10-0141 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
Property Address:
APN:
Application description
Property Zoning:
Application valuation:
Applicant:
10-00000141
52395 AVENIDA BERMUDAS
773-275-016-6 -000000-
REMODEL - RESIDENTIAL
COVE RESIDENTIAL
7232
Tit!t 4 4 Q"
Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
_�cense`Class:
`C'39 �.�/�Liic�ensee*: 447W9
' Date: 1 /,�Z� /A Contractor V K>�
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPER111IT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 3/04/10
Owner:
STEVENS JAMES, R.
52395 AVENIDA BERMUDAS
LA QUINTA, CA 92253
( WCIFINOO Contractor:DESERT VALLEY CONSTR594 W. 7TH STREET
SAN JACINTO, CA 9258(951)654-1980
Lic. No.: 447139
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 238003156
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
�aanndd�agree that, if I should become subject to the workers' compensation provisions of Section
the ith those pr ions.
Date: pplicant
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating t&�Idin M�nstru�tion, and hereby Guth ize representatives
of this county to/�ente�r upon the above-mentioned prtion pose
Date: ��� Signature (Applicant or Agent):
Application Number . . . . . 10-00000141
------ Structure Information PATIO CONV TO DEN
-----
Construction Type . . . . . TYPE V, UNPROTECTED
Occupancy Type DWELLG/LODGING/CONG <=10
Other struct info . . . . . CODE EDITION
2007/08 energy
# BEDROOMS
----------------------------------------------------------------------------
.00
Permit . . . BUILDING PERMIT
Additional desc . . 125 SF PATIO CONVERSION TO DEN
Permit Fee . . . . 99.00 Plan Check Fee
64.35
Issue Date Valuation . .
. . 7232
Expiration Date 8/31/10
Qty Unit Charge Per
Extension
BASE FEE
45.00
6.00 9.0000 THOU BLDG 2,001-25,000
----------------------------------------------------------------------------
54.00
Permit . ... ELECT - ADD/ALT/REM
Additional desc . .
Permit Fee . . . . 27.63 Plan Check Fee
6.91
Issue Date . . . . Valuation . .
. . 0
Expiration Date 8/31/10
Qty Unit Charge Per
Extension
BASE FEE
15.00
125.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY
4.38
11.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20
----------------------------------------------- ------------------------
8.25
Permit . . . MECHANICAL
Additional desc . .
Permit Fee . . . . 19.50 Plan Check Fee
4.88
Issue Date .. . . . Valuation . .
. . 0
Expiration Date 8/31/10
Qty Unit Charge Per
Extension
BASE FEE
15.00
1.00 4.5000 EA MECH VENT INST/ DUCT ALT
4.50
----------------------------------------------------------------------------
Special Notes - and Comments
125 SF PATIO CONVERSION TO DEN / LIVNG.
TYPE V -B CONSTRUCTION, R-3 OCC. 2007
CODES / 2008 ENERGY. REFERENCE CODE CASE
` 09-6829.
--------7-----------------------------------------=-------------------------
Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473)
1.00
LQPERMIT '
Application Number . . . . . 10-00000141
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY REVIEW FEE 6.44
STRONG MOTION (SMI) - RES .72
Fee summary Charged
Permit Fee Total 146.13
Plan Check Total 76.14
Other Fee Total 8.16
Grand Total 230.43
LQPERMIT
Paid Credited Due
.00 .00 146.13
.00 .00 76.14
.00 .00 8.16
.00 .00 230.43
&n # y
City of La Quinta
BwMing 8[ Safety Wvislon
P.O. Box 1504, 78-495 Calle Tampko
La Qidnta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
S L
Project Address: J 2 301
Owner's Name S v SNS
T
1 ,J 0
A. P. Number:
Address-.� C rlf�fo
Legal Description:
City. ST' gyp' 1
Contractor:) vAI lV
Address:n
Telephone: —) (
J
1'rojecx Vl
City, ST, Zip:
1DesaiPtion:
`Vl[` QV1N zq-0000
Telephone:
City Lia C �
State Lic. #: Z 56 bb 315-
Arch., Engr., Deni '
�U5
Address:
City, ST. Zip:
Telephone: Construction Type: Occupancy:
State Lic. #: Project type (circle ore): New Add'n Alter Repair Demo
Name of Contac Person: Sq. FL: #Stories: N Units:
Telephone # of Contact Perso
— (oS Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
0 Submittal Req'd Rex'd TRACKING PERMIT FEES
Plan Sets
Plan Check submitted 6 Item Amount
Structural Cala
Reviewed, ready for correction Plan Check Deposit
Truss Cala.
'
Called Contact Person Plan Crede Balance
Title 24 Cala.
aw picked up Construction
Flood plain plan
Plans resubmitted Mechanical
Grading plan
Z'! Review, ready for correctio ue 3 Electrical
Subeontaetor List
Called Contact Person Plumbing
Grant Deed
Plans picked op S.M.L
H.O.A. Approval
Plans resubmitted Grading
IN ROUSE:-
''' Review, ready for correctlonslIissucDeveloper Impact Fee
Planning Approval
Called Contact Person A.LP.P.
Pub. Wks. Appr
Date of permit Issue
School Fees
Total Permit Fees
I BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Stevens Residence
52-395 Avenida Bermudas
La Quinta, CA
.. Project Designer:
0
RIECMIVED
BY:
Report Prepared by:
Joan D. Hacker
Insu-form, Inc.
77-810 Las Montana Road, Suite 210
Palm Desert, Ca 92211
760-345-1352 (�v i 1'� TA
Cf"fY OF � FETY DEPT.
BUILDING & SA
APPROVED
FOR CONSTRUCTION
DATE 08
/D BY �'----
FEB 2 5 2010
Job. Number:
Date:
2/24/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
HVAC System Heating and Cooling Loads Summary
1
2
3
9
12
EnergyPro 5.0 by EnergySoft Job Number. ID: User Number. 2655 1
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stevens Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
2124/2010
Project Address
52-395 Avenida Bermudas
La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,627
Addition
125
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes IZI No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes IZI No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavity (ft) Features see Part 2 of 5 Status
Slab Unheated Slab -on -Grade
None 1,502 Existing
Wall Wood Framed
R-11 1,128 Existing
Door Opaque Door
None 20 Existing
Roof Wood Framed Attic
R-19 '1,502 Existing
Slab Unheated Slab -on -Grade
None 125 New
Wall Wood Framed
R-13 140 New
Roof Wood Framed Attic
R-19 125 New
FENESTRATION
Orientation Area(ft)
U- Exterior
Factor SHGC Overhang Sidefins Shades Status
Front (E) 40.0
0.710 0.73 2.0 none Bug Screen Existing
Left (S) 28.0
0.710 0.73 2.0 none Bug Screen Existing
Left (S) 8.0
0.710 0.73 2.0 none Bug Screen Existing
Left (S) 4.0
0.710 0.73 2.0 none Bug Screen Existing
Rear (IM 16.0
0.710 0.73 2.0 none Bug Screen Existing
Rear (IM 40.0
0.870 0.70 2.0 none Bug Screen Existing
Rear (W) 16.0
0.710 0.73 2.0 none Bug Screen Existing
Rear (IM 12.0
0.710 0.73 2.0 none Bug Screen New
Right (N) 12.0
0.710 0.73 2.0 none Bug Screen Existing
Right (N) 16.0
0.710 0.73 2.0 none Bug Screen Existing
Rear (IM 48.0
0.710 0.73 2.0 none Bug Screen New
HVAC SYSTEMS
Qty. Heating
Min. Eff Cooling Min. Eff Thermostat Status
1 Central Fumace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
Living Zone Ducted
Ducted Attic, Ceiling Ins, vented 8.0
Existing
WATER HEATING
Qty. Type
Gallons Min. Eff Distribution Status
EnergyPro 5.0 by EnergySoft User Number.' 2655 Run Code: 2010-02-22T15:19:3 ID:
Page 3 of 12
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
Stevens Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
2124/2010
Project Address
52-395 Avenida Bermudas La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
1,627
Addition
125
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION Area Special
Construction Type Cavity (ft) Features see Part 2 of 5 Status
FENESTRATION U- Exterior
Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status
Rear (IM 12.0 0.710 0.73 2.0 none Bug Screen New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R -Value Status
WATER HEATING
Ot . Type Gallons Min. Eff Distribution Status
EnergyPro 5.0 by EnergySoft User Number. 2655 RunCode: 2010-02-22T15:19:3 ID:
Page 4 of 12
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
Stevens Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ❑ Existing+ Addition/Alteration
Date
2/24/2010
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnergyPro 5.0 by EnerqySoft User Number: 2655 RunCode: 2010-02-22T15:19:3 /D: Page 5 of 12
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type m Single Family ❑ Addition Alone
Date
Stevens Residence
1 ❑ Multi Family. m Existing+ Addition/Alteration
1212412010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2- r
Space Heating 8.17 7.95 0.22
Space Cooling 163.97 163.39 0.59
Fans 35.32 35.20 0.13
Domestic Hot Water 20.45 20.45 0.00
Pumps 0.00 0.00 0.00
Totals 227.91 226.98 0.93
Percent Better Than Standard: 0.4
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (E) 320 40
Fuel Available at Site: Natural Gas (S) 260 40
Raised Floor Area: 0 (K9 700 144
Slab on Grade Area: 1,627 (N) 260 28
Average Ceiling Height: 8.0 Roof 1,627 0
Fenestration Average U -Factor: 0.74 TOTAL: 252
Average SHGC: 0.73 Fenestration/CFA Ratio: 15.5%
REMARKS
STATEMENT OF COMPLIANCE
This.certif.icate of compliance lists the building. features. and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company Insu-form, Inc.
2/14/1010
Address 77-810 Las Montana Road, Suite 210 Name Joan D. Hacker
-Wed
City/State/ZipCity/State/Zip Palm Desert Ca 92211 Phone 760-345-1352 Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company
`-�
Address Name ll?
City/State/Zip Phone i d License # Date
EnerqyPro 5.0 by EnemySoft User Number: 2655 RunCode: 2010-02-22T15:19:3 ID: Page 6 of 12
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
Stevens Residence
Building Type m Single Family ❑ Addition Alone
0 Multi Family 10 Existing+ Addition/Alteration
Date
1212412010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Cavity Exterior Frame Interior Frame Azm
Joint Appendix
Tilt Status 4 Location/Comments
Slab
1,502
0.730 None
0
180 Existing 4.4.7-A1
Existing Living
Wall
260
0.110 R-11
90
90 Existing 4.3.1-A2
Existing Living
Door
20
1.450 None
90
90 Existing 4.5.1-A1
Existing Living
Wall
220
0.110 R-11
180
90 Existing 4.3.1-A2
Existina Livin
Wall
200
0.110 R-11
270
90 Removec 4.3.1-A2
Existin Livin
Wall
416
0.110 R-11
270
90 Existing 4.3.1-A2
Existing Living
Wall
232
0.110 R-11
0
90 Existing 4.3.1-A2
Existing Living
Roof
1,502
0.049 R-19
90
0 Existing 4.2.1-A4
Existing Living
Slab
125
0.730 None
0
180 New 4.4.7-A1
Addition
Wall
140
0.102 R-13
270
90 New 4.3.1-A3
Addition
Roof
125
0.048 R-19
180
0 New 4.2.1-A 16
Addition
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type
Location/Comments
1
Window
40.0 0.710 Default
0.73 Default
90 Existing
Double Metal Clear
Existing Living
2
Window
16.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
3
Window
12.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
4
Window
8.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
5
Window
4.0 0.710 Default
0.73 Default
180 Existing
Double Metal Clear
Existing Living
6
Window
16.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
7
JWndow
40.0 0.870 NFRC
0.70 NFRC
270 Existing
Double Mtl Uncoated Default
Existing Living
8
Window
16.0 0.710 Default
0.73 Default
270 Existing
Double Metal Clear
Existing Living
9
Window
48.0 0.710 Default
0.73 Default
270 Removed Double Metal Clear
Existing Living
10
Window
12.0 0.710 Default
0.73 Default
270 New
Double Metal Clear
Existing Living
11
Window
8.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
12
Window
4.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
13
Window
16.0 0.710 Default
0.73 Default
0 Existing
Double Metal Clear
Existing Living
14
Window
48.0 0.710 Default
0.73 Default
270 New
Double Metal Clear
Addition
15
Window
12.0 0.710 Default
0.73 Default
270 New
Double Metal Clear
Addition
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
H t I Wd
Overhang Left Fin Ri ht Fin
Len I H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
6.81 6.0
2.01 0.1
2.0 2.0
2
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
3
Bug Screen
0.76
3.0 4.0
2.0 0.1
2.0 2.0
4
Bug Screen
0.76
2.0 4.0
2.0 0.1
2.0 2.0
5
Bug Screen
0.76
2.0 2.0
2.0 0.1
2.0 2.0
6
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
7
Bug Screen
0.76
6.8 6.0
2.0 0.1
2.0 2.0
8
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
9
Bug Screen
0.76
8.0 6.0
2.0 0.1
2.0 2.0
10
Bug Screen
0.76
2.0 6.0
2.0 0.1
2.0 2.0
11
Bug Screen
0.76
2.0 4.0
2.0 0.1
2.0 2.0
12
Bug Screen
0.76
2.0 2.0
2.0 0.1
2.0 2.0
13
Bug Screen
0.76
4.0 4.0
2.0 0.1
2.0 2.0
14
Bug Screen
0.76
8.01 6.0
2.0 0.1
2.0 2.0
15
Bug Screen
0.76
2.0 6.0
2.0 0.1
2.0 2.0
EnergyPro
5.0 by EnergySoft User Number: 2655
RunCode: 2010-02-22T15:19:3 ID:
Page 7 of 12
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5) CF -1 R
Project Name
Stevens Residence
Building Type m Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
2124/2010
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area ft
New Existinq Altered Removed Volume Year Built
Living Zone
Existing Living
1,502
12,016 1980
Addition
125
1,000
Totals 1251 1,502 0 0
HVAC SYSTEMS
System Name
Qty. Heatin Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
Living Zone
1 Central Furnace
78% AFUE Split Air Conditioner 12.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name
Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
Living Zone
Ducted
Ducted Attic, Ceiling Ins, vented 2.1
❑ Existing
11
13
WATER HEATING SYSTEMS
S stem Name
Qty.
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.53
n/a
n/a
Existing
MULTI -FAMILY WATER
HEATING DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E
7
E
T
o
Hot Water Piping Length
ft
o
a —
System Name
Pipe
Length
Pipe
Diameter
Insul.
Thick.
Qty.FHPw
Plenum Outside
Buried
❑
❑
❑
❑
❑
❑
❑
❑
EnergyPro 5.0 by EnergySoft
User Number: 2655
Run Code: 2010-02-22T15:19:3 ID:
Page 8 of 12
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
Stevens Residence
Date
1212412010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy -measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD,. or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116 (a)1: Doors and. windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified LI -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -613 Form.
§118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
§150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 permAnch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§150(j)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculatina sections of hot water pipes are insulated per Standards Table 150-13.
§150(j)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
Registration Number: Registration Date/Time: HERS Provider:
EnergyPro5.0 by EnergySoR User Number: 2655 RunCode: 2010-02-22715:19:32 /D: Page 9 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
Stevens Residence
1212412010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tae shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Liqhting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
Registration Number: Registration Date/Time: HERS Provider:
EnergyPro 5.0 by EnergySoR User Number: 2655 Run Code: 2010-02-22T15:19:32 /D: Page 10 of 12
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Stevens Residence
2/24/2010
§150(k)11: Permanently installed luminaires located -in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptions to §150(k)13 may be controlled by a temporary override switch which bypasses'the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
Registration Number: Registration Date/Time: HERS Provider:
EnergyPro 5.0 by EnergySoft User Number: 2655 Run Code: 2010-02-22T15:19:32 /D: Pae 11 of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Stevens Residence
Date
2/24/2010
System Name
Living Zone
Floor Area
1,627
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
COIL
CFM
Total Room Loads 1,259
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output perSystem 70,000
33,704
2,750
528
26,979
Total Output Btuh 70,000
0
Output Btuh/s ft 43.0
2,890
1,781
Cooling System
0
0
Output perSystem 48,0001
0
0 0
0
Total Output Btuh 48,000
0
2,750
0
Total Output Tons 4.0
2,890
1,781
Total Output Btuh/s ft 29.5
Total Output s ft/Ton 406.8
39,484
30,540
Air System
CFM perSystem
1,300
HVAC EQUIPMENT SELECTION
Airflow cfm
1,300
Existing HVAC 40,328
0
70,000
Airflow cfm/s ft
0.80
Airflow cfm/Ton
325.0
Outside Air %
0.0%
Total Adjusted System Output 40,328
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
0
Aug 3 PM
70,000
Outside Air cfm/s ft 0.00
I Jan 1 AM
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF 69 OF
Q
Outside Air
0 cfm Supply Fan
1,300 cfm
69 OF
69 OF 119 OF
Heating Coil
118 OF
ROOM M
70 OF
COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak
112 / 78 OF 80161
Outside Air
0 cfm
80161 OF
OF 80 / 62 OF 51 / 49 OF
�
Supply Fan Cooling Coil 53 / 50 OF
1,300 cfm 12=1
36.7% � ROOM
1-0
78161 OF
EnergyPro 5.0 by EnergySoft
User Number: 2655 RunCode: 2010-02-22715:19:32 ID:
Page 12of 12