05-3404 (SFD)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number:
05-00003404
Property Address:
81968 CONTENTO
APN:
767-200-011-9 -318741-
Application description: ?
DWELLING - SINGLE FAMILY
Property Zoning: ,
LOW DENSITY RESIDENTIAL
Application valuation:
175002
Ti&t 4 4 Q"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
DETACHED
Applicant: rchitect or Engineer:
------------ - ---------------- - --------------------
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License Class: B License No.: 352047
/ Da�� rector:
OWNE -BUILDER DECLARA ION
I hereby affirm under penalty of perjury that I am exempt from the Contracto s State License Law for the
following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and 10
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:lft
LQPERMIT
Owner:
TAYLOR WOODROW HOMES, INC.
15 CUSHING
IRVINE
IRVINE, CA 92618
Contractor:
TAYLOR WOODROW HOMES INC
15 CUSHING
IRVINE, CA 92618
(760)275-0598
Lic. No.: 352047
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 8/03/05
D Q D
AUG 0 8
CITY OF LA QUINTA
FINANCE - DEPT.
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
_Lf. -I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier LIBERTY MUTUAL Policy Number WA76SD283614055
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of t> Labor Code shall fo h ith comply with those ' ions.
ate: V Applicant —�
WARNING: FAILURE TO SECURE WO KERS' C ENSATION COVERAGE IS UNLAWF L, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HU RED THOUSAND
DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAG AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relatin ' ding construction, anji hereby authorize representatives
of this county to enter upon the above- ed prope for inspeyti o s.
SAP� nature (Applicant or Agent):
Application Number . . . . . 05-00003404
Permit
BUILDING PERMIT
Additional
desc . ..
Permit Fee
. . . .
905.50 Plan Check Fee
588.58
Issue Date
. . . .
Valuation . . . .
175002
Expiration
Date
1/30/06
Qty
Unit Charge
Per
Extension
BASE FEE
639.50
76.00
=---------------------------------------------------------------------------
3.5000
THOU BLDG 100,001-500,000
266.00
Permit
. . .
MECHANICAL
Additional
desc
Permit Fee
. . . .
83.50 Plan Check Fee
20.88
Issue Date
. .
.Valuation
0
Expiration
Date
1/30/06
Qty
Unit Charge
Per
Extension
BASE FEE
15.00
2.00
9.0000'EA
MECH FURNACE <=100K
18.00
2.00
9.0000
EA MECH B/C <=3HP/100K BTU
18.00
5.00
--------------------------------=-------------------------------------------
.6.5000
EA MECH VENT FAN
32.50
Permit
. . .
ELEC-NEW RESIDENTIAL
Additional
desc .
Permit Fee
. . . .
121.92 Plan Check Fee
30.48
Issue Date
. . . .
Valuation . . . .
0
Expiration
-Date
1/30/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2685.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
93.98
647.00
---------------------------------------=---------------=--------------------
.0200
ELEC GARAGE OR NON-RESIDENTIAL
12.94
Permit
. . .
PLUMBING
Additional
desc .
Permit Fee
. . . .
161.25 Plan Check Fee
40.31
Issue Date
. . . .
Valuation . . .
0
Expiration
Date
1/30/06
Qty Unit Charge
Per
Extension
BASE FEE
15'.00
15.00
6.0000
EA PLB FIXTURE
90.00
1.00
15.0000
EA PLB BUILDING SEWER
15.00
1.00
7.5000
EA PLB WATER HEATER/VENT
7.50
LQPERMIT
LQPERMIT
Application Number . . . . 05-00003404
Permit . . . PLUMBING
Qty Unit Charge Per
Extension
1.00 3.0000 EA PLB WATER.INST/ALT/REP
3.00
1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM
9.00
9.00 .7500 EA PLB GAS PIPE >=5
6.75
1.00 15.0000 EA PLB GAS METER
----------------------------------------------------------------------------
15.00
Permit . . . GRADING PERMIT
Additional desc .
Permit Fee 15.00 Plan Check Fee
..00
Issue Date . . . . Valuation . . .
. 0
Expiration Date 1/30/06
Qty Unit Charge Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
SFD - LOT 9, PLAN 1B 2685 SF.
2001 CODES. PERMIT DOES NOT INCLUDE
BLOCK WALLS, POOL, SPA OR DRIVEWAY
APPROACH.
----------------------=-----------------------------------------------------
Other Fees . . . . . . . . . DIF COMMUNITY CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
58.86
DIF FIRE PROTECTION -RES
97.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI),- RES
17.50
DIF STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged Paid Credited
--- - -------------
Due
---------- ---------- -------- 7- ----------
Permit Fee Total 1287.17 .00 .00
1287.17
Plan Check Total 680.25 .00 .00
,680..25
Other Fee Total 2481.36 .00 .00
2481.36
Grand Total 4448.78 .00, .00
4448.78
LQPERMIT
INSTaLATION UjRTWWATE. (Page 3
SIti M63 -5 -
DUCT LEAKAGE AND DESIGN DIAGNOSTICS
DUCT LBA"Gh,' 1t "OU(3-10M.
Pressurization Test Results (CFM @ 25 PA) Test Leakage (CFM)L_E_
Fan Flow
If Fan Flow is Calculated as 400 cfrrVton x number oftons, or as 21.7 x Meatinti! Capacity
In Thovsa.nds'of�atu/hr, enter Calcqj;!qd�valuo here
If f-aln flow .119 measured, enter measuredavalua-here
Leakage Fraction v Test Leakage/(M -,F4 ..#Io
Leakage/(Measured .glIq jkted n W)
Pass if leakage fraction -cA06 . PASS Fall
0 For AEROSOL TYPE SEALANTS ONLY -Th.efoI.l0wIqidl#gpq;1-lc tr.e;.Vqj.w"-completed:
Ductfan Prepsud ='on-atroush-inm fvo, .1 asu CFM,)
M 64kage
CHECK AFM FROM40 WALL:
O Yes 0 No 0 Pressure pan test or House pressurization test
C3 Yes 0 No 0 Visual. Inspection of Duct Connections
0 a
Pass POD
13 MBXOUA.'M,- EXPANSION MVR fM
[3 Yes E3 No - T-bermostatic Expansion Valve is installed and Access is - provided, for .inqnotion.
Yes is*pAss
Fall
ACCA
i. o Yes o No pomp -Du;t,,Oe n. -
_100A.. ftn,,I&o installation
matchesmian a.
2. 0 Yes a No 1XV is inst ' ailed orfan. flqw * been verified. Una 7XV, 0 0
verified fan Dow matches Acsi - - ftpm,CF4k Pass Fag
MmuredTan,flow -
Yes ,f6r:both -1 and2 is aPaps
0 1, the un0ersisned.-verify that -thei.k.bove diagnostic tat results -and the work 1-pedgm;dAssociated with:the test(s)>is:in confomuutce
with the ,requirements for compliance
.sw.41t.
employees Lcr,subr.conncW*:cor,,ti.ily,ing,!thit!diip.Wc:.,tcsdn 4nstgladon,mot 6ve ui
t qt,1Con,1pjjx1cw
LDZ
'rats
gngturv, Date Installing Suticon. trac
for (Co -N .a . );QR
Pedonrud
COPY M:
HW Proyidgr (if applicable)
BuildingiOwner at Occupancy
E;miiIiMkiFoi7-n9 Augusti 2001 A- a:5
a
02/24/2006 15:48 951-686-8786 WESTERN INSULATION PAGE 07/21
WESTERN INSULATION, L.P.
4211 Latham Strcct; Riverside, California 92301
TOL (909) 686-8760 Feta (909) 686-8786
CF6R INSULATION CERTIFICATE
THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH
THE CURRENT ENERGY REGULATION, CALIFORNIA ADMINISTRATIVE CODE, TITLE 24,
STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT:
TRACT/PHASE:
CARMELA @ LA QUNITA / PHASE 1
LOT
9
SITE ADDRESS:
------------------------------------------------------------------
81-968 CONTENTO - LA QUINTA, CA
9 S:
BLOWING WOOL
MANUFACTURER:
GREENFIBER THICKNESS: 10.3" R- VALUE: R-38
Cts ING3:
BATTS
MANUFACTURER:
KNAUF THICKNESS: 12" R- VALUE: R-38
I=R- I!2R WALLS:
BATTS
MANUFACTURER:
KNAUF THICKNESS: 6'/4" R- VALUE: R-19
EWMBING BAYS: (0-ATH8
ONM BATTS
MANUFACTURER:
KNAUF THICKNESS;' 3 Ma' R -VALUE: R-11
GENERAL CONTRACTO& TAYLOR WOODROW HOMES
BY:
TITLE:
DATE:
WESTERN INSULATION, L.P•
LICENSE NUMBER: 794484
BY:
TITLE; P
_fICIVUCTION MA
DATE: FEBRUARY 24, 2(