07-1199 (RER)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: 07-00001199
Property Address: 81645 BROWN DEER PARK
APN: 767-540-001- - -
Application description: REMODEL - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 6300
Applicant: Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
4.
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals C de, and my License is in full force and effect.
Licen
Date: P 0 ontractor: r
OWNER- ILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
( ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERAIIT
Owner:
EATON INV
Contractor:
B & M CONSTRUCTION
P.O. BOX 1977
LA QIIINTA, CA 92247
(760)578-0406
Lic. No.: 746760
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/26/07
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3706 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1542480-2006
I certify that, in the performance of the work for which this. permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should bec ane subject to th orkers' compensation provisions of Section
3700 of a Labor Code, �I forthwith com with those provisi nf
C� r
ate: ( a6 U Applicant:
WARNING: FAILURE TO SECURE WORKERS' COMPEN TION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building con truction, and hereby horize representatives
of this count to enter upon the above-mentioned property f pection pu�poses.
Date: -� ature (Applicant or Agent):
Application Number . . 07-00001199
Permit . . . BUILDING PERMIT
Additional desc .
Permit.Fee . . . . 90.00
Plan Check
Fee
58.50
Issue Date . . . .
Valuation
. . .
. 6300
Expiration Date 10/23/07
Qty Unit. Charge Per
Extension
BASE FEE
45.00
5.00 9.0000 THOU BLDG 2,001-25,000
45.00
----------------------------------------------------------------------------
Special Notes and Comments
CLOSE IN (2) DOUBLE FRENCH DOORS AND
ADD ONE 6X4 WINDOW.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . ENERGY
REVIEW FEE
5.85
STRONG
MOTION (SMI)
- RES
.63
Fee summary Charged Paid
-------------------------------------
Credited
----------
----------
Due
Permit Fee Total 90.00
.00
.00
90.00
Plan Check Total 58.50
.00
.00
58.50
Other Fee Total 6.48
.00
.00
6.48
Grand Total 154.98
.00
.00.
154.98
LQPEFNIIT
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... 81-645 Brown Deer P1. Date..10/05/03 16:21:38
Project Address........ 81-645 Brown Deer Pl. ******* ---------------------
La Quinta *v6.01* I I
Documentation Author... Dawne Carsen Hallock ******* I Building Permit # I
Energy Management Group, Inc. I 1
69-115 Ramon Rd., #F1364 I Plan Check / Date I
Cathedral City, CA 92234 I 1
760-772-3642 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
--------------------------------=----------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM CF -1R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
Glazing Percentage.........
Average Glazing U -factor....
Average Glazing SHGC.......
Average Ceiling Height.....
3805 sf
Single Family Detached
Existing Plus Addition
Front Facing 0 deg (N)
1
1
Slab On Grade
21.7 % of floor area
0.49 Btu/hr-sf-F
0.56
10.6 ft
BUILDING SHELL INSULATION
-------------------------
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPFill OVED
FOR CONSTRUCTION
DATE} 6!B 03
4�'1G6'
Component Frame Cavity Sheathing Total Assembly
Type Type R -value R -value R -value U -factor Location/Comments
------------------------------------------------- ------------------------
Wall Wood R-17.8 R-0 R-17.8 0.065
Roof Wood R-11 R-19 R-30 0.031 Attic
Door None R-0 R-0 R-0 0.330 Solid Wood
SlabEdge None R-0 R-0 F2=0.760 To Outside
SlabEdge None R-0 R-0 F2=0.510 To Garage, To closet
FENESTRATION
------------
Over
Area U- Exterior hang/
Orientation (sf) Factor SHGC Shading Fins Location/Comments
---------------- ------------------------- ----- --------------------------
Wind Front (N) 52.0 0.496 0.560 Standard Yes Vinyl/Wood Fixed
Door Front (N) 72.0 0.490 0.560 Standard Yes Vinyl/Wood Patio Door
Door Front (NE) 20.0 0.490 0.560 Standard Yes Vinyl/Wood Patio Door
Wind Left (E) 8.0 0.490 0.560 Standard Yes Vinyl/Wood Operable
Wind Left (E) 20.0 0.500 0.410 Standard None Glassblock
Wind Left (E) 103.0 0.490 0.560 Standard None Vinyl/Wood Operable
Door Left (E) 40.0 0.490 0.560 Standard Yes Vinyl/Wood Patio Door
Wind Back (S) 39.0 0.490 0.560 Standard None Vinyl/Wood Operable
Door Back (S) 176.0 0.490 0.560 Standard Yes Vinyl/Wood Patio Door
r
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM CF -1R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
------------------------------=------------------------------------------------
FENESTRATION
------------
19:10101 P:11MuP.Ivl.
Area
Thickness
Type
------------
Exposed
--------------
Over-
(in)
---------
Location/Comments
S1abOnGrade
Yes
2100
Area
U-
SlabOnGrade
Exterior
hang/
3.5
Covered
Orientation
Yes
(sf)
Factor
SHGC
Shading
Fins
Location/Comments
----------------
Wind
Back
(S)
-----
46.0
------
0.490
------
0.560
--------
Standard
-----
Yes
---- ----------------------
Vinyl/Wood
Fixed
Wind
Back
(SW)
36..0
0.490
0.560
Standard
None
Vinyl/Wood
Fixed
Door
Back
(SW)
20.0
0.490
0.560
Standard
Yes
Vinyl/Wood
Patio Door
Wind
Right
(W)
82.0
0.490
0.560
Standard
Yes
Vinyl/Wood
Operable
Door
Right
(W)
112.0
0.490
0.560
Standard
Yes
Vinyl/Wood
Patio Door
19:10101 P:11MuP.Ivl.
HVAC SYSTEMS
Area
Thickness
Type
------------
Exposed
--------------
(sf)
------
(in)
---------
Location/Comments
S1abOnGrade
Yes
2100
4.5
------------------------
Exposed
SlabOnGrade
No
977
3.5
Covered
S1abOnGrade
Yes
380
4.5
Covered
S1abOnGrade
Yes
348
4.5
Covered
HVAC SYSTEMS
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
------------ ----------- ------------------- ------
DHW
Storage Gas Standard 1
DHW1
Storage Gas Standard 1
Tank External
Energy Size Insulation
Factor (gal) R -value
-------- ------ ----------
0.62 30 R- n/a
0.62 70 R- n/a
Refrigerant
Tested
ACCA
Equipment
Minimum
Charge and Duct
Duct
Duct
Manual
Thermostat
Type
Efficiency
Airflow
Location
R -value
Leakage
D
Type
------------
Furnace
------------
0.780
AFUE
-------
n/a
-----------
Attic
-------
R-4.2
-------
No
------
No
----------
Setback
ACSplit
12.00
SEER
No
Attic
R-4.2
No
No
Setback
Furnace
0.780
AFUE
n/a
Attic
R-4.2
No
No
Setback
ACSplit
11.00
SEER
No
Attic
R-4.2
No
No
Setback
Furnace
0.780
AFUE
n/a
Attic
R-4.2
No
No
Setback
ACSplit
11.00
SEER
No
Attic
R-4.2
No
No
Setback
WATER HEATING SYSTEMS
---------------------
Number
in
Tank Type Heater Type Distribution Type System
------------ ----------- ------------------- ------
DHW
Storage Gas Standard 1
DHW1
Storage Gas Standard 1
Tank External
Energy Size Insulation
Factor (gal) R -value
-------- ------ ----------
0.62 30 R- n/a
0.62 70 R- n/a
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
I MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM CF -1R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a High Mass Design.
This building incorporates non-standard Water Heating System
REMARKS
CERTIFICATE OF COMPLIANCE:'RESIDENTIAL Page 4 CF -1R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM CF -1R I
User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features
Modeling Assumptions section.
DESIGNER or OWNER
Name.... Dick Reynen
Company. Broker
Address. P.O. Box 840
La Quinta, Ca
Phone... (760)964-1316
License.
DOCUMENTATION AUTHOR
Name.... Dawne Carsen Hallock
Company. Energy Management Group, Inc.
Address. 69-115 Ramon Rd., #F1364
92253 Cathedral City, CA 92234
Phone... 760-772-3642
Signed.. 10--0i-y3
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
Signed. .^'""�C' /0"S -0 -
(date)
CeN tiff ed I.Eno rgy Analyst
Dry vne Coregn
R 98=9:1-224
V. r
rr
A0EC
f C*,o°r:c Atc:.!unon of E-nergy Co:uutfw�
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
Project Address........ 81-645 Brown Deer Pl. ******* ---------------------
La Quinta *v6.01* 1 1
Documentation Author... Dawne Carsen Hallock ******* I Building Permit # I
Energy Management Group, Inc. j 1
69-115 Ramon Rd., #F1364 1 Plan Check / Date I
Cathedral City, CA 92234 I I
760-772-3642 I Field Check/ Date 1
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
---------- ----------
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM MF -1R 1
( User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. 1
-------------------------------------------------------------------------------
Note: Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents, the features noted shall be considered by all parties as
minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
--------------------------
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturer's labeled R -Value.
*150(c): Minimum R-13 wall insulation in wood framed walls or
equivalent U -factor in metal frame walls (does not apply
to exterior mass walls).
*i50(d): Minimum R-13 raised floor insulation in framed floors.
150(1): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets insulation quality
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
Exfiltration Controls
1. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
2. Fenestration products (except field fabricated) have
label with certified U -factor, certified Solar Heat Gain
Coefficient (SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets Commission quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and Gas Logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 6 MF -1R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM MF -1R I
I User#-MP0999. User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
--------------------------------------------------------------
Design- Enforce-
er ment
110-113: HVAC equipment, water heaters, showerheads and
faucets certified by the Commission.
150(h): Heating and/or cooling loads calculated in accordance
with ASHRAE, SMACNA or ACCA.
150(1): Setback thermostat on all applicable heating and/or
cooling systems.
150(j): Pipe and Tank insulation
1. Storage gas water heaters rated with an Energy Factor
less than 0.58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater.
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. Back-up tanks for solar system, unfired storage tanks, or
other indirect hot water tanks have R-12 external
insulation or R-16 combined internal/external insulation.
4. All buried or exposed piping insulated in recirculating
sections of hot water system.
5. Cooling system piping below 55 degrees insulated.
6. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and in-
sulated, to meet the requirements of the 1998 CMC sections
601, 603, and 604, and standard 6-3; ducts insulated to a
minimum installed level of R-4.2 or enclosed entirely
in conditioned space. Openings shall be sealed
with mastic, tape, aerosol sealant, or other duct -closure
system that meets the applicable requirements of UL181,
UL181A, or UL181B. If mastic or tape is used to seal openings
greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used. Building cavities shall not be used for
conveying conditioned air. Joints and seams of duct systems and
their components shall not. be sealed with cloth backed rubber
adhesive duct tapes unless,such tape is used in combination with
mastic and drawbands.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 7 MF -1R
Project Title.......... 81-645 Brown Deer P1. Date..10/05/03 16_:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM MF -1R I
User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
------------=------------------------------------------------------------------
resistance heating and no pilot light.
2. System is installed with:
a. At least 36 inches of pipe between filter and heater
for future solar heating.
b. Cover for outdoor pools or outdoor spas.
3. Pool system has directional inlets and a circulation
pump time switch.
115: Gas-fired central furnaces, pool heaters, spa heaters or
household cooking appliances have no continuously burning
pilot light (Exception: Non -electrical cooking appliances
with pilot < 150 Btu/hr).
LIGHTING MEASURES
-----------------
Design- Enforce-
er ment
150(k)l: Luminaires for general lighting in kitchens shall
have .lamps with an efficacy of 40 lumens/watt or greater
for general lighting in kitchens. This general Lighting
shall be controlled by a switch on a readily accessible
lighting control panel at an entrance to the kitchen.
150(k)2: Rooms with a shower or bathtub must have either at
least one luminaire with lamps with an efficacy of 40
lumens/watt or greater switched at the entrance to the
room or one of the alternatives to this requirement
allowed in Sec..150(k)2.; and recessed ceiling fixtures
are IC (insulation cover) approved.
COMPUTER METHOD SUMMARY Page 8 C -2R
Project Title.......... 81-645 Brown Deer P1. Date..10/05/03 16:21:38
Project Address........ 81-645 Brown Deer P1. ******* ---------------------
La Quinta *v6.01* 1 I
Documentation Author... Dawne Carsen Hallock ******* I Building Permit # I
Energy Management Group, Inc. I I
69-115 Ramon Rd., #F1364 I Plan Check / Date I
Cathedral City, CA 92234 i I
760-772-3642 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM C -2R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. 1
-------------------------------------------------------------------------------
-----------=----------------
----------------------------
MICROPAS6 ENERGY USE SUMMARY
= Energy Use
Standard
Proposed
Compliance =
_ (kBtu/sf-yr)
_-----------------------
Design
----------
Design
----------
Margin =
---------- _
= Space Heating..........
3.87
2.43
1.44 =
= Space Cooling..........
38.45
39.44
-0.99 =
= Water Heating..........
7.49
7.93
-0.44 =
= Total
49.81
49.80
0.01 _
_ *** Building complies
with Computer
Performance
GENERAL INFORMATION
Conditioned Floor Area..... 3805 sf
Building Type .............. Single Family Detached
Construction Type ......... Existing Plus Addition
Building Front Orientation. Front Facing 0 deg (N)
Number of Dwelling Units... 1
Number of Building Stories. 1
Weather Data Type.......... ReducedYear
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Glazing U -factor...
Average Glazing SHGC.......
Average Ceiling Height.....
Slab On Grade
3
40303 cf
3805 sf
21.7 % of floor area
0.49 Btu/hr-sf-F
0.56
10.6 ft
COMPUTER METHOD SUMMARY Page 9 C -2R
Project -Title .......... -81-645- Brown -Deer -Pl.
---_----_--Date..10/05/03-16_21_38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM C -2R I
User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
OPAQUE SURFACES
BUILDING
ZONE INFORMATION
Insul
Act
Solar
Form 3
Floor
-------------------------
# of
factor
R-val
Vent
Vent
Air
Comments
Area
Volume
Dwell
Cond-
Thermostat
Height
Area
Leakage
Zone Type
--------------
(sf)
-----
(cf)
-------
Units
-----
itioned
-------
Type
-----------
(ft)
-----
(sf)
--------
Credit
---------
LIVING
2
Wall
379
0.065
17.8
0
90
Residence
3077
33539
0.81
Yes
Setback
2.0
Standard
No
SLEEPING
Yes
W.19.2X6.16
11
Wall
425
0.065
17.8
Residence
380
3458
0.10
Yes
Setback
2.0
Standard
No
HOUSE
225
90
Yes
W.19.2X6.16
16
Wall
17
Residence
348
3306
0.09
Yes
Setback
2.0
Standard
No
OPAQUE SURFACES
Area
U-
Insul
Act
Solar
Form 3
Location/
Surface
(sf)
factor
R-val
Azm
Tilt Gains
Reference
Comments
--------------
LIVING -
------
Existing
-----
-----
---
---- -----
------------
----------------
1
Wall
192
0.065
17.8
0
90
No
W.19.2X6.16
2
Wall
379
0.065
17.8
0
90
Yes
W.19.2X6.16
7
Wall
771
0.065
17.8
90
90
Yes
W.19.2X6.16
11
Wall
425
0.065
17.8
180
90
Yes
W.19.2X6.16
14
Wall
97
0.065
17.8
225
90
Yes
W.19.2X6.16
16
Wall
17
0.065
17.8
270
90
No
W.19.2X6.16
17
Wall
605
0.065
17.8
270
90
Yes
W.19.2X6.16
21
Roof
3077
0.031
30
0
19
Yes
R.30.2X4.24
Attic
24
Door
28
0.330
0
0
90
Yes
None
Solid Wood
SLEEPING
- Existing
3
Wall
27
0.065
17.8
0
90
No
W.19.2X6.16
4
Wall
87
0.065
17.8
0
90
Yes
W.19.2X6.16
6
Wall
7
0.065
17.8
45
90
Yes
W.19.2X6.16
8
Wall
158
0.065
17.8
90
90
Yes
W.19.2X6.16
12
Wall
117
0.065
17.8
180
90
Yes
W.19.2X6.16
18
Wall
50
0.065
17.8
270
90
No
W.19.2X6.16
19
Wall
138
0.065
17.8
270
90
Yes
W.19.2X6.16
22
Roof
380
0.031
30
0
19
Yes
R.30.2X4.24
Attic
HOUSE -
Existing
5
Wall
146
0.065
17.8
0
90
Yes
W.19.2X6.16
9
Wall
48
0.065
17.8
90
90
No
W.19.2X6.16
10
Wall
88
0.065
17.8
90
90
Yes
W.19.2X6.16
13
Wall
119
0.065
17.8
180
90
Yes
W.19.2X6.16
15
Wall
56
0.065
17.8
225
90
Yes
W.19.2X6.16
20
Wall
100
0.065
17.8
270
90
Yes
W.19.2X6.16
23
Roof
348
0.031
30
0
19
Yes
R.30.2X4.24
Attic
COMPUTER METHOD SUMMARY Page 10 C -2R
Project Title.......... 81-645 Brown Deer P1. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM C -2R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
---------------------------------=---------------------------------------------
PERIMETER LOSSES
Length F2 Insul Solar
Surface (ft) Factor R-val Gains Location/Comments
------------ --------------------- ----- ----------------------
LIVING - Existing
25 SlabEdge 324 0.760 R-0 No To Outside
26 SlabEdge 38 0.510 R-0 No To Garage
SLEEPING - Existing
27 SlabEdge 66 0.760 R-0 No To Outside
28 SlabEdge 9 0.510 R-0 No To closet
HOUSE - Existing
29 SlabEdge 68 0.760 R-0 No To Outside
30 SlabEdge 5 0.510 R-0 No To closet
FENESTRATION SURFACES
---------------------
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
------------------ ----- ----- ----- --- ------------ ------------------------
LIVING - Existing
1 Wind Front (N) 5.0 0.490 0.560 0 90 Standard Vinyl/Wood Fixed
2 Wind Front (N) 9.0 0.490 0.560 0 90 Standard Vinyl/Wood Fixed
3 Door Front (N) 48.0 0.490 0.560 0 90 Standard Vinyl/Wood Patio Door
4 Door Front (N) 24.0 0.490 0.560 0 90 Standard Vinyl/Wood Patio Door
8 Wind Left (E) 8.0 0.490 0.560 90 90 Standard Vinyl/Wood Operable
9 Wind Left (E) 20.0 0.500 0.410 90 90 Standard Glassblock
10 Wind Left (E) 55.0 0.490 0.560 90 90 Standard Vinyl/Wood Operable
11 Wind Left (E) 48.0 0.490 0.560 90 90 Standard Vinyl/Wood Fixed
13 Wind Back (S) 24.0 0.490 0.560 180 90 Standard Vinyl/Wood Operable
15 Wind Back (S) 15.0 0.490 0.560 180 90 Standard Vinyl/Wood Fixed
16 Wind Back (S) 46.0 0.490 0.560 180 90 Standard Vinyl/Wood Fixed
17 Door Back (S) 128.0 0.490 0.560 180 90 Standard Vinyl/Wood Patio Door
18 Wind Back (SW) 36.0 0.490 0.560 225 90 Standard Vinyl/Wood Fixed
20 Wind Right (W) 18.0 0.490 0.560 270 90 Standard Vinyl/Wood Operable
21 Wind Right (W) 47.0 0.490 0.560 270 90 Standard Vinyl/Wood Fixed
22 Door Right (W) 48.0 0.490 0.560 270 90 Standard Vinyl/Wood Patio Door
23 Wind Right (W) 5.0 0.490 0.560 270 90 Standard Vinyl/Wood Fixed
24 Door Right (W) 24.0 0.490 0.560 270 90 Standard Vinyl/Wood Patio Door
SLEEPING - Existing
5 Wind Front (N) 8.0 0.490 0.560 0 90 Standard Vinyl/Wood Fixed
7 Door Front (NE) 20.0 0.490 0.560 45 90 Standard Vinyl/Wood Patio Door
14 Door Back (S) 48.0 0.490 0.560 180 90 Standard Vinyl/Wood Patio Door
25 Wind Right (W) 12.0 0.490 0.560 270 90 Standard Vinyl/Wood Fixed
HOUSE - Existing
6 Wind Front (N) 30.0 0.490 0.560 0 90 Standard Vinyl/Wood Fixed
12 Door Left (E) 40.0 0.490 0.560 '90 90 Standard Vinyl -/Wood Patio Door
19 Door Back (SW) 20.0 0.490 0.560 225 90 Standard Vinyl/Wood Patio Door
26 Door Right (W) 40.0 0.490 0.560 270 90 Standard Vinyl/Wood Patio Door
COMPUTER METHOD SUMMARY Page 11 C -2R
Project Title.......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM C -2R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
OVERHANGS AND SIDE FINS
---Window-- ------Overhang----- ---Left Fin--- ---Right Fin --
.Area Left Rght
Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght
----------- ----- ----- ----- ---- ---- ---- ---- ---- ---- ---- ---- ---- ----
LIVING - Existing
1 Window 5.0 3.5 3.0 11:0 0.5 11.0 0.1 11.0 30.0 8.0 n/a n/a n/a
2 Window 9.0 n/a 9.5 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
3 Door 48.0 n/a 9.5 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
4 Door 24.0 3.5 3.0 11.0 0.5 11.0 0.1 11.0 30.0 8.0 n/a n/a n/a
8 Window 8.0 2.5 3.0 4.0 0.5 4.0 4.0 3.5 4.0 10.0 3.5 4.0 10.0
16 Window 46.0 n/a 14.5 8.17 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
17 Door 128.0 n/a 14.5 8.17 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
20 Window 18.0 n/a 1.0 5.7 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
21 Window 47.0 n/a 1.0 5.7 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
22 Door 48.0 n/a 1.0 5.7 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
23 Window 5.0 n/a 9.5 25.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
24 Door 24.0 n/a 9.5 25.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
SLEEPING - Existing
5 Window 8.0 n/a 9.5 25.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
7 Door 20.0 n/a 6.67 1.9 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
14 Door 48.0 n/a 6.67 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
25 Window 12.0 n/a 2.0 1.0 0.5 n/a n/a n/a n/a. n/a n/a n/a n/a
HOUSE - Existing
6 Window 30.0 n/a 5.7 1.9 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
12 Door 40.0 n/a 6.67 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
19 Door 20.0 n/a 6.67 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
26 Door 40.0 n/a 6.67 1.0 0.5 n/a n/a n/a n/a n/a n/a n/a n/a
THERMAL MASS
------------
Area Thick Heat Conduct- Surface
Mass Type (sf) (in) Cap ivity UIMC R -value Location/Comments
--------------- ------ ----- ------------- ----------- ----------------------
LIVING - Existing
1 SlabOnGrade 2100 4.5 28.0 0.98 4.60 R-0.0 Exposed
2 SlabOnGrade 977 3.5 28.0 0.98 1.80 R-2.0 Covered
SLEEPING - Existing
3 SlabOnGrade 380 4.5 28.0 0.98 4.60 R-0.0 Covered
HOUSE - Existing
4 SlabOnGrade 348 4.5 28.0 0.98 4.60 R-0.0 Covered
COMPUTER METHOD SUMMARY Page 12 C -2R
Project Title........... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -FORM C -2R I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer P1. I
-------------------------------------------------------------------------------
HVAC SYSTEMS
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a High Mass Design.
This building incorporates non-standard Water Heating System
REMARKS
Refrigerant
Tested
ACCA
System
Minimum Charge and
Duct
Duct
Duct
Manual
Duct
Type
-------------
Efficiency
-----------
Airflow
----=---------------
Location
R -value
-------
Leakage
-----------------
D
Eff
----
LIVING
Furnace
0.780
AFUE
n/a
Attic
R-4.2
No
No
0.743
ACSplit
12.00
SEER
No
Attic
R-4.2
No
No
0.596
SLEEPING
Furnace
0.780
AFUE
n/a
Attic
R-4.2
No
No
0.743
ACSplit
11.00
SEER
No
Attic
R-4.2
No
No
0.596
HOUSE
Furnace
0.780
AFUE
n/a
Attic
R-4.2
No
No
0.743
ACSplit
11.00
SEER
No
Attic
R-4.2
No
No
0.596
WATER
HEATING SYSTEMS
---------------------
Number
Tank
External
in Energy
Size
Insulation
Tank Type
Heater
Type
Distribution Type
System Factor (gal)
R -value
------------
DHW
-----------
-------------------
--------------
------
----------
1 Storage
Gas
Standard
1
0.62 30
R-
n/a
DHW1
2 Storage
Gas
Standard
1
0.62' 70
R-
n/a
SPECIAL FEATURES AND MODELING ASSUMPTIONS
-----------------------------------------
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates a High Mass Design.
This building incorporates non-standard Water Heating System
REMARKS
HVAC SIZING Page 13 HVAC
Project Title:......... 81-645 Brown Deer Pl. Date..10/05/03 16:21:38
Project Address........ 81-645 Brown Deer P1. ******* ---------------------
La Quinta *v6.01* I I
Documentation Author... Dawne Carsen Hallock ******* I Building Permit # I
Energy Management Group, Inc. 1 1
69-115 Ramon Rd., #F1364 I Plan Check / Date I
Cathedral City, CA 92234 1 1
760-772-3642 1 Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -HVAC SIZING 1
1 User#-MP0999 User -Energy Management Group, ' Run -81-645 Brown Deer P1. 1
-------------------------------------------------------------------------------
GENERAL INFORMATION
-------------------
Floor Area.................
Volume .....................
Front Orientation..........
Sizing Location............
Latitude.... .............
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range ...............
Interior Shading Used......
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
3805 sf
40303 cf
Front Facing 0 deg (N)
LA QUINTA
33.8 degrees
32 F
70 F
112 F
78 F
34 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
--------------------------------
Heating Cooling
Description (Btuh) (Btuh)
-------------------------------------------------------
Opaque Conduction and Solar......
Glazing Conduction ...............
Glazing Solar ....................
Infiltration .....................
Internal Gain ....................
Ducts ............................
Sensible Load ....................
Latent Load ......................
Minimum Total Load
28058
14061
15388
13768
n/a
27312
21282
14084
.n/a
2465
6473
7169
71201
78859
n/a
15772
71201 94630
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
HVAC SIZING Page 15 HVAC
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Project Title.......... 81-645 Brown Deer P1. Date..10/05/03 16:21:38
MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -HVAC SIZING I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
---------------- --------------------------------------------------------------
ZONE 'HOUSE'
Floor Area ....................... 348 sf
Volume ........................... 3306 cf
Heating Cooling
Description (Btuh) (Btuh)
Opaque Conduction and Solar...... 3853 1729
Glazing Conduction ............... 2421 2166
Glazing Solar .................... n/a 5029
Infiltration ..................... 1746 1155
Internal Gain .................... n/a 189
Ducts ............................ 802 1027
Sensible Load .................... 8822 11295
Latent Load ...................... n/a 2259
----------- -----------
Minimum Zone Load 8822 13554
TABLE OF CONTENTS TOC
-------------------------------------------------------------------------------
Project Title.........: 81-645 Brown Deer P1. Date..10/05/03 16:21:38
Project Address........ 81-645 Brown Deer Pl. ******* ---------------------
La Quinta *v6.01* I I
Documentation Author... Dawne Carsen Hallock ******* I Building Permit # I
Energy Management Group, Inc. I I
69-115 Ramon Rd., #F1364 I Plan Check / Date I
Cathedral City, CA 92234 I I
760-772-3642 I Field Check/ Date I
Climate Zone........... 15 ---------------------
Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc.
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
I MICROPAS6 v6.01 File-03EATONA Wth-CTZ15S92 Program -TOC I
I User#-MP0999 User -Energy Management Group, Run -81-645 Brown Deer Pl. I
-------------------------------------------------------------------------------
TABLE OF CONTENTS
-----------------
Report Page
FORM CF -1R ................ 1
FORM MF -1R ................ 5
FORM C -2R ................. 8
HVAC SIZING ............... 13