13-0537 (AR)P.O. BOX 1504 .
75-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Tityl 4v4 9"
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: 13-00000537
Property Address: 79630 CORTE BELLA
APN: 609-590-009- -
Application description: ADDITION - RESIDENTIAL
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 37000
Applicant: Architect or Engineer:
NIS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect.
License'Class: B LiceennseeNo^: 886924
L
Date:. tY
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that 1 am exempt from the Contractor's State License Law for the
following reason ISec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001.:
(_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ISec.
7044, Business and Professions Code: The Contractors' State License Law does notapplyto an owner of
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
1 ) I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
I.QPERM IT
Owner:
WAYNE ALBINGER
79630 CORTE BELLA
LA QUINTA, CA 92253
(
Contractor:
CARDENAS CONSTRUCT
82553 DOOLITTLE DR
INDIO, CA 92201
(760)578-7708
Lic. No.: 886924
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/20/13
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
Aphave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 903438112
_ I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should become subject to the workers' compensation provisions of Section
3700 of the Labor Code. 1 shall forthwith comply with those provisions.
Dete: 3 Applicant:�—
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1 . Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building construction, and hereby authorize representatives
of this county to enter upon the above-mentioned property -,for inspection purposes.
it
Da�Signature (Applicantor Age ,0 0 ��j�(/
Application Number 13-00000537
------ -Structure Information 190SF PATIO ENCLOSURE/VB/RES-3 [CONV] -----
Other struct info . . . . . CODE EDITION 2010
FLOOD ZONE NO
1ST FLOOR. SQUARE FOOTAGE 190.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc
Permit Fee . . . . 330.00 Plan Check Fee 214.50
Issue Date . . _ . Valuation . . . 37000
Expiration Date . . 11/12/13
Qty Unit Charge Per Extension
BASE FEE 252.00
12.00 6.5000 THOU BLDG 25,001-50,000 78.00
----------------------------------------------------------------------------
Permit . . . ELECT - ADD/ALT/REM
Additional desc .
Permit Fee . . . . 18.80 Plan Check Fee 4.70
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/12/13
Qty Unit Charge Per. Extension
BASE FEE 15.00
190.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 3.80
----------------------------------------------------------------------------
Permit . . . MECHANICAL
Additional desc .
Permit Fee . . . . 19.50 Plan Check Fee 4.88
Issue Date . . . . Valuation . . . . 0
Expiration Date 11/12/13
Qty Unit Charge Per Extension
BASE FEE 15.00
1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50
----------------------------------------------------------------------------
Special Notes and Comments
190SF PATIO ENCLOSURE/VB/RES-3/CLASS
A -FR [CONVENTIONAL] THIS PERMIT DOES NOT
INCLUDE ALTERATION TO THE EXISTING LOAD
BEARING AND LATERAL RESISTING
CONSTRUCTION. 2010 CALIFORNIA BUILDING
CODES.
May 16, 2013-1:49:44 PM AORTEGA
----------------------------------------------------------------------------
Other Fees . . . . . . . . BLDG STDS ADMIN (SB1473) 2.00
LQPEILA11T
Application Number
. . . . .
13-00000537
----------------------------------------------------------------------------
Other Fees.
ENERGY REVIEW
FEE
21.45
STRONG MOTION
(SMI) - RES
3.70
Fee'summary
-----------------
Charged
----------
Paid
--------------------
Credited
----------
Due
Permit Fee Total
368.30
.00
.00
368.30
Plat Check Total
224.08
.00
.00
224.08
Other Fee Total
27.15
.00
.00
27.15
Grand Total
619.53
.00
.00
619.53
Bin #
3 C.
City of La Quirtta
Bullding lit Safety Division
Permit #
P.O. Box 1504,78-495 Calle Tampico
14.Quinta, CA 92253 - (760) 777-7012
Building Permit Application and Tracking Sheet
ProjectAddress:'�9 (m30
Owner's Name:.
A- P. Number.
Address --79 lo✓b ��-��
Legal Description:
City, ST, Zip:LA QLL ("& q�s3
Contractor.
Address: - l�(o O �1j
Project Description: Cr1(jrjJ .
City, ST, Zip:1A 1 NTS
Telephone: ..&
State Lic. #: City Lie, #:
Ard , Engr., Designer: L 11t rl .Lz
Address:Z� . �� Del l 'b
City' ST' Zjp'C ". �—
Tdephonel ('t� -'3.;-1B
—S4'0
Construction Type:. Ooonpancy:
State Lia #: �l (�q
Project typc (dude one): New Add'n Alter Repair Demo
Name of Contact Person.
n .
(jj Sy F,: (5c,> Stories: # Unit,: %
Telephone # of Contact person:
Estimated Value of Project:
APPLICANT: DO NOT WRITE BELOW THIS UNE
N
Submittal
Req'd
Recd
TRACKING PERbffr FEES
Plan Sets
Pian Check sobadued Item, Amount
Structural Cake
Reviewed, ready for correctious Ptah Check Deposit.
Truss Cala.
Called Contact Penes Plan Cheek Balance
Title 24 Gla.
Pians picked up Construction
Flood plain plan
Plans resubmitted Mecha"
Grading plan
2'4 Review, ready for corre ctionsrissue Eeetrieal
Subeontactor list
Called Contact Person Plumbing
Grant Med
Plans pldud cep
SAI.I.
`
H.OJL Approval
Plans resubmitted Grueling
IN ROUSE:-
Review; ready for correctio aDeveloper Impact Fee
Planning Approval
Called Contact Person y %b A.I.P P.
Pub. Wks. Appr
Date of permlt Issue
School Fees
O Totall mii s
J `lblsol3 - (4wv
CERTIFICATE OF COMPLIANCE 4���r> hyo
Desert Sands Unified School District
47950 Dune Palms Road Q BERMUDA DUNES O
RANCHO MIRAGE Cf
Date 5/17/13 La Quinta, CA 92253 INDIAN WELLS
PDESEFrr
No. 31647 (760) 771-8515 `yv? LA LMOUINTA �y
4 Q1 N0 O y�
0
Owner
Albinger, Wayne
APN # 609-590-009
Address
79-630 Corte Bella
Jurisdiction La Quinta
City
La Quinta Zip
Permit #
Tract #
No. of Units 1
Type
Single Family Residence
Lot # No. Street
S.F.
Lot # No. Street S.F.
Unit 1
79-630 Corte Bella
190 Unit 6
Unit 2
Unit 7
Unit 3
Unit 8
Unit 4
Unit 9
Unit 5
Unit 10
Comments
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports, covered patios/walkways, residential additions under
500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking, eating or sanitation) or replacement mobile
homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
EXEMPT
This certifies that school facility fees imposed pursuant to
in the amount of $0.00 X 190 S.F. or $0.00 have been paid for the property listed above and that
building permits and/or Certificates of Occupancy for this square footage in this proposed project may now be issued.
Fees Paid By Wayne Albinger Check No. 0.00
Bank Name/Recipient of Certificate Telephone
Funding Residential
By Dr. Gary Rutherford
Superintendent
Fee collected /exempted by Es p Lara
Payment Recd
.K.
Over/Under
Signature
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will serve to notify you that the 90 -day approval period in which you may protest the fees
or other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
NOTICE: This Document NOT VALID without embossed seal
Embossed Original - Building Department Applicant Copy - Applicant/Receipt Copy - Accounting
OIL
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
ALBINGER"s Residence
79630 Corte Bella
La Quinta, Ca 92253
Project Designer:
GLS Architecture Group
74991 Joni Dr. # 9
Palm Desert, Ca 92211
760.340.3528
Report Prepared by:
ARMANDO CHAVEZ
GLS Architecture Group
74991 JONI DR SUITE #9
PALM DESERT, CA 92260
760 278.1840
I ��
CITY OF LA QUINTA
BUILDING & SAFETY DEPT.
APPROVED
Job Number: FOR CONSTRUCTION
2013 -GLS -13 I DATE
Date:
4/18/2013
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC — www.energysoft.com.
I EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13
I TABLE OF CONTENTS I
Cover Page
Table of Contents
Form CF -1 R Certificate of Compliance
Form MF -1 R Mandatory Measures Summary
EnergyPro 5.1 by EnergySoft Job Number: ID: 2013 -GLS -13 User Number: 5553
1
2
3
9
PERFORMANCE CERTIFICATE: Residential Part 1 of 5
CF -1 R
Project Name
ALBINGER"s Residence
Building Type 21 Single Family ❑ Addition Alone
❑ Multi Family ® Existing+ Addition/Alteration
Date
4/18/2013
Project Address
79630 Corte Bella La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,927
Addition
190
# of Stories
1
FIELD INSPECTION ENERGY CHECKLIST
❑ Yes El No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form.
El Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details.
INSULATION
Construction Type
Area' Special
Cavity (ft) Features (see Part 2 of 5)
Status
Slab Unheated Slab -on -Grade
None 2,737 Perim = 0'
Existing
Roof Wood Framed Attic
R-19 2,737
Existing
Wall Wood Framed
R-13 2,515
Existing
Slab Unheated Slab -on -Grade
None 190 Perim = 0'
New
Roof Wood Framed Attic
R-38 190
Altered
Wall Wood Framed
R-19 62
New
FENESTRATION U-
Orientation Area(fe) Factor
Exterior
SHGC Overhang Sidef ins Shades
Status
Front (NE) 43.0 0.710
0.73 none none Bug Screen
Existing
Left (SE) 45.0 0.710
0.73 none none Bug Screen
Existing
Rear (SIM 90.0 0.710
0.73 none none Bug Screen
Existing
Rear (SW) 120.0 0.710
0.73 none none Bug Screen
Removed
Rear (SM 40.0 0.710
0.73 none none Bug Screen
Existing
Right (NW) 130.0 0.710
0.73 none none Bug Screen
Existing
Right (NW) 80.0 0.710
0.73 none none Bug Screen
Removed
Right (NW) 128.0 0.370
0.32 none none Bug Screen
New
HVAC SYSTEMS
Ot . Heating Min. Eff Cooling Min. Eff Thermostat
Status
2 Central Furnace 78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
EXISTING Ducted
Ducted Attic, Roof Ins 4.2
Existing
WATER HEATING
Ot . Type Gallons Min. Eff Distribution
Status
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13
Page 3 of 11
PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R
Project Name
ALBINGER"s Residence
Building Type ® Single Family ❑ Addition Alone
1 ❑ Multi Family ® Existing+ Addition/Alteration
Date
1411812013
SPECIAL FEATURES INSPECTION CHECKLIST
The enforcement agency should pay special attention to the items specified in this checklist. These items require special written
justification and documentation, and special verification to be used with the performance approach. The enforcement agency
determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of
the special justification and documentation submitted.
The Existing Roof 190 has a U -Factor greater than the Vintage Defaults. Field verification is required.
HERS REQUIRED VERIFICATION
Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a
completed CF -4R form for each of the measures listed below for final to be given.
Ener Pro 5.1 by Ener Soft User Number.- 5553 RunCode: 2013-04-18710:58:53 /D: 2013 -GLS -13 Pa e 4 of 11
PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R
Project Name
Building Type 2 Single Family ❑ Addition Alone
Date
ALBINGER"s Residence
❑ Multi Family 2 Existing+ Addition/Alteration
1411812013
ANNUAL ENERGY USE SUMMARY
Standard Proposed Margin
TDV kgtu/ft2-yr
Space Heating 8.53 4.79 3.74
Space Cooling 185.02 149.83 35.19
Fans 32.28 25.94 6.34
Domestic Hot Water 12.35 12.35 0.00
Pumps 0.00 0.00 0.00
Totals 238.18 192.90 45.27
Percent Better Than Standard: 19.0%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Fenestration
Building Front Orientation: (NE) 45 deg Ext. Walls/Roof Wall Area Area
Number of Dwelling Units: 1.00 (NE) 628 43
Fuel Available at Site: Natural Gas (SE) 963 45
Raised Floor Area: 0 (StM 440 130
Slab on Grade Area: 2,927 (NM 1,022 258
Average Ceiling Height: 10.0 Roof 2,927 0
Fenestration Average U -Factor: 0.62 TOTAL: 476
Average SHGC: 0.62 Fenestration/CFA Ratio: 16.3
REMARKS
ALL PROPOSED INPUT DATA USED /N THIS CALCULATION WAS PROVIDED BY THE PLANS PREPARER. ANY ALTERATION OR DEVIATION
FROM THIS CALCULATION WILL BE GENERAL CONTRACTOR RESPONSABILITY.
STATEMENT OF COMPLIANCE
This certificate of compliance lists the building features and specifications needed
to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the��
Efficiency Standards of the California Code of Regulations.
'r
The documentation author hereby certifies that the documentation is accurate and.complete-
Documentation Author
Company GLS Architecture Group
4/18/2013
74991 JONI DR SUITE #9 ARMANDO CHAVEZ
Address Name
City/State/ZipCity/State/Zip PALM DESERT, CA 92260 Phone 760 278.1840 Si ed Date
The individual with overall design responsibility hereby certifies that the proposed building design represented in this set
of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and
with any other calculations submitted with this permit application, and recognizes that compliance using duct design,
duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require
installer testing and certification and field verification by an approved HERS rater.
Deer or Owner (per Business & Professions Code)
Company GLS Architecture Group
Address 74991 Joni Dr. # 9 Name
City/State/Zip Palm Desert, Ca 92211 Phone 760.340.3528 igned License # Date
Ener Pro 5.1 by Ener Soft User Number: 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Page 5 of 11
CERTIFICATE OF COMPLIANCE:
Residential
(Part 4 of 5) CF -1 R
Project Name
ALBINGER"s Residence
Building Type ® Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
1411812013
OPAQUE SURFACE DETAILS
Surface
Type Area
U- Insulation Joint Appendix
Factor Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
Slab
2,737
0.730 None
0
180 Existing 4.4.7 -Al
Roof
2,737
0.049 R-19
0
0 Existing 4.2.1-A4
Wall
585
0.102 R-13
45
90 Existing 4.3.1-A3
Wall
918
0.102 R-13
135
90 Existing 4.3.1-A3
Wall
310
0.102 R-13
225
90 Existing 4.3.1-A3
Wall
702
0.102 R-13
315
90 Existing 4.3.1-A3
Wall
60
0.102 R-13
315
90 Removec 4.3.1-A3
Wall
99
0.102 R-13
225
90 Removec 4.3.1-A3
Wall
60
0.102 R-13
315
90 Removec 4.3.1-A3
Slab
190
0.730 None
0
180 New 4.4.7-A1
Roof
190
0.025 R-38
0
0 Altered 4.2.1-A21 (E=4.2.1 -A1
Wall
62
R -19
315
90 New 4.3.1-A5
I
FENESTRATION SURFACE DETAILS
ID
Type
Area U -Factor
SHGC
Azm Status
Glazing Type Location/Comments
1
Window
15.0 0.710 Default
0.73 1 Default
45 Existing
Double Metal Clear
2
Window
14.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
3
Window
14.0 0.710 Default
0.73 Default
45 Existing
Double Metal Clear
4
Window
15.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
5
Window
15.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
6
Window
15.0 0.710 Default
0.73 Default
135 Existing
Double Metal Clear
7
Window
15.01 0.710 Default
0.73 Default
225 Existing
Double Metal Clear
8
Window
15.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear
9
Window
15.0 0.710 Default
0.73 Default
225 Removed
Double Metal Clear
10
Window
15.0 0.710 Default
0.73 Default
225 Removed
Double Metal Clear
11
Window
15.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear
12
Window
15.0 0.710 1 Default
0.73 Default
225 Existing
Double Metal Clear
13
Window
15.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear
14
Window
15.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear
15
Window
40.0 0.710 Default
0.73 Default
225 Existing
Double Metal Clear RELOC.
16
Window
10.0 0.710 Default
0.73 Default
3151 Existing
Double Metal Clear
(1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value
2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type SHGC
Window
Hot Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
1
Bug Screen
0.76
2
Bug Screen
0.76
3
Bug Screen
0.76
4
Bug Screen
0.76
5
Bug Screen
0.76
6
Bug Screen
0.76
7
Bug Screen
0.76
8
Bug Screen
0.76
9
Bug Screen
0.76
10
Bug Screen
0.76
11
Bug Screen
0.76
12
Bug Screen
0.76
13
Bug Screen
0.76
14
Bug Screen
0.76
15
Bug Screen
0.76
16
Bug Screen
0.76
Ener
Pro 5.1 by Ener Soft User Number., 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Page 6 of 11
CERTIFICATE OF COMPLIANCE:
Residential (Part 4 of 5) CF -1 R
Project Name
ALBINGER"s Residence
Building Type 0 Single Family ❑ Addition Alone
❑ Multi Family G3 Existing+ Addition/Alteration
Date
1411812013
OPAQUE SURFACE DETAILS
Surface U-
Type Area Factor
Insulation Joint Appendix
Cavity Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments
FENESTRATION SURFACE DETAILS
ID
Area
U -Factor
SHGC2
Azm Status Glazing Type Location/Comments
17
-Type
Window 6.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
18
Window 6.0
0.710 Default
0.73 Default
3151 Existing Double Metal Clear
19
Window 25.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
20
Window 8.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
21
Window 6.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
22
Window 6.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
23
Window 8.0
0.710 1 Default
0.73 Default
315 Existing Double Metal Clear
24
Window 40.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
25
Window 15.0
0.710 Default
0.73 Default
315 Existing Double Metal Clear
26
Window 40.0
0.710 Default
0.73 Default
315 Removed Double Metal Clear
27
Window 30.0
0.710 Default
0.73 Default
225 Removed Double Metal Clear
28
Window 30.0
0.710 Default
0.73 Default
225 Removed Double Metal Clear
29
Window 1 30.0
0.710 Default
0.73 Default
225 Removed Double Metal Clear
30
Window 40.0
0.710 Default
0.73 Default
315 Removed Double Metal Clear
31
Window 128.0
0.370 NFRC
0.32 NFRC
315 New CONTRACTOR VALUE .37-.32
(1) U -Factor Type:
2 SHGC Type:
116-A = Default Table from Standards, NFRC = Labeled Value
116-B = Default Table from Standards, NFRC = Labeled Value
EXTERIOR SHADING DETAILS
ID
Exterior Shade Type
SHGC
Window
H t Wd
Ove hang Left Fin Right Fin
Len H t LExt RExt Dist Len H t Dist Len H t
17
Bug Screen
0.76
18
Bug Screen
0.76
19
Bug Screen
0.76
20
Bug Screen
0.76
21
Bug Screen
0.76
22
Bug Screen
0.76
23
Bug Screen
0.76
24
Bug Screen
0.76
25
Bug Screen
0.76
26
Bug Screen
0.76
27
Bug Screen
0.76
28
Bug Screen
0.76
29
Bug Screen
0.76
30
Bug Screen
0.76
31
16ug Screen
0.76
Ener
Pro 5.1 by Ener Soft
User Number 5553 RunCode: 2013-04-18710:58:53 ID: 2013 -GLS -13 Pa e 7 of 11
CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R
Project Name
ALBINGER"s Residence
Building Type 2 Single Family ❑ Addition Alone
❑ Multi Family 2 Existing+ Addition/Alteration
Date
4/18/2013
BUILDING ZONE INFORMATION
System Name Zone Name
Floor Area
New Existing Altered Removed Volume Year Built
EXISTING EXISTING
2,737
27,370 2003
Addition
190
1,900
Totals 190 2,737 0 0
HVAC SYSTEMS
System Name Qty. Heating Type
Min. Eff. Cooling Type Min. Eff. Thermostat Type Status
EXISTING 2 Central Furnace
78% AFUE Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
System Name Heating
Duct
Cooling Duct Location R -Value
Ducts
Tested? Status
EXISTING Ducted Ducted Attic, Roof Ins 4.2
❑ Existing
WATER HEATING SYSTEMS
S stem Name
Qty-
Type
Distribution
Rated
Input
Btuh
Tank
Cap.
al
Energy
Factor
or RE
Standby
Loss or
Pilot
Ext.
Tank
Insul. R-
Value
Status
Standard Gas 50 gal or Le
1
Small Gas
Kitchen Pipe Ins
40,000
50
0.58
Na
n/a
Existing
MULTI -FAMILY WATER
HEATING
DETAILS
HYDRONIC
HEATING SYSTEM
PIPING
Control
Hot Water Piping Length
ft
0
0
QPipe
—
System Name
Length
Pipe
Diameter
Insul.
Thick.
Qty. HP
Plenum Outside Buried
13
El
Energ Pro 5.1 by Energ Soft User Number: 5553
RunCode: 2013-0418710:58:53 ID: 2013 -GLS -13
Pa e 8 of 11
MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R
Project Name
ALBINGER"s Residence
Date
1411812013
NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of
the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF -
1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated
into the permit documents, and the applicable features shall be considered by all parties as minimum component performance
specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R
Form with plans.
Building Envelope Measures:
116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage.
§116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain
Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a).
117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed.
118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form.
§118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the
installation of a Cool Roof is specified on the CF -1 R Form.
*§150(a): Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor.
150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value.
*§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor.
*§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor.
150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95 2000 when specified on the CF -1 R Form.
150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
§150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance
rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration.
Fireplaces, Decorative Gas Appliances and Gas Log Measures:
150 e 1 A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox.
§150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is
equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device.
§150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the
outside of the building, are prohibited.
Space Conditioning, Water Heating and Plumbing System Measures:
§110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy
Commission.
§113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release
valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5.
§115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances
(appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and
spa heaters.
150(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA.
150(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c).
§150(j)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped
with insulation having an installed thermal resistance of R-12 or greater.
§1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water
tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the
tank.
§1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of
recirculating sections of hot water pipes are insulated per Standards Table 150-B.
§1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot
water tank shall be insulated to Table 150-B and Equation 150-A.
§1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table
123-A.
150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
§1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in
conditioned space.
150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation.
EnergyPro 5.1 by EnergySoft User Number., 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13 Page 9 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 MF -1 R
Project Name
Date
ALBINGER"s Residence
1411812013
§150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections
601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-
4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the
applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is
used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used
§150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed
sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may
contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area
of the ducts.
§150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands.
150(m)7: Exhaust fans stems have back draft or automatic dampers.
§150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers.
§150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar
radiation that can cause degradation of the material.
150 m 10: Flexible ducts cannot have porous inner cores.
§150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air
Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation
required in Section 4 of that Standard.
Pool and Spa Heating Systems and Equipment Measures:
§114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency
Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and
shall not use electric resistance heating ora pilot light.
§114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction
and return lines, or built-up connections for future solar heating.
114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover.
§114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or
programmed to run only during off-peak electric demand periods.
150 : Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150
Residential Lighting Measures:
§150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies
contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2.
150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d).
§150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than
20 kHz.
§150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain
only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line -
voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a
medium screw -base socket.
150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k).
150(k)7: All switching devices and controls shall meet the requirements of §150(k)7.
§150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be
exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant
sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed
luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a
manual -on occupant sensor.
§150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of
illuminated cabinet.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 ID: 2013 -GLS -13 Page 10 of 11
MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R
Project Name
Date
ALBINGER"s Residence
1411812013
§150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms
shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on
occupant sensor certified to comply with the applicable requirements of §119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a
manual -on occupancy sensor.
§150(k)11: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms,
closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be
allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual -
on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less
than 1000 square feet located on a residential site is not required to comply with §150 k 11.
§150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters
Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air
leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between
the luminaire housing and ceiling.
§150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more
dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the
same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that
they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor,
and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an
astronomical time clock not having an override or'bypass switch that disables the astronomical time clock; OR an energy management
control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor
luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion
sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed
luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not
be high efficacy luminaires.
§150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no
more than five watts of power as determined according to §130(d).
§150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable
requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable
requirements of Sections 130, 131, 134, and 146.
§150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more
dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided
that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119.
EnergyPro 5.1 by EnergySoft User Number: 5553 RunCode: 2013-04-18T10:58:53 /D: 2013 -GLS -13 Page 11 of 11