Loading...
13-0289 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00000289 Property Address: 79235 CAMINO ROSADA APN: 604-191-011-73 -24517 Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 35316 T,it!t 4v4Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: PRIMAVERA NICHOLAS H 79235 CAMINO ROSADA LA QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: RENOVA ENERGY CORP 75181 MEDITERRANEAN AVENUE PALM DESERT, CA 92211 (760)568-3413 Lic. No..:: 910836 . rV_1 -------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. LicensLe�Cllaass: BiC10 C46 Q License No.: 910836 ' X`� �� Date: • + Contractor: r �NO T-KAy OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code:. Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name:. Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/26/13 IL III r Aly) WORKER'S COMPEN ATIO OECRAOIV' ��fPJ I hereby affirm under penalty of perjury one of the following eclar do I have and will maintain a certificate of consent o self-insu� pro ded for by Section 3700 of the Labor Code, fort a performance) v��c i this permi is _ /n' issued. V� �sFT � ' have and will maintain workers' compensation insurance, as required by Section bor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 9024501-12 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, IAshall forthwith comply with those provisions. Date: 141_{' I Applicant: LWLLU WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. , APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. 1 certify that I have read this application and state that the above information is correct. 1 agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of thiscountyto enter upon the above-mentioned property for inspection purposes. 'Date: AY'All ISignature (Applicant or Agent): Application Number . . . . . 13-00000289 Permit . . . SOLAR PERMIT Additional desc . . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . . 35316 Expiration Date 10/23/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1..00 3.0000 ---------------------------------------------------------------------------- EA SOLAR EQUIP MISCELLANEOUS 3.00 Permit; ELEC-MISCELLANEOUS Additiona'1 desc . Permit Fee . . . . 30.00 Plan Check Fee 7.50 Issue Date . . Valuation . . . . 0 Expiration Date 10/23/13 • Qty Unit Charge Per Extension BASE FEE 15.00 2.00 7.5000 EA ELEC PWR APP >1 TO <=10 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 14.7kW SOLAR ARRAY - (45) 327W SUNPOWER PANELS W/(1) 6000W & (1) 700OW SUNPOWER INVERTER (765SF) 2010 CALIFORNIA ELECTRICAL CODE. April 26, 2013 3:31:17 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 Fee summary Charged Paid Credited ----------------------------------------------- Due ---------- Permit Fee Total 52.50 .00 .00 52.50 Plan Check Total 13.13 .00 .00 13.13 Other Fee Total 2.00 .00 .00 2.00 Grand Total 67.63 .00 .00 67.63 LQPEfN11T BIR # Qty. of La Quinta Building & Safety Division P.O. Box 1504,78-495 Caile Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit Application and Tracking Sheet Permit # %3• ProjectAddress:79235 Camino Rosada Owner's Name: Nicholas Primavera A- P. Number: Address:79235 Camino Rosada Legal Description: City, ST, zip: La Quilita, CA 92253 contractor: Renova Energy Corp. 93 Telephone u .;. . Address: 75181 Mediterranean Ave Project Description: Residential Roof Mounted sour P 14.72kW DC City, ST, zip: Palm Desert, CA 92211 4S -7 5� V%,,� Telephone: 760-568-3413 ". state Lic. # : 910836 Ciry Lies. #;104947 Arch, Engr., Designer. Address: City., ST, Zip: Telephone. r. State Lic. #: , • '; Construction type: Occupancy: Residential . Project type (circle one): New Add'a Alter Repair Demo - Sq. Ft.:1905 # Stories:1 #Unit;: Name of contact Person: Lea Waki - 760-568-3413 . Telephone # of Contact Person: lea@renovasolar.corn Estimated Value of Project: $35 316M APPLICANT: DO NOT WRITE BELOW THIS LINE p Submittal Req'd Recd TRACKING PERMrr FEES Pian sets Pian Check submitted3 15. Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact PersonP[an Check Balance. Title 24 Cates. Plans picked up Construction Flood plain plan Plans resubmitted.. Mechanical Giuding plan 2'` Review, ready for correctio a Electrical Subeontactor List Called Contact Person Plumbing Grant Deed Plans picked up H.O.A. Approval Plans resubmitted Grading IN ROUSE.- ''" Review; ready for correctionsftuc Developer Impact Fee Planning Approval. Called Contact Person AXP.P. Pub. Wks. Appr Date or perm It issue School Fees L I Total Permit Fees (A u %A UK -38O5 167K\0A[-Phase High72KV Low 120/240V EXISTING METER# AR1 B4-3812 PROPOSED BI-DIRECTIONAL METER UPGRADE EXISING 125A MAIN SERVICE TO 225A MAIN SERVICE 120/240 VOLT LOCATED ON WEST EXTERIOR WALL 1O0AMP ACDISCONNECT EATON#DG223UR8 – 120/240 VOLT NEXT NEXT TO PANEL 125AMP COMBINER SQUARE-D#HOMD1GL125RB 120/240 VOLT NEXT IN GARAGE Lu � SUNPOVVER000OWATT INVERTER SPR-600Om-240 120/240 VOLT – -- LOCATEO|NCARAGE SUNP0VVER7OUOWATT INVERTER 3PR'70OOm-240 120/240 VOLT LOCATED |NGARAGE STRING #1.SPR /oonm STRING #o.SPR ronom ��-STRING #a.SPR rnn0m == STRING w4.SPR aoonm STRING #a.SPR 6UOUm F� STRING #6.SPR 000Om DRIVEWAY SOLAR MODULES ��A��� ~ ` �- �wv BACK YARD Rw0iffill'Z�Q SOLAR SYSTEM SIZE: 14.715 kW [}C CEC AC S`/STEM SIZE: 12.989kVVAC 1.THIS mA1471nnvvSOLAR ELECTRIC SYSTEM USING (*5)SuwpDvvenSpn-3zrws-VvHT-o(nz7WATT) PHOTOVOLTAIC MODULES. 2.THIS SYSTEM |SGmo-|mrsnr|soVIA UL -LISTED POWER CONDITIONING INVERTERS: (1)SUwPOvvenspR-7nonm'z*oAND (1)5uwPOvvEnGPR-6000m'240 o.THIS SYSTEM HAS woUPS, m0BATTERIES. 4.THIS |s*ROOF MOUNTED SYSTEM, ADDING lO8LB/SQ FT. FOLLOWING THE ROOF SLOPE. ROOF |8SPANISH TILE xT1o~PITCH. o,THE SYSTEMS SQUARE FOOTAGE |881oFr. MODULES HAVE xw AZIMUTH OF18O~ O. MODULES ARE ODEGREES TILT ABOVE ROOF SLOPE. 7.BUILDING |S(1)STORIES. o.LAG SCREWS ARE om^X4^AT48rO.C. MAX, WITH z.o^INTO FRAMING. g. MODULES WILL BsSECURED TOROOFTOP USING Uw|R*CSTANDOFF ATTACHMENTS. 1o.ATTACHMENTS WILL Bco0ueLs'pLxSHso. 11.DESIGNED FOR BASIC WIND SPEED OF1ouMPH PER Uw|RxCCALCULATIONS. 1o.VISIBLE EXPOSED CONDUIT SHALL mEPAINTED TOMATCH. 13. MODULE DIMENSIONS ARE 41.z'xs1.*^ 14,SYSTEM INSTALLATION SHALL BEPER NEC n9OAND |BSUBJECT TO FIELD INSPECTION oYTHE CITY. 1n.PROPER CLEARANCES SHALL Bs|NACCORDANCE WITH ALL ADOPTED | CAL FIRE GUIDELINES. | ��(`�T|7� 1 '' = �0' SCALE: � � � I 4W 40 OF Cp, at ' � C� _ (� <— (] [L Z _ 0_ LO Z (� � z C%4� Drawn By: Date Drawn: 3/08/13 .ti WARNING: CTRIC SHOCK HAZARD. DO NOT TOUCI MINALS. TERMINALS ON BOTH THE LIN D LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 17.94 Amps OPERATING VOLTAGE: 357.07 Volts MAXIMUM VOLTAGE: 550.28 Volts SHORT-CIRCUIT CURRENT: 19.38 Amps NOTE: MOUNT ON DC DISCONNECT 1 OF 2 OF SPR -7000m INVERTER LTk IC SHOCK HAZARD. DO NOT TOU( \LS. TERMINALS ON BOTH THE LII AD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 54.17 Amps OPERATING AC VOLTAGE: 240 Volts NOTE: MOUNT ON AC COMBINER COVER 3" - THIS PANEL IS FED BY TWO SOURCES: SOLAR PHOTOVOLTAIC SYSTEM ON PREMISES NOTE: MOUNT ON SERVICE PANEL 3" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, THE NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. NOTE: MOUNT ON INVERTERS I ®WARNING: THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 225A MAIN PANEL 100 AMP AC DISCONNEC [115 AMP AC COMBINER SUNPOWER 6000W INVERTER SUNPOWER . U111111111111M. 7000W INVERTER NOTE: MOUNT ON SERVICE PANEL WARNING: !CTRIC SHOCK HAZARD. DO NOT TOUC MINALS. TERMINALS ON BOTH THE LIN D LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 17.94 Amps OPERATING VOLTAGE: 312.44 Volts MAXIMUM VOLTAGE: 481.5 Volts SHORT-CIRCUIT CURRENT: 19.38 Amps NOTE: MOUNT ON DC DISCONNECT 2 OF 2 OF SPR -6000m INVERTER 3" WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON AC COMBINER AND MAIN PANEL NEXT TO SOLAR BREAKERS 3" PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS AND AC COMBINER COVER 3/27/2013 3" PHOTOVOLTAIC DISCONNECT BREAKERS LOCATED INSIDE NOTE: MOUNT ON AC COMBINER COVER 3/27/2013 . 3" PHOTOVOLTAIC DISCONNECT BREAKER 1 OF 2 NOTE: MOUNT ON AC COMBINER NEXT TO 40A SOLAR BREAKER 3" PHOTOVOLTAIC DISCONNECT BREAKER 2 OF 2 NOTE: MOUNT ON AC COMBINER NEXT TO 35A SOLAR BREAKER 3" THE MAIN SERVICE BREAKER HAS BEEN DOWN -SIZED TO 175 AMPS. NO UP-SIZING IS PERMITED NOTE: MOUNT ON MAIN PANEL AT MAIN BREAKER NOTE: RED BACKGROUND WITH WHITE LETTERING 3/8" LETTER HEIGHT PROJECT SIGNAGE "AA 3 N/A MATERIALS (45) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES #SPR-327NE-WHT-D (1) SUNPOWER SPR -7000m - 7000W, 240 VOLT (1) SUNPOWER SPR -6000m - 6000W, 240 VOLT (1) SQUARE -DAC COMBINER, 125A, 2 -POLE #HOM816L125RB 3/27/2013 (1) EATON AC DISCONNECT, 100A NONFUSIBLE, 2?OLE #OG223UR13 (1) MONITOR/PV SUPERVISOR SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (45 x 327/1000) 14.715 kW CEC AC SYSTEM SIZE 12.989 kW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 N W _*_ E S NOTES+ SOLAR PRODUCTION STATS. 1 'NTA-L` Z P.V. PLAN J N/A c. 1 PANEL: AC COMBINER PANELVOLTAGE: 240/120 1P,3W CIRCUIT CODE: N: NON -CONTINUOUS 0 BUS: f®2 Lu L: LONG -CONTINUOUS M LOCATION: INSIDE GARAGE q 3/27/2013 N MOUNTING: SURFACE a O Q U R: DEMANDABLE RECEPTACLES AIC RATING: 10,000 K: KITCHEN 2 VA LOAD w TYPE I C.B. BUS C.B. TYPE w VA LOAD LOAD DESCRIPTION 0 OZ 0 LOAD DESCRIPTION A B U N R L TR P A B TR P L R N V A B v 1 3500 Sunpower SPR -7000m Inverter L 40 40 2 x L 2 3 3500 L - - x L Drawn By: 4 5 3000 Sunpower SPR -6000m Inverter L 35 35 2x L 6 7 3000 L x L 8 6500 6500 PHASE TOTALS PHASE TOTALS PHASE TOTALS A+B CONNECTED VA (CODE N): TOTAL PHASE A: 1 6500 CONNECTED VA (CODE L): 13000 TOTAL PHASE t3:1 6500 CONNECTED VA (CODE R): CONNECTED VA (CODE K): TOTAL CONNECTED KVA: 13.0 DEMAND KVA TOTAL ADJUSTED KVA: 13.0 TOTAL PANEL AMPS: 54.17 AMPS W/L CL: 54.17 NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. 6. ALL CONDUIT RUNS SHALL BE SUPPORTED IN ACCORDANCE WITH CODE. 0.5 TO 3.5 INCH STANDOFFS SHALL BE USED ON THE ROOFTOP SURFACE PER CEC Table 310.15(B) 7. ALL EXTERIOR CONDUIT AND BOXES SHALL BE RAIN -TIGHT AND SHALL USE OUTDOOR COMPRES; FITTINGS LISTED FOR USE IN WET LOCATIONS(OUTDOOR RAINTIGHT). CEC 314.15 SAFEGUARDS * SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE. * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED. * WILEY CABLE CLIPS SHALL BE USED. * EMT CONDUIT WHERE EXPOSED SHALL BE METAL CONDUIT. NO SET SCREWS SHALL BE ALLOWED. * ALL EMT SHALL USE OUTDOOR COMPRESSION FITTINGS. * SERIES SOLAR CIRCUITS SHALL BE FUSED AT 20 AMPS DC. * ALL EQUIPMENT SHALL BE LABELED. * ADD COMBINER / JUNCTION BOXES AS NEEDED. * AN INTERNAL BLOCKING DIODE IS PROVIDED IN EACH MODULE. *GROUND FAULT PROTECTION DEVICE IS INTERNALLY BUILT INTO SUNPOWER INVERTERS. *MODULE GROUNDING SHALL BE MADE WITH ILSCO GBL-4DB LUGS AND #8 SOLID BARE COPPER USING WEEB CONNECTIONS. *ALL NEUTRAL TO GROUND CONNECTIONS SHALL OCCUR IN THE MAIN PANEL. *EMT SHALL BE 1" MINIMUM. * JUNCTION BOX/ COMBINER BOX ENTRY SHALL USE COMPRESSION FITTINGS. CITY OF LA QUINTA BUILDING & SAFETY DEPT. t A P P 00VE FOR CONSTRUCTION 70 SUPPORT SYSTEM * WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH) * WIND EXPOSURE C * CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY * VISIBLE AND ACCESSIBLE * SOLARMOUNT-1 RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. .' Q5 NABCEP ACCREDITED PV Installation Company Renova Energy Corp. California - 2012 Ce tfr ..d E - my P- G P 5 Date Drawn: 3/08/13 Revision No. 1 Sheet No. E.1 0 Lu Q M q O N a O Q U Z fA 2 Q g�Z OZ M O 03 Z U C-4 A) 2 (L Drawn By: C. L. Date Drawn: 3/08/13 Revision No. 1 Sheet No. E.1 Fa• (2a) SOLARAR327RAY DC DISCONNECT 1 OF 2 Solar System Size: 14.715 kW DC c5 FUSED AT20AMPS PHOTOVOLTAIC MODULES CEC System Size: 12.989 y kWAC UPGRADE EXISTING 125A MAIN #SPR-327NE-WHT-D MODULE PTC RATING: 301AW 6) a THWN-2 1 #8 THWN-2 EGC (2) #8 THWN-2 SERVICE TO 225A MAIN SERVICE -� TO IID 240/120 VOLT, 2 POLE IEUK-3805 afu i M � o o_ Q (3 STRINGS OF 8 MODULES) "EMT SUNPOWER (1) #8 THWN-2 NEUTRAL LOCATED ON WEST EXTERIOR WALLF n c 04 SPR -7000m (1) #8 THWN-2 GEC 167 KVA C -Phase o ro CV 240V, 2P (1) E THWN-2 EGC 1" EMT (1 High 7.2 kV I 77 T N Q ti 0 - - Low 120/240 V m E V c') c n 00000000 Underground Transformer c J UPGRADE 1 5A MAIN BREAKER TO 175A MA N BREAKER U1 w N u) ^tn 0000n000 U m 1 C 00000000 METER # AR1 B4-3812 0 c E SOLAR BREAKERS SUITABLE FOR DISCONNECTING ! LOCATED IN GARAGE ` BREAKER PROPOSED PROPOSED BI-DIRECTIONAL MEANS PER NEC 690.14 AND 690.17 -, v1 METER # - � d o ' ALL WIRING BETWEEN MODULES SHALL BE TYPE USE -2(2) 04 THWN-2 IF EXPOSED (1) #4 THWN-2 NEUTRAL N BAR ALL CONDUIT SHALL BE 1" EMT OR LARGER. (1) #8 THWN-2 GEC ALL CONDUIT SHALL BE BONDED. (t2) #8 THWN-2 (1) #8 THWN-2 EGC 1 1/4" EMT G BAR ALL CONDUIT SHALL BE SUPPORTED BY RUBBER PYRAMID SUPPORTS 1 1/4" EMT /t8 THWN-2 EGC 1 1 STEEL CITY 12"X12"X4" OUTDOOR JUNCTION BOXES SHALL 403/27/2013 BE USED AS NEEDED. _ UrErt. ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF 35A GROUEr ND CONNECTORS TO PROTECT WIRES. 2^100 AMP NON -FUSIBLE (2) #4 THWN-2 TO PV Installation Company 12"x 12" x a" AC DISCONNECT 75 AMP 2 -POLE Renova Energy Corp. STEEL CITY OUTDOOR 3/27/2013 EATON #DG223URB SOLAR BREAKER California - 2012 JUNCTION BOX 0000000 CO AMP AC COMBINER 240V, 2P LOCATED NEXT TO MAIN PANEL SQUARE -0 # HOM816L125RB 0000000 P 0000000SPR-6000m ED IN SUNPOWER LOCATED IN GARAGE 240V, 2P (1)#4THWN-2 NEUTRAL NOM American Board of N'ABC EP (1) #8 THWN-2 GEC - I (6) #8 THWN-2 - 1 #8 THWN-2 EGC (1) #8 THWN-2 EGC0 1" EMT "GEC CONNECTED TO MAIN SOLAR ARRAY PANEL GRD 'EMT ENTRY TO MAIN PANEL (21) SUNPOWER 327 WATT MONITOR/ PV SUPERVISOR TO BE DETERMINED IN FIELD PHOTOVOLTAIC MODULES DC DISCONNECT 2 OF 2 LOCATED IN GARAGE INTERNET #SPR-327NE-WHT-D FUSED AT 20 AMPS (2) #8 THWN-2 t2o VOLT MODULE PTC RATING: 301 AW (1) #8 THWN-2 NEUTRAL (3 STRINGS OF 7 MODULES) (1) #8 THWN-2 GEC (1) #8 THWN-2 EGC 1" EMT *EGC = EQUIPMENT GROUNDING CONDUCTOR *GEC = GROUNDING ELECTRODE CONDUCTOR SINGLE LINE DIAGRAMSCALE: N/A Q Q DC CIRCUITS AC CIRCUITS W Q M MODULES TO SUNPOWER 7000W INVERTER SUNPOWER 7000W INVERTER TO AC COMBINER > 0 N Q N 3 STRINGS X 8 MODULES = 24 MODULES j� ` �29.17A CITY OF I /" O U I iN TA 7000W / 240 VOLT = X 1 = A (40 AMP SOLAR BREAKER) R NEC 21NTED C � MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low°C [via www.solarabcs.org]) x T coefV)) X # modules in series _ � CONDUIT SHALL I AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE IDE C_ MAX VOLTAGE DC= (64.9 +((25°C - 3°C) x.1766)) X 8 modules in series = 550.28 VOLTSBUILDING a TY DEPT. ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG O ` , 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.81 = 10.08 AMPS #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)) = 45.1 AMPS a Z �•/ FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER F * y' R 45.1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(B)(2)(a)] = 45.1 AMPS > 36.46 AMPS = OK DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. (3) #8 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND : ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG FOR CONSTRUCTION V EMT @ 40% FILL = (9) #8 THWN-2 WIRES = OK Z #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS O L 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK SUNPOWER 6000W INVERTER TO AC COMBINER E _ (� 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 1" EMT 40% FILL PER NEC TABLE CA = #8 THWN-2 WIRES = OK DATE q v __� 6000W / 240 VOLT = 25A X 1.25[PER NEC 215.2(A)11 = 31.25A (35 AMP SOLAR BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE m U CN Z @ (9) _ Z W MODULES TO SUNPOER 6000W INVERTER ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)] = 45.1 AMPS 2 3 STRINGS X 7 MODULES = 21 MODULES 45.1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(B)(2)(a)) = 45.1 AMPS > 31.25 = OK d MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low°C [via www.solarabcs.org)) x T coefV)) X # modules in series Drawn By: MAX VOLTAGE DC= (64.9 +((25°C - 3°C) x.1766)) X 7 modules in series = 481.5 VOLTS MAIN PANEL CONNECTION CALCULATION (3) #8 T AWG WIRE,% #8 THWN-2 GROUND 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.81 = 10.08 AMPS UPGRADE EXISTING 125 AMP MAIN SERVICE TO 225 AMP 1" EMT 40 @ 40 FILL = (9) #8 8 THWN-2 WIRES = OK MAIN SERVICE C. L. FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER UPGRADE EXISTING 125 AMP MAIN BREAKER TO 175 AMP MAIN BREAKER Date Drawn: DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. 120% OF 225 AMP BUSS: ALLOWABLE BACKFED AMPS [PER NEC 690.64(B)(2)] = 270 AMPS ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG 270 AMP - 175 AMP MAIN BREAKER = 95 TOTAL AMP ALLOWABLE AC COMBINER TO MAIN PANEL QttOFESS/pN 40A + 35A 3/08/13 #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS 75 AMP SOLAR BREAKER < 95 AMPS = OK = AMPS TOTAL (75 AMP SOLAR BREAKER) �Q a`EY L �f q� AC CONDUUIT SHALL BE MOUNTED INSIDE GARAGEFy Revision No. 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK ENGINEERED FOR 90°C TEMP. RATING OF CONDUCTOR & 44°C AMBIENT TEMP. PER SOLARABCS.ORG �' -P C' 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND #4 THWN-2 = 95 AMPS x .82[PER NEC TABLE 690.31(C)] = 77.9 AMPS rrn /27/2013 1" EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK 77.9 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(8)(2)(a)] = 77.9 AMPS > 75 = OK N 9 1 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.81 = 10.08 AMPS (3) #4 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND * E /13 #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS 1 1/4" EMT (4140% FILL = (7) #4 THWN-2 WIRES = OK 31.9 AMPS X .50[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)) = 15.95 AMPS > 10.08 AMPS = OK`STq �fCTR%rC-a�Q %CF CAUFC� Sheet No. 6 STRINGS= (12) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 1 1/4" EMT @ 40% FILL PER NEC TABLE CA = (16) #8 THWN-2 WIRES = OK �� L E.2 CALCULATIONS ALE: SC2 .2