Loading...
BPOL2015-0062el 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Ve COMMUNITY DEVELOPMENT.DEPARTMENT BUILDING PERMIT VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Application Number: BPOL2015-0062 Owner: Property Address: 57788 BARRISTO CIR RK KUBITSKI APN: 762500019 0 57 BARRISTO CIRCLE Application Description: KUBITSKI POOL, SPA, AND FIRE PIT INTA, CA 92253 Property Zoning: � 0 Q Application Valuation: $35,000.00 N c t_� a Applicant: o tractor: LINDLY'S POOLS OF CALIFORNIA I Q DLY'S POOLS OF CALIFORNIA 30755 DESERT PALM DRIVE 755 DESERT PALM DRIVE THOUSAND PALMS, CA 92276 r,_ OUSAND PALMS, CA 92276 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: C53 License No.: 833313 Date / �- Z 1 ' 1 � Contractor: JM OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of.sale.). I ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). L_J I am exempt under Sec. . B.&P.C. for this reason Date Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). . Lender's Na Lender's Address: (1760)343-0600. Llc. No.: 833313 Date: 3/27/2015 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the vork for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Secti n 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official.for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above. mentioned property for inspection purposes. Date: i ' Z- '� q, Signature (Applicant or Agent): PYIN FINANCIAL INFORMATION DESCRIPTION: ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS 101-0000-42401 0 $12.09 $0.00 PAID BY METHOD RECEIPT It CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE GAS SYSTEM, 1-4 OUTLETS PC 101-0000742600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forPLUMBING FEES: $36.26 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SWIMMING POOL/SPA 101-0000-42404 0 $181.29 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SWIMMING POOL/SPA PC 101-0000-42600 0 $98.62. $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for POOL / SPA: $279.91 $0.00 TOTALS:i0 Permit Details Enter Permit Number BPOL2015.0062 14 d= of 2 P >Q 0 O Find I Next hj - O Page 1 of 1 view Report �< Permit Details PERMIT NUMBER _ J S 'Q City of La Quinta BPOL2015-0062 nr Description: KUBITSKI POOL, SPA, AND FIRE PIT Type: POOL Subtype: Status: UNDER REVIEW Applied: 3/27/2015 SKH Approved: Parcel No: 762500019 Site Address: 57788 BARRISTO CIR LA QUINTA,CA 92253 Subdivision: TR 32225 Block: Lot: 19 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $35,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites:0 EMAIL Details: POOL, SPA, AND FIRE PIT. THIS PERMIT DOES NOT INCLUDE EQUIPMENT WALL OR BBQ. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. ALARMS AND BARRIERS REQUIRED TO BE INSTALLED AT PRE -PLASTER INSPECTION. 2013 CALIFORNIA BUILDING CODE. ADDITIONAL SITES CHRONOLOGY CONDITIONS CONTACTS NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT LINDLY'S POOLS OF CALIFORNIA 1 30755 DESERT PALM THOUSAND CA 92276 (818)307-2670 DRIVE PALMS CONTRACTOR LINDLY'S POOLS OF CALIFORNIA 1 30755 DESERT PALM THOUSAND CA 92276 (818)307-2670 DRIVE PALMS OWNER MARK KUBITSKI 57788 BARRISTO LA QUINTA CA 92253 (818)307-2670 CIRCLE FINANCIAL INFORMATION LTD CBY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT CHECK 0 METHOD PAID BY BY BSASS81473 FEE 1 101-0000-20306 1 0 $2.00 $0.00 111 Total Paid for BUILDING STANDARDS ADMINISTRATION $2,00 $0.00 BSA: GAS SYSTEM, 1-4 101-0000742401 0 $12.09 $0.00 OUTLETS GAS SYSTEM, 1-4 101-0000-02600 0 $24.17 $0.00 OUTLETS PC ED Total Paid for PLUMBING FEES: $36.26 $0.00 SWIMMING POOL/SPA 101-0000-02404 0 $181.29 $0.00 SWIMMING POOL/SPA 101-0000.42600 0 $98.62 $0.00 PC ID Total Paid for POOL/ SPA: $279.91 $0.00 TOTALS: $318.17 $0.00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES FINAL** BLD Printed: Friday, March 27, 2015 3:52:12 PM 1 of 2 CRI srs* — http://laquinta.crw.comltrakit9lOpenPDF.aspx?&report=/Documents/PERMITS/Permit De... 3/27/2015 SANTERRA OWNERS ASSOCIATION 57-519 Berristo Circle La Quinta; CA 92253 8,31-332-9100 March 23, 2015 City of La Quinta ®ear Sir]Madam: Please accept this letter as approval of the the swimming pool plans submitted by James Lndly of Lindly°s Pools of California, Inc. to_Santerra Owners Association for architectural review. This pool is to be looter! on Lot 19 our our development; The Board of Directors has reviewed these plans and accepts them as presented_ If you have any comments or questions in this regard, please do not hesitate to contact me. Thank you for your cooperation in this matter. Yours truly, Thomas R Stearns, President Board of Directors Santerra Owners Association ' Citjr of La QUinta Bwkmg ar Safety Meson K0 Box 1504,78-495 Caffe Tampfco 4.Quhlta, CA 92253 • (760) 777 7012 Building Permit Application and Tracking Sheet pwwt # Pmjeet Addrm: ✓�� — $ W>IrLu m . G 12 Owner's deme:. NI DAM- 1LUb 1TS K- 1 • A. P. Nnmbcr Address: i Legal Description: VD'r t Contraewr: L W O Vy P� LS b (A City. n' zip: u 1q, co, C12Z53 Telephone: PmjmDewription: 7rt— Address:3o�5's , �YLI". Jh� Da. City,ST,Tap: Af(�-- O ALAS CA "1 U�i I.C! 1vC,r�WI 00L SPS` • _i/,��' e `-• Telephorw.10')3- Opl�i r �1 ✓G�ul-,tv V-I�SL1IoE State Lie, 0: city Lie. #; Ib � , EW, Designer Address: City, ST, Zip: Telephone: Construction Type:. Occupancy. State Lie. #: Project type (circle one): New Add'n Alter Repair Demo Name of Coarse Penson: -Jo IF, �t�/(`Q L Sq. FL: # Stories: # Unitp: Telephone # of Comact Person: NO M2LASS-2, Estirowxd Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd Rtc'd TRACICYING PERMIT FEES - Plan Sets Pion Cheek submitted ffrm Amount Structural Cales. Reviewed, ready for corrections Pian Cbeck Deposit. . Tracts Cales. Called Contact Person Pour Check Sabanee- Title 24 Calcs. Plans picked up Canatractlon Flood plain plan Plans resubmitted Medrarilcal Giading plan Review, —dy for correctionsfrsue Electrical Subtoatoetor List Called Contact Person Plumbing Grant Deed Plans picked up S Dl.L H.O.A. Approval Plans resubmitted Gradin IN HOUSE-, ''' Review; ready fortorreetionsraSsae Devdoper Impact Fee Planning Approval. Called Contact Persoq A.LP.P. Pub. Wk. Appr Date of permit issue School Fees Total Permit Fees PROUDLY SERVING THE UNINCORPORATED AREAS OF RIVERSIDE COUNTY AND THE CITIES OF: BANNING BEAUMONT CALIMESA CANYON LAKE COACHELLA DESERT HOT SPRINGS EASTVALE INDIAN WELLS INDIO LAKE ELSINORE LA QUINTA MENIFEE MORENO VALLEY PALM DESERT PERRIS RANCHO MIRAGE' RUBIDOUx CSD SAN JACINTO TEMECULA WILDOMAR BOARD OF SUPERVISORS: BOB BUSTER DISTRICT 1 JOHN TAVAGLIONE DISTRICT 2 JEFF STONE DISTRICT 3 JOHN BENOIT DISTRICT 4 MARION ASHLEY DISTRICT 5 a . RIVERSIDE COUNTY FIRE DEPARTMENT IN COOPERATION WITH THE CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION 77-933 Las Montanas Rd., Ste. #201, Palm Desert, CA 922114131 • Phone (760) 863-8886 • Fax(760)863-7072 www.rvcfire.org February 21, 2014 Fire Sprinkler Systems Re: Residential Fire Sprinkler Plan Review LAQ-13-RS-093 Santerra Lot #19 57-788 Barristo Circle La Quinta, CA The sprinkler plans you submitted for the above referenced project have been reviewed by Riverside County Fire Department Planning & Engineering personnel and are approved with the following conditions: NOTE: Refer to sheet FP2 for "re -lined" change to plan. Permanently marked identification signs shall be attached to all control valves. A warning sign, with minimum '/ inch letters, shall be affixed adjacent to the main shutoff valve and shall state the following: WARNING: The water system for this home supplies fire sprinklers that require certain flows and pressures to fight a fire. Devices that restrict the flow or decrease the pressure or automatically shut off the water to the fire sprinkler system, such as water softeners, filtration systems, and automatic shut-off valves, shall not be added to this system without a review of the fire sprinkler system by a fire protections specialist. DO NOT remove this sign. The following inspections/tests are required to be witnessed by the Fire Department Planning Division staff: (a) Overhead Rough and Hydro static test: All piping shall be visible and pumped at normal operating pressure. (b) Final inspection. The Fire Department job card, approved plans and conditions letter' must be at the job site or NO inspection will be performed. Applicant/installer shall be responsible to contact the Fire Department to schedule inspection(s) a minimum of 72 hours prior to the requested inspection date. All questions regarding the meaning of these conditions should be referred to the Fire Department Planning & Engineering staff at (760) 863-8886. Applicant/installer shall be responsible to contact the Fire Department to sched le insp tion. Sincerely, Jaso Stubble Fire Safety Specialist CONSTRUCTION NOTES: POOL AREA: 355 SQ FT SPA AREA: 36 SQFT POOL PER,: 31 LN FT SPA PER.: 24 LN FT POOL DEPTH. 3'6" - S' TANNING SHELF TO BE -9" OF WATER (5, X 8) SPA TO BE RAISED 18" WITH A 5FT STACKED STONE SPILLOVER POOL BOND BEAM TO BE 25 LN FT +18" AND 11 LN FT +24" RAISED BOND BEAM TO HAVE (3) STAINLESS STEEL SHEER DESCENTS (1) 5FT AND (2) 2FT POOH. AND SPA WATER LINE TILE TO BE SELECTED FROM PRICE GROUPS 1-3 POOL AND SPA TO BE FINISHED IN PEBBLE COLOR: MIDNIGHT BLUE FIRE PIT TO BE RAISED 18", OUTSIDE FINISH PERIMETER TO BE IN TILE TO MATCH POOL WATERLINE. WITH DEDICATED GAS LINE, GAS VALVE AND KEY. FIRE GLASS. POOL DECK TO BE IN PAVERS TO MATCH EXISTING IN COLOR AND PATTERN WITH 12" X 12" POOL AND SPA COPING. POOL EQUIPMENT (PEEN -AIR SYSTEMS): (1) PENT -AIR VARIABLE SPEED PUMP (1) 424 SO FT CLEAN AND CLEAR FILTER (1) 3HP WHISPER FLOW PUMP. -SHEER DESCENTS (1) 400WATT POOL LIGHT (1) 100WATT SPA LIGHT (1) 400K BTU MASTER TEMP HEATER 'IIj IG40 EASY TORCH SALT SYSTEM --WIRELESS LANDSCAPE: A ... 5GAL SHRUBS B---15 GAL SHRUBS C--PALM TREES 1OFT TALL D---PALM TREES 8FT TALL E---PALM TRESS 6FT TALL F-SOD PLANTER BED FILLER TO BE IN D-G. ��ill�ll�lll rfL PROJECT ## : 2054 DRAWN BY: JO E GONZAL.EZ PROJECT NAME: MARK KU BIT KI 57-788 BARRITO ROAD LA QUINTA CA 32253 AvOl DATE: MARCH 11, 2015