Loading...
10-0783 (RER)Prescriptive Certificate of Compliance: Residential CF -1R -ALT Residential Alterations Page 2 of 5) Project Name: Climate Zone N N of Stories I I — Mass and Furring Strips Construction (footnotes) 1. Indicate the type ofassembly to include; Hollow Unit Masonry Walls, Solid Unit Masonry, Solid Concrete Walls, Etc. A ddilional assemblies can befound Reference Joint Appendix JA4. 2. This is the U -Factor based on the thickness of the assembly in inches. 3. The R -value of the insulation to be added on the interior or exterior of the assembly. 4. The Calculated R- Value is the R -value of 1hefurred out section of the assembly. -6 The Final Assembly is calculated using Equation 4-2 or Equation 4-4of the Reference Joint Appendix JA4. The equation is the inverse of Column addedtoColumnl. Column K is the inverse from column J 7". Insert the calculated U-Jactor value on to the Opaque Surface Details in Column J F�NESTRATION PROPOSED AREAS 9 Replacing window alone - Replacement windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table.151-C. The Total Fenestration and West -facing Area requirements are not applicable. 0 Adding 50ft2 or less of window area - Newly installed windows shall meet the U -Factor and SHGC Value requirements of Component Package D in Table 151-C. 0 Adding more than 50ft2 of window area - Newly installed windows shall meet the U -Factor and SHGC Value and the Fenestration Area requirements of Component Package D in Table 151-C. Complete the Altered Fenestration AllowedArea Table on Page 2 of the CF -IR -ALT Orientation Fenestration Type and Frame (North, East, PropsedArea' Maximum Maximum NFRC or Default (Window, Glass Door or Skylight) South, West) (ft) U-factor�" SHGC" 1,4 Value 5 -3—eei-vo _fbLa- AU q a -s b e7to r 0,,3 "10' 0,,3/ 14(9 C44"16:!� e OrIle C � e C-( 2_ 7 1. Fenestration area is the area of total glazed product (i. e. glass plus frame). Exception: When a door is less than 50% glass, the fenestration a;�a may b�. the glbss area plus a "2 inch frame " around the glass. 2. Enter �alu� fro; C&Mponerit.Pockage D Requirements in Table 15 I -C. 3.-A clualfenestration products -installed Bnd as indicated in CF ­6R -EN V Form shall be equivalent to or have a lower U-Jactor andlor a lower SHGC value Ifiad that specified on th� CF- I R A L T Form. 4. Submit a completed WS -31? Formifa reduced SHGC is calculated with exterior shading. I 5.1f applicable at this stage enter "NFRC"for NFRC Certified windows or are CEC "Default" valuesfound in Table 116-A or B. I- ALTEkhD FENESTRATION ALLOWED AREAS (Complete if more than 50f 12 offenestration is added) A . B C D E F G Allowed Existing Fenestration Total Area 7CFA-oAfitife %of Fenestration Area Fenestration Allowed Proposed Are2 Dwelling CFA Area Removed Area Added (A x B) (E -D) + C Total Fenestration Area v?) .20 __T West Fenestration Area (Required In .05 CZ's 2, 4 & 7 -15) 1 1 1 1 1 1 1. West Fenestration Area includes west -sloping skylights and any skylights with a pitch less than 1: 12. 2. Westfacing glazing area removed cannot be "counted" twice. " In order to distribute the west glazing area removed to the other orientations, input the west glazing area removed in the Total Fenestration Area row, column D. 3. Include the Proposed Area of the West facingfenestration in both Area columns below. 4. To meet compliance, the Proposed Area must be less than or equal to the Total Allowed Areafor BOTH the Total and West Fenestration Ardas. Registration Number: Registration DatelTime: 2008 Residential Compliance Forms HERS Provider: August 2009