Loading...
10-0705 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 10700000705 Property Address: 79125 BIG HORN TR APN: 772-030-011-18 -25429 - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 20000 Tiht 4 4 Q" Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT -------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my Lic is in full force and effect. Lice se'c7s: B ��)) License 2 Date: /V ontractor: 112'11OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: J 1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and /I the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 1 am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the 'work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: P1 K LQPERMIT Owner: ANDERSON ROBERT C Contractor: CV ELITE BUILDERS INC PO BOX 5686 LA QUINTA, CA 92253 (760)837-0079 Lic. No.: 591025 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 9/03/10 t%EP 03 270F111 LA QUIWTA ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self:insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is ' I issued. y I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor 7' Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 238004121 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 700 of the Labor Code I shall forthwith comply w' fans 'ions. ate: 0 pplicant: WARNING: F ILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter uponure eabove-mentioned pro for inspection purposes. Date:!V�Si at // (Applicant or Agent). Application Number . . . . . 10-00000705 ------ Structure Information EXISTING 3226 SFD ----- Other struct info . . . . . CODE EDITION 2007/08 ENERGY # BEDROOMS .00 FLOOD ZONE NO GARAGE SQ FTG .00 PATIO SQ FTG .00 1ST FLOOR SQUARE FOOTAGE 110.00 ---------------------------------------------------------------------------- 2ND FLOOR SQUARE FOOTAGE .00 Permit . . BUILDING PERMIT Additional desc . Permit Fee . . . . 207.00 Plan Check Fee 134.55 Issue Date . . . . Valuation . . . . .20000 Expiration Date 3/02/11 Qty Unit Charge Per Extension BASE FEE 45.00 18.00 9.0000 ------------------------------------------------------------------------'---- THOU BLDG.2,001-25,000 162.00 Permit . . . ELECT -.ADD/ALT/REM Additional desc . . Permit Fee . . . . 18.85 Plan Check Fee 4.71 Issue Date . . . . Valuation . . . . 0 Expiration Date 3/02/11 Qty Unit Charge Per Extension BASE FEE 15.00 110.00 .0350 ----------------------------------------------7----------------------------- ELEC NEW RES - 1 OR 2 FAMILY 3.85 Permit . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/02/11 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments 110 SQ FT. LIVING ADDITION TO EXISTING SFD. TYPE V -B CONSTR. 2007 CODES.2008 ENERGY. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 LQPERMIT LQPERMIT Application Number . . . . . 10-00000705 ------------------------ Other Fees . . . . --------------------------------------------------- . . . . . ENERGY REVIEW'FEE 13.46 STRONG MOTION (SMI) - RES 2.00 Fee summary ----------------- Charged ---------- Paid ---------- ---------- Credited ----------- Due Permit Fee Total 245.35 .00 .00 245.35 Plan Check Total 144.14 .00 .00 144.14 Other Fee Total 16.46 .00 .00 16.46 Grand Total 405.95 .00 .00. 405.95 LQPERMIT Bin # City Of La Quints Building a Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: Owner's Name: A. P. N Address: 9j2 5 Lg/ Cfo �ti' L al Description: 'ty, ST, Zip: L C� Contractor: Telephone: .ssr. Address: ProjfctDescription: A )z:) fi1D1j City, ST, Zip: Telephone: tate Lic. # : City Lic. 4, esiper. ^f9 Address: ��p D City., ST, Zip: " Telephone: 7 G 0 6/�(� V ; Construction Type: —,AJ Occupancy: State Lic. #: ¢'' Project type (circle one): New 4M Alter Repair Demo Name of Contact Person: 5 Sq. Ft : # Stories: #Units: Telephone # of Contact Person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets to Plan Check submitted 10 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calca. Called Contact Person g'� Plan Check Balance. Title 24 Cates. ?j Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready for correction e k Electrical Subcontactor List Called Contact Person Z , Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Pians resubmitted Grading IN HOUSE:- 'rd Review, ready for corrections/issue Developer Impact Fee f Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue • School Fees • UN Total Permit Fees �o . CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES r RANCHO MIRAGE d Date 8/19/10 La Quinta, CA 92253 INDIAN WELLS d PALM DESERT y No. 30799 (760) 771-8515 1 QUINTA 1Q1INDIO y� 0 Owner Robert & Martha Anderson APN # 776-030-010 Address 79125 Big Hom Trail Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Residential Addition Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79125 Big Horn Trail 110 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 110 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - David Jackson Check No. Name on the check Telephone Funding Exempt By Dr. Sharon P. McGehee Superintendent Fee collected /exempted by/S�Xon Pgpilvrey Payment Recd Signature $0.00 -p�wer/Wider J NOTICE: Pursuant to Government Code Section 66020(d)f), this fAll serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the Ndeo which the building or installation permit for this project is issued, or from the date on which those amolfnts are paid to the District(s) or to another pu c entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting BUILDING ENERGY ANALYSIS REPORT PROJECT: Robert & Marty Anderson Addition 79125 Big Horn Trail APN# 776-030-010 La Quinta, CA 92253 Project Designer: Dual Designs 760-771-3626 Report Prepared by: David Jackson EQS, Inc. 42335 Washington St. #F-330 Palm Desert, CA 92211 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTI N DATE pl VIM jr- LD,�� AUG 19 2010 Job Number: Date: 8/16/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is I authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 Room Load Summary 14 EnewPro 5.1 by Er -%,W Job Number. ID: User Number 5862 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF-IR Project Name Robert & Marty Anderson Addition Building Type ® Single Family O Addition Alone o Multi Family ® Existing+ Addition/Alteration Date 8/1612010 Project Address 79125 Big Horn Trail APN# 776-030-010 California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 3, 290 Addih"on 110 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavi Features see Part 2 of 5 Status wall Wood Framed R-21 2,215 Existing Door Opaque Door None 48 Existing Door Opaque Door Insul 24 Existing Slab Unheated Slabon-Grade None 3,180 Perim = 290' Existing Roof Wood Framed Attic R-30 3,180 Existing Wall Wood Framed R-21 96 New Slab Unheated Slab-on-Grade None 110 Perim = 12' New Roof Wood Framed Attic R-0 110 New FENESTRATION U- Exterior Orientation Area Factor SHGC Overhang Sidefins Shades Status Front (N) 83.5 0.510 0.61 none none Bug Screen Existing Left (SE) 64.0 0.510 0.61 none none Bug Screen Existing Rear (S) 225.0 0.510 0.61 none none Bug Screen Existing Rear(SW 128.0 0.510 0.61 none none Bug Screen Existing Rear (S) 24.0 0.510 0.61 none none Bug Screen New Left (E) 88.0 0.510 0.61 none none Bug Screen Existing Right (W 25.0 0.510 0.61 none none Bug Screen Existing HVAC SYSTEMS Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing 1 Central Fumaos 80% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R-Value Status HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Type Gallons Min. Eff Distribution Status Energyfto 5.1 by EnergySoff User Number. 5662 RunCode. 2010-08-13T18.-01:1 /D: Page 3 of 15 PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R Project Name Robert & Marty Anderson Addition Building Type ® Single Family ❑ Addition Alone 1 ❑ Muni Family ® Existing+ Addition/Alteration Date 8/16/2wo SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checldist These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System Existing DHW is a non-NAECA large storage gas water heater. Verify DHW details. The Existing Water Heater Existing DHW has an EF less than the Vintage Defaults. Field verification is required. The HVAC System HVAC System must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appencra R4-6 must be met. HIGH MASS Design - Verify Thermal Mass. 1,721.0 It=Exposed Slab Floor, 3.500'thick at Living Area HIGH MASS Design - Verify Thermal Mass: 178.0 ft2 Covered Slab Floor, 3.500' thick at Living Area HIGH MASS Design -Verify Thermal Mass: 110.0 ftZ Exposed Slab Floor, 3.500'thick at Living Area -Addition The HVAC System HVAC System must serve only Sleeping Areas. The non losable area between zones cannot exceed 40 sf and each zone must be controlled with a separate themrostat In addition the air flow requirements and fan watt draw requirements in Residential Appendix R4-6 must be HIGH MASS Design - Verify Thermal Mass. 234.0 ftz Exposed Slab Floor, 3.500' thick at Sleeping Area HIGH MASS Design - Verify Thermal Mass. 1,047.0 ft' Covered Slab Floor, 3.500'thick at Sleeping Area HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnergyPro 5.1 by EnemySolt User Number. 5862 RunCode: 2010.08-13T18:01:1 ID: Pace 4 of 15 PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R Project Name Building Type ® Single Family O Addition Alone Date Robert & Marty Anderson Addition o Multi Family m Existing+ Addition/Afteration 8/16/2010 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 Space Heating 6.77 4.36 2.41 Space Cooling 117.40 112.07 5.33 Fans 26.28 24.82 1.46 Domestic Hot Water 6.12 8.12 0.00 Pumps 0.00 0.00 0.00 Totals 158.57 149.37 9.20 Percent Better Than Standard: 5.8% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (N) 810 84 Fuel Available at Site: Natural Gas (E) 710 152 Raised Floor Area: o (S) 830 377 Slab on Grade Area: 3,290 (149 670 25 Average Ceiling Height: 10.0 Roof 3,290 0 Fenestration Average U-Factor: 0.51 TOTAL: 638 Average SHGC: 0.61 Fenestration/CFA Ratio: 19.4% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company EQS, Inc. 8/162010 Address 42335 Washington St. #F-3W Name David Jackson 9 Cityaateop Palm Desert CA 92211 Phone 760-674-2345 Signed Date The individual with overall design responsibility hereby certifies that the proposed building desi n represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Dual Designs David Jackson Address Name City/Statellp . Phone 760-771-3626 Signed License # Date En Pro 5.1 by EnemySoft User Number. 5862 RunCode: 201046-13718.01:1 ID: Page 5 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CFA R Project Name Robert & Marty Anderson Addition Building Type ® Single Family o Mufti Family 0 Addition Alone ® Existing+ Addition/Afteration Date 8/16/2010 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Factor Ca ' Exterior Frame Interior Frame Azm Tilt Status Joint Appendix 4 Location/Comments Wall 413 0.069 R-21 0 90 Existing 4.3.1 A6 Living Area Door 48 0.500 None 0 90 Existing 4.5.1 A4 Livirig Area Door 24 0.500 Insul 0 90 Existing 4.5.1 A3 Living Area Wall 240 0.069 R-21 90 90 Existing 4.3.1A6 LiWng Area Wall 26 0.069 R-21 135 90 Existin 4.3.1 A6 Living Area Wall 140 0.069 R-21 180 90 EcisfiR 4.3.1 A6 Living Area Wall 52 0.069 R-21 225 90 Existing 4.3.1 A6 Living Area Wag 30 0.069 R-21 270 90 Existing 4.3.1-A6 Living Area Wall 77 0.069 R-21 0 90 Removec 4.3.1 A6 Living Area Wall 64 0.069 R-21 90 90 Removec 4.3.1 A6 Living Area Wall 90 0.069 R-21 180 90 Removec 4.3.1 A6 Living Area Slab 1,721 0.730 None 0 180 Existing 4.4.7 -Al Living Area Slab 178 0.730 None 0 180 Existin 4.4.7 -Al Living Area Roof 1,899 0.031 R -V 0 0 Existing 4.2.1-A20 Living Area Wall 96 0.069 R-21 180 90 New 4.31 A6 Living Area Slab 110 0.730 None 0 180 New 4.4.7-A I Living Area FENESTRATION SURFACE DETAILS ID Type Area 1.1 -Facto r SH Azm Status Glazing Type Location/Comments 1 Window 17.5 0.510 NFRC 0.61 NFRC 0 Existing Vinyt0ear Living Area 2 Window 17.5 0.510 NFRC 0.61 NFRC 0 Existing VinyMear Living Area 3 Window 10.0 0.510 NFRC 0.61 NFRC 0 Existing Vm ar Living Area 4 Window 64.0 0.510 NFRC 0.61 NFRC 135 Existing VinyMear Living Area 5 Window 30.0 0.510 NFRC 0.61 NFRC 180 Existing VinyMear Living Area 6 Window 120.0 0.510 NFRC 0.61 NFRC 180 Existing VinyMear Living Area 7 Window 30.0 0.510 NFRC 0.61 NFRC 180 Existing VinybVear Living Area 8 Window 64.0 0.510 NFRC 0.61 NFRC 225 Existing VinyUClear Living Area 9 Window 64.0 0.510 NFRC 0.61 NFRC 225 Existing V<nybVear Living Area 10 Window 13.5 0.510 NFRC 0.61 NFRC 0 Removed VinybVear Living Area 11 Window 24.0 0.510 NFRC 0.61 NFRC 90 Removed VinybVear Living Area 12 Window 32.0 0.510 NFRC 0.61 NFRC 90 Removed VinyMear Living Area 13 Window 24.0 0.510 NFRC 0.61 NFRC 180 New Vin ear Living Area 14 Window 22.0 0.510 NFRC 0.61 NFRC 0 Existing VinyMear sleeping Area 15 Window 16.5 0.510 NFRC 0.61 NFRC 0 Existing VinWClear steeping Area 16 Window 24.0 0.510 NFRC 0. 611 NFRC 90 Existing VinybVear I sleeping Area (1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = labeled Value 2 SHGC T 116-6 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Window Exterior Shade Type SHGC Hgt Wd Ove ang Len Hgt LExt RExt Left Fin Dist Len Hgt Riciht Fn Dist Len Hgt 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Speen 0.76 4 Bug Speen 0.76 5 Bug Speen 0.76 6 Bug Speen 0.76 7 Bug Speen 0.76 8 Bug Speen 0.76 9 Bug Speen 0.76 10 Bug Speen 0.76 11 Bug Speen 0.76 12 Bug Speen 0.76 13 Bug Speen 0.76 14 _Bug Speen0.76 15 Bu Speen 0.76 16 gSaeen I[Bug 0.76 EnetgyPro 5.1 by EnemySoft User Number. 5862 RunCode: 2010-08-13T18.01:1 ID: Page 6 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF-1R Project Name Robert & Marty Anderson Addition Building Type ® Single Family o Multi Family ❑ Addition Alone ® Existing+ Addition/Alteration Date 1811612010 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area FactorYv Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Roof 110 0.031 R-30 0 0 New 4.2.1 A20 LMng Area Wall 242 0.069 R-21 0 90 Existing 4.3. f A6 sleeping Area Wall 292 0.069 R-21 90 90 Existing 4.3.1 A6 sleeping Area Wall 165 0.069 R-21 180 90 Existing 4.3.1 A6 sfeWing Area Wall 615 0.069 R 21 270 90 Existing 4.3.1 A6 sleep#ng Area Slab 234 0.730 None 0 180 Existing 4.4.7-A I sleeping Area Slab 1,047 0.730 None 0 180 Existing 4.4.7A1 sleeping Area Roof 1,281 0.031 R-30 0 0 Existing 4.2.1 A20 sleeping Area FENESTRATION SURFACE DETAILS ID Type Area U-Factor SHG Azm Status Glazing Type Location/Comments 17 Window 64.0 0.510 NFRC 0.61 NFRC 90 Existing VnyMear sleeping Area 18 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existing VinyMear sleeping Area 19 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existin Inn ear sf in Area 20 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existing VnybVear sleeping Area 21 Window 10.0 0.510 NFRC 0.61 NFRC 270 Existing VnybVear sleeping Area 22 Window 5.0 0.510 NFRC 0.61 NFRC 270 Existing VnyMear sleeping Area 23 Window 10.0 0.510 NFRC 0.61 NFRC 270 Existing VnyMear sleeping Area (1) L{-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC T 116-B = Default Table from Standards NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC Rqt Wd Ove ang Len Hgt LExt RExt Left Fin Dist Len Hgt Ftiaht Fn Dist Len I Hgt 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 EnenjyRo 5.1 by EnemySoff User Number. 5962 RunCode: 2010.08-13T18M:1 to. Pae 7 of 15 CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5 CF -IR Project Name Robert & Marty Anderson Addition Building Type ® Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 8/16/2010 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New E)dsting I Altered Removed Volume Year BuiR HVAC System Living Area 1,899 18,990 1998 Living Area -Addition 110 1,100 HVAC System Sleeping Area 1,281 12,810 1998 Totals 110 3,180 0 0 HVAC SYSTEMS System Name Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC System 1 Central Furnace 800loAFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC System 1 Central Furnace 800loAFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Coolinq Duct Location R -Value Ducts Tested? Status HVAC System Ducted Ducted Attic, Ceffing Ins, vented 4.2 ❑ Existing HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Existing DHW 1 Large Gas No Pipe Insulation 80,000 74 0.78 0.00% 0.0 Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E(ft) E m w a. Hot Water Piping Length o a — System Name Pipe Lenath Pipe Diameter Insul. Thick. Qtv. HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPm 5.1 by Ene ft User Number. 5862 RunCode: 2010-08-13T18:01:1 ID: Pace 8 of 15 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -IR Project Name Robert & Marty Anderson Addition Date IS(16)2010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measure: 116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §1180: The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent 1.1 -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§I 50 c : Minimum R-13 insulation in wood -frame wall or equivalent U -factor. *§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §150ft Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the GF -IR Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 permfinch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning,Water Heating and Plumbing stem Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1 A: Storage gas water heaters ratand with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or RA 6 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-6. §1501012: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-8 and Equation 150-A. §150(0)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 1500)3A: Insulation is protected from damage, including that due to sunlight moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §150014: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnewPro 5.1 b EnewSoft User Number. 5662 RunCode: 20104)8-13T18:01:17 /D: Page 9 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R Project Name Date Robert & Marty Anderson Addition 1811612010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cones. §150(o): All dwelling units shall meet the requirements of ANSVASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light §114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-0 and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 500% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode: 2010-08-13T18:01:17 ID. Page 10 of 15 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Robert 8 Marty Anderson Addition 18116)2010 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time dock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130,131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of §119. EnergyPm 5.1 by EnergyWt User Number. 5862 RunCode: 2010-08-13718:01:17 ID: Page 11 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Robert & Marty Anderson Addition Date 8/16/2010 System Name HVAC System Floor Area 2,009 ENGINEERING CHECKS SYSTEM LOAD Number of System 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,399 32,319 Return Vented Lighting 0 Return Air Ducts 2,741 Return Fan o Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,741 TOTAL SYSTEM LOAD 1 37,8001 COIL HTG. Latent CFM 3,019 996 0 0 3.0191 PEAK Heating em Sensible Outpout r System 55,000 27,641 Total Output h 55,000 Output gtuti/ 27.4 1,964 Cooling m 0 Output per System 56,000 0 Total Output h 56,000 0 Total output ons 4.7 1,964 Total Output h/ 27.9 Total Output on 430.5 31,569 Air System CFIM per System 2,000 HVAC EQUIPMENT SELECTION Airflow (cfm) 2,000 E)dsting 5 Ton Unit 46,332 Total Adjusted System Output 1 46,332 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1,965 55,000 1,965 55,000 Aug 3 PM f Jan 1 AM Airflow chn/ 1.00 Airflow cknrron 428.6 Outside Air % 0.0% Outside Air (O"ft) 0.00 Note: values above given at ARI conditions I HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 260F Outside Air 0 cfm 690F 69 °F 970F 970F Heating Col Supply Fan 960F 2,000 cfni ROOM 70 °F rl COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cool' Peals 112/78°F Outside Air 0 cfm 79/63°F 79/63°F 55/54°F 55/54°F Cooling Col Supply Fan 2,000 cdm 42.6% 56 / 54 OF i ROOM 78/63°F EnergyPro 5.1 by EnergySoft User Number. 5862 RunCodw 2010-08-13T18.*1:17 /D: Page 12 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Date Robert & Marty Anderson Addition 8/16/2010 System Name Floor Area HVAC System 1,281 ENGINEERING CHECKS SYSTEM LOAD Number of Svstems 1 1 COIL COOLING PEAK COIL HTG. PEAK Heating CFM Total Room Loads 889 Return Vented Lighting Return Air Ducts Return Fan Ventilation F 0 Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD Sensible 20,525 0 1,740 0 0 0 1,740 1 24,005 Latent CFM 1,70.5 916 01-0 1,705 Sensible Outpurt per system 31,200 18,530 Total n 31.200 Output Stuh/ 24.4 1,316 Cooling m 0 Output per system 35,100 0 Total Output h 35,100 0 Total Output ons 2.9 1,316 Total Output tuh/ 27.4 Total Output on 437.9 21,162 Air System CFM per System 1257 HVAC EQUIPMENT SELECTION Allow (cfm) 1,257 Existing3Ton 29,114 1,133 31,200 Airflow dnV 0.98 Airflow chn/Ton 429.7 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design motions) I TIME OF SYSTEM PEAK 1 29,114 1,133 1 31,200 Aug 3 PM Jan 1 AM Outside Air cfm/ 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 69 OF Outside Air 0 cfm Supply Fan 1,257 ctm 69 OF 69 OF 90 OF Heating Col rn 89 OF ROOM 70 OF 112/78°F 79/63°F 79/63°F 55/54°F Outside Air 0 dm Supply Fan Ming Coil 56 / 54 OF 1,257 cfm 42.5% I ROOM 79/63°F 78/63°F rl En&WPm 5.1 by EnergySoft User Number. 5862 RonCo*. 2010.08-13T16.. f: f7 /D: Page 13 of 15 ROOM LOAD SUMMARY Project Name Date Robert & Marty Anderson Addition 8/16/2010 System Name Floor Area HVAC System 2,009 ROOM LOAD SUMMARY I I I ROOM COOLING PEAK 1 COIL COOLING PEAK I COIL FTG. PEAK I Zone Name I Room Name Muff. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible LMng Area LivingArua 1 1,230 28,431 2,142 1,230 28,431 2142 936 25,972 Living Area-Aditon 1 I INI 3,8881 6781 INI 3,W81 8781 601 1,669 PAGE TOTAL TOTAL ' Total includes 1,39,9 32,319 3,019 996 27,641 1,399 32,319 3,Oi9 996 27,641 I ROOM LOAD SUMMARY Project Name Date Robert & Marty Anderson Addition 8/16/2010 System Name Roor Area HVAC Svstem 1,281 I I I ROOM COOLING PEAK I COIL COOLING PEAK I COIL FfTG. PEAK Zone Name I Room Name I Muff. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible stewing Area I Sleeping Area I 1 1 8991 20,525 1,70-51 8891 20,52,51 1,7051 9161 18,530 I ' Total includes ventilation toad for zonal PAGE TOTAL TOTAL• 889 20,5251 1,704 9161 18,530 889 20,525 1,70 918 18,530