06-1436 (SOTB)P.O. BOX 1504
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
T -4b -t 4 4 Q"
Application Number: P-00001436
Property Address: 81450 CARBONERAS
APN: 764-200-006-37 -316811-
Application description: STRUCTURES OTHER THAN BUILDINGS
Property Zoning: LOW DENSITY RESIDENTIAL
Application valuation: 1500
Applicant: Architect or Engineer:
LICENSED CONTRACTOR'S DECLARATION
BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with
Section 70001 of Division 3 of the Business a rofessionals Code, and my License is in full force and effect.
LicenseClass:
C8 C27 C29 License No.: 656128
Date: 916� ontractor:� -
O NER-BUILDER DECLARATION
1 hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
1 _ 1 1, as owner *of the property, am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with a contractors) licensed
pursuant to the Contractors' State License Law.).
(_ 1 I am exempt under Sec. , B.&P.C. for this reason
Date:
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name: _
Lender's Address:
LQPERMIT
Owner:
GSAND
81-450 CARBONERAS
LA QUINTA, CA 92253
Contractor:
CALIFORNIA POOLS & SPAS
P.O. BOX 1280
COACHELLA, CA 9-)236
(760)398-9222
Lic. No.: 656128
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 4/10/06
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier SEABRIGHT Policy Number BB1060510
I certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any manner so as to become subject to the workers' compensation laws of California,
and agree that, if I should be oma subject to the workers' compensation provisions of Section
—` 3700 of the Labor Code, I hwith comply with those provisions.
Date: APplican[:/
WARNING: FAILURE TO SECURE WORKERS' OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject
permit to cancellation.
I certify that I have read this application and state that the above information is correct. I agree to comply with all
city and county ordinances and state laws relating to building co ction, and hereby authorize representatives
of this county to enter upon the above-mentioned grope y i,(peuyn purposes.
Date:nature (Applicant or Agent):
Application Number . . . 06-00001436
Permit . . .
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
35.00
Plan Check
Fee
22.75
Issue Date
Valuation
. .
1500
Expiration Date..
10/07/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
10.00 2.0000
HND BLDG 501-2,000
20.00
-------------------------------------------------
Special Notes and Comments
---------------------------
FIREPIT ANZI Z2231.
--------------------------------------'--------------------------------------
Other Fees
ENERGY
REVIEW FEE
2.28
Fee summary Charged
---------------------------
Paid
--------
- Credited
----------------------
Due
Permit Fee Total
35.00
.00
.00
35.00
Plan Check Total .
22.75
.00
.00
22.75
Other Fee Total
2.28
.00
.00
2.28
Grand Total
60.03
.00
.00
60.03
LQPERMIT
i
2—
Bin# - City of. La Quanta
La
Building U Safety Division
Permit # P.O. Box 1504, 78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-7012
0 �'`�,3 Building Permit Application and Tracking Sheet
Plan Sets
Project Address. - Cps �� e yS
C� Owner's Name: 7
Plan.Check submitted Item Amount
A. P. Number:
Address:
Legal Description:
City, ST, Zip: • /�
Contractor
Address- Z �j
Telephone:
Project Description:
q
City, ST, Zip C l ZZ�J
1 A
- Q. T Q [ �
Energy Calcs.
Telephone: %� 3�f I Zz �--
Plans picked up Construction berr g
State Lic. #: j2
City Lica#:
Arch., Engr., Designer:
Grading. plan'
Address:
god Review, ready for corrections/issue Electrical Q
City, ST, Zip:
Subcon tactor List
Telephone:
Called Contact Person Plumbing
Construction Type: Occupancy:
State Lie. #:
Project type (circle one): 6rml Add'n Alter Repair Demo
Name of Contact Person:
Sq. Ft.:
# Stories:
# Units:
Telephone # of Contact Person: pZSQ— C� C� �jl
Estimated Value of Project: 1 O
APPLICANT: DO NOT WRITE BELOW THIS LINE
#
Submittal
ReQ1d
Recd
TRAC]MG PERMIT FEES
Plan Sets
Plan.Check submitted Item Amount
Structural Calcs.
Reviewed; ready for corrections Plan Check Deposit
Truss Calcs.Called
Contact Person Plan Check Balance
Energy Calcs.
Plans picked up Construction berr g
Flood plain plan
Plans resubmitted Mechanical
Grading. plan'
god Review, ready for corrections/issue Electrical Q
Subcon tactor List
Called Contact Person Plumbing
Grant Deed
Plans picked up S.M.I.
H.O.A. Approval
Plans resubmitted Grading
IN HOUSE:-
''d Review, ready for correctionslissue Developer Impact Fee
Planning Approval
Called Contact Person A.I.P.P.
Pub. Wks. Appr
Date of permit issue
School Fees
Total Permit Fees
1�7 :'- 1 11
GRAND EFFECTS
Model 100=A
OWNER'S MANUAL /.
OPE RATI-NG AND M-AINT-E N -A -N -C -E - INSTRUCT -1 -OHS
For your safety:
If you smell gas:
1. Shut off gas to the appliance
2. Extinguish any open flame
near unit.
3. If odor continues, immediately
call your gas supplier
K (9 FF,(Ce .4
For your..safety:
Do not store or use any gasoline or
other flammable vapors and / or
liquids in the vicinity of this or any
other. appliance.
This manual should remain with the homeowner or parties responsible for operation
1l. 41
y
Table of Contents
Gas and Electrical Requirements
Page 3
Installation
Page 3
Insert'
Page 3.
Bowl Torch Assembly
Page 4
Burner Setup and Adjustment
Page 5
Maintenance
Page 7
Operation
Page 8
Spare Parts .
Page 9
Control Panel Wiring Diagram
Page 10
B'urrier Assembly Wiring Diagram
Page 11
1.0 Gas and Electrical reauirements:
1.1 Input Voltage: 120 Vac / 60 Hz to Grand Effects Control Panel
1.2 Gas type: Natural Gas
1.3 Gas Pressure: Nominal: 7" we
Maximum: 14" we
Note: If pressure is greater that 14" wc, a gas regulator will be required for this system.
1.4 Gas flow: 1 Burner System: 80 cfh
Note: Check with your gas supplier to verify gas flows and pressures available at the location
of your installation. In many cases utility companies will install larger meters at no charge to .
accommodate larger.flows.
2.0 Installation for Insert
Warning: This unit is for outdoor use only
2.1 Do not install near any combustibles such as wood structures, fuels, clothing, fabrics
or dry vegetation.
2.2 Never use any fuel other than natural gas.
2.3 Install Bowl Torch well out of the way of pedestrian. traffic.
2.4 Installation shall be performed by a licensed contractor. All aspects of installation
must conform to local codes, or in the absence of codes, with National Fuel Gas Cod e•
ANZI 2223.1.
2.5 The Control Panel shall be located where it can be easily accessible so that the gas
can be shut off quickly in case of an emergency. An approved gas valve shall bei
installed upstream of the unit and located in an accessible area. (The Control Panel
should not be hooked up to a remote means of operation, such as a Jandy Unit. All
operations, should be done at the Grand Effects Control Panel).
2.6 Install the Control Panel and gas piping as shown in Figure 1.
2.7 Low voltage 14 or 16ga wiring (24Vac) shall be installed underground between the
Control Panel and the Burner Assembly.
2.8 Maintain good piping practice by keeping pipe length and elbows to a minimum to
eliminate unnecessary pressure drops. (Do not use any flexible gas line)
2.9 Adjust the height of the insert as shown in Fig. 2. Cut off excessive length of bolts..,
rd
CONTROL PANEL
1 20VAC 60HZ INPUT-
(MOUNTED TYPICALLY
TO CONTROL PANEL
WITH POOL EQUIPMENT)
II
II
II
' I I
I I
II
II
IL I - --
- - -
� - - - - - - _
'
24VAC OUTPUT & 'CONDUIT (UNDERGRO'U'ND).
IL
-------------
L_ - - -
- - - - - - - - - -
3/4" GAS PIPING (UNDERGROUND)
Figure 1
REMOVE EXCESS
THREADED ROD
• AFTER INSTALLING NUT
1/2" BALL VALVE
' �
- -
II
[SUPPORT
n
II
2"
FIRE PIT
WALL
-
GRD.
+
NA
8" lMIN.
1
TO GRAND EFFECTS
REDUCE TO 1/2"
CONTROL PANEL
3/4" GAS PIPING
Figure 2
rd
3.0 Install Burner Assembly as shown in Figure 3. The Burner Assembly shall be centered.
and supported by the "SUPPORT".
3.1 Connect Gas Hose to Burner Assembly as shown in Figure 3.
3.2 Install wire nuts on wires from Control Panel and Burner Assembly. Be careful to hook
up the "positive" to the red wire and the "negative" to the white wire. Wrap wire nuts
with electrical tape or some means to prevent moisture from getting in.
3.3.1 With all gas connections tight, position Burner Assembly so that it sits level on the
"SUPPORT".
Figure 3
4.0 Installation for Bowl Torch
Warning: This unit is for outdoor use only
4.1 Do not install near any combustibles such as wood structures,. fuels, clothing, fabrics
or dry vegation.
4.2 Never use any fuel other than natural gas
4.3 Install Bowl Torch well out of the way of pedestrian traffic
4.4 Installation shall be performed by a licensed contractor. All aspects of installation
must conform to local codes, or in the absence of codes, with National Fuel Gas Code
ANZI AZ223.1
5
4.5
4.6
4.7
The Control Panel shall be located where it can be easily accessible so that the gas
can be shut off quickly in case of an emergency. An approved gas valve shall be
installed upstream of the unit and located in an accessible area.
Install the Control Panel and gas piping as shown in Figure 1.
Low voltage 14 or 16ga wiring (24 vac) shall be installed underground between the
Control Panel and the Bowl Torch.
Maintain good. piping practice by keeping pipe length and elbows to a minimum to
eliminate unnecessary pressure drops.
Install Bowl Torch Assembly as shown in Figure 4. (Gas piping and Electrical must be
centered with the hole in the bottom of the Bowl Torch).
MMENDED,.
Figure 4
5.0 Burner Setup and Adiustment
5.1 Setup:
5.2 On the Burner Assembly, check the spark electrode gap located on the pilot. It should
be adjusted to 3/16" as shown in Figure 5.
�{ 3/16" `
f
Figure 5
5.3.1 With the upstream gas valve in the "closed" position and 120Vac coming into the
Control Panel, turn the switch located in the panel to the "Orr"position. -i s
6
5.41 At the Burner Assembly, check that the spark electrode is arcing across the gap. You
should be able to hear and see the electrode spark. If there is no spark, adjust gap .
and orientation as shown in Figure 5.
5.5.1 Open the upstream gas valve.
5.6.1 In the Control Panel, turn the switch to the "On" position.
Note: At this time the Burner Assembly should ignite.* ,
If it does not light, it may be a result of air in the gas line.
Purging the air from the gas line may be required.
5.6.2 After the "Burner Assembly" has been lit, it can now be adjusted for flame size.
PILOT SOLENOID
JVI\L .I11 J
HONEYWELL FLAME SAFETY
Figure 6
(View is from bottom side of assembly)
VA
5.7 Burner Adiustment
Important:
Before you can adjust the flame size, you will need
to shut the Burner "Off' at the Control Panel and
let the Burner Assembly cool down..
5.7.1 The height of the flame can be adjusted by opening or closing: the ball valve as shown
in Figure 3 & 4. O
6.0 Maintenance
6.1 Periodically clean the Burner Assembly with a wet cloth or cleaning solution to remove
carbon build-up.
6.2.1 Frequency of the cleaning will depend on usage.
6.2.2 Periodically inspect the underside of the Burner Assembly for any signs of excessive
temperatures.
6.2.3 Check that all gas connections are tight.
6:2.4 If there are long periods of non use, the units should be covered or removed for .
storage. Gas should be securely shut-off during non use.
Note: If any problems are present, consult a licensed heating
specialist or call Grand Effects.
7.0 Operation
Warning: This unit is for outdoor use only
For your safety:
1. If you smell gas, shut off Gas Valve immediately.
2. Extinguish any open flame.
3. If odor continues, immediately call your gas supplier.
4. Do not store or use gasoline or other flammable vapors and / or liquids in the
vicinity of this appliance.
5. Do not leave flame on while unsupervised. .
6. Do not operate in windy or rainy conditions. If this is done;-uriit'will cycle on and off
automatically.
7. Unit should be operated only by a responsible adult.
8. When in use, an open flame is present, therefore, use with extreme care and at
your own risk.
9. Before any inspection of the unit, always turn off power and gas supply at the
Control Panel.
10. If you experience problems with this unit, call Grand Effects ora licensed hewing`
professional. All work on this unit shall be performed by a licensed heating
professional.
Caution! Before you turn on the Grand Effects System, make sure that it is clear or
people, animals or any objects that are combustible.
Oaeratina Instructions:
To turn unit "On":
1. Turn Burner Switch"On".
To turn unit "Off':
1. Turn Burner Switch "Off'.
:4.
Note: If Burner fails to light, turn corresponding Burner Switch
in the Control Panel to the "Off' position then to the "On"
position. This will initiate a new trial for ignition.
8.0 Spare Parts "
1/4" Pilot Solenoid
3/8" Main.Solenoid
Ignition Module
9
Grand Effects
1 year limited warranty
Grand Effects will replace, at its expense, any unit, which in normal use, has
proven to be defective in workmanship or material., provided that the customer
returns the product prepaid to Grand Effects with proof of product within one year
and provides Grand Effects with reasonable opportunity to verify the alleged defect
by inspection. Grand Effects will not be responsible for any asserted defect, which
has resulted from misuse, abuse, repair or alteration. Under no circumstances will
Grand Effects be liable for incidental or consequential damage r-es-ufting from
defective products. This warranty is Grand Effects' sole warranty and sets forth the
customer's exclusive remedy, with respect to defective products, all other
warranties, expressed or implied, whether of merchantability, fitness for purpose or
otherwise, are expressly disclaimed by Grand Effects. Grand Effects is not
responsible for any injury' or mishap related to misuse, abuse or lack of judgment
choosing fire display locations.
Contact us at:
GRAND EFFECTS
Office(949) 697-5270
Fax (949) 625-8027
e-mail: info@grandeffectsinc.com
12