0308-186 (BLCK)U)
1-
N U)
W
O M
d
0 Z r�
CC:) 0
� (O
J
ILLI LU
U)
Z
(y)
L0
N
ON
U °)
CL Q
Lo Qcc
0
0
J Q
mUU
O
� U-)
Z
obn
�a
J
LICENSED CONTRACTOR DECLARATION
"`I hereby affirm under penalty of perjury that I am licensed under provisions of
Chapter 9 (commencing with Section 7000) of Division 3 of the Business and
Professionals Code, and my License is in full force and effect.
License # Lic. Class Exp. Date
55.2140 C33 B RIC 06pol2c
/Date " ' �� fir Signature of Contractor
y� /r
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's
License Law for the following reason:
( ) I, as owner of the property, or my employees with wages as their sole
compensation, will do the work, and the structure is not intended or offered for
sale (Sec. 7044, Business & Professionals Code).
( ) I, as owner of the property, am exclusively contracting with licensed
contractors to construct the project (Sec. 7044, Business & Professionals
Code).
( ) I am exempt under Section B&P.C. for this reason
Date ', I �-�^ r} Signature of Owner A.,
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
( ) I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
(iA I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this
permit is issued. My workers' compensation insurance carrier & policy no. are:
Carrier STATE FUND Policy No. OOD9073-2002
(This section need not be completed if the permit valuation is for $100.00 or less).
( ) I certify that in the performance of the work for which this permit is issued,
I shall not employ any person in any manner so as to become subject to the
workers' compensation laws of California, and agree that if I should become
subject to the workers' compensation provisions of Section 3700 of the Labor
Code, I shall forthwith comply with those provisions.
Date: r, fl r' -:. " Applicant 6, s
Warning: Failure to secure WorkersjCompensation coverage is unlawful and
shall subject an employer to criminal penalties and civil fines up to $100,000, in
addition to the cost of compensation, damages as provided for in Section 3706
of the Labor Code, interest and attorney's fees.
IMPORTANT Application is hereby made to the Director of Building and Safety
for a permii subject to the conditions and restrictions set forth on his
application.
1. Each person upon whose behalf this application is made & each person at
whose request and for whose benefit work is performed under or pursuant to
any permit issued as a result of this applicaton agrees to, & shall, indemnify
& hold harmless the City of La Quinta, its officers, agents and employees.
2. Any permit issued as a result of this application becomes null and void if
work is not commenced within 180 days from date of issuance of such
permit, or cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is
correct. I agree to comply with all City, and State laws relating to the building
construction, and hereby authorize representatives of this City to enter upon
the above-mentioned property for inspection purposes.
Signature (Owner/Agent) 1 = "u'"'`-! �' ' �0' Date j J
= BUILDING PERMIT PERMIT#
`
DATE VALUATION LOT ` TRACT
tkM4= S3AID
JOB SITE
APN
ADDRESS 81_675
-6 8= rgt.TgU X+t�.NZ
,
OWNER
CONTRACTOR / DESIGNER / ENGINEER
ALFRED & BA MA A (#IEEE
CAL PA 'n, C POOLS
Sl -675 BRI IT7ZBU%. 17 M4E
419-301 BAlADGEP�1CRM. , 4200
LA Q UINTA CA, 92253
'PALM DEff RT CA 92211
(7450)32.2.7782 (Mio 6219
USE OF PERMIT
16 L.P. 5' HIGH BLOCK WALL, KJR ?IRXPL.ACE PIER. PLAN
5 FLT, WALL 16,00 LF
R4"ITKATIM COSI' Wr CONS"T.Ft1J'C'iiON
346AO
P)P-?JXF. rte. SUMMARY
PLAN CHECK FEE - 101-000439-318 $9.75
CONSTRUCTION ",Z 101-000-4118-000 $13.00
AUG 15 2003
CITY OF LA QUINTA
FINANCE DEPT.
MM-TOTAL CONRIXUu" 014 A140 Ts7L,AN CHECK
$2417 3
:1.£,39 PRE, fPATD FMW
$0104
'3.'0TAI. I?KRMT FERS Dili: NOW
$24,75
RECEIPT
D�'(t
( /
BY�
E LNp EQ /L
INS C R
INSPECTION RECORD
OPERATION
DATE
INSPECTOR
OPERATION
DATE
INSPECTOR
BUILDING APPROVALS
MECHANICAL APPROVALS
Set Backs
Underground Ducts
Forms & Footings
Ducts
Slab Grade
Return Air
Steel
Combustion Air
Roof Deck
Exhaust Fans
O.K. to Wrap
F.A.U.
Framing
Compressor
Insulation
Vents
Fireplace P.L.
Grills
Fireplace T.O.
Fans & Controls
Party Wall Insulation
Condensate Lines
Party Wall Firewall
Exterior Lath
Drywall - Int. Lath
Final
Final
BLOCKWALL APPROVALS
steel
POOLS - SPAS
Set Backs A
Electric Bond
Footings
Main Drain
Bond Beam
Approval to Cover
Equipment Location
Underground Electric
Underground Plbg. Test
Final
Gas Piping
PLUMBING APPROVALS
Gas Test
Electric Final
Waste Lines -
Heater Final
Water Piping
Plumbing Final
Plumbing Top Out
Equipment Enclosure
Shower Pans
O.K. for Finish Plaster
Sewer Lateral
Pool Cover
Sewer Connection.
Encapsulation
Gas Piping
Gas Test
Appliances
K
Final
Final -
Utility Notice (Gas)
ELECTRICAL_ APPROVALS
Temp. Power Pole
Underground Conduit
Rough Wiring
Low Voltage Wiring
Fixtures
Main Service
Sub. Panels
Exterior Receptacles
G.F.I.
Smoke Detectors
Temp. Use of Power
Final
Utility Notice (Perm)
COMMENTS:
SIDE ELEVATION
N.T.S.
�o
CITY OF LA QUINTA
BUILDING A SAFETY DEPT.
APPROVED
FOR CONSTRUCTION
i \�J
03 By
I j
O�OO
JE:
= C
�DO�O
i• ��CIC� i � I -
� d- I
3
CHIMNEY
_ O D
IULuu u
El; QUARTZITE VENEER
FIREBOX
u � ,
HEARTH ❑
1 „
CONC. SLAB ❑❑❑�❑ I EXISTING GRADE
--I ---- -� I=1 I ::-SIRIII--I I-- I I I—III_
-i 11--1 11=--I 11—.1 11=1 11=-1 11=1 I I ;III; _.II I 11=111-111=1 11==11 �
-:i 11=1 I I--1 I i --I I I-
-1 I I—I i I-1 I I—III-----.-+= 1=1 I i=1 i 1=I. LEd
i=1 11=1 11=1 11- -1111 v4 a 11=1_I Ed I 1=1'
-Ca
I I-111=1 .
I Q a' - �a • . I I
I I=I I'- -: a a as I I=1► !=111-!
-1 11-1 I I—i I F I I _I 11-1 11-I'
-1 I I—I I i—I 11 t •. , d. I I; I I
I El I I-
I , �
-111—Ili 11—I I i—III—I III—III—III—I i !—III—I 11—
MEI-I i I -
FIREPLACE SECTION
N.T.S.
FIREPLACE NOTES:
1. FOOTING TO BE 6" WIDER THAN
BASE OF FIREPLACE AND 2' DEEP, WITH
#4 @8" O.C. IN FOOTING AND #4® 8"
O.C. VERTICAL.
2. 8XBX16 ORCO BLOCK, TYP.
STRUCTURE FOR FIREPLACE WITH #4
16" O.C. HORIZONTAL.
3. INSIDE OF FIREBOX TO BE
FIREBRICK, TYP.