Loading...
04-8236 (SFD)BUILDING & SAFETY DEPARTMENT . 1504 (760).777-7012 ALLE TAMPICO FAX (760) 777-7011 LA 7A, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7 15 3 MAR 312005 BUILDING PERMIT CfTY OF LA GUINTA FINANCE DEPT. Application Number 04-OT00`aa8'�2 6 Date 2/22/05 Property Address .. . . . . . 43062 COR"TE DEL ORO APN: 609-380-997-15 -293233- Application description . . . DWELLING - SINGLE FAMILY DETACHED Property Zoning . . . . . . . LOW DENSITY RESIDENTIAL Application valuation 188445 Owner Contractor ------------------------ PONDEROSA HOMES II, LLC ------------------------ PONDEROSA HOMES II, INC. 6671 OWENS DRIVE 6671 OWENS DRIVE PLEASANTON CA 94588 PLEASANTON CA 94588 (760) 318-7710 WCC: TANNER INSUR WC: 15671603 10/01/05 CSLB: 752884 08/31/06 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . .NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 5.00 FIRE SPRINKLERS NO GARAGE SQ FTG 448.00 PATIO SQ FTG 387.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 3051.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 951.00 Plan Check Fee 618.15 Issue Date . . . . Valuation . . . . 188445 Qty Unit Charge Per Extension BASE FEE 639.50 89.00 3.5000 THOU BLDG 100,001-500,000 311.50 -------------------------------------------=-------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 90.00 Plan Check Fee 22.50 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2.00 9.0000 EA MECH FURNACE <=100K 18.00 2.00 9.0000 EA MECH B/C <=3HP/.100K BTU 18.00 5.00 6.5000 EA MECH VENT FAN 32.50 P.O. Box 1504 VOICE (760) 777-7012 78-495 CALLE TAMPICO y - FAX (760) 777-701 1 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: o4 - I Date:, 3 3D'•05- Applicant: A Architect or Engineer: ;- Applicant's Mailing Address: rchite t or Engineer's Address: ' Zf Ic. No.: G 4�t (3 BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals / `Cpeft and my License i 'n full force and effect. ., � �Qt► icense Class v icense No. V -C �te 3 — b ^ 5 ontractor YO'N OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that.he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects_ the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance �[ of the work for which this permit is issued. 0(I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ce� d. My workers' compensation i ance carrier and � I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ,,,,�aate J -'_6 D ^05 A,. ' ant PO Y�c',(1 pS WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Q Lender's Address` - APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. Signature (Applicant or Agent): l�)y"e, Application Number . . . . . 04-00008236 Page 2 Date 2/22/05 Qty Unit Charge Per Extension 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ---------------------------------------------------------------------------- Permit . . . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 130.75 Plan Check Fee 32.69 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 3051.00, .0350 ELEC NEW RES - 1 OR 2 FAMILY 106.79 448.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.96 ---------------- Permit ------------= . . . . ----------------------------------------------- PLUMBING Additional desc Permit Fee . . . . 190.50- Plan Check Fee 47.63 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 8.00 .7500 EA PLB GAS PIPE >=5 6.00 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit . . . . . . GRADING PERMIT Additional desc ... Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.0.0 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 15,3051 SF. PLAN 2BXR-OPTION BEDROOM 5/BATH 4(+213 SF)W/2 CAR GARAGE (GARAGE 448 SF). PERMIT DOES NOT INCLUDE BLOCK WALLS, POOL, SPA OR DRIVEWAY APPROACH. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 Page 3 Application Number . . . . . 04-00008236 Date 2/22/05 ---------------------------------------------------------7------------------ Other Fees . . . . . . . . . DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 61.82 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 18.84 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary ----------------- Charged ---------- Paid Credited ---------- Due Permit Fee Total 1377.25 ---------- .00 ---------- .00 1377.25 Plan Check Total 720.97 .00 .00 720.97 Other Fee Total 2485.66 .00 .00 2485.66 Grand Total 4583.88 .00 .00 4583.88 01/05/2006 13:37 9496312293 ACTION NOW MPH PAGE 05 E' CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (fight Ducts 8 TXV) CF -4R PROJECT INFORMATION Climate Zone: 15 Project Title; Mosaic (83 Esplanade Project Address: Le Quinta Builder Name: Ponderosa Homes Voice-#: 925-460-8900 Builder Contact: Jeff Nygren Voice #: Project to #: 29323 Sample Group 9: Phase: 10 Lot #: 1 Plan A 2 Address; 43.062 Corte 041-0—m HERS INFORMATION HERS Rater: Scott Johnson Jayme Carden Certification #: CCNSJ614037 CCNJC615157 HERS Firm: Action Now Voice #: 949-631-2274 Address: 2575 Westminster Avenue, Costa Mesa, CA 92627 HERS Provider: CHEERS Voice #: 800-424-3377 HERS Address: 9400 Topanga Canyon Blvd., Chatsworth, CA 91311 HERS RATER COMPLIANCE STATEMENT x T-24 Compliance Credit was Taken for Tight Ducts x T-24 Compliance Credit was Taken for TXV TXV Verified Yes�� The house was; x Tested I Verfied Approved as a part of sample, but was not tested x The installer has prow ed a copy of CF -6R x Air Distribution System Is Fully Ducted (sheetmetal, ductboard or flex duct) Where cloth backed rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at the connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leaks a Testing Results (Maximum 8% putt Leakage) CFA: CFA Leak Max Tested Leak System Indicate the maximum a owe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 X 400 x (Cooling Capacity in Nominal Tons) x (0.08) 21.7 x (Heating Capacit In Thousands of Output BTU per hour) x Measured Fan x .06 uct Pressurization Test Resu IS 5 PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass System of Indicate the marnmum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0,5 x Floor Area x (0.06) for Climate Zones 1 through 7 9 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x Measured Fan Flow x.06 uc Pressurizatlon Test Res u is 5 PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass System of Indicate the maximum a—ow—Ale Duct Leakage and the calculation used: 0.7 x Floor Area x (Q.%) lot Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.08) 21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06) Measured Fan Flow I x .06 uct Pressurization Test Res u t6 5 PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass fan flow L—J Raters Certifying Signature Date 1142006 F2001.02 (4-02) Action Now T-24CF4RTD&TXVmacro.xis 12/29/2005 16:46 FAX 7149212187 ALLIANCE MECHANICAL INSTALLATION CERTIFICATE Site Address Permit Number INSTALLER COMPLIANCE STATEMENT FOR DUCT LEAKAGE Copies to: Builder, HERS Rater, Building Owner at Occupan2X and Bt INSTALLER COMPL CE STATEMENT The building was: ested at Final ✓ ❑ Tested at -Rough -in Q015 CF -6R INSTALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE: O Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior Finishing wall are properly sealed. ❑ If the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection points are properly sealed. O inspect all joints to enswe that no cloth.ba6ed rubber adhesive duct tape is used ✓ ❑ DUCT LEAKAGE REDUCTION Procedures for field veriReatlon and dlaenostic testinz of air distribution systems are available in RACM. ADDendix RC4.3 NEW CONSTRUCTION: Measured = IN Duct Pressurization Test Results (CFM @ 25 Pa) Duct Values I Enter Tested Leakage Flow in CFM:Zi 7 Fan Flow: Calculated (Nomingl: ✓Cooling ✓ eating) or ✓ 0 Measured 2 If Fan Flow is Calculated as 400 cfm/ton x nu d tons or as 21.7 cfm/(kBtu/hr) x Heating 1 A o Capacity in Thousands of Bvdhr, enter total calculated or measured fan flow in CFM here: 7V I/ 3 Pass if Lcaka a Perecntage5 6% fot incl or S 4% at Rough -in: O Pass D Fail 100 x Line # t ! ine # 2 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) MValuesa I Enter Tested Leakage Flow in CFM: Fan Flow: Calculated (Nominal: ✓ Cooling ✓, 0 Heating) or ✓ 0 Measured 4 2 If Fan Flow is Calculated as 400 efmlton x number of tons or as 21.7 cfm/(kBtu/hr) )(Heating Capacity in Thousands of Btulhr, enter total calculated or measured fan flow in CFM here: Pass if Le ge PercentageS 6°o.f inal or 5 4% at Rough -in: 3 1. ❑ Pass D Fail 'A _ 100 x (Line # 1) / (Line # 2)11 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values I Enter Tested Leakage Flow in CFM: Fan Flow: Calculated (Nominal: ✓ D Cooling ✓ ❑ Heating) or ✓ ❑ Measured i 2 If Fan Flow is Calculated as 400 cfin/ton x number of tons or as 21.7 efm/(kBtu/hr) x Heating i Capacity in Thousands of BhVhr, enter total calculated or measured fan flow in CFM here: ✓ f 3 Pass if Leakage Percents es 6% for Final or:5 4% at Rough -in: O Pass Q Fall 100 x Line # 1/ Line # 2 / ❑ I, the undersigned, verify that the above diagnostic test results were performed in a otmanee with the requirements for compliance credit. 1, the undersigned, also certify that the newly install e or retrofit Dis 'bution System Ducts, Plenums and Fans comply with Mandatory requirements specified in Sectio 150 m of 20 Building Energy Efficiency Standards. Installing Subcontractor (Co. Name) OR General Contractor (Co, Name) Residential Compliance Forms March 2005 12/29/2005 16:46 FAX 7149212187 ALLIANCE MECHANICAL 014 INSTALLATION CERTIFICATE CF -6R LOT # F5 PLAN #- Site Address 43-1%22. Mr--bC,- De I OQ:) Permlt Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10.103(a). HVAC SYSTEMS: Heating Equipment Equip Type p yp It . htat tun CEC Certirted Mfr. Name and Model Number b of Identical -.Systems Efficiency (AFUe, etc.) ZCF-1R value Duct Location aisle etc. Duct or Piping FL -value Heisting Load Btu/hr Healing Capacity 81011r) I FURNACENIMN`75Fl 12.0 Z 80$ ATTICo NAC -2 t (2 0 mG ¢2 OLY� Cooling Equipment CEC Certified Mfr. Equip Type Name and Model k . heat um Number k of Identical S stems Efficiency (SEER or EER)Ig aCF- Iltvaluc Location attic etc. Duct R -value Cooling Load Blurhr) Cooling Capein (BIUMI) A/C 12.0 ATTIC JZ -1L NAC -2 t (2 0 mG ¢2 OLY� I . > symbol reads greater than or equal to what is indicated on the CF -IR value. Include both SEER and EER if compliance credit for high EER air conditioner is claimed. 1, the undersigned, veri that equipment listed above is: 1) is the actual equipment installed, 2) equivalent to or more efficient than that spe ft in the ifteate of compliance (Form CF- 1R) submitted for compliance *with the Energy EJTcie y Standards or siden ' I b ildings, and 3) equipment that meets or exceeds the appropriate requirements for manufa Lured devie ( m t .4 lance Efficiency Regulations or Part 6), where applicable. PIUK-] COPY TO: Building Department Hf -XS Rater (if applicable) Building Owner at Occupancy ALLIANCE MECHANICAL CORP. Installing Subcontractor (Co. Name) OR General Contractor (Co, Name) OR Owner Residential Compliance Forms March 2005 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 43-062 CORTE DEL ORO, LOT 15, PHASE 10, LA-QUINTA, CA CEILINGS: TYPE: BLOW MAUNFACTURER: Certainteed THICKNESS: R-30 WALLS: TYPE: BATTS GENE COD BY: PA ONSC MANUFACTURER: Certainteed THICKNESS: R-38 CTO . PONDEROSA HOMES 11, INC. LICENSE!! TITLE: Lea-,;,ol,41�41ei'-; `- BUILDING PRODUCTS A MASCO Company LICENSE # 221517 �'�,'= -C--'-TITLE: ACCOUNT REPRESENTIVE DATE: Certificate of Occupancy G� OFBuilding & Safety Department This Certificate is issued pursuant to the requirements of Section 109 of the California Building Code, certifying that, at the time of issuance, this structure was in compliance with the provisions of the Building Code and the various ordinances of the City regulating building construction and/or use. BUILDING ADDRESS: 43-062 Corte Del -Oro Use classification: Single Family Dwelling Building Permit No.: 04-8236 Occupancy Group: R -3/U1 Type of Construction: VN Land Use Zone: RL Owner of Building: Ponderosa Homes II, Inc Address: 6671 Owens Drive City, ST, ZIP: Pleasanton, CA 94588 lam By: Daniel P. Crawford Jr. Date: 1 /20/05 Building Official POST IN A CONSPICUOUS PLACE