Loading...
10-0689 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 10-00000689 Property Address: 78665 CABRILLO WY APN: 646-420-027- - Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 8000 Applicant: Architect or Engineer: BUILDING & SAFETY DEPARTMENT BUILDING PERMIT 1 f } -------------------------------------------- LICENSED CONTRACTOR'S DECLARATION - - ; - I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profession Is Code, and my License is in full force and effect. License Class: C46 License No.: 499505 Dater 7�Contrac11erjury OWNER-BUILDER DECLARATION I hereby affirm under penalty othat I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale ISec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). - (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractorls) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPER!\IIT Owner: MASTER ASSN FOR RANCHO 79325 RANCHO LA QUINTA LA QUINTA, CA 92253 --Contractor:-. ENERGY SERVICES 440 S. EL CIELO ROAD, I PALM SPRINGS, CA 92262 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/27/10 E}�Iid - d IF, JUL t2010 -- C1TY'0FLAQu1MTA-..--- .�. - --.... FWAN E 13EPT, I (760)778-1054 Lic. No.: 499505 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subje to the worker compensation provisions of Section �j 3700 of the Labor Code, I sh 11 fort comply with rose provisions. XDate: (���4pplicant: 01 WARNING: FAILURE TO SECURE W RKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO C NAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions. and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced withiA 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereb uthorize representatives of this county to enter upon the above-mentioned property fo nsp on purposes. � Date:/ —ate /. 4Signature (Applicant or Agent): LQPERMIT Application Number . . . . . 10-00000689 Permit ELEC-MISCELLANEOUS INV FEE Extension Additional desc . 30.00 'EC_ ,.'_:1:00 9.0000,EA SOLAR COLLECTOR Permit Fee . . . . 31.50 Plan Check Fee 3.94 Issue Date. . . . . SOLAR POOL WATER HEATING SYSTEM - 720SF Valuation . . . . 0 Expiration Date 1/23/11 TO EXISTING POOL PLUMBING. THIS PERMIT Qty. Unit Charge Per DOES NOT INCLUDE ADDITIONAL OR Extension BASE FEE 30.00 1.00 .1.5000 ----------------------------=----------------------------------------------- PER ELEC DEVICE/FIXTURE 1ST 20 1:50 Permit . SOLAR PERMIT INV FEE Plan Check Fee . . 4.88 Valuation . . . . 8000 ruui.iviiai uc;�. . . Permit Fee . . . . 39.00 Issue Date . . Expiration Date . . 1/23/11 - Qty Unit Charge- Per Extension BASE FEE. 30.00 'EC_ ,.'_:1:00 9.0000,EA SOLAR COLLECTOR < 1000 9.00 --'----------------------------------------------------------------------------- Special Notes and Comments SOLAR POOL WATER HEATING SYSTEM - 720SF COLLECTOR, ELECTRICAL CONTROL AND PIPING TO EXISTING POOL PLUMBING. THIS PERMIT DOES NOT INCLUDE ADDITIONAL OR ALTERATION TO EXISTING POOL PUMP. NOTE: SOLAR HEATING UNITS ARE GROUND MOUNTED ON ADJACENT (UN -ADDRESSED PARCEL) LOT J TRACT 28343 OWNED BY RANCHO LA QUINTA HOA. ***INVESTIGATION FEE ASSESSED PER 2007 CALIFORNIA BUILDING CODE APPENDIX CHAPTER 1 §108.4 FOR WORK COMMENCING BEFORE PERMIT ISSUANCE*** 2007 CALIFORNIA BUILDING CODES. July 27, 2010 3:32:29 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid ----------------------------------------------- Credited ---------- Due Permit Fee Total 70.50 .00 .00 70.50 Plan Check Total 8.82 .00 .00 8.82 Other Fee Total 1.00 .00 .00 1.00 Grand Total 80.32 .00 .00 80.32 L9er: lilap Help I Disclaimer I Sing Flaps Terms of Use I t.lierosoft Privacy GoreLogic' . "za 19 Copyr'rtt rcr�oG's Ap Fler„s P.aserrx. A4out0urroaic.uy t Contact Us i r"Aua : £d':eimp ! ienas �t Uec ' Poktias �ava-uH.....=: '....c...�._a 07/21/2010 19:40' 9092472798 PAGE 04 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION fF W, SUPPORT LEGS CAN ADJUST FOR ATTAC HME NT _ 4� EXAMPLE OF "GRAB NUTS" 012 GAUGE STEEL CHANNEL RECOMMENDED ATTACHMENT METHOD FOR PRO.RACK PRO RACK ASSEMBLY DETAIL PRD RACKTm FOR RIGID METAL PANELS 1 . 1 I HYSTALIATION CfREAR BRAGS REAR VIEW Of RACK INSTALLATION T D m CD cn SYSTEM DIAGRAM FOR OUTDOOR SWIMMING �7ff 0 4 N a H 3 W W 6L 6 2 Q W 1 0 0 EMENEFAAr12 CO .',■■■ 10 20 30 40 50 60 FLOW RATE - Gallons per minute 100 90 80 °-01 70 } Z60 W 50 V 40 IL W 30 W 20 10 0 SOLAR INDUSTRIES GUIDE SPECIFICATIONS Contractor to supply and Install collectors, nominal size (4' x 12', 4' x 10', 4" x 8") with overall frontal area of (47.3, 39.3, 31.4) square feet each. Collectors shall be fabricated from a propylene copolymer with stabilizer combination providing long term resistance to heat and light. The weight of collector when filled with water shall be no more than 1.3 pounds per square foot of frontal area. The collectors shall be capable of withstanding an internal static pressure of 85 psi at operating temperature and shall be resistant to corrosion, freezing, and internal scale accumulation. Collectors shall be capable of thermal performances of at least 85% efficiency when inlet fluid temperature equals ambient temperature and be capable of collecting solar energy when the Inlet fluid temperature exceeds the ambient temperature by 601F with 250 BTU per square foot per hour. Pressure head loss of a single panel must not exceed 0.30 feet water at recommended flow rate. Collector mounting center shall be 51 inches. Collector mounting shall consist of 18-8 chromium -nickel stainless steel mounting hardware with two continuous transverse straps having black polypropylene coafing. Transverse straps shall be fastened with 18.8 chromium -nickel stainless steel damps and brackets. Water connections shall be made with hose sections extruded from EPDM (ethylene-propylene-dene-terpolymer) 70 durometer minimum hardness. Hose damps shall be all stainless worth gear We with 18-8 chromium -nickel stainless band. The collectors shall meet or exceed the minimum standards established by the Florida Solar Energy Center, SRCC, and other applicable nationally recognized standards, and shall be manufactured In the U.SA. -.10 0 .10 .20 .30 .40 tf.i - to OF -HR -FT' 1 BTU THERMAL PERFORMANCE RATINGS Thermal Performance Equation - n = 85.8 - 3.42 Florida Solar Energy Center Certification Incident Angle Modifier - Kqr =1.0 - 0.03 (BTU's per standard day) (Rated in accordance with ASHRAE standard 96-80) 4 x 12 - 47,200 4 x 8 - 31,500 4 x 10 - 39,300 4 x 6- 23,600 ace', T ®Solar "p 1 Industries VS Solar Pool Heating Systems Part No. 19280-1 ®11/96 Solar Industries Solar Pool Heating Systems Available Through L4 GOLDLINI C0r1fM0L4z%' ,1r ,t The Recognized TechnologyLe Total solar system:control with' digital display of. pool .:...:' ' tpmperatu*re and.: solar system temperature: Plus,. full: system tliagnostic`LED's. The Aqua Sole ii. is. set by a single dial adjustment for desired pool temperature.: The''.,. Aqua Solar offers selectable high limit,•.programmable . recireulation'freeze: protection: -and noctumal:cooling to:'. customize any :installation. The Aqua Solar Time Clock Model has all .the features of the Aqua Solar with time Clock for control of the swimming,pools main filter pump. The time clock is programmable in 15 , :minute increments and can have multiple ON/OFF times. 'ExciusiW sola''r overriiie`featu�e alloviis for maximizing'sola gain while minimizing electricity cost. True automation and Convenience. America's best selling solar control is designed for easy and depend- able operation. The microprocessor based technology ensures reli-' ablity and accurate performance: The GL=235 offers advanced features to provide differential temperature control, selectable high limit, programmable recirculation freeze protection, nocturnal cooling. and optionaP booster: pump control: The GL -235 can handle -all systems; old or.new, pools & spas, 12 or 24VAC actuators. ,..,. M'(�7C `� . fm' �,fl�':�" �'� i [ ",'i y' � { Isi G. Y(:: H y' � i 'E' i.ic .. is l'�ii�CTS �:�� . [3v; red ., Gold�loklF �, F3;C.,E .�:_c .�3 f:�l° itP �f�t�'t� �Ji C.a ,�,' Actuator; diverfer 6alpe and'2 temperature :::.: .':; sensors are included in all Goidiine Solar'Comboi Goldline Controls is.the leading supplierofsolar:` controls nationwide. Goldline aiso.manufactures ihe.Aqua Rite Eleaionlc Chlorine:Generator:Tho Aqua. Rite makes' its dWn.chlorine from tableaaft" and keeps your pooYs:Water sparkling: Ask Your - pool professionbl a0outAmerica'6 best selling . . chlorine generator, the.Aqua Rfte: Bin # Qty of La Quinta "Building &r Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet , { Permit # ld • own Project Address: -71—�;,65- Owner's Name: },C,q tiC't0 v�G��ht } A. P. Number: Address: J�'WAo 4A-v ;1 Legal Description: City, ST, Zip: Contractor: / Tele hone: _ Address: f�%�� Project Description:"All ®� City, ST, Zip: ' �� 44 J r ` , :.;t..•{:: Vii, ff::.. ;•..:.:: :•2;.ti:.y::: :• Telephone: � 77 S :: •.;,<; : ::<>;:::.;.;•.:,;:, State Lic. # City Lic. #;01 Arch., Engr., Designer: i Address: City., ST, Zip: Telephone: State Lic. #: :.: • :sir'{:: v:i . Fi: ..\./.;}vr is �. }t. v. t}. "' """'' '' "'' ) v�V ��,r:{Yi:,v,}::vi:ti?i�:•%�::•iiii:i ':iii: <�:4i:. Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: 1 Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: X Q!Q APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit ^ Truss Caics. Called Contact Person Plan Check Balance ^ Title 24 Calcs. Plans picked up Construction70 'j,0— Flood plain plan Plans resubmitted Mechanical ^- Grading plan 2°" Review, ready for correctionsAssue Electrical Subcontactor List Called Contact Person Plumbing .� Grant Deed Plans picked up S.M.I. 1 H.O.A. Approval Plans resubmitted Grading IN HOUSE:- "d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees i Total Permit Fees WOLF COURSES, FF 61 8 s s FIE 61.0 7a FF 61-5 38 & USES: — —... —.P. FF 93.2 PE 62.7 45 !Fl? 03-1 IPE 62.6 44 PIE .51 7', ,fiE 02.0 42 FF V-3 PE 1 .8 /41 FF 62.0 PE 61.5 40 - A7 4 15 t�-- C�Z SEAL -4� 0 a tmz,-o —PEI DATE DATE Wt'- EMEEFd EWBAm L.E:GEND INV FIN15A ORA ME E" VAINow INDICATES J1 VERT EL(pVATroN FF PE TC. INDICATES FlklSll FLOOR ELEVATION INDICATES PAD ELEVATION INDICATES TOP OF CURB rn TP INDICATES TOP OF AC PAVEMENT 72 FS INDICATES FL GB INDICATES FLOWFINISLH INESURFACE INDICATES GRADE BREAK INDICATES CONCRETE INDICATES AC PAVEMENT INDICATES EXISTING INDICATES WATER MAIN & SERVICES INDICATES EXISTING SEWER MAIN & LAIERAL ES USE OF EXTENDED FOOTING PER SOIL ENGINEER-S RECOMM.(D:05') fAiDic4Tfs Pi(OVIDO 4 VOU4RE WALL OMAW4,5e 7pi-l— pimcATV5 POINT 015 &%mvR TJ-O�Tw"Nr. CLgWl`�O)J CLJR , i 31 INDICATES FLO.. GL5VATPON OF QkjT ER /7 (POOL LOT) 76 PE 62.5 \ '_ ' �� ,D, 77 FF 63.0 tpvIiI v PE 62.5 32 0 OD .I AF. cl o 0 Tftdli CT N0,1. 21305-� Z AR L—A 2U 0 N T A- UNAUT"ORIZED CHANGES I. USE& -THE ENGINEER PAEJ�PARIHG THESE PLANS WILL NOT BE RE�IBLE FOR OR LIABL FOR. MAPJTHOR-- ED OR USES Or THESE PANS. &L EHLNGES !0 THE PLANS MSTREWIIIT.W, AND MST HE APPW,vCjj ST THE P-PARER OF THESE PLANS cw`P.c,w N Tw X Tv==, 'Ll At TT�E tLza tm; 'LL L � r. IKLWIM :AFVr W ALL � 0 �&L w -w 1p �� MT " AN4P ml Tw �4 Pv!Tk)CTZIJN NTR4TM T 4ArU TO I�R, w; I—b ALL M� qM C�,W�m . I, *v1ss =1 , ", T rL:#.. IQL-v —t-FM rR!0, 'HE ��f �GLI�NtV � m5a SEAL b7p=nVETU" —E '043/5?( TRI STATE LAND SURVEYORS Pzll�l ��ll -�,& CIVIL ENGINEERS - '6035 CALLE ESTADO ItwE EA OU TNT A, CA 92253 i6ig PREPA04CD UNDER THE 1564-0271 FAX f6391564-0279 I L , I1. •-2C �C�JQZ-7D T A un:rcE.. ­E 3-3!-37 RITE JUNE i� OT, VN IN UNDERGROUND UTILITY ALFR-' ROUGH 4 -4 C29ADIIVG PLAN j'jTHE CITY OF LA OUTNTA, CALIFORNIA SHIFT 14- TRACT NO 28343 LOT 32 & 5 LOTS 39 THROUGH 44 OF 12SHF—, DEVELOPMENT PARCELS 4 & 6 F, LEIENC, IN THE NE 114 OF SECTION 31, T55. Fl_"E, SBM CR- I D DESERT nFvFtWWBNT I W.G : 95025