Loading...
BSOL2015-011278-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Td4t 4 4a Qu&roj COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number: BSOL2015-0112 Property Address: 80960 BELLERIVE APN: 775350004 Application Description: GLEASON / 8.4kW PV SYSTEM - (28) 30OW PANELS/(2) INVERTER Property Zoning: Application Valuation: $33,000.00 Applicant: HEGGE ELECTRICAL CONTRACTORS I 83852 AVE 45 INDIO, CA 92201 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: CIO --L CIO--LLicense No.: 748171 Date , Contractor OWNER -BUILDER DEATION I hereby affirm under penalty of perjury that I an)/exempt from the Contractor's State License law for the following reason (Sec. 7031.6, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the ' Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ( ) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Owner: DAVID GLEESON 80960 BELLERIVE LA QUINTA, CA 92253 Contractor: HEGGE ELECTRICAL CO 83852 AVE 45 INDIO, CA 92201 (760)775-4855 Llc. No.: 748171 Date: 8/18/2015 D o cz M D 5I do ' D I C.71 I O WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the wo or which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: _ Policy Number: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall ith comply with hoose p visions. Date• b Applicant: ' WARNING: FAILURE TO SECURE WORKERS' COM PENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TQCRIMINAL ENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application., the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above• mentioned pr perty for inspection purposes. Date: Signature (Applicant or Agent): DESCRIPTION. FINANCIAL INFORMATION ACCOUNT' CITY AMOUNT PAID PAID DATE: BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 8/18/15 PAID BY METHOD RECEIPT # CHECK # CLTD BY HEGGE ELECTRICAL CONTRACTORS I CHECK R8564 30527 SKH Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $2.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $24.17 8/18/15 PAID BY!. METHO0 ` . RECEIPT # CHECK # CLTD BY HEGGE ELECTRICAL CONTRACTORS I CHECK R8564 30527 SKH DESCRIPTION ACCOUNT CITY. AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $24.17 8/18/15 PAID BY METHOD RECEIPT # .CHECK # CLTD BY HEGGE ELECTRICAL CONTRACTORS I CHECK R8564 30527 SKH Total Paid forELECTRICAL: $48.34 $48.34 DESCRIPTION ACCOUNT QTY AMOUNT. PAID - PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $91.85 8/18/15 PAID BY . . ' METHOD - RECEIPT # CHECK # CLTD BY HEGGE ELECTRICAL CONTRACTORS I CHECK R8564 30527 SKH Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: Description: GLEASON / 8.4kW PV SYSTEM - (28) 300W PANELS/(2) INVERTER ADDITIONAL Type: SOLAR Subtype: Status: APPROVED Applied: 7/22/2015 PJU, Approved: 8/14/2015 LUR Parcel No: 775350004 Site Address: 80960 BELLERIVE LA QUINTA,CA 92253 Subdivision: TR 28961 Block: Lot: 4 Issued: Lot Scl Ft: 0 Building Scl Ft: 0 Zoning: Finaled: Valuation: $33,000.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 7/22/2015 Details: 8.4kW SOLAR ARRAY- (28) 300W RENESOLA PANELS W/ (2) SUNNY BOY 4000TL-US INVERTERS [504SF] 2013 CALIFORNIA ELECTRICAL CODE. Applied to Approved Printed: Tuesday, August 18, 2015 4:31:01 PM 1 of 3 SYSTEMS ADDITIONAL CHIRdINIOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES PLAN CHECK PICKED UP STEPHANIE KHATAMI 8/3/2015 8/3/2015 PLAN CHECK SUBMITTAL PHILIP JUAREZ 7/22/2015 7/22/2015 PLAN CHECK SUBMITTAL RECIEVED FROM JIM HEGGE 760250 - RECEIVED 0144 PLAN CHECK SUBMITTAL STEPHANIE KHATAMI 8/12/2015 8/12/2015 RECEIVED SPOKE WITH CONTRACTOR REGARDING ERRONEOUS AND UNCLEAR COMMENTS FROM THE FIRST REVIEW PLAN, TELEPHONE CALL AJ ORTEGA 8/11/2015 8/11/2015 EXPLAINED I WOULD OVERSEE FURTHER PLAN CHECKS AND . THAT SPECIFIC ITEMS DO NEED TO BE SHOWN ON THE PLAN FOR EXPEDITED REVIEW. TELEPHONE CALL LUIS URIBE 7/31/2015 7/31/2015 CONTACTED JIM. 1ST REVIEW IS COMPLETE AND READY TO BE PICKED UP FOR CORRECTIONS. TELEPHONE CALL LUIS URIBE 8/14/2015 8/14/2015 SPOKE WITH JIM HEGGE LET HIM KNOW PERMIT WAS APPROVER AND READY TO ISSUE. Printed: Tuesday, August 18, 2015 4:31:01 PM 1 of 3 SYSTEMS INSPECTIONS FINANCIAL CONDITIONS CONTACTS SOLAR FINAL'"* BLD ---------- NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT HEGGE ELECTRICAL CONTRACTORS I 83852 AVE 45 INDIO CA 92201 (818)605-1515 CONTRACTOR HEGGE ELECTRICAL CONTRACTORS 1 83852 AVE 45 INDIO CA 92201 (818)605-1515 OWNER DAVID GLEESON 80960 BELLERIVE LA QUINTA CA 92253 (818)605-1515 INSPECTIONS FINANCIAL INFORMATION SOLAR FINAL'"* BLD CLTD DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $2.00 8/18/15 R8564 30527 CHECK HEGGE ELECTRICAL SKH CONTRACTORS Total Paid forBUILDING STANDARDS ADMINISTRATION $2.00 $2.00 BSA: PV SYSTEM -ARRAY, 101-0000-42403 0 $24.17 $24.17 8/18/15 R8564 30527 CHECK HEGGE ELECTRICAL SKH FIRST 20 CONTRACTORS I PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $24.17 8/18/15 R8564 30527 CHECK HEGGE ELECTRICAL SKH FIRST 20 PC CONTRACTORS I Total Paid for ELECTRICAL: $48.34 $48.34 PERMIT ISSUANCE 101-0000-424040 $91.85 $91.85 8/18/15 R8564 30527 CHECK HEGGE ELECTRICAL SKH CONTRACTORS I Total Paid for PERMIT ISSUANCE: $91.85 $91.85 TOTALS: $142.19 $142.19 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS NOTES SOLAR FINAL'"* BLD Printed: Tuesday, August 18, 2015 4:31:01 PM. 2 of 3 sysrerns Printed: Tuesday, August 18, 2015 4:31:01 PIM 3 of 3 �Jw' �L.I l.� SYS7EMS RETURNED REVIEWS STATUS REMARKS REVIEW TYPE REVIEWER SENT DATE DUE DATE NOTES DATE NON-STRUCTURAL - LUIS URIBE 7/22/2015 7/29/2015 7/31/2015 REVISIONS REQUIRED SEE ATTACHED CORRECTIONS LIST 1 WK NON-STRUCTURAL - LUIS URIBE 8/12/2015 8/19/2015 8/14/2015 APPROVED 1 WK Printed: Tuesday, August 18, 2015 4:31:01 PIM 3 of 3 �Jw' �L.I l.� SYS7EMS Jim Hegge From: John Wiles Sent: Tuesday, August 11, 2015 9:35 AM To: Subject: Re: Inverter output circuit- overcurrent protection sizing Jim The conductors from the inverter to the backfed breaker for each inverter are sized at 125% of the rated inverter current. In your case, that would be 1.25 x 4000/240 = 1.25 x 16.7 = 20.8 amps and a 25 amp breaker would be required for each inverter The 120% rule is based on the main breaker on the panel and the busbar rating. With the 225 amp bus your 120% gives 270 amps for a total of the main breaker and the two 25 amp PV breakers which total 50 plus the main. If you have a 200 amp main breaker then you are OK because 270> 200 + 50. If you have a 225 amp main, you are not OK because 270 < 225 + 50 =275. Might look at putting in a 200 amp main breaker if the main is interchangeable and your chapter 2 load calculations will allow a 200 amp service. If you can get an alternate methods and material waiver for the 2014 Code from the local AHJ, you use the 20.8 amps in the calculation and 270> 225 +2 x 20.8 = 226.6 and all is OK. John John C. Wiles, Senior Research Engineer Southwest Technology Development Institute, New Mexico State University 575-646-6105 httti://www.nmsu. edu/—tdi/Photovoltaics/Codes-Stds/Codes-Stds.html 3705 Research Drive Box 30001/MSC 3 SOLAR Las Cruces, NM 88003-8001 On Aug 10, 2015, at 7:38 PM, wrote: I thought I found my solution in705.12d2 exception except for the code year. I suppose I could change the main to a 200 & make it work Sent from my iPhone On Aug 10, 2015, at 5:41 PM, John Wiles < 'wrote: Jim: HEGGE ELECTRICAL CONTRACTORS, fNC. CA LIC. # 748171 What Code are you on? 2014 or 2011? JIM HEGGE ���� Signa e 7,10-77f i6f �'�"Title 1 John John C. ,Wiles, Senior Research Engineer Southwest Technology Development Institute, New Mexico State University 575-646-6105 htt://vAm.mnsu.edu/—tdi/Photovoltaics/Codes-Stds/Codes-Stds.html 3705 Research Drive Box 30001/MSC 3 SOLAR Las Cruces, NM 88003-8001 On Aug 10, 2015, at 4:58 PM, Jim Hegge < wrote: Mr. Wiles, I'm getting lost determining if I am over sizing a PV Solar system. I have 2 4,000 watt inverters.to a 225 Amp 240v service. 4000/240=16.66 continuous output amps per 690.8(A)(3),can I breaker this at 20 amps, or do I need to add 125% & breaker at 25? 225 amps x 120%=270 amps max feed,l can add 45 amps. Is the breaker size that matters or the continuous output that has to meet the 20% rule? Thank You! Jim Hegge HEGGE ELECTRICAL CONTRACTORS, INC. CA LIC. # 748171 JIM HEDGE Signature 76c7� 77� �g f�T�tle 1, Inte-tek Certified Innovative Powerful Flexible • UL 1741 and 1699B compliant • Secure Power Su Integrated AFCI meets the re quire- Supply provides • 97.6% maximum efficiency• Two MPP trackers provide q daytime power during grid outages • Wide input voltage range ments of NEC 2011 690.11 numerous design options • Shade management with OptiTrac • Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 380OTL-US /4000TL-US / 5000TL-US / 6000TL-US / 7000TL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US/7000TL-US/7700TL-US represents the next step in performance for UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracT"" Global Peak mitigate the effect of shade and ��{{��,�,,,��.,,, jp�� tt'POt%N The G9 Supply Feature provides daytime power in the event d #F17rL1SVh� t r r o features make the Sunny Boy TL -US series the first choice t° tg� 9• gOf m exi a estgn an tr7hovaTiJe MA aQ g��t �essionals. 9tia rM POO Signature _ L=- 76J- 77S = Sl��r—rifle JJ! Technical data Input (DC) Max. usable DC power (@ cos N - 1) Max. DC voltage Rated MPPT voltage range MPPT operating voltage range Min. DC voltage / start voltage Max. operating input current / per MPP tracker Number of MPP trackers / strings per MPP tracker Output (AC) AC nominal power Max. AC apparent power Nominal AC voltage/ adjustable AC voltage range AC grid frequency, range Max. output current Power factor (cos W) Output phases / line connections Harmonics Efficiency Max. efficiency CEC efficiency Protection devices DC disconnection device DC reverse -polarity protection Ground fault monitoring / Grid monitoring AC short circuit protection All -pole sensitive residual current monitoring unit Arc fault circuit interrupter (AFCI) compliant to UL 16998 Protection class / overvoltage category General data Dimensions (W / H / D) in mm (in) DC Disconnect dimensions (W / H / D) in mm (in) Packing dimensions (W / H / D) in mm (in) DC Disconnect packing dimensions (W / H / D) in mm (in) Weight / DC Disconnect weight Packing weight / DC Disconnect packing weight Operating temperature range Noise emission (typical). Internal consumption at night Topology Cooling Electronics protection rating Features Secure Power Supply Display: graphic Interfaces: RS485 / Speedwire/Webconnect Warranty: 10 / 15 / 20 years Certificates and permits (more available on request) NOTE: US inverters ship with gray lids Type designation HEGGE ELECTRICAL CONTRACTORS, INC. CA LIC. # 748171 JIM HEGGE S Signature 766 - 7 -75--- Slf1s� Tide Sunny Boy 3000TL-US 208 V AC 240 V AC 3200 W 600 V 175 - 480 V 125 - 500 V 125V/ 150V IBA/15A 3000 W 3000 VA 208 V / • 240V/ • 1 B3 - 229V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz 15A 1 1/2 <4% 97.2% 97.6% 96.5% 96.5% Sunny Boy 380OTL-US 208 V AC 240 V AC 4200 W 600 V 175 - 480 V 125 - 500 V 125V/ 150V 24A/15A 2/2 3330 W 3840 W 3330 VA 3840 VA 208 V/ • 240 V / • 183 - 229V' 211 - 264 V 60 Hz / 59.3 - 60.5 Hz 16A 1 1/2 <4% Sunny Boy 4000TL-US 208 V AC 240 V AC 4200 W 600 V 175 - 480 V 125 - 500 V 125 V / 150 V 24A/15A 4000 W 4000 VA 208 V/ • 240 V / • 183 - 229V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz 20A 1 1/2 . <4% 97.2% 97.5% 97.2% 97.5% 96.5% 97.0% 96.5% 97.0% SB 3000TL-US-22 SB 3800TL-US-22 SB 4000TL-US-22 3 490/519/185 (19.3/20.5/7.3) 187/297/ 190 (7.4/ 11.7/7.5) 617/597/266 (24.3/23.5/10.5) 370 / 240 / 280 (14.6 / 9.4 / 11.0) 24 kg (53 Ib) / 3.5 kg (8 Ib) 27 kg (60 Ib) / 3.5 kg (8 Ib) -40°C...+60°C (-40°F...+140°F) 5 25 dB(A) < 25 dB(A) < 25 dB(A) <1W < I W <1W Tronsformedess Transformerless Transformerless Convection Convection Convection NEMA 3R NEMA 3R NEMA 3R 0/0 0/0 0/0 0/0/0 0/0/0 0/0/0 UL 1741, UL 1998, UL 16998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 SB 3000TL-US-22 SB 3800TL-US-22 SB 4000TL-US-22 3 .......................................................................... . .................... Efficiency curve SUNNY BOY SOOOTL-US-22 240Vac>........................... :.................... ... ........................................... : 98 2/2 Speedwim/Webconnea RS485 interface interf- DM.AB5CB-US-10 96 i . ,. ...................................... 163 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz Fan kit for 7US-22 00) 22A 25A 29.2A 32A 4000/sooOnusn 1 1 1 FANKIT02.10 1/2 1/2 1/2 94 Data at nominal conditions 97.2% 97.6% Sunny Boy 7000TL-US Sunny Boy 770OTL-US 208 V AC 240 V AC 208 V AC 240 V AC 7300 W 8000 W 600 V 600 V 245 - 480V 92 125 - 500 V 125 - 500 V 125V/ 150V 125 V/ 150V 30A/ 18A 30 A/ 18A I i Iv Signature r1fle 90_._.- 490/519/185 (19.3/20.5'/7.3) a 187/297/190 (7.4/11.7/7.5) 88 370/240/280 (14.6/9.4/11.0) .... Em IV„ -175 V1 24 kg (53 Ib) / 3.5 k8 18 Ib) - E" IV. - 400 VI vs neo < 29 dB(A) < 29 dB(A) < 29 cIB(A) < 29 dB(A) (V„ - 480 V) <1W <1W <1W Transformerless Transformerless Transformerless Tronsformedess Convection 0 0.2 0.4 0.6 0.8 1.0 Output power / Rated power Sunny Boy 5000TL-US 208 V AC 240 V AC 5300 W 600 V 175 - 480 V 125 - 500 V 125V/ 150V 30A/15A Sunny Boy 6000TL-US 208 V AC 240 V AC 6300 W 600 V 210-480V 125 - 500 V 125V/ 150V 3OA/ I5A Accessories 2/2 Speedwim/Webconnea RS485 interface interf- DM.AB5CB-US-10 SWDf tUS. 10 208 V / • 240 V / • 208 V / • 240 V / • 208 V/ • 240 V/ • , 163 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz Fan kit for 7US-22 00) 22A 25A 29.2A 32A 4000/sooOnusn 1 1 1 FANKIT02.10 1/2 1/2 1/2 • Standard Feature O Optional feature - Not available Data at nominal conditions 97.2% 97.6% Sunny Boy 7000TL-US Sunny Boy 770OTL-US 208 V AC 240 V AC 208 V AC 240 V AC 7300 W 8000 W 600 V 600 V 245 - 480V 270 - 480V 125 - 500 V 125 - 500 V 125V/ 150V 125 V/ 150V 30A/ 18A 30 A/ 18A SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US-22 SB 770OTL-US-22 3 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V/ • 240 V / • 208 V / • 240 V / • 208 V / • 240 V / • 208 V/ • 240 V/ • , 163 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 183 - 229 V 211 - 264 V 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 22A 25A 29.2A 32A 1 1 1 1 1/2 1/2 1/2 1/2 <4% <4% <4% <4% 97.2% 97.6% 97.0% 97.4% 96.8% 96.8% 96.8% 97.3% 96.5% 97.0% 96.5% 97.0% 96.56 965% 96.5% 14EGGE EMCTRICAL CONTRACTORS, INC. • CA LIC. # 748171 JIM HEDGE i • • mo I i Iv Signature r1fle 490/519/185 (19.3/20.5'/7.3) 187/297/190 (7.4/11.7/7.5) 617 / 597 / 266 (24.3 / 23.5 / 10.5) 370/240/280 (14.6/9.4/11.0) 24 kg (53 Ib) / 3.5 k8 18 Ib) 27 kg (60 Ib) / 3.5 kg (8 Ib) -40'C...+60'C {-40'F...+140'F) < 29 dB(A) < 29 dB(A) < 29 cIB(A) < 29 dB(A) <1W <1W <1W <1W Transformerless Transformerless Transformerless Tronsformedess Convection Fan Fan Fon NEMA 3R NEMA 3R NEMA 3R NEMA 3R • • • • 0/0 0/0 0/0 0/0 6/0/0 0/0/0 •/O/O 0/0/0 UL 1741, UL 1998, UL 16998, IEEE1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 SB 5000TL-US-22 SB 6000TL-US-22 SB 7000TL-US-22 SB 770OTL-US-22 3 Renc%S,-*,.*.ia vilusil High Module Conversion Efficiencies Easy Installation and Handling for Various Applications Mechanical Load Capability of up to 113 psf (5400 Pa) Conforms with IEC 61215:2005, IEC 61730: 2004, UL 1703 PV Standards 1509001, OHSAS18001, IS014001 Certified Application Class A, Safety Class II, Fire Rating C 0 100% C (') 95% i7 90% m C: 85% m E 0 80% t aL o% Also Applicable For Module With Black Frame 0 1 5 10 15 NEGGE ELECTRICAL CONTRAC MRS, INC. YEAR CA LIC. # 748171 ❑ APPROVED PRODUCT c n�HE f IV u cOus ❑ J PV CYCLE LISTED ^mss \` IntMdt p /►�� Signature 2gp -77 5"- Slgs'r" T& ReneSolaxom 14 ReneS-*.ia 300W. 305W. 31OW Dirnenslons I-V Curves � ,. 39.1inches 1.6 inches 373 4c)ies Drawing Only for Reference 0 10 zo 0o w s0 Volle0e M Imadlance 200W/mz 400W/mr 600Wfmr 800W/mr IGWWfm2 Efficiency 15.8% 16.2% 16.2% 16.1% 16.0% Maximum Power (Pmax) 300 W 305 W 310 W Power Tolerance - 0-a5W 0 -+SW 0-+5W Module Efficiency 15.5% 15.7% 16.0% Maximum Power Current (Imp) 8.20 A 8.33 A 8.38 A Maximum Power Voltage (Vmp) 36.6 V 36.6 V 37.0 V Short Circuit Current (Isc) 8.69 A 8.73 A 8.80 A Open Circuit Voltage (Voc) 44.8 V 44.9 V 45.0 V Values at Standard Test Conditions STC (AM1.5, Irradiance 1000W/mi, Cell Temperature 7rF) lec 11 1 1 Maximum Power (Pmax) 222 W 226 W 230 W Maximum Power Current (Imp) 6.67 A 6.72 A 6.80 A Maximum Power Voltage (Vmp) 33.4 V 33.6 V 33.8 V Short Circuit Current (Isc) 7.02 A 7.04 A 7.10 A Open Circuit Voltage (Voc) 41.9 V 42.0 V 42.1V Values at Normal Operating Cell Temperature, Irradiance of 800W/m+, AM3.5, Ambient Temperature 680F, Wind Speed Im/s. Mechanical Characteristics Cell Type 6Inches Vlrtuss II (Polycrystalline), 72 (6x12) pa In Characteristics series Temperature Coefficient of Voc -0.167%rF (-0.30%/°C) Glass High Transmission, low Iron, Tempered Glass Temperature Coefficient of Isc 0.022%/°F (0.04%/°C) Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax -0.222%/°F (-0.40%/°C) Junction Box IP65/IP67 Rated, With Bypass Diodes Nominal Operating Cell Temperature (NOCT) 113 2 3.61F (4S 2 2°C) Dimension 177 x 39.1 x 1.6 inches Output Cable 12 AWG, 47.2 inches Weight 59.5 lbs Installation Hole Location See Drawing Above Packing Information Container Maximum Ratings 20' GP 4d GP 4D HQ Operating Temperature -00°F-+185°F(-00°C-+85°C) Pallets per Container 10 24 24 Maximum System Voltage 600VOC (US) Pieces per Container 250 600 660 Maximum Series Fuse Rating 20A (US) aa.-VIDS/2010OS -- Uutnic.W vnn,n.rla. o.,y„w,o«m„mo,.e wdai m dunro.�Jwm vw rob.. , INC. CA LIC. # 748171' JIM HEGGE 06-S- JIM ReneSolaxom 3" CA LIC. # 748171 JIM HEDGE IN'RAr- mRS, INC. t9/i" ® Signature 76c� - 7 �s- �1bs'� Title 00 00000 00 Installation Detail ©2008 UNIRAC. INC. SolarMount Rail 1411 BROADWAY BLVD NE ALBUQUERQUE. NAI 87102 USA L -Foot PHONE 505.242.6411 Standoff Connection UNIRAC_COM URASSY-0001 \%AutoC-�3d Detoil LiGrory\CAO\URASSY-0001_};n klvmnum tJndoll-1 Fool-Stondord Roil.dwq. 8/22/200B 9:44:2 AM 3/8-16 SS FLANGE NI 3/8-16 X 3/4" SS HEX NUT 1, HEGGE ELECTRICAL CONTRACTORS, INC. 44 CA LIC. # 748171 JIM HEGGE O O OUM RCQ Siguatur ��o-�2s X85 '" rifle Sol arMount/SunFrame @2008 UNIRAC. INC. 1411 BROADWAY BLED NE 4" Aluminum AOUOUEROUE, Nu 87102 USA Serrated PHONE 505.242.6411 uNIRAc.coM L -Foot UNIRAC-310077 t:r 0 N N 1 0.75— I HEGGE ELECTRICAL CONTRACTORS, INC. CA LIC. # 748171 JIM HEGGE CAre Signator 76D -7 7 S-- rifle 00 000IN 00U-NSolarMount @2008 UNIRAC. INC. Standard Rai! 1411 BROADWAY BLVD NE ALBUOUEROUE, NM 87102 USA PHONE 505.242.6411 UNIRAC.COM UNIRAC-300001 J 3/8-16 X 3/4 FLANGE HEAD -DERRATED BOLT 03/8 EPDM WASHER .75" ALUMINUM TANDOFF TUBE 5/16 X 3-1/2 LAG BOLT ALUMINUM ;TAND6FF BASE HEGGE ELECTRICAL CONTRAcroR4, wc. CA LIC. # 748171 JIM HEGGE 2x ' —25 Signature ?OD_7zs-f 7 ride 000RAC 00OUN SolarMount/SunFrame @2008 UNIRAC. INC. 3" Aluminum 1411 BROADWAY BLVD NE ALBUQUERQUE NIA 87102 USA Standoff PHONE 505.242.6411 UNIRAC.COM UNIRAC-310503 s L +� 3/8-16 X 3/4 HEX HEAD BOLT 3/8-16 FLANGE NUT HEGGE ELECTRICAL CONT ACMpSg fNC. CA LIC. # 748171 JIM HEGGEi� /ice R 000 M � Signature ?do-7zr Vs-s—Title 00UC Installation Detail © 2008 UNIRAC, INC. SolarMount Rail 1411 BROADWAY BLVD NE ALBUOUEROUE, NM 87102 US4 L -Foot Connection PHONE 505.242.6411 UNIRAC.COM URASSY-0002 1 Bin # City of La Qulnta. Building 8t Safety Division P.O. Box 1504, 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: Owner's Name: A. P. Number: Address: Legal Description: City, ST, Zip -1 k QIJe cA • S`'3 Contractor: eePhone. Address: S r S VG Project Description: City, ST, Zip: ikO 0A c Telephone: P S" 7 7 7 r -d ��JL. State Lic. # : 7 V$ I Z 1 Arch., Engr., Designer: !SO 04 City Lie. #; Address: City,, ST, Zip: Telephone:hone• a St to Lie. # Name of Contact Person:ou Construction Occupancy: TY cY• Type: r Demo Project type (circlea one): New Add'n Alter Repairai + �V.. ` S # Stories: FwUnits: Telephone #,of Contact Person: stimated Value of Project: 6-1-V APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING PERMIT FEES. Plan Sets PIan Check submitted JucalAmount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Coles. Called Contact Person Plan Check Balance, Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2-d. Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN ROUSE:- 'rd Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees F 148' 1 Gleason Residence PV Syster 8.4 KW Layout CEC-AC Ra SINGLE LINE DIAGRAM 225 Ampi Main Service 240 Volt Single Phase 3 Wre All Residerijial Breakers Kabed @ $QKAIC Existing Meter # 11D-164SR•147421 Proposed(M) Bidirectional Me"M - W012 Main Zh DL-gate Main Breaker To Comply w! 120% Rule 25/2 PV-1 9 (lsoe Load Caic compliance) 2512 PV-2 Circuit Schedule PV Array 1 & 2 ting 7.381 KW TO PV ARRAY 30 Amp SMA SB400OUS 30 Amp 30 Amp AC Disc 1lw1 Integral GFCI-AFCI DC Disc& AC Disc 71 INVERTER I a 25 Amps Eased SMA Accessory DC Disconnect Non -Fused Typ. i 30 Amps Fuse PV FUSED COMBINER BOX @ ROOF TO PV ARRAY MA SB400OUS 30 Amp w/ lntegral GFCI-AFCI ❑C DiscA INVERTER 20,4 sew 25 Amp Fused #4 CU To 5/8 x 8 Gnd Rod IUISB To A/C Disc 3 #10 TiHHN + #10 GND &I SC Rating 8.69A x 125% = 10.86 x 2 Strings = 21.72A Per CEC 690,8(A)1 A1C To Inverter 3 #10 THHO + #10 I ND A Same as above (IInverter To Array Fused Combiner Box 2 ##10 U E2 CU + #10 GND & Per CEC 690.8(B)(7 )) ISC x.1 25 x 125= 13-58 x 2 Strings=27.15 Amps Use #10 THHN USE2 VOC Rating 44.8 x 7 Panelsi Per String = 313.6 V x Ternp Adj. 1.12 = 351.23 Volts CEC 690,7 i AH wiring runs type 1,2,3 iris, alled in 314" Flexible et;Y, Conduit Sizing per Annex C Table C.3 PV Arr ry 1 SMA S84000US Inverters Required Signage 14 Rennes tar America jr.-moRA 241Ax 2 Strings I f 7 ISC Singl String 8.69 x 125% = 10.86 Amps ISC In Pa �alell 8.69 x 2 x 125% = 21.73 Amps Racking System: Unirack See Attached Cut Sheets I JPF r -Odle CAUTION THIS SERVICE IS SERVED BY AN ALTERNATE SOURCE OF POWER CAUTION SOLAR PV SYSTEM DISCONNECT -AC CAUTION SOLAR PV SYSTEM DISCONNECT -DC rris6o ffj1EU&W. i I L-S7] 30 Amp Fusel FV FUSED COMBINER BCX @ ROOF Required Signage At Inverters WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZE❑ All construction shall comply with the 2013 California Building, Residential, Mechanical, Electrical, Plumbing, energy, and Green Building Code. HEDGE ELECTRICAL CONTRACTORS INC 83-852 AVE. 45 INDIO, CA. 92201 LIC# 748171 JIM FIEGGE 760-775-4855 d C [1} 0 45 IC 11� U C"� CD a) X:coC: _j Rev. Date 7/20/2015 8111 12015