Loading...
04-8111 (SFD);s Tldf 4 4 a" )4 E TAMPICO CALIFORNIA 92253 BUILDING PERMIT Property Address . . . APN: Application description Property Zoning . . Application valuation . Owner ------------------------ SHEA LA QUINTA C/O JEFF MCQUEEN 8800 N GAINEY CENTER 350 SCOTTSDALE AZ 85258 BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 04-00008111 Date 1/31/05 81182 BARREL CACTUS RD 764-270-999-33 -300233- DWELLING - SINGLE FAMILY DETACHED MEDIUM-HIGH DENSITY RES 150034 Contractor SHEA HOMES , . INC . 81260 AVENUE 62 LA QUINTA CA 92.253 (760) 777-6005 WCC: NTL UNION INS WC: 6436568 08/01/05 CSLB: 672285. 06/30/05 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 # BEDROOMS 3.00 FIRE SPRINKLERS NO' GARAGE SQ FTG 576.00. PATIO SQ FTG 177.00 NUMBER OF UNITS 10.00 1ST FLOOR SQUARE FOOTAGE 1688.00 --------------------------------------------------------- Permit . . . . . . ------------------ BUILDING PERMIT Additioftal desc Permit Fee 818.00 Plan Check Fee 531.70 Issue Date . . . . Valuation . . . . 150034 Qty Unit Charge Per Extension • BASE FEE 639.50 51.00 3.5000 THOU BLDG 1001001-500,000 178.50 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc . . Permit -Fee . . . . 64.00 Plan Check Fee 16.00 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 - 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 P.O. BOX 1504 • �� VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 04 49 11 ( Dole: I15;11��. Applicant: hi rigieer. Applicant's Mailing Address:—Architect or Engineer's Address. Lir,, No.:� t BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm and natty of perjury that I am licensed under provisions o 8pt�r ng with Section 7000) of Division 3 of the Business and Professionals gpde, and my L' ar in full force and effect. (/1 ,,--'License Vass ce se No v 4mnat.A:L Cmntrarto OWNER43UILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (__) I am exempt under Sec. , B.& P.C. for this reason ,,-�Date Owner_ WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this pegmit is issued. ha a andkIlla,'intain wo P compensation insurance, as requir by ! n 37 0 of the Labor Code, for the performance of the work for which this permit is s ued.ers' com sation insurance ca 'err li Feat Carrier Policy Number V _ I certify that, in the performance of the work for which permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Calif m, , and agree that, if hould become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall to with comply with those pr ion e pplicant WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta. its officers, agents and employees for any act or omission related to the work being PJrformed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if wo is t commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancel ion. I certify that have read this application and state that the above info rrect. I ree to comply with all city and County ordinances and state laws relating to building XII: and reby authorize representatives of this county t upon abov ned property for inspection purposes. r/ e ignature (Applicant or Agent): Page 2 Application Number . . . . . 04-00008111 Date 1/31/05 Qty Unit Charge Per Extension 1.00 6.5000 EA MECH VENT FAN 6.50 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 85.60 Plan Check Fee 21.40 Issue Date- Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 1688.00 .0350 ELEC NEW RES - 1 OR 2 -FAMILY 59.08 576.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 11.52 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 128.25 Plan Check Fee 32.06 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 10.00 6.0000 EA PL& FIXTURE 60.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT Plan 4520C 1688 SF with Box Bay @ Master (26sf) & 4' Ext Garage (88sf) . -------------------------- Other Fees . . . . . -------------------------------------------------- . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 w Page 3 Application Number.. . . . . . 04-00008111 Date 1/31/05 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 53.17 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE 00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 15.00 DIF STREET MAINT FAC -RES 15..00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged ---------- Paid Credited Due Permit Fee Total 1110.85 ------------------------------ .00 .00 1110.85 Plan Check Total 601.16 .00 .00 601.16 Other Fee Total 2473.17 .00 .00 2473.17 Grand Total 4185.18 .00 .00 4185.18 T j CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page CF -4R TRILOGY @ LA QUINTA- PH- 9A (Partial) 6-21-05 Project Title Date j c�81182 Barrel Cactus Rd., ' La Quinta, CA 92253 SHEA HOMES Proje Joed inor 760-535-2192 '$M 4910 Box Bay @ Mbr Buildeiffiam Henson (CCN #CC2004076) 7M -'ft ---1022 Platelumber HERS Raters p Certify n Sg ignature Firm: BCI Testing Street Address: PO Box 50575 Copies to: Builder, HERS Provider Telephone 6-21-05 Date Sample ,Group Number ..-,.33 (ph9A) Sample House Number HERS Provider: CALCERTS City/State/Zip: Phoenix, AZ 85076 HERS RATER COMTLIANCE STATEMENT The house was:l Tested ❑ Approved as part of sample testing, but was not tested As the HERS rater providing diagnostic testing and field verification, I'certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ® The installer has provided a copy of CF -6R (Installation Certificate. Distribution system is fully ducted.(i.e.; does not use building cavities as plenums or platform returns in lieu of ducts) Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfin/ton x number of tons enter calculated ' value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) _ Check Box for Pass or Fail (Pass=6% or less) ❑ Pas s' Fail O THERMOSTATIC EXPANSION VALVE (TXV) Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT 1. ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -1R and design on plan. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. Measured Fan Flow = ❑ ❑ Yes for both 1 and 2 is a Pass Pass Fail Compliance Forms August 2001 A-16 I JCM Inspections 39725 Garand Lane Suite F I Palm Desert, CA 92211 P E C T I O N S Phone: 760-345-5554 - Fax: 760-772-3895 INSPECTIONS 1w COMPRESSION STRENGTH TEST RESULTS Client: Shea La Quinta, LLC Date: 5/10/05 Project: Trilogy @ La Quinta - Shea Homes Project No: 02-1109 81-260 Avenue 62 La Quinta, CA 92274 Set ID Structure Age of Test Compression Strength JCM ID Location Date Cast Cylinder ID (days) (psi) Set A—Phase 9A - Lot # 3033- Slab on Grade 3-23-05 Concrete 273469,Entry Required psi: 4000 9396 7 3240 L5i \ ���Z �-� r��� �� 9397 28 4240 l 9398 28 4220 CERTIFIED: JC Inspections supplies the service of compression strength test results only. Per ASTMC39 • • Page 1 of 1 • INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 81-182 BARREL CACTUS, ;LOT 3033, PHASEr9A, LA QUINTA, CA CEILINGS: TYPE: BLOWTHICKNESS: R-38 MAUNFACTURER: Owens Corning WALLS. TYPE: BLOW MANUFACTURER: Certainteed THICKNESS: R-13 GENERAL CONTRACTOR: SHEA HOMES LICENSE# BY: TITLE: PARAGON CHMfD BUILDING PRODUCTS A MASCO Company LICENSE # 221517 BY TITLE: ACCOUNT REPRESENTIVE DATE: I V0EZ9VE09L L0:60 500Z/E0/90