04-4118 (SFD)T44f 4 4Q" 1 . Box 1504 395 CALLE TAMPICO QUINTA, CALIFORNIA 92253 A }7. F&At boT "Number Property Address . . . APN: Application description Property Zoning . . . . Application valuation . Owner BUILDING PERMIT BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7011 INSPECTION REQUESTS (760) 777-7153 04-00004118 Date 5/13/04 . . . 43251 CORTE DEL ORO 609-380-997-7 . -293233- . . . DWELLING - SINGLE FAMILY DETACHED . . . LOW DENSITY RESIDENTIAL . . . 130681 LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111', STE C LA QUINTA, CA LA QUINTA CA 92253 Contractor ------------------------ LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, SUITE C LA QUINTA CA 92253 Qty Unit Charge Per Extension WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 CCC: B --•------------------------ Structure.Information ------------------------- Construction Type TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/LONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CRC 4 BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 447.00 PATIO SQ FTG 45.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2121.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 748.00 Plan Check Fee 486.20 Issue Date . . Valuation 130681 Qty Unit Charge Per Extension BASE FEE 639.50 31.00 3.5000 THOU BLDG 100,001-500,000 108.50 ------------------------------------7--------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee 39.50 Plan Check Fee 9.88 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension P.O. Box 1504• �� VOICE (760) 777-7012 78-495 CALLS TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 4INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: 6q — 9 -fly 1 Date: .:r' .21 -0e -i Applicant: Applicant's Mailing Address: Arc ' t or Enginee : 'ArchE �teeer's Address: 'F-IIAt' 9�' A ci2'(01 Lic. No.: 523q5 P -E ` BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed Zcense rovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals . e, and my License is jn full force and effect. /ilicense Class No. —7a -b 1Da- liti✓' OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a.permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date ' Owner WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 'X I have and will maintain workers' compens tion insurance, as requiredbySection 3700 of the Labor Code, for the performance of the work for which this permit is 11/ � j$suggl._ yly,�grkg'Gcompensation ' urancnbe rrier,�r Wd 111cyl (/ � — I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. ate r'l `�-t ` P Aunt WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Lender's Address APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from dale of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building ;constructi 1nd hereby authorize repres ntatives of this county to enter upon the above mentioned property for inspection purposes. te o (' D ignature (Applicant or Agent): Page 2 Application Number . . . . . 04-00004118 Date 5/13/04 Qty Unit, -Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 19.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 .1.00 6.5000 EA MECH EXHAUST HOOD 6.50 ------------------------------------------------------ Permit . . . . . . ELEC-NEW RESIDENTIAL ------------------------ Additional desc . . Permit Fee . . . . 98.18 Plan Check Fee 24.55 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2121.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 74.24 447.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.94 ---------------------------------------------------------------------------- Permit . . . PLUMBING Additional desc Permit Fee . . . . 152.25 Plan Check Fee 38.06 Issue Date . . . . Valuation. . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00- 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Permit GRADING PERMIT . Additional . . . desc Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . .1 0 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 7. PLAN 3. PERMIT DOES NOT:. Fee summary Charged Permit Fee Total 1052.93 Plan Check Total 558.69 Other Fee Total 2466.68 Grand Total 4078.30 Paid Credited Due ---------- -------=-- ------ ---- .00 .00 1052.93 .00 .00 558.69 .00 .00 2466.68 .00 .00 4078.30 Page 3 Application Number . . . . . 04-00004118 Date 5/13/04 ---------------------------------------------------------------------------- Special Notes and Comments INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH. 7 ------------------------------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 48.62 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 13.06 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged Permit Fee Total 1052.93 Plan Check Total 558.69 Other Fee Total 2466.68 Grand Total 4078.30 Paid Credited Due ---------- -------=-- ------ ---- .00 .00 1052.93 .00 .00 558.69 .00 .00 2466.68 .00 .00 4078.30 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2 CF -6R Site Address: 43-251 Corte Del Oro Permit Number: Tract Number: 29323 Plan #: 3&3X Phase: 6 Lot Number: 7 Project: Esplanade Builder: Lennar Homes An installation certiticate is required to be posted at the building site or made avalible for all appropriate inspections. Atter completion of final inspection, a copy must be provided to the Building Department (upon request) and the building owner at occupancy, per Section 10-103(b). HVAC SYSTEMS: Heating Equipment . of Efficiency Duct Heating Heating Equip. CEC Certifiedr Name Identicle (AFUE, etc.) Location Duct Load Capacity Type and Model Name Systems (>= CF -1 R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) FC USAir 31 OJAV0661 0 AFUE80 attic Cooling Equipment of Efficiency Duct Cooling Cooling Equip. CEC Certifiedr Name Identicle (SEER, etc.) Location Duct Load Capacity Type and Model Number Systems (>=CF -1R) (attic, etc.) R -value (BTU / Hr) (BTU / Hr) HP US Air 563CNX060 attic ---42— i, the undersigned, verity that equipment I;Pf d above is: 1) is the actual equipment Installed, Z) equivalent to or more efficient than that specified in the certifi to f compliance Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential build ng a equ nt that meets or exceeds the appropriate requirements for manufactured devices (from the n c nc R g or Part 6), where here applicable. 40, in Wit— Team Heating & Air Signature, DateInstalling Subcontractor(Co. Name OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: - System of Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 x 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Test Results 2 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) j -1T-24 Compliance Credit was Taken for TXV ` ystem E:J of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) OT -24 Compliance Credit was Taken for TXV TXV was TXV wa., PAGE 1 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2 of 2 CF -6R Site Address: 43-251 Corte Del Oro Permit Number: 0 Tract Number: 29323 Lot Number: 7 Plan #: 3&3X Phase: 6 Project: Esplanade . Builder: Lennar Homes System E� of . Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 5 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) P24 Compliance Credit was Taken for TXV [::� of Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 5 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) (PT -24 Compliance Credit was Taken for TXV ystem E� of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) �T-24 Compliance Credit was Taken for TXV System [� of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) =T-24 Compliance Credit was Taken for TXV x .06 x .06 x .06 x .06 TXV wa: TXV was Pass TXV was inst; Pass TXV was inst I, the undersigned, verify that the above dia nostic test results and the work I performed associated with the test(s) is in conformance with the requirements for pliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the with employees r su ntr tors rtifying that diagnostic testing and installation meet the requirements for compliance credit.) ry 0IL 6� Team Heating & Air Tests ignature, Date Installing Subcontractor(Co. Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro CL Certificate of Insulation Your Home has been insulated with CertainTeed Fiberglass Insulation products, which are designed for today's safety standards and tomorro\,/s energy requirements. Fiberglass is inorganic and therefore permanently noncombustible, so it does not have to be treated with fire -retardant chemicals that will likely lose their effectiveness over tire. It has not been treated with chemicals that can corrode wiring or metal Fiberglass N01 not absorb moiscure nor will it settle over time as may other insulation materials. This also certifies that CertainTeed Fiber Glass Insulation has been professionally installed in this home to provide the following thermal performance: Job Name: Tapestry Q Esplanade Tract: 29323 Phase: 6 Lot :7 Plan: 3 Address: 43 - 251 Corte Del Oro, La Quuola, CA Ceiling Area: R-38 Blown Garage Ceiling: Interior «'aUs: With Living Above Overhangs: Exterior Walls: R-13 Unfaced Baus WiLhing Above Ceiling: Garage Wall: Cantilevered: Inaccessible to Blow Floors Over Unheated Area Subcontractor.. nsulat' ii Co., Inc. 600 S. Vincent, Azusa 91 (626) B 0 U se 09 1 Signed Conchita Ortiz, Secretary/Treasurer --or-- R. Scott Jet 'ns, President—or-- Lou Merola, Director of Operations Officer R- means resistance to heat flow. The higher the R- value, the greater the insulating power. Ask your builder for the fact sheet on R- values. Keep this cenificate with your other valued papers. if you ever sell this home, this certificate should be passed on to the buyer. Deseft ENERGY C A 0 E C Ste'"C" P0. Box 621 Rancho Mirage, CA 92270 Email: DESNRG (MAOL.COM Ph/Fax(760)564-2044 Cell: (760] 250-1852 CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R TAPESTRY @ ESPLANADE PH 6 Project Title 43-251 CORTE DEL ORO LA QUINTA CA. 92253 roc Address TONY PASCANITE 909-275-0204 DATE TESTED 10-13-04 Date LENNAR HOMES Builder Name PLAN 3 1 UNIT Builder Contact Telephone Plan Number ALAN WEAVER 760-880-5504 GROUP 2 HERS R at Telephone Sample Group Number pL �:4� #CCNAW183266 10-14-04 LOT 7-6 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 Copies to: Builder, HERS Provider City/State/Zip: RANCHO MIRAGE, CA. 92270 HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested ® Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) _ Check Box for Pass or Fail (Pass=6% or less) ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Pass Fail