Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-1320 (RER)
P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 09-00001320 Property Address: 49757 COACHELLA DR APN: 646-230-013- - - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 175000 T4tvl 4 4 Q" BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Owner: MR & MRS LEW PRICE 49-757 COACHELLA DRIVE LA QUINTA, CA 92253 Contractor: Applicant: Architect or Engineer: CLARK JR, JACK L. 51220 AVENIDA CARRANZA LA QUINTA,- CA 92253 A(760) 564-3511 _ NLic. No.: 506667-------------------------------------------------------------------------- D LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I. am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: 13 License No.: 506667 ate: /' ' / ' /� tractor: i` I ✓CE OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or.offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor (s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 2/09/10 WORKER'S CO PEN TION DECLARATION 1 hereby affirm under penalty of perjury one of the folio Ing �6T vDt!?Itu��'11"1,11 !.tion,have and will maintain a certificate of conent to sel a sation, a provided for by Section 3700 of the Labor Code, or the perfor0.f� �r which this rmit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier E MPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section _ 3700 of the Labor C de 1 shall forthwith co m ly with those provisions. /♦ 1; e: ,Z -q �o applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Ouinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to b 'Id' construction, and hereby authorize representatives of s)tis county toen;uponur'e above-mentioned propeyfd ��� tion`/ -Date: (Applicant or Agent): Application Number . . . . . 09-00001320 Structure Information REMODEL+523SF PATIO CVR ADDITION [ENG] Other struct info . . . . . CODE EDITION 2007 ----------------------------------------- # BEDROOMS ----------------------------------- 2.00 Permit ELECT-- ADD/ALT/REM Additional desc . . Permit Fee . . . . 104.04 Plan Check Fee 26.01 Issue Date . . . . Valuation 0 Expiration Date 8/03/10. Qty Unit Charge Per Extension BASE FEE 15.00 2544.00 --------------- .0350 ----------- ELEC NEW RES - 1 OR 2 FAMILY --------------------------------------- 89.04 ----------- Permit BUILDING PERMIT Additional desc . Permit Fee . . . . 902.00 Plan Check Fee 586.30 Issue Date Valuation . . . . 175000 Expiration Date 8/03/10 Qty Unit Charge Per Extension BASE FEE 639.50 75.00. ---------------------------------------------------------------------------- 3.5000 THOU BLDG 100,001-500,000 262.50 Permit MECHANICAL Additional desc'. Permit Fee . . . . 104.00 Plan Check Fee 26.00 Issue Date . . . . Valuation . . . . 0 Expiration Date 8/03/10 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 9.0000 A EMECH FURNACE <=100K 9.00 1.00 11.0000 EA MECH FURNACE >100K 11.00 1.00 4.5000 EA MECH VENT INST/ DUCT ALT 4.50 1.00 9.0000 EA MECH B/C <=3HP/100K BTU 9.00 1..00 16.5000 EA MECH B/C >3-15HP/>100K-500KBTU 16.50 5.00 6.5000 EA MECH VENT FAN 32.50 1.00 ----------------- 6.5000 ----------------------------------------------------------- EA MECH EXHAUST HOOD 6.50 Permit . . . PLUMBING Additional desc . Permit Fee . . . . 121.50 Plan Check Fee 30.38 LQPERMIT Application Number . . . . . 09-00001320 Permit . . . . . . PLUMBING Issue Date . . . . Valuation . . . . 0 Expiration Date 8/03/10 Qty Unit Charge Per Extension BASE FEE 15.00 14.00 6.0000 EA PLB FIXTURE 84.00 1.00 7.5000 EA PLB WATER HEATER/VENT 7.50 -1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 4.-00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 12.00 ---------------------------------------------------------------------------- Special Notes and Comments INTERIOR REMODEL WITH 523SF PATIO COVER ADDITION/VB/RES-3/CLASS A [ENGINEERED] THIS PERMIT DOES NOT INCLUDE ADDITIONAL SQUARE FOOTAGE OR UPGRADING OF EXISTING ELECTRICAL SERVICE. 2007 CALIFORNIA BUILDING CODES. February 4, 2010 10:24:09 AM AORTEGA -------=-------------------------------------------------------------------- Other'Fees . . . .. . . . . . BLDG STDS ADMIN (SB1473) 7.00 ENERGY REVIEW FEE 58.63 STRONG MOTION (SMI) - RES 17.50 Fee -summary Charged Paid Credited. -------------------- Due ------------------------------------- Permit Fee Total 1231.54 .00 .00 1231.54 Plan Check Total 668.69 .00 .00 668.69 Other Fee Total 83.13 .00 .00 83.13 Grand Total 1983.36 .00 .00 1983.36 0 0 LQPERMIT - d Z CITY- OF LA QUINTA ' SUB -CONTRACTOR LIST JOB ADDRESS PERMITNUMBER OWNER. Lew ?Tr ce-' It10.DER J'AC CLv�t K "AST. - 'this tam ahall be ooskil an ttm}ob wfth thedk n esti.-,:. Card conimbus eiam. Only Perms appearing at an thnes in a s an this 'ob. A �""'•��p ori off this fist or tbafr employees are authorized to wort y ny-dunges to this list must be approved by the 8u➢Idktg Division prior to commencement of work. Failure to compty WiiH re Ult in a stoppage of work and/or the voidanct M hugdina permit. For each anmieahiA trwiA. aM tniAr n.#i n t•.ai_.......s M .........1 •..i t... rrti rums [- .rs�►.Iw �.........a s rade ¢ tisi8tr Conv eov *a" Ctsuftatton (e.g. A., B, C41) s" ticomm /Aimber txax. : _ Env @aft bxbxxxl ,,,;� 'c' •�r> . •�., .:�,.'« . CWdW Un" Pocky Numbtr I xp. Oat* tAa Oomatvad") txx/xxkxi leensea"Un* tioaq t'Gr\p�, Deft tuhmfxx�l0 EAaaWOKtc=as Jcr Fuwa'c o n .- o C-8 Q 7B _S1h �l(aS to. Io3ss5' �SQNRY (C-283 . t viuldaotc.as3&f4LVA PL.ump,� " G -S 3an Bill ST `o 40&s& o I/o /01/0- 1\5 a C;;;Io TILE• ter") C4 6WNEf8 IC -81 FWUN© IC -131 LA WSCAP G tC-=. POOL lC-531 We BU ST P. P --t�- ffpc,,v B, # City of La Quinta Building 81: Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # 4 V� Project Address: — 7J C/D Owner's Name: Wet t__f gill Pp4ce A. P. Number: *`4 2 �! 0 O �f' Address:g t 2 Legal Description: �[_III �C RXV 18 �� 7� 7 r l� City, ST, Zip: Lb'= CQL,%C)-J Tv -6- • Contractor: Tele P hone: �#. �"•.�,>.;:�;:�::;•. M:. }-.�.,,� Address: Project Description: City, ST, Zip:i�Q! Telephone: f�?�r • �y�":::k«^�.r4,k ..:.?%'":� State Lic. #: City Lic. Designer. pr r-o� �1 n M M X11 y, Address: ! % ZiZ e:ZuYP.�t c wp �rls y 1 11 I L `� t u 111 City, ST, zip: Co- 917-71 %6Cj�//� aTelePhone: :-w<. �k✓ OccupancyConstructConstruction . � State Lic. #: 1 �Ad nd nd Alter Repair project type (circle onj .y N=ew Demo Name of Contact Person: UC>5 Sq. Ft #Stories: # Units: Telephone # of Contact Person: Wo Z Estimated Value of Project: �5 ��t� APPLICANT: DO NOT WRITE BELOW THIS LINE N Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets a Pian Check submitted Item Amount Structural Cale& A Reviewed, ready for corrections 11� 2&10 Plan Check Deposit Truss Calcs. Called Contact Person Plaa Check Balanee. Titre 24 Cales. a Plans picked up Construction Flood plain plan Plans resubmitted 1 �to Mechanical Grading plan 2`! Review, ready for correctio r ue to Electrical Subcontactor List Called Contact Person Al IRAto Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval , Plans resubmitted Grading IN HOUSE:- ''' Review, ready for correctionstissue Developer Impact Fee Planning Approval Called Contact Person I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 1113 Zone uS 1 41 ("to Pgorsolot av ISLANDS 2 HOMEOWNERS COMMUNITY ASSOCIATION November 20 ,20.09. To Whom It may Concern The Board of Directors,.for'the Islands 2 Home,Owners.Association have reviewed the plans submitted by Lew: and Diane Price for their remodel at 49 757 Coachella Drive La Quints, California.:.: Since.the. remodel is :aln .ontimly. interior except for the raising of the patio roof and does not require any addid6nal votes. from the home owners, the Board approves the plans. Additionally. the Board: feeis'-.that these plans although shared with the Management Company do not.need approval. If there: are any further questions the Board of Directors of Islands 2 will be glad to answer them. Submitted by 7 Kay Ruttman, President, Islands 2. Homeowners Asspciation. Y: DLCO cc: Dave. Patrick, .Board of.Iliiectors DEC 3 0 2009 Connie Kaiser,'Board.`of Directors Rosie Galla, Pro ger BY --- =Management Management Croup I' TITLE 24 REPORT I Lt Title 24 Report for: Mr. & Mrs. Lew Price 49-757 Coachella Dr. La Quinta, Ca 92253 Project Designer: Robert A. Pitchford, Design & Drafting 77-622 Country Club, Suite, O Palm Desert, CA 92211 (760) 346-2856 ' Report Prepared By: Tim Scott Scott Design & Title 24 77085 Michigan Dr. Palm Desert, CA 92211 (760) 200-4780 dMoo CITY OF LA QUINTA BUILDING & SAFETY DEPT. Job Number: (APPROVED FOR CONSTRUCTION DATE VQ M10 BY. Date: 01-IS1,o - -I ARta 4AW. 1/29/2010 he EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is uthorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. I' EneravPro 4.4 by EneravSoft Job Number: User Number: 6712 1 TABLE OF CONTENTS Cover Page Table of Contents Form CF -1 R Certificate of Compliance Form MF -1 R Mandatory Measures Summary Form WS -5R Residential Kitchen Lighting HVAC System Heating and Cooling Loads Summary Room Load Summary Room Heating Peak Loads Room Cooling Peak Loads 1 2 3 7 9 10 12 14 16 EnergyPro 4.4 by EnergySoft Job Number: User Number: 6712 -- Certificate Of Compliance : Residential (Part 1 of 3) CF -1 R fir_ & MrsIew PriDe 2,544 ft2 Existing Floor Area: 1/29/2010 oject Title Raised Floor Area: 0 ft2 Date 4-75ZCnerhe-ll ne_ r I Qltinta Average Ceiling Height: 10.0 ft Project Address .a Number of Stories: Building Permit # Sco nesion & Title 24 (,760) 200-4780 Documentation Author Telephone Plan Check/Date EneravPro CompliWdce Method CA Climate Zone 15 Climate Zone Field Check/Date TDV Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating 10.77 6.07 4.70 Space Cooling 154.07 127.94 26.14 Fans 21.46 18.41 3.06 Domestic Hot Water 10.36 9.92 0.44 Pumps 0.00 0.00 0.00 Totals 196.68 162.34 34.34 Percent better than Standard: Building Type: Y Single Family ❑ Multi Family Building Front Orientation: Fuel Type: Fenestration: ❑ Addition Q Existing + Add/Alt (N) 0 deg Natural Gas Area: 531 ft2 Avg. U: 0.39 Ratio: 20.9% Avg. SHGC: 0.37 Total Conditioned Floor Area: 2,544 ft2 Existing Floor Area: 2,544 ft2 Raised Floor Area: 0 ft2 Slab on Grade Area: 2,544 ft2 Average Ceiling Height: 10.0 ft Number of Dwelling Units: 1.00 Number of Stories: 1 4LDING ZONE INFORMATION # of one Name Floor Area Volume Units Zone Type HVAC 1 Altered 147 14 75r1 n 58 CnndifinnPd HVAC 2 1 069 10 590 X42_ Conditioned OPAQUE SURFACES Insulation Act. Type Frame Area U -Fac. Cay. Cont. Azm. Tilt Rnnf Wnnd 1,475 _0035 R_30 R -n n 145 90 Wall Wnnd 128 _0 356 Nnnp R -Q 0 34`s—flo moor None 24 1.450 None R-0 0 345 90 Wall Wnnd 231 n 10 R_11 R-Qn 345 An Wall Wnnd 286n456 None R-0_ 75. _9Q Wall Wood 200 0.102 R-13 RR 0.0 165 90 Wall Wnnd 96 . n�i56 Nnnp -n 0__ _95_ An Rnnf Wnnd _ 11 460 n n35 R -3n R_0 0 _ 345 2n Wall Wood 136 0.356 None R -n n _ 345 90 Wall Wnnd 1100456 None R-0 0 7`.i_90 Wall Wnnd 25 n JQ9 R_13 R -n n 165 _An Wall Wnnd 85 X3SS Nnnp R -n n 165 qn Wall Wood 386 0 356 Nene Q_0_0 25.5 go Thermostat Vent Type Hgt. Area Setback— —2 n/a Setback n/a Gains Condition Y / N Status JA IV Reference Location / Comments IN ❑Altered n2 -A10 (F=m A2) I 7nne AltPrPd ® ❑Fxisting 09-A1 I ivina one Altered ® ❑Fxicti 9_ 28-A1 IiVjp9 Zone Altered ® ❑Altered n9 -A3 (FF=09-A1)I ivi g7nne Altered IN ❑Existing 09-A1 -Loving- on ,Altered ® ❑Altered 09-A3 (F=09 -Al) iving Zone Altered ® ❑Fxisting 09-A1 I 7on - Altered ® ❑Altered _02-A10 (F=01 -A21 SIPP_pipa 7nne Altered ® ❑Fxicting 09-A1 Sleenina Zone Altered ® ❑Existing_ 09-A1 SIPPpena Zone Altered ® ❑Altered 09-A3 (F=09 -A1) Sleeping 7nne Altered ® ❑Fxisfin 09-A1 SIPeping7nnP Altered F-1 �Fxi¢ting 09-A1 Sleenina 7nne Altered ❑ ❑ ❑❑ ❑❑ ❑❑ ❑❑❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:3 of 17 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R AMr. & Mrs. Lew Price 1/29/2010 oject Title Date FENESTRATION SURFACES True Cond. Location/ # Tvpe Area U -Factor' SHGCZ Azm. Tilt Stat. Glazing Tvpe Comments 1 Window Front (N) 32.2 _0 39 NFRC OT37 NFRC 345 qQ Altered Double Non Metal Tinter/ _ Liyino Zone Altered 2 Existing 0.76 0.990 116-A 0_74 116-B Single Non Metal Clear pre -altered for above 3 Window Front (M 20.1 0.990 116-A 0.74 116-B 345 90 RemovedSingle Non Metal Clear Living Zone Altered 4 Window Front (N) 32.2 0.990 116-A 0.14 116-B 345 90 RemovedSingle Non Metal Clear Living Zone Altered 5 Window Front (N) 15.0 0.990 116-A 0.74 116-B 345 90 RemovedSingle Non Metal Clear Living Zone Altered 6 Window Front (N) 15.0 0_990 116-A 0_74 116-B 345 90 RemovedSingle Non Metal Clear Living Zone Altered L Window Front (N) 15.0 0.990 116=A 0_74 116-B 345 90 RemovedSinale Non Metal Clear r LMon Zone Altered 8 Window Front (N) 9.4 0.390 NFRC 0.37 NFRC 345 90 New Double Non Metal Tinted Living Zone Altered 6 Window Front (j) 23.5 _0.39014F$C-O-3I NFRC 345 90 New Double Non Metal Tinted Living Zone Altered -ID Window Left (E)- 52.3 0.390 NFRC 0.37 NFRC 75 90 AlteredDoubleNon Metal Tinted Living Zone Altered 11 Existing 0_990 116-A 0.74 116-B Single Non Metal Clear pre -altered for above 12 Window Rear (S) 99.2 0.990 116-A 0.74 116-B 165 90 RemovedSingle Non Metal Clear Living Zone Altered 13 Window Rear (S) 118.4 0.390NEBG 0.37 NFRC 165 _ 90 New Double Non Metal Tinted Livong Zone Altered 14 Window Rear (S) 99.2 0.990 116-A 0.74 116-B 165 90 RemovedSingle Non Metal Clear Living Zone Altered 15 Window Rear (S) 118.4 0.390 NFRC 0.37 NFRC 165 90 New Double Non Metal Tinted Living Zone Altered 16 Window Left (E) 9.0 0.390 NFRC 0.37 NFRC 75 90 New Double Non Metal Tinted Sleeping Zone Altered 17 Window Left (E) 6.0 0.990 116-A 0_74 _l 1F -B 75 90 RemovedSingle Non Metal Clear Sleeping Zone Altered 18 Window Left (E) 9.0 0.390 NFRC 0.37 NFRC 75 90 New Double Non Metal Tinted Sleeping Zone Altered 12 Window Rear (Si _ 80.4 0_390 NFRC 0_37 NERC 165 90 New Double Non Metal Tinted Sleeping Zone Altered 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 1168. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 Bug Screen 0.76 Bug Screen 0.76 _ Bug Screen 0.76 6 Bug Screen 0.76 T- T- Bug Screen 0.76 I 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Insulation Condition Location/ Type Length R -Val. Location JA IV Reference Status Comments Slab Perimeter 103 None No Insulation 26-A1 Existinq Living Zone Altered Slab Perimeter 20 None No Insulation 26-A1 Existing Living Zone Altered Perimeter 80 None No Insulation 26-A1 Existing Sleeping Zone Altered b Perimeter 35 None No Insulation 26-A1 Existing Sleeping Zone Altered Run Initiation Time: 01/29/10 13:30:55 Run Code: 1264800655 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:4 of 17 Certificate Of Compliance : Residential (Part 2 of 3) CF -1 R AMr. & Mrs. Lew Price_ NWoject Title Date 1/29/2010 FENESTRATION SURFACES # Type Area U-Factorl SHGC2 True Azm. Tilt Cond. Stat. Glazing Type Location/ Comments 211 Window Rear ($) _ An 0 0_990 1118-A 0_74 116_B 165 moo-RemovedSinale Non Mtal Clear Sleeping Zone Altered 21 Window Right (W) 9.0 0.390 NFRC 0.37 NFRC 255 90 New Double Non Metal Tinted Sleeping Zone Altered 22 Window Right (W) 6.0 0.990 116-A 0_74 116-B 255 90 RemovedSingle Non Metal Clear Sleeping Zone Altered 23 Window Right (W) 9.0 0.390 NFRC 0.37 NFRC 255 90 New Double Non Metal Tinted Sleeping Zone Altered 24 Window Right (W) 8.0 0.390 NFRC 0_37 NFRC 255 90 New Double Non Metal Tinted Sleeping Zone Altered 25 Window Right (W) 52.3 0.390 NFRC 0.37 NFRC 255 90 Altered Double Non Metal Tinted Sleeping Zone Altered 2E Existing 0_990 116-A 0_74 116.6 Single Non Metal Clear pre -altered for above 1. Indicate source either from NFRC or Table 116A. 2. Indicate source either from NFRC or Table 116B. INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. I -Ext. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 20 Bug Screen 0.76 Ti Bug Screen 0.76 Bug Screen 0.76 46- Bug Screen 0.76 Buq Screen 0.76 25 Bug Screen 0.76 THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Condition Location/ Type (sf) (in.) Cap. Cond. R -Val. JA IV Reference Status Comments PERIMETER LOSSES Tvoe Insulation R -Val. Location Condition Location/ JA IV Reference Status Comments Run Initiation Time: 01/29/10 13:30:55 Run Code: 1264800655 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:5 of 17 Certificate Of Compliance : Residential (Part 3 of 3) CF -1R Aftr. & Mrs. Lew Price 1/29/2010 eject Title Date HVAC SYSTEMS HVAC DISTRIBUTION Location HVAC 1 Altered HVAC Heating Cooli Ducted Ducted Duct Duct Condition Ducts Location R -Value Status Tested? Attic 4.2 New No Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. 4.2 New No WATER HEATING SYSTEMS Rated Heating Minimum Cooling Minimum Condition Thermostat Location Type Eff Type Eff Status Type HVAC 1 Altered Central Furnace 80% AFYE Split Air Conditioner 14.0 SEER Altered Setback pre -altered for above Central Furnace 80% AFUE Split Air Conditioner 10.0 SEER Setback HVAC 2 Central Furnace 80% AFUE Split Air Conditioner 14.0 SEER New Setback HVAC DISTRIBUTION Location HVAC 1 Altered HVAC Heating Cooli Ducted Ducted Duct Duct Condition Ducts Location R -Value Status Tested? Attic 4.2 New No Ducted Ducted Attic Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. 4.2 New No WATER HEATING SYSTEMS Rated Tank Energy Tank Insul. Water Heater # in Input Cap. Condition Factor Standby R -Value System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss (%) Ext. A.O. SMITH 75 GAL Small Gas No Pipe Insulation 1 75,000 75 Altered 0.60 n/a n/a n/a n/a Standard Gas 50 gal or Less Small Gas ore -altered for Aboy 1 40.000 50 0.57 Multi -Family Central Water Heating Details Hot Water Pump Hot Water Piping Len .Control # HP Tvpe In Plenum Outside tl h (ft) Add 1/2" Buried Insulation COMPLIANCE STATEMENT This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them.This certificate has been signed by the individual with overall design responsibility. The undersigned recognizes that compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Name: Title/Firm: Robert A. Pitc Design ing i Address: 77-622Coun& Club Telephone: (sig Enforcement Agency Name: Title/Firm: Address: Telephone: • (signature) (date) Documentation Author Name: Tim Scott Title/Firm: Scott Design & Title 24 Address: 77085 Michigan Dr. alm Desedf CA 92211 Telepho • 60) 2 - 80 l � (signature) (date) w 0 Mandatory Measures Summary: Residential (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Check or initial applicable boxes or check NA if not applicable and included with the ENFORCE - permit application documentation. N/A DESIGNER MENT Building Envelope Measures e§ 150(.): Minimum R-19 in wood ceiling insulation or equivalent U -factor in metal frame ceiling. ❑ K ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value: ❑ ❑ ❑ § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not ❑ ❑X ❑ apply to exterior mass walls). ❑ ❑ ❑ f§ 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent U -factor. ❑ ❑ ❑ § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 1. Masonry and factory -built fireplaces have: 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: a. Losable metal or glass door covering the entire opening of the firebox ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. b. outside air intake with damper and control, flue damper and control ❑ ❑X ❑ 2. No continuous burning gas pilot lights allowed. ❑ indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. ❑ § 150(f): Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual. ❑ ❑ ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. ❑ ❑ ❑ § 150(1): Slab edge insulation - water absorption rate for the insulation alone without facings no greater than 0.3%, water vapor ❑ ❑ ❑ ❑ permeance rate no greater than 2.0 perm/inch. ❑ entirely in conditioned space. § 118: Insulation specified or installed meets insulation installation quality standards. Indicate type and include ❑ ❑ ❑ ❑ CF -6R Form: Page:7 of 17 § 116-17: Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls. 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. ❑ 0 ❑ 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain ❑ ❑ ❑ Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ 0 ❑ Space Conditioning, Water Heating and Plumbing System Measures § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission. ❑ N ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ ❑x ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑ 0 ❑ § 1500): Water system pipe and tank insulation and cooling systems line insulation. 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation ❑ ❑ ❑ having an installed thermal resistance of R-12 or greater. 2. Back-up tanks for solar systems, unfired storage tanks, or other indirect hot water tanks have R-12 external ❑ ❑ ❑ insulation or R-16 internal insulation and indicated on the exterior of the tank showing the R -value. 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire ❑ ❑ ❑ length of recirculating sections of hot water pipes shall be insulated to Table 1508. ❑ ❑ ❑ 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. 4. Steam hydronic heating systems or hot water systems > 15 psi, meet requirements of Table 123-A. ❑ ❑ ❑ 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, ❑ ❑ ❑ and wind. 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed ❑ ❑ ❑ entirely in conditioned space. 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation. ❑ ❑ ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:7 of 17 Mandatory Measures Summary: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance • requirements from the Certificate of Compliance supercede the items marked with an asterisk (') below. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. • DESCRIPTION Instructions: Check or initial applicable boxes when completed or check N/A if not ENFORCE - applicable. NIA DESIGNER MENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) § 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, ❑ ❑X ❑ 605, and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minumum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 1818 or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed ❑ sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive ❑ duct tapes unless such tape is used in combination with mastic and draw bands. 4. Exhaust fan systems have back draft or automatic dampers. ❑ 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operating dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 7. Flexible ducts cannot have porous inner cores. § 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System is installed with: a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. § 115: Gas fired fan -type central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) § 118 (i): Cool Roof material meets specified criteria Lighting Measures § 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballasts for lamps 13 Watts or greater are electric and have an output frequency no less than 20 kHz. § 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast. § 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50% of the Wattage, as determined in Section 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires. § 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires. OR are controlled by an occupant sensors) certfied to comply with Section 119(d). § 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft) OR are controlled by a dimmer switch OR are controlled by an occupant sensor that complies with Section 119(d) that does not turn on automatically or have an always on option. § 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals. § 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d). § 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sections 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Section 130, 131, and 146. § 150(k)8: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by occupant sensor(s) certified to comply with Section 119(d). ❑X ❑ ® ❑ ® ❑ ® ❑ ❑ ❑ ON X ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ® ❑ ❑ ❑ ❑ ❑ a ❑ ❑ a ❑ ❑ ❑X ❑ ❑ a ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ IEnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:8 of 17 Residential Kitchen Lighting Worksheet WS -5R Akr. & Mrs. Lew Price 1/29/2010 oject Title Date At least 50% of the total rated wattage of permanently installed luminaires in kitchens must be in luminaires that are high efficacy luminaires as defined In Table 150-C. Luminaires that are not high efficacy must be switched separately. Kitchen Lighting Schedule. Provide the following information for all luminaires to be installed in kitchens. Luminaire Type High Efficacy? Watts Quantity High Efficacy Watts Other Watts 1 26w Com act Fluorescent Triple 4 Pin Yes X1 No 28.0 x 12 = 336 or Low Voltage Halogen Yes I No IXI 38.0 x 5 = or 190 (1) 2 it Fluorescent T8 Elec Yes X1 No 1 1 22.0 x 3 = 66 or Yes I No I x = or Yes I No I x = or Yes I No I x = or Yes No I x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x = or Yes I No x = or Yes No x = or Yes No x = or Yes No x = or Yes No x - or Yes No x = or • Total A: 402 B: 190 COMPLIES IF A z B YES ® NO ❑ EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page:9 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY 'NAME Mr. & Mrs. Lew Price NAME HVAC 1 Altered Number of Heating Sv Total Output (Btuh) 89,000 Output (Btuh/sqft) 60.3 Cooling System Output per System 59,000 Total Output (Btuh) 59,000 Total Output (Tons) 4.9 Total Output (Btuh/sqft) 40.0 Total Output (sgft/Ton) 300.0 CFM per System Airflow (cfm) Airflow (cfm/sqft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD DATE 1/29/2010 FLOOR AREA 1,475 COIL COOLING PEAK COIL HTG. PEAK CFM I Sensiblel Latent CFM I Sensible 1,548 25,713 146 703 28,388 0 4,574 3,642 0 0 0 0 0 0 0 107.9 of 0 Supply Fan Heating Coil 0 4,574 3,642 34 86 146 F7735 673 Z,Uzo 2,025 Carrier 24ACA460/58CVX110 42,781 8,091 89,000 1.37 411.9 0.0 Total Adjusted System Output 42,781 8,091 89,000 (Adjusted for Peak Design Conditions) 0.00 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 68.3 of 68.3 of 109.6 of ` I Supply Air Ducts Outside Air 0 cfm 107.9 of Supply Fan Heating Coil 2025 cfm ROOMS 70.0 of 68.3 of Return Air Ducts I COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 of 77.1 / 62.4 of 77.1 / 62.5 of 57.3 / 55.2 OF Supply Air Ducts Outside Air 0 cfm Supply Fan Cooling Coil 59.4! 56.0 of 2025 cfm ROOMS 47.4% R.H. 7.1/62.4OF 75.0/61.7OF k Return Air Ducts `S EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 10 of 17 1 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY ROJECT NAME DATE Mr. & Mrs. Lew Price 1/29/2010 YSTEM NAME FLOOR AREA HVAC 2 1,069 Number of Heatinq Sv Total Output (Btuh) Output (Btuh/sgft) Cooling System Output per System Total Output (Btuh) Total Output (Tons) Total Output (Btuh/sqft) Total Output (sgft/Ton) Air System CFM per System Airflow (cfm) Airflow (cfm/sgft) Airflow (cfm/Ton) Outside Air (%) Outside Air (cfm/sgft) Note: values above given at ARI conditions COIL COOLING PEAK COIL HTG. PEAK CFM ISensiblel Latent I CFM Sensible 71,000 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD 71,000 66.4 23,673 46,500 46,500 3.9 43.5 1,307 21,366 216 583 23,673 0 3,801 3,037 0 0 0 0 0 0 0 0 0 3,801 3,037 28,9681 216 29 747 1,600 1,600 Carrier 24ACA448/58CVX090 33,759 6,383 71,000 1.50 412.9 Total Adjusted System Output (Adjusted for Peak Design Conditions) 33,759 6,38371,00010,0100 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26.0 of 68.2 of 109.9 of 109.9 of Outside Air " ;. Supply Air Ducts 0 cfm Heating Coil Supply Fan 108.1 of 1600 cfm ROOMS 70.0 of 68.2 of I Return Air Ducts COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 110.0 / 72.5 of 77.2 / 62.6 of 57.4 / 55.3 of 57.4 / 55.3 of Y `< Supply Air Ducts Outside Air Gw 0 cfm Cooling Coil Supply Fan 59.6 / 56.1 of 1600 cfm 47.5% R.H. ROOMS 7.2/62.5 of 75.0 / 61.8 OF Return Air Ducts I EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 11 of 17 i ROOM LOAD SUMMARY JECT NAME Mr. & Mrs. Lew Price *YSTEM DATE 1/29/2010 NAME HVAC 1 Altered FLOOR AREA 1,475 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Living Zone Altered Living Zone Altered 1 1,548 25,713 146 1,548 25,713 146 703 28,388 PAGE TOTAL 1 1,548 25,713 146 703 28,388 TOTAL 1 1,548 25,713 146 703 28,388 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 12 of 17 4 ROOM LOAD SUMMARY ROJECT NAME Mr. & Mrs. Lew Price DATE 1/29/2010 YSTEM NAME HVAC 2 FLOOR AREA 1,069 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE Sleeping Zone Altered Sleeping Zone Altered 1 1,307 21,366 216 1,307 21,366 216 583 23,673 PAGE TOTAL 1 1,307 21,366 216 583 23673 TOTAL 1 1,307 21,366 216 583 23,673 EnergyPro 4,4 by Energysoft User Number: 6712 Job Number: Page: 13 of 17 ROOM HEATING PEAK LOADS ject Title Date r. & Mrs. Lew Price 11/29/2010 Room Information Desicin Conditions Room Name Living zone Altered Time of Peak Jan 12 am Floor Area 1,475 Outdoor Dry Bulb Temperature 26°F Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1,475.0 X X X x X x X X X X X X X X x X X X X X X X X x X X X X X X X X _ X X X X X X X 0.0350 X X X X X X X X x X x X X X x x X X X X X X X X X X X X X X X X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = = = = = 2,272 128.0 0.3560 44 2,005 24.0 1.4500 44 1,531 230.9 0.1020 44 1,036 32.2 0.3900 44 553 9.4 0.3900 44 161 23.5 0.3900 44 403 285.7 0.3560 44 4,475 52.3 0,3900 44 897 200.2 0.1020 44 898 118.4 0.3900 44=7039 118.4 0.3900 44 2,032 96.0 0.3560 44 1,504 erimeter = 103.0 0.7300 44= 3,308 per6meter=2060 0.7300 44= Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: i 23,7501 Infiltration: r 1.001 X 1.064 X 1 475 X 10.00 X 0.403 / 6] x 44 = 4 638 `schedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 28,388 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 14 of 17 ROOM HEATING PEAK LOADS 4Fir.Title Date Fr. & Mrs. Lew Price 11/29/2010 Room Information Desi n Conditions Room Name Sleeping Zone Time of Peak Jan 12 am Floor Area A1ed98 Outdoor Dry Bulb Temperature 26OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value AT of Btu/hr 1,460.0 X X x X X x x X X X X x x X x X X x X X X x X X X x X X X X X X X x X X X X X 0.0350 X X x x X x x X X X x x X x x X x X X x x X X x X X X x x X x X X X X X X X X 44 = = = = = = = = = = = = = = = = = = = = = = = 2,248 136.0 0.3560 44 2,130 110.0 0.3560 44 1,723 9.0 0.3900 44 154 9.0 0.3900 44 154 24.6 0.1020 44 110 80.4 0.3900 44 1,380 85.0 0.3566 44 1,331 385.7 6 3560 44 &042 9.0 0.3900 44 154 9.0 0.3900 44=154 8.0 0.3900 44 137 52.3 0.3900 44 897 perimeter = 80.0 0.7300 44= 2,570 perimeter = 35.0 0.7300 44=11124 Items shown with an asterisk (f') denote conduction through an interior surface to another room. Page Total: I 20,311 Infiltration: I1 1.001 x 1.064 x 1 069 x 10.00 x 0.403 / 60] x 44 = 3 361 chedule Air Sensible Area Ceiling Height ACH OT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 23,673 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 15 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Wiect Title Date r. & Mrs. Lew Price 11/29/2010 Room Information Desi n Conditions Room Name: Living Zone Altered Outdoor Dry Bulb Temperature: 111OF Floor Area: 1,475 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75OFOutdoor Daily Range: 340F • Opaque Surfaces R-13 Wall W.13.2x4.16 Default Wall Prior to 1978 R-13 Wall .13.2x4.16 Default Wall Prior to 1978 Orientation Area X X X X X X X x x x x x U -Factor X X x X X X X x x x x x CLTD 1 = = = = = = = = = = = = N 1,475.0 0.0350 56.0 N 128.0 0.3560 26.6 N 24.0 1.4500 26.6 N 230.9 0.1020 26.6 E 285.7 0.3560 31.7 S 200.2 0.1020 27.7 (W) 96.0 0.3560 32.3 S 0.0 21.6 118.4 24.5 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration 4 Window Altered Window Window Window Altered Window Window rage I otal Orientation Shaded Area X x X x x x X GLF + + + + + + + Unshaded Area X X X X X X X Page GLF = = = = = = N 0.0x 21.6+ 32.2X 25.6= N 0.0 21.6 9.4 25.6 N 0.0x 21.6+ 23.5X 25.6= E 0.0x 21.6+ 52.3X 40.3= S 0.0X 21.6+ 118.4X 24.5= S 0.0 21.6 118.4 24.5 Total Btu/hr Btu/hr Internal Gain Btu/hr Occu ants 2 Occupants x 230 Btuh/oCC. = 460 E ui ment B Dwelling Units X 1,600l Btuh = 1,6001 Infiltration: 1.064 x 0.88 X 104.08 X = 3.5241 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,713 Latent Gain Btu/hr Occu ants F772 'Occupants X 1 200 Btuh/oCC. = 400 Infiltration: 4 771 x 0.88 X 104.08 X 0.00058 = -254 • Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 146 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 16 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY oject Title Date r. & Mrs. Lew Price 1/29/2010 Room Information Design Conditions Room Name: Sleeping Zone Altered Outdoor Dry Bulb Temperature: 111OF Floor Area: 1,069 sf Outdoor Web Bulb Temperature: 730F Indoor Dry Bulb Temperature: 75OFOutdoor Daily Range: 340F • upaque burraces R-30 Roof(R.30.2x12.16) IDefault Wall Prior to 1978 1 Default Wall Prior to 1978 Default Wall Prior to 1978 Orientation Area X X X X X X X X X X x x U -Factor X X X X X X X X X x x X CLTD 1 = = = = = = = = = = N 1,460.0 0.0350 56.0 N 136.0 0.3560 26.6 E 110.0 0.3560 31.7 S 24.6 0.1020 27.7 S 85.0 0.3560 27.7 W 385.71 0.3560 32.3 0.0X 21.6+ 9.0X 42.4= W 0.0 21.6 8.0 42.4 W 0.0x 21.6+ 52.3X 42.4= Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Fenestration rage I otai Orientation Shaded Area X x X X X X GLF + + + + + + Unshaded Area X X X X X X Page GLF = = = = E 0.0x 21.6+ 9.0x 40.3= E 0.0x 21.6+ 9.0x 40.3= S 0.0 21.6 80.4 24.5 W 0.0x 21.6+ 9.0x 42.4= 0.0X 21.6+ 9.0X 42.4= W 0.0 21.6 8.0 42.4 W 0.0x 21.6+ 52.3X 42.4= Total Btu/hr 2,862 1,288 1,240 69 837 4,440 10 736 Btu/hr Internal Gain Btu/hr Occu ants 2 Occupants X 230 Btuh/oCC. = 460 E ui ment 111 Dwelling Units X 1,6001 Btuh = 1,6001 Infiltration: 1.064 X 0.88 X 75.43 X = 2.5-9;4 Air Sensible CFM ELA DT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 21,366 Latent Gain Btu/hr Occu ants 0 Occupants X I Btuh/OCC. = 400 Infiltration: 4 771 x 0.88 x 75.43 x 0.00058 = -184 Air Latent CFM ELA pW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 216 EnergyPro 4.4 by EnergySoft User Number: 6712 Job Number: Page: 17 of 17