Loading...
08-1413 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 08-00001413 Property Address: 80992 BELLERIVE APN: 775-350-002- - - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 68198 C&tyl 4 4v-�Q" Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. LicensepClass: 748605 License No.: 13 Date` ! St• Contractor: X4410if i OWNER-BUILDDECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERn4IT Owner: WARD 80-992 BELLERIVE LA QUINTA CA LA QUINTA, CA 92253 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/23/08 Contractor: n V LANG CONSTRUCTION 80590 CAMINO SAN GREGE BERMUDA OU834D020 CA 92203 (7 FjNgHC oQ�/Nr Lic. No.: B FAt'9 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will1maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 1889409 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: q ve Applicant: Xuwa1� WARNING: FAILURE TO SECURE WORKERS' COMPEN TION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Date:_ '�2¢ 08 Signature (Applicant or AgenO: 24",e W d4yf =4 Application Number . . . 08-00001413 Permit BUILDING PERMIT Additional desc . . Permit Fee . . . . 500.00 Plan Check Fee 325.00 Issue Date . . . . Valuation . . . . 68198 Expiration Date 3/22/09 Qty Unit Charge Per Extension BASE FEE 414.50 19.00 4.5000 THOU BLDG 50,001-100,000 85.50 ---------------------------------------------------------------------------- Permit ELECT - ADD/ALT/REM Additional desc . . Permit Fee . . 44.16 Plan Check Fee 11.04 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/22/09 Qty Unit Charge Per Extension BASE FEE 15.00 833.00 .0350 ELEC NEW RES.- 1 OR 2 FAMILY 29..16 ---------------------------------------------------------------------------- Permit GRADING PERMIT Additional desc . . Permit Fee . . . . 15.00 Issue Date . . . . Expiration Date . . 3/22/09 Plan Check Fee Valuation . . Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit MECHANICAL Additional desc . Permit Fee . . . . 46.00 Plan Check Fee 11.50 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/22/09 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 2.00 ---------------------------------------------------------------------------- 6.5000 EA MECH VENT FAN 13.00 Permit Additional desc LQPERAIIT PLUMBING ' -4 >-a Application Number . . . . . 08-00001413 Permit . . . . . . PLUMBING Permit Fee . . . . 76.50 Plan Check Fee 19.13 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/22/09 Qty Unit Charge Per Extension BASE FEE 15.00 8.00 6.0000 EA PLB FIXTURE _ 48.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4'OUTLETS 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 833 SQ. FT. CASITA.ADDITION WITH 67 SQ. FT. PATIO I --------------------------------------------------------------------------- Other Fees . . . . . . . . ENERGY REVIEW FEE 32.50 STRONG MOTION (SMI) - RES 6.81 Fee summary Charged Paid Credited Due --------------------------- Permit Fee Total 681.66 ------------------------------ .00 .00 681.66 Plan Check Total 366.67 .00 .00 366.67 Other Fee Total 39.31 .00 .00 39.31 Grand Total 1087.64 .00 .00 r 1087.64 ' O LQPEPWIT Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVELONEAMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMMIIND. AMOUNT: DATE: RECEIPT: CHECK #: INITIALS: CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: BARD Date: September 24, 2008 Owner's Name: WARD Phone No. (760) Project Address: 80-992 Bellerive, La Quinta, CA 92253 Project Description: Casita Addition APN: 775-350-002 Tract #: Lot #'s: Type of Development: Residential XX Commercial Industrial Total Square Feet of Building Area: 833 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: 09/24/08 Signature: Ze-5 sssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssss SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq.Ft. 833 sq. ft. Amount per Sq.Ft. $ 0.00 Amount Collected $ 0.00 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Support Services Certificate issued by: Leticia C. Torres, Facilities Analyst Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to the Sunrise Agreement signed in 1986 the; referenced residence was previously charged a one time fee; of $628.00 therefore exempt from any fees for additions. Section 66020 of the Government Code asserted by Assembly Bill 3081, effective JanuaryT, 1997, requires that is D' 'ct provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires, if a building permit has not been issued for the project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance less 3% for Administrative Fees to process the reimbursement. MV:c/m�•docs/devfees/certificate of compliance form tablesTO OSE.doc 1/16/03 T 3 Gr; 1 Ui Luo •iw V L iU Ifd rionarca IVlanao8�llf'-nt . Y11 :11'�•:r A.y '.f �.s!.�'• FAIRWAYS ASSOCIATION September 10, 2008 James & Leslie Ward 80-992 Belledve La Quinta, CA 92253 Re'. Axclhitectural Application - 80-992 Bellv ive - APPROVM Dear W Ward: 'Ile Architecu=1 Committee reviewed 7ouz plans submitted fox the consauctiot of pour Casita. I am phased to notify you that the Archiftctntal Committee has approved pour applisyation as submitted. When completed with youx project, please fill out an Farb it C £otm and send into the office for Final Inspection of your property. If you sho-uld have any questions in regard to this correspondence please do not hesitate to contact the Association atany time. Sincerely, Or behalf of rih8 PGA WE.i'T.AJssxia 6n •A. trhi,lwkral / ComndMe Bp: Jamie $"vat PGA WEST Fairways Opexatioas Manager For the Archie eetuxal Committee C.C. Floc Post Office Box 1690 • La Qui,;ata, California 92247 - Phone (760) 776-a 100 - Fax (760)'1176-5 111 Ri T TITLE 24 REPORT Title 24 Report for: WARD CASITA 80992 BELLERIVE LA QUINTA, CA 92253 Project Designer: LANG CONSTRUCTION LARRY W. LANG 760-702-7744 Report Prepared By: KAY THOMAS T&K Engineering 30535 Ave. Buena Suerte Temecula, CA 92591 (951) 699-0436 CITY OF LA QUINTA BUILDING & SAFEY DEPT. APPROVED FOR CONSTR ON DAT �k�10B Job Number: 8-11-08 Date: 8/11/2008 fol% l, g � N:Tl AUG ] 5 2008 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 4.4 by EnergySoft Job Number: 8.11-08 User Number: 3089 i Certificate Of Comaliance : Residential (Part 1 of 4) CF -1 R 1NA_ RD__CAS_I.TA..._....... _-------- _ _.___.___ 8/11/2008 Project Title Slab on Grade Area: Fenestration: Date _-_.__._ MQ92_BELLEaVE—LA_Qlll NTA Avg. U: 0.34 Number of Dwelling Units Project Address Avg. SHGC: 0.39 Number of Stories: Building Permit # _T_&K__E.n.Q.ineeri.n.g—_____ Documentation Author Zone Name Floor Area Volume (951) 699-0436 `Plan Check/Date Telephone -Ener_gPto-- Complia ce Method ----.._.._....------.--____....---._____ -A.00- - CA Cli.mateJ�ne�� Field cnecWDate Climate Zone - __.........-__ _....... TDV Standard Proposed Compliance (kBtu/sf_yr) _._...._....—......__._.._._... Desi ...... - -- Space Heating 1.73 0.36 1.37 Space Cooling 77.11 78.33 -1.22 Fans 11.00 12.20 -1.20 Domestic Hot Water 20.69 17.56 3.13 Pumps 0.00 0.00 0.00 Totals 110.53 108.45 2.08 Percent better than Standard: 1.9% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: XI Single Family ( Addition Total Conditioned Floor Area: 833 ft2 Multi Family ❑ Existing + Add/Alt Existing Floor Area: n/a ft2 Building Front Orientation: -Conditioned-- (E) 90 deg Raised Floor Area: Fuel Type: Natural Gas Slab on Grade Area: Fenestration: . _............. __.Q_ _....... _.... 22 Average Ceiling Height: Area: 194 ft2 Avg. U: 0.34 Number of Dwelling Units Ratio: 23.3% Avg. SHGC: 0.39 Number of Stories: BUILDING ZONE INFORMATION # of Zone Name Floor Area Volume Units Zone Type .3SON..H.V.AC—__.._.......__-__.__.._.._.__._ ______-..833 —8 330 -A.00- - OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. - -- Cay. Cont. Azm. Tilt ..._...---...__..._ .................. _........ -....... ._... --- .Roof......__ .V .V..00c — 833.—Q.025--R=38--R=0-0 . _............. __.Q_ _....... _.... 22 Wall. Wood .___.... _ .__............... 1.7.8_ ...... 0-069- .._R_2.1.._RD-.0 —90_ _90 ...__...... 298_ ._._D.D69........._R21—R=QAL tan —9.Q Wall— Wand_ 69 .._0-069 _.R-.21..._.R:O..Q_.._.._270_9.Q Wall— Wood_ �.2Z6_ .__.0..0.69_.._..._R 2]....._R_Q.D_D —9D Gains Condition Y / N Status JA IV Reference 0 ft2 833 ft2 10.0 ft 1.00 Thermostat Vent Type Hgt. Area ....... Setback —_ 2 —nla Location / Comments 01 -AIR ENII&E_GASl.IA... -_... ___.___........................ __.__. Il9_A6_........ _.......... _.._._...................ENIlRE_r.ASITA _. 0.9 ___............ .. ENTIRE GASITA 09 -AR ENItRE..CASI_TA_ —_. ENURE CARITA i EnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: 8-11-08 Page:3 of 9 1 Certificate Of Comaliance : Residential (Part 2 of 4) CF -1 R WARD CASITA _____........__.._ 8/1.1/2008 Project Title Date FENESTRATION SURFACES Area Thick. Heat Inside Condition Location/ Type (sf) True Cond. Location/ # Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing TypeComments 1_._....Wind.ow___.Ero.nt...__....(E)._ ......... _.89...0_ _0-34.0-NFRC.._0.3.9 _NERC —9L _9Q New Mdgardlow E or Enuiv FNTIRF CASITA 2 Window Left (S) 44.0 0.340 NFRC 0_39 NFRC 18090NewMilgard._Low_E.orEguiv_ .......... _..__ .................. _ ENTIRE _CASITA _._ .30 66.0 ..._0 340.NFRC _0, 39 ._NERC _.. 0.....__90.. New Milgard Low E or Equiv._ _...___._ ENTIRE CASITA_. Type Length R -Val. Location _ JA IV Reference Status Comments ... _._ _ Slab Perimeter 29 None No Insulation 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168 THERMAL MASS FOR HIGH MASS DESIGN EnergyPro 4A by EnergySoft User Number: 3089 Job Number: 8-11-08 Page:4 of 9 Area Thick. Heat Inside Condition Location/ Type (sf) (in:) Cap;Cond. R -Val. JA IV Reference Status Comments _ Insulation Condition Location/ PERIMETER LOSSES Type Length R -Val. Location _ JA IV Reference Status Comments ... _._ _ Slab Perimeter 29 None No Insulation 26-A1 New _._ ENTIRE CASITA __— Slab Perimeter 58 None No Insulation 26-A1 New ENTIRE CASITA EnergyPro 4A by EnergySoft User Number: 3089 Job Number: 8-11-08 Page:4 of 9 Certificate Of Comaliance : Residential (Part 3 of 4) CF -1 R WARD CASITA 8/11/2008 Project Title Date HVAC SYSTEMS Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type 3 TON HVAC Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER New Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? 3 TON HVAC Ducted Ducted Attic 4.2 New No Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. Gas 50 gal or Less Small Gas No Pipe Insulation 1 40,000 50 New 0.65 n/a n/a Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (� Add 1/2" Control # HP Tvoe In Plenum Outside Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: LANG CONSTRUCTION Address: LARRY W. LANG Telephone: 760-702-7744 Lic. #: (signature) (date) Enforcement Agency Name: .Title/Firm: Address: Telephone: (signature) Documentation Author Name: KAY THOMAS Title/Firm: T&K Engineering Address: 30535 Ave. Buena Suerte Temecula, CA 92591 Tele hon (9511699-0435 Q (sig ture) (date) Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R WARD CASITA 8/11/2008 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require. special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. I -Plan--] Field The Roof "R-38 Roof Attic" includes credit for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual. . . ............ . ........... ........... . ............. . . ..... . .... .......... . . ......... . . ........ . . . ........... . - ------- . . .......... ...... . ......... . . . . . . ..... . . ............. . . . . ..... . .. . ........ . ............... . . ..... . . . . . .......... . .. . ........... . ...... HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a HERE provider using approved testing anwor veritication metnoos. --Fi-1in'-­ Fkeij-] The HVAC System "3 TON HVAC" incorporates a HERSverifiedRefrigerant Charge test or a HERS v-eTiFie-�a­TF-e—rmostatic Expansion Valve. ............. ....... . .... . . ..... ... .. . . ..... . This building has credit for insulation Quality Installation. A certified HERS rater must visually verify the installation of all Insulation. The Cooling System "3 TON UNIT" includes credit for a 10.9 EER Condenser. A certified HERS rater must field verify the installation of the correct Condenser. ........ — ---------. . . . ............... . . . .......... — - - - ------ ---------- ----- - ---------- - --- - - ---- --- -------- - . . . ...... ............ . — ------ . . . . . ....... - ------- - -- - — - - ------------- - EnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: 8-11-08 Page:6 of 9 —i Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE permit application documentation. NIA DESIGNER MENT Building Envelope Measures ! § 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. U EX 1 0 § 0150(b): Loose fill insulation manufacturer's labeled R -Value: I� ID;__._ 1 § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑j apply to exterior mass walls). T§ 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent 1.1 -factor, F_.I FX) 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ L L.__! j 1. Masonry and factory -built fireplaces have: �..I �._^_I IJ a, closable metal or glass door covering the entire opening of the firebox f tt t b. outside air intake with damper and control, flue damper and control L) ! X: OR, I 2. No continuous burning gas pilot lights allowed. I,.] � X II E"! § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. L__1 01 11 § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. D 0:-1 § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor 0 0 ! permeance rate no greater than 2,0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include f CF -6R Form: ._.....__.___.____........................ ...... -........ LJ 1 § 116-17: Fenestration Products, Exterior Doors, and InfiltrationlExfiltration Controls. 1, Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. I___1 i.Xj ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain tf 0 11 Coefficient (SHGC), and infiltration cerlification. 1... 3. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. ❑ ..._..., i x! f..-_.1 i—j Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ L L.__! j § 150(i): Setback thermostat on all applicable heating and/or cooling systems. �..I �._^_I IJ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation 0 ����,, El ❑ I having an installed therms/ resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external �_.� ❑ I—I insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and LJ 1 indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ r❑11 C.1 and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ED tf---ll F0 r I entirely in conditioned space. Corporation. U 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification 1EnergyPro4.4 b Ener Soft User Number: 3089 Job Number: 8-11-08 _ Y EnergySoft Page:7 of 9 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE- j DESCRIPTION applicable. _ NIA DESIGNER MENT 'Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans Lighting Measures 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, Elt_�l l� D 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, t [E] R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. of UL 723. If mastic or tape is used to seal openings greater than 114 inch, the combination of mastic and either mesh or f� OR are controlled by an occupant sensor(s) certified to comply with Section 119(d). tape shall be used. l�-1 by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed El ❑X f , sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support ❑ `�! _J same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. _ ❑ U 1 in the cross-sectional area of the ducts. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with Goth back rubber adhesive ❑ 3 iX_I (� C duct tapes unless such tape is used in combination with mastic and draw bands. ❑ r (� 4. Exhaust fan systems have back draft or automatic dampers. — 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment El I�-''xJ ❑ maintenance, and wind, Cellular foam insulation shall be protected as above or painted with a coaling that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ ❑ 7, Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: Ci ❑ ❑1--- a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. El E._i --11 3. Pool system has directional inlets and a circulation pump time switch. 0 L._.t L -I § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously X( burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)1: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ )Q ❑ j 150-C, and do not contain a medium screw base socket (E24IE26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, t [E] luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. f� OR are controlled by an occupant sensor(s) certified to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms. and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled) l�-1 by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ I nJ _1 certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ `�! _J same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. _ ❑ U 1 Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). .................. —._.._.__..._...._.__ ....... _. __ _ IEnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: 8-11-08 Page:8 of 9 —_ HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ... .......... PROJECT NAME DATE WARD CASITA 8/11/2008 SYSTEM NAME T FLOOR AREA - I_..___.___..__.__ 3 TON HVAC 833 ENGINEERING CHECKS SYSTEM LOAD — . ._..._.- Number of Systems —_ I J. Heating System 1COIL COOLING PEAK_.._ COIL HTG. PEAK _; CFM Sensible Latent CFM Sensible --.._.._.._..--....._._.__..........._.......__....._.....—.._._� j + Output per System -- `56,000 _.. __._. _. . _ _ f_........—._..._._.. __._._.....- -- ...1.- - ..__....--......) i_._....._.........._._j� Total Room Loads ! 669 13,5191 673 ; 3311 12,311.' _ _- f_..._-.._�__..__._....._...._._.._. �— Total Output (Btuh) 56,0001 Output (Btuh/sqft) 67.2 1........__._...._..__.._........_._.._........._.............._.._.......__......__._....._._..-_ I r ---................_.....__.......__......._.._..........__...__..................__..__...----.......- - -- Cooling System--- II , Return Vented Lighting Return Air Ducts 2,1021 1,579 i Return Fan 0 0 1 i Ventilation 29 1,088 22 29 1,315 1 Output per System 36,000 Total Output (Stuh) 36,000 Supply Fan 0 0 Supply Air Ducts 2,1021 1,579: TOTAL SYSTEM LOAD 1s s1z—s5_ I_ s,785 Total Output (Tons) 3.0 Total Output (Btuhlsgft) 43.2 - TotalOutput (sgft/Ton) 277.7 ---- ----- ---- - -------.-.._...... ---------- ------------ __........... ---- -- - ... - -- - --------i 1,Air System ------------- HVAC EQUIPMENT SELECTION CFM per System 1,300 -- Airflow (cfm) 1,300 -------- _---- ......_.__._......__......_..- -....._.._................. ..---........... --._...._.J.._...._..._... -............ 3 TON UNIT 24,613 6,017 56,000; - -- -- - ---r Airflow(cfm/sgft) 1.56 - ..... --...__..._._...... __.... __....... --- .......... ---.._._._.......... ....................... _........... _._... ---- _— _i Total Adjusted System Output 24,613, 6,0171 56 000 (Adjusted for Peak Design Conditions) i----- -- -= - - I Airflow (cfm/Ton) 433.3 Outside Air °�° - ( ) 2.2 Outside Air (cfm/sgft) j 0.03 --- - - ._...-----.............._. TIME OF SYSTEM PEAK ( Au 2 m Jan 12 am 1...__. _..... 9 . p .. I - Note: values above given at ARI conditions j EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak i 26.0 of 67.9 of 67.9 of 105.0 °F Supply Air Ducts O j Outside Air 29 cfm 1039 of Supply Fan Heating . Coil ---.. 1300 cfm ..__.ROOMS j 70.0 of 68.9 of j I Return Air Ducts DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak ill 1.0172.5 of 76.3 / 61.9 of 76.3 / 62.0 of 55,0 153.8 of Supply Air Ducts Outside Air ' 29 cfm Supply Fan Cooling Coil 56.5/54.4 of 1300 cfm ROOMS] 48.1% R.H. 75.5!61.7 OF 74.0161.10F ; Return Air Ducts ' i i EnergyPro 4.4 by EnergySoft User Number: 3089 Job Number: 8.11-08 -- —` - Page:9 of 9