05-5389 (SFD)P.O. BOX 1504 4
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
r BUILDING PERMIT
Application Number: .;0 sD�s!3R9� Owner:
Property Address: 77187 CASA DEL SOL JOSEPH BIRDSELL
APN: 773-360=016_- - - P.O. BOX 636
Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92247
Property Zoning: MEDIUM DENSITY RES
Application valuation: 2133.94
Applicant:
I hereby affirm under penalty of pe
Section 7000) of Division 3 of the
License Class: B
Architect or .Engineer:
Lic. No.: OOR SQUARE FOOT
-----------------------------
RACTOR'S DECLARATION
�derprovisions-ofChapter 9.(commencing with
ssio Is Code, and my License'la,in full force and effect.
nse No.: 8
A-BUILDERDECLARATION
I hereby affirm under'psnaity of perjury that I am bgempt from the Contractor's State License Law for the
following reason (Sec. 7031:5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permittto1ile a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
Ucense'Law (Chapter 9 (commencing with,Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by
any applicant for a permit subjects the applicant to a civil penalty�of-not more than five hundred dollars ($500)::
(_) I, as owner of the property, or my employeeswithwages as their sole compensation, will do the, work, and
the structure is not intended or offered for sale (Sec. -7044, Business and Professions, Code. The
Contractors' State License Law does nat'apply to an owner of property who builds or improves thereon,
and who does'the work himself or herself through his or her own employees, provided that the
improvements:are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the;owner-builder will have the°burden of proving that he or she did not build or
improve for the purpose of'sale.).
(_) I, as owner of the property, am exclusively contracting with licensed contractors to constructthe project (Sec.
44
70, Business.and Professions Code: The Contractors'' State License Law does not apply to an owner of
property who builds or improves thereon, and who contracts for the projects with,a centractorls) licensed
pursuantto,the Contractors' State License Law.).
(_) I am exempt under Sec. , B.&P.C. for this reason
Owner,
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of',the
work,for which this permit is issued (Sec. 3097,:Civ. C.),
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 2/03/06
LIJ
Contractor:
BIRDSELL BUI'LDERS INC IVI FEB (J 2006
P O BOX 63.0
LA QUINTA, CA 92247 �OFLAQUIBNTI
(760)409-7070 NCE DEd'T
Lic. No.: 862631
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty:of perjury one of the following declarations:
_ I have and will maintain a certificate of consent.to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the workfor which this permit is
issued.
_ I have and will maintain workers' compensation,insurance, assequired by Section 3700 of the Labor
Code, for the performance. of the work for which this permit is issued. My workers' compensation
Insurance carrierand policy numberare:
Carrier STATE FUND Policy Number 2292649105
_ 1 certify that, in the performance of the work for which this permit is issued, I shall not employ any
person in any mannerso as tfteco e . �toorkers' compensation laws of California,
and agree that; H I s Ide s' co nsation provisions of Section
= 7_QQ of the Labor I s al forth h ro ions.
WARNING: FAILURE TO SECURE WORWS' eOMPENSATION. COVERAGE41S UNLAWFUL, AR54HALL
SUBJECT AN EMPLOYER TO CRIMINAL..PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOblS,4kND
DOLLARS (8100,000). IN -ADDITION TO THE COST OF COMPENSATION, DAMAGES ASL PROVIDED R IN
SECTION 3705 01` THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions, and restrictions set forth on this application. -
1. Each person upon whose behalf this application ie made,:each person st whose request and for
whose ' benefit work is performed under or pursuant to:any permit issued as,a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quints, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as asesult of this application becomes null and void N work is not commenced
within 1 SO: days from date of issuance of such permit, or cessation of work for ISO days will subject
permit.to cancellation.
I certify that.I have read this application and state tit e a v 'nformation is correct. I tee to comply with all
city and county ordinanceslend state laws r ing,t��buiIdi ce coon, end hereby auth iZe representetivea
of this county t�f upon the above -me rode pr Poe
ins Ion purposes. \\
Application Number . . . . 05-00005389
L NwV I
Permit . . . BUI_LDING PERMIT
�r
Additional desc . .
Permit Fee
1038.50
Plan Check Fee
675.03
Issue Date . . .
Valuation . . . .
213394
a■
Expiration Date
8/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
639.50
114.00 3.5000
THOU BLDG
100,001-500,000
399.00
Permit . . . ELEC--NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
162.72
Plan Check Fee
40.68
.Issue Date
Valuation . . . .
0
Expiration Date
8/02/06
Qty Unit Charge
Per
BASE
FEE
Extension
15.00
32.49.00 .0350
ELEC
NEW RES - 1 OR 2 FAMILY113.72
950.00 .0200
ELEC
GARAGE OR NON-RESIDENTIAL
19.00
1.0.0 15.0000
EA ELEC
TEMPORARY POWER POLE
15.00
Permit . . . GRADING PERMIT
Additional desc . .
Permit Fee . . . .
15.00
Plan Check Fee
.00
Issue Date . . .
Valuation . . . .
0
Expiration Date
8/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
Permit .. . . MECHANICAL
Additional desc . .
Permit Fee . . . .
101.50
Plan Check Fee
25.38
Issue Date . . . .
Valuation . . . .
0
Expiration Date . .
8/02/06
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
3.00 9.0000
EA MECH
FURNACE <=100K
27.00
3.00 9.0000
EA MECH
B/C <=3HP/100K BTU
27.00
4.00 6.5000
EA MECH
VENT FAN
26.00
1.00 6.5000
---------------------------------------------------------------------------------
EA MECH
EXHAUST HOOD
6.5.0
L NwV I
Application Number . . . . . 05-00005389
Permit . . .
PLUMBING
t Additional desc . .
Permit Fee . . . .
184..50 Plan Check Fee
46.13
Issue Date . . .
'Valuation . . .
. 0
Expiration Date . .
8/02/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
19.00 6.0000
EA PLB FIXTURE
114.60
1.00 15.0.0.00
EA PLB BUILDING SEWER
15.00
1.00 7.50.00
EA PLB WATER HEATER/VENT
7.:50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0.00'0
EA PLB LAWN SPRINKLER SYSTEM
9.00
8.00 .7500
EA PLB GAS PIPE >=5
6.00
1. OD 15.0.000
EA PLB GAS METER
15..00
---------------------------------------------•-------------------------------
Special Notes and Comments
32.49 S.F. SFD `PERMIT
DOES NOT INCLUDE
BLOCK WALL, POOL/SPA
OR DRIVEWAY
APPROACH
---------------------------------
Other Fees . . .. . .
7 -------------------------------------------
. . . . ART IN PUBLIC PLACES -RES
33-.48
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
4.80.00
ENERGY REVIEW FEE
67.56
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CkECK FEE
15.00
DIF LIBRARIES -.RES
355..00
DIF PARK MAINT.FAC - RES
22.00
DIF PARKS•/REC - RES
892.00
STRONG MOTION (SMI.) - RES
21.33
DIF STREET MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1666.00
Fee summary Charged Paid Credited
Due.
--------- ----------
Permit Fee Total
---------- ---------- ----------
1502,.22 .00 .00
1502.22
Plan Check Total
787.22 250.00 .00
537.22
Other Fee Total
3833.31 .00 .00
3833.31
Grand Total
6122.75 250.00 .00
5872.75
UPoxea de cAoatnas
1340meownehs cAssociatioK
C!o Wd Coact Sufpusos. She.
January 26, 2006
Joseph Birdsell
P.O. Box 630
La Quinta, CA. 92247
Re: Construction — 77-187 Casa del Sol
Dear Mr. Birdsell:
As you already know at our recent Architectural Review Committee meeting, held on January 13, 2006,
the Board reviewed your plans and renderings for construction for the aforementioned address.
The committee required a few modifications be made to your submitted plans. These modifications were
completed and resubmitted, the architectural review committee met on January 23, 2006 and approval
was given for you to commence construction. You may use this letter, if you wish, for the City or any
banking or lending institutions as a formal approval of construction as submitted to the architectural
committee.
I would like to take this opportunity to congratulate you and wish you happiness and success on the
construction on your home. If there is anything the Board, architectural review committee or
management can do to assist you, please do not hesitate to call upon us.
Very Wdy yours,
For the Architechowl Review Committee
FLORES DE MONTANAS HOMEOWNERS ASSOCIATION
fs
Patryceftcondgilm6
Property Manager
Gold Coast Enterprises, Inc.
84-400(D*WCN CD". Suft ,- ♦ Ca"W Cay, U 922840 (760) 202.9880 *%, (760) 202.9260
lecording Requested By
,,�irst American Title Company
Riverside Resale
AND WHIN RHCOV= MAIL TO:
DOUGLAS D. BIRDSELL
P.D. Box 630
LA gUISTA, CA 92247
ESCROW.,
.00C N 2005-0373289
page 1 of f Oaa T Ter Pe/d
Recorded !n Offlolil RCCOrde
Cerner of tliverelde
(.e rr W. Yard
Ad®eesor, CerMy Clefk A Raaorder
r a N eau en • a Caen - Ioea!1 IIeC.
I
a aa. ►aro neluw le+le u+r
GRANT DEED r
I= LWOEIISMIM CW r0XM 0=AMW THAT 0WILUgOftAn UAN5 W TAX 18: COVNTr Sl&X
X) eotopaoed ot< ball Value of pr uopveyed, or
comprecd on fall Value tea v�1ae of Bans os em rubeslwliniv at tbeuof sale, SF
uranterpnr:,beAarru; (X ] (]ty of ,J.a Ouiela , s�
POR A VALUABLE CONSIDMT10N. Receipt of which is Aenby aclalowie4 w
Sabo T. F'i0an, an varttarrled Mn
1
bw4bY GUM(S) to DOUCLS D. BUDS=, A SUgle X=
r
a fa lbllowing dewdbed property is the 'C ty at L Qotata. C ity of Riverelde 5ple of QlffomW
WA I in Bleck SOS of Sap►a Canard at Vale La QWnta (halt No. 11, to the !61ty of La Quka. Gmaty of Rieeside,
ac per map mcorded to Sea 18, Pagebj 7S, of blaps l .tbe Ofte of the Copmy Raxwdw of =W County.
kga F. Eigg
Doc.== Date.• April la, 2=
STATE OP CALr Fnna"_,A >sa
COu1+Tr OF a _
Op A 4a,,t. _ 2 2 . 10-C1 'S _ beton ult.leaR]¢aWiQA Y Ia L.a , i I+ovry rMic,
ON Will knows towns (rr pn►"d m,= a Ihe'arlio of -20 1buy,evbeoa wboas Pon
lad **n0la1ellpd'10 =0 Od boAdd ty aeeeetad the am In bldbeWtbetra woorlted eapae
We PenMM of oa a+ub upon bebdrorvbkk ebe Oo r"Aw wide camudfle ilYllwrom.
wnnu my bold wo,owatal nw.
Wbeaa N=(41daR,S*Wy a Ibt p11tY11 'duallawau
� qed 16tt br bii1�ltbrir fyrWRW 'en Ibe oatnraeet
rids arca Iar g(raid Iiotr w Simi.
ulrrl ilonl�1a11 •�.an�M.rnQ1 1 IIIj
q
6p11
Mail Tax Sum= to: $AMIN AS ABOVE or A#km NOW &low
DeScrlPOOn:• Riverside, CA Documont-Year.Doc[D 2005:373269 Page: 7 of
Order, /so Comment -
TOTAL P.01
Certificate Of Occupancy
�
-
w�
OF 9 Building Y p & Safety Department
This Certificate is issued pursuant to the requirements of Section 109 of the California Building
Code, certifying that, at the time of issuance, this structure was in compliance with the
provisions of the Building Code and the various ordinances of the City regulating building
construction and/or use.
BUILDING ADDRESS: 77-187 CASA DEL SOL
Use classification: SINGLE FAMILY DWELLING Building Permit No.: 05-5389
Occupancy Group: R-3 Type of Construction: VN Land Use Zone: RM
Owner of Building: JOSEPH BIRDSELL Address: P.O. BOX 636
City, ST, ZIP: LA QUINTA, CA 92253
_ By KIRK KIRKLAND
a'
Date: DECEMBER 29, 2006
Building Official
POST IN A CONSPICUOUS PLACE
TITLE 24 REPORT
Title 24 Report for:
JOSEPH BIRDSELL
MAIN HOUSE
LA QUINTA, CA
Project Designer:
OWNER
MR. JOSEPH BIRDSELL
LA QUINTA, CA
Report Prepared By:
.ADRIANA GIL
Adriana Gil
74-854 Velie Way Ste. #8
Palm Desert, CA 92260
(760) 404-7917
Job Number: CITY OF LA QUINTA
ADY315-1105 BUILDING & SAFETY � PT'
AP P �� U: �i�ON
FOR CON
Date: 06 13 �1D
aA
1/10/2006 COPY
The EnergyProcomputer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft, LLC - www.energysoft.com.
EnergyPro 4.0 byEnergySoft Job Numbec,ADY315-1105 User Number: 5553
I TABLE OF CONTENTS I
Cover Page 1
Table of Contents 2
Form CF -1 R Certificate of Compliance 3
Form MF -1 R Mandatory Measures Summary 8
Form WS -SR Residential' Kitchen Lighting 10
HVAC System Heating -and Cooling Loads Summary 11
EnergyPro 4.0 by. EnergySoft Job Number: ADYMA 105 User.Number:.5553
Certificate Of Compliance : Residential (Part 1 of 3) Cf -1 R
JnSEPH RIRDSELL 1/10/2006
. Project Title Date
MAIN HOUSE I A QUINTA
Project Address Building Permit #
Adriana Gii (760 40) 4=7917
Documentation -Author Telephone Plan Check/Date
EneraVPro 15 Field Check/Date
Complilfice Method Climate Zone
Source Energy Use Standard Facing Facing Facing Facing
(I(Btulsf-yr)
Design
Space Heating
1.79
Space Cooling
59.83
Fans
9.00
Domestic Hot. Water
9:80
Pumps
0.00
South Mar in
1.70
0.10
51.78
8.05
9.04
-0.04
8'.88
0.92.
0.00
0.00
Totals 80.42 69.67 10.74 66.78 13.63 71.40 9..02 68.55 11.87
Percent better than Standard: 13.4% 17.0% 11.2% 14.8%
Building Type:
[ Single Family
❑ Addition
Total Conditioned Floor Area:
2,620 ft2
09-A3 ZO[IEUBdrs-
28-A4 Zone VIM --
'IBdrs_ROat'-Wood-
. ❑ Multi Family
❑ Existing + Add/Alt.
Existing, Floor Area:
n/a ft2
Building Front Orientation:
All Four Orientations
Raised Floor Area:
0 ft2
Fuel Type:
Natural Gas
Slab on Grade,Area:,
2,620 ft2.
Fenestration:
Average Ceiling Height:
11.5 ft
Area:
490 ft2
Avg. U: 0.34
Number of Dwelling Units:
1.00
Ratio:
18.7% Avg. SHGC: 0.28
Number of Stories:
1
BUILDING ZONE
INFORMATION
# of Thermostat
Vent
Zone Name
Floor Area Volume
Units Zone Type Type
Hgt. Area
FJ1/AC gpl stem
HVAC 5 Ip it SJstem
Zn 1
Zn II'
?T45 -16;7D4
1,167 13,426
_05� Conriitioned _ Setback
0.4� _ Snnditioned Setback
- _-n/a
2 n/a
OPAQUE SURFACES Insulation Act. Gains Condition
Type Frame Area U -Fac. Cay. Cont: Azm, Tilt Y / N Status JA IV Reference Location / Comments
Rnpf Wnnd 1 453 _n Q2,Q X38_ R-0 0 _q0_ 1g
Wall Wood 542 0.074 R_13. R-4-5 .90 _gip
Wall WOOd 492 0074. R_13 RAE 270--__90
Wall Wnnd 370 0-074 __$_1.3__R-4.5_ 0_:-911
Door N_ _one 21 _Q:50D �IoOe. �Q� Q_._9Il
Roof Wood-1 167 0.029 .--.R-38 R-0-0 _90.x.$
Wall Wood- 373 0.074 .-_R-13_ R-4 5_ 90 g0
Wall Wood- 345 0 074. _ R 3' _R-4 ri. -180
Wall Wnnd 185 0.074 R-13_ R-4.5. 270 _ 90
Wall Wood-_ 44 0,674 _- R-13 R-4.5 _90
X
§
X
®❑New
®
®
❑
❑
❑
❑
❑
F-1
F1
F
❑❑
F-1
❑❑
❑New
❑►slew
❑New-
❑New
[71New
❑'New
❑New_
❑'.
❑
❑.
❑
❑.
F7
71
❑
F1
02A111 Zone I Bdrs
09-A3 Zone I"Bdrs.
09-A3 Zone UiBdrs.
09-A3 ZO[IEUBdrs-
28-A4 Zone VIM --
'IBdrs_ROat'-Wood-
02-A11_ Znne II Common Areas,
09-A3 7nne II rnmmon Areas
New 09-A3 Zo_n -11-Cnmmnn Area-,
New 09-A3 Zone II Common Areas
09-A3 .7one'll Common Areas
-
-
-
EnergyPro 4.0 by Energypoft User Number. 5653 Job,Number: ADY315-1105 Page:3 of 12
Certificate Of Compliance Residential (Part 2 of 3) QF -IR
JOSEPH BIRDSELL 1/10/2006
-Project Title Date
FENESTRATION SURFACES
'True Cond. .Location/
-# Type Area U-Factorl SHGCZ Azm. Tilt Stat. Glazing Type Comments
.L
2,
Window
Window
'L'eft (East) 75A _D.340 NFRC _02B NFRC
Left (East) 5:0 0.340 NFRC 0.28 NFRC
_90- -991 New BETTER BUILT Vinyl low E_
90 90 New BETTER BUILT Vinyl low E
Zone I Bdrs.
Zone I Bdrs.
3
Window
Left East 5:0 0.340 NFRC 0.28 NFRC
90
90 New BETTER BUILT Vinyl low E
Zone,l Bdrs.
4
Window
Left East 25:0 0.340 .NFRC 0_28 NFRC
90
90 New BETTER BUILT Vinyl low E
Zone I Bdrs.
5
Window
Right 0.340 NFRC 0_28 NFRC
270
90 New BETTER BUILT Vinyl low E
Zoned Bdrs.
6
Window
Right (West) 12:00340 NFRC 0. 8 NFRC
270.
90 New BETTER BUILT Vinyl low E
Zone l Bdrs.
7-
8
Window
Window
Right West) 12.0 0.340 NFRC 0.28 NFRC
Right (West) 15.0 0.340 NFRC 0.28 NFRC
270
270
90_ New _BETTER BUILT Vinyl low E
90 New BETTER BUILT Vinyl low E
Zone l Bstrs.
Zone.I Bdrs.
6
Window
_0.340 NERC 0.28 NFRC
270
90 New BETTER BUILTVinyl�w E
_Zone I Bdrs.
A
-WindD r�Right
(Lest) 15.0 _Q,3AO NERC -0-.28 NFRC
270
90 Now BETTER BUILT Vinyl low E_
2one I Bdrs.
11
Window
Right (West) 6:0 0_340 NFRC 0.28 NFRC
270
90 New BETTER BUILT Vinyl low E
Zone I Bdrs.
12
Window
Left (East) 4.0 0.340 NFRC, 0_28 NFRC
90
90 New BETTER BUILT Vinyl low E
Zone II Common Areas
_Ja
14
Window L eft (East) 4.0_ _0.349 _NERC 0.28 _NFRC
Window Left (East) 4.0 0.340 _NFRC 0.28 NFRC
90.
90
_211 New BETTER BUILTVinyl IQw_E_
90 New BETTER BUILT Vinyl low E
Zone II Common-Amas_
Zone 11 Common.Areas
15
Window
Left (East) 4A. 0.340 NFRC 0.28 NFRC
90
90 New BETTER BUILT Vinyl low E
Zone II Common Areas
16
Window
Rear (South) 1'5:0 0.340 NFRC 0:28 NFRC
180
90 New BETTER BUILT Vinyl low E
Zone 11 Common Areas
17
18
Window
Window
Rear (South) 42.6 0.340 NFRC 0_28 _NERC
Rear (South) 1510 0.340 NFRC 0_28 NFRC
180
180
90 New BETTER BUILT Vinyl low E
90 New BETTER BUILT Vinyl low E
Zone. (I Common Areas
Zone 11 Common Areas
18 Wind Rear (South) 12.5 0.340 _ILFRC Q8 KERC 180 --gQ New BSI R-BUU_LVbA low E
1. Indicate source either from NFRC or Table, 116A. 2. Indicate source either from NFRC or Table 1168.
Zone II Common Areas
INTERIOR AND EXTERIOR SHADING
Insulation
Condition
Location/
Type Length
R -Val. Location, JA IV Reference
Status
Comments
Slab Perimeter 139
Window
New
Overhang
Left Fin Right Fin
#
Exterior Shade Type
SHGC
Hgt:
Wd.
Len.
Hgt. LE)&
REA Dist. Len. Hgt. Dist. Len. Hgt.
1
Bug Screen
0.76
5.0
_ '&0
2.0
0.1 2.0
2.0
2
Bug Screen
0.76
2.0
2.5
2:0
0.1 2:0
2.0
3
Bug Screen
0.76
4
Bug Screen
0.76
5.0
5.0
20
01 2.0
2.0
5
Bug Screen
0.76
2.0
4.0
2.0
0.1 2.0
2.0
6
Bug Screen
Os76
2:0
X6.0
2.0
0. 2.9
2.0
7
Bug Screen
0:76
2.0
6.0
U.
0.1 2:0
2.0
8
Bug Screen
0:76
7:5
2.0
2:0
0.1 2.0
2.0
9
Bug Screen
0:76
8:0
5.4
2:0
0:1 2.0
2.0
10
Bug Screen
0.76
7.5
2.0
2.0
0.1 2:0
.2.0
11
Bug Screen
0.76
2:0
3.0
ZO
0.1 2.0
2.0
12
Bug Screen
0;76
2.0
2.0
2;0
0:1 2.0
2.0
13
Bug Screen
0:76
2:0
2:0
2.0
0.1 2.0
2.0
1.4
Bug Screen
0.76
20
2.0
2:0
0.1 2:0
2.0
15
Bug Screen
0.76
2.0
2.0
2 0
0.1 2:0
2.0
16
Bug Screen
0.76
7.5
2.0
2.6
0.1 2:0
'2.0
17
Bug Screen
0.76
8.0
5.3
2:0
0.1 2.0
2.0
18
Bug Screen
0.76
7.5
2:0
2:0
'0.1 2:0
2.0
19
Bug Screen
0.76
2.5
5.0
2.0
-Al 2:0
2.0
THERMAL MASS FOR HIGH MASSDESIGN
Area Thick.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
Condition
Location/
Type Length
R -Val. Location, JA IV Reference
Status
Comments
Slab Perimeter 139
None No Insulation 26 Al
New
Zone I Bdrs..
-Slab Perimeter 110
None No Insulation 26-A1
New
Zone II Common Areas
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number. ADY315-1105 Page:4 of 12 1
Certificate Of Compliancei Residential (Part 2 of 3) CF -JR
JOSEPH BIRDSELL 1/10/2006
-Project Title Date
FENESTRATION SURFACES
True Cond. Location/
-# Type Area U -Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
2a Window Rear uth) 125 _0-340 NMG -0.28 -NERC __ 180_ -90_ New EIMFR MALT Vinyl low E Zone It Common Areas
21 Window Rear (South) 4.0 0.340 NFRC 0.28 NFRC 180 90 New BETTER BUILT Vinyl low E Zone II Common Areas
2Z Window Rear Louth 4.0 0.340 NFRC 0.28 NFRC 180 90 New BETTER BUILT Vinyl low E Zone II Common Areas
23 Window Rear (South) 4.0 0.340 NFRC 0_28 NFRC 180 90 New BETTER BUILT Vinyl low E Zone.11 Common Areas
24 Window Right West) 15:0 0.340 NFRC 0.28 NFRC 270 90 New BETTER BUILT Vinyl low E Zone 11 Common Areas
25 Window Right ).West) 42.6 0.340 NFRC 0_28 NFC 270 90 New BETTER BUILT Vinyl low E Zone 11 Common Areas
26 Window Right (Vlle)--15,9 0.349 NEK -028 _NFRC -274 90 h[ew _BETTER BUILT Vinyl low E Zone 11 Cop]mon reas
27 Window Right (West) 17.5 0.340 NFRC 0_28 NFRC 270 90 New BETTER BUILT Vinyl low E Zone II Common Areas
2$ Window Right Mest)__J_7� 0,340 _NFRC -02-8, NFRC 270 90 New BETTER BUILT Vinyl low E Zone 11 Common Areas
22 Window Right (West) --44A 0,340-NFRC 0.28 NFRC 270 -9Q New BETTER BUILT Vinyl low E- Zone II Common Areas
3Q Window Right (Northwest) 42.7 0.340 NFRC 0_28 NFRC 315 90 New BETTER BUILT Vinyl low E Zone 1 G_omm�n Areas
1. Indicate source either from NFRC or Table 116A. 2. Indicate source.either from'.NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Tvne SHGC Hgt. Wd. Len. Hat. LExt. REA Dist. Len. Hat. Dist., Len. Hat.
20
Bug
Screen
0.76
21
Bug
Screen
0.76
_
2.0
2.0
2.0 0.1 2.0
2:0
22
Bug
Screen
0.76
20
2.0
2.0 0.1 2.0
2.0
Bug
Screen
0.76
2.0
-2-0
_2.0 0._1 �2.
2.0
24
Bug
Screen
0.76
7.5
2_0
2.0 0.1 2.0
2.0
25
Bug
Screen
0.76
8.0
5_3
2.0 01 �2.
20
26
Bug
Screen
0.76
7.5
2:0
2.0 0.1 2.0
2.0
27
Bug
Screen
0.76
3.5
5:0
2.0 01 2.0
2.0
28
Bug
Screen
0.76
3.5
5.0
2.0 0.1 2.0
2.0
29
Bug
Screen
0.76
30
Bug
Screen
0.76
8.0
5.3
2.0 0.1 2.0
2.0
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick:.Heat Inside Condition Location/
Type (sf) (in.) Cap. Cond.,R-Val. JA IV Reference Status Comments
PERIMETER LOSSES
Insulation
R -Val. Location
Condition Location/
JA IV Reference Status Comments
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY315-1105 Pace'.5,of 12 1
Certificate Of Compliance : Residential
(Part 3 of 3)
CFA R
JOSEPH BIRDSELL
-Project Title
R -Value Status
Tested?
Date
1/10/2006
HVAC SYSTEMS
Location.
Heating
Type
Minimum Cooling
Eff; Type
Minimum Condition Thermostat
Eff Status Type
HVAC Split System Zn l
Central Furnace
80% AFUE Split Air Conditioner
13.0 SEER New
Setback
HVAC Split System2n„II
Central Furnace
80% AFUE SplitAir.Conditioner
13,0 SEER New
Setback
HVAC DISTRIBUTION
Duct
Duct Condition
Ducts
Location Heating Cooling Location
R -Value Status
Tested?
HVAC Split System Zn I Ducted Ducted Attic
8.0 New
No
HVAC Split.System Zn 11 Ducted Ducted Attic
8:0 New
No
Hydronic Piping Pipe Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Ratedl
Tank
Energy
Standbys Tank Insul.
Water Heater # in Input
Cap.
Condition Factor
Loss R -Value
System Name Type. Distribution Syst. (Btu/hr)
(gal)
Status or RE 1
(%) Ext.
A:O. SMITH FPS -50-224 Small Gas No Pipe Insulation 1 43,000
50
New 0.65
n/a Na
Multi -Family Central Water Heating Details
Hot Water Pump Hot Water Piping+Length (ft) Add 1/2”
Control # HP Type In Plenum Outside Buried Insulation
1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump.water heaters, list energy factor.
For large,gas storage water heaters (rated input > 75000 Btu/hr)', list Rated' Input; Recovery Efficiency and Standby Loss.
For instantaneous gas water`heaters list Rated Input, and Recovery Efficiency.
COMPLIANCE STATEMENT
This certificate -of compliancelists4he building features and, specifications neededto comply with Title 24, Parts 1 and 6 of the California Code of
Regulations, and the administrative `regulations to implomentthem:This certificate hasbeen signed by thelindividual with. overall design responsibility.
The u igned recognizes:that'compliance using, duct design, duct sealing, Verification of refrigerant charge:and TXVs, insulation installation quality,
ulldin envelope seali%sequire installer testing and certification, and field verification byan'approved HERS rater.
Designer o O r er�!siness:.$ Professions Code) Documentation Author
Name: ADRIANA GIL
Title/Firm: OWNER Title/Finn: Adriana Gil
Address: MR. JOSEPH BIRDSELL Address: '74-854Veiie Way'Ste..#8
LA QUINTA, CA Palm Desert, CA 92260
Telephonej Telephone: -(760) 404-791
Lica.#;
/d /Ojz
(signature) (date) (signatu (date)
Enforcement; ency
Name:
-Title/Firm:
Address:
Telephone:
Certificate Of Compliance : Residential (Addendum) CF -1 R
JOSEPH ORDSELL 1/1.0/2006
Project Title Date
Special Features and Modeling Assumptions
The local enforcement agency;should pay special attentionto'the.items specified in this,checklist. These itemwrequire special
written justification and documentation, and special verlficatlomto be used with the performance•approach. The local enforcement,
agency determinewthe-adequacy ofthe justification, and may reject a building or design that,otherwlse complies based on the:
adequacy of,the;speclal justification and documentation submitted. Plan Field
Compliance using the"iFourCardinal Orientation approach,has been used. Project can be;builfln"any Orientation.
The Roof "R-38 Roof (R.38:2x4.24)" includes credit:for a Radiant Barrier installed per Section 3.3.3 of the Residential Manual.
HERS Required Verification,
Items In thls.section require field testing and/or verification by a certified home energy rater under the supervision of a CEC-
approved HEMprovider using CEC approved testing.and/or verification methods and must bexe.ported on the CFAR Plan Field
Installation certificate.
The HVAC IZystem "HVAC Split System Zn I" incorporates a.HERS verified. Refrigerant Charge testiora HERS verified'Thermostatic
'Expansion Valve.
The Cooling System 'Fork 1-14DH04803HUB161-065 U&H" includes credit for a 11.5 EER Condenser: A, certified HERS'rater must
field verify the installation of the correct:Condenser.
The HVAC System "HVAC Split System Zn II" incorporates a, HERS verified Refrigerant Charge testora HERS verified Thermostatic
Expansion Valve.
The Cooling System "York H4DH036S06/P3HUA053 U&H" includes credit fora 11.5 EER Condenser._ A certified' HERS rater must
field'verify the installation of the correct.Condenser:
EnergyPro 4.0 by EnergySoft User. Number. 5553' Job Number. ADY315 1105 Page:7 of 12
Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R
NOTE: Low-rise residential buildings subject to the Standards mustcontain these°measures regardless of the compliance approach used. More stringent compliance
requirements from the Certificate otCompliance supercedes the items marked with and asterisk (')ibelow. When this checklist is incorporated into She permit
documents,ahe features noted shall be considered by all parties as minimum componentperformance specifications for the mandatory. measures whether they,are
shown elsewhere in the documents or on this checklist only.
DESCRIPTION Instructions: Check or initlal applicable boxes when completed or check NIA H not
applicable:
NIA
DESIGNER
ENFORCE -
MENT
Building Envelope Measures
❑X
❑
❑
§ 150(a): Minimum R-19 in`wood ceiling insulation or equivalent U -factor in metal frame ceiling.
❑
❑X
❑
§ 150(b): Loose fill insulation.manufacturer's labeled R -Value:
❑X
❑
❑
§ 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame.walls (does not
❑
❑X
❑
apply,to exterior mass wails).
❑
❑
§ 150(d): Minimum R-13 raised floor insulation inframed'floors or equivalent U -factor..
LK
❑,
❑
§ 150(e): Installation of Fireplaces, Decorative�Gas Appliances and Gas Logs.
❑X
❑
❑
1-. Masonry and factory -built fireplaces 'have;
❑
0
❑
a. closable metal or glass door covering the entire -opening of, the firebox
❑
❑
b. outside air intake With damper.and control, flue'damperand control
❑X
❑
❑
2. No continuous'buming.gas pilot lightsellowed.
❑
❑
§ 150(f): Airretarding wrap installed.to comply with §151 meets requirements specified in the,ACM Residentiaf Manual.
R
❑
❑'
§ 150(g); Vapor barriers mandatory in Climate Zones 14 and 18 only.
❑X
❑
El
§ 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor
❑X
❑,
❑
permeance rate no greater than. 2.0 permfinch.
Q
❑
❑
§ 118; Insulation:specified or installed meets insulation installation quality standards. Indicate type and include
❑
a,
❑
CF-BR,Form:
❑X
❑
❑
§ 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls.
1. Doorwand.windows'between conditioned and unconditioned spaces designed to limit air leakage..
❑X
❑
❑
2: Fenestration products (except field fabricated), have label With, certified U -Factor, certified Solar Heat Gain
Coefficient
o
❑,
❑
(SHGC), and infiltration certification.
3. Exterior doors and windows weatherstripped; all,joints and' penetrations caulked and sealed.
❑X
❑
❑
pace. Conditioning, Water Heating and Plumbing System Measures
§ 110-13: HVAC equipment,,waterheaters, showerheads and faucets certified by the Energy: Commission.
J
❑
❑
§ 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or-ACCA.
❑X
❑
❑
§ 150(i): Setback thermostat on all applicable heating and/or cooling systems.
❑
0
❑
§ 1500): Water system pipe and tank insulation and cooling systems line insulation.
1. Storege,gas water heaters rated.with an Energy Factor less.than 0.58 must be: externally wrapped with insulation
❑
❑
having an installed thermal resistance of R-12,or greater.
2. Back-up tanks forsolar systems, urfired storage tanks, or other,indirect hot water tanks ha wR-l2,extemal
Q
❑
❑
insulation or R-16 internal insulation and indicated on,the'exteriorof the tank showing the R -value.
3. The following piping is insulated according to Table 150-A/B or Equation 156-A Insulation' Thickness:
1. First 5'feet of hot and cold'water pipes closest to water heater tank, non -recirculating systems, and entire
Q
❑
❑
length of recirculating sections of hot water pipes shall be`insulated to Tattle 150B.
2. Cooling system piping (suction, chilled water, or, brinelines), piping insulated between heating source and
❑X
❑
❑
indirect;hot water tank shall be insulated to Table 150-8 and Equation 150-A.
4. Steam hydronic'heating systems or hot water systems > 15 psi, meet requirements of Table 123-A.
❑
❑
5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance,
41
❑
❑
and wind.
6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed
❑X
❑
❑
entirely in conditioned space.
7. Solar water -heating systeriWcollectors are certified by the Solar Rating and Certification Corporation.
❑X
❑
❑
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY31&1105
Page:8 of 12
Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless ofthe compliance approach used. More stringent
compliance requirements from the Certificate of Compliance supercede the items marked with an°asterisk (*) below. When this checklist is incorporated
intothe perrnit,documents, thefieatures noted shall be considered by all parties as minimum component performance specifications for the mandatory
measures whether they are shown elsewhere in the documents, or on this checklist only.
DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A If not ENFORCE-
applicable. NIA DESIGNER MENT
Space Conditioning, Water Heating and Plumbing System Measures- (continued)
§ 150(m): Ducts and Fans
1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 60.3, 604,
Q ❑ ❑
805, and Standard 6-5; suppyair and return-airducts and plenums are insulated,to a minumum installedlevel of
R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct-closure.system
that meets the applicable requirements of UL 101, UL 181A, or UL181 e:or aerosol sealant that.meets the requirements
of UL 723. if mastic or tape is used to seal openings, greater than 11.4 inch, the combination of mastic and either mesh
or tape shall be used. ,
2. Building,cavities, support platforms for air handlers, and plenums defined or constricted with materials other than
X❑ ❑ ❑
sealed sheetmetal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and
support platforms may contain ducts. Ducts installed in cavities and support platforns,shall not be corripressedto.cause
reductions in the cross-sectional area of the ducts.
3. Joints and seams of duct systems and their components shall not be sealed.with cloth back rubber adhesive
0 ❑ ❑
duct tapes unless such tape. is used in combination with mastic and draw bands.
4. Exhaust fan systems have back draft or automatic dampers.
® ❑ ❑
5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating
® ❑ ❑
dampers.
S. Protection of Insulation. Insulation.shall be protected from damage, including that due to sunlight, moisture, equipment
❑x ❑ ❑
maintenance, and wind. Cellular foam insulation shall be protected as above or painted with.a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material.
7. Flexible ducts cannothave porous innercores.
x❑ ❑ ❑
§ 114: Pool and Spa Heating Systems and.Equipment
1..A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off'switch mounted outside of the
Q ❑ ❑
heater, weatherproof, operating instructions; no electric resistance heating and no pilot light.
2.. System: is installed with:
a..At least 36" of pipe between filter and heater for future solar heating.
❑ ❑
b. Cover for outdoor pools or outdoor spas.
X❑ ❑ ❑
3.. Pool system has directional inlets and a circulation pump time switch.
❑X ❑ ❑
§ 115: Gas fired fan -type central'fumaoes, pool heaters, spa heaters or household cooking appliances have no continuously
❑ ❑
burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)
§ 118 (i): Cool Roof material'meets specified criteria
x❑ ❑ ❑
Lighting Measures
§ 150(k)1; HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table
❑ ❑
150-C, and do not contain a medium screw base socket, (E24%E26). Ballastsfor lamps 13 Watts or greater are
electric and have an output frequency no; less than 20 kHz.
§ 150(k)1: HIGH EFFICACY LUMINAIRES -OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C,
Q ❑ ❑
luminaire has factory installed HID ballast:
§ 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy, luminaires. Up to 50% of the Wattage, as determined
❑ ❑X E]in
Section 130(c), of permanently installed luminaires in kitchens may be in luminaires -that are not high efficacy luminaires,
provided that,these luminaires are controlled'by switches separate from those controlling the high efficacy luminaires.
§ 150(k)3: Pernarientiy`installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall, be high efficacy luminaires.
❑ ❑
OR are controlled by an occupant sensor(s) ceritfied.to comply With ;Section 119(d)..
§ 150(k)4: Permanently installed luminaireslocated other than in kichens, bathrooms, ggarages, laundry rooms, and utility rooms
shall be high efficacy luminaires (except closets less than 7.0'ft) OR are,controlled by a dimmer switch OR are
X❑ El Elcontrolled
by an occupant sensor that complies with Section ll 19(d) that does not tum on automatically or have an
always on option.
§ 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are
❑X ❑ ❑
certified to. ASTM E283 and labeled as air tight (AT) to less than.2.0 CFM at 75 Pascals.
§ 150(k)8: Luminaires providing outdoorlighting and permanently mounted to a residential, building or to other buildings:on the ❑ ❑
same lot shall be high efficacy'luminaires (not including'lighting around swimming pools/water features or other Article
680 locations) OR arecontrolled by occupant sensors wwth.integral photo control oertifiedto comply with Section 119(d).
§ 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with:Sections 130, 132, and 147. FX] ❑ ❑
Lighting for parking garages for 8 ormore vehicles shall have lighting,that complieswith Section 130, 131„ and 146.
§ 150(k)8`. Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential'buildings with fouror more X❑ ❑ ❑
dwelling units shall lbe-high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with, Section
119(d).
EnergyPro4.0 by EnergySoft User Number: 5553 Job+Number: ADY315-1,105 Page:9 of 12
Residential Kitchen Lighting Worksheet WS -SR
JOSEPH BIRDSELL 1110/2006
- Project71tle Date
_ At least 50% of the total rated wattage of permanently installed luminaires In kitchens must be In luminaires that are high efficacy luminaires
awdefined in Table 150-0. Luminaires that are not high efficacy must be switched separately.
Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed In kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
(1)26w Compact FluorescenMuad 2 Pin Yes X No F_ 37.0 x 12 444 or
Yes I ;No I x = or
Yes' No x or
Yes No x = or
Yes No x = or
Yes' No x = or
Yes No x = or
Yes No x = _ or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes No . x = or
Yes No x = or
Yes No x = or
Yes 0 No_I x = or
Total A: 444 B: 0
COMPLIES IF A Z B YES k NO ❑
EnergyPro 4.0 by EnergySoft User Number: 5553 Job Number: ADY315-1105 Pane: 10 of 12 1
IVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME
SYSTEM NAME
PH BIRDSELL
Zn '1
26.0 of
Outside. Air
0 dm
68.7 of
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
DATE.
1/1
FLOOR AF
COIL COOLING PEAK
COIL HTG. PEAK
CFM I
Sensiblel
Latent
CFM
Sensible
23,564 2,723
23 930
York H4DH048/P3HU1316L065 U&H 31,679 11,133 80,000
Total Adjusted System Output 31,679 11,133 80,000
(Adjusted for Peak Design Conditions)
TIME OF SYSTEM PEAKAug 2pm Jan 12 am
68.7 of 68.7 of 115.70F
Supply Fan Heating Coil
1600 cfm
,n ouppiy mir vucts 7
114.5 of
ROOMS
70.0 of
Return Air Ducts I
111.0 / 77:6 of 77._5164,9 OF 7T5 / 64.90F58.9•/ 57.9 OF
Outside Air
0 cfm Supply Fan
1600 dm
- � 77.5164.9 of
Cooling Coil
Of
h Return Air Ducts 'I
Supply Air Ducts
60.4158A OF
53.7% R.H. 1 ROOMS
76.Q/ 64.4 of
EnergyPro.4.0 by EnergySoft User,Number. 5553, Job Number ADY315-1105 Page: 11of 12
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
_ JOSEPH BIRDSELL 1/10/20.06
SYSTEM NAME FLOOR AREA
HVAC Split System Zn '11 1,167
Number of S stems
1
Heating System
Output per System
63,000
Total Output (Stub)
63,000
Output (Stuh/sgft)
54:0
Cooling System
Output per System
35,200
Total Output (Btuh)
35,200
Total Output (Tons)
29
Total Output (Btuh/sgft)
30:2
Total Output (sgft/Ton)
398.0
Air System
CFM per System
1,200
Airflow Wm)
1,200
Airflow (chWsgft)
1.03
Airflow (cfm/Ton)
409.1
Outside Air (%)
0:0
Outside Air (cfm/sgft)
0.00
NOW values above given at ARI
26.0 of
Outside Air
0 drn
68.5 OF
68.5 OF 68.5 OF
Total Room Loads
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL COOLING PEAK
COIL HTG. PEAK
CFM
I Sensiblel Latent
I CFM
Sensible
1,205
17,706
2,345
355
17,491
0
2,422
1,916
0
0
0
0
0F
0
0
0
2,422
1,916
22,550 2 345 21,322
York H4DH036S061P3HUAO53 U&H 22,473 9,456 63,000
Total Adjusted System Output 22,473 9,456 63,000
(Adjusted'for Peak Design Conditions)
TIME OF SYSTEM PEAK Aug.2 pm Jan 12.am
1,17:8'9F
Supply Fan Heating Coil
1200 cfm
h Return Air Ducts �
Supply Air Ducts
116.30F
ROOMS
70.0 of
I
111.0:/ 77.6 of 77.9165:9 of 77.9 / 66.0 of 60.3 59.3 OF
Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 62.2/60.0 of
1200,cfm 56.9% R.H. IRIDOWS
77.9165.9 of 76:0 / 65.3 of
Return Air Ducts I
EnergyPro 4'.0 by'EnergySoft User Number: 5553 Job Number: ADY315-1105 Page: 12 of 12