04-7080 (BLCK)"j7 P.O. Box 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760),777-7012 r FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 Application Number°"..,. . 04-00007080 Date 11/05/04 Property Address . . . . . . 78656 BOTTLE BRUSH DR 1 APN: 646=311=035-35- -000000- Application description WALL/FENCE Property Zoning MEDIUM DENSITY RES Application.valuation 6515 Owner s Contractor PACIFIC HOMES IN CALIFORNIA PACIFIC HOMES P.O. BOX 1023 P.O. BOX 1023 LA QUINTA CA 92253 LA QUINTA CA 92247 (760) 408-3495 WCC: STATE FUND WC: 1576557 08/01/05 CSLB: 782324 08/31/06 CCC: B ----------=----------------------------------------------------------------- Permit . . . . . . WALL/FENCE PERMIT Additional desc Permit Fee . . . . 90.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 6515 Qty Unit Charge Per Extension BASE FEE 45.00 5.00 9.0000 THOU BLDG 2,001-25,000 '45.00 Special Notes and Comments 200 L.F. 61, 50 L.F.. 5' & 27 L.F. 4' BLOCK WALLS ALL CITY STANDARD Fee.summary Charged Paid Credited Due Permit Fee Total 90.00 .00 .00 90.00 Plan Check Total .00 ..00 .00 .00 Grand Total 90.00 .00 ._00 90.00 C') 37 o r �� �, P.O. Box 1504�� VOICE (760) 777-7012 78-495 CALLS TAMPICO TdY FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 700 Date: /'�� "0 Applicant: Applicant's Mailing Address: Architect or Engineer: Architect or Engineer's Address: Lic. No.. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencin with Section 7000) of Division 3 of the Business and Professionals Code, and my Li0he is in full force and effect. —79-,) License Class /Ci/cense No. C_f �c J ,,,-6ate gL4 ntract.r OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , B.8 P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is rkers' compensation i ce carie nd_p�jis nu e. �rrier 5� �licy Number 1 ' / / _ 1 certify at, in the performance of the work for which his pe it is issued, I shall n t employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those proAsions,--, _ /bate /Applicants/ WARNING: FAIRE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and h a authorize representatives of this county to enter upon above-mentioned property for inspection purposes. ate nature (Applicant or Agent): TITLE 24 REPORT Title 24 Report for: MALIBU DS - (Complies in 4 -Cardinal Directions) 78-656 Bottlebrush La Quinta, Ca 92253 Project. Designer: Lendel Ventures, Inc. DBA Lench Design Group P.O. BOX 450 LA QUINTA, CA 92253-0450 760/564-1866 Report Prepared By: VERNA LENCH Lendel Ventures, Inc P.O. Box 450 La Quinta, CA 92253-0450 (760) 564-1866 Job Number: 3.1-1295 Date: 10/19/2004 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION NS TRU CTI O N DAML9 - :.L_ 6Y oS _r The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 3.1-1295 User Number: 5454 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance .3 Form MF -1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 7 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13. Room Cooling Peak Loads 14 EnergyPro 3.1 By EnergySoft Job Number: 3.1-1295 User Number: 5454 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date 78-656 Bottlebrush La Quinta Project Address Building Permit # Lendel_Ventures, Inc (760) 564-1866 Plan Check I Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION ' Total Conditioned Floor Area: 1,805 f? Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 1,805 f? Building Type: (check one or more) X] Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor Const. Component Frame Assembly Location/Comments TVDe Type U -Value (attic, garage, typical, etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof Slab On Grade n/a 0.756 Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation R-13 Wall w/1" EPS Wood 0.059 Exterior Wall Solid Wood Door None 0.387 Exterior Door R-13 Wall (W.13.2x4.16) Wood 0.088 Exterior Wall FENESTRATION Shading Devices Type Orientation Area SF U -Factor Fenestration SHGC Exterior Shading Overhang Side Fins Yes / No Yes / No Skylight 24.0 0.70 0.83 None ❑ 0 ❑x❑ Front 40.0 '0.74 0.37 Bug Screen ❑ x❑ ❑ x❑ Left 72.7 0.61 0.39 Bug Screen 1:1 R1 El Rear 48.0 0.74 0.37 Bug Screen X❑ 1:1 El X❑ Rear 12.0 0.60 0.37 Bug Screen x❑ ❑ ❑ x❑ Left 48.0 0.74 0.37 Bug Screen ❑x ❑ ❑ x❑ Rear 7.5 0.46 0.37 Bug Screen ❑ x❑ ❑ x❑ Rear 25.0 0.62 0.38 Bug Screen ❑ x❑ ❑X❑ Right 54.0 0.61 0.39 Bug Screen ❑ x❑ ❑X❑ 1:1 El El F-1 F-1 El El Run Initiatiori Time: 10/19104 04:44:25 Run Code: 1098186265 Ener ro 3.1 B Ener Soft User Number: 5454 Job Number: 3.1-1295 Pa e:3 of 15 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts, attic, etc.) R -Value Type' Comments Central Furnare 80% AFUE Ducts in Attic 42 Setback HVAC System Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Sethack HVA(: System WATER HEATING SYSTEMS Rated 1 Tank Energy Facts 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standbyy Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss ( 0 R -Value A.O. SMITH FGR -50-240 Small Gas Standard 1_ 38,000 sQ 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS AUTHORIZATION FOR USE OF THIS TITLE 24 REPORT ONLY WITH ORIGINAL SIGNATURES. NO DUPLICATION PERMITTED! COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/Remarks section. Designer or Owner (per Business & Professions Code) Documentation Author Name: Title/Firm: Lendel Ventures, Inc. DBA Lench Design Grou Address: P.O. BOX 450 LA QUINTA, CA 92253-0450 Telephone: 760/564-1866 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: VERNA LENCH Title/Firm: Lendel Ventures, Inc Address: P.O. Box 450 La Quinta, CA 92253-0450 Telephone: (760) 564-1866 t5rgnature) (date) JEnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:4 of 15 1 Certificate of Compliance: Residential (Addendum) CF -1 R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justification and documentation submitted. Plan I Field The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1182 sgft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 623 sqft Covered Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the suDervision of a CEC aDDroved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. I EnergvPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:5 of 15 1 Mandatory. Measures Checklist: Residential MF -1 R. NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMEN Building Envelope Measures '§ 150(a): Minimum R-19 ceiling insulation in wood frame assembly, or equivalent U -value. § 150(b): Loose fill insulation manufacturer's labeled R -Value. .§150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does not apply to exterior mass walls). '§ 150(d): Minimum R-13 raised floor insulation in framed floors. § 150(1): Slab edge insulation - water absorption rate <= 0.3%, water vapor transmission rate <= 2.0 perm/inch. lFV 11 §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. LN§116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified SHGC, and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ® §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have closable doors, outside air intake with damper and control, and flue damper and control; 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures X] §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. X❑ §150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. X❑ §150(i): Setback thermostat on all applicable heating and/or cooling systems. §1500): Pipe and Tank Insulation 1. Storage gas water heaters with less than 0.58 energy factor shall be externally wrapped with R-12. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. X❑ '§150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed in conditioned space. Openings shall be sealed with mastic, tape aerosol sealant or other duct- closure system that meets the applicable requirements of UL181, UL181A, or UL181 B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh tape or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fans systems have back draft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. a§114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof instructions, no electric resistance heating, no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. 3. Pool system has directional inlets and a circulation pump time switch. X] §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) Lighting Measures FX-] §150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:6 of 15 Computer Method Summary (Part 1 of 3) C -2R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date 78-656 Bottlebrush La Quinta Project Address Building Permit # Lendel Ventures, Inc (760) 564-1866 Documentation Author - Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Facing North Margin Ll ❑ Facing East Margin Door 24 0.319 n _90 Wall 35 52 270 �0 0.0 Wall 22 0.052 _0 �go Facing South Margin ❑ ❑ ❑ Facing West Margin Wall 20 0 059 270 90 Wall 13 0.052 _a _90 Wall 13 0.059 90 90 '3.42 0.07 3.18 0.32 3.49 0.00 3.55 -0.05 Space Heating 3.50 ❑ R-13 Wall w/1" EPS Whnip HoijSe Wall_ 13 0.059_ 27n _go Wall 13 0.052 45 90 Wall 20 0.052 90 90 Space Cooling 39.15 37.23 1.91 Nall 22 0 059 -n -90 36.45 2.69 ❑ 37.18 1.97 Wall 367 0.052 An g0 36.06 3.09 ❑ Domestic Hot Water 13.92 1 12.12 1.79 12.12 1.79 R-13 Wall w/1" EPS Whole Hnuse 1 12.12 1.79 12.12 1.79 R-13 Wall w/1" EPS Whole House 1 52.78 8 52.80 3 R-13 Wall w/1" EPS Whole Hnuse Totals 56.57 ❑ R-13 Wall w/1" EPS Whole House Wall 213 0.088 _1L _90 BUILDING COMPLIES This C -2R summarizes the results of a four cardinal orientation analysis. The pages that follow describe the front facing North occurence. This plan has been analyzed with identical features in all orientations. GENERAL INFORMATION Conditioned Floor Area: 1,805 Floor Construction Type: [Z Slab Floor Building Type: Single Fam Detached El Raised Floor Building Front Orientation: All Four Orientations Number of Dwelling Units: 1.00 Total Conditioned Volume: 18,050 Number of Stories: 1 Slab Floor Area: 1,805 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAr System 1 805 18 050 1 nn Cnnrlitinnerl SPthark n/a OPAQUE SURFACES Solar Act. Gains Type Area U -Val, Azm. Tilt Y / N Form 3 Reference Location / Comments Rnnf 1,781 0.028 0 Q Wall_ 16 0 059 _9Q LN ® Ll ❑ R-38 Roof (R 38.2x14-16) Whole House R-13 Wall w/1" FPS Whnle Hnuse Door 24 0.319 n _90 Wall 35 52 270 �0 0.0 Wall 22 0.052 _0 �go ❑ ❑ ❑ Solid Wnnd nnnr Whnip Hnuse R-13 Wall w/1" FPS Whole House R-13 Wall w/1" EPS Whole House Wall 20 0 059 270 90 Wall 13 0.052 _a _90 Wall 13 0.059 90 90 ❑ ❑ ❑ R-13 Wall w/1" FPS Whnle Hnuse R-13 Wall w/1" EPS Whnle Hnuse R-13 Wall w/1" FPS Whole House Wall 37 0.052 () -gQ ® ❑ R-13 Wall w/1" EPS Whnip HoijSe Wall_ 13 0.059_ 27n _go Wall 13 0.052 45 90 Wall 20 0.052 90 90 ❑ ❑ ❑ 13-13 Wall w/1" FPS Whnle Hnuse 13-13 Wall w/1" EPS Whole House R-13 Wall w/1" EPS Whole House Nall 22 0 059 -n -90 ® ❑ R-13 Wall w/1" EPS Whnle Hnuse Wall 367 0.052 An g0 EX ❑ R-13 Wall w/1" FPS Whnle Hnuse Wall 61 0.052 180 90 ❑ R-13 Wall w/1" EPS Whole Hnuse Wall 102 0.052 90 90 ❑ R-13 Wall w/1" EPS Whole House Wall 238 0.052 X80 90 ❑ R-13 Wall w/1" EPS Whole Hnuse Wall 366 0.052 270 90 ❑ R-13 Wall w/1" EPS Whole House Wall 213 0.088 _1L _90 R-13 Wall (W 132x4.16) Whnle Hnuse ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation T*mem 10/19/04 04E44925 Run Codem 1098186265 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:7 of 15 Computer Method Summary (Part 2 of 3) C -2R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments 9 10 11 12 13 14 15 16 17 18 T9 - Bug SkylBht Front nrth) 4"0 0700_ 0.83 �_ 0 Skylight -Dual Glaze Whnip Hnuse 2 Skylight Front (North) 4.0 0.700 0.83 0 0 Slight - Dual Glaze Whole House 3 Slight Front (North) 4.0 0.700 0.83 0 0 Skylight - Dual Glaze Whole House 4 Skylight Front (North) 4.0 0.700 0.83 0 0 Skylight - Dual Glaze Whole House 5 Skylight Front (North) 4.0 0.700 0.83' 0 0 Skylight - Dual Glaze Whole House 6 Skylight Front (North) 4.0 0.700 0.83 0 0 Sight - Dual Glaze Whole House Z Window Front (North) 40.0 0.740 0.37 0 90 Summit 5500 Al DP Low E Whole House 8 Window Left (East) 30.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Whole House 5 Window Left (Fast) _ 12.7 0.610 0.39 90 90 Summit 5500 Al DP Low E Whole House 1Q Window Left (East) 30.0 0.610 0.39 90 90 Summit 5500 Al DP Low E Whole House " Window Rear (South) 48.0 0.740 0.37 180 90 Summit 5500 Al DP Low E Whole House 12 Window Rear South 12.0 0.600 0.37 180 90 Summit 5500 Al DP Low E Whole House j_3_ Window Left (East) 480 0.740 0.37 90 90 Summit 5500 Al DP Low E Whole House 14 Window Rear (South) 7.5 0.460 0.37 180 90 Summit 5500 At DP Low E Whole House 15 Window Rear (South) 16.0 0.620 0.38 180 90 Glass Block Whole House 16 Window Rear South 9.0 0.620 0.38 180 90 Glass Block Whole House 17 Window Right (West) 6.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Whole House 18 Window Right _(West) 24.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Whole House -12 Window Right (West) 24.0 0.610 0.39 270 90 Summit 5500 Al DP Low E Whole House INTERIOR AND EXTERIOR SHADING Window Overhanq Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 None 1.00 7 Bug Screen 0.76 8 Buq Screen 0.76 9 10 11 12 13 14 15 16 17 18 T9 - Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Bug Screen Screen .Bug Bug Screen 0.76 0.76 0.76 8.0 6.0 0.76 6.0 2.0 0.76 8.0 6.0 0.76 0.76 0.76 0.76 0.76 0.76 10.0 0.1 10.0 10.0 10.0 0.1 10.0 10.0 10.0 0.1 10.0 10.0 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:8 of 15 1 Comauter Method Summary (Part 3 of 3) C -2R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Type (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments Concrete, Heavyweight 1,192 3 sn _28 0"98 n/a Whole House / Slab on Grarfe Concrete, Heavyweight 623 3_50 28 0_98 n/a 2 Whole House / Slab on Grade PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 169 0.76 0.0 0 Whole House Slab Perimeter 21 0-76 0.0 D Whole House HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC System Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 12.0 SEER Ducts in Attic 4.2 Setback HVAC System WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FGR -50-240 Small Gas Standard 1 38,000 50 0.60 n/a n/a 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. Run Initiation Time: 10/19/0404:44:25 Run Code: 1098186265 Ener Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1295 Pa e:9 of 15 Computer Method Summary (Addendum) C -2R MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3ased on the adequacy of the special justitication and documentation submitted. Plan I Field The HVAC System "HVAC System" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HIGH MASS Design(see C -2R) -Verify Thermal Mass: 1182 sgft Exposed Slab Floor, 3.50" thick at Whole House HIGH MASS Design(see C -2R) - Verify Thermal Mass: 623 sgft Covered Slab Floor, 3.50" thick at Whole House HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan Field The HVAC System "HVAC System" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verifification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC System" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. Run Initiation Time: 10/19/04 04:44:25 Run Code: 1098186265 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page: 10 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE MALIBU DS - (Complies in 4 -Cardinal Directions 10/19/2004 SYSTEM NAME FLOOR AREA HVAC System 1.805 KS Number of Systems 1 Heating System Output per System 65,000 Total Output (Btuh) 65,000 Output (Btuh/sgft) 36.0 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sgft) 32.7 Total Output (sgft/Ton) 367.1 Air System CFM per System 1,400 Airflow (cfm) 1,400 Airflow (cfm/sgft) 0.78 Airflow (cfm/Ton) 284.7 Outside Air (%) 0.0 Outside Air (cfm/sgft) 0.00 Note: values above given at ARI conditions 26.0 OF ?� Outside Air 0 cfm 68.9 of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible Latent CFM I Sensible 1,674 32,060 2,729 716 32,161 0 1,603 1,608 0 0 0 0 0 0 0 0 0 1,603 1,608 35,266 2,729 35 378 YORK DlNH060NO6506 40,385 13,178 65,000 Total Adjusted System Output 40,385 13,178 65,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am 68.9 OF 68.9 OF n 112.20F Supply Fan Heating Coil 1400 cfm h Return Air Ducts "I Supply Air Ducts 111.1oF ROOMS 70.0 of I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 111.0 / 77.6 of 79.1 / 66.0 of 79.1 / 66.0 of 60.0 / 58.9 of Supply Air Ducts Outside Air O' 0 cfm Supply Fan Cooling Coil 61.1 / 59.3 of 1400 cfm 52.4% R.H. ROOMS 79.1/66.0 of ri 78.0 / 65.7 of 3.1 User Number: 5454 Return Air Ducts Job Number: 3.1-1295 1of15 ROOM LOAD SUMMARY PROJECT NAME MALIBU DS - (Complies in 4 -Cardinal Directions DATE 10/19/2004 SYSTEM NAME HVAC System FLOOR AREA 1,805 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Whole House Whole House 1 1,674 32,060 2,729 1,674 32,060 2,729 716 32,161 PAGE TOTAL 1 1,674 32,060 2,729 716 32,161 TOTAL 1 1,674 32,060 2,729 716 32,161 EnergyPro 3.1 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page:12 of 15 ROOM HEATING PEAK LOADS Project Title Date MALIBU DS - (Complies in 4 -Cardinal Directions 110/19/2004 Room Information Desi n Conditions Room Name Whole House Time of Peak Jan 12 am Floor Area 1,805 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value Z�T of Btu/hr IR -13 Wall w/1" EPS I 1,781.0 . X X X X X X X X X X x x X X X X X X X X X X X x X X X X X X X X X X X X X X X 0.0280 x X X X X X X X X X x x X X X X X X X X X X X X X X X X X X X X X X X X X X X 44.0 = = = = = = = = = = = = = = = = 2,195 24.0 0.7000 44.0 739 perimeter = 190.3 44.5 8,468 1,358.8 0.0585 44.0 3,498 24.0 0.3872 44.0 409 136.0 0.7400 44.0 4,428 126.7 0.6100 44.0 3,401 12.0 0.6000 44.0 317 7.5 0,4600 44.0 152 25.0 0.6200 682 213.0 0.0885 44 Q 829 nems shown with an asterisk (-) denote conduction through an interior surtace to another room. Page Total: 25,118 Infiltration: F 1.00 X 1.064 X 1 805 X 10.00 X 0.50 / 6] X 0 = 7 043 chedule Alr Sensible Area Ceiling Height ACH ILT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 32,161 EnergyPro 31 By EnergySoft User Number: 5454 Job Number: 3.1-1295 Page: 13 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY MALIBU DS =(Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Whole House 780F 112°F 340E Conduction Area ' U -Value DETD 1 Btu/hr X (Skylight) 51.0 = 2,544 X Sk i ht 34.0 = 571 X (Skylight) 30.6 = 2,433 X Window 4032 XO 30.6 = 284 X 152 34.0 = 3 422 X 4.0 34.0 = 2.628 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 12 771 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Sk i ht (Skylight) (Skylight) Skylight (Skylight) Sk i ht (Skylight) Skylight (Skylight) Skviiaht (Skylight) Window 2680 2 FR DR (North) Window 5060 XO (East) Window 4032 XO (East) Window 5060 XO East ( 0.0 X1 x X x x X x x X x + + + + + + + + + + 4.0 x X x X X x X x X x 152)X x ) X x X )x 0.954 = = = = = = = = __ = 580 ( 0.0 1 4.0 152) 0.954 580 ( 0.0 1 4.0 152 0.954 580 ( 0.0 1 4.0 152)x 0.954 580 ( 0.0 1 4.0 152) 0.954 580 ( 0.0 1 4.0 152)X 0.954 580 ( 0.0 1 40.0 15) 0.412 247 ( 0.0 1 30.0 73)x 0.434 951 ( 0.0 1 12.7 73)X 0.434 403 ( 0.0 1 30.0 I 0.434 951 Sched. Page Total 6 032 Internal Gain Frac. Area' Heat Gain Btu/hr Lights 1.00 x 1,805 X 0.500 Watts/sgft x 3.41 BtuhfWatt = 3,080 Occupants 1.00 X 1,805 X 245 Btuh/OCC. / 333 sgft/occ. = 1,328 Receptacle 1.00 x 1 805 x 0.000 Watts/sqft x 3.413 Btuh/Watt = 0 Process 1.00 x 1,805 X 0.000 Watts/sgft x 3.412 Btuh/Watt = o Infiltration: x x 8Il x x / 60] _ Schedule . Air Sensible Area Ceiling Height ACH 4,1T Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,0601 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occu ants 1.00 x 805 X 155 Btuh/OCC. / 333 sgft/occ. = 840 Receptacle 1.00 x 1 805 x 0.000 Watts/sqft x 3.41 Btuh/Watt = 0 Process 1.00 x 805 x 0.000 Watts/sqft x 3.41 Btuh[Watt = o Infiltration: 1.0o X 4 77 x 1 80 x 10.00 x 0.50 / 60] 0.00263 = 1 889 chedule Air Latent Area Ceiling Height ACH DW Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,729 Energ Pro 3.1 By Ener Soft User Number: 5454 Job Number: 3.1-1295 Pa e:14 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY MALIBU DS - (Complies in 4 -Cardinal Directions) 10/19/2004 Project Title Date Room Name Whole House Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 1120 F Design Temperature Difference: 340F Conduction Area X U -Value Btu/hr 577 1. Design Equivalent Temperature Difference (DETD) , Page Total 577 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr Window 3080 2 FR DR (South) Wondnvv 217160 SH (South) Window 3080 2 FR DR _(East) Window 1016 FO 5 (South) Window 4040 GL BLK (South) Window 3030 GL BL (South) Window 3020 XO Window 4060 XO (West) (West) Window 4060 XO (West) . 74 ( 47.4 ( 48.0 X1 X x X x x x x x + + + + + + + + + + 0.0 x x x x x X x X X x 32 ) X x x x x X X X ) x )x 0.41 = = = = = = = = __ = 297 ( 12.0,X 1 0.0 32) 0.412 74 ( 47.4 1 0.6 73) 0.41 311 ( 0.0 1 7.5 32) 0.41 99 ( 0.0 1 16.0 32) 0.423 217 ( 0.0 1 9.0 32) 0.423 122 ( 0.0 1 6.0 73) 0.434 190 ( 0.0 1 24.0 73) 0.434 761 ( 0.0 1 24.0 7 0.434 761 ( _ _ Sched: Page Total 2.8301 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 x 1,805 X 0.50C Wafts/sgft x 3.41 Btuh/Watt = 3,080 Occupants 1.00 X 1,805 X 24 Btuh/OCC. / 333 sgft/OCc. = 1,328 Receptacle 1.00 x 1,805 x O.00C Watts/sgft x 3.413 Btuh/Watt - 0 Process 1.00 x 1,805 x O-OOC Watts/sgft x 3-413 Btuh[Watt = 00 Infiltration: [� x � x g0 x x � / 60] Schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 32,060-1 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 1 805 x 155 Btuh/OCC. I 333 sgft/OCC.= 8 0 Receptacle 1.00 x 1 805 x 0.000 Watts/sgft X 3.41 Btuh/Waft = '0 Process ( 1.00 x 1 805 x 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: I 1.00 x 4 77 x 1 80 x 10.00 x 60] 0.00263 = 1 889 chedule Air Latent Area Ceiling Height ACH �yy Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,729 Ener Pro 3.1 By Energ Soft User Number: 5454 Job Number: 3.1-1295 Page:15 of 15