Loading...
13-0537 (AR)P.O. BOX 1504 . 75-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Tityl 4v4 9" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-00000537 Property Address: 79630 CORTE BELLA APN: 609-590-009- - Application description: ADDITION - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 37000 Applicant: Architect or Engineer: NIS LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License'Class: B LiceennseeNo^: 886924 L Date:. tY OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the following reason ISec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ISec. 7044, Business and Professions Code: The Contractors' State License Law does notapplyto an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: I.QPERM IT Owner: WAYNE ALBINGER 79630 CORTE BELLA LA QUINTA, CA 92253 ( Contractor: CARDENAS CONSTRUCT 82553 DOOLITTLE DR INDIO, CA 92201 (760)578-7708 Lic. No.: 886924 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 5/20/13 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Aphave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 903438112 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code. 1 shall forthwith comply with those provisions. Dete: 3 Applicant:�— WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1 . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property -,for inspection purposes. it Da�Signature (Applicantor Age ,0 0 ��j�(/ Application Number 13-00000537 ------ -Structure Information 190SF PATIO ENCLOSURE/VB/RES-3 [CONV] ----- Other struct info . . . . . CODE EDITION 2010 FLOOD ZONE NO 1ST FLOOR. SQUARE FOOTAGE 190.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee . . . . 330.00 Plan Check Fee 214.50 Issue Date . . _ . Valuation . . . 37000 Expiration Date . . 11/12/13 Qty Unit Charge Per Extension BASE FEE 252.00 12.00 6.5000 THOU BLDG 25,001-50,000 78.00 ---------------------------------------------------------------------------- Permit . . . ELECT - ADD/ALT/REM Additional desc . Permit Fee . . . . 18.80 Plan Check Fee 4.70 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/12/13 Qty Unit Charge Per. Extension BASE FEE 15.00 190.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.80 ---------------------------------------------------------------------------- Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 19.50 Plan Check Fee 4.88 Issue Date . . . . Valuation . . . . 0 Expiration Date 11/12/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 ---------------------------------------------------------------------------- Special Notes and Comments 190SF PATIO ENCLOSURE/VB/RES-3/CLASS A -FR [CONVENTIONAL] THIS PERMIT DOES NOT INCLUDE ALTERATION TO THE EXISTING LOAD BEARING AND LATERAL RESISTING CONSTRUCTION. 2010 CALIFORNIA BUILDING CODES. May 16, 2013-1:49:44 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00 LQPEILA11T Application Number . . . . . 13-00000537 ---------------------------------------------------------------------------- Other Fees. ENERGY REVIEW FEE 21.45 STRONG MOTION (SMI) - RES 3.70 Fee'summary ----------------- Charged ---------- Paid -------------------- Credited ---------- Due Permit Fee Total 368.30 .00 .00 368.30 Plat Check Total 224.08 .00 .00 224.08 Other Fee Total 27.15 .00 .00 27.15 Grand Total 619.53 .00 .00 619.53 Bin # 3 C. City of La Quirtta Bullding lit Safety Division Permit # P.O. Box 1504,78-495 Calle Tampico 14.Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet ProjectAddress:'�9 (m30 Owner's Name:. A- P. Number. Address --79 lo✓b ��-�� Legal Description: City, ST, Zip:LA QLL ("& q�s3 Contractor. Address: - l�(o O �1j Project Description: Cr1(jrjJ . City, ST, Zip:1A 1 NTS Telephone: ..& State Lic. #: City Lie, #: Ard , Engr., Designer: L 11t rl .Lz Address:Z� . �� Del l 'b City' ST' Zjp'C ". �— Tdephonel ('t� -'3.;-1B —S4'0 Construction Type:. Ooonpancy: State Lia #: �l (�q Project typc (dude one): New Add'n Alter Repair Demo Name of Contact Person. n . (jj Sy F,: (5c,> Stories: # Unit,: % Telephone # of Contact person: Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS UNE N Submittal Req'd Recd TRACKING PERbffr FEES Plan Sets Pian Check sobadued Item, Amount Structural Cake Reviewed, ready for correctious Ptah Check Deposit. Truss Cala. Called Contact Penes Plan Cheek Balance Title 24 Gla. Pians picked up Construction Flood plain plan Plans resubmitted Mecha" Grading plan 2'4 Review, ready for corre ctionsrissue Eeetrieal Subeontactor list Called Contact Person Plumbing Grant Med Plans pldud cep SAI.I. ` H.OJL Approval Plans resubmitted Grueling IN ROUSE:- Review; ready for correctio aDeveloper Impact Fee Planning Approval Called Contact Person y %b A.I.P P. Pub. Wks. Appr Date of permlt Issue School Fees O Totall mii s J `lblsol3 - (4wv CERTIFICATE OF COMPLIANCE 4���r> hyo Desert Sands Unified School District 47950 Dune Palms Road Q BERMUDA DUNES O RANCHO MIRAGE Cf Date 5/17/13 La Quinta, CA 92253 INDIAN WELLS PDESEFrr No. 31647 (760) 771-8515 `yv? LA LMOUINTA �y 4 Q1 N0 O y� 0 Owner Albinger, Wayne APN # 609-590-009 Address 79-630 Corte Bella Jurisdiction La Quinta City La Quinta Zip Permit # Tract # No. of Units 1 Type Single Family Residence Lot # No. Street S.F. Lot # No. Street S.F. Unit 1 79-630 Corte Bella 190 Unit 6 Unit 2 Unit 7 Unit 3 Unit 8 Unit 4 Unit 9 Unit 5 Unit 10 Comments At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason: Residential Addition 500 Sq Feet or Less EXEMPT This certifies that school facility fees imposed pursuant to in the amount of $0.00 X 190 S.F. or $0.00 have been paid for the property listed above and that building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued. Fees Paid By Wayne Albinger Check No. 0.00 Bank Name/Recipient of Certificate Telephone Funding Residential By Dr. Gary Rutherford Superintendent Fee collected /exempted by Es p Lara Payment Recd .K. Over/Under Signature NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier. NOTICE: This Document NOT VALID without embossed seal Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting OIL BUILDING ENERGY ANALYSIS REPORT PROJECT: ALBINGER"s Residence 79630 Corte Bella La Quinta, Ca 92253 Project Designer: GLS Architecture Group 74991 Joni Dr. # 9 Palm Desert, Ca 92211 760.340.3528 Report Prepared by: ARMANDO CHAVEZ GLS Architecture Group 74991 JONI DR SUITE #9 PALM DESERT, CA 92260 760 278.1840 I �� CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED Job Number: FOR CONSTRUCTION 2013 -GLS -13 I DATE Date: 4/18/2013 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. I EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 I TABLE OF CONTENTS I Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary EnergyPro 5.1 by EnergySoft Job Number: ID: 2013 -GLS -13 User Number: 5553 1 2 3 9 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name ALBINGER"s Residence Building Type 21 Single Family ❑ Addition Alone ❑ Multi Family ® Existing+ Addition/Alteration Date 4/18/2013 Project Address 79630 Corte Bella La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,927 Addition 190 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area' Special Cavity (ft) Features (see Part 2 of 5) Status Slab Unheated Slab -on -Grade None 2,737 Perim = 0' Existing Roof Wood Framed Attic R-19 2,737 Existing Wall Wood Framed R-13 2,515 Existing Slab Unheated Slab -on -Grade None 190 Perim = 0' New Roof Wood Framed Attic R-38 190 Altered Wall Wood Framed R-19 62 New FENESTRATION U- Orientation Area(fe) Factor Exterior SHGC Overhang Sidef ins Shades Status Front (NE) 43.0 0.710 0.73 none none Bug Screen Existing Left (SE) 45.0 0.710 0.73 none none Bug Screen Existing Rear (SIM 90.0 0.710 0.73 none none Bug Screen Existing Rear (SW) 120.0 0.710 0.73 none none Bug Screen Removed Rear (SM 40.0 0.710 0.73 none none Bug Screen Existing Right (NW) 130.0 0.710 0.73 none none Bug Screen Existing Right (NW) 80.0 0.710 0.73 none none Bug Screen Removed Right (NW) 128.0 0.370 0.32 none none Bug Screen New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status EXISTING Ducted Ducted Attic, Roof Ins 4.2 Existing WATER HEATING Ot . Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13 Page 3 of 11 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name ALBINGER"s Residence Building Type ® Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 1411812013 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Existing Roof 190 has a U -Factor greater than the Vintage Defaults. Field verification is required. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Ener Pro 5.1 by Ener Soft User Number.- 5553 RunCode: 2013-04-18710:58:53 /D: 2013 -GLS -13 Pa e 4 of 11 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type 2 Single Family ❑ Addition Alone Date ALBINGER"s Residence ❑ Multi Family 2 Existing+ Addition/Alteration 1411812013 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kgtu/ft2-yr Space Heating 8.53 4.79 3.74 Space Cooling 185.02 149.83 35.19 Fans 32.28 25.94 6.34 Domestic Hot Water 12.35 12.35 0.00 Pumps 0.00 0.00 0.00 Totals 238.18 192.90 45.27 Percent Better Than Standard: 19.0% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (NE) 628 43 Fuel Available at Site: Natural Gas (SE) 963 45 Raised Floor Area: 0 (StM 440 130 Slab on Grade Area: 2,927 (NM 1,022 258 Average Ceiling Height: 10.0 Roof 2,927 0 Fenestration Average U -Factor: 0.62 TOTAL: 476 Average SHGC: 0.62 Fenestration/CFA Ratio: 16.3 REMARKS ALL PROPOSED INPUT DATA USED /N THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY. STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the�� Efficiency Standards of the California Code of Regulations. 'r The documentation author hereby certifies that the documentation is accurate and.complete- Documentation Author Company GLS Architecture Group 4/18/2013 74991 JONI DR SUITE #9 ARMANDO CHAVEZ Address Name City/State/ZipCity/State/Zip PALM DESERT, CA 92260 Phone 760 278.1840 Si ed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Deer or Owner (per Business & Professions Code) Company GLS Architecture Group Address 74991 Joni Dr. # 9 Name City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 igned License # Date Ener Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Page 5 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name ALBINGER"s Residence Building Type ® Single Family ❑ Addition Alone ❑ Multi Family 2 Existing+ Addition/Alteration Date 1411812013 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Slab 2,737 0.730 None 0 180 Existing 4.4.7 -Al Roof 2,737 0.049 R-19 0 0 Existing 4.2.1-A4 Wall 585 0.102 R-13 45 90 Existing 4.3.1-A3 Wall 918 0.102 R-13 135 90 Existing 4.3.1-A3 Wall 310 0.102 R-13 225 90 Existing 4.3.1-A3 Wall 702 0.102 R-13 315 90 Existing 4.3.1-A3 Wall 60 0.102 R-13 315 90 Removec 4.3.1-A3 Wall 99 0.102 R-13 225 90 Removec 4.3.1-A3 Wall 60 0.102 R-13 315 90 Removec 4.3.1-A3 Slab 190 0.730 None 0 180 New 4.4.7-A1 Roof 190 0.025 R-38 0 0 Altered 4.2.1-A21 (E=4.2.1 -A1 Wall 62 R -19 315 90 New 4.3.1-A5 I FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 15.0 0.710 Default 0.73 1 Default 45 Existing Double Metal Clear 2 Window 14.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 3 Window 14.0 0.710 Default 0.73 Default 45 Existing Double Metal Clear 4 Window 15.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 5 Window 15.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 6 Window 15.0 0.710 Default 0.73 Default 135 Existing Double Metal Clear 7 Window 15.01 0.710 Default 0.73 Default 225 Existing Double Metal Clear 8 Window 15.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear 9 Window 15.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear 10 Window 15.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear 11 Window 15.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear 12 Window 15.0 0.710 1 Default 0.73 Default 225 Existing Double Metal Clear 13 Window 15.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear 14 Window 15.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear 15 Window 40.0 0.710 Default 0.73 Default 225 Existing Double Metal Clear RELOC. 16 Window 10.0 0.710 Default 0.73 Default 3151 Existing Double Metal Clear (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hot Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number., 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Page 6 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name ALBINGER"s Residence Building Type 0 Single Family ❑ Addition Alone ❑ Multi Family G3 Existing+ Addition/Alteration Date 1411812013 OPAQUE SURFACE DETAILS Surface U- Type Area Factor Insulation Joint Appendix Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments FENESTRATION SURFACE DETAILS ID Area U -Factor SHGC2 Azm Status Glazing Type Location/Comments 17 -Type Window 6.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 18 Window 6.0 0.710 Default 0.73 Default 3151 Existing Double Metal Clear 19 Window 25.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 20 Window 8.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 21 Window 6.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 22 Window 6.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 23 Window 8.0 0.710 1 Default 0.73 Default 315 Existing Double Metal Clear 24 Window 40.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 25 Window 15.0 0.710 Default 0.73 Default 315 Existing Double Metal Clear 26 Window 40.0 0.710 Default 0.73 Default 315 Removed Double Metal Clear 27 Window 30.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear 28 Window 30.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear 29 Window 1 30.0 0.710 Default 0.73 Default 225 Removed Double Metal Clear 30 Window 40.0 0.710 Default 0.73 Default 315 Removed Double Metal Clear 31 Window 128.0 0.370 NFRC 0.32 NFRC 315 New CONTRACTOR VALUE .37-.32 (1) U -Factor Type: 2 SHGC Type: 116-A = Default Table from Standards, NFRC = Labeled Value 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hang Left Fin Right Fin Len H t LExt RExt Dist Len H t Dist Len H t 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 23 Bug Screen 0.76 24 Bug Screen 0.76 25 Bug Screen 0.76 26 Bug Screen 0.76 27 Bug Screen 0.76 28 Bug Screen 0.76 29 Bug Screen 0.76 30 Bug Screen 0.76 31 16ug Screen 0.76 Ener Pro 5.1 by Ener Soft User Number 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Pa e 7 of 11 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name ALBINGER"s Residence Building Type 2 Single Family ❑ Addition Alone ❑ Multi Family 2 Existing+ Addition/Alteration Date 4/18/2013 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built EXISTING EXISTING 2,737 27,370 2003 Addition 190 1,900 Totals 190 2,737 0 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status EXISTING 2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status EXISTING Ducted Ducted Attic, Roof Ins 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status Standard Gas 50 gal or Le 1 Small Gas Kitchen Pipe Ins 40,000 50 0.58 Na n/a Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft 0 0 QPipe — System Name Length Pipe Diameter Insul. Thick. Qty. HP Plenum Outside Buried 13 El Energ Pro 5.1 by Energ Soft User Number: 5553 RunCode: 2013-0418710:58:53 ID: 2013 -GLS -13 Pa e 8 of 11 MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name ALBINGER"s Residence Date 1411812013 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. 150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13 Page 9 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R Project Name Date ALBINGER"s Residence 1411812013 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. 150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13 Page 10 of 11 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ALBINGER"s Residence 1411812013 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or'bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 /D: 2013 -GLS -13 Page 11 of 11