Loading...
07-1556 (AR)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 07-00001556 Property Address: 78170 CALLE CADIZ APN: 770-155-008-8 -000000- Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 11497 T4ht 4 4 Q" Applicant: Architect or Engineer: ----------------- LICENSED CONTRACTOR'S DECLARATION BUILDING & SAFETY DEPARTMENT BUILDING PERMIT I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B LicenseNo.: 670135 Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as'their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or. improve for the purpose of sale.). ( 1 I, as ownei of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. , B.&P.C. for this reason CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3697, Civ. C.). Lender's Name: Lender's Address: LQPERBIIT Owner: TADROS TADROS P O BOX 1024 PALM DESERT, A CA 92261 Contractor: NEW GENERATION BUILDERS P.O. BOX 1229 RANCHO MIRAGE, CA 92270 (760)969-2006 Lic. No.: 670135 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 10/22/07 ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor C/ode, II forth mply with a pr visions. Oat /0 A cant: /WARNING: FAILURE TO SECURE ORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, of cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned. property for inspection pur oses. 2fD7S, ature (Applicant or Agent): Application Number . . . . . 07-00001556 Permit . . . BUILDING PERMIT Additional desc . Permit Fee . . . . 135.00 Plan Check Fee 87.75 Issue Date Valuation . . . . 11497 Expiration Date 4/19/08 Qty Unit Charge Per Extension BASE FEE 45.00 10.00 ---------------------------------------------------------------------------- 9.0000 THOU BLDG 2,001-25,000 90.00 Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 22.04 Plan Check Fee 5.51 Issue Date . . . . Valuation 0 Expiration Date 4/19/08 Qty Unit Charge Per Extension BASE FEE 15.00 201.00 ---------------------------------------------------------------------------- .0350 ELEC NEW RES - 1 OR 2 FAMILY 7.04 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 30.50 Plan Check Fee 7.63 Issue Date Valuation . . . . 0 Expiration'Date 4/19/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH APPL REP/ALT/ADD• 9.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . . . . PLUMBING Additional desc . Permit Fee. 24.00 Plan Check Fee 6.00 Issue Date . . . . Valuation 0 Expiration Date 4/19/08 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 6.0000 EA PLB FIXTURE 6.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 ---------------------------------------------------------------------------- Special Notes and Comments 201 sq. ft. kitchen addition.August 28, LQPERAIIT Application Number . . . . . 07-00001556 ---------------------------------------------------------------------------- Special Notes and Comments 2007 12:23:05 PM jjohnson ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ENERGY REVIEW FEE 8.78 STRONG MOTION (SMI) - RES 1.14 Fee summary Charged Paid ---------- Credited ---------- Due ----------------- Permit Fee Total ---------- 211.54 ---------- :00 .00 211.54 Plan Check Total 106.89 .00 .00 106.89 Other Fee Total 9.92 .00 .00 9.92 Grand Total 328.35 .00 ..00 328.35 LQPERMIT CITY OF LA QUINTA SUB -CONTRACTOR. LIST JOB ADDRESS- PERMIT NUMBER OWNER BUILDER This form shall be posted on the job with the Building Inspection Card at all times in a conspicuous place. Only p6rsons.appearing on this list or their employees are, authorized to work on this job. Any changes to this list must be approved by the Building Division prior to commencement of work'. Failure to comply will result in a stoppage of work and/or the voidance.. of building permit. For each applicable trade, Information requested below must be completed by applicant. "On File" is not an acceptable response-. ... . .................................. .Class...VAR ... ......... ... ... .. ...... ................................ .... ......... ................ .......... .................... ....... . ....... - - t . .... . ..... OMP .... ....... .9MAQ0 VC .. - .. ......... ............. ............... .......... .. ...... ... .. ......... .................... ... .. . ......................... I ...... . .. .... .... .............. .......... .... ...... Company Name Classification License Number Exp; Date Carrier Name Policy Number Exp. Date License Number Exp. Date . ......... ... .. ... ... .......... .. (e.g. A, B, C-8) (xxxxxx) (xx/ xx x /,X Ie.g. State FuV, Calcomp) (Format Varies). (xx/xi/xx) (xxxx) (xx/xx/xx) EA -Y..V. .......... ... .......... . ............ .......... 6701 Nsw .............. ................ G s.J K 16 �Jrl t S.... v,_ T S. -Mr- -fd�.Vt .. ......... MASM . ... ..... . .......... ......... .. .. . ... . . . . . . . ....... . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T.. ................ H Himm ... .............. ............... ........... .:.H, V-A ............ .. . ................... . . ... . ........... ...... ............. .. ..... ............ .... . ..... 170J6, ........................................................... ............... ............... ............... H . .. ................. 7 3 �K_373,7 Q1Q Q5460z43C7 Zai ................. ................... ........... ............................... ............. ................ INS ......... .............. ...................... .......... .......... ........... .......... ............ Q ......... A. NTIN*Q-­�....... X.: ............................ %:::: ....... .. ........................................... ................ ............... . ... .............. ... ... .......... .4. f ......... ........ ...... .... ................ .. ......... .......... & AA&oAJ Z 15 7 7- IAA V&4P-X,,r 1r- Z_N \4 9 1 . ... .......... ...... ............ ........... ............................... P.P-* ................ �t r • a Bin # City of. La Quinta Building ST Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # (� \� Project Address: g- �� LLL C D a Owner's Name:7 wras d arhe Q c1ro s A. P. Number: S S — G _ Address: 7S - 1 70 Legal Description: City, ST, Zip:(,t ',.Aa l." 64 L Contractor: Telephone: Address: Project Description: City, ST, Zip: py� Telephone: o State Lie. # : City Lie. #: Arch., Eng., Designe Address: City, ST, Zip: Telephone: State Lie. #: Name of Contact Person: Z� 1� j^Q Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Sq. Ft.: # Stories: E#Units: Telephone # of Contact Person: 7(� Seo — . 3 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rec'd TRACKING . PERMIT FEES Plan Sets a Plan Check submitted'f Item Amount Structural Coles. 49 Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person D Plan Check Balance Energy Calcs. 44 Plans picked up oh X Construction Flood plain plan Plans resubmitted 1 61 Mechanical Grading.plan 2"d Review, rea for correctio sue Electrical Subcontactor List Called Contact son H Grant Deed Plans picked up I. Z,to H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '~ Review, ready for correctio srssue Developer Impact Fee Planning Approval Called Contact Person A.I Pub. Wks. Appr Date of permit issue _0 School Fees Q v' i Total Permit Fees --1 VCA LUtCAe i� sin r�c(.a.��•+� to - & - 07 7/�;2 5 lo -7 pPrdv�� CERTIFICATE OF COMPLIANCE Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES O rn RANCHO MIRAGE Date 8/29/07 La Quinta, CA 92253 INDIAN WELLS PALM LA QUINTA y No. 29664 (760) 771-8515 �INDIO Q 0 Owner Tadros APN # 770-1155-008 Address 78170 Calle Cadiz Jurisdiction La Quinta City La Quinta Zip 92253 Permit # Tract # Study Area Type Residential Addition No. of Units 1 Lot # No. Street Unit 1 8 78170 Calle Cadiz Unit 2 Unit 3 Unit 4 Unit 5 Comments S.F. 201 Unit 6 Unit 7 Unit 8 Unit 9 Unit 10 Lot # No. Street S.F. At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patiost walkways, residential additions under 5 00 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile ho mes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to Education Code Section 17620 and Government Code 65995 Et Seq. in the amount of $0.00 X 201 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Exempt - Elaine Tadros Check No. Name on the check Telephone Funding Exempt By Dr. Doris Wilson Superintendent Fee collected /exempted by Shar - McG1ly ey Payment Recd ir Over/Und&- c Signature C 'V NOTICE: Pursuant to Government Code Section 66020(d)(1), this will to notify you that the 90 -day approval period in which you may protest the fees o r other payment identified above will begin to run from the date on whi a building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to celled them on the Districtfs) behalf, whichever is earlier. NOTICE: This Document NOT VALID if Duplicated Embossed Original -Building Department/Applicant Copy - Applicant/Receipt Copy - Accounting TITLE 24 REPORT Title 24 Report for: Mr. & Mrs Tadros-Addition 78-170 Calle Cadiz La Quinta, CA 92253 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONST UCTION DA L 2� 7 B Project Designer: Brian De Coster, Design & Drafting Service P.O. Box 1054 La Quinta, CA 92253 (760) 771-6569 1 Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 Job Number: Date: AUG 2 2 2007 8/20/2007 EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is orized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. 1' EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 7 Form WS -5R Residential Kitchen Lighting 9 HVAC System Heating and Cooling Loads Summary 10 Room Load Summary 11 Room Heating Peak Loads 12 Room Cooling Peak Loads 14 EnergyPro 4.3 by EnergySoft Job Number: User Number: 6712 Certificate Of Compliance : Residential (Part 1 of 4) CF -1 R . Mr P. Mr-, Tadrns-Addffiteon oject Title (S) 180 deg Raised Floor Area: 8/20/2007 Date Project Address Fuel Type: Natural Gas Building Permit # Scott DPsinn & Title 24(760) Fenestration: 200-4780 Documentation Author 9.1 ft Telephone Plan Check/Date n _rgyPro Number of Dwelling Units: 1.00 15 Field Check/Date Complila�n'ce Method Avg. SHGC: 0.72 Number of Stories: Climate Zone TDV - Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 4.34 3.28 1.06 Space Cooling 96.45 90.29 6.16 Fans 13.22 12.36 0.86 Domestic Hot Water 9.36 8.80 0.57 Pumps 0.00 0.00 0.00 Totals 123.37 114.73 8.64 Percent better than Standard: 7.0% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Building Type: Y Single Family ❑ Addition Total Conditioned Floor Area: 2,697 ft2 ❑ Multi Family [� Existing + Add/Alt Existing Floor Area: 2,496 ft2 Building Front Orientation: (S) 180 deg Raised Floor Area: 0 ft2 Fuel Type: Natural Gas Slab on Grade Area: 2,695 ft2 Fenestration: Average Ceiling Height: 9.1 ft Area: 308 ft2 Avg. U: 1.13 Number of Dwelling Units: 1.00 Ratio: 11.4% Avg. SHGC: 0.72 Number of Stories: 1 *ILDING ZONE INFORMATION tne # of Thermostat Vent Name Floor Area Volume 7 697697 9447 Units Zone Type Type app_ Conditioned Setbark Hgt. 2 Area n/ F)dstingFAU & A/(,' OPAQUE OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rmf Wnnd 2 496 0 049 R-19 R-0 0 _0 20 Wall Wood 56 0.110 R-11 R-0 0 0 9.0 Wall Wood 324 0.110 R_11 R-0.0 n gn Wall Wnnd 438 n 11n R_11 R-0 0 At1-90 Wall Wood 465 0.110 R_11 R-0 0 180 9Q Door None 20 0 500 None R-0 0 180 90 Wall Wnnd 120 n110 _R11 R_0 0 An An Wall Wnnd 286 _0 1 in R_11 R_0 0 27n An Door None 20 0 500 None R-0.0 270 gQ Roof Wnnd 201 0 n3f; R-30 R-0.0 n gn Wall Wnnd 52 n n6g R_21 R-0 0 n An Wall Wnnd 10R n n69 R_91 R-0 0 270 _90 Gains Condition Y / N Status JA IV Reference Location / Comments ® ❑Fxisting 01-A4 Existing Res ® ❑Removed 09-A2 Existing Res ® ❑Fxicting 09-A2 Existing Res ® ❑Fxicting 09-A2 Existing Res ® ❑Fxicting 09-A2 Existing Res ® ❑Existing 28-A4 Existing Res IN ❑Removed 09-A2 Fxicting Res ® ❑Fxicting 09-A2 Fxicting Res ® ❑Fxicting 28-A4 Existing Res ® ❑New 02-A9 Addition ® ❑New 09-A6 Additinn ® ❑New 09-A6 Additinn ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ F-1 F-1 F-1 F-1 ❑❑ f-1 F-1 F-1 F-1 ❑❑ F-1 F-1 ❑❑❑ EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paoe:3 of 15 Certificate Of Compliance : Residential (Part 2 of 4) CF -1 R r. & Mrs Tadros-Addition Title 8/20/2007 Date FENESTRATION SURFACES True Cond. Location/ # Type Area LI -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments 1 Windnw Rear (N) 40.0 128 116-A 0.80 2 Window Rear (N) 24.0 1.280 116-A 0_80 3 Window Rear (N) 40.0 1.280 116-A 0_80 4 Window Rear (N) 24.0 1.280 116-A 0.80 5 Window Rear (N) 40.0 1.280 116-A 0_80 6 Window Rear (N) 12.0 1.280 116-A 0_80 L Window Right (E) 12.0 1.28 116-A 0_80 8 Window Front (S) 24.0 1.280 116-A 0.80 5 Window Front (S) 24.0 1_280.116-A 0.80 1Q Window Front (,S) 32.0 1_280 116-A 0_80 " Window Front (S) 20.0 1.280 116-A 0_80 12 Window Rear (N) 20.0 0.390 NFRC 0_37 _1a Window Rear (N) 8.0 0.770 NFRC -QAQ 14 Window Rear (N) 8.0 0.390 NFRC 0.37 15 Window Rear (N) 8.0 0.390 NFRC 0.37 16 Window Left (W) 12.0 0.390 NFRC 0_37 116-B _0 -9.0- RemnvedSingip Metal Clear Existina Res 116-B 0 90 Existing Single Metal Clear Existing Res 116-B 0 90 Existing Single Metal Clear Existing Res 116-B 0 90 Existing Single Metal Clear Existing Res 116-B 0 90 Existing Single Metal Clear Existing Res 116-B 0 90 Existing Single Metal Clear Existing Res 116-B 90 90 Existing Single Metal Clear Existing Res 116-B 180 90 New Single Metal Clear Existing Res 116-B 180 90 New Single Metal Clear Existing Res 116-B 180 90 New Single Metal Clear Existing Res 116-B 180 90 New Single Metal Clear Existing Res NFRC 0 90 New Milgard Classic Low -E Vinyl Addition NFRC 0 -9.Q New Milgard D INH Cir Low -E Addition NFRC 0 90 New Milgard Classic Low -E Vinyl Addition NFRC 0 90 New Milgard Classic Low -E Vinyl Addition NFRC 270 90 New Milgard Classic Low -E Vinyl Addition 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LEA REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Buq Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 230 None No Insulation 26-A1 Existing Existing Res Slab Perimeter 7 None No Insulation 26-A1 Existing Addition ab Perimeter 28 None No Insulation 26-A1 New Addition Run Initiation Time: 08/20/07 14:58:37 Run Code: 1187647117 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:4 of 15 Certificate Of Compliance: Residential (Part 3 of 4) CF -1 R r. & Mrs Tadros-Addition Title AC SYSTEMS 8/20/2007 Date Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type Existing FAU & A/C Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Existing Setback HVAC DISTRIBUTION Duct Duct Condition Ducts Location Heating Cooling Location R -Value Status Tested? Existing FAU & A/C Ducted Ducted Attic 4.2 Existing Yes Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A O SMITH FPSH-50-250 Small Gas Kitchen Pipe Ins 1 46,000 50 Altered 0.62 n/a n/a n/a n/a Existing DWH Small Gas pry -altered for Above_ 40,000 50 0.58 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Length (ft) Add 1/2" Control # HP Type In Plenum Outside Buried Insulation REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Brian De Coster, Design & Drafting Service Address: P.O. Box 1054 La Quinta, CA 92253 Telephone: (760) 771-6569 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: ignature) (date) Documentation Author Name: Tim Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michiqan Dr. Palm utsert, CA 02211 Telepho e 0-4 0 (signature) (d te) STAMP EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Pa°e:5 of 15 1 Certificate Of Compliance : Residential (Part 4 of 4) CF -1 R Title 8/20/2007 Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan I Field HERS Required Verification Items in this section require field testing and/or verification by a certified home energy rater under the supervision of a CEC- approved HERS provider using CEC approved testing and/or verification methods and must be reported on the CF -4R Plan Field installation certificate. he HVAC System "Existing FAU & A/C" incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on e CF -4R. 1 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:6 of 15 1 Mandatory Measures Summary: Residential (Page 1 of 2). MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. �J DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures 9 150(a): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. § 150(b): Loose fill insulation manufacturer's labeled R -Value: •§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls). �§ 150(d): Minimum R-13 raised Floor insulation in framed Floors or equivalent U -factor. § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs ❑ a ❑ ❑ ❑ ❑ ❑ a ❑ ❑ a ❑ 1. Masonry and factory -built fireplaces have: ❑ ❑ ❑ a. closable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ b. outside air intake with damper and control, Flue damper and control ❑ ❑ ❑ 2. No continuous burning gas pilot lights allowed. ❑ ❑ ❑ § 150(0: Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ CF -6R Form: § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ a ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. ❑ a ❑ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ a ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. § 150(i): Setback thermostat on all applicable heating and/or cooling systems. § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 150B. 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ lEnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:7 of 15 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (•) below. When this checklist is incorporated • into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. N/A DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than ❑ ❑ ❑ sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. ❑ ❑ ❑ 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ © ❑ duct tapes unless such tape is used in combination with mastic and draw bands. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ © ❑ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating ❑ © ❑ dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment ❑ © ❑ maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. ❑ § 114: Pool and Spa Heating Systems and Equipment 1�7��1 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the ❑ ❑ ❑ heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. ❑ ❑ ❑ b. Cover for outdoor pools or outdoor spas. ❑ ❑ ❑ 3. Pool system has directional inlets and a circulation pump time switch. ❑ ❑ ❑ § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously ❑ ❑ ❑ burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria ❑ ❑ ❑ Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table ❑ ® ❑ 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, ❑ ❑ ❑ luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined ❑ X❑ ❑ in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. ❑ ❑ ❑ OR are controlled by an occupant sensor(s) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kichens, bathrooms, garages, laundry rooms, and utility rooms be high luminaires less than 70 ft) OR by dimmer OR ❑ ❑ ❑ shall efficacy (except closets are controlled a switch are controlled by an occupant sensor that complies with Section 1`19(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are ❑ ❑ ❑ certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the ❑ ❑ ❑ same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. ❑ ❑ ❑ Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more ❑ ❑ ❑ dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page:8 of 15 Residential Kitchen Lighting Worksheet WS -5R r. & Mrs Tadros-Addition Title 8/20/2007 Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy High Efficacy? Watts Quantity Watts Other Watts (1) 14w Linear Fluorescent T5 Elec Yes No X 18.0 x 21 = or 378 (1) 26w Compact Fluorescent Triple 4 Pin Yes No X 28.0 x 8 = or 224 c Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes" No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or YesNo x = or Yes No x = or • Total A: 0 B: 602 COMPLIES IF A z B YES ❑ NO EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Paae:9 of 15 1 MVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Mr. & Mrs Tadros-Addition 8/20/2007 STEM NAME FLOOR AREA Existing FAU & A/C 2,697 26.0 OF 66.9 OF Outside Air 0 cfm Supply Fan 1680 cfm 66.9 OF SYSTEM LOAD Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM I Sensible 4,077 40,577 4,290 1220 47,380 0 6,406 5,478 0 0 0 0 0 0 0 0 0 6,406 5,478 53,3891 4,290 58 337 Existing HVAC System 29,530 15,795 89,000 Total Adjusted System Output 29,530 15,795 89,000 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am RICS (Airstream Temperatures at Time of H 66.9 OF 116.70F Heating Coil h Return Air Ducts `S Supply Air Ducts 113.7 OF ROOMS 70.0 OF DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0/77.6°F 81.6/69.9°F 81.6/70.0°F 65.1/64.1°F O Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 68.6 / 65.3 OF 1680 cfm 63.6% R.H. ROOMS 81.6/69.9°F 78.0/68.9°F h Return Air Ducts '4 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 10 of 15 ROOM LOAD SUMMARY PROJECT NAME DATE Mr. & Mrs Tadros-Addition 8/20/2007 STEM NAME FLOOR AREA Existing FAU & A/C 2,697 ROOM LOAD SUMMARY PAGE TOTAL TOTAL ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Existing Res Existing Res 1 3,544 35,267 3,290 3,544 35,267 3,290 940 43,672 Addition Addition 1 534 5,310 1,001 534 5,310 11001 80 3,708 PAGE TOTAL TOTAL 1 4,077 40,577 4,290 1,020 47,380 1 4,077 40,577 4,290 1,020 47,380 EnergyPro By EnergySoft User Number: User Job Number: Page: 11 of 15 ROOM HEATING PEAK LOADS Project Title Date Iq r. & Mrs Tadros-Addition 8/20/2007 oom Information Design Conditions Room Name Existing Res Time of Peak Jan 12 am Floor Area 2,496 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value QT OF Btu/hr I ISinale Metal Clear I 2,496.0 x 0.0490 x 44 = 5.381 324.0 X 0.1100 X 44 = 1,568 24.0 x 1.2800 X 44 = 1,352 40.0 X 1.2800 x 44 = 2,253 24.0 X 1.2800 X 44 = 1,352 40.0 X 1.2800 X 44 = 2,253 12.0 x 1.2800 X 44 = 676 438.0 X 0.1100 X 44 = 2,120 12.0 X 1,2800 X 44 = 676 465.0 X 0.1100 X 44 = 2.251 20.0 X 0.5000 X 44=440 24.0 X 1.2800 X 44 = 1,352 24.0 X 1.2800 X 44 = 1,352 32.0 X 1.2800 x 44= 1,802 20.0 x 1.2800 X 44=1 126 286.0 X 0.1100 X 44 = 1,384 20.0 X X 44=440 perimeter = 230.0 X 0.7300 X 44=7-388 X X X X X X = X X = X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X = X X = X X = nems snown wim an asierisK (-) aenore conaucuon rnrougn an interior surface to another room. Paye Total: 35 165 Infiltration: r 1.001X 1.064 X 2 496 X 9.00 X 0.485 / 6 ] X � = 8 507 `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 43,672 EnergyPro 4.3 by Energysoft User Number: 6712 Job Number: Page: 12 of 15 ROOM HEATING PEAK LOADS roject Title Date rIM=mation & Mrs Tadros-Addition 8/20/2007 Desi n Conditions Room Name Addition Time of Peak Jan 12 am Floor Area 201 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area LI -Value AT of Btu/hr IMilaard Dbl/Mtl Clr Low -E I 201.0 X X X X X X X X X X x X X X X x x x X X x x X x x X X X X X X x X X x X X X X 0.0360 X X x X X x x x X x x X X X X X X X X X X X X X X x X x X X X X x X X X X X X 44 = = = = = = = = = = = = = = = = = = = = 318 52.0 0.0690 44 158 20.0 0.3900 44 343 8.0 0.7700 44 271 8.0 0.3900 44 137 8.0 0.3900 44 137 108.0 0.0690 44 328 12.0 0.3900 44 206 Derimeter - 7.0 0,7300 44 225 perimeter = 28.0 0.7300 44 899 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 3,023 Infiltration: r 1.00 X 1.064 X 201 X 10.00 X 0.437 / 6] X 44 = 685 schedule Air Sensible Area Ceiling Height ACH DT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 3,708 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 13 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY Alllfir Title Date r. & Mrs Tadros-Addition 8/20/2007 oom Information Design Conditions Room Name: Existing Res Outdoor Dry Bulb Temperature: 11 1O Floor Area: 2,496 sf Outdoor Web Bulb Temperature: 780F Indoor Dry Bulb Temperature: 78'FOutdoor Daily Range: 340F r � U opaque surtaces Default Roof Prior 1978 to Present Default Wall 1978 to 1991 Default Wall 1978 to 1991 I Door Orientation N N E S S (W) Area Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Window Window Window Window Window Window Window Window Window U -Factor x 0.0490 X x 0.1100 X x 0.1100 X x 0.1100 X x 0.5000 X x 0.1100 x x 0.50001 X X 24.0 X X 0.0 X X 53.9 x X 53.9+ X x E X CLTD 1 Page Total Orientation Shaded Area X X x X x x x X x GLF + + + + + + + + + Unshaded Area x x X x X X X X x GLF N 0.0 53.9 24.0 53.9 N 0.0 53.9 40.0 53.9 N 0.0 53.9 24.0 53.9 N 0.0 53.9 40.0 53.9 N 0.0X 53.9+ 12.0X 53.9 E 0.0x 53.9+ 12.0X 99.6 S 0.0 53.9 24.0 54.1 S 0.0 53.9 24.0 54.1 S 0.0 53.9 32.0 54. S 0.0 53.9 20.0 54.1 Page Total Btu/hr 6,849 820 1,590 1,330 260 1,038 330 12 217 Btu/hr Internal Gain Btu/hr Occu ants 4 X Occupants X 230 Btuh/oCC. = 920 E ui ment 1 X Dwelling Units x 1 600 Watts/Sgft = 1 600 Infiltration: 1.064 x 1.15 X 158.15 X I 6 381 Air Sensible CFM ELA Z�T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 35,267 Latent Gain Btu/hr Occupants 0 X Occupants X 200 Btuh/oCC. = 800 Infiltration: 4 771 x 1.15 x 158.15 x 0.00287 = 2 490 Air Latent CFM ELA n W iTOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,290 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 14 of 15 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Title Date r. & Mrs Tadros-Addition 8/20/2007 oom Information Design Conditions Room Name: Addition Outdoor Dry Bulb Temperature: 111oF Floor Area: 201 sf Outdoor Web Bulb Temperature: 78oF Indoor Dry Bulb Temperature: 78OFOutdoor Daily Range: 340F Opaque Surfaces Orientation Area U -Factor CLTD 1 Btu/hr I U • R-21 Wall R-21 Wall N 201.0 X X X X X X X X X X X X 0.0360 X X X X X X X X X x x x 56.0 = = = = = = 405 N 52.0 0.0690 23.0 83 W 108.0 0.0690 33.0 246 0.0 30.0 8.0 30.0 240 N 0.0 21.6 8.0 21.6 173 N 0.0 21.6 8.0 21.6 173 W 0.0X 21.6+ 12.0X 43.6= 523 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration Window Nage I otal 1 7341 Orientation Shaded Area X X x x X X X X X GLF + + + + + + + + + Unshaded Area X X X x X x x X I x GLF = = = Btu/hr N 0.0x 21.6+ 20.0x 21.6= 433 N 0.0 30.0 8.0 30.0 240 N 0.0 21.6 8.0 21.6 173 N 0.0 21.6 8.0 21.6 173 W 0.0X 21.6+ 12.0X 43.6= 523 I Page Total 1543 Internal Gain Btu/hr Occu ants 4 X Occupants X 230 Btuh/occ. = 920 P p E ui ment 1 X Dwelling Units x 1 600 Watts/sgft = 1 600 Infiltration: 1.064 x 1.15 x 12.74 x 0 = 514 Air Sensible CFM ELA Z�,T TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5310 Latent Gain Btu/hr Occu ants 1 41 x Occupants X 1 200 Btuh/occ. = 800 Infiltration: 4 771 x 1.15 x 12.74 x 0.00287 = 201 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,001 EnergyPro 4.3 by EnergySoft User Number: 6712 Job Number: Page: 15 of 15