Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
04-4734 (SFD)
Application Number . . . . . Property Address . . . . APN: Application description . . . Property Zoning . . . . . . . Application valuation Owner LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111, STE C LA QUINTA, CA LA QUINTA CA 9.2253 BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 ?253 INSPECTION REQUESTS (760) 777-7153 NG PERMIT ,04-7-00_.0.047_34___..__ Date 7/09/04 43439 BORDEAUX DR 609-380-997-51 -293233- DWELLING - SINGLE-FAMILY DETACHED LOW DENSITY RESIDENTIAL 136306 Contractor ------------------------ LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, SUITE C LA QUINTA CA 92253 Qty Unit Charge Per Extension WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone ... . . . . . . NON -AO FLOOD ZONE Other struct info . . . CODE EDITION 2001 CRC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 425.00 PATIO SQ FTG 53.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2225.00 ---------------------------------------------------------------------------- Permit . . . . BUILDING PERMIT Additional desc Permit Fee 769.00 Plan -Check Fee 499-.85 Issue Date . . . . Valuation . . . . 136306 Qty Unit Charge Per Extension BASE FEE 639.50 37.00 3.5000 THOU BLDG 100,001-500,000 129.50 -------------------------------------------- Permit . . . . . . -------------------------------- MECHANICAL Additional desc Permit Fee 39.50 Plan Check Fee 9.88 • Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension P.O. BOX 1504 • VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: ©q - Date: k' 16 O y Applicant:—Architect Applicant's Mailing Address: Architect Lic. No.: or Engineer: or Engineer's Address: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of.the Business and Professionals P0 �and my LicenV in full force and effect. /� —7d -off 0 D %e Class License No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ►'V have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is iss ed,y worke cp�pensation�ance carrier li m e are' /er a F-F�.�,/ LIC P� olicy Number = are, I certify tha , n the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS. UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lenders Address Ir APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. /Date �`� -I Sig(Applicant or Agent): Page 2 Application Number 04-00004734 Date 7/09/04 Qty 'Unit Charge Per Extension BASE FEE 15.00 1.0,0 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 -----------------------------------------------------------------------'----- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 101.38 Plan Check Fee 25.35 Issue Date . . . . Valuation . . . . 0 Qty Unit'Charge Per Extension BASE FEE 15.00 2225.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 77.88 4'25.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.50 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 152.25 Plan Check Fee 38.06 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc Permit Fee 15.00 Plan Check Fee'. .00 Issue Date . . . . Valuation . . . . 0 Qty -Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 51. PLAN 4. PERMIT DOES NOT 1� Page 3 Application Number . . . . . 04-00004734 Date m 7/09/04 ---------------------------------------------- Notes and Comments INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 49.99 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 13.63 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary. Charged ---------- Paid Credited Due ----------------- Permit Fee Total 1077.13 ------------------------------ .00 .00 1077.13 Plan Check Total 573.14 .00 .00 573.14 Other Fee Total 2468.62 .00 .00 2468.62 Grand Total 4118.89 .00 .00 4118.89 PREPARED 10/02/09, 16:48:11 INSPECTION HISTORY REPORT PAGE 1 PROGRAM BP521L 0/00/00 THRU 0/00/00 CITY OF LA QUINTA ------------------------------------------------------------------------------------------------------------------------------------ APPLICATION PROPERTY ADDRESS APN Alternate ID STRUCTR ------------------------------------------------------------------------------------------------------------------------------------ PERMIT INSPECTION RESULT DATE/STATUS INSPECTOR 04 00004734 43439 BORDEAUX DR 609-380-997-51 -293233- 000 000 B001 00 BUILDING PERMIT 100 0001 SETBACKS 12/09/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT 120 0001 FOOTINGS 12/09/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT 125 0001 SLAB 12/09/04 APPROVED TM 000 000 B001 00 BUILDING PERMIT 135 0001 ROOF NAIL 2/03/05 CANCELLED TM 000 000 B001 00 BUILDING PERMIT 135 0002 ROOF NAIL 2/16/05 APPROVED TM 000 000 B001 00 BUILDING PERMIT 140 0001 OKAY TO WRAP 2/16/05 APPROVED TM 000 000 B001 00 BUILDING PERMIT 145 0001 FRAMING 3/01/05 APPROVED TM 000 000 B001 00 BUILDING PERMIT 150 0001 INSULATION 3/01/05 DISAPPROVED TM 000 000 B001 00 BUILDING PERMIT 150 0002 INSULATION 3/01/05 APPROVED TM 000 000 B001 00 BUILDING PERMIT - 160 0001 DRYWALL NAIL 3/01/05 APPROVED TM 000 000 B001 00 BUILDING PERMIT 155 0001 LATH 3/01/05 APPROVED TM •000 000 B001 00 BUILDING PERMIT 199 0001 FINAL 4/18/05 APPROVED TM ; 000 000 E01 00 ELEC-NEW RESIDENTIAL 310 0001 ROUGH ELECTRICAL 3/01/05.APPROVED TM 000 000 E01 00 ELEC-NEW RESIDENTIAL, 399 0001 ELECTRICAL FINAL 4/18/05 APPROVED TM 000 000 GP 00 GRADING PERMIT 197 0001 GRADING FINAL 4/18/05 APPROVED TM 000 000 MO1 00 MECHANICAL 405 0001 ROUGH MECHANICAL 3/01/05 APPROVED TM 000 000 MO1 00 MECHANICAL 499 0001 MECHANICAL FINAL 4/18/05 APPROVED TM 000 000 P01 00 PLUMBING 200 0001 UNDERGROUND PLUMBING 12/09/04 APPROVED TM 000 000 PO1 00 PLUMBING 210 0001 SEWER CONNECTION 12/09/04 APPROVED TM 000 000 PO1 00 PLUMBING 230 0001 ROUGH PLUMBING 3/01/05 APPROVED TM 000 000 PO1 00 PLUMBING 245 0001 SHOWER PAN 3/01/05 APPROVED TM 000 000 PO1 00 PLUMBING 235 0001 GAS LINE / GAS TEST 3/01/05 APPROVED TM 000 000 PO1 00 PLUMBING 299 0001 PLUMBING FINAL 4/18/05 APPROVED TM Q Certificate of Insulation Your home has been insulated with John Mansville Fibeglass insulation products, which are designed for today's safety standards and tomorrows energy requirements. L tt /w Fiberglass is inorganic and therefore permanently noncombust ble, so it does not have to be treated with fire -retardant chemicals that will likely lose their effectiveness overtime. It has not been treated with chemicals that can corrode wiring or metal. Fiberglass will not absorb moisture nor will it settle over time as may other insulation materials. This also certifies that insulation have been professionally installed in this home to provide the following thermal performance. Lennar Homes Job Name: Tapestry at Esplanade Tract: 29323 Plan# 4113 Phase: Lot No: 51 Job Address: SFR - 43-439 Bordeaux Drive, La Qulnta, CA Ceiling Area: R-38 blown and batt lr.suiatlan Garage Ceiling: Non-Access:— With Living Above & Sloping Areas Exterior Walls R-13 batt insulation Overhangs: Access Attic: Between Floors: With Living Above Interior Walls: Subcontractor...0 J insulation, Inc. 72-227 Adelaid St, Thousand Palms, CA 92276 10 Signed: 1!'1, � . a-gr,1�i� Mike Dickerson, General Manager - Palm Springs Branch R -means resistance to heat flow. The higher the R -value, the greater the insulating power. Ask your bui'der for the fact sheet on R -values. Keep this certificate with your other valued papers. If you ever self this home, this certificate should be passed on to the buyer. �"'rR-12-2005 TUE 08:29 AM TEAM HEATING & A/C FAX NO. 9516943803 Pr 11 MVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Tract Number. Lot Number. 51 Project: Esplanade Builder: Lennar Homes An installation certificate is required to be posted at the building site or made avalihle for all appropriate inspections. After completion of final inspection, a Copy must be provided to the Building Department (upon request) and the budding owner at occupancy, per Secpon 10-103(b). 29323 1 &2 CF -6R Plan # 4 Phase: 10 HVAC SYSTEMS: t-tcntinn P+n11inmant o cceney Duct cooling Gooling quip.r --- LEC-CeithedName Identicle (SEER, etc.) Location puck Load Capacity Type and Model Number Systems (>--CF-IR) (attic, eta) R -value (BTU / Hr) (BTU i Hr) ran a c ym a c 1, me uncermoneu, Wnly mdl Uq UIP)TWIlk R WG %4UWVU 1a. 11113 1/10 oi.wur W41,41141Sc+in 1'raww0v, L) Wyvr-..,..r.- efficient than that specified in dflM of compliance (Form CF -1R) submitted for compliance with the Energy Efficiency Standards for resi n al i ing , a ) equipment that meets or exceeds the appropriate requirements for manufactured devices ( a pl a ce gulation or Fairt, where applicable. D Team Healing & Air, Inc Signat4r-0715= Installing Subcontrador me OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: System M of Indicate ft ma mum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.08) for Climate Zone 8 through Is 0.5 x Floor Area x (0.06) for Crimato Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tors) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow I Ti5a Pressurization Test Result's (CI -M (a 26lsAj 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fall (Pass = 6% or Less) �T-24^w�����Yl7ianm Credit was Taken for TXV System 4 1 of Indicate the maximum alowa-ble Duct Leakage and the calculatlon used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.08) 21.7 x (Heating Capacity In Thousands of 2E!put BTU per hour X_(0.06) Measured Fan Flow Vu -9 Pressurization Test Resp s{ %;UM (M 25 PA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) E=T -24 Compliance Credit was Taken for TXV X'05 X.013 TXV via: TXV wa: PAGE 1 F2001-01 (4-02) Action Now T-24CF6-RTDBTXV macro APR -12-2005 TUE 08:29 AM TEAM HEATING & A/C FAX N0, 9516943803 INSTALLATION CERTIFICATE for Tested Duct cress_ 43-439 Bourdeaus Drive, La.Quinta, Ca I Tract Number 29323 Lot Number. 51 MR & TXV Page 2 of 2 CF -6R Plan #_ 4 Phase; 10 Project Esplanade Builder. Lennar Homes System I --J of Indicate them mum a wa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacl In Thousands of Output BTU per hour) x (0.08) Measured Fan Flow I MR Pressurization Test Results Gf qB 25 PA) 100 x Test Leakage I Fan Flaw = % Leakage Check Box for Pass or Fall (Pass = 6% or Less) j -7T-24 Compliance Credit was Taken for TXV 'system � of [� Indloate the maximum al as le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.08) for Climate Zone 8 through 15 0.5 x Floor Ansa x (0.08) for Climate Zones 1 through 7 & 18 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow I ^� Mu'a Pressurization Test Results (CFM a 20 PA) 100 x Test Leakage / Fan Flow - % Leakage Check Box for Pass or Fail (Pass = 6% or Leas) T 24 Compliance Credit was Taken for TXV m � lt—b Indicate the maximum a owa !e Dud Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tong) x (0.08) 21.7 x (Heating Ca in Thousands of Out ut BTU per hour) x (0.06) Measured Fan Flow VU_d Pressurization Test Rem! its (CFM 23 PA) 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass - 6% or Less) r--IT-24 Compliance Credit was Taken for TXV ys m of Q Indicate them mum Kate Ie Duct Leakage and the calculation used: 0.7 x Floor Area x (0.05) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 18 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity. in Thousands of Output BTU 22r hour) x 0.08) Measured Fan Flow WE Pressurization Test Results 100 x Test Leakage / Fan Flow - % Leakage Check Box for Pass or Fail (Pass = 6% or Less) OT -24 Compliance Credit was Taken for TXV X.126 X .06 x .O6 TXV wa; TXV wai TXV wao I, the undersigned, verly that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requirements for m liance credit (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder employees s rs lying that diagnostic testing and Installation meet the requirements for compliance kxedlt.) Team Heating &Air, Inc es'ii10-taTure, Date ns Ing SuDcontractor(Co.Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (If applicable) Building Owner at Occupancy PAGE 2 F2001-01 L4A Action Now T-24cmRTD&TXV macro CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page 1 of 7) CF4R Tapestry @ Esplanade Project Title Project Address Builder Contact Telephone William Henson 760-250-7022 HERS Rater Telephone Z) Z��Tl - I -d Cerfil5in& Si ature Date Firm: BCI Testing Street Address: I?C)-Bori9i'75 Copies to: Builder, HERS Provider 4/14/2005 Date Lennar Builder Name Plan Number Sample Group Number Sample House Number HERS Provider: CalCerts City/State/Zip: Phocni , A7,85076 HERS RATE COMP CE STATEMENT The house was: Tested Approved as part of sample testing, but was not tested As the HERS rater provi ing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted (i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ ❑ Pass Fail ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Yes is a pass Pass Fail ❑ MINIMUM REQUIREMENTS FOR DUCT DESIGN COMPLIANCE CREDIT I ❑ Yes ❑ No ACCA Manual D Design requirements have been met (rater has verified that actual installation matches values in CF -IR and design on plan. 2. ❑ Yes ❑ No TXV is installed or Fan flow has been verified. If no TXV, verified fan flow matches design from CF -1R. Measured Fan Flow = Yes for both I and 2 is a Pass Pass Fail Compliance Forms August 2001 A-16