10-0705 (AR)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
10700000705
Property Address:
79125 BIG HORN TR
APN:
772-030-011-18 -25429 -
Application description:
ADDITION - RESIDENTIAL
Property Zoning:
LOW DENSITY RESIDENTIAL
Application valuation:
20000
Tiht 4 4 Q"
Applicant: Architect or Engineer:
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
--------------------------------------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my Lic is in full force and effect.
Lice se'c7s: B ��)) License 2
Date: /V ontractor: 112'11OWNER-BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 70001 of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: J
1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and /I
the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
(_ 1 1 am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
'work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address: P1 K
LQPERMIT
Owner:
ANDERSON ROBERT C
Contractor:
CV ELITE BUILDERS INC
PO BOX 5686
LA QUINTA, CA 92253
(760)837-0079
Lic. No.: 591025
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 9/03/10
t%EP 03 270F111
LA QUIWTA
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self:insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
' I issued.
y I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
7' Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 238004121
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
700 of the Labor Code I shall forthwith comply w' fans 'ions.
ate: 0 pplicant:
WARNING: F ILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter uponure eabove-mentioned pro for inspection purposes.
Date:!V�Si at
// (Applicant or Agent).
Application Number . . . . . 10-00000705
------ Structure Information EXISTING 3226 SFD
-----
Other struct info . .
. . . CODE EDITION
2007/08 ENERGY
# BEDROOMS
.00
FLOOD ZONE
NO
GARAGE SQ FTG
.00
PATIO SQ FTG
.00
1ST FLOOR SQUARE FOOTAGE
110.00
----------------------------------------------------------------------------
2ND FLOOR SQUARE FOOTAGE
.00
Permit . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
207.00 Plan Check Fee
134.55
Issue Date . . . .
Valuation . .
. . .20000
Expiration Date
3/02/11
Qty Unit Charge
Per
Extension
BASE FEE
45.00
18.00 9.0000
------------------------------------------------------------------------'----
THOU BLDG.2,001-25,000
162.00
Permit . . .
ELECT -.ADD/ALT/REM
Additional desc . .
Permit Fee . . . .
18.85 Plan Check Fee
4.71
Issue Date . . . .
Valuation . .
. . 0
Expiration Date
3/02/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
110.00 .0350
----------------------------------------------7-----------------------------
ELEC NEW RES - 1 OR 2 FAMILY 3.85
Permit . .
MECHANICAL
Additional desc .
Permit Fee . . . .
19.50 Plan Check Fee
4.88
Issue Date . . . .
Valuation . .
. . 0
Expiration Date . .
3/02/11
Qty Unit Charge
Per
Extension
BASE FEE
15.00
1.00 4.5000
EA MECH VENT INST/ DUCT ALT
4.50
----------------------------------------------------------------------------
Special Notes and Comments
110 SQ FT. LIVING ADDITION
TO EXISTING
SFD. TYPE V -B CONSTR.
2007 CODES.2008
ENERGY.
----------------------------------------------------------------------------
Other Fees . . . . .
. . . . BLDG STDS ADMIN (SB1473)
1.00
LQPERMIT
LQPERMIT
Application Number
. . . . .
10-00000705
------------------------
Other Fees . . . .
---------------------------------------------------
. . . . .
ENERGY REVIEW'FEE
13.46
STRONG MOTION
(SMI) - RES
2.00
Fee summary
-----------------
Charged
----------
Paid
---------- ----------
Credited
-----------
Due
Permit Fee Total
245.35
.00
.00
245.35
Plan Check Total
144.14
.00
.00
144.14
Other Fee Total
16.46
.00
.00
16.46
Grand Total
405.95
.00
.00.
405.95
LQPERMIT
Bin #
City Of La Quints
Building a Safety Division
P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
Project Address: Owner's Name:
A. P. N Address: 9j2 5 Lg/ Cfo �ti' L
al Description: 'ty, ST, Zip: L C�
Contractor: Telephone: .ssr.
Address: ProjfctDescription: A )z:) fi1D1j
City, ST, Zip:
Telephone:
tate Lic. # : City Lic. 4,
esiper. ^f9
Address: ��p D
City., ST, Zip: "
Telephone: 7 G 0 6/�(� V ; Construction Type: —,AJ Occupancy:
State Lic. #: ¢'' Project type (circle one): New 4M Alter Repair Demo
Name of Contact Person: 5
Sq. Ft :
# Stories: #Units:
Telephone # of Contact Person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS LINE
N
Submittal
Req'd
Recd
TRACKING
PERMIT FEES
Plan Sets
to
Plan Check submitted
10
Item Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss Calca.
Called Contact Person
g'�
Plan Check Balance.
Title 24 Cates.
?j
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for correction
e
k
Electrical
Subcontactor List
Called Contact Person
Z ,
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Pians resubmitted
Grading
IN HOUSE:-
'rd Review, ready for corrections/issue
Developer Impact Fee f
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
•
School Fees
•
UN
Total Permit Fees
�o .
CERTIFICATE OF COMPLIANCE
Desert Sands Unified School District
47950 Dune Palms Road Q BERMUDA DUNES r
RANCHO MIRAGE d
Date 8/19/10 La Quinta, CA 92253 INDIAN WELLS
d PALM DESERT y
No. 30799 (760) 771-8515 1 QUINTA
1Q1INDIO y�
0
Owner
Robert & Martha Anderson
APN # 776-030-010
Address
79125 Big Hom Trail
Jurisdiction La Quinta
City
La Quinta Zip
Permit #
Tract #
No. of Units 1
Type
Residential Addition
Lot # No. Street
S.F.
Lot # No. Street S.F.
Unit 1
79125 Big Horn Trail
110 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiostwalkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
Education Code Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 110 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Exempt - David Jackson Check No.
Name on the check Telephone
Funding Exempt
By Dr. Sharon P. McGehee
Superintendent
Fee collected /exempted by/S�Xon Pgpilvrey Payment Recd
Signature
$0.00
-p�wer/Wider J
NOTICE: Pursuant to Government Code Section 66020(d)f), this fAll serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the Ndeo which the building or installation permit for this project is issued, or from the date on
which those amolfnts are paid to the District(s) or to another pu c entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Robert & Marty Anderson Addition
79125 Big Horn Trail APN# 776-030-010
La Quinta, CA 92253
Project Designer:
Dual Designs
760-771-3626
Report Prepared by:
David Jackson
EQS, Inc.
42335 Washington St. #F-330
Palm Desert, CA 92211
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTI N
DATE pl VIM
jr- LD,��
AUG 19 2010
Job Number:
Date:
8/16/2010
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is I
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 9
HVAC System Heating and Cooling Loads Summary 12
Room Load Summary 14
EnewPro 5.1 by Er -%,W Job Number. ID: User Number 5862
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF-IR
Project Name
Robert & Marty Anderson Addition
Building Type ® Single Family O Addition Alone
o Multi Family ® Existing+ Addition/Alteration
Date
8/1612010
Project Address
79125 Big Horn Trail APN# 776-030-010
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
3, 290
Addih"on
110
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes ❑ No HERS Measures -- If Yes, A CF-4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area Special
Cavi Features see Part 2 of 5 Status
wall Wood Framed R-21 2,215 Existing
Door Opaque Door None 48 Existing
Door Opaque Door Insul 24 Existing
Slab Unheated Slabon-Grade None 3,180 Perim = 290' Existing
Roof Wood Framed Attic R-30 3,180 Existing
Wall Wood Framed R-21 96 New
Slab Unheated Slab-on-Grade None 110 Perim = 12' New
Roof Wood Framed Attic R-0 110 New
FENESTRATION U- Exterior
Orientation Area Factor SHGC Overhang Sidefins Shades Status
Front (N) 83.5 0.510 0.61 none none Bug Screen Existing
Left (SE) 64.0 0.510 0.61 none none Bug Screen Existing
Rear (S) 225.0 0.510 0.61 none none Bug Screen Existing
Rear(SW 128.0 0.510 0.61 none none Bug Screen Existing
Rear (S) 24.0 0.510 0.61 none none Bug Screen New
Left (E) 88.0 0.510 0.61 none none Bug Screen Existing
Right (W 25.0 0.510 0.61 none none Bug Screen Existing
HVAC SYSTEMS
Heating Min. Eff
Cooling Min. Eff Thermostat Status
1 Central Furnace 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
1 Central Fumaos 80% AFUE
Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R-Value Status
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2 Existing
HVAC System Ducted
Ducted Attic, Ceiling Ins, vented 4.2 Existing
WATER HEATING
Type Gallons Min. Eff Distribution Status
Energyfto 5.1 by EnergySoff User Number. 5662
RunCode. 2010-08-13T18.-01:1 /D:
Page 3 of 15
PERFORMANCE CERTIFICATE: Residential Part 2 of 5 CF -1 R
Project Name
Robert & Marty Anderson Addition
Building Type ® Single Family ❑ Addition Alone
1 ❑ Muni Family ® Existing+ Addition/Alteration
Date
8/16/2wo
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checldist These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The DHW System Existing DHW is a non-NAECA large storage gas water heater. Verify DHW details.
The Existing Water Heater Existing DHW has an EF less than the Vintage Defaults. Field verification is required.
The HVAC System HVAC System must serve only Living Areas. The non -closable area between zones cannot exceed 40 sf and each zone must be
controlled with a separate thermostat. In addition the air flow requirements and fan watt draw requirements in Residential Appencra R4-6 must be met.
HIGH MASS Design - Verify Thermal Mass. 1,721.0 It=Exposed Slab Floor, 3.500'thick at Living Area
HIGH MASS Design - Verify Thermal Mass: 178.0 ft2 Covered Slab Floor, 3.500' thick at Living Area
HIGH MASS Design -Verify Thermal Mass: 110.0 ftZ Exposed Slab Floor, 3.500'thick at Living Area -Addition
The HVAC System HVAC System must serve only Sleeping Areas. The non losable area between zones cannot exceed 40 sf and each zone must
be controlled with a separate themrostat In addition the air flow requirements and fan watt draw requirements in Residential Appendix R4-6 must be
HIGH MASS Design - Verify Thermal Mass. 234.0 ftz Exposed Slab Floor, 3.500' thick at Sleeping Area
HIGH MASS Design - Verify Thermal Mass. 1,047.0 ft' Covered Slab Floor, 3.500'thick at Sleeping Area
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
EnergyPro 5.1 by EnemySolt User Number. 5862 RunCode: 2010.08-13T18:01:1 ID: Pace 4 of 15
PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF-1 R
Project Name
Building Type ® Single Family O Addition Alone
Date
Robert & Marty Anderson Addition
o Multi Family m Existing+ Addition/Afteration
8/16/2010
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kBtu/ft2
Space Heating 6.77 4.36 2.41
Space Cooling 117.40 112.07 5.33
Fans 26.28 24.82 1.46
Domestic Hot Water 6.12 8.12 0.00
Pumps 0.00 0.00 0.00
Totals 158.57 149.37 9.20
Percent Better Than Standard: 5.8%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (N) 0 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (N) 810 84
Fuel Available at Site: Natural Gas (E) 710 152
Raised Floor Area: o (S) 830 377
Slab on Grade Area: 3,290 (149 670 25
Average Ceiling Height: 10.0 Roof 3,290 0
Fenestration Average U-Factor: 0.51 TOTAL: 638
Average SHGC: 0.61 Fenestration/CFA Ratio: 19.4%
REMARKS
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the
Efficiency Standards of the California Code of Regulations.
The documentation author hereby certifies that the documentation is accurate and complete.
Documentation Author
Company EQS, Inc.
8/162010
Address 42335 Washington St. #F-3W Name David Jackson 9
Cityaateop Palm Desert CA 92211 Phone 760-674-2345 Signed Date
The individual with overall design responsibility hereby certifies that the proposed building desi n represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Designer or Owner (per Business & Professions Code)
Company Dual Designs
David Jackson
Address Name
City/Statellp . Phone 760-771-3626 Signed License # Date
En Pro 5.1 by EnemySoft User Number. 5862 RunCode: 201046-13718.01:1 ID: Page 5 of 15
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CFA R
Project Name
Robert & Marty Anderson Addition
Building Type ® Single Family
o Mufti Family
0 Addition Alone
® Existing+ Addition/Afteration
Date
8/16/2010
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation
Factor Ca ' Exterior Frame Interior Frame Azm Tilt Status
Joint Appendix
4 Location/Comments
Wall
413
0.069 R-21
0
90 Existing
4.3.1 A6
Living Area
Door
48
0.500 None
0
90 Existing
4.5.1 A4
Livirig Area
Door
24
0.500 Insul
0
90 Existing
4.5.1 A3
Living Area
Wall
240
0.069 R-21
90
90 Existing
4.3.1A6
LiWng Area
Wall
26
0.069 R-21
135
90 Existin
4.3.1 A6
Living Area
Wall
140
0.069 R-21
180
90 EcisfiR
4.3.1 A6
Living Area
Wall
52
0.069 R-21
225
90 Existing
4.3.1 A6
Living Area
Wag
30
0.069 R-21
270
90 Existing
4.3.1-A6
Living Area
Wall
77
0.069 R-21
0
90 Removec
4.3.1 A6
Living Area
Wall
64
0.069 R-21
90
90 Removec
4.3.1 A6
Living Area
Wall
90
0.069 R-21
180
90 Removec
4.3.1 A6
Living Area
Slab
1,721
0.730 None
0
180 Existing
4.4.7 -Al
Living Area
Slab
178
0.730 None
0
180 Existin
4.4.7 -Al
Living Area
Roof
1,899
0.031 R -V
0
0 Existing
4.2.1-A20
Living Area
Wall
96
0.069 R-21
180
90 New
4.31 A6
Living Area
Slab
110
0.730 None
0
180 New
4.4.7-A I
Living Area
FENESTRATION SURFACE DETAILS
ID
Type Area 1.1 -Facto r SH
Azm Status
Glazing Type
Location/Comments
1
Window
17.5 0.510 NFRC 0.61 NFRC 0 Existing
Vinyt0ear
Living Area
2
Window
17.5 0.510 NFRC 0.61 NFRC 0 Existing
VinyMear
Living Area
3
Window
10.0 0.510 NFRC 0.61 NFRC 0 Existing
Vm ar
Living Area
4
Window
64.0 0.510 NFRC 0.61 NFRC 135 Existing
VinyMear
Living Area
5
Window
30.0 0.510 NFRC 0.61 NFRC 180 Existing
VinyMear
Living Area
6
Window
120.0 0.510 NFRC 0.61 NFRC 180 Existing
VinyMear
Living Area
7
Window
30.0 0.510 NFRC 0.61 NFRC 180 Existing
VinybVear
Living Area
8
Window
64.0 0.510 NFRC 0.61 NFRC 225 Existing
VinyUClear
Living Area
9
Window
64.0 0.510 NFRC 0.61 NFRC 225 Existing
V<nybVear
Living Area
10
Window
13.5 0.510 NFRC 0.61 NFRC 0 Removed VinybVear
Living Area
11
Window
24.0 0.510 NFRC 0.61 NFRC 90 Removed
VinybVear
Living Area
12
Window
32.0 0.510 NFRC 0.61 NFRC 90 Removed
VinyMear
Living Area
13
Window
24.0 0.510 NFRC 0.61 NFRC 180 New
Vin ear
Living Area
14
Window
22.0 0.510 NFRC 0.61 NFRC 0 Existing
VinyMear
sleeping Area
15
Window
16.5 0.510 NFRC 0.61 NFRC 0 Existing
VinWClear
steeping Area
16
Window
24.0 0.510 NFRC 0. 611 NFRC 90 Existing
VinybVear
I sleeping Area
(1) LI -Factor Type: 116-A = Default Table from Standards, NFRC = labeled Value
2 SHGC T 116-6 = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Window
Exterior Shade Type SHGC Hgt Wd
Ove ang
Len Hgt LExt RExt
Left Fin
Dist Len Hgt
Riciht Fn
Dist Len Hgt
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Speen
0.76
4
Bug Speen
0.76
5
Bug Speen
0.76
6
Bug Speen
0.76
7
Bug Speen
0.76
8
Bug Speen
0.76
9
Bug Speen
0.76
10
Bug Speen
0.76
11
Bug Speen
0.76
12
Bug Speen
0.76
13
Bug Speen
0.76
14
_Bug Speen0.76
15
Bu Speen
0.76
16
gSaeen
I[Bug
0.76
EnetgyPro
5.1 by EnemySoft User Number. 5862
RunCode: 2010-08-13T18.01:1
ID:
Page 6 of 15
CERTIFICATE OF COMPLIANCE: Residential
Part 4 of 5 CF-1R
Project Name
Robert & Marty Anderson Addition
Building Type ® Single Family
o Multi Family
❑ Addition Alone
® Existing+ Addition/Alteration
Date
1811612010
OPAQUE SURFACE DETAILS
Surface U- Insulation Joint Appendix
Type Area FactorYv Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments
Roof 110 0.031 R-30
0 0 New
4.2.1 A20
LMng Area
Wall 242 0.069 R-21
0 90 Existing
4.3. f A6
sleeping Area
Wall 292 0.069 R-21
90 90 Existing
4.3.1 A6
sleeping Area
Wall 165 0.069 R-21
180 90 Existing
4.3.1 A6
sfeWing Area
Wall 615 0.069 R 21
270 90 Existing
4.3.1 A6
sleep#ng Area
Slab 234 0.730 None
0 180 Existing
4.4.7-A I
sleeping Area
Slab 1,047 0.730 None
0 180 Existing
4.4.7A1
sleeping Area
Roof 1,281 0.031 R-30
0 0 Existing
4.2.1 A20
sleeping Area
FENESTRATION SURFACE DETAILS
ID Type Area U-Factor SHG
Azm Status Glazing Type
Location/Comments
17 Window 64.0 0.510 NFRC 0.61 NFRC 90 Existing VnyMear
sleeping Area
18 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existing VinyMear
sleeping Area
19 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existin Inn ear
sf in Area
20 Window 15.0 0.510 NFRC 0.61 NFRC 180 Existing VnybVear
sleeping Area
21 Window 10.0 0.510 NFRC 0.61 NFRC 270 Existing VnybVear
sleeping Area
22 Window 5.0 0.510 NFRC 0.61 NFRC 270 Existing VnyMear
sleeping Area
23 Window 10.0 0.510 NFRC 0.61 NFRC 270 Existing VnyMear
sleeping Area
(1) L{-Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC T 116-B = Default Table from Standards NFRC = Labeled Value
EXTERIOR SHADING DETAILS
Window
ID Exterior Shade Type SHGC Rqt Wd
Ove ang
Len Hgt LExt RExt
Left Fin
Dist Len Hgt
Ftiaht Fn
Dist Len I Hgt
17 Bug Screen 0.76
18 Bug Screen 0.76
19 Bug Screen 0.76
20 Bug Screen 0.76
21 Bug Screen 0.76
22 Bug Screen 0.76
23 Bug Screen 0.76
EnenjyRo 5.1 by EnemySoff User Number. 5962
RunCode: 2010.08-13T18M:1
to.
Pae 7 of 15
CERTIFICATE OF COMPLIANCE: Residential Part 5 of 5
CF -IR
Project Name
Robert & Marty Anderson Addition
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
8/16/2010
BUILDING ZONE INFORMATION
System Name
Zone Name
Floor Area
New E)dsting I Altered Removed Volume Year BuiR
HVAC System Living Area
1,899
18,990 1998
Living Area -Addition
110
1,100
HVAC System Sleeping Area
1,281
12,810 1998
Totals 110 3,180 0 0
HVAC SYSTEMS
System Name
Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
HVAC System
1 Central Furnace
800loAFUE Split Air Conditioner 13.0 SEER Setback
Existing
HVAC System
1 Central Furnace
800loAFUE Split Air Conditioner 13.0 SEER Setback
Existing
HVAC DISTRIBUTION
System Name
Heating
Duct
Coolinq Duct Location R -Value
Ducts
Tested? Status
HVAC System Ducted Ducted Attic, Ceffing Ins, vented 4.2
❑ Existing
HVAC System Ducted Ducted Attic, Ceiling Ins, vented 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy Standby
Factor Loss or
or RE Pilot
Ext.
Tank
Insul. R-
Value
Status
Existing DHW
1
Large Gas
No Pipe Insulation
80,000
74
0.78 0.00%
0.0
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
E(ft)
E
m
w a.
Hot Water Piping Length
o
a —
System Name
Pipe
Lenath
Pipe
Diameter
Insul.
Thick.
Qtv. HP
Plenum Outside Buried
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
EnemyPm 5.1 by Ene ft
User Number. 5862
RunCode: 2010-08-13T18:01:1 ID:
Pace 8 of 15
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -IR
Project Name
Robert & Marty Anderson Addition
Date
IS(16)2010
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (') below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measure:
116 a 1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§1180: The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling or equivalent 1.1 -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§I 50 c : Minimum R-13 insulation in wood -frame wall or equivalent U -factor.
*§150(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor.
§150ft Air retarding wrap is tested labeled and installed according to ASTM E1677-95(2000) when specified on the GF -IR Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0 permfinch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning,Water Heating and Plumbing stem Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve backflow prevention, pump isolation valve and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACOA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§1500)1 A: Storage gas water heaters ratand with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or RA 6 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-6.
§1501012: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-8 and Equation 150-A.
§150(0)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
1500)3A: Insulation is protected from damage, including that due to sunlight moisture equipment maintenance and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
§150014: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnewPro 5.1 b EnewSoft User Number. 5662 RunCode: 20104)8-13T18:01:17 /D: Page 9 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1R
Project Name
Date
Robert & Marty Anderson Addition
1811612010
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and retum-air duds and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cones.
§150(o): All dwelling units shall meet the requirements of ANSVASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light
§114(b)l : Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 .
Residential Lighting Measures:
§150(k)l : High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low efficacy luminaire as specified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined as specified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-0 and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans in rooms other than kitchens shall meet the applicable requirements of §150(k).
§150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 500% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet
EnergyPro 5.1 by EnergySoft User Number. 5862 RunCode: 2010-08-13T18:01:17 ID. Page 10 of 15
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
Robert 8 Marty Anderson Addition
18116)2010
§150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or bypass switch that disables the astronomical time dock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130,131 134 and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of §119.
EnergyPm 5.1 by EnergyWt User Number. 5862 RunCode: 2010-08-13718:01:17 ID: Page 11 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
Robert & Marty Anderson Addition
Date
8/16/2010
System Name
HVAC System
Floor Area
2,009
ENGINEERING CHECKS
SYSTEM LOAD
Number of System
1
COIL COOLING PEAK
CFM Sensible
Total Room Loads 1,399 32,319
Return Vented Lighting 0
Return Air Ducts 2,741
Return Fan o
Ventilation 0 0
Supply Fan 0
Supply Air Ducts 2,741
TOTAL SYSTEM LOAD 1 37,8001
COIL HTG.
Latent CFM
3,019 996
0 0
3.0191
PEAK
Heating em
Sensible
Outpout r System 55,000
27,641
Total Output h 55,000
Output gtuti/ 27.4
1,964
Cooling m
0
Output per System 56,000
0
Total Output h 56,000
0
Total output ons 4.7
1,964
Total Output h/ 27.9
Total Output on 430.5
31,569
Air System
CFIM per System
2,000
HVAC EQUIPMENT SELECTION
Airflow (cfm)
2,000
E)dsting 5 Ton Unit 46,332
Total Adjusted System Output 1 46,332
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1,965 55,000
1,965 55,000
Aug 3 PM f Jan 1 AM
Airflow chn/ 1.00
Airflow cknrron 428.6
Outside Air % 0.0%
Outside Air (O"ft) 0.00
Note: values above given at ARI conditions I
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
260F
Outside Air
0 cfm
690F
69 °F 970F 970F
Heating Col Supply Fan
960F
2,000 cfni
ROOM
70 °F
rl
COOLING SYSTEM PSYCHROMETICS
Airstream Temperatures at Time of Cool' Peals
112/78°F
Outside Air
0 cfm
79/63°F
79/63°F 55/54°F 55/54°F
Cooling Col Supply Fan
2,000 cdm
42.6%
56 / 54 OF
i ROOM
78/63°F
EnergyPro 5.1 by EnergySoft
User Number. 5862 RunCodw 2010-08-13T18.*1:17 /D:
Page 12 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name Date
Robert & Marty Anderson Addition 8/16/2010
System Name Floor Area
HVAC System 1,281
ENGINEERING CHECKS SYSTEM LOAD
Number of Svstems 1 1 COIL COOLING PEAK COIL HTG. PEAK
Heating
CFM
Total Room Loads 889
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation F 0
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
Sensible
20,525
0
1,740
0
0
0
1,740
1 24,005
Latent CFM
1,70.5 916
01-0
1,705
Sensible
Outpurt per system 31,200
18,530
Total n 31.200
Output Stuh/ 24.4
1,316
Cooling m
0
Output per system 35,100
0
Total Output h 35,100
0
Total Output ons 2.9
1,316
Total Output tuh/ 27.4
Total Output on 437.9
21,162
Air System
CFM per System
1257
HVAC EQUIPMENT SELECTION
Allow (cfm)
1,257
Existing3Ton
29,114
1,133
31,200
Airflow dnV
0.98
Airflow chn/Ton
429.7
Outside Air %
0.0%
Total Adjusted System Output
(Adjusted for Peak Design motions)
I TIME OF SYSTEM PEAK
1 29,114
1,133 1 31,200
Aug 3 PM Jan 1 AM
Outside Air cfm/ 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating
Peak
26 OF 69 OF
Outside Air
0 cfm Supply Fan
1,257 ctm
69 OF
69 OF 90 OF
Heating Col
rn
89 OF
ROOM
70 OF
112/78°F 79/63°F 79/63°F 55/54°F
Outside Air
0 dm Supply Fan Ming Coil 56 / 54 OF
1,257 cfm
42.5% I ROOM
79/63°F 78/63°F
rl
En&WPm 5.1 by EnergySoft User Number. 5862 RonCo*. 2010.08-13T16.. f: f7 /D: Page 13 of 15
ROOM LOAD SUMMARY
Project Name Date
Robert & Marty Anderson Addition 8/16/2010
System Name Floor Area
HVAC System 2,009
ROOM LOAD SUMMARY
I I I ROOM COOLING PEAK 1 COIL COOLING PEAK I COIL FTG. PEAK I
Zone Name I Room Name Muff. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible
LMng Area LivingArua 1 1,230 28,431 2,142 1,230 28,431 2142 936 25,972
Living Area-Aditon 1 I INI 3,8881 6781 INI 3,W81 8781 601 1,669
PAGE TOTAL
TOTAL '
Total includes
1,39,9
32,319
3,019
996
27,641
1,399
32,319
3,Oi9
996
27,641
I
ROOM LOAD SUMMARY
Project Name Date
Robert & Marty Anderson Addition 8/16/2010
System Name Roor Area
HVAC Svstem 1,281
I I I ROOM COOLING PEAK I COIL COOLING PEAK I COIL FfTG. PEAK
Zone Name I Room Name I Muff. I CFM I Sensible I Latent I CFM I Sensible I Latent I CFM I Sensible
stewing Area I Sleeping Area I 1 1 8991 20,525 1,70-51 8891 20,52,51 1,7051 9161 18,530
I ' Total includes ventilation toad for zonal
PAGE TOTAL
TOTAL•
889
20,5251
1,704
9161
18,530
889
20,525
1,70
918
18,530