Loading...
05-3404 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 05-00003404 Property Address: 81968 CONTENTO APN: 767-200-011-9 -318741- Application description: ? DWELLING - SINGLE FAMILY Property Zoning: , LOW DENSITY RESIDENTIAL Application valuation: 175002 Ti&t 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT DETACHED Applicant: rchitect or Engineer: ------------ - ---------------- - -------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 352047 / Da�� rector: OWNE -BUILDER DECLARA ION I hereby affirm under penalty of perjury that I am exempt from the Contracto s State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and 10 the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractors) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address:lft LQPERMIT Owner: TAYLOR WOODROW HOMES, INC. 15 CUSHING IRVINE IRVINE, CA 92618 Contractor: TAYLOR WOODROW HOMES INC 15 CUSHING IRVINE, CA 92618 (760)275-0598 Lic. No.: 352047 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 8/03/05 D Q D AUG 0 8 CITY OF LA QUINTA FINANCE - DEPT. ------------------ WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _Lf. -I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier LIBERTY MUTUAL Policy Number WA76SD283614055 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of t> Labor Code shall fo h ith comply with those ' ions. ate: V Applicant —� WARNING: FAILURE TO SECURE WO KERS' C ENSATION COVERAGE IS UNLAWF L, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HU RED THOUSAND DOLLARS 1$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAG AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relatin ' ding construction, anji hereby authorize representatives of this county to enter upon the above- ed prope for inspeyti o s. SAP� nature (Applicant or Agent): Application Number . . . . . 05-00003404 Permit BUILDING PERMIT Additional desc . .. Permit Fee . . . . 905.50 Plan Check Fee 588.58 Issue Date . . . . Valuation . . . . 175002 Expiration Date 1/30/06 Qty Unit Charge Per Extension BASE FEE 639.50 76.00 =--------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 266.00 Permit . . . MECHANICAL Additional desc Permit Fee . . . . 83.50 Plan Check Fee 20.88 Issue Date . . .Valuation 0 Expiration Date 1/30/06 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000'EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/100K BTU 18.00 5.00 --------------------------------=------------------------------------------- .6.5000 EA MECH VENT FAN 32.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 121.92 Plan Check Fee 30.48 Issue Date . . . . Valuation . . . . 0 Expiration -Date 1/30/06 Qty Unit Charge Per Extension BASE FEE 15.00 2685.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 93.98 647.00 ---------------------------------------=---------------=-------------------- .0200 ELEC GARAGE OR NON-RESIDENTIAL 12.94 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 161.25 Plan Check Fee 40.31 Issue Date . . . . Valuation . . . 0 Expiration Date 1/30/06 Qty Unit Charge Per Extension BASE FEE 15'.00 15.00 6.0000 EA PLB FIXTURE 90.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 LQPERMIT LQPERMIT Application Number . . . . 05-00003404 Permit . . . PLUMBING Qty Unit Charge Per Extension 1.00 3.0000 EA PLB WATER.INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 9.00 .7500 EA PLB GAS PIPE >=5 6.75 1.00 15.0000 EA PLB GAS METER ---------------------------------------------------------------------------- 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee 15.00 Plan Check Fee ..00 Issue Date . . . . Valuation . . . . 0 Expiration Date 1/30/06 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 9, PLAN 1B 2685 SF. 2001 CODES. PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. ----------------------=----------------------------------------------------- Other Fees . . . . . . . . . DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 58.86 DIF FIRE PROTECTION -RES 97.00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI),- RES 17.50 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Paid Credited --- - ------------- Due ---------- ---------- -------- 7- ---------- Permit Fee Total 1287.17 .00 .00 1287.17 Plan Check Total 680.25 .00 .00 ,680..25 Other Fee Total 2481.36 .00 .00 2481.36 Grand Total 4448.78 .00, .00 4448.78 LQPERMIT INSTaLATION UjRTWWATE. (Page 3 SIti M63 -5 - DUCT LEAKAGE AND DESIGN DIAGNOSTICS DUCT LBA"Gh,' 1t "OU(3-10M. Pressurization Test Results (CFM @ 25 PA) Test Leakage (CFM)L_E_ Fan Flow If Fan Flow is Calculated as 400 cfrrVton x number oftons, or as 21.7 x Meatinti! Capacity In Thovsa.nds'of�atu/hr, enter Calcqj;!qd�valuo here If f-aln flow .119 measured, enter measuredavalua-here Leakage Fraction v Test Leakage/(M -,F4 ..#Io Leakage/(Measured .glIq jkted n W) Pass if leakage fraction -cA06 . PASS Fall 0 For AEROSOL TYPE SEALANTS ONLY -Th.efoI.l0wIqidl#gpq;1-lc tr.e;.Vqj.w"-completed: Ductfan Prepsud ='on-atroush-inm fvo, .1 asu CFM,) M 64kage CHECK AFM FROM40 WALL: O Yes 0 No 0 Pressure pan test or House pressurization test C3 Yes 0 No 0 Visual. Inspection of Duct Connections 0 a Pass POD 13 MBXOUA.'M,- EXPANSION MVR fM [3 Yes E3 No - T-bermostatic Expansion Valve is installed and Access is - provided, for .inqnotion. Yes is*pAss Fall ACCA i. o Yes o No pomp -Du;t,,Oe n. - _100A.. ftn,,I&o installation matchesmian a. 2. 0 Yes a No 1XV is inst ' ailed orfan. flqw * been verified. Una 7XV, 0 0 verified fan Dow matches Acsi - - ftpm,CF4k Pass Fag MmuredTan,flow - Yes ,f6r:both -1 and2 is aPaps 0 1, the un0ersisned.-verify that -thei.k.bove diagnostic tat results -and the work 1-pedgm;dAssociated with:the test(s)>is:in confomuutce with the ,requirements for compliance .sw.41t. employees Lcr,subr.conncW*:cor,,ti.ily,ing,!thit!diip.Wc:.,tcsdn 4nstgladon,mot 6ve ui t qt,1Con,1pjjx1cw LDZ 'rats gngturv, Date Installing Suticon. trac for (Co -N .a . );QR Pedonrud COPY M: HW Proyidgr (if applicable) BuildingiOwner at Occupancy E;miiIiMkiFoi7-n9 Augusti 2001 A- a:5 a 02/24/2006 15:48 951-686-8786 WESTERN INSULATION PAGE 07/21 WESTERN INSULATION, L.P. 4211 Latham Strcct; Riverside, California 92301 TOL (909) 686-8760 Feta (909) 686-8786 CF6R INSULATION CERTIFICATE THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE CURRENT ENERGY REGULATION, CALIFORNIA ADMINISTRATIVE CODE, TITLE 24, STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT: TRACT/PHASE: CARMELA @ LA QUNITA / PHASE 1 LOT 9 SITE ADDRESS: ------------------------------------------------------------------ 81-968 CONTENTO - LA QUINTA, CA 9 S: BLOWING WOOL MANUFACTURER: GREENFIBER THICKNESS: 10.3" R- VALUE: R-38 Cts ING3: BATTS MANUFACTURER: KNAUF THICKNESS: 12" R- VALUE: R-38 I=R- I!2R WALLS: BATTS MANUFACTURER: KNAUF THICKNESS: 6'/4" R- VALUE: R-19 EWMBING BAYS: (0-ATH8 ONM BATTS MANUFACTURER: KNAUF THICKNESS;' 3 Ma' R -VALUE: R-11 GENERAL CONTRACTO& TAYLOR WOODROW HOMES BY: TITLE: DATE: WESTERN INSULATION, L.P• LICENSE NUMBER: 794484 BY: TITLE; P _fICIVUCTION MA DATE: FEBRUARY 24, 2(