04-8383 (SFD)d
o
fl �ft�
7005
BUILDING' & SAFETY DEPARTMENT'
4 (760).777-701.2
�OF 9 .._c�1Np1✓ALLE AMPICO FAX (760) 777-7011
LA QUINTA,, CALIFORNIA 92253 INSPECTION REQUESTS (760) 777-7.153
BUILDING PERMIT
Application Number 0-4=0-0 0 0 83 8-3j Date 4/12,%05
Property Address . . . . . . 8,1635 CHARISMATIC WY
APN: 767-200-999-50 -312021-
Application description . DWELLING - SINGLE FAMILY DETACHED
Property Zoning LOW DENSITY RESIDENTIAL
Application valuation . . . . 1658,60
Owner
Contractor
DESERT CHEYENNE, INC.
HERINGTON DEVELOPMENT, JAMES 0
78401 HIGHWAY 11.1, SUITE G 40960 CALIFORNIA
OAKS RD, #283
LA QUINTA CA 92253 MURRIETA
CA 9-2562
(760) 777-9920
(951) 677-8415
WCC: STATE FUND
WC: 1542746
11/0.1/05
CSLB: 753190.
04/30./06
CCC: B
--------------------------
Structure Information --*-=---------------------
Construction Type .. .
. . . TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/LONG <=10
Flood Zone . . . . .
. . . NON -AO FLOOD ZONE
Other struct info . .
. . . CODE EDITION
2001 CBC
#BEDROOMS
4.00
FIRE SPRINKLERS
NO
GARAGR SQ FTG
658.00
PATIO SQ FTG
319.00
NUMBER OF UNITS
1.00
1ST FLOOR SQUARE FOOTAGE
.2600.0.0
Permit . . . . . . BUILDING PERMIT
Additional desc .
Permit Fee . . . .
870.5'0 Plan Check Fee
14.1.46
Issue Date . . . .
Valuation . .
165860
Qty Unit Charge
Per.
Extension
'BAS'E FEE
639.50
66.00 3.5000
THOU BLDG 100,0.01=500,000
231.00
Permit . . . . . . MECHANICAL
Additional d'esc . .
Permit Fee . . . .
90.00 Plan Check Fee
5.6.3
Issue Date . . . .
Valuation . .
. . 0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
;2.00 9.00.0.0
EA MECH FURNACE <,=.100K
18.00
2.00 9.00.00
EA MECH B/C <=3HP/100K BTU
5..00 6.5000
EA MECH VENT FAN
32.50
I\
P.O. BOX 1504 • VOICE (760) 777-7012
78-495 CALLE TA'MPICO FAX (760) 777•-7011
LA QUINTA, CALIFORNIA 92253 INSPECTIONS (760) 777-7153
BUILDING & SAFETY DEPARTMENT '
Application Number: ori - 5383 . Date:— Y-119-0
Applicant:
Applicant's Mailing Address:
I hereby affirm under penalty of perjury that I am
Ce,_and.my License is in II force and effect.
i,.,cense. Class
c
�15ate � � � �`- ntractor
Architect oar Egineer `
chitect or Engineer's, Address:
No. J ?
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
under provisions of Chapter 9 (commencing_ with Section 7000) of Division 3 of the Business and Professionals
i5rise No. ��� J D
(7 OWNER43UILDER DECLARATION
I hereby affirm under penalty of perjury that am exempt from the Contractors' State License Law for ".following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit,to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file waigned
statement that hwor she is.licensed pursuant to the provisions of the Contractors' State:License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and"Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five" hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as theirsole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions.Code: The Contractors' State License Law does not applyto'an ownerof property who builds or improves thereon, and who does the work
himself or herself'or through his" or her own employees, provided that the improvements are not intended or offered for sale. IL however; the building or'improvement is
sold within one year of.comple{ion, the,owner-builder will have the burden of proving that he or she did not build:or improve for the purposeof sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State LicenseLaw does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to
the Contractors' -State License Law.).
U Lam exempt,under Sec. , BA P.C..for this reason
Date Owner
WORKERS' COMPENSATION DECLARATION
I, hereby affirm under penalty of perjury one of the following "declarations:
I have and will maintairva certificate of consent 'to self-insure"for workers" compensation, as provided for by Section 37001 of the, Labor Code, for "the -performance
_of the work,for which this permit is issued,
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
[� tseabd. �Atr work�e compensation msme carrier and �ofr urt�erre:
artier J �'����: /'r/.. �I iP61ey umber /
I certify that, in the performance of the work r whA this employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agre th , i I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, l shall
forthwith comply"with those provisions.
WARNING: FAILURE TO SECURE WORKERS' CO EASATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION. DAMAGES AS PROVIDED FOR IN
SECTION 3708 OF THE LABOR CODE, INTEREST, AND ATTORNEYS FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there,is a construction lending agency for the performance of the work for which this permit is issued (Sec: 3097; Civ. C.),.
Lenders Name
Lender's Address IV
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the: Director of Building and Safety for a permit subject to the conditions,and restrictions set forth an this application.
1. Each person upon whose:behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and holdharmless the City of La Quinla, its
officers, agents and employees for -any act or omission related to the work being performed under or following issuance'of this permit.
2. Any permit issued as a result of this application becomes ull and void if work is not commenced within 180 days. from date of issuance of such permit, or
cessation:of work for 180 days will subject permit to canoe do
I certify that.l have read this application and state that the above info ti 1 correct. I agree to comply with alLcity and countyordinances;and state laws relating to building
construction, and herebyauthonze,re sentatives of this county to en po the above-mentioned property for inspection purposes.
�XDal"'
e Signature, (Applicant or Agent):
J
Application Number
04-00008.383
Page 2
Date 4/12/05
Qty Unit Charge
Per
Extension
1.00 6.5000
EA MECH'EXHAUST HOOD
6.50
Permit . .. . ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
119.16 Plan Check Fee
7.45
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge
Per
Extension
BASE FEE
15. GO
2 6,0'0 . 0 0 .0350
ELEC NEW RES - 1 OR 2• FAMILY
91. 0.0
6.58.00 .0200
ELEC GARAGE OR NON-RESIDENTIAL
13.16
Permit . . . . . . PLUMBING
Additional desc .
Permit Fee . . . .
166.5.0 Plan Check Fee
10.4.1
Issue Date . . . .
Valuation . . . .
0.
Qty Unit Charge
Per
Extension
BASE FEE
15.00.
16.00 6.0000
EA PLB FIXTURE
96.00.
1.00 15.00.00
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
8.00 .7500
EA PLB GAS PIPE >=5
6.00
1.00 15.0000
EA PLB GAS METER
1.5.00
------------------------------------------------------------------------------------
Permit . . . . . . GRADING PERMIT
Additional desc . .
Permit Fee . . . .
1.5:00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Qty Unit Charge
Per
Extension
BASE FEE
15.00
Special Notes and Comments
SF.D - LOT 50, PLAN 2B,
2600 SF. PERMIT
DOES. NOT'INCLUDE POOL,
SPA, BLOCK WALLS,
OR DRIVEWAY APPROACH.
75% REDUCTION TO
PLAN CHECK FEE DUE TO
MULTIPLE ISSUANCE
OF SAME PLAN TYPE.
Other Fees . . . . .
. . . . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
97.00
1
Page 3
Application Number
.. . . . .
04-00008383 Date
4/12,/05
Other Fees . . .
. . . .. . .
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
14.15
DIF FIRE PROTECTION=RES
97.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF PARKS/REC - RES
502.00
STRONG MOTION (SMI) - RES
16.58
DIF .STREET MAINT FAC -RES
15.00
DIF TRANSPORTATION - RES
10.98.00
Fee summary
Charged
Paid Credited,
Due.
Permit Fee Total
1261.16
.00 .00
12'61.1.6
Plan Check Total
164.95
.00 .00
164.95
Other Fee Total
2435.73
.00 .00
24.35.73
Grand -Total
3861.84
.00 .00
386.1.84
lq/24/2995 69:43 951-686-8786
W-61
WESTERN INSULATION
CF6R INSULATION CERTIFICATE
PAGE 11/22
THIS IS TO CERTIFY'THAT INSULATION, HAS BEEN INSTALLED IN CONFORMANCE WITH
THE CURRENT ENERGY REGULATION, CALIFORNIA ADMINISTRATIVE CODE, TITL' E 24,.
STATE OF CALIFORNIA, IN THE BUILDING LOCATED AT:
TRACT/PHASE: RANCHO'SANTANA I PHASE 1
LOT 60.1,
SITE ADDRESS: 81-636 CHARISMATIC WAY LA QUINTA, .CA
-,-------------------------------
C,'
BLOWN INSULATION
MANUFACTURER: GREENFIBER THICKNESS: &1' R- VALUE: R-30
CEILINGS:
BATTS
MANUFACTURER: KNAUF
'THICKNESS: 10" R- VALUE: R40
>LilOR'WAUS:
BATTS
MANUFACTURER: KNAUF
THICKNESS: 3'Y7 R- VALUE: R 13
ENE CONTRACTOR:
DESSERT ELITE
BY:
TITLE:
DATE:
INSULATION CONTRACTOR_
WESTERN. INSULATION, L.P.
LICENSE NUMBER: 794484
BY:
TITLE:
DATE:
OCT -29-2008 1.0:13 PM - P.16
CERTIFICATE OF FIEX,D VER><FICATION AND DIA NOSTIC TEMNG -
CF -4R
1-1`016 Tit
-14
1i
df Builder Name
Bui er Telephone Plan Number
HERS FuerSOMPIS Group Q_nbir
Ce Slgnaturo�' ate Sample House Number
FIt HERS Provider, C Iy�El�s
Street Address Circ lfi ClWststm0p: /—a
Copies to: Builder, HERS Provider
HERS
The house was; ❑ Tested grApproved. as part of sample testing, butwas not tested
Asth HERS.rotor providin diagnostic testing and field verification, I certlly that the houses Identified on this form
COM with the dlegnostic eated compliance requirements as checked on this form.
Distribution system is fully ducted (i.e., does not use.bullding cavities as plenums or platform retums In lieu
ducts)
Where cloth backed, rubber adhesive dud tape is Installed, mastic and drowbands are used In combination
with doth backed, rubber adhesive. duct tape to seal looks at duct connections.
❑ MINIMUM REQUIREMENTS FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Testing Results (Maximum 0% Duct Leakage)
Measured
Duct Pressurization Test Results (CFM ® 26 Pa) values
Test Leakage Flow in CFM
If fan flow Is calculated as 400clim/ton x number of tons enter
calculated value hare
If Ten flow,le measured enter measured value here
Leakage Percentage (100 x Test Leakage/Fan Flow) a
Check Box for Pass or Fag (Pass:tf96 or lass)
0
ass Fail
THERMOSTATIC EXPANSION VALVE (TXV) or Commission approved eyuivslent
Yes ❑ No Thermostatic Expansion Valve (or Commission approved
equivalent) is Installed and Access IS proVided for inspection
Yes is a pass
C,a MINIMUM REQUIREMENTS FOR DUCT DesION COMPLIANCE CREDIT
Pass Fail
1. O Yes 0 No ACCA Manual D Design requirements have been met
11 A
(rater hoe verified that actual Installation matches values In
CF -1.R and design on plan. ✓ "
2. O Yes O No TXV Is installed or Fen flow has been verified. H no TXV,
verified fan flow matches design from CF -1 R.
Measured Fan Flow =
Yes for both 1 and 2 Is a Pass
Q D
Pass Feil
Oct 31 20015 8:49AM LDI MECHANICAL
(760)343-0892 p.23
DUCT LEAKAGE AND DESIGN DIAGNOSTICS
yul."r Als.rtr atenttl"Pit �l— (35 �'.�/a12i 5 /I%QTic W4 y
Prmwimtieo Tut Romlu (CYN 025 PA) Tat Lakop(CFIW-
Fao Flow
Irpo Plow b Caloabtad at 400 G&WOe x awnbar ed tom, w u 11.7 x Hft t<Qtped1Y
to Thousermis'Of ebu, ontw.cdpAdW value hero
IHan Row b meaeurW, enlermaew w ww,twe
Lech p Praodon - Tat Ladmp doUWW ar Cdalood fm Now) >y o
Pni i(lee>nlaSvodon <R06 Put Fan
o RorABROSOL TYPE SUL4NM ONLY The tollowl" dkpodk ws tag was coaapldo*
Duct ?a Pnourizolm atrough-in.meenued leairoge.(CPW
(HgpcAr=F1Ni WNO WALL,
O Ye: G No O Pjetue pea %n orHottea projwdudon tent
O Ya O No O Visual innmotion oaf Duct Com"doas o 0
Peer i+oll
n MM -
Zym O No ZltetttmdWo &tpaaeion Valve Is iaetelied aad Ataooss is • provided hr 6upoetion
Yea b a pas o
Pose rd
e DUCT Del -
ACCA hIM" D Dodge ante 1dWo hate bam
1. O Yes o No oompkw' DuctOeow Is an on plow OW om la mkftn
metw" Plans.
Z. O Ya O` No .=V G bWOod w iota lbw hU been va GI& uae.Zxv, o o
Paas
reaw fm Bow sutobw 4IWgri ttetn O4L .'all
Masurod Fan Flow
Yet Or boli I sari l le a Paas
O %gm mbwelpe4 v4' Bat the obove d ftmWo tat smhr aad do wodc i palbrteod modood adds da On*) bin omdkmmW
V46 60"gdmmso fcraompitoieewWL t2habu0der.did porido droKUS p orldwaaopy of *o OLdRdPW bpdaabaddar
tin ea orwlb. attso s ea dfYng diet diagaosdo tearing ad bolledaa neat tit m piron # hr iw4llmW M& )
l.. -Q - X MeC nrt�'cal
T" Dale lmftftg &ftw trww (Ca ill oW OR
Palbrmd Galeal Coatfaotor M& Natao)
oo'Y t� g�YMg Depn4geae
Hm Pt wft Of apollabte)
Be wbg omw u,omw nay
Comp lim Font» August= %-Z$
Certificate of Occupancy
Building & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 81-635 Charismatic Way
Use classification: Single Family Dwellings
Occupancy Group: R31U1
Owner'of Building: Desert Elite Inc
Building Official
Building Permit No.: 04-8383
Type of.Construction: VN Land Use Zone: RL
INA
Address: 78-401 Highway 111 Suite G
City; ST, ZIP: La Quinta, CA 92253:
By: Daniel P. Crawford Jr.
Date: 1/30/06
PLACE