09-0372 (AR)14- �
P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 09-00000372
Property Address: 81182 BARREL CACTUS RD
APN: 764-270-999-33 -300233-
Application description: ADDITION - RESIDENTIAL
Property Zoning: MEDIUM HIGH DENSITY RES
Application valuation: 24878
Applicant:
� •
Ti -ht 4 4 Q"
Architect or Engineer:
/
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
LICENSED CONTRACTOR'S DECLARATION
1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B Licen 667383
Date,6 I ISIM Contractor:
WNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.I.
Lender's Name:
Lender's Address:
LQPERMIT
Owner:
RICHARD FUSS
81182 BARREL CACTUS
LA QUINTA, CA 92253
Contractor:
FRENCH CONSTRUCTI
705 SUNNYSIDE AVEN
REDLANDS, CA 92373
(760)775-3618
Lic. No.: 667383
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
\ Date: 6/08/09
O
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 0028844-2007
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' c 'on provisions of Section
3700 of the Labor Code, I shall forthwith comply vy, ose provision .
Date 3.Applicant:
WARNING: FAILURE TO SECURE WORKERS' C MPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby sentatives
of this county to enter upon the above-mentioned property for inspection pu os€s.
Dater//S 0 Signature (Applicant or Agent)
Application Number . . . . . 09-00000372
------ Structure Information 300 SF GUESTHOUSE ADDTN.
-----
Other struct info
. . . . . CODE EDITION 2007
.## BEDROOMS
1.00
FLOOD ZONE NO
GARAGE SQ FTG
.00
PATIO SQ FTG
.00
1ST FLOOR SQUARE FOOTAGE
300.00
--------------------------------------------------------------------=-------
2ND FLOOR SQUARE FOOTAGE
.00
Permit . . .
. . BUILDING PERMIT
Additional desc
300 SF GUESTHOUSE ADDTN.
Permit Fee
252.00 Plan Check Fee
163.80
Issue Date . .
. . Valuation . . . .
24878
Expiration Date
11/18/09
Qty Unit
Charge Per
Extension.
BASE FEE
45.00
23.00
----------------------------------------------------------------------------
9.0000 THOU BLDG 2,001-25,000
207.00
Permit .
. . ELECT - ADD/ALT/REM
_ Additional desc
. .
Permit Fee . .
. . 25.50 Plan Check Fee
6.38
Issue Date . .
. . Valuation . . . .
0
Expiration Date
. . 11/18/09
Qty Unit
Charge Per
Extension
BASE FEE
15.00
300.00
----------------------------------------------------------------------------
..0350 ELEC NEW RES - 1 OR 2 FAMILY
10.50
Permit .
. . GRADING PERMIT
Additional desc
.
Permit Fee . .
. . 15.00 Plan Check Fee
..00
Issue Date . .
. . Valuation . . . .
0
Expiration Date
. . 11/18/09
Qty Unit
Charge Per
Extension
----------------------------------------------------------------------------
BASE FEE
15.00
Permit .
. . MECHANICAL
Additional desc
. .
Permit Fee . .
. . 39.50 Plan Check Fee
9.88
Issue Date . .
. . Valuation . . . .
0
Expiration Date
. . 11/18/09
LQPERMIT
Y' l
LQPERMIT
Application Number .
. . . . 09-00000372
Permit . . . . . .
MECHANICAL
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 9.0000
EA MECH FURNACE <=100K
9.00
1.00 9.0000
EA MECH B/C <=3HP/100K BTU
9.00
1.00 6.5000
----------------------------------------------------------------------------
EA MECH VENT FAN
6.50
Permit . . .
PLUMBING_
Additional desc . .
Permit Fee . . . .
58.50 Plan Check Fee
14.63
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
11/18/09
Qty Unit Charge
Per
Extension
BASE FEE
15.00
3.00 6.0000
EA PLB FIXTURE
18.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
----------------------------------------------------------------------------
Special Notes and Comments
Attached 300 SF GUESTHOUSE & 48 SF
BREEZEWAY ADDITION. R-3
OCC. TYPE V -B
CONSTRUCTION. 2007 CODES
----------------------------------------------------------------------------
Other Fees . . . . .
. . . . BLDG STDS ADMIN (SB1473)
1.00
ENERGY REVIEW FEE
16.38
STRONG MOTION (SMI) - RES
2.49
Fee summary Charged
Paid Credited
Due
---------------------------
Permit Fee Total
------------------------------
390.50 .00 .00
390.50
Plan Check Total
194.69 .00 .00
194.69
Other Fee Total
19.87 .00 .00
19.87
Grand Total
605.06 .00 .00
605.06
81-182 BARREL CACTUS
CASITA ADDITION [09-0372]
SCANNED
11/5/2009 - AO
[OFFICE DOCUMENTS]
Bin #
�A
City Of La Quinta
Building U Safety Division
Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #P.O.
A 3
Project Address: ARREL CAC'Tl/ j
Owner's Name: y USS
A. P. Number:
Address: 0' l Z EL eAC711.5
Legal Description:
City, ST, Zip:
Contrac( .,
Address: S a —3,H, 100 c f% mv
City, ST, : 9 Z ZO
Telephor.
State Lic. # : City Lic. #:
Telephone: — ?>'>:zs <>'z: >:: •:,
Project Deseription: % y
At e
Arch., Engr., Designer: R04 jpL F,D .e 2 Rbc
Address: "7 t{ • g� t/�� 1,V
City, ST, Zip: PALM t>ffsEn T
—hTelePo.
Hoe L/D %
State Lic. #: :t? >;>:->> :«? ;:>:>
Construction Type: Occupancy:
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: 1N4V lb L f R$ -,d )
Sq. Ft.:app
#Stories:
# Units:
Telephone # of Contact Person: 760 3 3.3
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Req'd
Rec'.d
TRACMG PERMIT FEES
Plan Sets
'l
Plan Check submitted 7�oZ 7 Item Amount
Structural Calcs.
Reviewed, ready for corrections Plan Check Deposit
Truss Calcs.
Called Contact Person Plan Check Balance.
Title 24 Calcs.
oC
Plans picked up Construction
Flood plain plan
Plans resubmitted % Q Mechanical
Grading plan
tad Review, ready for corrections su Electrical
Subcontactor List
Called Contact Person
Z Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
3d Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
-
APR 2 7 2009 1!1
1 Total Permit Fees t0r2, 046
5/7 IL,2t.(r�- 7 �voT-
_ZL f-----
Coachella Valley Unified School District
83-733 Avenue 55, Thermal, CA 92274
(760) 398-5909 — Fax (760) 398-1224
This Box For District Use Only
DEVELOPER FEES PAID
AREA:
AMOUNT
LEVEL ONE AMOUNT :
LEVEL TWO AMOUNT:
MITIGATION AMOUNT:
COMM/IND. AMOUNT:
DATE:
RECEIPT:
CHECK H:
INITIALS:
CERTIFICATE OF COMPLIANCE
(California Education Code 17620)
Project Name: Richard & Beverly Fuss Trust
Owner's Name: Richard & Beverly Fuss Trust
Project Address: 81-182 Barrel Caactus Rd., LaQuinta, CA
Project Description: Addition to SFD-attached guest house
APN: 764-410-006
Tract #:
Type of Development: Residential XX Commercial
Total Square Feet of Building Area: 300 sq. ft.
Certification of Applicant/Owners: The person signing certifies that the above
penalty of perjury and further represents that he/she is authorized to sign on bel
Dated: June 15, 2009 Signature:
Date: June 15, 2009
Phone No.
Lot #'s:
Industrial
and makes this statement under
**************************************4-*'********************************
SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN
ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE)
Education Code
17620
Number of Sq.Ft.
Amount per Sq.Ft.
Amount Collected
Gov. Code Project
65995 Approval
300 sq. ft.
$ 0.00
$ 0.00
Building Permit Application Completed: Yes/No
By: Carey M. Carlson, Asst. Supt., Support Services
Agreement Existing Not Subject to Fee
Prior to 1/1/87 Requirement
Note: Pursuant to AB -181, any room additions of 500 square
feet or less on existing dwelling_units are exempt from
developer fees. !Pursuant to AB -181, any mobile home being
relocated or replaced within our school district is exempt
from developer fees!
Certificate issued by: Laurie Howard, Secretary III Signature:Oi,{,L(,�J
NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES
Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the
project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these
Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to
advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other
requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this
time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of
Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up
to three (3) such extensions may be granted.
ivl V:c/mvdocs/devfccs/certificate ofcompliance farm tablesTO USE.doc 1/16/03 T
LL -,??L
a�
91 otir-
LL£ `ZR7
I�u %S:�/r% t/
v
� `� SS (T� vu�/j'd� 1 w
UU/15/ZU09 HN 10;54 FAX 760 777 6097 Trilogy at La Quinta
Trilogy at La Quinta Maintenance Association
April 13, 2009
Richard & Beverly Fuss
Property Address: 811.82 Barrel Cactus Road
Dear Mr. & Mrs. Fuss:
X001/001
COND><TONAL APPROVAL
We are pleased to inform you that your plans for addition of a casita to residence, received on 04/08/2009,
have been approved by the Design Review Committee per your submittal with the following condition(s): 7, 8,
9,11,15,16,17,18,19 and 23, Repair..landscapcand irrigation to.originul condition.
Please note: Any damages caused. by .contractor due to construction sball need to be repaired, all
irrigation and landscape shdH be 'restored to original condtion."
This approval does not constitute consent by the Association for the applicant to encroach, trespass, or build
on any property other than that of the applicant. This approval is related solely to Ihe: items reserved for
approval by die CC&R's in accordance with the Architectural Guidelines. The approval does not extend to the
quality of work done by your architect, or contractor, or to any structural engineering, soils engineering, or ,,ite
grading and drainage design. You are urged to obtain the set -vices of a state licensed professional for
consultation as needed.
'l'he Design Review Committee is composed of volunteers. As such, it does not review applications to ensure
compliance with building codes. or other local or state laws. Please be advised that this approval does not
relieve you from obtaining any necessary building pennits from the govenunental agencies involved to ensure
compliance with these codes. Any violations of these ordinances will be your responsibility to correct. Thank
you for your patience in this matter and for complying with the Association's policies and standards.
Sincerely,
For the DesigitiRcview Committee
Barry
Enclosures
Business Manager
Professionally Managed hl' Action Property Management, Inc.
60-750 '/Trilogy Parkway, La Quinta, CA 92253-7717
760-777-6059 800-400-12.94 760-777-6097 far
www. actionlrfc. cum
7
O L4
CO LnTn1
:�Jr
-u
10!
�,
-1�
'7
0)
-r—
.5(j
0.50%
00
Ln
119.5 '
.50 0.50 7."
-n
0)
-1117101
L.,L4
0)
�4
L4 0
�A
�40
0
OD
0
27.
46
U1
mgr r—
0
-n M
cn
L
(A
Ws.-
T ..;, >
0
6i Cal
Oi cj
'04
C�
Ct .. .......
...... .
-
Ulf
0) 0) Z
W �o
c
C)
0
R
15.5
.
0 -4 C) C,)
-4
-p- OD
C)
C) >
fa
a
--i
o
19'
'T
g
�Jl-
P,
,Tap
�4MO �4
--9- 9�1 —7.-
CP IQ
,c
cn
Li
/ 0.50%
L
1 0.50%
IM
--ro
46 .24 -'b.50% Y I
\1 16�1 01'
5 —0,-,
FL -;-GB
2.04% 0 --j 46
M
�
C)
-m-n a 0
J,
6 > - , * LW
-cp,
M. A c"r,
m �j
Q
-rN,
4� -N
ter
CD cn -:�
-P.
co
p. -40
01
7
TITLE 24 REPORT
Title 24 Report for:
FUSS'S RESIDENCE
f
LA QUINTA, CA
Project Designer:
OWNER
MR. & MRS. FUSS 8l - 1�2 �arresCaits
LA QUINTA, CA
Report Prepared By:
ADRIANA GIL
Adriana Gil
74-854 Velie Way Ste. #8
Palm Desert, CA 92260
L�' Err- n T TOTH
(l 2
II
API R e � 7 X009 I�1�
Job Number:
ADY618-0507
Date: u w
4/24/2009
CITY OF LA QUINTA
BUILDING & SAFETY Dom..
APPROVED
FOR CONSTRUCTION
)ATE 1 BY
37? -
11
72n r
aTlcfE-
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.4 by EnergySoft Job Number: ADY618-0507 User Number: 5553
k,
TABLE OF CONTENTS
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
1
2
3
6
8
EnergyPro 4.4 by EnergySoft Job Number: ADY618-0507 User Number: 5553
Certificate Of Compliance: Residential (Part 1 of 3) CF -1 R
_EU S_S' S_RESI DF ILC E
[XJ Single Family
❑ Addition
Total Conditioned Floor Area:
-4/24/2-0-09-
Project Title
Frame
❑ Multi Family
❑ Existing + Add/Alt
Date
-LP-Q.U_INIA
ft2
Building Front Orientation:
(S) 180 deg
Raised Floor Area:
Project Address
ft2
Fuel Type:
_R=0.0_
Building Permit #
A_ dr_iana_Gil
300
ft2
(760) 404-7917
-0..1.02.
Documentation Author
Average Ceiling Height:
9.0
Telephone
Plan Check/Date
_Ener_q�V/Rr_o
Avg. U: 0.34
Number of Dwelling Units:
-CA--AClimate_Zo.ne 1.5
_R=0...0_
Field Check/Date
Complilrice Method
Number of Stories:
1
Climate Zone
BUILDING ZONE INFORMATION
TDV
Standard
Proposed
Compliance
Wall_
(kBtu/sf-yr)
Design
Design
Margin
.H -VAC -Split -System
Space Heating
2.33
2.13
0.20
-n/a
Space Cooling
104.14
88.22
15.92
Fans
14.92
12.55
2.37
Domestic Hot Water
0.00
0.00
0.00
Pumps
0.00
0.00
0.00
Totals
121.40
102.90
18.50
Percent better than Standard:
15.2%
Building Type:
[XJ Single Family
❑ Addition
Total Conditioned Floor Area:
300
ft2
Frame
❑ Multi Family
❑ Existing + Add/Alt
Existing Floor Area:
n/a
ft2
Building Front Orientation:
(S) 180 deg
Raised Floor Area:
0
ft2
Fuel Type:
_R=0.0_
Natural Gas
Slab on Grade Area:
300
ft2
Fenestration:
-0..1.02.
-R_1.3_
Average Ceiling Height:
9.0
ft
Area:
90 ft2
Avg. U: 0.34
Number of Dwelling Units:
1.00
_R=0...0_
Ratio:
30.0% Avg. SHGC: 0.28
Number of Stories:
1
1.32_
BUILDING ZONE INFORMATION
_RA.3_
# of Thermostat
Vent
Zone Name
Wall_
Floor Area Volume
Units Zone Type Type
Hgt.
Area
.H -VAC -Split -System
9.0.9.0
300 -2,7.00
1..00_ Conditioned- -Setback-
2
-n/a
OPAQUE SURFACES
.01=A8
Insulation
Act.
_0.9=A3
Type
Frame
Area
U -Fac.
Cay.
Cont.
Azm.
Tilt
.Roof
Wood-
300_
_0.026_
_R_38_
_R=0.0_
-31.5_
1.8
Wall_
Wood_1_4.4_
-0..1.02.
-R_1.3_
_R=0..0_
1.8.0__9.0
Wall_
Wood_
1.3.5_
_0...0.7_4_
-R_1.9_
_R=0...0_
-2.7.0.9.0
Wall_
Wood-
1.32_
_0.1.02_
_RA.3_
_R=0.0_
0_
9.0
Wall_
Wood_
129_
_0..1.02.
_R_1.3_
_R=0...0.
9.0.9.0
Gains Condition
Y / N Status JA IV Reference Location / Comments
New
.01=A8
Whole
New
_0.9=A3
Whole
New
.0.9=A5
Whole
New
.0.9=A3
Whole
N.ew
.0.9=A3
Whole
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507 Paae:3 of 8 1
Certificate Of Compliance: Residential (Part 2 of 3) CF -1 R
FUSS'S RESIDENCE 4/24/2009
Project Title
Date
FENESTRATION SURFACES
1. Indicate source either from NFRC or Table 116A.
True Cond.
Location/
# Type
Area LI -Factor' SHGCZ
Azm. Tilt Stat. Glazing Type
Comments
J— WindowEron. t_(.S.)_
_3.6.0_ _0.34.0-NF_RC._0..28 -NERC 18.0_ _90_ N.ew _B.ET_T_ERB_U1LT_V_inyl_low E
Whole
2 Window Rear . (N_
48.0 0.340 NFRC 0_28 NFRC
0 90 New BETTER BUILT Vinyl low E
Whole
3 Window Right (E)
6.0 0.340 NFRC 0_28 NFRC
90 90 New BETTER BUILT Vinyl low E
Whole
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Slab Perimeter 61 None No Insulation 26-A1 New Whole
Right Fin
Dist. Len. Hqt.
Run Initiation Time: 04/24/09 10:39:14 Run Code: 1240594754
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507 Page:4 of 8
1. Indicate source either from NFRC or Table 116A.
2. Indicate source either from NFRC or Table 11613.
INTERIOR AND EXTERIOR SHADING
# Exterior Shade Type SHGC
Window
Hgt. Wd.
Len.
Overhang Left Fin
Hgt. LEA. REA. Dist. Len. Hgt.
1 Bug Screen 0.76
6.0 3.0
2.0
0.1 2.0 2.0
2 Bug Screen 0.76
8.0 6.0
2.0
0.1 2.0 2.0
3 Bug Screen 0.76
3.0 2.0
2.0
0.1 2.0 2.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R -Val. Location JA IV Reference Status Comments
Slab Perimeter 61 None No Insulation 26-A1 New Whole
Right Fin
Dist. Len. Hqt.
Run Initiation Time: 04/24/09 10:39:14 Run Code: 1240594754
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507 Page:4 of 8
Certificate Of Compliance: Residential (Part 3 of 3) CF -1 R
FUSS'S RESIDENCE 4/24/2009
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC Split System Split Heat Pump 7.20 HSPF Split Heat Pump 13.0 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R -Value Status Tested?
HVAC Split System Ductless / with Ductless n/a n/a New No
an
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated Tank Energy Tank Insul.
Water Heater # in Input Cap. Condition Factor Standby R -Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext.
Multi -Family Central Water Heating Details
Hot Water Pump
Control # HP
Hot Water Piping Length (ftL Add 1/2"
In Plenum Outside Buried Insulation
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality,
and building envelope sealing require installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Name:
Documentation Author
Name: ADRIANA GIL
Title/Firm: OWNER
Title/Firm:
Address: MR. & MRS. FUSS
Address:
LA QUINTA, CA
Telephone: ic. #:
(signature)
Enforcement Agency
Name:
Telephone:
U ry_/[ l-31-6 1
(d e) (signature)
Title/Firm:
Address:
Telephone:
(signature) (date)
Adriana Gil
74-854 Velie Way Ste. #8
Palm Desert, CA 92260
0
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507 Paae:5 of 8 1
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the
permit application documentation.
N/A
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑
❑X
❑
.§ 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation manufacturer's labeled R -Value:
❑
❑
❑
+§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not
❑
❑X
❑
apply to exterior mass walls).
❑
0
❑
�§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor.
❑
❑
❑
§ 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory -built fireplaces have:
❑
u
❑
a. closable metal or glass door covering the entire opening of the firebox
❑
❑X
❑
b. outside air intake with damper and control, flue damper and control
❑
❑X
❑
2. No continuous burning gas pilot lights allowed.
❑
❑X
❑
§ 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual.
❑
❑X
❑
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
❑
0
❑
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑
❑
❑
permeance rate no greater than 2.0 perm/inch.
§ 116: Insulation specified or installed meets insulation installation quality standards. Indicate type and include
❑
❑X
❑
CF -6R Form:
❑
❑
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
❑
❑X
❑
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain
infiltration
❑
❑X
❑
Coefficient (SHGC), and certification.
❑
❑
❑
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
❑
❑X
❑
Space Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission.
❑
u
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
❑
❑X
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
Q
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation
❑
Q
❑ '
having an installed thermal resistance of R-12 or greater.
2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external
❑
❑
❑
insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value.
3. The following piping is insulated according to Table 150 -AIB or Equation 150-A Insulation Thickness:
1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire
❑
❑
❑
length of recirculating sections of hot water pipes shall be insulated to Table 150B.
2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and
❑
❑
❑
indirect hot water tank shall be insulated to Table 150-B and Equation 150-A.
4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
❑
0
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑
❑
❑
entirely in conditioned space.
7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation.
❑
❑
❑
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507
Page:6 of 8
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lownse residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit
documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE -
applicable. N/A DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑x ❑
605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system
that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements
of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
tape shall be used.
2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ 0 ❑
sheet metal, duct board or Flexible duct shall not be used for conveying conditioned air. Building cavities and support
platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions
in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive
❑
❑X
❑
duct tapes unless such tape is used in combination with mastic and draw bands.
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑
4. Exhaust fan systems have back draft or automatic dampers.
❑
FX1
❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
❑
❑
❑
dampers.
❑
Lighting Measures
6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment
❑
0
❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water
and have an output frequency no less than 20 kHz.
retardant and provides shielding from solar radiation that can cause degradation of the material.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ Q
7. Flexible ducts cannot have porous inner cores.
❑
0
❑
§ 114: Pool and Spa Heating Systems and Equipment
❑ ❑x
❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
❑
❑
❑
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ Q
❑
2. System is installed with:
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
a. At least 36" of pipe between filter and heater for future solar heating.
❑ ❑
❑
b. Cover for outdoor pools or outdoor spas.
❑ ❑
❑
3. Pool system has directional inlets and a circulation pump time switch.
❑ ❑
❑
§ 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑
❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material meets specified criteria
❑ ❑
❑
Lighting Measures
§ 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ❑X
❑
150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric
and have an output frequency no less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
❑ Q
❑
luminaire has factory installed HID ballast.
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined
❑ ❑x
❑
in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires.
❑ Q
❑
OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d).
§ 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled
❑ ❑X
❑
by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑ ❑X
❑
certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals.
§ 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the
❑
❑
same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680
locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147.
❑ ❑
❑
Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146.
§ 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
❑ ❑
❑
dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d).
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507
Page:7 of 8
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
FUSS'S RESIDENCE 4/24/2009
SYSTEM NAME FLOOR AREA
HVAC Split System 300
Number of Systems
1
Heating System
Output per System
10,500
Total Output (Btuh)
10,500
Output (Btuh/sgft)
35.0
Cooling System
Output per System
12,200
Total Output (Btuh)
12,200
Total Output (Tons)
1.0
Total Output (Btuh/sgft)
40.7
Total Output (sgft/Ton)
295.1
Air System
CFM per System
0
Airflow (cfm)
0
Airflow (cfm/sgft)
0.00
Airflow (cfm/Ton)
0.0
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHI
26.0 of
Outside Air
0 cfm
70.0 of
COOLING SYSTEM PSYCH
111.0 / 77.6 of
Outside Air
0 cfm
76.0/61.7 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
Sensible
Latent
CFM
I Sensible
294
6,565
1,029
156
6,647
0
0
0
0
0
0
011
0
0
0
0
0
0
6,565 1,029
FUJITSU AOU12C1 10,288 48
Total Adjusted System Output 10,288 a8
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm
70.0 OF ® 110.0 OF
Heating Coil
K Return Air Ducts `i
76.0/61.7OF ■ 55.0/53.8OF
Cooling Coil
6,647
6,558
6,558
Jan 12 am
Supply Air Ducts
110.0 of
ROOMS
70.0 of
Supply Air Ducts
55.0 / 53.8 of
44.4% R.H. ROOMS
76.0 / 61.7 of
Return Air Ducts ( I
EnergyPro 4.4 by EnergySoft User Number: 5553 Job Number: ADY618-0507 Page:8 WW7771