Loading...
04-4137 (SFD)Property Address . . APN: Application description Property Zoning . . . . . . Application valuation . . . Owner �oF.�Q�ra � 92253 _DING PERMIT BUILDING & SAFETY DEPARTMENT (760).777-7012 FAX (760) 777-7.011 INSPECTION REQUESTS (760) 777-7153 �C 04-0.0'004137 Date 5/13/04 43371 CORTE DEL ORO' 609 -380 -997 -2 -293233 - DWELLING - SINGLE FAMILY DETACHED LOW DENSITY RESIDENTIAL 128508 LENNAR HOMES OF CALIFORNIA 78401 HIGHWAY 111, STE C LA QUINTA, CA LA QUINTA CA 92253 Contractor ------------------------ LENNAR HOMES OF CALIFORNIA INC 78401 HIGHWAY 111, SUITE C LA QUINTA CA 92253 WCC: OLD REPUBLIC IN WC: MWC10877600 11/01/04 CSLB: 728102 09/30/04 CCC: B -------------------------- Structure Information ------------------------- Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CRC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 447.00 PATIO SQ FTG 45.00 NUMBER OF UNITS 1.00 FIRST FLOOR SQ FTG 2083.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . Permit Fee . . . . 741.00 Plan Check Fee 120.41 Issue Date . . . . Valuation . . . .. 128508 Qty Unit Charge Per Extension BASE FEE 639.50 29.00 3.5000 THOU BLDG 100,001-500,000 101.50 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL Additional desc Permit Fee . . . . 33.00 Plan Check Fee 2.06 Issue Date Valuation . . . . 0 Qty Unit Charge Per Extension y.. P.O. BOX 1504 • VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153 BUILDING & SAFETY DEPARTMENT Application Number: D li " 413 �L Date:U Applicant: Applicant's Mailing Address: Arc ' t or Engineer: �nA4 U) Architect or En Ineer's A ress: A 1'a7 0 No.: 3,913 US Pr E. BUILDING PERMIT DECLARATIONS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under rovisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Cod nd my License is ' full force and effect. �1� nse C s ice/ns'e/No. 19 7J 102— DDte ���"�' 0 ontractor lC�l✓L ����-�'w/ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). U I am exempt under Sec. , BA P.C. for this reason Date Owner WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensaf insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit iE / r ue , My wort er ' compensation i rance carrieLar� arrier ©/ I G olicy Number _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that theme is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name Al . Lim Lender's Address 1 V APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnity and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building ;construct' n, and hereby authorize re sentatives of this countytoenter upon the above-mentioned property for inspection purposes. e /-d� e� ignature (Applicant or Agent): Application Number . . . . . 04-00004137 Page 2 Date 5/13/04 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 EA MECH FURNACE <=100K 9.00 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 ----------------------------------------------------------------------------- Permit . . . . ELEC-NEW RESIDENTIAL Additional desc Permit Fee . . . . 96.85 Plan Check Fee 6.05 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 2083.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 72.91 447.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 8.94 ---------------------------------------------------------------------------- Permit . . . . . . PLUMBING Additional desc Permit Fee . . . . 146.25 Plan Check Fee 9.14 Issue Date . . . . Valuation 0 Qty Unit Charge Per Extension BASE FEE 15.00 13.00 6.0000 EA PLB FIXTURE 78.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 5.00 .7500 EA PLB GAS PIPE >=5 3.75 1.00 15.0000 EA PLB GAS METER 15.00 ------------------------------------------------------------------ Permit . . . . . . GRADING PERMIT --------- Additional desc Permit Fee . . . . 15.00 Plan Check Fee'. .00 Issue Date . . . . Valuation . . . . 0 Qty Unit Charge Per Extension BASE FEE 15.00 -------------•--------------------------------------------------------------- Special Notes and Comments SFD - LOT 2.. PLAN 2. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR Page 3 Application Number . . . . . 04-00004137 Date 5/13/04 ---------------------------------------------------------------------------- Special Notes and DRIVEWAY APPROACH. REDUCTION APPLIED OF SAME PLAN TYPE. Comments 75% PERMIT FEE FOR MULTIPLE ISSUANCE -------------------------------7-------------------------------------------- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES .00 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 12.04 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 STRONG MOTION (SMI) - RES 12.85 DIF STREET MAINT FAC -RES 15.00 DIF TRANSPORTATION - RES 1098.00 Fee summary Charged ---------- Paid Credited Due ----------------- Permit Fee Total 1032.10 ------------------------------ .00 .00 1032.10 Plan Check Total 137.66 .00 .00 137.66 Other Fee Total 2429.89 .00 .00 2429.89 ;Grand Total 3599.65 .00 .00 3599.65 HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 1 of 2 CF -6R Site Address: 1__43-371 C_ orte DeI Oro Permit Number: Tract Number: 29323 Plan #: 2&2X Phase: 6 Lot Number: 2 \ Project: Esplanade Builder: Lennar Homes An installation certificate is required to be posted at the building site or ma, a avalible for all appropriate inspections. Atter completion of final inspection, a copy must be provided to the Building Department (upon request) and the building owner at occupancy, per Section 10-103(b). \ T HVAC SYSTEMS: ! Heating Equipment , o --Efficiency Equip. CEC CertifiedName Identicle (AFUE, etc.) Type and Model Name Systems (> CFA R) Duct Heating Heating Location Duct Load Capacity (attic, etc.) R -value (BTU / Hr) (BTU / Hr) FC US Air 3 0 066 0 80 attic 4. 1 MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: Systemof I Indicate the maximum owa le Duct Leakage and the calculation used: Cooling Equipment of Efficiency Duct Equip. CEC CertifiedName Identicle (SEER, etc.) Location Type and Model Number Systems (-CF -1 R) (attic, etc.) Cooling Cooling Duct Load Capacity R -value (BTU / Hr) (BTU / Hr) TIP— US Air 563 60 SEER 12 attic ----4-T- OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: Systemof I Indicate the maximum owa le Duct Leakage and the calculation used: 1, the undersigned, verify that equipmentisted above is: 1) is tt a actual equipment installed, 2) equivalent to or more efficient than that specified in the ce ' to of complianceorm CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential uildi equ' nt that meets or exceeds the appropriate requirements for manufactured devices (from the Ap Iia ie y R ons or Part 6), whyre r Team Heating & Air ignature, ate Installing Subcontractor(Co. Name OR General Contractor (Co. Name) OR Owner MINIMUM REQUIREMENTS FOR DUCT LEAKAGE COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) CFA: Systemof I Indicate the maximum owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 x 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 120 fan flow ®0 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage 3.85 0 Check Box for Pass or Fail (Pass = 6% or Less) Pass x I Faid �T-24 Compliance Credit was Taken for TXV TXV was insta e ystem = of �l Indicate the maximum a owa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) fan flow 0 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow x .06 uct Pressurization Test Results 25 A 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) Pass Faill =T-24 Compliance Credit was Taken for TXV TXV was installed PAGE 1 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro :,-' 1-11. HVAC INSTALLATION CERTIFICATE for Tested Duct Leakage & TXV Page 2'of 2 CF -6R Site Address: 43-371 Corte Del Oro Permit Number: 0 Tract Number: 29323 Lot Number: 2 Plan #: 2&2X Phase: 6 Project: Esplanade Builder: Lennar Homes System E� of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) T-24 Compliance Credit was Taken for TXV ystem of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 2 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) pystemT-24 Compliance Credit was Taken for TXV I--] of Indicate the maximum aowa le Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uc Pressurization Test Results 5 PAT - 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) PT-24 Compliance Credit was Taken for TXV YStIystem E=J of Indicate the maximum allowable Duct Leakage and the calculation used: 0.7 x Floor Area x (0.06) for Climate Zone 8 through 15 0.5 x Floor Area x (0.06) for Climate Zones 1 through 7 & 16 400 x (Cooling Capacity in Nominal Tons) x (0.06) 21.7 x (Heating Capacity in Thousands of Output BTU per hour) x (0.06) Measured Fan Flow uct Pressurization Test Results 100 x Test Leakage / Fan Flow = % Leakage Check Box for Pass or Fail (Pass = 6% or Less) =T-24 Compliance Credit was Taken for TXV x .06 x .06 x .06 x.06 TXV was TXV wai Pass TXV was inst TXV was 1, the undersigned, verify that the above diagnostic test results and the work I performed associated with the test(s) is in conformance with the requireme s fo compliance credit. (The builder shall provide the HERS provider a copy of the CF -6R signed by the builder empl ees ub- ntra or certifying that diagnostic testing and installation meet the requirements for compliance credi ) Team Heating & Air esus igna ure, R!te7 Installing Subcontractor(Co. Name Performed OR General Contractor (Co. Name) OR Owner COPY TO: Building Department HERS Provider (if applicable) Building Owner at Occupancy PAGE 2 F2001-01 (4-02) Action Now T-24CF6-RTD&TXV macro M n - ti Certificate of Insulation Your Home has been insulated with CertainTeed Fiberglass Insulation products, which are designed for today's safety standards and tomorrows energy requirements. Fiberglass is inorganic and therefore permanently noncombustible, so it does not have to be treated with fire -retardant chemicals that will likely lose their effectiveness over time. It has not been treated with chemicals that can corrode airing or metal Fiberglass will not absorb moisture nor will it settle o%.er time as may other insulation materials. This also certifies that CertainToed Fiber Glass.[nsulation has been professionally installed in this home ti to provide the following thermal performance: Job Name: Tapestry @ Esplanade Tract: 29323 Pbase: 6 Lot il.: Nk 2 Plan: 211 Address: d3- 371 Carte Del Oro, La Quiota, CA Ceiling Area: R-38 Blown Overhangs: %VfLiving Above Ceiling: Inaccessible to Blow Signed Garage Ceiling: With Luing Above Exterior Walls: Garage Wall: doo s. . Oil. Interior Walls: R-13 Unfaced Batts Cantilevered: Floors Over Unheated Area E CO.; I41c. Conchita Ortiz, Secretary/Treasurer --or-- R. Scoh jVenkans, President--or-- Lou Merola, Director of Operalions Officer R- means resistance to heat flow. The higher the R- value, the greater the insulating power. Ask your builder for the fact sheet on R. values. Keep this certificate with your other valued papers. If you ever sell this home, this certificate should be passed on to the buyer. CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R TAPESTRY @ ESPLANADE PH 6 DATE TESTED 10-13-04 Project Title Date 43-371 CORTE DEL ORO LA QUINTA CA. 92253 LENNAR HOMES -ProLec Address Builder Name TONY PASCANITE 909-275-0204 PLAN 2 1 UNIT Builder Contact Telephone Plan Number ALAN WEAVER 760-880-5504 GROUP 2 HE"ter �^�'°��") Telephone Sample Group Number � #CCNAW183266 10-14-04 LOT 2-6 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 Copies to: Builder, HERS Provider City/State/Zip: RANCHO MIRAGE, CA. 92270 HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested ® Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ ❑ Pass Fail ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ T L�r Damn - - ENERGY - C AD EC services P0. Box 621 Ph/Fax (760) 564-2044 Rancho Mirage, CA 92270 Cell: (7601250-1852 Email: DESNRG aAOL.COM CERTIFICATE OF FIELD VERIFICATION AND DIAGNOSTIC TESTING (Page I of 7) CF -4R TAPESTRY @ ESPLANADE PH 6 DATE TESTED 10-13-04 Project Title Date 43-371 CORTE DEL ORO LA QUINTA CA. 92253 LENNAR HOMES -ProLec Address Builder Name TONY PASCANITE 909-275-0204 PLAN 2 1 UNIT Builder Contact Telephone Plan Number ALAN WEAVER 760-880-5504 GROUP 2 HE"ter �^�'°��") Telephone Sample Group Number � #CCNAW183266 10-14-04 LOT 2-6 Certifying Signature Date Sample Lot Number Firm: DESERT ENERGY SERVICES LLC HERS Provider: CHEERS Street Address: P.O. BOX 621 Copies to: Builder, HERS Provider City/State/Zip: RANCHO MIRAGE, CA. 92270 HERS RATER COMPLIANCE STATEMENT The house was: ❑ Tested ® Approved as part of sample testing but was not tested As the HERS rater providing diagnostic testing and field verification, I certify that the houses identified on this form comply with the diagnostic tested compliance requirements as checked on this form. ❑ The installer has provided a copy of CF -6R (Installation Certificate. ❑ Distribution system is fully ducted(i.e., does not use building cavities as plenums or platform returns in lieu of ducts) ❑ Where cloth backed, rubber adhesive duct tape is installed, mastic and drawbands are used in combination with cloth backed, rubber adhesive duct tape to seal leaks at duct connections. ❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT Duct Diagnostic Leakage Testing Results (Maximum 6% Duct Leakage) Measured Duct Pressurization Test Results (CFM @ 25 Pa) values Test Leakage Flow in CFM If fan flow is calculated as 400cfm/ton x number of tons enter calculated value here If fan flow is measured enter measured value here Leakage Percentage (100 x Test Leakage/Fan Flow) = Check Box for Pass or Fail (Pass=6% or less) ❑ THERMOSTATIC EXPANSION VALVE (TXV) ❑ ❑ Pass Fail ❑ Yes ❑ No Thermostatic Expansion Valve is installed and Access is provided for inspection ❑ ❑ Owner CITY OF LA QUINTA TY DEPARTMENT 7012 INSPECTI EQUEST LINE 1 2004 7 153 of LA Permit Number 04-4137 POST ON JOB IN CONSPICUOUS PLACE INSPECTOR MUST SIGN ALL APPLICABLE SPACES JOB ADDRESS 43-371 CORTE DEL ORO SFD LOT 2 PLAN 2. PERMIT DOES NOT INCLUDE BLOCK WALL, POOL, SPA OR DRIVEWAY APPROACH, TYPE OF INSPECTION I DATE INSP. TEMPORARY POWER SETBACKS U/G PLUMBING / WASTE U/G ELECTRICAL / GROUNDING FOOTINGS / STEEL CONCRETE SLAB DO NOT POUR CONCRETE U TI OV S b ROOF NAIL/ PRE -ROOF OKAY TO WRAP FRAMING COMBINATION ROUGH ELECTRIC ROUGH PLUMBING ROUGH MECHANICAL INSULATION N_ COVER NO WORK UNTIL ABOVE SIGNED INTERIOR GYP BD. DRYWALL EXTERIOR LATH GAS TEST d7 ' o SEPTIC ABANDONMENT SEWER CONNECTION / SEPTIC / GREASE INTERCEPTOR MASONRY INSPECTIONS FOOTINGS / STEEL BOND BEAM POOL / SPA / WATER FEATURE INSPECTIONS PRE-GUNITE / SETBACKS U/G PLUMBING U/G GAS U/G ELECTRICAL PRE -PLASTER (ALARMS/ BARRIERS FINAL INSPECTI NS TEMP. USE OF PERMANENT POWER ELECTRICAL PLUMBING MECHANICAL PUBLIC WORKS DEPARTMENT COMMUNITY DEVELOPMENT DEPT. FINAL / JOB COMPLETED ABOVE APPROVALS DO NOT INCLUDE RIGHT TO TURN ON UTILITIES OR OCCUPY BUILDING