Loading...
05-1148 (BLCK)0 BUILDING &c SAFETY DEPARTMENT P.O. Box 1504 (760).777-7012 OF ��'8- 5 CA TAMPICO FAX (760) 777-7011 D TA LIFORNIA 92253 INSPECTION REQUESTS (760) 777-7153 MAR 312005 BUILDING PERMIT CITY OP'� ®UINTA App icat ' �� . . . . . 05-00001148 Date 3/25/05 Prop r y Address . . . . 43107 CORTE DEL ORO AP -N: 609-380-997-18 -293233- Application description . . . WALL/FENCE Property Zoning . . . . . LOW DENSITY RESIDENTIAL Application valuation . . . . 4075 Owner Contractor ---------------=-------- ------------------------ PONDEROSA HOMES II, INC. PONDEROSA HOMES II, INC. 6671 OWENS DRIVE 6671 OWENS DRIVE PLEASANTON CA 94588 PLEASANTON CA 94588 (760) 318-7710 WCC: TANNER INSUR WC: 156716.03 10/01/05 CSLB: 752884 08/31/06 CCC: B ---------------------------------------------------------------------------- Permit . . . . . WALL/FENCE PERMIT Additional desc Permit Fee . . . . 72.00 P1an'Check Fee .00 Issue Date Valuation . . . . 4075 Qty Unit Charge Per Extension BASE FEE 45.00 3.00 9.0000 THOU BLDG 2,001-25,000 27.00 -------------------------------------------------------------------7-------- Special Notes and Comments 163 L.F. 6' BLOCK WALL, ORCO SYSTEM. Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee.Total 72.00 .00 .00 72.00 Plan Check Total .00 .00 .00 .00 Grand Total 72.00 .00 .00 72.00 P.O. BOX 1504�� VOICE (760) 777-7012 Taf 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 0 _57 ` / ! �� Date: .3•.30 - v� Applicant: Applicant's Mailing Address: L' D &OWA C,7 -o K Architect or Engineer: Architect or Engineer's Address: Lic. No.: BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals ode, and my Licens .s in full force and effect. 5 Z , cense Class IK License No.•// •7 $a Ide'-3 `30—oS Contractor Z OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner. WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issue My workers' compensation insurance car . nd I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Do"3-30^05 Applicant 1001� w0— WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name IV Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 ddys from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspection purposes. mte 3'Jl7"os Signature (Applicant or Agent): ✓ � �^ i t �3-A97 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Tight Ducts & TXV) CF -4R PROJECT INFORMATION Climate Zone: 15 Project Title: Mosaic @ Esplanade Project Address: La Quinta Builder Name:• Ponderosa Homes Voice 0: 926-4eo-8900 Builder Contact: Jeff Nygren Voice Project ID # : 29323 Sample Group*: Phase: 10 Lot #; 1 a Plan #: 2 Address: 43-107 Corte Del Oro HERS INFORMATION HERS Rater: Scott Johnson Joyme Carden Certification # : CCNSJ614037 CCNJC615157 HERS Firm: Action Now Voice if : 949.631-2274 Address: 2575 Westminster Avenue, Costa Mesa. CA 92627 HERS Provider. CHEERS Voice 0: 800.424-3377 HERS Address' 9400 Topanga Canyon Blvd.. Chatsworth, CA 91311 HERS RATER COMPLIANCE STATEMENT Rxx T•24 Compliance Credit was Taken for Tight Ducts T-24 Compliance Credit was Taken for TXV i TXV Verified Yee The house was: x Tested / Verfied Approved as a part of sample, but was not tested x The installer has p—ro—vTed a copy of CF -6R x Air Distribution System is Fully Ducted (sheetmetal, ductboard or flex duct) Where doth backed rubber adhesive duct tape Is Installed, mastic and drawbands are used in combinatlon with cloth backed, rubber adhesive duct tape to seal leaks at the connections. MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic�Leaksa Testing Results (Maximum a°� Duct Leekege) CFA: CFA Leak Mex OTested Leak System Indicate the maowe le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) tan flow 21.7 x (Heating Capacity In Thousands of Output BTU per hour) x (0.06) Measured Fen FIOw X.06 DO Pressurization Test Kesu is PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 61h or Less) Passr77T= Faill System[ of Indicate the maximum a➢owabls Duct leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone a through 15 0.5 x Floor Area x (0.06) for Climate zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.08) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Teat Renu 5 PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass x a Systemof j—j Indicate the msxrmum a owa Is Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity In Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Test Res u is 5 PA) 100 x Test Leakage/ fan flow = % Leakage Check Box for Pass or Fail (Pass = 5%, r Less) Pass ar Raters Certifying Signature fan flow Date 1/02006 F2001-02 (4-02) Action NowT-24CF4RTD&TXVmacro.xls 11.'431 ALLATIO N CERTIFICATE CF -6R U& 1P:) rL- Site Address Permit Number INSTALLER COMPLIANCE STATEMENT FOR DUCT LEAKAGE at Occunancv and INSTALLER COMPYANCE STATEMENT The building was: ✓ ested at Final ✓ ❑ Tested at Rough -in INSTALLER VISUAL INSPECTION AT FINAL CONSTRUCTION STAGE: O Remove at least one supply and one return register, and verify that the spaces between the register boot and the interior finishing wall are properly sealed. 0 1 f the house rough -in duct leakage test was conducted without an air handler installed, inspect the connection points between the air handler and the supply and return plenums to verify that the connection.points are properly sealed. O Inspect all joints to ensure that no cloth backed rubber adhesive duct tape is used ✓ 0 DUCT LEAKAGE REDUCTION ProceduresjorJreld verii Ication and diagnostic testing oJair distribution systems are available in R4 CM, Appendix RC4.3 NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured Values 1 Enter Tested Leakage Flow in CFM: 2 Fan Flow: Calculated (Nominal: ✓ Wooling.VP Beating) or ✓ O Measured If Fan Flow is Calculated 400 efin/ton x nulgiper of tons or as 21.7 afro/(kBtu/hr) x Heating as Ca aci in Thousands of BtWhr enter total calculated or measured fan flow in CFMhere: 1400, Pass if Leakage Percentages 6% for—Final or:5 4% at Rough -in: Pass ❑Fail 3100 x Line # 1 / Line # 2-- NEW CONSTRUCTION: Duct Pressurization Test Results (CFM @ 25 Pa) Measured�` Values I Enter Tested Leakage Flow in CFM: sn :. - .,.. Fan Flow: Calculated (Nominal: ✓Cooling o Heating) or 1 0 Measured 2 If Fan Flow is Calculated as 400 e6ri/ton x num-Ber of tons or as 21.7 cfin/(kBtu/hr) x Heating Capacity in Thousands of BtHRjr enter total calculated or measured fan flow in CFM here: JAfn 3 inal or!9 4% at Roue. -in: Pass if Leakage Percentage:_ ImLine GJ "T ss O Fail 100 x Line # 1 # 2 NEW CONSTRUCTION: Measured - `^ Duct Pressurization Test Results (CFM @ 25 Pa) �= Values 1 Enter Tested Leakage Flow in CFM: - Fan Flow: Calculated (;Nominal. ✓ O Cooling O Beating) or ✓ O Measured 2 If Fan Flow is Calculated as 400 cftn/ton x number of tons or as 21.7 cSn/(kBtu/hr) x Heating Capacity in Thousands of Btu/hr enter total calculated or measured fan flow in CFM here: ✓ 3 I -Pass if Leakage Percentages 6% for Final or <_ 4% at Rough -in: O Pass D Fail 100 x Line # 1 / Line # 2 ./ ❑ 1, the undersigned, verify that the above diagnostic test results were performed in co ormance ith the requirements for compliance'credit. 1, the undersigned, also certify that the newly installer retrofit Distrib n System Ducts, Plenums and Fans comply with Mandatory requirements specified in Section130 0 (m) of 42005 B ' diniz Energy Efficiency Standards._ Sign /I Date Installing Subcontractor (Co. Name) OR l . a 12 I General Contractor (Co. Name) Residential Compliance Forms March 2005 INSTALLATION CERTIFICATE CF -6R LOT Al 195PLAN Site Address 1-3-107 x , Dr'Q Permit Number An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required) After completion of final inspection, a copy must be provided to the building department (upon request) and the building owner at occupancy, per Section 10-103(a). HVAC SYSTEMS: Heating Equipment Equip Type k . heat um CEC Certified W. Name and Model Number b of Identical S stems Efficiency (AFUE, etc.) 2CF-IR value Ductpuel Location anic etc. Duct Or Piping R•volue Heating Load Btu/hr Heating Cap6ciy Btu/hr) FURNACE NI�G2 2- 80% ATTIC R-4-2. D00 Cooling Equipment Equip Type ok . heat um . CEC Certified M. Name and Model Number A of Identical Systems bfficiency i OUR or EER) 2CF-IR value Duct Location anic etc. Duct R -value Cooling Load Btu/hr Cooling Capacity Bra/h( A/C NI�G2 ��-U ATTIC R-- :Z ` ZNY 1. > symbol reads greater than or equal to what is indicated on the CF -1 R value. Include both SEER and EER if compliance credit for high EER air conditioner is claimed. 1, the undersigned, veri that equipment listed above is: 1) is the actual equipment installed, 2) equivalent to or more efficient than that spa 7idenol in the ificate of compliance (Form CF -1R) submitted for compliance with the Energy E�ciehl> Standards ob ildings, and 3) equipment that meets or exceeds the appropriate requirements for•menu/agtured devic ( thX.Viance Efficiency Regulations or Part 6), where applicable. ALLIANCE MECHANICAL CORP. Installing Subcontractor (Co. Name) OR General Contractor (Co. Name) OR Owner COPY T0: Building Depaiftent HERS Rater (if applicable) Building Owner.at Occupancy Residential Compliance Forms March 2005 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, Califomia Administrative Cade, Title 24, State of California, in the building at 43.107 CORTE DEL ORO. LOT 18, PHASE 1o, LA QUINTA, CA CEILINGS: TYPE: BLOW MAUNFACTURER. Certainteed THICKNESS: R-30 WALLS: TYPE. BATTS MANUFACTURER: Certainteed THICKNESS: R-38 GENERAL CONTRACYR: PONDEROSA HOMES 11, INC. LICENSE/8 %Jrl g� BY: ` lir 1 TITLE:�T 3CHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 TITLE: ACCOUNT REPRESENTIVE DATE: