Loading...
15278 (AR)44Q P.O. BOX 1504 Buil('ing78-495 CALLE TAMPICO � Address 44-490 lazing Star Tr. LA OUINTA, CALIFORNIA 92253 Owner Tim Smartt Address Same City Zip Tel. La Quints, CA 92253 Contractor Sriellenberger & Associates Ai lr?to iris Court Quinta, CA 7 Ip92253 Te 0--5759 State Lic. City & Classif. S $6$234 1 Lic. # 1558 Arch., Engr., Designer Address Tel. City IZip I State Lic. # LICENSED CONTRACTOR'S DECLARATION . I hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. SIGNATURE DATE OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractors License Law for the following reason: (Sec. 7031.5,Business and Professions Code: Any city or county which requires a permit to construct, after, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he. is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that. he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by 'any applicant for a permit subjects the applicant to a civil penalty of not more than rive hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will - do the work, and the structure is not intended or offered for sale. (Sec. 7044, Buisness and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or inprove for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to con- struct the project. (Sec. 7044, Business and -Professions Code: The Contractor's License Law does not apply to an, owner ofpropertywho builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec B. & P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. t CERTIFICATE OF EXEMPTION FROM - WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) valuation or less.) I certify that in the performance of thg work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. Date Owner NOTICE TO APPLICANT: If, after making this Certificate of Exemption you should become subject to the Workers' Cornpensation provisions of the Labor Code, you must forthwith comply with such provisions or this pemrit shall be deemed revoked. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 160 days.. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-. mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip No. 15278 BUILDING: TYPE CONST. OCC. GRP. A.P. Number Legal Description Project Description Gar$tje. Addition Sq. Ft. Size 160 No. No. Dw. Stories Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ r Estimated Valuation $3,136.00 I PERMIT AMOUNT Plan Chk. Dep. Plan Chk. Bal. 40.95 Const. 6T- Uta Mech. Electrical 18.20 Plumbing S.M.I. .31 Grading Driveway Enc. — Infrastructure TOTAL 122.46 REMARKS ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback from Property Line FINAL DATE INSPECTOR Issued by Validated Validatior CONSTRUCTION ESTIMATE NO. ELECTRICAL FEES NO. PLUMBINv FEES 1ST FL. SO. FT. ® $ UNITS COLL. AREA 2ND FL. SO. FT. 01 YARD SPKLR SYSTEM BONDING MOBILEHOME SVC. BAR SINK POR. SO. FT. ® SEWER OR SEPTIC TANK GAR. SO. FT. ® POWER OUTLET ROOF DRAINS FOUND. REINF. DRAINAGE PIPING CAR P. SO. FT. HEATING (FINAL) OTHER APPJEOUIP. WALL SO. FT. ® DRINKING FOUNTAIN SO. FT. ® URINAL ESTIMATED CONSTRUCTION VALUATION $ WATER PIPING NOTE: Not to be used as property tax valuation FINAL INSP. FLOOR DRAIN MECHANICAL FEES WATER SOFTENER VENT SYSTEM FAN EVAP.COOL HOOD SIGN WASHER(AUTO)(DISH) APPLIANCE DRYER GARBAGE DISPOSAL FURNACE UNIT WALL FLOOR SUSPENDED FINAL INSP. LAUNDRY TRAY AIR HANDLING UNIT CFM KITCHEN SINK ABSORPTION SYSTEM B.T.U. TEMP USE PERMIT SVC WATER CLOSET COMPRESSOR HP POLE, TEM/PERM LAVATORY HEATING SYSTEM FORCED GRAVITY AMPERES SERV ENT SHOWER BOILER B.T.U. SO. FT. ® c BATH TUB FIREPLACE SO. FT. ® c WATER HEATER MAX. HEATER OUTPUT, B.T.U. SO. FT. RESID ® 1+A c SEWAGE DISPOSAL SO.FT.GAR ® V4c HOUSE SEWER GAS PIPING PERMIT FEE PERMIT FEE PERMIT FEE DBL TOTAL FEES MICRO FEE MECH.FEE PL.CK.FEE CONST. FEE ELECT. FEE SMI FEE PLUMB. FEE STRUCTURE PLUMBING ELECTRICAL HEATING & AIR COND. SOLAR SETBACK GROUND PLUMBING UNDERGROUND A.C. UNIT COLL. AREA SLAB GRADE 01 ROUGH PLUMB. BONDING HEATING (ROUGH) STORAGE TANK FORMS SEWER OR SEPTIC TANK ROUGH WIRING DUCT WORK ROCK STORAGE FOUND. REINF. GAS (ROUGH) METER LOOP HEATING (FINAL) OTHER APPJEOUIP. REINF. STEEL GAS (FINAL) TEMP. POLE GROUT WATER HEATER SERVICE FINAL INSP. BOND BEAM WATER SYSTEM GRADING cu. yd. $ plus x$ =$ LUMBER GR. FINAL INSP. FRAMING 4- FINAL INSP. ROOFING \ I1\� REMARKS: VENTILATION FIRE ZONE ROOFING FIREPLACE SPARK ARRESTOR GAR. FIREWALL r LATHING V 5 MESH INSULATION/SOUND FINISH GRADING\, FINAL INSPECTION CERT. OCC. FENCE FINAL INSPECTOR'S SIGNATURES/INITIALS GARDEN WALL FINAL try: v �.s i � 4 � `�.::. <`•`i~�� 1 1 I � Lzl-- o �I 6I�I -� I I f=C)N-D, 10LAsJ qv-wO' 61Z,1vG- cow b'�FE NCTE-745 C7j C I 9 I �07' FOUNDATION PLAN.NOTES F 1. All.construction shall confirm to the latest applicable edition of U.B.C. Building Code and local ordinances. F 2. The 28 day strength and type of concrete shall be as follows: Slabs on grade ........... 2,000 P.S.I. Footing...................2,500 P.S.I. F 3. Reinforcing metal shall conform to: Reinforcing Steel,.ASTM A-615,Grade 60 Reinforcing Fabric.ASTM A-815 & A-82 F 4. Plumber to verify all plumbing locations, before slab is poured. F 5. All exterior patios to drain away from dwelling and top of patio slab to be minimum of 1/2" below interior top of slab. F 6. Dwelling T.O.S. min, of 6" above finish grade. F 7. Tool all exposed edges at garage and patios. F,8. All sill & plate wood in contact w/conc. shall be approved pressure treated Douglas Fir per U.B.C. 2516C. F.9. Mud sill anchor bolt spacing to be 5/8" diameter anchor bolts at 4'-0" ctrs. except at shear panels where A.B. spacing shall be per schedule on the Framing Plan. •rj1;,n ii%��'t' . "a?i:5 T..`�it=�=i1?� .`... .cit1L '<iZiili'iL�'�2ciy);:<�: F.10. Slope garage slab min. 1/8" per foot to drain. Fl 11. Omit garage curb at door. F 12. Underground conduit for electrical panel and meter. F 13. Condenser and pump on concrete pad. Verify pad size and location of freon lines. Verify and maintain unit side clearances per manufacturer's requirements. F 14. Contractor shall verify all site dimensions including elevations and resolve all conflicts on plan with "Terra Sole Design Group" prior to bidding and Proceeding with construction. F 15. Verify location of Waste, Hot & Cold water for tub with manufacturer specification sheet. F 16. Shower with slab/floor drop for shower pan. Hot mopped shower pan shall be inspected upon completion of hot mopping and shall be filled with water for inspection. F 17: Prior to requesting a foundation inspection, the owner's Engineer shall field verify the building pad height and submit a letter to the City Engineer certifying the building pad height as complying with the approved Grading Plan. FRAMING NOTES ROOF SHEETING 5/8" Plywood structural grade II, PII 32/16. With 10 d common nails at 6" ctrs. and supported edges, 12" in field. Run all plywood sheets perpendicular to rafter, joist and truss direction. -Stagger all end joints a minimum of 2 supporting members. LUMBER GRADE all solid rafters, headers, and beams shall be grade #1 douglass fir south or better. All members shall be free of the heart of the tree. WALL STUDS Unless- shown otherwise, all exterior studs shall be on 16" ctrs. All cutting and notching shall be per UBC 2518g10. FLOOR SHEETING 5/8" cdx Plywood, 32/16 PII and toung and grooved . Glue to all joists. Nail with 19d at 6" ctrs. edges and boundry, 10' ctrs. in field. Run all plywood sheets perpendicular to joist direction. Stagger all end joints a minimum of 2 supporting members. RAFTER NOTES All 2x Rafters shall be on 24" or 16" centers. See plans for spacing. Min.2x solid block all rafters and ceiling joists at all bearing plate wall lines and beams. All rafter framing shall have a ridge board one size larger so that the width shall be no less than the angled cut of rafters. TRUSS JOISTS AND BEAMS All truss Joists shall be installed per "Truss Joist Corporation" Installation instructions. Do not notch or cut .top or bottom flange. Holes can be cut in the plywood web only per Manufacturers requirements. All Micro Lam Beams ,Must be Nailed or bolted together per details, Notes and Manufacturers Requirements. STRUCTURAL NOTES 1. Use common nails. 2. At top splice, provide ( ) 16d at each side of splice. 3,. Were shown, provide 1 x 6 diagonal let in brace per UBC B1-2518g5a or an Simpson CWB. ,See symbol on plans. 4. Shear Walls. Provide 3/8" plywood, structural II with 8d at 2 1/2" ctrs. at edges, 12" ctrs. in field. Block all edges at all 2 1/2" ctr. edge nailing, provide minimum 3" nominal nailing member. Provide Simpson HDSA holdowns on 4x D.F. #2 (or better) posts at 'ends of 'shear panel. Run posts continious from bottom to top plate or povide Simpson MST48 centered and at both sides of post splice. 3/4" holdown anchor- bolts 'to have standard J. bolt .with 4x diameter return or standard L. bolt with 12x diameter extension. Provide 5/8" diameter by 10" anchor bolt. at 16" ctrs. and embed A.B. a minimum of 7 1/2" into cone. between holdowns.at shear panel. 5. All interior walls use Ramset 3320 (ICBG # 1639)at 32" ctrs.except at walls with plywood sheathing were spacing of Ramset shall be on 12" ctrs and 611.from ends. 6. 2X Framing to be min. D.F. No. 2. CEILING FRAMING PLAN NOTES CF1. Nail all double. 2x joists together) with 16D staggered et -11-" centers. ! CF2. Nail all 2x ledgers (ceiling framing only) to each wall stud with (3) 16D nails at each stud, min. 1-3/4" apart and min. 1-1/4" from ledger and stud -end. CF3. All 2 x joists to be construction grade #1.D.F. south or better. CF4. See roof framing plan for header and' beam sizes not shown. CF5. Ceiling joists spans to comply with table 25 -U -J-1 through 25 -U -R-14 per section 2517 (D).of the UBC. .�.. : e< ..! 5 _ r . .. i . ..K , x . ...vy::. 2cie12a:'i . S : •.t.t.. . S.• .. . . 2'z . '. � ot�.�r..: r.c, .2 e r r�r. .•enc .T., i�. ..>..<.� .. ..... ... .. .