BFE2014-108878-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
c&ty/ 4 4wQ"
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT
Application Number:
BWFE2014-1088
Property Address:
So_ (p e>5 –evA
APN:
776330006
Application Description:
266 LF 6' PERIMETER WALL AND RETAINING
Property Zoning:
Application Valuation:
$6,500.00
Applicant:
MARK A TEMPLE CONSTRUCTION INC
699 INDIAN TRAIL
PALM SPRINGS, CA 92264
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: 430358
Date: 1/� -e�1 /% Contractor:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the
applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon, and
who contracts for the projects with a contractor(s) licensed pursuant to the Contractors'
State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153-
Date:
77-7153
Date: 10/2/2014
Owner:
29TH STREET CITRUS PROJECT
1010 ANDREAS PALMS
PALM SPRINGS, CA 0
Contractor:
MARK A TEMPLE CONSTRUCTION INC
699 INDIAN TRAIL
PALM SPRINGS, CA 92264
(760)323-5310
Llc. No.: 430358
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance of
the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: _ Policy Number: _
_ I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith
comply with those provisions.
Date: /y —�O� Applicant: M
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE 15 UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE
HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to enter upon the above-
mentioned property for inspection purposes. r
Date: Z221 ZU 2!!1/-- Signature (Applicant or Agent)
DESCRIPTION
AMOUNT
PAID
PAID DATE
FINANCIAL INFORMATION
ACCOUNT
QTY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $1.00 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
WALL/FENCE - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for FENCE OR FREESTANDING WALL $108.77 $0.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RET WALL <=12 - EA ADD 50 LF
101-0000-42404
0
$29.00
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RET WALL <=12 - FIRST 100 LF
101-0000-42404
0
$47.86
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RET WALL <=12 - FIRST 100 LF PC
101-0000-42600
0
$60.91
$0.00
PAID BY
METHOD
RECEIPT #
CHECK #
CLTD BY
Total Paid for RETAINING WALL $137.77 $0.00
TOTALS: $247.54 00
Description: 266 LF 6' PERIMETER WALL AND RETAINING
Type: WALL/FENCE Subtype: Status: APPROVED
Applied: 9/23/2014 SKH
Approved: 9/23/2014 SKH
Parcel No: 776330006 Site Address: ,CA
Subdivision: TR 32068 Block: Lot: 6
Issued:
Lot Sq Ft: 0 Building Sq Ft: 0 Zoning:
Finaled:
Valuation: $6,500.00 Occupancy Type: Construction Type:
Expired:
No. Buildings: 0 No. Stories: 0 No. Unites: 0
CA
Details: 266LF OF 6' GARDEN AND RETAINING WALL AT NORTH, EAST AND SOUTH PROPERTY LINES, (29LF 5' WALL W/1' RETAINING, 118LF
OF 12'-18" RETAINING WALL, 33LF OF 3' WALL W/1' RETAINING, 82LF OF 6' WALL, 4LF OF 1' WALL W/1' RETAIN ING)[ANGELUS
SPECIFICATIONS] PRECISION CONCRETE BLOCK SHALL BE COVERED WITH STUCCO, PAINT, OR TEXTURED COATING WHERE VISIBLE
FROM OUTSIDE THE PROPERTY. 2013 CALIFORNIA BUILDING CODES.
Applied to Approved
NAME TYPE NAME
ADDRESS1
CITY
STATE
ZIP
PHONE
FAX
EMAIL
APPLICANT MARK A TEMPLE CONSTRUCTION
INC
699 INDIAN TRAIL
PALM SPRINGS
CA
92264
CONTRACTOR MARK A TEMPLE CONSTRUCTION
INC
699 INDIAN TRAIL
PALM SPRINGS
CA
92264
OWNER 29TH STREET CITRUS PROJECT
1010 ANDREAS PALMS
PALM SPRINGS
CA
0
Printed: Thursday, October 02, 2014 3:57:46 PM 1 of 3 CLT
[V[TFM [
Permit Details PERMIT NUMBER
r ~ City of La Quinta BWFE201%mt-Kl'0 8
Printed: Thursday, October 02, 2014 3:57:46 PM 2 of 3
CVCTFMG
LTD
CBY
DESCRIPTION
ACCOUNT
QTY
AMOUNT
PAID
PAID DATE
RECEIPT #
CHECK #
METHOD
PAID BY
BOND BEAM
FINAL"
BY
BSAS SB1473 FEE
101-0000-20306
0
$1.00
$0.00
Total Paid for BUILDING STANDARDS ADMINISTRATION
$1.00 $0.00
BSA:
WALL/FENCE - FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
WALL/FENCE - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for FENCE OR FREESTANDING WALL $108.77 $0.00
RET WALL <=12 - EA
101-0000-42404
0
$29.00
$0.00
ADD 50 LF
RET WALL <=12 - FIRST
101-0000-42404
0
$47.86
$0.00
100 LF
RET WALL <=12 - FIRST
101-0000-42600
0
$60.91
$0.00
100 LF PC
Total Paid for RETAINING WALL $137.77 $0.00
TOTALS:i0
Printed: Thursday, October 02, 2014 3:57:46 PM 2 of 3
CVCTFMG
INSPECTIONS
SEQID
INSPECTION TYPE
INSPECTOR
SCHEDULED
DATE
COMPLETED
DATE
RESULT
REMARKS
NOTES
BOND BEAM
FINAL"
FOOTINGS
Printed: Thursday, October 02, 2014 3:57:46 PM 2 of 3
CVCTFMG
�i�'�'.,. '' "s.
�v A.
cFtr OF TW"" Y -
Printed: Thursday, October 02, 2014 3:57:46 PM 3 of 3
��CYC TFMC
d4
B*SUI�z94;4IHC-
ANGELUS
BLOCK MASONRY FENCE WALL SYSTEM
e. _: 13: _
6' High Wall 2' to 4' Retaining
Toe -out Footing - C o 100mph (ult)
Risk Category I
678" Wide CMU
I. DESIGN CRITERIA PER 2013 CBC
?. ALLOWABLE SOIL BEARING PRESSURE = 1500psf
S. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf
I. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf
i. CANTILEVER ACTIVE = 30pcf NO SURCHARGE
i. MASONRY COMPRESSIVE STRENGTH, f m = 1500psi. SPECIAL INSPECTION
NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY.
USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE
PROJECT SPECIFIC SITE.
10TES:
I. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615
GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24
INCHES, WHICHEVER IS GREATER. CENTER VERTICAL BARS IN CELLS. U.O.N.
?. JOINT REINFORCEMENT (-LADDER" TYPE) SHALL BE COLD—DRAWN STEEL
WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES.
S. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi ® 28 DAYS, UNLESS
OTHERWISE REQUIRED BY SOILS REPORT.
F.. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS
BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR
WITHOUT MORTARLESS HEAD JOINTS (TONGUE—AND-GROOVE), OR
ANGELUS BLOCK SLUMPSTONE SHALL BE USED.
i. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS
MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPORTIONS AND
REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS
MANUFACTURED BY E—Z MIX INC., CONFORMING TO PROPERTY
REQUIREMENTS OF ASTM C270.
i. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP,
AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF
'OOpsi. '2_000 P5;
. ,rtST COURSE MAY BE WET—SET 1 1/2 INCHES MAX. WHILE CONCRETE
IS PLASTIC. '
3. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH
VERTICAL CONTINUITY OF THE CELLS.
). VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF
40'-0"o.c. OR 20'—O"o.c. IF WALL IS TO BE STUCCO COATED OR
MORTAR WASHED
). GROUT ALL CELLS WITH REINFORCEMENT.
I. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE AND ALL
FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL .
REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT.
>.. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK—OUT DETAILS
SEE DETAIL SHEET S-5.1.
S. DO NOT PLACE FOOTING WITHIN 5'-0" OF A SLOPE
LOADING
2
SEISMIC, 5
ACCELERA'
FOUNDATIC
MAXIMUM
LOADING.
ANDERSON DESIGN GROUP
Structural Engineering Building Design
228 East Badillo Street • Covina • CA • 91723-2115
(626) 938-1595 Facsimile (626) 938-0485
englnecring excellence since 1957'
OPTIONAL WALL CAP
11 1 ' OF iA C UINTA
BUIE_ ING & S-3AFE•iY DEPT.
6 .STD. LADDER TYPE
MASONRY FENCE WALL SCHEDULE
REINF.WALL STEM 'X' BARS
V MAX. TYPE PER S-2.0 16" LONG CMU
B' MIN.
C'
2'-0"
'A'
'B'
4024"o.c.
4®32"o.c.
3'-3"
2'-3"
0'-7"
0'-2-
w
w/ VERT. REINF. - O1dNDAT40N_
024'o.c. (16" LONG CMU)
SCHEDULE, LAP
® CTR. OF WALL
GROUT CELLS .w/ REINF. lo
'A'
4®24"o.c.
3'-6"
0'-9"
2'-8"
'B'
4®32"o.c.
2'-3"
0'-5"
1c.f. 3/4" GRAVEL WRAPPED IN WELL GRADED, CLEAN
MIRAFI 140N FILTER FABRIC—SANDS OR GRAVEL OR
SLOPE TO DRAIN. WATERPROOF COC BINA
#4 CONT. r•
3'-4"
'A'
B'
4016"o.c.
4032"o.c.
S-6"
2'-6"
1'-0"
0'-9"
#4 CONT. ® 12"o.c. —
CONT. CONC. FTG.
A.
4®16"o.c. 1
3'-9"
1'-4"
0"A
'B'
4032"o.c.
2'-10"
1'-2"
LOADING
2
SEISMIC, 5
ACCELERA'
FOUNDATIC
MAXIMUM
LOADING.
ANDERSON DESIGN GROUP
Structural Engineering Building Design
228 East Badillo Street • Covina • CA • 91723-2115
(626) 938-1595 Facsimile (626) 938-0485
englnecring excellence since 1957'
OPTIONAL WALL CAP
11 1 ' OF iA C UINTA
BUIE_ ING & S-3AFE•iY DEPT.
6 .STD. LADDER TYPE
(#5 STD FOR'SLUMPST NE)„—
JOINT REINF. AT TOP CURSE, NSTRUCTION
ft2410UT'!CE
AT FIRST COURSE, AND 24' o.c.
AT FENCE 12”
Lj
tJAI ms TO EDGE OF
WIDE (NOM.) CMU. N ARE T`ADIACEiJi
rFOBLVVERT LOCK TO
w
w/ VERT. REINF. - O1dNDAT40N_
024'o.c. (16" LONG CMU)
SCHEDULE, LAP
® CTR. OF WALL
GROUT CELLS .w/ REINF. lo
114 O
I
X
io
w
#4 HORIZ. 024"o.c.
® RETAINING' OPTIONAL CHAMFER
WET—SET FIRST _
4.0 SDR .35 PERF. PIPE w/ BACKFILL-
1c.f. 3/4" GRAVEL WRAPPED IN WELL GRADED, CLEAN
MIRAFI 140N FILTER FABRIC—SANDS OR GRAVEL OR
SLOPE TO DRAIN. WATERPROOF COC BINA
#4 CONT. r•
BACKSIDE OF RETAINING WALL IOR SWO ,SP
8" WIDE (NOM.) CMU
TVQ
FULLY GROUTED
ft2410UT'!CE
FACE
Lj
X'BARS PER
rFOBLVVERT LOCK TO
w
SCHEDULE, LAP
24". MIN.
N
F.G.
w
Q_
WET—SET FIRST _
COURSE
#4 CONT. r•
N
#4 CONT. ® 12"o.c. —
CONT. CONC. FTG.
3" CLR.
CONC. KEY
TYP
12" 1 12"
' B' MIN.
DATE SIGNED 6-25-14
S-1.5LQ
#625
��i►�.c l or 2
d)VL . *�.'s:rC
BLOCK CO, INC.
Since 1946
ANGELUS BLOCK MASONRY FENCE WALL SYSTEM
END OF WALL
x O 5 x HF,
OO
X
Ln
5 X HF
z
o
\A
8' High Max. Site Wall
C ® 100mph
Risk Category I
6" Wide CMU
5 x-11
------------
A
'NTA
QU
FETY DEPT.
,- j
FOP,", ONSTRUCTION
11B
A
RETURN TYP.
5 x Hir O r5 x HFt
TYPICAL REINFORCED WALL STEM TYPES PLAN
WALL TYPES
G) &
TOTAL WALL LENGTH
5 x Hc- MIN.
TYPICAL
WALL TYPES rj
ANDERSON -DESIGN GROUP
Structural Engineering Building Design
228 East Badillo Street • Covina a CA * 91723-2115
(626) 938-1595 Facsimile (626) 938-0485
"-91—,ing excellence since 1957'
5 x HF MIN. I
CA-T-&RGNED 5-21-14
S -2.0 -LQ
If4255
BLOCK C1 suO., INC.
sl+�.
ANGELUS BLOCK MASONRY FENCE WALL SYSTEM
6' to .8' .High Site Wall
Spread Footing - C o 100mph (ult.)
Risk Category I
6' Wide CMU
IESIGN CRITERIA:
I. DESIGN CRITERIA PER 2013 CBC
FENCE WALL SCHEDULE
?. ALLOWABLE SOIL BEARING PRESSURE = 1500psf
OPTIONAL WALL CAP
S. ALLOWABLE SOIL PASSIVE PRESSURE = 150pcf
'X' BARS
1. COEFFICIENT OF FRICTION = 0.25, COHESION = Opsf
GROUT CELLS
i. CANTILEVER ACTIVE = 30pcf
B' MIN.
i. MASONRY COMPRESSIVE STRENGTH, f'm = 1500psi. SPECIAL INSPECTION
w/ REINF.
NOT REQUIRED PER CBC SECTION 1704.2, EXCEPTION 2, 'U' OCCUPANCY.
18" LONG CMU
�. USER TO VERIFY APPLICABILITY OF THE DEFINED DESIGN CRITERIA FOR THE
PROJECT SPECIFIC SITE.
#6 STD. LADDER TYPE
40TES:
(#5 STD FOR SLUMPSTONE)_
BUILD{f�1 i `AFETY DEPT.
JOINT REINF. AT TOP COURSE,
I. REINFORCING STEEL SHALL BE DEFORMED AND CONFORM TO ASTM A615
AT FIRST COURSE, AND 24"o.c.
GRADE 60. PROVIDE SPLICES (LAPS) OF 48 BAR DIAMETERS OR 24
INCHES, WHICHEVER IS GREATER. CENTER VERTICAL .BARS IN CELLS.
B'
?. JOINT REINFORCEMENT ("LADDER' TYPE) SHALL BE COLD -DRAWN STEEL
.MASONRY
FENCE WALL SCHEDULE
WIRE CONFORMING TO ASTM A951. PROVIDE MINIMUM 6 INCH LAP SPLICES.
6" WIDE (NOM.) CMU!..
�' MAX.
'X' BARS
RONF.WALL STEM
GROUT CELLS
L' STEM
B' MIN.
5. STRENGTH OF CONCRETE FOR FOOTINGS = 2500psi 0 28 DAYS, UNLESS
w/ REINF.
iIA A
18" LONG CMU
OTHERWISE REQUIRED BY SOILS REPORT.
�
#48948"o.c.
#4054"o. c.
A'
BUILD{f�1 i `AFETY DEPT.
027"o.c.
1. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90. ANGELUS
2'-10"
BLOCK PRECISION, SPLIT FACE, BURNISHED, OR SHOTBLAST, WITH OR
B'
APF. y ���®
w
WITHOUT MORTARLESS HEAD JOINTS (TONGUE -AND -GROOVE), OR
ANGELUS BLOCK SLUMPSTONE SHALL BE USED.
FOR C TRUCTION a
Li
3. MORTAR SHALL BE SPEC MIX TYPE S PREBLENDED MASONRY MORTAR AS
'X' BARS PER
6'-8"
w
MANUFACTURED BY E -Z MIX INC., CONFORMING TO. PROPORTIONS AND
SCHEDULE ®
_
Of
REQUIREMENTS OF ASTM C270, OR SPEC MIX IWR MASONRY MORTAR AS
CTR. OF WALL
DAT B ��
a
MANUFACTURED BY E -Z MIX INC., CONFORMING T0, PROPERTY
B'
4048"o.c.
054"o.c.
REQUIREMENTS OF ASTM C270.
1'-11"
3. GROUT SHALL CONFORM TO ASTM C476, WITH AN 8-11 INCH SLUMP,
AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF
7'-4"
#4®48"o.c.
'OOpsi. 2000 p5 i
'Y'
4016"o.c.
4®18"o.c.
S-0"
BARS PER
..RST COURSE MAY BE WET -SET 1 1/2 INCHES MAX. WHILE CONCRETE
SCHEDULE LAP
w
4045"o.c.
IS PLASTIC.
PER 'L'
0
3. CONCRETE BLOCK SHALL BE LAID IN RUNNING BOND PATTERN WITH
z o
LLi
EQ' EQ' z :
VERTICAL CONTINUITY OF THE CELLS.
F.G.
N
#4®40"o.c.
3. VERTICAL CONTROL JOINTS SHALL BE SPACED AT A MAXIMUM OF
a
4099"o.c.
40'-O"o.c. OR 20'-O"o.c. IF WALL IS TO BE STUCCO COATED OR
WET -SET FIRSTbit
MORTAR WASHED
COURSE .
r
4®36'o.c.
). GROUT ALL CELLS WITH REINFORCEMENT.
2-#4 CONT.
iv
1. INSPECTIONS: A. AFTER FOOTING IS READY FOR CONCRETE .AND ALL
—
FOOTING REINFORCING IS TIED IN PLACE. B. AFTER VERTICAL
REINFORCEMENT IS IN PLACE AND CELLS ARE READY FOR GROUT.
2. FOR TYPICAL FOOTING STEP AND DRAINAGE BLOCK-OUT DETAILS
CONT. CONC. FTG.
3" CLR.
SEE DETAIL SHEET S-5.1.
TYP•
5. DO NOT PLACE FOOTING WITHIN 5'70" OF A SLOPE
ALT. BENDS
8' MIN.
PER SCHEDULE
ANDERSON DESIGN GROUP
Structural Engineering Building Design
4*4p 228 East Gadillo Street • Covina • CA • 91723-2115
(626) 938-1595 • Facsimile (626) 938-0485
engf^ee g exceffon sfn ]957'
PROFESS/
41
E 3 1
sqT lR C T &RP "
CA��FO
D TE SIGNED 6-25-14
S-1.OLQ
P1���2
.MASONRY
FENCE WALL SCHEDULE
�' MAX.
'X' BARS
RONF.WALL STEM
'Y' BARS
L' STEM
B' MIN.
16' LONG CMU 18" LONG CMU TYPE PER 5-2.0 16"
LONG CMU
18" LONG CMU
6'-0"
#48948"o.c.
#4054"o. c.
A'
4024"o.c.
027"o.c.
2'-0"
2'-10"
B'
4048"o.c.
®54"o.c.
2'-0"
6'-8"
#4®48"o.c.
#4®45"o. c.
A'
4016"o.c.
4(18"o.c.
2'-0"
B'
4048"o.c.
054"o.c.
2'-0"
1'-11"
7'-4"
#4®48"o.c.
#4045"o.c.
A
4016"o.c.
4®18"o.c.
S-0"
3'-6"
B'
4048"o.c.
4045"o.c.
2'-0"
2'-1".
8'-0"A'
#4®40"o.c.
#4®36"o. c.
4®8"o.c.
4099"o.c.
3'-4"
8'
40940"o.c.
4®36'o.c.
2'-0"
ANDERSON DESIGN GROUP
Structural Engineering Building Design
4*4p 228 East Gadillo Street • Covina • CA • 91723-2115
(626) 938-1595 • Facsimile (626) 938-0485
engf^ee g exceffon sfn ]957'
PROFESS/
41
E 3 1
sqT lR C T &RP "
CA��FO
D TE SIGNED 6-25-14
S-1.OLQ
P1���2
BLOCK CO., INC.
Since 19w8
ANGELUS BLOCK MASONRY FENCE WALL SYSTEM
,END OF WALL
U
x
/� SxHF
t
5xHF
8' High Max. Site Wall
C ® 100mph
Risk Category I
6" Wide CMU
5 F----•,
p U STA
r 0 x
"F3UCTION
o -
A
Y
�
RETURN TYP.
5 x HF /�1 5 x:HFT
TYPICAL REINFORCED WALL STEM TYPES PLAN
WALL TYPES O & O
5 x HF MIN.
TOTAL WALL LENGTH
TYPICAL REINFORCED WALL STEM TYPES ELEVATION
WALL TYPES O & O II
ANDERSON DESIGN GROUP
Structural Engineering Building Design
228 East Badillo Street • Covina • CA . 91723-2115
(626) 938-1595 • Facsimile (626) 938-0485
Mw engine—Ing excerrence since 2957-
5 x HF MIN.
AzWi,.�tGNED 5-21-14
S-2.OLQ
Pim 2 of 2
B`;#
City of La Quanta
-Building &r Safety Division
P.O. Box 1504, 78-495 Calle Tampico .
La Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
Permit #
5,LfE-2,014-1(Z
Project Address:
5668--6 491, 8
Owner's Name: �� �S lJ 2 t �•
A. P. Number: . ? 66 .— 330 — D 06
Address: 6 - �
Legal Description: L p� (j TSG 302 06 D
City, ST, Zip:/y `.� /' t S 64
Contractor: I As 1
/�l L•c/ S
/ .2
etc h ne: 3
T o t:�
P O
Address: � ,� i � / 2.'
Project Description:
a /
City,ST,Zip= {f �. r1✓� S1 CA
Telephone: � b 3
: '
State Lie. # : 3 U 3 5 $
City Lie. #,
e► v Gem t. S
Arch., Engr., Designer:
_ GOF
Ile
Address:
City., ST, Zip:
Tel
Telephone: —
ep
`:::» ::_>r :>::>;:s: <:<:':>:;;%: i':':i:<:=:: =:
Oc-> an
Construction Type: � v p cy:
State Lie.#
- is^Y�if
-
Project 'cttyP (circlea one): New Addn Alter Repair r Dem o
Name of Contact Person: fil'04 �� e
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person: 6 0 3S�C)
Estimated Value of Project: t Sb
< O - r Lt 3.Zf Ll APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
Rcq'd
Rec'd
TRACEING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Calcs.
Reviewed, ready for corrections
Plan Check Deposit
Truss C21cs.
Caned Contact Person
Plan Check Balance
Title 24 Cales.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2°" Review, ready for correctionsrssue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Decd
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN I10USE:-
'`d Review, ready for correctionsfissue
Developer Impact Fee
Planning Approval
Called Contact Person
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees