Loading...
10-1114 (RER)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 T-dif " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 10-00001114 Property Address: 49826 COACHELLA DR APN: 646-250-013-13 -4275 - Application description: REMODEL - RESIDENTIAL Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 2500 Applicant: Architect or Engineer: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that.) am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1'_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_ 1 I am exempt under Sec. , B&C. for this reason Date'a�/ D Owner: I hereby affirm under penalty of perjury that there is a construction IdQOng agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: OWEN P JOHN Contractor: Owner IIU VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 11/05/10 e NOV 10 2010 D OF LA WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. _ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I sh com subject to the wort rs' compensation provisions of Section 3700 of [he Lab e, all th 'th com I Ni those pro isi S. r Date: IN , 1 ®r/ O Applicant: WARNING:: FAILURE TO SECU E WOR RS' COMPENSATION COFSFIAGTEAUNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TOC (MIN PENALTIES AND CIVIL FIO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADD( TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. . APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the appticant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. ' 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above'nfor ation is correct. I ag to comply with all city and county ordinances and state laws relating to building c stru 'on, and hereby au rize r p e t 'ves of this county to enter upon the above-mentioned pro i Date: I/ to r�61Signature (Applicant or Agent): Application Number . .. . . . 10-00001114 ------ Structure Information WINDOW CHANGE OUT AT REAR ELEVATION ----- Other struct info . . . . . CODE EDITION ------------------------=--------------------------------------------------- 2007/2008 Permit . . . BUILDING PERMIT Additional desc . Permit'Fee 54.00 Plan Check Fee 35.10 Issue Date Valuation . . . 2500 Expiration Date.. 5/04/11 Qty Unit Charge Per Extension BASE FEE 45.00 1.00 9.0000 THOU BLDG 2,001-25,000 ---------------------------------------------------------------------------- 9.00 . Permit .. . . ELECT,- ADD/ALT/REM Additional desc . Permit Fee 16.50 Plan Check Fee 4.13 Issue Date . . . . Valuation . . . . 0 Expiration Date 5/04/11. Qty' Unit Charge Per Extension BASE FEE 15.00 2.00 ..7500 PER ELEC DEVICE/FIXTURE 1ST 20 ---------------------------------------------------------------------------- 1.50 Special Notes and Comments (2) SLIDING GLASS DOORS & (1) WINDOW CHANGE -OUT AT REAR ELEVATION + LIGHT AND SWITCH AT NEW DOOR LOCATION. 2007/2008 CALIFORNIA BUILDING CODES. November 5, 2010 11:55:58 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid Credited ------ - --- ---------- ---------- Due. ---------- ----------------- Permit Fee Total 70.50 .00 .00 70.50 Plan Check Total 39.23 .00 .00 3.9.23 Other Fee Total 1.00 .00 .00 1.00 Grand Total 110.73 .00 .00 110.73 LQPERMIT Oa V.. Pis k� P.O. BOX 1504 LA QUINTA; CALIFORNIA 92247-1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT PROPERTY OVM- ER' S PACKAGE (760) 777-7012 FAX (760) 777-7011 Disclosures & Forms for Owner-$.utIflers Applying for Constntction Permits `'1 KOWE TSD PROPIK TY OMR Dear Property Owner. An. application .for a building permit has been submitted in your name listirrg yourself as the builder of the progorty improvements specified at We are pmViding yroti W'W an Owner-]Budder'Ackit4wtedgine nt.aiid [tiformation Vecificatidii Foram to ice you a*= of your responsibilities and possible -risk you may incur by halviag this permit issued in your mme as the Owe -Builder. We wilt not issue a builElin ,n. >.A� .bs rQ {glde And oL signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. 0WWsa c» T A ® 1 A' lrl DAVEMM S: Read Md w aiat eachstatement below m sign#y you araferst nd or vet* this inP,madOn. I. I understand .a frequent practice of unlicensed persons is to have the property owner obtain an "Owner -Builder" building permit that erroneously implies that the property owner is providing hisor her own labor and material personally. I, as an Owner -Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner -Builder and am aware of the limits of my insurance.coverage for injuries to workers on my. propesty. 2. 1 understand building permits are not required to be signed by property owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. I understand as an "Owner -Builder" I am the responsible party of record on the permit I understand that I may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. — 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers -on permits and contracts. 5. I understand if I employ or otherwise engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars' ($500), including labor and. materials, I may be considered an "employer" under state and federal law. 6. I understand if I am considered an -employee, under state and federal law, I- must register with the state and federal government, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. 7. I understand under California Contractors' State License Law, an Owner -Builder who builds single-family residentii structures cannot .legally build them with the . intent to offer them for sale, unless all work is performed by licensee subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performem under contract with a licensed general building Contractor. 8. I understand as an Owner -Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal. 4ades sustained by any subsequent owner(s) that result from any latent construction defects in the workmanship or materials. 9. 1 understand I may obtain more information regarding my obligations as an "employer" from the Internal R®Wuue Service, the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Induistrial Accidents. I also understand I may contact the California Contractors' State License Board (CMB) at 1- 800-321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 10. I am aware of and consent to an Owner -Builder building permit applied for in my name, and understand that I am the party legally and financially respons for proposed construction activity at the following address: 1 L I. agree that, as the party legally and financially responsible for this proposed construction activity, l will abide by all applicabte laws and requirements that govemi Owner-luuilders as well as employers. 12. 1 agree to notify the issuer of this form immediately of any additions; deletions, or chaff W aMy of the i nfarmatton I have provided on this form. Licensed contractors are regulated by taws designed to protect the public. if YOU contract with someone who does not have a Iiunse,. Bre Contractors' State LiOMW Boaml may be unable to assist'you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in'civil count It is also important for you to undersumd that if an udUoensed Contractor or employee of that individual or i� is Wjuted while vF 0ddng on your property; you may. be held MW for damages. If you obtain a permit as Owner -Builder and wish to hire Conttvietors, You will be r$soonsMe for vertjda B edam o nw -t = Contra_ VVedW cen and An staWs of MY w0titers' Compensationmxuanw coverage. Before a building permit can be issued, this form must be completed attd silgp W by the property owner and returned to go e agency responsible for issa#ug prp.ruiit. N:��copp Bf' a nfr riv tirivr Bt�ter voua�p'�ta4"tte�'p, A-W,_IKerW_M;_ ON, aratier's stghe. ' % tJ is property ownerAL -p�'/ Note: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner -Builder. AUTHORIZATION OF AGMT TO ACT ON rROPERTY OWNEWS MRHA� Excluding the Notice to Property Owner, the execution of which I understand is my personal r-mponsibility, I hereby authorize the following persons} to act as my agent(s). to apply for, sign, and file the documents necessary to obtain anOwner-Builder Permit for'my project. Scope of. Construction Project (or Descriptioaaf Worlr):. Project Location or Address - e? _:uy Name of Authorized Agent: 02 Yt -A " e / `r u 1 Tel No Address of Authorized Agent: - I declare under penalty of perjury that I am the property owner for the address listed above and I personally fulled out the above information and certify its accuracy. Note: A copy of the owner's driver's license, form notarization, or other verification acceptable to. the agency is required'to be presented when the permit is issued to verify the property owner's signature.. r - Property Owneft;i$nattud: B`" # 410- City of La Quinta Building eX Safety Division P.Q. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Addres Owner's Name: <f)NVV-0 A. P. Number: Address: 6C iwyG6 \ � Legal Description: Ln7- City, ST, Zip: rC�Ci C Contractor: lL Telephone: - Address: Project Description: City, ST, Zip:Vj Q, Telephone: � State Lie. # : City Lie. #:%� Com( , Designer: r7 ��t 'CG4fz* Address: -7 % —� Z Z C-CiC . City, ST, Zip: 22-1Telephone: 774 t� 7j State Lie. #: Construction Type: Occupancy: Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: LE�brj Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: -7�0 Estimated Value of Project: Z S��b o APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Reed TRACKING PERMIT FEES Plan Sets Plan Check submitted I Item Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cales. Plans picked up Construction �V Flood plain plan Plans resubmitted Mechanical �- Grading plan 2" Review, ready for eorrectionsfasue Electrical y,4 • Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. .-- H.O.A. Approval Plans resubmitted Grading r IN HOUSE:- "' Review, ready for correclionsressue Developer Impact Fee ^ Planning Approval Called Contact Person .I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total Permit Fees 1I 151 W - 0;0*f 15 I up* Co 1WM !- BUILDING ENERGY ANALYSIS REPORT PROJECT: John Owen Alteration 49-826 Coachella La Quinta, CA 92253 Project Designer: Robert A. Pitchford, Design and Drafting 77-622 Country Club, Suite O Palm Desert, CA 92211 (760) 346-2856 Report Prepared by: Tim Scott Scott Design and Title 24, Inc, 77-085 Michigan Drive Palm Desert, Ca 92211 (760).200-4780 CITY OF , LA QUINTA BUILDING & SAFETY DEPT. APPROVED Job Number: FOR CONSTRUCTION ro Date: OCT 2 7 0& 10/22/2010 BY: The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. r: 0 • I TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC System Heating and Cooling Loads Summary 11 Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 I EnergyPro 5.1 by EnergySoft Job Number. ID: User Number. 6712 • • • PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name John Owen Alteration Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration 11012212010 Date Project Address 49-826 Coachella La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 2,682 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ❑ Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity (ft) Features see Part 2 of 5 Status Roof Wood Framed Attic R-30 2,682 Existing Wall Wood Framed R-11 1,691 Existing Slab Unheated Slab -on -Grade None 2,682 Perim = 221' Existing FENESTRATION U- Exterior Orientation Area(ft) Factor SHGC Overhang Sidefins Shades Status Rear (N) 240.0 0.400 0.35 none none Bug Screen Altered Right (E) 20.0 0.400 0.35 none none Bug Screen New Right (E) 28.0 0.710 0.73 none none Bug Screen Existing Front (S) 66.4 0.710 0.73 none none Bug Screen Existing Left (W) 20.0 0.710 0.73 none none Bug Screen Existing HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback , Existing HVAC DISTRIBUTION Duct Location Heating Cooling Duct Location R -Value Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING (fit . Type Gallons Min. Eff Distribution Status EnergyPro 5. 1 by EnergySoft User Number: 6712 RunCode: 2010-10-22714:54:15 ID: Page 3 of 15 • • • PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R Project Name John Owen Alteration Building Type m Single Family ❑ Addition Alone 1 ❑ Multi Family ® Existing+ Addition/Alteration Date 11012212010 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemvPro 5.1 by EnemySoft User Number: 6712 Run Code: 2010-10-22714:54:15 ID: Page 4 of 15 • • • PERFORMANCE CERTIFICATE: Residential Part 3 of 5 CF -1 R Project Name Building Type m Single Family ❑ Addition Alone Date John Owen Alteration 1 ❑ Multi Family m Existing+ Addition/Alteration 1101221201C ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 7.81 7.17 0.64 Space Cooling 114.63 104.47 10.16 Fans 21.89 19.97 1.92 Domestic Hot Water 13.60 13.60 0.00 Pumps 0.00 0.00 0.00 Totals 157.93 145.21 12.72 Percent Better Than Standard: 8.1% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 488 66 Fuel Available at Site: Natural Gas (w) 522 20 Raised Floor Area: 0 (N) 504 240 Slab on Grade Area: 2,682 (E) 551 48 Average Ceiling Height: 9.5 Roof 2,682 0 Fenestration Average U -Factor: 0.49 TOTAL: 374 Average SHGC: 0.47 Fenestration/CFA Ratio: 14.0% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and compl te. Documentation Author Company Scott Design and Title 24, Inc, 10/22/2010 Address 77-085 Michigan Drive Name Tim Scott City/State/ZipCity/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford, Design and Drafting Address 77-622 Country Club, Suite O Name Robert A. Pitchford L City/State/Zip Palm Desert, CA 92211 Phone (760) 346-2856 Signed Licen e # Date Ene Pro 5. 1 by EnemySoft User Number: 6712 RunCode: 2010-10-22T14:54:15 /D: Page 5 of 15 • • • CERTIFICATE OF COMPLIANCE: Residential Part 4 of 5 CF -1 R Project Name John Owen Alteration Building Type m Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 0/22/201 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Factor Cavi!Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments Roof 2,682 0.031 R-30 0 0 Existing 4.2.1-A20 Alteration Wall 264 0.110 R-11 0 90 Existing 4.3.1-A2 Alteration Wall 503 0.110 R-11 90 90 Existing 4.3.1-A2 Alteration Wall 422 0.110 R-11 180 90 Existing 4.3.1-A2 Alteration Wall 5021 0.110 R-11 270 90 1 Existing 4.3.1-A2 Alteration Slab 2,682 0.730 None 0 180 Existing 4.4.7-A1 Alteration FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 80.0 0.400 NFRC 0.35 NFRC 0 Altered Double Non Metal Tinted Alteration 2 Existing 0.710 Default 0.73 Default Double Metal Clear pre -altered for above 3 Window 80.0 0.400 NFRC 0.35 NFRC 0 Altered Double Non Metal Tinted Alteration 4 Existing 0.400 NFRC 0.35 NFRC Double Non Metal Tinted pre -altered for above 5 Window 80.0 0.400 NFRC 0.35 NFRC 0 Altered Double Non Metal Tinted Alteration 6 Existing 0.710 Default 0.73 Default Double Metal Clear pre -altered for above 7 Window 20.0 0.710 Default 0.73 Default 90 Removed Double Metal Clear Alteration 8 Window 20.0 0.400 NFRC 0.35 NFRC 90 New Double Non Metal Tinted Alteration 9 Window 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Alteration 10 Window 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Alteration 11 Window 20.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Alteration 12 Window 23.2 0.710 Default 0.73 Default 180 Existing Double Metal Clear Alteration 13 Window 1 20.0 0.710 Default 0.73 1 Default 180 Existing Double Metal Clear Alteration 14 Window 23.2 0.710 Default 0.73 Default 180 Existing Double Metal Clear Alteration 15 Window 20.0 0.710 Default 0.73 1 Default 270 Existing Double Metal Clear Alteration (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-13 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window H t Wd Ove hanq Left Fin Len H t LExt RExt Dist Len Right Fin H t Dist Len H t 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Buq Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen 0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010-10-22T14:54:15 ID: Page 6 of 15 • �J C] CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5 CF -1 R Project Name John Owen Alteration Building Type ® Single Family ❑ Addition Alone ❑ Multi Family m Existing+ Addition/Alteration Date 10/22/201 BUILDING ZONE INFORMATION System Name Zone Name New Floor Area Existinq Altered Removed Volume Year Built HVAC -1 Alteration 2,682 25,479 1980 Totals 01 Z6821 01 0 HVAC SYSTEMS System Name Q Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC -1 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heatind Cooling Duct Duct Location R -Value Ducts Tested? Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 ❑ Existing WATER HEATING SYSTEMS S stem Name at . Type Distribution Rated Input Btuh Tank Cap. al Energy Standby Factor Loss or or RE Pilot Ext. Tank Insul. R- Value Status Existing DWH 1 Small Gas Kitchen Pipe Ins 40,000 50 0.57 n/a na Existing MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control E 7 E lv w o_ Hot Water Piping Length (ft)o v Q — ' System Name Pipe Length Pipe Diameter Insul. Thick. Qt . HP Plenum Outside Buried ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ EnemyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2010-10-22714:54:15 ID: Pae 7 of 15 C c MANDATORY MEASURES SUMMARY: Residential Pae 1 of 3 MF -1 R Project Name John Owen Alteration Date 11012212010 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: 116 (a)1: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(1): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(1) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50 a : Minimum R-19 insulation in wood -frame ceiling orequivalent U -factor. 150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent U -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor orequivalent U -factor. 150(f): Air retarding wrap is tested, labeled, and installed according to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: 150 a 1A: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire openinq of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is eq ui ed with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. 150(h): Heating and/or cooling loads are calculated in accordance with ASH RAE, SMACNA or ACCA. §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 123-A. 150(50(NA: Insulation is protected from damage, including that due to sunlight, moisture equipment maintenance and wind. §1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1500)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoff User Number., 6712 Run Code: 2010.10-22T14:54:15 ID: Page 8 of 15 4 ANDATORY MEASURES SUMMARY: Residential Pa e 2 of 3 MF -1 R oject Name rr Date hnn Owen Alteration 11012212010 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. 150(m)7: Exhaust fans stems have back draft or automatic dampers. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or ro rammed to run only during off-peak electric demand periods. §150(p): Residential pool systems orequipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150(p). Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low eff icacy luminaire asspecified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a medium screw -base socket. 150(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). 150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoff User Number. 6712 RunCode: 2010-10-22T14:54:15 ID: Page 9 of 15 4 4 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date ohn Owen Alteration 11012212010 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)12: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housin and ceiling. §150(k)13: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)l4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131 134 and 146. §150(k)l6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2010.10-22714:54:15 ID: Page 10 of 15 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name John Owen Alteration Date 10/22/2010 System Name HVAC -1 Floor Area 2,682 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK CFM Sensible Total Room Loads 1,452 30,588 Return Vented Lighting 0 Return Air Ducts 2,594 Return Fan 01 Ventilation 0 0 Supply Fan 0 Supply Air Ducts 2,594 TOTAL SYSTEM LOAD 1 35,776 COIL HTG. Latent CFM 2,695 787 01 0 2,695 PEAK Heating System Sensible Output er S stem 75,000 34,490 Total Output Stuh 75,000 Output Btuh/s ft 28.0 2,450 Cooling System 0 Output per System 48,000 0 Total Output Stuh 48,000 0 Total Output ons 4.0 2,450 Total Output Stuh/s ft 17.9 Total Output s ft/Ton 670.5 39,391 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow cfm 1,600 Existing System 38,887 3,202 75,000 Airflow cfm/s ft 0.60 75,000 F Jan 1 AM Airflow cfm/Ton 400.0 Outside Air % 0.0% Total Adjusted System Output 38,887 (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 3,202 Aug 3P MI Outside Air(cfm /s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF Outside Air -4 V- 0 cfm 69 OF 69 OF 113 OF 113 OF D i M Supply Fan Heating Coil 111 OF 1,600 cfm R OM 70 OF i I J COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F Outside Air 0 cfm 80/64°F 80/64°F 57/55°F /-� 57/55°F t���� - Cooling Coil Supply Fan 1,600 cfm 45.7% 58 / 56 OF ROOM 78/64°F EnergyPro 5.1 by EnergySoft User Number. 6712 Run Code: 2010-10-22714:54:15 ID: Page 11 of 15 • • ROOM LOAD SUMMARY Project Name John Owen Alteration System Name HVAC -1 ROOM LOAD SUMMARY Date 10/22/2010 Floor Area 2,682 ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name Mult. CFM Sensible Latent CFM Sensible Latent CFM Sensible Alteration Alteration 1 1,452 30,588 2,695 1,452 30,588 2,695 7871 34,490 PAGE TOTAL TOTAL ' 1,452 30,588 2,695 787 34,490 1,4521 30,5881 Z6951 787 34,490 Total includes ventilation load for zonal systems. EnerqyPro 5.1 by EnemySoft User Number: 6712 Run Code: 2010-10-22714:54:15 ID: Pae 12 of 15 • • ROOM HEATING PEAK LOADS Project Name John Owen Alteration Date 10/22/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Alteration Floor Area 2,682. 0 ft' Indoor Dry Bulb Temperature 70 OF Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area U -Value X 0.0310 X 0.1100 X 0.4000 X 0.7100 X 0.7300 X X X X X X X X X X X X X X X X X X X X X X X X X X to another room 9.50 X 0.372 Ceiling Height ACH X x X X X X X X X X X X X X X X X X X X X X X X X X X X X X X AT *F = = = = = = 44 Btu/hr R-30 Roof Attic 2,682.0 44 3,658 Default Wall 1978 to 1991 1,690.6 44 8,183 Double Non Metal Tinted 260.0 44 4,576 Double Metal Clear 114.4 44 3,574 Slab -On -Grade perim = 221.0 44 7,099 Items shown with an asterisk (`) denote conduction Infiltration:[ 1.00 x 1.064 Schedule Air Sensible Fraction through an interior surface X 2,682 X Area Page Total /60] X AT 27.089 = 7,401 TOTAL HOURLY HEAT LOSS FOR ROOM 34,490 Energ Pro 5. 1 by Energ Soft User Number: 6712 Run Code: 2010-10-22714:54:15 ID: Page 13 of 15 r1 .7 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name John Owen Alteration ROOM INFORMATION DESIGN CONDITIONS 10/22/2010 Room Name Alteration Outdoor Dry Bulb Temperature 112 OF Floor Area 2, 682.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF Outdoor Daily Range: 34 OF Opaque Surfaces R-30 Roof Attic Default Wall 1978 to 1991 Default Wall 1978 to 1991 Default Wall 1978 to 1991 Default Wall 1978 to 1991 Orientation (N) (E) (S) Area X X X X X X X X X U -Factor X X X X X X X X X CLTD' = = = = = = = = = Z682.0 0.0310 56.0 264.0 0.1100 23.0 503.0 0.1100 33.0 421.6 0.1100 26.0 502.01 0.1100 33.0 21.0 20.0 41.8 0.0 41.3 4.0 84.6 0.0 41.3 4.0 84.6 0.0 41.3 20.0 Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded I Fenestration Window Window Window Window Window Window Window Window Window Orientation (N) (N) (N) (E) (E) (E) (E) (S) (S) Btu/hr 4,656 668 1,826 1,206 1,822 1 10,1781 Area X X X X X X X X X GLF + + + + + + + + + Area X X X X X X X X X GLF = = = = = = = = = 0.0 21.0 80.0 21.0 0.0 21.0 80.0 21.0 0.0 21.0 80.0 21.0 0.0 21.0 20.0 41.8 0.0 41.3 4.0 84.6 0.0 41.3 4.0 84.6 0.0 41.3 20.0 84.6 0.0 41.3 23.2 41.5 0.0 41.3 20.0 41.5 Page Total Btu/hr 1,679 1,679 1,679 835 339 339 1,693 962 829 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. Equipment 1.0 Dwelling Unit X 1,600 Btu Infiltration: 1.064 X 0.87 X 166.07 X 34 = C Air Sensible CFM ELA AT I TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,5881 Latent Gain Btu/hr Occupants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 166.07 X 0.00276 = 1,895 Air Sensible CFM ELA AW • , TOTAL HOURLY LATENT HEAT n RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date John Owen Alteration 1 10/22/2010 ROOM INFORMATION DESIGN CONDITIONS Room Name Alteration Outdoor Dry Bulb Temperature 112 OF Floor Area 2, 682.0 ftz Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 78 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U -Factor CLTD' Btu/hr X X = X X = X X = X X = X X = X X = X X = X X = X X = Page Total 0 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Window (S) 0.0 X 41.3 + 23.2 X 41.5 = 962 Window (w) 0.0 X 41.3 + 20.0 X 84.6 = 1,693 X + X = X + X — X + X - X + X - X + X - X + X - X +1 XI - Page Total 2,654 Internal Gain Btu/hr Occu ants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.87 X 166.07 X 34 a 5,203 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 30,588 Latent Gain Btu/hr Occu ants 4.0 Occupants X 200 Btuh/occ. = 800 Infiltration: 4,771 X 0.87 X 166.07 X 0.00276 = 1,895 Air Sensible CFM ELA AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 2,695 EnervyPro 5. 1 by Ene SoR User Number: 6712 Run Code: 2010.10-22714:54.15 /D: Pae 15 of 15