Loading...
04-8264 (SFD)ri P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T4hf, (P " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 6/03/05 Application Number: 04-00008264 Owner: Property Address: 81490 CARBONERAS CORAL OPTION I APN: 764-200-006-33 -316811- 79285 RANCHO LA QUINTA DR Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253 6 Property Zoning: LOW DENSITY RESIDENTIAL D Application valuation: 309222 t' 1 Contractor: JUN Q 2005 Applicant: Architect or Engineer: ` SPARKS CONSTRUCTION, IN UP QUINTA LA QUBNTAOX 1716 CA 92247 CITY FINANCE0 PT• (760) 771-1941 Lic. No.: 674074 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 Icommencing with Section 7000) of Division 3 of the Busines d Professionals Co nd my License is in full force and effect. License Cla$s: B . i1 Li se o.: 674074 OWNER -BUILDER DECLARATION ' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 00003482004 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3 0 of the abor Code for ' h comp) those provisions. $at�W 0 Q pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERA EIS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION,�DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county or inances and state laws relating to building construction, and ereby authorize representatives of this cou to mer upon the above-mentioned property f pection p s s. HateQ nature (Applicant or Agent): l� C Application Number . . . . . 04-00008264 Structure Information Construction Type . . . . . TYPE V - NON RATED Occupancy Type . . . . . . DWELLG/LODGING/CONG <=10 Flood Zone . . . . . NON -AO FLOOD ZONE Other struct info . . . . . CODE EDITION 2001 CBC # BEDROOMS 4.00 FIRE SPRINKLERS NO GARAGE SQ FTG 752.00 PATIO SQ FTG 599.00 NUMBER OF UNITS 1.00 1ST FLOOR SQUARE FOOTAGE 3546.00 ---------------------------------------------------------------------------- Permit . . Additional desc . Permit Fee . . . Issue Date . . . Expiration Date . BUILDING PERMIT 1374.50 Plan Check Fee ... 223.36 Valuation . . . . 309222 6/03/05 Qty Unit Charge Per Extension BASE FEE 639.50 210.00 ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 735.00 Permit . . . MECHANICAL Additional desc . Permit Fee . . . . 101.50 Plan Check Fee 6.35 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 3.00 9.0000 EA MECH FURNACE <=100K 27.00 3.00 9.0000 EA MECH B/C <=3HP/100K BTU 27.00 4.00 6.5000 EA MECH VENT FAN 26.00 1.00 ---------------------------------------------------------------------------- 6.5000 EA MECH EXHAUST HOOD 6.50 Permit . . . .. . ELEC-NEW RESIDENTIAL Additional desc . . Permit Fee . . . . 154.15 Plan Check Fee 9.64 Issue Date . . . . Valuation 0 Expiration Date 6/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 3546.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 124.11 LQPERMI'f ,�. Application Number . . . . . 04-00008264 Permit . . . . . . ELEC-NEW RESIDENTIAL Qty Unit Charge Per Extension 752.00 .0200 -----------------------7---------------------------------------------------- ELEC GARAGE OR NON-RESIDENTIAL 15.04 Permit PLUMBING Additional desc . . Permit Fee . . . . 200.25 Plan Check Fee 12.52 Issue Date. Valuation . . . . 0 Expiration Date 6/03/05 Qty Unit Charge 'Per Extension BASE FEE 15.00 20.00 6.0000 EA PLB FIXTURE 120.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00, 11.00 .7500 EA PLB GAS PIPE >=5 8.25 1.00 15.0000 ---------------7------------------------------------------------------------ EA PLB GAS METER 15.00 Permit . . . GRADING PERMIT Additional desc . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 6/03/05 Qty Unit Charge Per Extension BASE FEE 15.00 ---------------------------------------------------------------------------- Special Notes and Comments SFD - LOT 33, PLAN 3A, 3546 SF. PERMIT DOES NOT INCLUDE POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 75% REDUCTION TO PLAN CHECK FEE DUE TO MULTIPLE ISSUANCE OF SAME PLAN TYPE ---------------------------------------------------------------------------•- Other Fees . . . . . . . . . ART IN PUBLIC PLACES -RES 273.05 DIF COMMUNITY CENTERS -RES 97.00 DIF CIVIC CENTER - RES 366.00 ENERGY REVIEW FEE 22.34 DIF FIRE PROTECTION -RES 97.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 225.00 DIF PARK MAINT FAC - RES 5.00 DIF PARKS/REC - RES 502.00 LQPERMIT LQPERMIT h,P-v"`T-Oib-2005 07:33 AM I NLANDi I NSPECT I ON. E . R. HS 951 8179043 INLAND INSPECTIONS 8c CONSULTING 7338 Sycamore Canyon Blvd, Suite 4 * Riverside, CA 92508 (951) 697-4000 * FAX (951) 697-1030 ULTRASONIC TESTING REPORT CLIENT: Eat Systems DATV: 11.22-08 JOB NO.: D !0 C �Dw INVOICE NO.: REPORT NO.: Revlew*d by: PROJECT: Andakwis LOT# 38 FABRICATOR: POW - J CODE: AWS D1.1 TECHNICIAN: Wade Clark ASNT LEVEL, 11 WELDING PROCESS: FLAW SURFACE: As Welded EPUIPMENT: Epoch 118 PROBES: 11 NORMAL PQ ANGLE Pq NIGH ENERGY (1 NORM ENERGY CALIBRATION: (X1 SOUND PATH 0 PROJECTED DISTANCE COUPLANT: (1 OIL [I GREASE (7Q PASTE 1) GLYCERINE 11 OTHER: P.05 � • • _ n � L . �� i{ . i � ry y r - 1 tt rt r. n n • r _ rt � _ • � �r rr ©rm�r[�rrrr�[�E� rrr�r�rrr�r�� ir■rrrrrrrrrrrrrrrrrrrr r�rr�■rirrrrrr�r�rrrr■r�r�■■ � �r�rrrrrrrrrrrrrr�wrr rr r ■rr■rrrrrrrrrr�rrrirrr�rr ��rr�rrrr■■rrrrirrirrirri rr rr �rrrrrrrrrr■rrrrrr■rrr�rr� rr��rrrr�rrrrrr�rrrrrrrrr .r rrrrrrrr■rrrrr�■rirrr■rr �r rrrrr■�■rr�rrrrrrr�rrrr�rr■r rr rr rr�rrr■rrrrrrrrNrrrrir■�r rrrrrrr�r■rrr�■r�rrrr�rr rr rrrri■rrrirr■�r■�r■■��rr�r rr r�rrr�rrrrrrrr�■■■r■�■rrrr■r SIGNATUFM ;�7�� d, LIJ 06/21/2006 13:52 17603471841 PARGON SCHMID PAGE 19 INSULATION CERTIFICATE This is to certify that insulation has been installed in conformance with the current energy regulation, California Administrative Code, Title 24, State of California, in the building at 81-490 CARBONERAS, LOT 33, -PHASE 1, SPARKS LA QUINTA, CA CEILINGS: - —' TYPE: BATTS MANUFACTURER: Certainteed THICKNESS: R-30 WALLS: TYPE: BAT`tS MANUFACTURER: Certainted THICKNESS: R-21 GENERAL CONTRACTOR: SPARKS CONSTRUCTION LICENSE # BY: TITLE: PARAGO SCHMID BUILDING PRODUCTS A MASCO Company LICENSE # 221517 BY. TITLE: ACCOUNT REPRESENTIVE DATE: q�1%