87-216 (SFD)Building 7
Address
Owner \
P.O. BOX 1504 APPLICATION ONLY
78-105 CALLE ESTADO
VKJa, S LA QUINTA, CALIFORNIA 92253
.. r,% % -+
Address �J �J� '7
City Zip Tel.
� /�,- Q\J I V k -v -x 3Li 3 - z(,7/
Contractor
(---, , /�f_= L/&)0 ��ws
Address /
City
/000/.h
BY:
ZipTel..
9Z2_71,,
-
State Lic.
& Classif.
L7// �J / r -7
GO
City
Lic. #
Arch., Engr.,
No. Dw. /
Units
New ❑ Add ❑
Designer
/-/09
-7-
INSPECTOR
Address
Date Permit
Validated by:
I Tel.
— z a "',-1'")--23 t1.
City y� Zip State
�A Q0 r �� Gq ZZt73 Lic. #
�1 LICENSED CONTRACTO 'S DECLARATION
I hereby affirm thtat I am licensed under pfovisions of Chapter 9 (commencing with Section
7000) of Divisron 3 b`the Business and P/rofessions Code, and y license is in f f ye and
effect. � \ Z / i7 %L-714. /
I hereby affirm that I am exempt from the Contractor's License Law for the following
reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a
permit to construct, after, improve, demolish, or repair any structure, prior to its Issuance also
requires the applicant for such permit to rile a signed statement that he Is licensed pursuant to
the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of
Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis
for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).
O I, as owner of the property, or my employees with wages as their sole compensation, will
do the work, and the structure is not Intended or offered for sale. (Sec. 7044, Buisness and
Professions Code: The Contractor's License Law does not apply to an owner of property who
builds or Improves thereon and who does such work himself or through his own employees,
provided that such improvements are not intended or offered for sale. If, however, the building
or Improvement is sold within one year of completion, the owner -builder will have the burden
of proving that he did not build or improve for the purpose of sale.)
❑ I, as owner of the property, am exclusively contracting with licensed contractors to con-
struct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law
does not apply to an owner of proporty•who builds or Improves thereon, and who contracts for
such projects with a contractor(s) licensed pursuant to the Contractor's License Law.)
❑ 1 am exempt under Sec. B. & P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm that I have a certificate of consent to self -insure, or a certificate of
Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.)
Policy No.Company
❑ Copy is filed with the city. ❑ Certified copy is hereby furnished.
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed If the permit Is for one hundred dollars ($100) valuation
or less.)
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any manner so as to become subject to the Workers' Compensation
laws of California.
Date Owner
NOTICE TO APPLICANT. It, after making this Certificate of Exemption you should become
subject to the Workers' Compensation provisions of the Labor Code, you must forthwith
comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
Ihereby affirm that there is a construction lending agency for the performance of the
work for which this permit is issued. (Sec. 3097, Civil Code.)
Lender's 'Name
Lender's Address
This is a building permit when properly filled out, signed and validated, and Is subject to
expiration if work thereunder is suspended for 180 days.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives -of this city to enter the above-
mentioned property for inspection purposes.
Signature of applicant Date
Mailing Address
City, State, Zip
BUILDING DIVISION
BUILDING: TYPE CONST. OCC. GRP.
A.P. Number "77 Ll- / 3 Q Z d
Legal Description ��, - 9 U l �� 44- Z ��
Project Description -.<,I
ZONE:
BY:
Minimum Setback Distances:
Front Setback from Center Line
Sq. Ft. p
Size a Z
No. /
Stories /
No. Dw. /
Units
New ❑ Add ❑
Alter ❑ Repair ❑ Demolition ❑
FINAL DATE
INSPECTOR
Issued by:
Date Permit
Validated by:
Validation:
Estimated Valuation
3 9VF
PERMIT
AMOUNT
Plan Chk. Dep.
Plan Chk. Bal.
Const.
Mech.
Electrical
Plumbing
/�7• 00
S.M.I.
zrs
Grading
e2O ,
Driveway Enc.
ao -A:%>
Infrastructure
D 5-8
P14nel.5 }w
QttiS-� i 4�Gf�9t
i 7-�-R7 4
10 LASH i I U
l iL 1 .: CJ. Vol
TOTAL
f a
REMARKS
�, I'leR ve 0
ZONE:
BY:
Minimum Setback Distances:
Front Setback from Center Line
Rear Setback from Rear Prop. Line
Side Street Setback from Center Line
Side Setback from Property Line
FINAL DATE
INSPECTOR
Issued by:
Date Permit
Validated by:
Validation:
CONSTRUCTION ESTIMATE
NO. ELECTRICAL FEES
NO. PLUMBING-F.f,&S
1ST FL. SO. FT. ® $
UNITS
SLAB GRADE
2ND FL. SQ. FT.
BONDING
YARD SPKLR SYSTEM
STORAGE TANK
MOBILEHOME SVC.
BAR SINK
POR. SQ. FT. ®
DUCT WORK
ROCK STORAGE
GAR. SQ. FT. ®
POWER OUTLET
ROOF DRAINS
HEATING (FINAL)
OTHER APPJEOUIP.
DRAINAGE PIPING
CAR P. I SQ. FT.
TEMP. POLE
WALL SQ. FT.
GROUT
DRINKING FOUNTAIN
SQ FT ®
FINAL INSP.
URINAL
ESTIMATED CONSTRUCTION VALUATION $
WATER SYSTEM
WATER PIPING
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
FINAL INSP.
WATER SOFTENER
VENT SYSTEM FAN EVAP.COOL HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE DRYER
GARBAGE DISPOSAL
FURNACE UNIT WALL FLOOR SUSPENDED
'
LAUNDRY TRAY
AIR HANDLING UNIT CFM
KITCHEN SINK
ABSORPTION SYSTEM. B.T.U.TEMP
USE PERMIT SVC
WATER CLOSET
COMPRESSOR HP
POLE, TEMIPERM
LAVATORY
HEATING SYSTEM FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER B.T.U.
SQ. FT. ® c
BATH TUB
GAR. FIREWALL
SQ. FT. @ c
WATER HEATER
MAX. HEATER OUTPUT, B.T.U.
SQ. FT. RESID ® 11/4 c
IPL.CK.FEE
SEWAGE DISPOSAL
MESH
SQ.FT.GAR ® 3/ac
HOUSE SEWER
INSULATION/SOUND
GAS PIPING
PERMIT FEE
FINISH GRADING
PERMIT FEE
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
CONST. FEE ELECT. FEESMI
FEE PLUMB. FEE
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ -Plus-x$-=$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
REMARKS:
'
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR. FIREWALL
LATHING
MESH
INSULATION/SOUND
FINISH GRADING
FINAL INSPECTION
CERT. OCC.
FENCE FINAL
INSPECTOR'S SIGNATURESIINITIALS
GARDEN WALL FINAL
dya•73
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
CONSTRUCTION ESTIMATE
UNDERGROUND
NO. ELECTRICAL FEES
NO. PLUMBING FEES
1ST FL.
SO. FT. O $ O
UNITS
r
HEATING (ROUGH)
STORAGE TANK
FORMS
2ND FL.
SO. FT. «
DUCT WORK
ROCK STORAGE
FOUND. REINF.
YARD SPKLR SYSTEM
—
HEATING (FINAL)
SO. FT.
=" d S
MOBILEHOME SVC.
TEMP. POLE
BAR SINK
L
POR.
GAR. ,23
«
SO. FT. « I(. --5-0
SERVICE
POWER OUTLET
ROOF DRAINS
WATER SYSTEM
CAR P.
SO. FT. «
_$
LUMBER GR.
DRAINAGE PIPING
FRAMING
WALL r
, SO. FT. ®
r�
70 C/
DRINKING FOUNTAIN
REMARKS:
SO. FT. did
URINAL
FIRE ZONE ROOFING
ESTIMATED CONSTRUCTION VALUATION $
G
3 /
FIREPLACE
WATER PIPING
SPARK ARRESTOR
GAR FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT OCC.
Fj. L FINAL
NOTE: Not to be used as property tax valuation
FLOOR DRAIN
MECHANICAL FEES
WATER SOFTENER
VENT SYSTEM FAN EVAP.000L HOOD
SIGN
WASH ER(AUTO)(DISH)
APPLIANCE
DRYER
GARBAGE DISPOSAL
G�
FURNACE UNIT
WALL FLOOR SUSPENDED
LAUNDRY TRAY
—
AIR HANDLING UNIT
CFM
KITCHEN SINK
—
ABSORPTION SYSTEM
B.T.U.
TEMP USE PERMIT SVC
WATER CLOSET
COMPRESSOR
HP
O
POLE, TEM/PERM
/0
LAVATORY
A.,
HEATING SYSTEM
FORCED GRAVITY
AMPERES SERV ENT
SHOWER
BOILER
B.T.U.
SO. FT. ® c
BATH TUB
SO. FT. @ c
WATER HEATER
S
MAX. HEATER OUTPUT, B.T.U.
SO. FT. RESID ® 11/4 c/
J 3l7
SEWAGE DISPOSAL
3 v
SO.FT.GAR ® 3/4c
HOUSE SEWER
GAS PIPING
PERMIT FEE
ID
PERMIT FEE
/�
PERMIT FEE
DBL
TOTAL FEES
MICRO FEE
MECH.FEE
PL.CK.FEE
CONST. FEE
ELECT. FEE
SMI FEE
PLUMB. FEE
3�•ao
s�.s�z
oo
dya•73
STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR
SETBACK
GROUND PLUMBING
UNDERGROUND
A.C. UNIT
COLL. AREA
SLAB GRADE
ROUGH PLUMB.
BONDING
r
HEATING (ROUGH)
STORAGE TANK
FORMS
SEWER OR SEPTIC TANK
ROUGH WIRING
DUCT WORK
ROCK STORAGE
FOUND. REINF.
GAS (ROUGH)
METER LOOP
HEATING (FINAL)
OTHER APPJEOUIP.
REINF. STEEL
GAS (FINAL)
TEMP. POLE
GROUT
WATER HEATER
SERVICE
FINAL INSP.
BOND BEAM
WATER SYSTEM
GRADING
cu. yd.
$ plus x$
_$
LUMBER GR.
FINAL INSP.
FRAMING
FINAL INSP.
ROOFING
REMARKS:
VENTILATION
FIRE ZONE ROOFING
FIREPLACE
SPARK ARRESTOR
GAR FIREWALL
LATHING
MESH
INSULATIONISOUND
FINISH GRADING
FINAL INSPECTION
CERT OCC.
Fj. L FINAL
QA�EN WALL FINAL
SIGNATURESIINITIALS
of ,
°" R t✓� OFFICE OF E. LEON SPAUGY
tl QCOMMISSIONER
AGRICULTURM
s AL COMISSIONER
JAMES 0. WALLACE
O �. •,J ' v AND ASS:S,A.N1 COMMISSIONER
'� jjj���^^^} WEIGHTS -& MEASURES CLEMENT BE\VENISTE
SEALER
C 49- 613 Hwy 86, Suite B- 12
��,,,,,,e•'� 'Coachella, CA 92236
Mq Y q t 8gll 619-342-8291
DATE f 2— 2 9- 8 '7 CASE NO. 8 7 2 S / 2 2 9 A
DEVEMPER' S NAME: Cc
ADDRESS: P. Q. jgd X g O i
2 L=ATd C A 2 7,K
TELEPHONE: ((/9) 3 V 3- 2� 7�
Dear Developer: S Y — ySS S 3— 6 6s
104(A.
k
After reviewing your landscaping plans, all plant material listed is not in
violation of quarantine laws governing the Coachella Valley. If substitutions
do occur and they differ from plant material listed, this office must be notified
immediately.
Thank you for protecting and preserving the Coachella Valley's pest -free environment.
Agricultural Commis ioner's Office
cc: Indio and Riverside Office
�`31 p►J b��
PROJECT DATA SUMMARY
owner
�;A c,
project
System [ype
Form 1
Checked by
date
documentation author date
SITE INFORMATION
' Z�
°F.
Heating Degree Day (from Appendix C) ..
HDD
1 —
day
Outside Design Temperature (from Appendix C or Appendix G) ......................
Tow
2
°F
PROPOSED BUILDING ENVELOPE INFORMATION
Gross Floor Area if Low -Rise (from Calculations) ............................................
At
3
ft2
Gross Wall Area if High -Rise (from Calculations) ............................................
Aw
4
ft2
Designed Glazing Area (from Calculations).......................................................
A9
5 ZI Z
ft2
Basic Glazing Area 06%of Line 3 if low-rise or 46% of Line 4 if high-rise)........
Abg
6
f12
Description ofcAsssembly
P��t=
Glazing '
Ug1
7 `
Btu/Ihr•ft2•°FI
-
Ug2
8
Btu/ (hr.ft2 •°F)
Ug3
9
Btu/ (hr .ft2 •°F)
Wall 1 ,
Uw,
10 �
Btu/(h►•ft2•°F)
Uw2
11
Btu/ (hr •ft2 •OF)
Uw3
12
Btu/ (hr •ft2 •OF)
Uw4
13
Btu/ (hr .ft2 •°F)
Ceiling/Roof G�-- vi o 0,C>
Ucl
14 `Q Z L�
Btu/ (hr. ft2 •
°F)
Uc2
15
Btu/ (hr•ft2•OF)
Floor
Un
16
Btu/ (hr.ft2 •°F)
Ut2
17
Btu/ (hr .ft2 •°F)
PROPOSED SPACE HEATING SYSTEM (Chapter 7)
Gas Furnace
,
Building Design Hourly Heat Loss (from Form 2) .....................................
cin
18
Btu/hr
Maximum Allowed Bonnet Capacity. 1.5 x Line 18 ...............................................
19
Btu/hr
Proposed Furnace
Make
Model Description
Rated Bonnet Capacity
Electric Resistance Alone
Electric Resistance Life Cycle Cost (from Form 5) ....................................
sLCCe
20
$
Lowest Life Cycle Cost of the Other Systems (from Form 51 ...................
sLCC lowest 21
$
Non-Depletable Energy w/Electric Resistance Beck -Up
Percentage of Annual Heat Loss Met by Non-Depletable Energy
Source (from Calculations)...............................................................................
22
%
Heat Pump
Percentage of Annual Heat Loss Met by Electric Resistance
(from Calculations)............................................................................................
23
%
PROPOSED WATER HEATING SYSTEM INFORMATION (Chapter 8)
Electric Resistance Atone
Electric Resistance Life Cycle Cost (from Form 6) ..............................0..
wLCCe
24
$
Lowest Life Cycle Cost of the Other Systems (from Form 6) ...................
wLCCbwe t 25
$
PROPOSED SWIMMING POOL HEATING SYSTEM INFORMATION (Chapter 9)
Solar Life Cycle Cost (from Form 7)...............................................................
pLCCs
26
$
Natural Gas Life Cycle Cost (from Form 7) ......................................................
pLCCng
27
$
HOURLY AND ANNUAL
BUILDING HEAT LOSS RATE
Chedc One: Proposed Design
Standard Design -
FA #,N,
esign
FAQ NL`( Qi �'�►
owner protect
project location Sys em type
documentation author date
Form 2R
(8/81)
Enforcement Agency Use Only
ouI ding permit numoer
CneCXOd by
SITE INFORMATION C` llZ.�
Heating Oagree Oav (from Appendix) . .......... .. .. . HDD , °
F• day
Outside Design Temperature (from Appendix) ................. Taw 1 °F
Outside January Mean Temperature (from Appendix) . . . . .. .. . . .. . TJan °F
to
PROPOSED BUILDING ENVELOPE INFORMATION
Average U
Gross Floor Area (from plans) ...... ................ .... .
Af
ft2
Gross Well Area (from plans) .................. .. .......
Aw
Graph 4
ft2
Designed Glazing Area (from plans) .........
Ag
Z\Z_
ftz
Basic Glazing Area 06% of Af if low-rise or 40% of Aw if high-rise) .. .. ...Abe
X
ft2
HOURLY HEAT LOSS
DESIGN TEMPERATURE DIFFERENCE T
For All Assemblies Other Than The Three Below . ..70°F — °F n 0Th 1 ?°F
Toy,,, from above
For Insulated Floor Over Vented Unheated Space .......... Line 1 -2 w&Thi 2 °F
For Uninsulated Floor Over Vented Unheated Space........ Lina 2 — 5°F .&Thu 3 °F
For Slab -on Ground Floors ........... 70°F — °F - &Ths 4 ' °F
Tian from above
CONDUCTIVE HEAT LOSS
Average U
Area, ft2 or
of Atfambly,
or F2 from
&T hourly heat
1Oescriptlon of Atsamoly
Length, ft
Graph 4
from above loss�jQ
L4
2-1-2—
"1 etu/hr
Glazing
X
X--
STS 21 \ Off; w �.�
1��
a
X L44
wall
X•
X
X m
Cai)ing/Roof� �- `-1 i -i X O 1 X Z3
Floor X X =
otherk?', - M eT� � 4 X I C2 j1/ ' 3 2- �P
volume Subtotal S ! atu/hr
Sum o the above Q
/10 Q_ 1151
INFILTRATION ...... 1 �[�� ft2 x ft XX 3' 'F • 6
Al from above weignted from aTh from
Average Table 3-7 Una 2 1:7 `��
Calling FNignt
Subtotal 7 line • tine to to/hr
DUCT HEAT LOSS (Enter 0 if there are no ducts) .................. OAS x Line 7
TOTAL HOURLY HEAT LOSS,Qj. 9 --S1Sa S
to/hr
Inc • line
ANNUAL HEAT LOSS, OL
. �JII
F day/yr X Btu/hr X X 24 hr/day + F 10 Btu/yr
HOa Hourly Heat Lou C from Ll Tn from
from above tram Line 9 Tapia 3-9 Line 1
Es
7DOZ-5 14 y
O ►
y�
'M "., \,-
S
ZL Z
C-O-DLA%.�CA� �—() d>
3113
`1' PROPOSED CONSTRUCTION ASSEMBLY
� BUILDING ENVELOPE COMPLIANCE
Form 3
(NR -8/81)
Check one and write In construction
assembly number below (e.g. Wall -1,
Roof -2, etc.)
19 Wall- L
0 a1I-
0 Roof -
0 Floor-
Ltst of Construction Components R -Value
.�S
2.
3. ��� X2`1 w� ► � ��
4.
Sketch of Construction Assembly
Framing type:
If wood complete the following
and adjust construction assembly
for framing:
Size: ? ' X
.Spacing- 1 O.C..
Indicate area, weight of
construction assembly, -and
appropriate factors below:
Wail: Area
ft2
Weight
Ib/ft3
MCF
TDeq
Roof: Area
ft2
Weight
lb/ft3
Mc
Ac
Floor: Area
ft2
(raised only)
5.
6.
7.
8.
Outside Surface Air Flim
Cooling Heathy
Inside Surface Air Film
cooling Heating
Total Thermal Resistance (R_T) '� y?j
Cooling Heating
IJ -Value 64AT)
Cooling Heating
Note: Total RT and U -Value must be adjusted for the effect
of framing when appropriate.
PROPOSED CONSTRUCTION ASSEMBLY
BUILDING ENVELOPE COMPLIANCE
Check one and write In construction
assembly number below (e.g. Wall -1,
Root -2, etc.)
0 Wall -
0 all-
® Roof -
0 Floor -
r
Form 3
(NR -8/81)
List of Construction Components R -Value
2.
3.1.0� �R ��' 38.0
5.
6.
7.
8.
Sketch of Construction Assembly
W�p
Framing type: S
Outside Surface Air Film
Coating
Heating
If wood complete the following
Inside Surface Air Elim
Form 3
(NR -8/81)
List of Construction Components R -Value
2.
3.1.0� �R ��' 38.0
5.
6.
7.
8.
Sketch of Construction Assembly
W�p
Framing type: S
Outside Surface Air Film
Coating
Heating
If wood complete the following
Inside Surface Air Elim
and adjust construction assembly
for framing:Q
Cooling—Heating
Size: Z" X
Total Thermal Resistance (RT)
Spacing '.=.�_� O.C..
Cooling
Heating
U -Value (WRTZ
,_
Indicate area, weight of
Cooling
Heating-'
construction assembly, • and
appropriate factors below:
Well: Area ft2
Weight � Ib/ft3
Note: Total RT and U. -Value must be
adjusted for the effect
of framing when appropriate.
MCF
TDeq
Roof: Area ft2
Weight Ib/ft3
MC
Ac
Floor: Area ft2
(raised only)
BUILDING DESIGN AND EQUIPMENT SUMMARY
Project title climate zone
project address
lproject owner
- � Z\ -pt'�
documentation autnor date
connallance method (presCridtive or oerformance. describe)
Form 2
page 1 of 2
Plan Check/Permit number
cnecked by
Cate
Enforcement Agency Use Only
BU(LD(NG
EHYELOFE oesic- .4
Description of Item Dimension
1 10( s<
Total Floor Area
fts
Z� U
1. Floor.-
Slab Perimeter, Type 1
F2
ft
' Aft
In— G
gsi,ed, Type 1 T Ez —
ft.
Type 2
2. Ceiling:
Type 1 �$
) ��y VL'A'�"1 '� Z�7Cp
fts
Type 2
ft=.
2 `
�-VA 3�3�
3 Wall:
Type t
fta
Type 2
ft'
✓ 4. Glazing:
West, Type 1 y^ �—
�la�.i �. y �—C' y, gC(
fts
ype 2
rType D U
e
�� �'�
fts
North, 1
Y.
ft'
Type 2
East, Type 1 �� tel.
y.
A� L Z•'2rp %
ftZ
fts
Type 2
South, Type 1 �l'
^ z -2 t % �3
ft:
Type 2
r
ft=
Skylight, Type 1
-SC
ft,
Type 2
C
fts
' S. Shading Coefficient. West P��
C `'"' _ S ! �� ��'
Sc
-6Z
S z, North t!
tt
r'
U� •
Ir !► Zf
SC
East
South ►t
y.�
►� 2.1 y,,�1 S'
Sc
SC
6. Horizontal South Overhang
ns�` 1 3'
ft
.7. Movable
Insulation
:
fts
8. Infiltration Control
G 9. Thermal Masi Type 1 ���� ��� g _�.g �, Q fts
_ \ Type 2 1 •Ze . L' NG � g fts
M Z Ttv�1 (o Type 3 _R HC l iG fts
tJ.
Ttq Type 4 _ K _HL tic fts
Type 5 _.,R ______w _mc fts
W 4Z
1ltAQ
1/83 — 420 — CEC \
284-66 (2/83—
Points
0
+
WA
Point Total This Page .
I
a
tar
1 pis
PEI
• _1
ES12 MODEL — DOWN-FLO
WITH FIELD INSTALLED CPR12 COIL
ERIES ELECTRIC FURNACES
E12 UP-FLO S DOWN-FLO — HORIZONTAL
13,000 to 102,400 Btuh Electric Heating Capacity
Add -On Cooling — 1-1/2 thru 5 Nominal Tons
nft
ES12 MODEL — HORIZONTAL
WITH FIELD INSTALLED CPS12 COIL
ENGINEERING DATA
HEATING UNITS
ELECTRIC
Page 11
July 1, 1983
Supersedes 9-1-82
E12 MODEL — UP-FLO
WITH FIELD INSTALLED CP12 COIL
Multi -Position Line Of Electric Furnaces Provide High Efficiency Performance And Installation Flexibility
The Lennox E12 and ES12 electric furnaces are designed for multi -position
installation in a basement, utility room, alcove, closet, crawlspace or
attic. Versatile units are applicable to heating only, heating -cooling or heat
pump applications. Several models are available in varying sizes with a wide
range of heating and cooling capacities. E12Q2 and E12Q3 models are for
up-flo applications only. The E12Q4 and E12Q5 series models are applicable
to either up-flo or down-flo installation. The ES12Q2, ES12Q3 and ES12Q4
series can be installed in the horizontal or down-flo position and the ES12Q5
models in the horizontal only.
The optional field additive "slide -in" coil installs internal to the cabinet (up
stream from the blower and electric heat elements) and is specially
matched to the unit for efficient air delivery and maximum capacity. For
up-flo applications optional return air cabinets are available for installation
on either side of the unit.
The cabinets are trim and attractive appearing with a durable electro -bonded
paint finish. Removable front panels provide complete service access to
cabinet interior. Variable speed direct drive blowers have sufficient capacity
to handle cooling air volume requirements. Hammock style fiberglass air
filters are furnished on E12 up-flo models only. Nichrome heating elements
give long service life and efficient heating operation. Factory installed cir-
cuit breakers are accessible external to the cabinet. Optional accessories
available include thermostat, return air cabinets, down-flo additive base,
outdoor thermostat and filter kits.
Units have been tested and rated according to Department of Energy (DOE)
test procedurbs and Federal Trade Commission (FTC) labeling regulations
in the Lennox Research Laboratory. Furnaces are U.L. listed. In addition,
units and components within are bonded for grounding to meet safety
standards for servicing required by UL and NEC. Blower performance data
is from unit tests conducted in the Lennox Laboratory air test chamber.
Each unit is test operated at the factory and shipped assembled (except
for the DX coil) with all controls mounted and prewired. The installer has
only to make the necessary field duct and electrical connections.
Typical Applications
Down -Flo Installation
Horizontal Installation
With Electronic Air Cleaner
And Hunudfier
NOTE — Specifications, Ratings and Dimensions subject to change without notice.
0
ij I L.: I•
Up-Flo Installation
With Return Air Cabinet
Inc es
ES12Q5
HORIZONTAL MODELS
�21-518 314 I 33� 314
• 1-118 I j ELECTRICAL INLETS
3-118 4-518 I 4 [� 1-118
Illp 13 718 AIR gG 19-318—
WELECTRICAIR
20-314 FLOW / BLOWER 1 I 23
SUPPLY _ ; / 20-314 RETURN
AIR �
OPENING HEAT , OPENING
ELEMENTS
1-118 A L U
TERMINAL STRIP 1-118
(Low Voltage)
OUTLET END FRONT VIEW INLET END
CH16-51FF
HORIZONTAL COIL
3/4 r-12 i�3/4 34
2
I
AIR 2 30 2
FLOW
NOTE — Air flow right to left as shown. 9 LIQUID LINE y5
Do not reverse. OPENINGS
SAME BOTH 21
9-5/gel SUCTION SIDES
I L—mi L L
INE
—Q
��101
4
MAIN L \AU LIIX ARY
DRAIN 2-7/8 5 DRAIN
CH16-65V
HORIZONTAL COIL
—42-1/2 10 21-1/4 —s{ � 3/4
11-7/16 19.5/8 11-7/16
23 LIQUID LINE 3 AIR
21 SUPPLY Ie
AIR 4.1/2 I / VAPOR FLOW
OPENING LINE
4-1/4 •®
1"7/8 CONDENSATE
2-1/4 DRAINS
OUTLET SIDE 4-1/4
NOTE — Air flow right to left as shown.
Do not reverse.
FRONT VIEW
ES12Q5 UNIT WITH
CH16-51FF COIL
�� •Transition must have a 6-1/2 inch straight
section from coil before'transitioning.
2
1-118
2-9/16
ro iD
35-7/8LD
in
17-7/8 RETURN
AIR
OPENING
2-9/16
INLET SIDE
ES12Q5 UNIT WITH
CH16-65V COIL
—17—
C
k
E12 SERIES SPECIFICATIONS J
Model No.
E7202-05
E12Q2-10
E12Q2-15
E12Q3-05
E12Q3-10
E12Q3-15
E12Q3-20
E12Q4-10
E12Q4-15
E12Q4-20
E17..424-25
E12Q5-15
E12Q5-20
E12Q5-25
E12Q5-30
Blower wheel nominal diam. x width (in.)
9 x 7
10 x 8
10 x 8
12 x 12
Blower motor hp
1/4
1/3
1/2
3/4
Up -Flo
Models Only
I Net free filter area (sq. ft.)
5.3
6.3
7.8
8.7
I Filter cut size (in.) 30 x 26 x 1 40 x 26 x 1 44 x 26 x 1
50 x 26 x 1
Tons of cooling that can be added
1-1/2 or 3
2-1/2 or 3
3,3-1/2 or 4
4 or 5
Shipping weight (lbs.)
121
127
160
192
Number of packages in shipment
1
1
1
1
Electrical characteristics
E12Q5-20
208-240v/60hz/1 phase
100%
tOptional Return Air
Cabinet (Up -Flo only)
Model No.
100%
RA10-16-49
RA10-16-53
100%
Shipping weight (lbs.) 54 56
LB-51349CA
tOptional Additive Coils
Model No.
Up -Flo
CP12-26V
CP12-31V, CP12-41V
CP12.46V, CP12-51V I
CP12-65V
Down -Flo ---- --- CPR12-46V, CPR12-51V
CPR12-65V
tDown-Flo Additive Base (Optional)
-
----
LB -346958C
LB-34695BD
tFilter Kit (Optional) Down -Flo Models Only
----
*LB-51349CA
tMust be ordered extra.
-2 kits are required for down-flo applications.
E12 SERIES ELECTRIC HEAT RATINGS
Model Number
tOutput Btuh
tA.F.U.E.
E12Q2-05
16,000
100%
E12Q2-10
31,000
100%
E12Q2-15
45,000
100%
E12Q3-05
16,000
100%
E12Q3-10
31,000
100%
E12Q3-15
46,000
100%
E1203-20 1
61,000
100%
E12Q4-10
31,000
100%
E12Q4-15
46,000
100%
E12Q4-20
61,000
100%
E1204-25
75.000
100%
E12Q5-15
46,000
100%
E12Q5-20
62,D00
100%
E12Q5-25
75,000
100%
E12Q5-30
91,000
100%
tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to
FTC labeling regulations.
ES12 SERIES SPECIFICATIONS
Model No.
ES12Q2-05
ES12Q2-10
ES12Q2-15
ES12Q3-05
ES12Q3-10
ES12Q3-15
ES12Q3-20
ES12Q4.05
ES12Q4-10
ES12Q4-15
ES12Q4-20
ES12415-15
ES12Q5-20
Blower wheel nominal diam. x width (in.)
- 9 x 7
9 x 7
10 x 8
12 x 9
Blower motor hp
1/4
1/3
1/3
3/4
Tons of cooling that can be added
1-1/2 or 3
2-1/2
3 or 3-1/2
4 or 5
Shipping weight (lbs.)
121
131
140
116
Number of packages in shipment
1
1
1
1
Electrical characteristics
46,000
208-240v/60hz/1 phase
ES1204-20
tOptional Additive Coils
Model No.
Horizontal
CPS12-26V
CPS12-31V
CPS12-41/46V
CH16-51FF or CH16-65V
I Down -Flo CPR12-26V CPR12-31V CPR12-41V
----
tDown-Flo Additive Base (Optional)
LB-34695BA
LB -3469568
LB-34695BB
iFilter Kit (Optional)
LB-51349CA
Must be ordered extra.
ES12 SERIES ELECTRIC HEAT RATINGS
Model Number
tOut ut Btuh
tA.F.U.E.
ES12Q2-05
15,000
98.8%
ES12O2-10
30,000
98.8%
ES12Q2-15
47,000
98.8%
ES12O3-05
16,000
99.0%
ES12O3-10
31,000
99.0%
ES12O3-15
45.000
99.0%
ES12O3-20
63,000
99.0%
ES1204-05
16,000
99.0%
ES1204-10
31,000
99.0%
ES1204-15
46,000
99.0%
ES1204-20
64,000
99.0%
ES1205-15
46,000 1
99.3%
ES1205-20
65,000 1
99.3%
tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to
FTC labeling regulations.
—13—
4LFffff&W18)
l
1
I ENGINEERING DATA
HEAT PUMPS
HP16 SERIES
MATCHED REMOTE
HEAT PUMP OUTDOOR UNITS
SYSTEMS
*18,700 to 56,000 Btuh Cooling Capacity
Page 11
Duly 1, 11
*19,900 to. 61,000 Btuh Heating Capacity
Supersedes 9-1-82
*ARI Standard 240 Certifed Ratings
CEIngGEtp YRLiOKr
NMEM Y4ED YYRN n�ORI, ' ,
. COErMMaMi �5 USIED r • .. •i
s'r,+„o,,aa • 'Eq nom` `'•
Reliability, Economy and Outstanding Efficiency for Year
Round Operation are Featured in Line Of HP16 Series Heat Pumps
The Lennox HP16 series heat pump outdoor units consist of seven models
ranging from 1-1 /2 thru 5 tons. This family of energy efficient outdoor units
have SEER'S of up to 9.8 with a cooling capacity range of 18,700 to 56,000
Btuh and COP ratings of up to 3.1 with heating capacities of 19,900 to 61,000
Btuh. A variety of matching up-flo, down-flo and horizontal blower powered
indoor units, with optional supplemental electric heat, provide selective sizing
and installation versatility. For complete data on indoor units see individual
bulletins. Several refrigerant line sets are available in various lengths, see
line kit table for selection. Line sets are optional and must be ordered extra.
The HP16 cabinet is heavy gauge galvanized steel with a durable baked -on
enamel paint finish. Special paint process protects cabinet against all kinds
of weather. Design of cabinet with louvered inlet air panels and horizontal
air discharge protects fan, fan motor, compressor and other internal com-
�nents from the weather. Heavy duty base support channels elevate unit
dDove mounting surface. Dual outdoor coils provide extra large surface area
for highest heat transfer. Coils are protected by rugged steel guards.
Automatic defrost control system operates only when required. Compressor
crankcase heater and heating -cooling thermostat with emergency heat sub-
base and warning lights are furnished as standard.
Outdoor units are test operated at the factory to insure proper operation
and are shipped ready for installation. Installer has only to locate unit and
make refrigerant line and electrical connections to complete installation.
Typical Applications
.y
NOTE — Specifications, Ratings and Dimensions subject to change without notice.
SELECTOR
*Sound Rating Number in accordance with ARI Standard 270.
tRated in accordance with ARI Standard 240 and DOE; At 450 cfm (maximum) indoor air volume per ton of cooling capacity.
Cooling Ratings - 95°F outdoor air temperature and 80OF db/67°F wb entering indoor cod air.
High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 702F db entering indoor coil air.
Low Temperature Heating Ratings - 17"F db/151F wb outdoor air temperature and 70OF db entering indoor coil air.
'Heating Seasonal Performance Factor.
*Requires field installed check and Expansion Valve Kit (LB -347928D). Must be ordered extra.
-13-
tARI Standard 240 Ratings
c
Lennox Indoor Unit Used
Lennox
'5
High
Low
Total Unit Watts
Outdoor Unit
Model No.
Cool.
Temp.
emp.7Cooring
ra,
:6.5
�
SEER
EER
High
Low
Cap.
Htg.
Htg.
Btuh/
Btu/
Down -Flo
Horizontal
*ARI Std.
Btuh
Cap.
Cap.Watt
WattHtg.
emp.HSPFC.O.P.
emp.
C.O.P.Up-Flo
270 SRN (bels)
Htg.Btuh
8tuh
Phase
3 Phase
O
"
CP12-26V
CPR12-26V
18,700
20,600
11,000
2140
9.30
----
2030
7.20
2.95
1604
2.00
31%
---
HP16-211V
/E12Q2
/ES12Q2
(7.6)
CPS12-26V
19,100
19,900
11,000
2140
9.40
--
1955
7.20
3.00
1585
2.00
26%
-
--
_
/ES12Q2
CP12-26V
CPR12-26V
�-
22,600
25,000
14,000
2630
9.00
---
2525
7.40
2.90
2060
2.00
24%
--
/E12Q2
/ES12Q2
H P16-261 V
CPS 12-26V
23,400
25,600
14,500
2650
9.30
----
2475
7.30
3.00
2095
2.05
25%
----
---
(7.81
/ES12Q2
CP12-31V
CPR12-31V----
24,400
26,000
14,000
2723
9.60
----
2478
7.50.
3.10
2004
2.05
18%
/E12Q3
/ES1203
CP12-31 V
28,800
32,000
18,100
3400
9.10
----
3139
7.40
3.00
2599
2.05
22%
----
----
/E1203
CPR12-31V
CPS12-31V
29,000
131,800
17,800
3380
9.10
----
3119
7.40
3.00
2579
2.05
22%
----
HP76-311V
/ES12Q3
/ES12Q3
(8.0)
CP12-41V
30,200
32,200
18,200
3410
9.25
---
3035
7.50
3.10
2650
2.10
22%
----
----
/E12Q3
CPR12-41V
30,200
32,200
18,100
3445
9.10
----
3070
7.50
3.05
2549
2.05
220%
----
----
/ES12Q4
CPR12-41V
/ES12Q4
CPS12-41/46V
35,200
35,800
19,600
4115
9.10
8.60
3636
7.55
2.90-
2928
1.95
23%
---
HP16-411V
CPR12-46V
/ES12Q4
(Use SEER)
/E12Q4
HP16-413V
CP12-41V
(Use EER)
35,200
35,800
19,600
4053
9.30
8.70
3584
7.55
2.95
2875
2.00
23%
----
---
(8.2) •
/ E12Q3
CP12-46V
35,000
36,000
19,800
4140
9.00
8.50
3661
7.60
2.90
2953
1.95
23%
----
/E1204
42,000
38,000
21,000
4347
1 9.00
8.85
4250
6.70
2.60
3180
1.95
21%
----
----
•CH16-51FF
H P 16-461 V
41,500
42,500
26,000
5048
8.70
8.20
4488
7.60
2.75
3696
2.05
24%
___
CPR12-46V
CPS12-41/46V
(Use SEER) :
HP16-413V
/E12Q4
/ES1204
(Use EER)
CP12-46V
(8.2) �j►
41,500
42,500
26,200
5093
8.70
8.10
4533
7.60
2.75
3741
2.05
24%
---
-
-
/E12Q4
HP16-511V;
46,500
49,500
29,500
5570
9.00
8.35
4363
8.05
3.00
3835
2.30
22%
---
----
•CH16-51FF
(Use SEER)
CP12-51V
CPR12-51V
HP16-513V
45,500
50,000
30,200
5614
8.80
8.10
4939
7.85
2.95
3988
2.20
20%
-
(Use EER)
/E12Q4
/E12Q4
46,500
49,500
29,800
5570
9.00
8.304872
8.05
3.00
3844
2.30
20%
-
----
CH16-65V
(8.2) `'
H P16-651 V
55,500
59,500
34,400
6789
8.15
8.20
6005
7.40
2.90
4715
2.15
22%
-
---
CH 16-65V
(Use SEER►
CP12 65V
CPR12-65V
HP16-653V
(Use EER)
55,500
62,500
37,600
7177
8.05
7.75
6340
7.50
2.90
5032
2.20
23%
-
(8.2)
/E1205
/E12Q5
*Sound Rating Number in accordance with ARI Standard 270.
tRated in accordance with ARI Standard 240 and DOE; At 450 cfm (maximum) indoor air volume per ton of cooling capacity.
Cooling Ratings - 95°F outdoor air temperature and 80OF db/67°F wb entering indoor cod air.
High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 702F db entering indoor coil air.
Low Temperature Heating Ratings - 17"F db/151F wb outdoor air temperature and 70OF db entering indoor coil air.
'Heating Seasonal Performance Factor.
*Requires field installed check and Expansion Valve Kit (LB -347928D). Must be ordered extra.
-13-
�.� RATINGS
f NOTE - To determine Sensible Capacity, Leaving Wet Bulb and Dry Bulb temperatures not shown
' in the cooling table see Miscellaneous Engineering Data section, Page 9.
HP16-651V4MV COOLING CAPACITY WITH CP12-65V OR CPR12-65V INDOOR COIL UNIT
Enter.
Wet
Bulb
(OF)
Total
Air
Vol.
(cfm)
Outdoor Air Temperature Entering Outdoor Coil (°F)
85
25 1 5 11
105
115
Total
Cool
Cap.
(Btuh)
Comp.
Motor
Watts
Input
Sensible
To Total
Ratio lb (O
Dry Bulb (° 4
76 80 84
Total
Cool
Cap
(Btuh)
Comp.
Motor
Watts
Input
Sensible
To Total
Ratio
Total
Cool
Ca
(Btuh)
Comp.
Motor
Watts
Input
Sensible
To Total
Ratio lb (O
Dry Bulb (° 4
76 80 84
Total
Cool
Cap.
(Btuh)
Comp.
Motor
Watts
Input
Sensible
To Total
Ratio
lb (O
Dry Bulb 1° 4
76 80 84
lb (O
Dry Bulb (°
4
76 80 84
Motor
2000-
58,400
5060
.80 1 .92 11.00
55,600
5380
.82 .95 1.00
52,900
5680
.84 .98 1.00
50,100
5950
.87 1.00 1.00
63
2250
59,600
5110
.83 .97 1.00
56,800
5440
.85 .99 1.00
54,000
5750
.88 1.00 1.00
51,800
6050
.91 1.00 1.00
76,200
2500
60,600
5170
.87 1.00 1.00
58,000
5510
.89 1.00 1.00
55,500
5830
.92 1.00 1.00
53,000.
6130
.95 1.00 1.00
3155
2000
62,200
5240
.62 .74 .86
59,200
5560
.63 .76 .88
56,200
5870
.65 .78 .91
53,300
6140
.66 .80 .94
67
2250
63,200
5280
.64 .77 .90
60,100
5610
.66 .80 .93
57,000
5910
.67 .82 .96
54,100
6190
.69 .84 .99
2500 1164,100
5320
.67 .81 1 .94 1160,900
5650
.68 .83 .97
57,800
5950
.70 .85 1.00
54,800
6230
.72 .88 1.00
2000
66,600
5430
.46 .58 1 .69
163,400
5760
.47 .59 .71
60.200
6080
.47 .60 .72
157,200
6360
.48 .61 .74
71
225^
67,500
5470
.47 .60 .72
64,200
5800
.48 .61 .74 1161,000
6120
.49 .62 .76
57,900
6390
.49 .64 .78
2500
68,300
5500 1
.48 .62 .75
64,900
5840
.49 .63 .77
61,700
6150
1 .50 .65 .79
58,500
6430
.51 .66 .82
NOTE - All values are gross capacities and do not include indoor coil blower motor heat deduction.
HP16-651V-MV HEAT PUMP OUTDOOR UNIT HEATING CAPACITY
NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur.
HP16-651V453V HEATING PERFORMANCE
at 2250 cfm Indoor Coil Air Volume
(CP12-65V & CPR12-65V)
*Outdoor
Temperature
(Degree F)
Compressor
Motor Watts
Input
Air Temperature Entering Outdoor Coil (°F)
65 45
25 1 5 11
-15
Indoor
Indoor Coil
Unit
Air Volume
Total
Comp. Total
Comp.
Total
Comp. Total
Comp.
Total
Comp.
Model
(cfm)
Heating
Motor Heating
Motor
Heating
Motor Heating
Motor
Heating
Motor
No.
70F db
Capacity
Watts Capacity
Watts
Capacity
Watts Capacity
Watts
Capacity
Watts
36,800
15
(Btuh)
Input (Btuh)
Input
(Btuh)
Input (Btuh)
Input
(Btuh)
Input
CP12-65V
CA12-65V
2000
76,200
5615 1 59,400
4745
41,800
3830 29,800
3175
18,700
2835
2250
77,200
5490 60,100 1
4670
42,300
3770 11 30,200
3155
19,000
2815
2500
78,100
5385 1 60,8001
4610
42,800
3720 11 30,500
3135
19,200
2795
NOTE - Heating capacities include the effect of defrost cycles in the temperature range where they occur.
HP16-651V453V HEATING PERFORMANCE
at 2250 cfm Indoor Coil Air Volume
(CP12-65V & CPR12-65V)
*Outdoor
Temperature
(Degree F)
Compressor
Motor Watts
Input
Total
Output
(Btuh)
65
5490
77,200
60
5290
73,100
55
5095
69,000
50
4885
64,500
47
4760
'62,000
45
4670
60,100
40
4450
55,700
35
4215
51,000
30
3975
46,500
25
3770
42,300
20
3560
38,700
17
3510
36,800
15
3330
35,300
10
3265
32,800
5
3155
30,200
0
3070
27,700
-5
3005
25,100
-10
2915
22,300
-15
2815
19,000
-20
2710
16,200
'Outdoor temperature at 70% relative humidity. Indoor temperature at 70°.
-14p-
7
EHEI-SW
SPECIFICATIONS
.�J r
Model'No.
HP16-211V
HP16-261V
HP16-311V
HP16411V
HP16413V
HP16.461V
HP16463V
HP16-511V
HP16-513V
HP16-651V
HP16-653V
Outdoor
Coil
Net face area (sq. ft.)
6.67
6.67
8.00
10.11
10.11
12.9
12.9
Tube diam. (in.) 3/8 3/8 3/8 3/8 3/8 3/8
3/8
No. of rows 3 3 3 3 3 3
4
Fins per inch 15 15 15 15 15 15
15
Outdoor
Fan
Diameter (in.)
18
20
20
22
24
24
24
No. of blades 4 4 4 4 4 4
4
Motor hp 1/10 1/5 1/5 1/4 1/3 1/3
1/3
Cfm (factory setting) 1750 2400 2900 3100 3800 3600
3800
Rpm (factory setting) 1085 1115 1040 830 830 840
810
Watts (factory setting) 135 205 305 285 395 370
425
Refrigerant -22 (charge furnished)
7 lbs. 14 oz.
8 lbs. 7 oz.
9 lbs. 4 oz.
11 lbs. 0 oz.
12 lbs. 4 oz.
14 lbs. 4 oz.
19 lbs. 8 oz.
Liquid line connection (sweat)
3/8
3/8
3/8
3/8
3/8
3/8
1/2
Vapor line connection (sweat)
5/8
5/8
3/4
314
7/8
7/8
1-118
Shipping weight (lbs.)
245
250
275
322
333
403
411
Number of packages
1
1
1
1
1
1
1
ELECTRICAL DATA
Model Number
HP16-211V
HP16-261V
HP16-311V
HP16-411V
HP16-413V
Line voltage data
208/230V
60hz/lph.
208/230V
60hz/1ph.
208/230V
60hz/1ph.
208/230V
60hz/lph.
208/230V
60hz/3ph
Compressor
Rated load amps
9.7.
11.5
14.7
17.9
12.5
Power factor 1 .95 .96 .95 .94
.89
Locked rotor amps 48.0 54.0 65.0 83.5
66.0
Outdoor Coil
Fan Motor
Full load amps
0.70
1.3
1.5
2.0
2.0
Locked rotor amps 1.0 3.5 3.5 4.0
4.0
Rec.maximum fuse or circuit breaker size (amps)
20
25
30
40
30
'Minimum circuit ampacity
12.8
15.7
19.8
24.4
17.6
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
ELECTRICAL DATA
Model Number
HP16-461V
HP16.463V
HP16-511V
HP16-513V
HP16-651V
HP16-653V
Line voltage data
208/230V
60hz/tph.
208/230V
60hz/3ph
208/230V
60hz/tph
208/230V
60hz/3ph
208/230V
60hz/lph
208/230V
60hz/3ph
Compressor
Rated load amps
21.5
13.7
25.6
15.9
28.0
19.0
Power factor .96 .88 .96 .90 .97
.90
Locked rotor amps 1 95.4 82.0 116.0 92.0 142.0
107.0
Outdoor Coil
Fan Motor
Full load amps
2.5
2.5
2.5
2.5
2.5
'2.5
jLocked rotor amps 5.5 5.5 5.5 5.5 5.5
5.5
Rec.maximum fuse or circuit breaker size (amps)
50
30
60
35
60
45
-*Minimum circuit ampacity
29.4
19.6
34.5
22.4
37.5
26.3
a
*Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
FIELD WIRING
-------, .-------, BB r-----------,
LENNOX rDISCONNECTr IDISCONNECT! J t LENNOX r A - Two or Three wire power (see Electrical Table) )
THERMOSTAT SWITCH i I SWITCH OPTIONAL I
(fumished) (BY HERS): j (BY OTHERS) t I AUXILIARY B - Two or Three wire power (size to heater capacity)
a-- _ .J a------_� I ELECTRIC I i
HEATER UNIT t C - Two wire power (size to indoor coil blower motor)
E A i OPTIONAL D - Two wire low voltage (18 ga. minimum)
OUTDOOR
iTHERMOSTATI
�-----_-J F p E -Eight wire low voltage (18 ga. minimum) with Electric Heat
- Ten wire low voltage with Optional Outdoor Thermostat
T G F - Four wire low voltage (18 a. minimum)
(DISCONNECT I 9 9
OUTDOOR rSWITCH
UNIT j (BY OTHERS) I G -Three Wire low voltage (18 ga. minimum)
a------- G LENNOX
INDOOR UNIT - Field wiring not furnished -
NOTE - All wiring to conform to NEC and local electrical codes.