04-7080 (BLCK)"j7
P.O. Box 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING PERMIT
BUILDING & SAFETY DEPARTMENT
(760),777-7012
r
FAX (760) 777-7011
INSPECTION REQUESTS (760) 777-7153
Application Number°"..,. .
04-00007080 Date
11/05/04
Property Address . . . . . .
78656 BOTTLE BRUSH DR 1
APN:
646=311=035-35- -000000-
Application description
WALL/FENCE
Property Zoning
MEDIUM DENSITY RES
Application.valuation
6515
Owner
s Contractor
PACIFIC HOMES IN CALIFORNIA
PACIFIC HOMES
P.O. BOX 1023
P.O. BOX 1023
LA QUINTA CA 92253
LA QUINTA
CA 92247
(760) 408-3495
WCC: STATE FUND
WC: 1576557
08/01/05
CSLB: 782324
08/31/06
CCC: B
----------=-----------------------------------------------------------------
Permit . . . . . . WALL/FENCE PERMIT
Additional desc
Permit Fee . . . . 90.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
6515
Qty Unit Charge Per
Extension
BASE FEE
45.00
5.00 9.0000 THOU BLDG 2,001-25,000
'45.00
Special Notes and Comments
200 L.F. 61, 50 L.F.. 5' & 27
L.F. 4'
BLOCK WALLS ALL CITY STANDARD
Fee.summary Charged
Paid Credited
Due
Permit Fee Total 90.00
.00 .00
90.00
Plan Check Total .00
..00 .00
.00
Grand Total 90.00
.00 ._00
90.00
C')
37
o r �� �,
P.O. Box 1504�� VOICE (760) 777-7012
78-495 CALLS TAMPICO TdY
FAX (760) 777-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT
Application Number: 700 Date: /'�� "0
Applicant:
Applicant's Mailing Address:
Architect or Engineer:
Architect or Engineer's Address:
Lic. No..
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencin with Section 7000) of Division 3 of the Business and Professionals
Code, and my Li0he is in full force and effect. —79-,)
License Class /Ci/cense No. C_f �c J
,,,-6ate gL4 ntract.r
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' State License Law.).
U I am exempt under Sec. , B.8 P.C. for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
rkers' compensation i ce carie nd_p�jis nu e.
�rrier 5� �licy Number 1 ' / /
_ 1 certify at, in the performance of the work for which his pe it is issued, I shall n t employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those proAsions,--, _
/bate /Applicants/
WARNING: FAIRE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name
Lender's Address
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building
construction, and h a authorize representatives of this county to enter upon above-mentioned property for inspection purposes.
ate nature (Applicant or Agent):
TITLE 24 REPORT
Title 24 Report for:
MALIBU DS - (Complies in 4 -Cardinal Directions)
78-656 Bottlebrush
La Quinta, Ca 92253
Project. Designer:
Lendel Ventures, Inc. DBA Lench Design Group
P.O. BOX 450
LA QUINTA, CA 92253-0450
760/564-1866
Report Prepared By:
VERNA LENCH
Lendel Ventures, Inc
P.O. Box 450
La Quinta, CA 92253-0450
(760) 564-1866
Job Number:
3.1-1295
Date:
10/19/2004
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
FOR CONSTRUCTION NS TRU CTI O N
DAML9 - :.L_ 6Y oS _r
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900.
EnergyPro 3.1 By EnergySoft Job Number: 3.1-1295 User Number: 5454
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance .3
Form MF -1 R Mandatory Measures Checklist 6
Form C -2R Computer Method Summary 7
HVAC System Heating and Cooling Loads Summary 11
Room Load Summary 12
Room Heating Peak Loads 13.
Room Cooling Peak Loads 14
EnergyPro 3.1 By EnergySoft Job Number: 3.1-1295 User Number: 5454
Certificate of Compliance: Residential (Part 1 of 2) CF -1 R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
78-656 Bottlebrush La Quinta
Project Address Building Permit #
Lendel_Ventures, Inc (760) 564-1866 Plan Check I Date
Documentation Author Telephone
Computer Performance 15 Field Check / Date
Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only
GENERAL INFORMATION '
Total Conditioned Floor Area: 1,805 f? Average Ceiling Height: 10.0 ft
Total Conditioned Slab Area: 1,805 f?
Building Type:
(check one or more)
X] Single Family Detached ❑ Addition
❑ Single Family Attached ❑ Existing Building
❑ Multi -Family ❑ Existing Plus Addition
Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor
Number of Dwelling Units: 1.00
Number of Stories: 1 ❑ Raised Floor
Const.
Component Frame Assembly Location/Comments
TVDe Type U -Value (attic, garage, typical, etc.)
R-38 Roof (R.38.2x14.16)
Wood
0.028
Exterior Roof
Slab On Grade
n/a
0.756
Exposed Slab w/R-0.0 Perimeter Insulation
Slab On Grade
n/a
0.756
Covered Slab w/R-0.0 Perimeter Insulation
R-13 Wall w/1" EPS
Wood
0.059
Exterior Wall
Solid Wood Door
None
0.387
Exterior Door
R-13 Wall (W.13.2x4.16)
Wood
0.088
Exterior Wall
FENESTRATION
Shading Devices
Type Orientation
Area
SF
U -Factor
Fenestration
SHGC
Exterior
Shading
Overhang Side Fins
Yes / No Yes / No
Skylight
24.0
0.70
0.83
None
❑
0
❑x❑
Front
40.0
'0.74
0.37
Bug Screen
❑
x❑
❑ x❑
Left
72.7
0.61
0.39
Bug Screen
1:1
R1
El
Rear
48.0
0.74
0.37
Bug Screen
X❑
1:1
El X❑
Rear
12.0
0.60
0.37
Bug Screen
x❑
❑
❑ x❑
Left
48.0
0.74
0.37
Bug Screen
❑x
❑
❑ x❑
Rear
7.5
0.46
0.37
Bug Screen
❑
x❑
❑ x❑
Rear
25.0
0.62
0.38
Bug Screen
❑
x❑
❑X❑
Right
54.0
0.61
0.39
Bug Screen
❑
x❑
❑X❑
1:1
El
El F-1
F-1
El
El
Run Initiatiori Time: 10/19104 04:44:25 Run Code: 1098186265
Ener ro 3.1 B Ener Soft
User Number: 5454
Job Number: 3.1-1295
Pa e:3 of 15
Certificate of Compliance: Residential
(Part 2 of 2) CF -1 R
MALIBU DS - (Complies in 4 -Cardinal Directions)
10/19/2004
Project Title
Date
HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping
Thermostat Location /
pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value
Type' Comments
Central Furnare 80% AFUE Ducts in Attic 42
Setback HVAC System
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct
Thermostat Location /
heat pump, evap. cooling) (SEER) (attic, etc.) R -Value
Type Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2
Sethack HVA(: System
WATER HEATING SYSTEMS Rated 1
Tank Energy Facts 1 External
Water Heater Water Heater Distribution # in Input
Cap. or Recovery Standbyy Tank Insul.
System Name Type Type Syst. Btu/hr
(gal) Efficiency Loss ( 0 R -Value
A.O. SMITH FGR -50-240 Small Gas Standard 1_ 38,000 sQ 0.60 n/a n/a
1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss.
For instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
REMARKS
AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES.
NO DUPLICATION PERMITTED!
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any
shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (per Business & Professions Code) Documentation Author
Name:
Title/Firm: Lendel Ventures, Inc. DBA Lench Design Grou
Address: P.O. BOX 450
LA QUINTA, CA 92253-0450
Telephone: 760/564-1866
Lic. #:
(signature) (date)
Enforcement Agency
Name:
Title/Firm:
Address:
Telephone:
Name: VERNA LENCH
Title/Firm: Lendel Ventures, Inc
Address: P.O. Box 450
La Quinta, CA 92253-0450
Telephone: (760) 564-1866
t5rgnature) (date)
JEnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:4 of 15 1
Certificate of Compliance: Residential (Addendum) CF -1 R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
3ased on the adequacy of the special justification and documentation submitted. Plan I Field
The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1182 sgft Exposed Slab Floor, 3.50" thick at Whole House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 623 sqft Covered Slab Floor, 3.50" thick at Whole House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the suDervision of a CEC aDDroved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R.
Plan
Field
The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
I EnergvPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:5 of 15 1
Mandatory. Measures Checklist: Residential MF -1 R.
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an
asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into
the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they
are shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable.
DESIGNER
ENFORCEMEN
Building Envelope Measures
'§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value.
§ 150(b): Loose fill insulation manufacturer's labeled R -Value.
.§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to
exterior mass walls).
'§ 150(d): Minimum R-13 raised floor insulation in framed floors.
§ 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch.
lFV 11 §118: Insulation specified or installed meets insulation quality standards. Indicate type and form.
LN§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls
1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards.
® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs.
1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue
damper and control;
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
X❑ §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA.
X❑ §150(i): Setback thermostat on all applicable heating and/or cooling systems.
§1500): Pipe and Tank Insulation
1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12.
2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater)
3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16
combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating sections of hot water systems.
5. Cooling system piping below 55 degrees F. insulated.
6. Piping insulating between heating source and indirect hot water tank.
X❑ '§150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and
Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed
with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or
UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or
tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and
their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with
mastic and drawbands.
2. Exhaust fans systems have back draft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers.
a§114: Pool and Spa Heating Systems and Equipment
1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot.
2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas.
3. Pool system has directional inlets and a circulation pump time switch.
X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot
light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
Lighting Measures
FX-] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general
lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an
entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt
or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and
recessed ceiling fixtures are IC (insulation cover) approved.
EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:6 of 15
Computer Method Summary (Part 1 of 3) C -2R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
78-656 Bottlebrush La Quinta
Project Address Building Permit #
Lendel Ventures, Inc (760) 564-1866
Documentation Author - Telephone Plan Check/Date
Computer Performance 15 Field Check/Date
Compliance Method (Package or Computer) Cimate Zone
Source Energy Standard
Use (kBtu/sf-yr) Design
Facing
North Margin
Ll
❑
Facing
East Margin
Door 24 0.319 n _90
Wall 35 52 270 �0
0.0
Wall 22 0.052 _0 �go
Facing
South Margin
❑
❑
❑
Facing
West Margin
Wall 20 0 059 270 90
Wall 13 0.052 _a _90
Wall 13 0.059 90 90
'3.42 0.07
3.18 0.32
3.49 0.00
3.55 -0.05
Space Heating 3.50
❑
R-13 Wall w/1" EPS Whnip HoijSe
Wall_ 13 0.059_ 27n _go
Wall 13 0.052 45 90
Wall 20 0.052 90 90
Space Cooling 39.15
37.23 1.91
Nall 22 0 059 -n -90
36.45 2.69
❑
37.18 1.97
Wall 367 0.052 An g0
36.06 3.09
❑
Domestic Hot Water 13.92
1 12.12 1.79
12.12 1.79
R-13 Wall w/1" EPS Whole Hnuse
1 12.12 1.79
12.12 1.79
R-13 Wall w/1" EPS Whole House
1 52.78 8
52.80 3
R-13 Wall w/1" EPS Whole Hnuse
Totals 56.57
❑
R-13 Wall w/1" EPS Whole House
Wall 213 0.088 _1L _90
BUILDING
COMPLIES
This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence.
This plan has been analyzed with identical features in all orientations.
GENERAL INFORMATION
Conditioned Floor Area: 1,805 Floor Construction Type: [Z Slab Floor
Building Type: Single Fam Detached
El Raised Floor
Building Front Orientation: All Four Orientations
Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,050
Number of Stories: 1 Slab Floor Area: 1,805
BUILDING ZONE INFORMATION # of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAr System 1 805 18 050 1 nn Cnnrlitinnerl SPthark n/a
OPAQUE SURFACES Solar
Act. Gains
Type Area U -Val, Azm. Tilt Y / N Form 3 Reference
Location / Comments
Rnnf 1,781 0.028 0 Q
Wall_ 16 0 059 _9Q
LN
®
Ll
❑
R-38 Roof (R 38.2x14-16) Whole House
R-13 Wall w/1" FPS Whnle Hnuse
Door 24 0.319 n _90
Wall 35 52 270 �0
0.0
Wall 22 0.052 _0 �go
❑
❑
❑
Solid Wnnd nnnr Whnip Hnuse
R-13 Wall w/1" FPS Whole House
R-13 Wall w/1" EPS Whole House
Wall 20 0 059 270 90
Wall 13 0.052 _a _90
Wall 13 0.059 90 90
❑
❑
❑
R-13 Wall w/1" FPS Whnle Hnuse
R-13 Wall w/1" EPS Whnle Hnuse
R-13 Wall w/1" FPS Whole House
Wall 37 0.052 () -gQ
®
❑
R-13 Wall w/1" EPS Whnip HoijSe
Wall_ 13 0.059_ 27n _go
Wall 13 0.052 45 90
Wall 20 0.052 90 90
❑
❑
❑
13-13 Wall w/1" FPS Whnle Hnuse
13-13 Wall w/1" EPS Whole House
R-13 Wall w/1" EPS Whole House
Nall 22 0 059 -n -90
®
❑
R-13 Wall w/1" EPS Whnle Hnuse
Wall 367 0.052 An g0
EX
❑
R-13 Wall w/1" FPS Whnle Hnuse
Wall 61 0.052 180 90
❑
R-13 Wall w/1" EPS Whole Hnuse
Wall 102 0.052 90 90
❑
R-13 Wall w/1" EPS Whole House
Wall 238 0.052 X80 90
❑
R-13 Wall w/1" EPS Whole Hnuse
Wall 366 0.052 270 90
❑
R-13 Wall w/1" EPS Whole House
Wall 213 0.088 _1L _90
R-13 Wall (W 132x4.16) Whnle Hnuse
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Run Initiation T*mem 10/19/04 04E44925 Run Codem 1098186265
EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:7 of 15
Computer Method Summary (Part 2 of 3) C -2R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
FENESTRATION SURFACES
U- Act. Glazing Type Location/
# Type Area Factor SHGC Azm. Tilt Comments
9
10
11
12
13
14
15
16
17
18
T9 -
Bug
SkylBht
Front
nrth)
4"0
0700_
0.83
�_
0 Skylight -Dual Glaze
Whnip Hnuse
2
Skylight
Front
(North)
4.0
0.700
0.83
0
0 Slight - Dual Glaze
Whole House
3
Slight
Front
(North)
4.0
0.700
0.83
0
0 Skylight - Dual Glaze
Whole House
4
Skylight
Front
(North)
4.0
0.700
0.83
0
0 Skylight - Dual Glaze
Whole House
5
Skylight
Front
(North)
4.0
0.700
0.83'
0
0 Skylight - Dual Glaze
Whole House
6
Skylight
Front
(North)
4.0
0.700
0.83
0 0 Sight - Dual Glaze
Whole House
Z
Window
Front
(North)
40.0
0.740
0.37
0
90 Summit 5500 Al DP Low E
Whole House
8
Window
Left
(East)
30.0
0.610
0.39
90
90 Summit 5500 Al DP Low E
Whole House
5
Window
Left
(Fast)
_ 12.7
0.610
0.39
90
90 Summit 5500 Al DP Low E
Whole House
1Q
Window
Left
(East)
30.0
0.610
0.39
90
90 Summit 5500 Al DP Low E
Whole House
"
Window
Rear
(South)
48.0
0.740
0.37
180
90 Summit 5500 Al DP Low E
Whole House
12
Window
Rear
South
12.0
0.600
0.37
180
90 Summit 5500 Al DP Low E
Whole House
j_3_
Window
Left
(East)
480
0.740
0.37
90
90 Summit 5500 Al DP Low E
Whole House
14
Window
Rear
(South)
7.5
0.460
0.37
180
90 Summit 5500 At DP Low E
Whole House
15
Window
Rear
(South)
16.0
0.620
0.38
180
90 Glass Block
Whole House
16
Window
Rear
South
9.0
0.620
0.38
180
90 Glass Block
Whole House
17
Window
Right
(West)
6.0
0.610
0.39
270
90 Summit 5500 Al DP Low E
Whole House
18
Window
Right
_(West)
24.0
0.610
0.39
270
90 Summit 5500 Al DP Low E
Whole House
-12
Window
Right
(West)
24.0
0.610
0.39
270
90 Summit 5500 Al DP Low E
Whole House
INTERIOR AND EXTERIOR SHADING
Window
Overhanq Left Fin
Right Fin
#
Exterior Shade Type
SHGC
Hgt. Wd.
Len. Hgt.
LExt. REA Dist. Len.
Hgt. Dist. Len. Hgt.
1
None
1.00
2
None
1.00
3
None
1.00
4
None
1.00
5
None
1.00
6
None
1.00
7
Bug Screen
0.76
8
Buq Screen
0.76
9
10
11
12
13
14
15
16
17
18
T9 -
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Bug
Screen
Screen
.Bug
Bug
Screen
0.76
0.76
0.76 8.0 6.0
0.76 6.0 2.0
0.76 8.0 6.0
0.76
0.76
0.76
0.76
0.76
0.76
10.0 0.1 10.0 10.0
10.0 0.1 10.0 10.0
10.0 0.1 10.0 10.0
EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:8 of 15 1
Comauter Method Summary (Part 3 of 3) C -2R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick. Heat Inside Location
Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments
Concrete, Heavyweight 1,192 3 sn _28 0"98 n/a Whole House / Slab on Grarfe
Concrete, Heavyweight 623 3_50 28 0_98 n/a 2 Whole House / Slab on Grade
PERIMETER LOSSES
F2 Insulation
Type Length Factor R -Val. Depth Location / Comments
Slab Perimeter 169 0.76 0.0 0 Whole House
Slab Perimeter 21 0-76 0.0 D Whole House
HVAC SYSTEMS
Heating Equipment Minimum Distribution Type
Type (furnace, heat Efficiency and Location Duct Thermostat
Location /
pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type
Comments
Central Furnace 80%AFUE Ducts in Attic 4.2 Setback
HVAC System
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
Cooling Equipment Minimum Duct
Type (air conditioner, Efficiency Location Duct Thermostat
Location /
heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type
Comments
Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback
HVAC System
WATER HEATING SYSTEMS Ratedl Tank
Energy Fact! 1 Tank Insul.
Water Heater Water Heater Distribution # in Input Cap.
or Recovery Standby R -Value
System Name Type Type Syst. (Btu/hr) (gal)
Efficiency Loss (%) Ext.
A.O. SMITH FGR -50-240 Small Gas Standard 1 38,000 50
0.60 n/a n/a
1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor.
For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby
Loss.
For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency.
Run Initiation Time: 10/19/0404:44:25 Run Code: 1098186265
Ener Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1295 Pa e:9 of 15
Computer Method Summary (Addendum) C -2R
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency should pay special attention to the items specified in this checklist. These items require special
written justification and documentation, and special verification to be used with the performance approach. The local
enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies
3ased on the adequacy of the special justitication and documentation submitted. Plan I Field
The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual.
HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1182 sgft Exposed Slab Floor, 3.50" thick at Whole House
HIGH MASS Design(see C -2R) - Verify Thermal Mass: 623 sgft Covered Slab Floor, 3.50" thick at Whole House
HERS Required Verification
These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS
provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R.
Plan
Field
The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide
verifification of the TXV, or measure the Refrigerant Charge and Airflow.
The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage
performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form.
Run Initiation Time: 10/19/04 04:44:25 Run Code: 1098186265
EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page: 10 of 15
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
DATE
MALIBU DS - (Complies in 4 -Cardinal Directions
10/19/2004
SYSTEM NAME
FLOOR AREA
HVAC System
1.805
KS
Number of Systems
1
Heating System
Output per System
65,000
Total Output (Btuh)
65,000
Output (Btuh/sgft)
36.0
Cooling System
Output per System
59,000
Total Output (Btuh)
59,000
Total Output (Tons)
4.9
Total Output (Btuh/sgft)
32.7
Total Output (sgft/Ton)
367.1
Air System
CFM per System
1,400
Airflow (cfm)
1,400
Airflow (cfm/sgft)
0.78
Airflow (cfm/Ton)
284.7
Outside Air (%)
0.0
Outside Air (cfm/sgft)
0.00
Note: values above given at ARI conditions
26.0 OF
?�
Outside Air
0 cfm
68.9 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensible
Latent
CFM
I Sensible
1,674
32,060
2,729
716
32,161
0
1,603
1,608
0
0
0
0
0
0
0
0
0
1,603
1,608
35,266 2,729 35 378
YORK DlNH060NO6506 40,385 13,178 65,000
Total Adjusted System Output 40,385 13,178 65,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am
68.9 OF 68.9 OF n 112.20F
Supply Fan Heating Coil
1400 cfm
h Return Air Ducts "I
Supply Air Ducts
111.1oF
ROOMS
70.0 of
I
DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
111.0 / 77.6 of 79.1 / 66.0 of 79.1 / 66.0 of 60.0 / 58.9 of
Supply Air Ducts
Outside Air O'
0 cfm Supply Fan Cooling Coil 61.1 / 59.3 of
1400 cfm 52.4% R.H. ROOMS
79.1/66.0 of ri 78.0 / 65.7 of
3.1
User Number: 5454
Return Air Ducts
Job Number: 3.1-1295
1of15
ROOM LOAD SUMMARY
PROJECT NAME
MALIBU DS - (Complies in 4 -Cardinal Directions
DATE
10/19/2004
SYSTEM NAME
HVAC System
FLOOR AREA
1,805
ROOM LOAD SUMMARY
ROOM COOLING PEAK
COIL COOLING PEAK
COIL HTG. PEAK
ZONE NAME
ROOM NAME
Mult.
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
LATENT
CFM
SENSIBLE
Whole House
Whole House
1
1,674
32,060
2,729
1,674
32,060
2,729
716
32,161
PAGE TOTAL 1 1,674 32,060 2,729 716 32,161
TOTAL 1 1,674 32,060 2,729 716 32,161
EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:12 of 15
ROOM HEATING PEAK LOADS
Project Title Date
MALIBU DS - (Complies in 4 -Cardinal Directions 110/19/2004
Room Information Desi n Conditions
Room Name Whole House Time of Peak Jan 12 am
Floor Area 1,805 Outdoor Dry Bulb Temperature 26OF
Indoor Dry Bulb Temperature 70 OF
Conduction Area U -Value Z�T of Btu/hr
IR -13 Wall w/1" EPS I
1,781.0
. X
X
X
X
X
X
X
X
X
X
x
x
X
X
X
X
X
X
X
X
X
X
X
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
0.0280
x
X
X
X
X
X
X
X
X
X
x
x
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
44.0
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
2,195
24.0
0.7000
44.0
739
perimeter = 190.3
44.5
8,468
1,358.8
0.0585
44.0
3,498
24.0
0.3872
44.0
409
136.0
0.7400
44.0
4,428
126.7
0.6100
44.0
3,401
12.0
0.6000
44.0
317
7.5
0,4600
44.0
152
25.0
0.6200
682
213.0
0.0885
44 Q
829
nems shown with an asterisk (-) denote conduction through an interior surtace to another room. Page Total: 25,118
Infiltration: F 1.00 X 1.064 X 1 805 X 10.00 X 0.50 / 6] X 0 = 7 043
chedule Alr Sensible Area Ceiling Height ACH ILT
Fraction
TOTAL HOURLY HEAT LOSS FOR ROOM 32,161
EnergyPro 31 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page: 13 of 15
RESIDENTIAL ROOM COOLING LOAD SUMMARY
MALIBU DS =(Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
Room Name
Design Indoor Dry Bulb Temperature:
Design Outdoor Dry Bulb Temperature:
Design Temperature Difference:
Whole House
780F
112°F
340E
Conduction Area ' U -Value DETD 1 Btu/hr
X
(Skylight)
51.0
=
2,544
X
Sk i ht
34.0
=
571
X
(Skylight)
30.6
=
2,433
X
Window 4032 XO
30.6
=
284
X
152
34.0
=
3 422
X
4.0
34.0
=
2.628
X
X
X
1. Design Equivalent Temperature Difference (DETD)
Page Total 12 771
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Sk i ht
(Skylight)
(Skylight)
Skylight
(Skylight)
Sk i ht
(Skylight)
Skylight
(Skylight)
Skviiaht
(Skylight)
Window 2680 2 FR DR
(North)
Window 5060 XO
(East)
Window 4032 XO
(East)
Window 5060 XO
East
( 0.0
X1
x
X
x
x
X
x
x
X
x
+
+
+
+
+
+
+
+
+
+
4.0
x
X
x
X
X
x
X
x
X
x
152)X
x
) X
x
X
)x
0.954
=
=
=
=
=
=
=
=
__
=
580
( 0.0
1
4.0
152)
0.954
580
( 0.0
1
4.0
152
0.954
580
( 0.0
1
4.0
152)x
0.954
580
( 0.0
1
4.0
152)
0.954
580
( 0.0
1
4.0
152)X
0.954
580
( 0.0
1
40.0
15)
0.412
247
( 0.0
1
30.0
73)x
0.434
951
( 0.0
1
12.7
73)X
0.434
403
( 0.0
1
30.0
I
0.434
951
Sched.
Page Total 6 032
Internal Gain Frac. Area' Heat Gain Btu/hr
Lights 1.00 x 1,805 X 0.500 Watts/sgft x 3.41 BtuhfWatt = 3,080
Occupants 1.00 X 1,805 X 245 Btuh/OCC. / 333 sgft/occ. = 1,328
Receptacle 1.00 x 1 805 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0
Process 1.00 x 1,805 X 0.000 Watts/sgft x 3.412 Btuh/Watt = o
Infiltration: x x 8Il x x / 60] _
Schedule . Air Sensible Area Ceiling Height ACH 4,1T
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,0601
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occu ants 1.00 x 805 X 155 Btuh/OCC. / 333 sgft/occ. = 840
Receptacle 1.00 x 1 805 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0
Process 1.00 x 805 x 0.000 Watts/sqft x 3.41 Btuh[Watt = o
Infiltration: 1.0o X 4 77 x 1 80 x 10.00 x 0.50 / 60] 0.00263 = 1 889
chedule Air Latent Area Ceiling Height ACH DW
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,729
Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1295 Pa e:14 of 15
RESIDENTIAL ROOM COOLING LOAD SUMMARY
MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004
Project Title Date
Room Name Whole House
Design Indoor Dry Bulb Temperature: 780F
Design Outdoor Dry Bulb Temperature: 1120 F
Design Temperature Difference: 340F
Conduction
Area
X
U -Value
Btu/hr
577
1. Design Equivalent Temperature Difference (DETD) , Page Total 577
Items shown with an asterisk (') denote conduction through an interior surface to another room.
Shaded Unshaded
Solar Gain Orientation Area SGF Area SGF SC Btu/hr
Window 3080 2 FR DR
(South)
Wondnvv 217160 SH
(South)
Window 3080 2 FR DR
_(East)
Window 1016 FO 5
(South)
Window 4040 GL BLK
(South)
Window 3030 GL BL
(South)
Window 3020 XO
Window 4060 XO
(West)
(West)
Window 4060 XO
(West) .
74
( 47.4
( 48.0
X1
X
x
X
x
x
x
x
x
+
+
+
+
+
+
+
+
+
+
0.0
x
x
x
x
x
X
x
X
X
x
32
) X
x
x
x
x
X
X
X
) x
)x
0.41
=
=
=
=
=
=
=
=
__
=
297
( 12.0,X
1
0.0
32)
0.412
74
( 47.4
1
0.6
73)
0.41
311
( 0.0
1
7.5
32)
0.41
99
( 0.0
1
16.0
32)
0.423
217
( 0.0
1
9.0
32)
0.423
122
( 0.0
1
6.0
73)
0.434
190
( 0.0
1
24.0
73)
0.434
761
( 0.0
1
24.0
7
0.434
761
(
_ _
Sched:
Page Total 2.8301
Internal Gain Frac. Area Heat Gain Btu/hr
Lights 1.00 x 1,805 X 0.50C Wafts/sgft x 3.41 Btuh/Watt = 3,080
Occupants 1.00 X 1,805 X 24 Btuh/OCC. / 333 sgft/OCc. = 1,328
Receptacle 1.00 x 1,805 x O.00C Watts/sgft x 3.413 Btuh/Watt - 0
Process 1.00 x 1,805 x O-OOC Watts/sgft x 3-413 Btuh[Watt = 00
Infiltration: [� x � x g0 x x � / 60]
Schedule Air Sensible Area Ceiling Height ACH DT
Fraction
TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,060-1
Sched.
Latent Gain Frac. Area Heat Gain Btu/hr
Occupants 1.00 x 1 805 x 155 Btuh/OCC. I 333 sgft/OCC.= 8 0
Receptacle 1.00 x 1 805 x 0.000 Watts/sgft X 3.41 Btuh/Waft = '0
Process ( 1.00 x 1 805 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0
Infiltration: I 1.00 x 4 77 x 1 80 x 10.00 x 60] 0.00263 = 1 889
chedule Air Latent Area Ceiling Height ACH �yy
Fraction
TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,729
Ener Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1295 Page:15 of 15