Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-8298 (SFD)
`may 4 4 Q" BUILDING & SAFETY DEPARTMENT P.O. Box 1504 (760).777-7012 78-495 CALLE TAMPtCO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 BUILDING PERMIT Application Number. Property Address.. . . . . APN: Application description . . . Property Zoning . . . . . . . Application valuation . Owner LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111, STE C LA QUINTA, CA LA QUINTA 11 04-00008298" Date 3/22/05 79966 BARCELONA DR 609-380-999-47 -293234- DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 152664 Contractor LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, SUITE C LA QUINTA CA 92253 WCC: AON RISK SRVC WC: MWC11114500 11/01/05 CSLB: 728102 09/30/06 CCC: B Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE.EDITION 2001 CRC # BEDROOMS 5.00 FIRE SPRINKLERS NO GARAGE SQ FTG 425.00 .PATIO SQ 'FTG 53.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 2511.00 - ------------------------------------------_----------------------------------- Permit . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 825.00 Plan Check Fee 536.25 Issue Date . . . . Valuation . . . . 152664 Qty Unit Charge Per Extension BASE FEE 639.50 53.00 3.5000 THOU BLDG 100,001-500,000 185.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional'desc Permit Fee . . 111.39 Plan Check Fee 27.85 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2511.00 .0350 ELEC'NEW RES,- 1 OR 2 FAMILY 87.89 425.00 .0200 ELEC GARAGE.OR NON-RESIDENTIAL 8.50 N P.O. Box 1504 • VOCE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 70 Date: Applicant:ect or En i ee Applicant's Mailing Address: Ar hitect or Engineer's Address: CONTRAcrot� Lic. No.: L4 (�"_ BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm unde enalty of perjury that I am licensed under provisions of ChaWei (comm ncing with Section 7000) of Division 3 of the Business and Professionals ,eode, and my Lice a is ' full force and effect. % T ✓Licen�`sse lass `License No. ✓D ate J ` Contractor% )i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance V of the work for which this permit is issued. /t I have and will maintain workers' compensation insurance, as required by Section 3700.of the Labor Code, for the performance of the work for which this permit is i My workers' compensation insurance came✓ p= a r: /Carrier / Policy Number a/ V _ tit I cerci that, in the performance of the work for which this permit is issued, I sfrall no employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. /ate 1 � /) A licantV WARNIN : FAIL RE TO SECURE WORKERS' MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ, C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of Is county to enter upon the above-mentioned property for inspection purposes. DDte U IS Signature (Applicant or Ag Page 2 Application Number . . . . . 04-00008298 Date 3/22/05 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 46.00 Plan Check Fee 11.50 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH VENT FAN 6.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------=- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 170.25 Plan Check Fee 42.56 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 17.00 6.0000 EA PLB FIXTURE 102.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 47. PLAN 4YR, 2511 SF. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 53.63 DIF FIRE PROTECTION -RES 97.00 .X` Page 3 Application Number 04-00008298 Date - 3/22/05 ----------------------- Other Fees . . . ------------ . . . . . -------------------- GRADING PLAN CHECK ------ FEE -------------- .00 DIF LIBRARIES - RES 225.00 DIF• PARK -MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 15.26 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 1167.64 -------------------- .00 ----------- .00 1167.64 Plan Check Total 618.16 .00 .00 618.16 Other Fee Total 2473.89 ..00 .00 2473.89 Grand Total 4259.69 .00 .00 4259.69 SEP -23-2005 FRI 07:06 AM TEAM HEATING & A/C FAX N0, 9516943803 P. 02 HVAC INSTALLATION CERTIFICATE for Tested.Duct Leakage.& TXV Page 1 oft CF-6RSite Address: j 79-966 Barcelona Drive, La Quinta,_Ca_92263- Permit Number: Tract Number 29323 Plan #: 4Y Phase: 12 Lot Number: 47 Project: Esplanade An Installation certlticate is required to be posted at the building site or made avallble for all appropriate Inspections. Atter completion of tlnal Inspection, a copy must be provided to the Building Department (upon request) and the buUdlnc owner at occupancy, per Section 10-103(b). MVAC SYSTEMS: Heating Equipment Builder: Lennar Homes -4wV• ..ckl LIcnmr,u iwrr rvame -� Identicle I (SEER, etc,) I Location I Duct I Load- I Capacity Type and Model Number Systems (-CF-1 R) (attic, etc.) R -value (BTU I Hrl (BTU / Hrl Iwo��L�'!-3}iC IOf�T� ....-. _._.a..--. --.•y .,.-. �y�.r•,,�m „o.=., ..... v. 11 14 um -Aum tiquipmenr msraued, z) equivalent to or more efficient than that specified ' certificat f com 'ance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for re den ' ildi gs, an ) uipment that meets or exceeds the appropriate requirements for manufactured device the pli n e E nc lations of art 6 were applicable. 1 Z a Team Heating & Air, Inc igna ure, a e installing Subcontractor Name OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS DUCT LEAKAGE COMPLIANCE CRFn1T Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: System of Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of output BTU per hour) x (0,06) Measured Fan Flow x.06 Nuff Pressurization Test Resu s 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) TT 24 Compliance Credit was Taken for TXV m E-2-1 ofj Indicate the 'max "mum a owa le Duct Leakage and the calculation used: 0.7x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity In Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow X.06 D-0 Pressurization Test Resu 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) E2]T-24 Compliance Credit was Taken for TXV TXV wa: TXV wa: PAGE 1 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro ,I4 SEP -23-2005 FRI 07:06 AM TEAM HEATING & A/C FAX N0, 9516943803 P, 03 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R Site Address: 79-966 Barcelona Drive, La Quinta, Ca 92253 Permit Number: 0 Tract Number: 29323 Lot Number: 47 Project: Esplanade System © of Indicate the maximum aowe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate zone 6 through 15 0.5 x Floor Area x (0,06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uc Pressurization Test Results 100 x Test Leakage 1 Fan Flow = % Leakage Check Box for Pass or Fall (Pass = 6% or Less) T 24 Compliance Credit was Taken for TXV ys em F''�� of Indicate the m—aRlmum a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0,5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow Uuc Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) [PT -24 Com Iiance Credit was Taken for TXV ys em of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity In Nominal Tons) x (0,05) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow MET Pressurization Test Resu s 100 x Test Leakage / Fan Flow = % Leakage Check Sox for Pass or Fail (Pass = 6% or Less) 7-24 Compliance Credit was Taken for TXV ys em Q of r j Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate ,zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow u Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass o 6% or Less) OT -24 Compliance Credit was Taken for TXV X.06 x .06 X'06 X.06 TXV was TXV way Plan #: 4Y Phase: 12 Builder: Lennar Homes TXV was TXV wai I, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for mpli e c it_ ( builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees r s b on o c ify g that diagnostic testing and Installation meet the requirements for compliance credit)IJ Team Heating & Air, Inc e6ts Z gna ure, u a te installing Subc0ntractor (Co. ame Performed OR General Contractor (Co. Name) OR Owner COPY T0: Building Department HERS Provider (If applicable) Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro Damon ENERGY, C.A.. D E C Sammi PO. Box 621 Ph/Fek (760) 564-2044 Rancho Mirage, CA 92270 Cell: (760] 250-1852 Email: DESNRG RAOL.COM CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R TAPESTRY @ ESPLANADE PH 9 DATE TESTED 02-01-05 Project Title Date PARKWAY ESPLANADE NORTH LA QUINTA CA !LENNAR HOMES roLec'i Address Builder Name TONY PASCANITE 909-275-0204 PLAN 2 1 UNIT Builder Contact Telephone RICHARD KROWN 760-250-1852 HERS RateM-L Telephone #CCNRK613292#CCNRK613292 02-02-05 Certifying Signature Date Firm: DESERT ENERGY SERVICES LLC Street Address: P.O. BOX 621 Copies to: Builder, HERS Provider Plan Number GROUP 5 Sample Group Number LOT 56-9 Sample Lot Number HERS Provide'T: CHEERS City/State/Zip:; RANCHO MIRAGE, CA. 92270 HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested 0 Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify thatithe houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Duct Pressurization Test Results (CFM @ 25 Pa) Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Measured values Leakage Percentage ()00 x Test Leakage/Fan Flow) _ Check Box for Pass or Fail (Pass=6% or less) ❑ ❑ Pass Fail ❑ THFRMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ .Q w Certificate of insulation 1 Your home has been insulated with Certain Teed Fiberglass insulation products, which are designed for today's safety standards and tomorrads energy requirements. Fiberglass is inorganic and therefore permanently noncombustible, so it does not have to be treated with fire -retardant chemicals that will likely lose their effectiveness overtime. It has. not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will, it settle over time as may other insulation materials. This-also-certifiesthat insulation have -been- professionally -installed -in -this -home -to provide -the-- -- following thermal performance. Job Name: Lennar Homes, Inc. Tract: 29323 Plan# 2 Phase: 9 Lot No: 66 Job Address: SFR - 79403 Parkway Esplanade North, La Quinta, CA Ceiling Area: R -3a bl-own-in fiberglass insulation Garage Ceiling: Non -Access: With Living Above & Sloping Areas Exterior Walls R-13 batt insulation Overhangs: Access Attic: Between Floors: With Living Above Interior Walls: Subcontractor ..0 J Insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 92276 Signed: M r 1�? o rwnn Mike Dickerson, General Manager- Palm Springs Branch R -means resistance to heat flow. The higher the R -value, the greater the insulating power. Ask your buiilderfor the fact sheet on R -values. Keep this certificate with yourother valued papers. If you ever sell this home, this certificate. should be passed on to the buyer. • �1