Loading...
BSOL2014-002878-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 4 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT Application Number-BSOL2014-0028 Property Address: 81872 CONTENTO APN: 767660018 Application Description: 12.2kW PV SYSTEM - (48) 255W PANELS/(1) INVERTER Property Zoning: Application Valuation: $27,050.00 Applicant: SOLARCITY CORPORATION 0 OUTSIDE CITY LIMITS LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License No.: :LIC -0108752 ., �iIi11�� �A�sAll r ��t:.LliiSz OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the- basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: VOICE (760) 777-7125 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/26/2014 Owner: GORDON RAYMOND 81872 CONTENTO LA QUINTA, CA 92253 Contractor: SOLARCITY CORPORATION 000TSIDE CITY LIMITS LA QUINTA, CA 92253 (650)638-1030 Llc. No.: :LIC -0108752 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and polity number are: Carrier: _ Policy Number: _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply lyith those provisions. Daca t4 Applican . WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT: Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above- mentioned roperty for inspection purposes. Date: Lf Signature (Applicant or Age FINANCIAL •• • DESCRIPTION ACCOUNT QTY, AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD r . RECEIPT # ". CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 101-0000-42403 0 $24.17 $0.00 PAID BY METHOD RECEIPT #' CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PV SYSTEM - ARRAY, FIRST 20 PC 101-0000-42600 0 $24.17 $0.00 PAID BY METHOD RECEIPT # - CHECK # CLTD BY Total Paid for ELECTRICAL: $48.34 $0.00 DESCRIPTION ACCOUNT QTY- AMOUNT PAID. PAID DATE PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 '- Permit Details PERMIT NUMBER City of La Quinta BSOL2014=00.28 -: - Description: 12.2kW PV SYSTEM - (48) 255W PANELS/(1) INVERTER ADDITIONAL Type: SOLAR Subtype: Status: APPROVED Applied: 10/13/2014 KHE Approved: 11/25/2014 AOR Parcel No: 767660018 Site Address: 81872 CONTENTO LA QUINTA,CA 92253 Subdivision: TR 31874-1 Block: Lot: 18 Issued: Lot Sq Ft: 0 Building Sq Ft: 0 Zoning: Finaled: Valuation: $27,050.00 Occupancy Type: Construction Type: Expired: No. Buildings: 0 No. Stories: 0 No. Unites: 0 Details: 12.2kW SOLAR ARRAY - (48) 255W KYOCERA PANELS W/ (1) FRONIUS IG PLUS -A-11.4 INVERTER [864SF] 2013 CALIFORNIA ELECTRICAL CODE. REGARDING SECOND REVIEW COMMENTS. E-MAIL 43 1 I Applied to Approved Printed: Wednesday, November 26, 2014 12:46:18 PM 1 of 3 RWYS 7EM5 ADDITIONAL CHRONOLOGY CHRONOLOGY TYPE STAFF NAME ACTION DATE COMPLETION DATE NOTES E-MAIL AJ ORTEGA 11/20/2014 11/20/2014 EMAIL SENT TO MELISSA AND BEAU AT SOLARCITY REGARDING SECOND REVIEW COMMENTS. E-MAIL AJ ORTEGA 11/25/2014 11/25/2014 EMAIL SENT TO MELISSA WITH SOLARCITY PLANS ARE APPROVED AND PERMIT IS READY TO ISSUE. PLAN CHECK SUBMITTAL KAY HENSEL 10/13/2014 10/13/2014 RECEIVED RESUBMITTAL MARY FASANO 11/25/2014 11/25/2014 RESUBMITTAL PHILIP JUAREZ 11/19/2014 PLAN CHECK RESUBMITTAL WITH CORRECTIONS THAT WERE E-MAILED TO APPLICANT. CONDITIONS Printed: Wednesday, November 26, 2014 12:46:18 PM 1 of 3 RWYS 7EM5 INSPECTIONS FINANCIAL CONTACTS SOLAR FINAL" NAME TYPE NAME ADDRESSI CITY STATE ZIP PHONE FAX EMAIL APPLICANT SOLARCITY CORPORATION 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 CONTRACTOR SOLARCITY CORPORATION 0 OUTSIDE CITY LIMITS LA QUINTA CA 92253 OWNER GORDON RAYMOND 81872 CONTENTO LA QUINTA CA 92253 INSPECTIONS FINANCIAL INFORMATION SOLAR FINAL" CLTD DESCRIPTION ACCOUNTQTY AMOUNT PAID . PAID DATE RECEIPT # CHECK # METHOD PAID BY BY BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 Total Paid forBUILDING STANDARDS ADMINISTRATION $2,00 $0.00 BSA: PV SYSTEM - ARRAY, 101-0000-42403 0 $24.17 $0.00 FIRST 20 PV SYSTEM - ARRAY, 101-0000-42600 0 $24.17 $0.00 FIRST 20 PC Total Paid for ELECTRICAL: $48.34 $0.00 PERMIT ISSUANCE 101-0000-42404 0 $91.85 $0.00 Total Paid forPERMIT ISSUANCE: $91.85 $0.00 TOTALS:00 INSPECTIONS SEQID INSPECTION TYPE INSPECTOR SCHEDULED COMPLETED DATE DATE RESULT REMARKS . NOTES SOLAR FINAL" Printed: Wednesday, November 26, 2014 12:46:18 PM 2 of 3 ' g? -W- SYSTEMS NON-STRUCTURAL TOM HARTUNG 10/13/2014 10/20/2014 10/16/2014 REVISIONS REQUIRED -Attachment Type`.. WAITING FOR REVISED PLANS PER SOLARCITY ERRORS IN CONDUCTOR SIZING. � : '-OWNER ' ' ' DESCRIPTION ' PATHNAME' ' 'SUBDIR ETRAKIT ENABLED. CONDUCTORS CHANGED DO NOT COMPLY WITH NON-STRUCTURAL AJ ORTEGA 11/19/2014 11/26/2014 11/20/2014 REVISIONS REQUIRED AJ ORTEGA DERATING REQUIREMENTS FOR CONDITIONS OF 2ND REVIEW REDLINED 0 REDLINED PLAN USE, ROOF TOP CONDUIT AND AMBIENT BSOL2014-0028 - SOLAR TEMPERATURE. NON-STRUCTURAL I AJ ORTEGA 11/25/2014 12/2/2014 1 11/25/2014 I APPROVED 0 Printed: Wednesday, November 26, 2014 12:46:18 PM 3 of 3 ��� SYSTEMS ATTACHMENTS -Attachment Type`.. CREATED a „ . - � : '-OWNER ' ' ' DESCRIPTION ' PATHNAME' ' 'SUBDIR ETRAKIT ENABLED. BSOL2014-0028 - SOLAR DOC 11/20/2014 AJ ORTEGA SOLAR 2ND REVIEW 2ND REVIEW REDLINED 0 REDLINED PLAN PLAN.pdf BSOL2014-0028 - SOLAR DOC 11/20/2014 AJ ORTEGA SOLAR 2ND REVIEW 2ND REVIEW 0 COMMENTS COMMENTS.pdf Printed: Wednesday, November 26, 2014 12:46:18 PM 3 of 3 ��� SYSTEMS bin # 0ty of LQ Quinta Req'd ' Building $r Safety Division Permit # P.O. Box 1504, 78-495 Calle Tampico . La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Project Address: q)37 2, (_O)jkrr- Owner's Name: u A. P. Number: Address: �2S Legal Description: City, ST, Zip: t_(L j vjCA 27 S 2, ' Contractor: C4 Telephone: '- I Address: Project Description: g City, ST, zip: 4 Telephone: Q,' UZg M-1, �) Si7i:yiif ii4 w 6i4ff:. :;,,�.> `/ 1 � O Plans resubmitted . State Lic. # : j City Lie. #; Arch., Engr., Designer: 2" Review, ready fo co re ctionjkstj A Address: City., ST, Zip: Telephone: ,.yl Construction Type: Occupancy: Plumbing , 'n }#1 `Yy f..:r}LJ.SN yf u+�,v`iY'rL:.Cj: State Lic. #: y;a^x;�f{k:�;� �r���;��z Project type (circle one): New AddAlter Repair Demo Name of Contact Person: He iss Ck Sq. FL: # Stories: # Units: Teltphonq #,of Contact Person: — M Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE I # Submittal Req'd We'd TRACKING PERMIT FEES Plan Sets J Plan Check submitted 1 3 Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss C21cs. Called Contact Person Plan Check Balance. Title 24 Calcs. Plans picked up Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2" Review, ready fo co re ctionjkstj A lectrical Subcontactor List Called Contact Pers tt Plumbing Grant Decd Plans picked up S.M.L H.O.A. Approval Plans resubmitted Grading IN I10USE:- 'rd Review, ready for correction ssu Developer Impact Fee Planning Approval Called Contact Person ,� �i A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Per mk;il V M I OCT 13.2014 MY OF LA QUrNTA COMMUNITY DEVELOPMENT Carmela Community Association C/o Desert Management P.O. Box 799, Rancho Mirage, CA 92270 766-862-1202 Fax 760-862-1210 October 2, 2014 Gordon & Margaret Raymond t- 81-872 Contento ' La Quinta, CA 92253 r� Re: 81-872 Contento --Solar Panel Applications Account No. 97-OW11 . Dear Mr. & Mrs. Raymond: The Design Review Committee has reviewed your Design Application for installation of Solar Panels. After review by the Archit4ural Comhiiiiikand Boacdfof Directors, your application has been approved as submitted.�'�� After work has been completed, please contact9me toisrycet. up a final inspection with the Committee.+<� r {t y If you require additional informl&i please feel free to contact me at 760-862-1202. Sincerely, BOARD OF DIRECTORS Carmela Comtmity Association Liz Schelbie Association Assistant Manager , B��7�. ���FFF '� •a �pj)t:10tt ctmdFE 42427 PJmd o Lane J=:a CA 91,'0 76C•8 amecompboar 2(o 8 pf � bruiRrd}t pt�/6ftotten�_ Hamt )mprit�tt�eft Fam 1Yosparpr�rrry np�n.Mt-,A 3fOQ d�+it �ke� to otea t7mn pnegi+P�+"� ^Q9�• �edynaia3.�in+ttaoudxrk�dfsa naxsr. trto�rbrte�td&a1,i �B: aad t �bib9tB) r" _ 3 Sda of Dmaiagc • t3hee�ld malnde �� of tf� derlRn; soba � tmme�, l.00adico ot'�tenrt bbfi�dadad oc: &shops.I�d*&mAaultLfu**tht:UNAMWR4;Ldit im rmwMdpWrto!VPzEr. • (Pbmre dteei item -FA __._ _ Btd>e-la Bubmw Nome � (bpe l laowm) _„� do P.gadpmmt _ —o C+w TFCDVW robowair. _.._ . Pei�l .---pmt -- W — ItaiR QAteea —side _ RM I /itdBtiaelB�oedm DOW.—S,01 e NOT yyRrrk Bwxw tEw lm T= Clot C IIsogo The Revkw Camtafo0oebo dmnrpined 4�at 81e ebota sQbm;iSf01 Ant" -W13 E'ApPrO Q�Cm�� Dimptiuve mftbtdbd 13 gnpleai- t 7 �teaeeraecse Bart�ilimd aao. C 3 adtl� e�teH pet4an of ptavi+lc akamb'uo mood. 0 Rm*u* paw cover Red () )lo act parr ooh vddino &M, { !. lbzlsd.p)+m>ms ORtirot WJSft W&W (No tcctetltmt 12 Who ofm)) to bsrRabeed� (} bvwli of moll}'ta icwwPinar %TM-MV04&m kSL (! AU RBfi soo be ktw wetmim. (() AD MW tccft MOOM told X*im anal o� to (f xxdbepWxftdlomrAcdWq atmmerfu* Uim. ( ) Ro*mfprv®tmnsd0ft .: itSR!. C _li�� ..?_ iri►. t tA� ('.;. lt. ;� ijlxvvl t 1^/Zh4bidat�wi% .... pap SolarCity. 11/08/2014 To: La Quinta The following required changes and revisions have been made for: Permit Review Date: 11/07/2014 Address: 81872 Contento St. Project: Raymond, Gordon Per plan check letter, REV A changes have been made as follows: 1) Conductor wires have been upsized to AWG #6. Upon review, it was determined that #8 was too small. 2) Conduit 1-1/4" EMT will be sufficient for new wire sizes . Please do not hesitate to get in touch with me if you have any questions or concerns. Thank you for your time and consideration on this project. Beau Millett SolarCity Inc. (650) 963-5100 x.2614 bmillett@solarcity.com RECEIVED 5 NOV 19 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT 3055 Clearview Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY v (650) 638-1029 SOLARCITY.COM AZ ROC 243771, CA CSLB 888104, CO EC 8041, OR CCB 180498, TX TDLR 27006 'SolarCity. 11/24/2014 To: La Quinta The following required changes and revisions have been made for: Permit Review Date: 11/21/2014 Address: 81872 Contento St. Project: Raymond, Gordon Per plan check letter, REV A changes have been made as follows: 1) Conductor wires have been resized to AWG #2. Upon review, it was determined that #6 was too small, based on the required DC . temperature derate of 0.41, the use of 4 strings with 12 modules per string, and the listed record low and average high temperatures of 13 and 107 OF, respectively. 2) DC Conduit has been resized to 1-1/2" EMT to be sufficient for new wire sizes. 3) Electrical calculations have been adjusted to match and reflect proper wire sizes. Please do not hesitate to get in touch with me if you have any questions or concerns. Thank you for your time and consideration on this project. Beau Millett SolarCity Inc. (650) 963-5100 x.2614 bmillett@solarcity.com 3055 Clearview Way San Mateo, CA 94402 T (650) 638-1028 (888) SOL -CITY F (650) 638-1029 SOLARCITY.COM A2 ROC 243771. CA CSLB 888104, CO EC 8041, OR CCB 180498. TX TDLR 27006 PROJECT: 81872 CONTENTO ST SPOKE WITH THE DESINER AT SOLAR CITY ABOUT THE WIRE SIZE ON THE SINGLE LINE (2/0) THEY SAID IT WAS A BAD DESIGN AND THEY WOULD RESUBMIT. Melissa Quintero From: AJ Ortega <Aortega@la-quinta.org> Sent: Thursday, November 20, 2014 9:38 AM To: ' Melissa Quintero; Beau Millett Subject: City of La Quinta - 81872 Contento 2nd Review Comments Attachments: BSOL2014-0028 - SOLAR 2ND REVIEW REDLINED PLAN.pdf Mr. Millett, The conductor size that was changed may exceed that allowed — Circuit conductors shall be sized to carry the larger of 125% of the maximum currents calculated in 690.8(A) without any additional correction factors for conditions of use or 100% of the maximum current after conditions of use have been applied. Please revise the conductor sizing schedule to justify the installation of the proposed conductor. See attached redlined plans for more information, or feel free to email me back with any questions or concerns. AJ Ortega, Building Inspector II City of La Quinta I Community Development Department Direct 760.777.7018 1 Fax 760.777.7011 aortega6a la-ouinta.om City of La Quinta 78-495 Calle Tampico) La Quinta, CA 192253 Phone 760.777.7000 www.la-auinta.org 1