 Solid Wood 19 Door Wood 17 0.500 0 0 270 90 Yes 4.5.1 A4 Solid Wood EXISTING - Deleted 9 Wall Wood 50 0.356 0 0 270 90 Yes 4.3.1 Al ExtTeall ADD - New (Added) i