Loading...
0206-189 (RR)LICENSED CONTRACTOR DECLARATION I heftby•affird under penalty of perjury that I am licensed under provisions of .,Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License # Lic. Class Exp. Date 3£851.1S C39 CS'P30ls� a e� b Zi. n ture of Contractor —� Sg a OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason: ( ) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec, 7044, Business & Professionals Code). ( ) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business & Professionals Code). () I am exempt under Section , B&P.C. for this reason Date "' Signature of Owner WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ( ) I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the per?rsnance of the work for which this permit is issued. ( have and will maintain workers' compensation insurance, as required by Sec n 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier & policy no. are: Carrier " 13hjp<1 Policy No. (This section need not be completed if the permit valuation is for $100.00 or less). ( ) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of Califg�nia, and agree that if I should become subject to the workers' compensatioli provisions of Secti 37 rohttie Labor Code, I sGlall prt w th comply with those 'r vI Ions f Date: 7 1 Applicant t Warning: Failure to secure Workers' Compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to $100,000, in addition t4 the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on his application. 1. Each person upon whose behalf this application -is made & each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this applicaton agrees to, & shall, indemnify & hold harmless the City of La Quinta, its officers, agents and employees. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply witr all City, and State laws relating to the building construction, and hereby auf ri •e representatives of this City to enter upon the above-mentioned property` f • r�n p°qection pur oses. ,urn• Ph, Signature (Owner/Agent)f? Date BUILDING PERMIT PERMIT# DATE VALUATION LOT �� TRACT "� + /J + .. JOB SITE 1 ADDRESS =_NT -J r-- APN OWNER t CONTRACTOR / DESIGNER / EN (NEER C' Fl MIES YX 11, 00T.E FtCjMANO Co.. 49=7.96 C°OAG`HIELLAAMCTE, 65-947 CAHMA. LA,QiWA Citi 92253 :l���:�;SrrS5.I,��Rryryigg"•�Hffryry((T%.��'i„NG CA 97,240 USE OF PERMIT .$MTEPAL BIM— 3I'O R?iMOii'.IDMKISa`Y.*NQWOOP SH[14 1,f; ttOC FIREPL.A.C:Ir'Er�A�,4, S'l'RUC.`.1 URA); P'ALC, {CWW ".Aa .KIRK RATINSO RE:QlfIRP On A CITYOFLAQUINTA FINANCE DEPT X811WIMID COW Or CONSIFMCTION r OOF YZE 1(9? 400418-000LESS PRE -PAW FE&I saob rJXxr§,D-0:K Now ' r RECEIPT DATE ;? �✓'a �t uBY,:f_DATE FIN ED INSPECTO ' INSPECTION RECORD OPERATION DATE INSPECTOR OPERATION DATE INSPECTOR BUILDING APPROVALS MECHANICAL APPROVALS Set Backs Underground Ducts - Forms & Footings Ducts Slab Grade Return Air Steel Combustion Air Roof Deck Exhaust Fans O.K to Wrap F.A.U. Framing Compressor Insulation Vents Fireplace P.L. _ _ _ Grills Fireplace T.O. Fans & Controls Party Wall Insulation Condensate Lines Party Wall Firewall Exterior Lath Drywall - Int. Lath _ Final p_Z25--�5 f BLOCKWALL AP. ROVALS Final POOLS -SPAS Steel Set Backs Electric Bond Footings Main Drain Bond Beam Approval to Cover Equipment Location Underground Electric Underground Plbg. Test Final Gas Piping PLUMBING APPROVALS Gas Test Electric Final Waste Lines Heater Final Water Piping Plumbing Final Plumbing Top Out Equipment Enclosure Shower Pans O.K. for Finish Plaster Sewer Lateral Pool Cover Sewer Connection Encapsulation Gas Piping Gas Test Appliances Final Final Utility Notice (Gas) ELECTRICAL APPROVALS Temp. Power Pole Underground Conduit Rough Wiring Low Voltage Wiring Fixtures Main Service Sub Panels Exterior Receptacles G.F.I. Smoke Detectors Temp. Use of Power Final Utility Notice (Perm) COMMENTS: Alcumbrac W- Architects October 4, 2001 City of La Quinta Department of Building and Safety Hand Delivered by Contractor P. U 13ax 473 - Thousand Palms, CA 92276 Phone (760) 343-0048 fax ,(760) 343-3637 REROOFING CERTIFICATION 49-796 COACHELLA DR. As a Registered Architect, Licensed to practice in the State of California, I have reviewed plans submitted by the Owner and his selected Contractor for compliance to support reroofing as per the attached calculations. Roof Slope is 3.25/12. Controlling spans on 6x8 members are limited to 16'. Laminated Beams have a controlling span of 20' and are adequately sized. The roof structure per submitted plans and specifications is capable of tile reroofing not to exceed a weight of 13 psf. Refer to attached calculation with tile weight @ 12 psf as adequate. As submitted to me this roof structure will meet the requirements of the 1997 Uniform Building Code for life safety criteria a defined," but not specific property protection or preventive building damage. " G Respectfully submitted: Robert S 4n Alcumbrac NO. C-10381 Robert S. Alcumbrac s� R\ SOF CA�\F�Q o r (CIt, C o CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DA b Y °L BY .M- -� Roof Beamr 97 UBC (91 NDS)1 StruCalc 4.06 {- Bv: Robert Alcumbrac. Alcumbrac Architects on: 10.03.2001 Proiect: OVERSTAC • Location: 49.796 COACHELLA DR. Summarv: 5.50 IN x 7.50 IN x 16.0 FT (Actual 16.919 FT) / #1 - DOUGLAS FIR -LARCH - Dry Use Section Adequate By: 6.5% Controlling Factor: Section Modulus / Depth Required 7.27 Ir Deflections: Dead Load: DLD= 0.48 Live Load: LLD= 0.45 Total Load: TLD= 0.93 Reactions (Each End): Live Load: RL= 640 Dead Load: RD= 677 Total Load: RT= 1317 Bearing Length Reqd.: BL= 0.38 Beam Data: Span: L= 16.0 Maximum Unbraced Soan: Lu= 0.0 Beam End Elevation Diff.: EL= 5.5 Pitch Of Roof: RP= 3.25 Live Load Deflect. Criteria: L/ 240 Total Load Deflect. Criteria: L/ 180 Beam Loading: Live Load: LL= 20 Roof Loaded Area: RLA= 64 Roof Live Load Method: 1 Side One: Roof Dead Load: DLI= 18 Roof Rafter Tributary Width: � TW1= 2.0 Side Two: Roof Dead Load: DL2= 18 Roof Rafter Tributary Width: 7W2= 2.0 Roof Duration Factor: Cd= 1.15 Slope Adiusted Lengths and Loads: Adiusted Beam Length: Ladi= 16.919 Beam Live Load W/ Slope Red'n: wL= 76 Beam Self Weight: BSW= 9 Beam Total Dead Load: wD= 80 Total Maximum Load: wT= 156 Controlling Total Design Load: wTcont= 156 Properties For: #1- DOUGLAS FIR -LARCH Bending Stress: Fb= 1200 Shear Stress: Fv= 85 Modulus of Elasticitv: E= 1600000 Stress Perpendicular to Grain: Fc_perp=. 625 Adjusted Properties: Fb' (Tension): Fb'= 1380 Adjustment Factors: Cd=1.15 Cf=1.00 Fv': Adiustment Factors: Cd=1.15 Design Reauirements: Maximum Moment: Shear ((@ d from beam end): Comparisons With Reauired Sections: Section Modulus: Area: Moment of Inertia: T1 Yom''• i -Irk) = IN IN = L/426 IN = L/207 LB LB LB IN FT FT FT : 12 PSF SF PSF FT PSF FT FT PLF PLF PLF PLF PLF PSI PSI PSI PSI PSI Fv'= 98 PSI M= 5570 FT -LB V= 1220 LB Srea= 48.5 IN3 S= 51.5 IN3 Area=18.8 IN2 A= 41.2 IN2 Irea= 159.1 IN4 1= 193.3 IN4 t:Y OF IA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE_ -BY 4FOOTE ROOFING NO. 785158 JUNE 20, 2002 CO. CLARK HUBBS JR. 601 W. 5TH ST. SUITE 755 LOS ANGLES., -CA 90071 RE: TILE REROOFING PROPOSAL Residential • Commercial • Re -Roofing 65-947 Cahuila Ave. • Desert Hot Springs, CA 92240 • 760-288-3207 JOB ADDRESS: 49-796 COACHELLA DR. LA QUINTA, CA 92253 EXISTING ROOF. 2. TEAR OFF EXISTING WOOD SHINGLE ROOF DOWN TO WOOD SHEATHING. ` 3. REPLACE FASCIA OR SHEATHING BOARDS AT AN ADDITIONAL CHARGE OF $6.00 PER LIN. FT. AS NECESSARY. 4. INSTALLATION OF NEW ROOFING SYSTEM TO MEET OR EXCEED UNIFORM BUILDING_ CODE(UBC) TABLE 15=D-2, AND ROOF TILE INSTITUTE(RTI)/ WESTERN STATES ROOFING CONTRACTORS _ASSOCIATION(WSRCA) RECOMMENDATIONS IN CONCRETE AND CLAY ROOF TILE DESIGN CRITERIA INSTALLATION MANUAL FOR MODERATE CLIMATE REGIONS(JANUARY 1ST, 2002 EDITION) ON ALL APPLICABLE REQUIREMENTS. 5. INSTALL TWO(2) LAYERS OF 40# ORGANIC FELT UNDERLAYMENT (EXCEEDS ASTM D226). , 6. INSTALL ONE(1) LAYER OF GRACE OR EQUAL OF BITUETHENE SELF ADHERED FLASHING MEMBRANE (ALSO KNOWN AS STORMGUARD OR ICESHEILD), DIRECTLY OVER NEW SHEATHING AS A "BLEEDER STRIP" TO VALLEY AREAS. 7. INSTALL GALVANIZED VALLEY.METAL IN VALLEY AREAS. 8. INSTALL BROWN METAL DRIP EDGE AT EAVES WITH 1" FACE. 9. INSTALL NEW VENT AND PIPE FLASHING, BOTH GALVANIZED PRIMARY, AND GALVANIZED SECONDARY 10. INSTALL RELATED SHEETMETAL (I.E. ROOF TO WALL, TILE PAN AND CHIMNEY SADDLE METAL) AS NEEDED. -ii. COVER PROJECTOR ON ROOF 12. INSTALL.WOOD NAILERS AT RIDGES, WRAP WITH UNDERLAYMENT. 13. INSTALL HANSEN TILE # WES 557 TWO(2) COLOR SHAKE BLEND CONCRETE TILE (ASTM C1492) AT A RATIO OF: 50/ 1 OF 2, AND 50/ 2 OF 2 OVER NEW UNDERLAYMENT PER MANUFACTURERS RECOMMENDATIONS 14. INSTALL TILE WITH DOUBLE FIRST COURSE (SEE ADDENDUM A). 15. INSTALL MATCHING HANSEN #557 TRIM TILES, BOTH RAKE AND RIDGE 16. APPLY MORTAR (CEMENT) AT HIP AND GABLE ENDS. 17. SEAL AND PAINT ALL VENTS AND PIPES. It is agreed that this job has been estimated from plans and the building is constructed larger than the plans show, this contractor will be paid for the extra r. labor and material. Quotations herein are subject to change without notice prior to the time of acceptance by both parties. A No terms, conditiohs or agreements have been -made by either of the parties hereto except as contalned herein or endorsed hereon. We will not be responsible for delays beyond our control. This estimate becomes a contract when and only when, signed by both parfles hereto. Should either party hereto bring suit in court to enforce the terms hereof, any judgement awarded shall Include court costs and reasonable attorney's fees to the successful party. THE PARTIES HERETO HAVE EXECUTED THIS AGREEMENT THE t 'DAY OF 2002 FOOTE ROOFING CO. ate Lie nse # 785158 THE SELLER V J THE BUYER FooTE ROOFING CO. NO. 785158 JUNE 20, 2002 CLARK HUBB JR. PROPOSAL Residential • Commercial • Re -Roofing 65-947 Cahuila Ave, • Desert Hot Springs, CA 92240 • 760-288-3207 JOB ADDRESS: RE: TILE REROOFING CONTINUE FROM PAGE 1 18. CLEAN AND INSPECT FLAT ROOF. 19. MAKE ANY NECESSARY REPAIRS. 20. APPLY TWO (2) LAYERS OF HENRYS' #287 OR EQUAL OF ELASTOMERIC ROOF COATING AT A RATE OF 1.5 GALLONS PER 100 SQ. FT. PER LAYER FOR A TOTAL OF 3 GALLONS PER 100 SQ. FT. 21. MAINTAIN JOB -SITE IN AN ORDERLY MANNER. 22. PROVIDE PROOF OF WORKER'S COMP.,.AND $1,000,000 LIABILITY INS. UPON REQUEST. 23. OBTAIN ALL NECESSARY PERMITS. 24. REMOVE ALL ROOFING DEBRIS FROM PREMISES. ROOFING CARRIES A TEN(10) YEAR WARRANTY FROM FOOTE ROOFING CO -(SEE ADDENDUM B) MATERIAL WARRANTY IS FROM THE MANUFACTURER. WORK TO BEGIN ON JUNE 21ST, 2002 AND BE COMPLETED BY JULY 12TH, 2002. COMPLETE.......................$11,500.00 PAYMENT SCHEDULE: HOMEOWNER TO PAY ROOFING WHOLESALE INC. FOR MATERIALS ON 6/18/02. TOTAL ........... $5689.37 50% OF REMAINING BALANCES ARE DUE WHEN UNDERLAYMENT INSTALLATION IS COMPLETE AND TILES ARE LOADED ON ROOF. TOTAL ........... $2905.32 FINAL PAYMENT IS DUE WHEN ROOF IS COMPLETE TO SATISFACTION OF HOMEOWNER. TOTAL ........... $2905.32 It is agreed that this job has been estimated from plans and the building Is constructed larger than the plans show, this contractor will be paid fob tpe extra labor and material. Quotations herein are subject to change without notice prior to the time of acceptance by both parties. No terms, conditions or agreements have been made by either of the parties hereto except as contained herein or endorsed hereon. We will not be responsible for delays beyond our control. This estimate becomes a contract when and only when, signed by both parties hereto. Should either party hereto bring suit in court to enforce the terms hereof, any judgement awarded shall Include court costs and reasonable attorneys fees to the successful. party. t S -T THE PARTIES HERETO HAVE EXECUTED THIS AGREEMENT THE DAY OF 205—L FOOTE ROOFING CO. to Li nse # 785158 THE SELLER vH BWE Is