Loading...
11-0555 (RER)P.O. BOX 1504 T4hi 4 VOICE (760) 777-7012 78-495 CALLE TAMPICO FAX (760) 777-7011 LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 7/08/11 Application Number: 11-00000555 Owner: Property Address: 49826-COACHELLA DR JOHN P. OWEN APN: 646-250-013-13 49-826 COACHELLA DRIVE Application description: REMODEL - RESIDENTIAL LA QUINTA, CA 92253 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 12000 I F�7 Contractor: Applicant: Architect or Engineer: Owner yui_ 2011 L 0 -A QUNTA ------------------------------------------------------------------------------------------------- LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: . License No.: Date: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State. License Law (Chapter 9 (commencing with Section 7000l of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason /1"Date: Owner: CONSTRUCTION U I hereby affirm under penalty of perjury that there is a construction work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIIT for the performance of the WORKER*S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: * I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the*Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier F Policy Number I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if�l �should �becomebj t t LtheO.rkers' compensation provisions of Section �700 of thq Labor Code- I shall forthwith com with those provisions. Date: 711� �//pplicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSAT4`COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS J$100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. I . Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and he b thorize representatives of th*;; the above-mentioned prqEg� Wf, t ;a Ze u ure (Applicant or Agent): u �74�;Signav 7TW;9z V Application Number . . . . . 11-00000555 Structure Information Construction Type . . . . . TYPE V, UNPROTECTED Occupancy Type . . . . . . HOTEL/APT/CONG HSING >10 Other struct info . . . . . CODE EDITION 2010 ----------------------------------- # BEDROOMS : ----------------------------------------- ..00 Permit . . . . . . BUILDING PERMIT Additional desc Permit Fee 135.00 Plan Check Fee 87.75 ,,Issue Date . . . . valuation . . . . 12000 Expiration Date 1/04/12 Qty Unit Charge Per Extension BASE FEE 45.00 10.00 9.0000 -------------------------- THOU BLDG 2,001-25,000 -------------------------------------------------- 90.00 Permit . . . . . . ELECT - AD D/ALT/REM Additional desc . . - Permit Fee . . . . 61.95 Plan Check Fee 15.49 Issue Date Valuation . . . . 0 Expiration Date 1/04/12 Qty Unit -Charge Per Extension BASE FEE 15.00 20.00 .7500 PER ELEC DEVICE/FIXTURE 1ST 20 15.00 71.00 .4500 ---------------------------------------------------------------------------- EA ELEC DEVICt/FIXTURE >20 31.95 Permit . ... . . . PLUMBING Additional desc Permit Fee . . . . 72.00 Plan Check Fee 18.00 Issue Date . . . . valuation . . . . 0 Expiration Date 1/04/12' Qty Unit Charge Per Extension BASE FEE 15.00 8.00 6.0000 EA PLB FIXTURE 48.00 1.00 3.0000 FRA PLB WATER INST/ALT/REP 3.00 1.00 3.0000 EA PLB FIXTURE DRAIN/VENT REP/ALT 3.00 1.00 3.0000 EA PLB GAS PIPE 1-4 OUTLETS 3.00 -------------------------------------------------------------- Special Notes and Comments REMODEL TO KITCHEN,.2 BATHS, ENTRY AND ENTRY PATIO. REPLACEMENT OF WINDOWS AND SKYLIGHTS. 2010 CODES LQPERMIT Application Number . . . . . 11-00000555 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 ENERGY REVIEW FEE 8.78 STRONG MOTION (SMI) - RES 1.20 Fee summary Charged Paid Credited Due ----------------- Permit Fee Total ---------- 268.95 ---------- ---------- ---------- .00 .00 268.95 Plan Check Total 121.24 .00 .00 121.24 Other Fee Total 10.98 .00 .00 10.98 Grand Total 401.17 .00 .00 401.17 LQPERMIT P.O. Box 1504 LAQUINTA" CALIFORNIA 92247-1504. 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 I BUILDING & SAFETY DEPARTMENT PROPERTY OWNER'S PACKAGE (760) 777 -7012 FAX (760) 777-7011 Disclosures & Forms for Owner -Builders Applying for Construction Permits 4WARMT! NOTICE TO FROfERTY OWNIER Dear Property Owner. Aii. application for a building permit has been submitted in your name listing yourself as the builder of the Property impr,ovements specified at pja We am providing you with a� Owner -Budder Acknowtedgmenvand Ififormation Verification Form to mAe You aware Of Your responsibilities and possible risk YOU MY Wcur by having this pevant issued in your name as the. Owner -Builder. We will not . issue a building permit until you -have read, initialed your understanding of eacliVrovisi011, signed, and returned this form to us at our official address indicated. Am agent of the owner cannot execute this`ti�e unless you, the property owner, obtain the prior approval of the permitting authority. OVRUW,S AC1Qq0WLEVGMNT AND'VERMCAMN OF -HN2HMAn2_N DfiWMONS; Read and initial each statement below to signify you understand or ven)� this Kormation. ensed perwns is to"have,the,property owner Obtain an I'Owncr-lWdee, 1. 1 understand a frequent practice of unlic building perinit that erroneously implies that the property owner is providing his or her own labor and material PersonAy- 1, as an Owner -Builder, may be held liable and subjed to serious financial- risk for any injuries sustained by an unlicensed person and his or her employees while working on my property.'My homeowner's insurance may not provide coverage for those injunies. I am willfully acting as an Owner -Budder and am aware of the limits of my insurance -coverage for injuries to workers on MY property- r-, -7 rs unless they are responsible for the JW2. I understand building permits are not required to'be signed by property Owne C86truction and are not hiring a licensed Contractor to assume this responsibility - 3 , I understand as an "Ownet-Buildee' I am the resp'onsible party of record on the permit- I understand that 1 may Protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his.or her name inste&d Of my own. - --I - jj��4. 1 understand Contractors are required byllaw to be licensed and bonded in Calif'Dn-tia and to list their license numbers ow permits and contracts. fW5. I understand if I employ or otherwise engage any'persons, other than California licensed ContmetOts, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered I an "employer" under state and federal law. V6I understand if I am considered an "employee' under state and federal . law, I must register with 'he State 111 _ ili insuran an ontribute to unemployment government, withhold payroll taxes, provide workers' compensation disab V ce, d c compensation for.each "employee." I also- understand my'failure to.abide by ttiese laws may subject me to serious ri"al risk. I understand under California Contractors' State Lic . ense Law, an owner -Builder who builds single-family residential nless 1 0 is rf rmed by licensed structures cannot legally build them with the intent to offer them for sale, u a I w rk pe o subcontractors and the number of structures does -not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. AI understand as an Owner -Builder if I sell the property for which this pernuit is issued, I may be held liable for any 2cial or personaf ti e ects in th 4uries sustained by.any subsequent owner(s) that result from any latent construe on d f e woricmanship or materials. t9obligations 'as an "employee' from the Internal Revenue I understand I may obtain more information regarding my , the United States Small Business Administration, the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CS'LB) at I - 800-321-CSLB (2752) or www.csib.ca.gov for more information about licensed contractors. 10. 1 am aware of and consent to an Own er-Builder building permit applied for in my name, and understand that I am the legally and financially responsible for proposed construction activity at the following address: &I L I agm that, as the party legally and fumaciall y responsible for this proposed construction activity, I will abide by all apVficable laws and requirements that g*overn Owner -Builders as well as employers. q2. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the infbmlati(m I hav provided on this form. Licensed contractors are regulated by taws designed to protect the public. If you contract with someone who does not have a Imense, the, Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint Your only remedy against unlicensed Contractors may be inVivil court It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firra is injured while w0fking on Your Property; you may be held liable for damages. If you obtain a permit as* Owner -Builder and wish to hire Contmaors, You Will be responsible for verifying wh�— or not those Contractors are property licensed and the sutus of ftir workers' compensation insurance coverage. Before a building perndt can be issued, this form must be completed and signed by the prop" owner and returned to the agency responsible for issubg:d&e.permit NoW A cop y of the propen'y owner's dkiver's I&Wnsei f0m n01M0*W0F4 or other venTw:ation accVtable to the agency is m4uired to be presented when the pennit is issued to vel* the Pr0pen*Y owner's signature. Signature of property owner 04A.— Date- 4�, Note: Thefollowing Authorization Form is �equired to be completed by the property owner only when designating an agent ofthe property owner to applyfor a construction per7nitfor the Owner -Builder. AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWN—E—W—S—B—E—E[A—LF Excluding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner -Builder Permit for my project. Scope of Construction Project (or Description of Work): a, Rem Project Location or Address: Name of ?kudiorized Agent: M6 i��, a n at� A /10t)r o TeIN Address of Authorized Agent: � , I declare under penalty of perjury that I am the property owner for the address listed above and I pemnally filled out the above information and certify its accuracy. Note: A copy ofthe owner's driver's ficense, form notarization, or other verification acceptable to the agency is required to be presented when the permit is issued to verify the property owner's signature.. Property Owner's Signature: to Date: 4� THE ISLANDS HOMEOWNERS ASSOCIATION No. 4 June 20, 2011 John Owen 310 W. 49th St., #403 Kansas City, MO 64112 Re: 49826 CoacheUa Architectuml Request Dear Mr. Owen: The Board of Directors has reviewed you request to lower the courtyard wall in the front and the patio extension in the rear. After careful consideration, the Board of Directors has approved the street side request to lower the courtyard wall with the paint to match the existing color and all plantings are to remain in place. As to the golf course extension, the Board of Directors has denied the six (6) foot extension as the current patio edge is the lot line. They did, however, approve the three (3) foot extension of the existing patio to the edge of the master bedroom slider. Should you have any questions, please feel free to contact us. Sincerely, By Direction of the Board of Directors Rosie Galla, CCAM Community Association Manager Cc: Marianne Nouskajian Bin # Qty of La Quinta Building 8T Safety D!vLsloh P.O. Box 1504, 78-495 Calle Tampico LaQuinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address: 4 C)- Owner's Narne:,%s� A. P. Number: b4-,61&2SCD C_) I Address: -4 E3 Legal Description:Larr� 7[7r Z+ -0 7 City, ST, Zip:6&,- C�:�U I el-kT%- Contractor: 6W&1Er--11PUf (-PCP— -M.N. Telephone: Project Description: Address: City, ST, Zip: M City Lic. CZ-(Telephone: State Lic. # A,ShmFmw., Designer. r--CXr7; TC Address.,- 7, Z_ 4,--o C) City, ST, Zip:'P��-> 4� -Z Telephone:5.41-3 2-a5-7 Construction Type: Occupan*cy: State Lic. #: Project type (circle one): New Add'n Alter Repair Demo Name.of Contact Person: Sq. Ft.: Stories: # Units: Telephone # of Contact Person: -�*f 6 Estimated Value of Project: APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Rccld !N�qp;Tx 7IL—dT- PERMIT FEES Plan Sets Plan Check submitted Item Amount' Structural Ca Ics. Reviewed, ready Plan Ch eck Deposit f0(-rrectiU;x)V 9 7 U 1 7 Truss CaIcs. Ad - Called Contact Person b , Plan Check Balance. Title 24 Caics. 10 Plans picked up 1SWICoustruction Flood plain plan Plans resubmitted V Mechanical Grading plan 2" Review, ready fokcorrcction &sue Electri cal Subcontactor List Called Contact Person jt��-T #"S _M10 Plum ing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted 7/-7 Grading IN HOUSE:- Re -view, ready for correction ue 17 Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees f Total Permit Fees 7 610. Jmt� Vat, ?"� 41P E BUILDING ENERGY ANALYSIS REPORT PROJECT: John Owen Alteration 49-826 Coachella La Quinta, CA 92253 Project Designer: Robert A. Pitchford, Design and Drafting 77-622 Country Club, Suite 0 - Palm Desert, CA 92211 (760) 346-2856 Report Prepared by':, Jon Scott Scott Design and Title 24, 1 .77-085 Michigan Drive Palm Desert, Ca 92211 (760) 200-4780 Job Number: Date: 5/25/2011 I (f 'CITY OF LA QUINTA 13UILDING & SAFETY DEPT. APPROVED F R _77ONSTRUCTION vad - DATEI� 191 IJI t5T- RJECEaVMD MAY 2 7 2011 3V �� The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC — www.energysoft.com. EnenZVFT 5. 1 by EnergySoft User Number- 6712 RunCode: 2011-05-25T20.45:11 ID: 0 w I TABLE OF CONTENTS I Cover Page 1 Table of Contents 2 Form CF -1.R Certificate of Compliance 3 Form M F-1 R Mandatory. Measures Summary 9 HVAC System Heating and Cooling Loads Summary 12 I EnergyPro 5.1 by Energysoft Job Number ID: User Number: 6712 1 PERFORMANCE CERTIFICATE: Residential (part 1 of 5) CF -1 R Project Name John Owen Alteration Building Type 0 Single Family 0 Addition Alone 11 Multi Family 0 Existing+ Addition/Alteration Date 512512011 Project Address 49-826 Coachella La Quinta California Energy Climate Zone CA Climate Zone 1 5 Total Cond. Floor Area 2,682 Addition 0 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST • Yes IZI No HERS Measures If Yes, A CF -4R must be provided per Part 2 of 5 of this form. • Yes IZI No Special Features If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity (ft) Features (see Part 2 of 5) Status Roof Wood Framed Attic R-30 Z680 Existing Wa // Wood Framed R-11 1,729 Existing Slab Unheated Slab -on -Grade None 2,682 Perim = 221' Existing FENESTRATION U- Orientation Area(ft) Factor Exterior SHGC Overhang Sidefins Shades Status Skylight 0.8 0.300 0.30 none none None New Skylight 0.8 0.300 0.30 none none None New Skylight 0.8 0.300 0.30 none none None New Rear (N) 240.0 0.400 0.35 none none Bug Screen Existing Right (E) 20.0 0.400 0.35 none none Bug Screen Existing Right (E) 28.0 0.710 0.73 none none Bug Screen Existing Front (S) 28.3 0.400 0.35 none none Bug Screen New Left (VL9 20.0 0.710 0.73 none none Bug Screen Existing HVAC SYSTEMS Oty. Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 78% AFUE Split Air Conditioner 11.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating Duct Cooling Duct Location R -Value Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING Qty. Type Gallons Min. Eff Distribution Status EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T20.45:11 ID: Page 3 of 12 0 PERFORMANCE CERTIFICATE: Residential (part 2 of 5) CF -1 R Project Name John Owen Alteration Building Type 0 Single Family 0 Addition Alone 0 Multi Family 0 Existing+ Addition/Alteration Date 1512512011 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. EnemyPro 5. 1 by EnergySoft User Number., 6712 RunCode: 2011-05-25T20.-45:11 ID: Page 4 of 12 0 0 PERFORMANCE CERTIFICATE: Residential . (part 3 of 5) CF -1 R Project Name Building Type 10 Single Family 1:1 Addition Alone Date John Owen Alteration 1 0 Multi Family 0 Existing+ Add iti on/Alte ration 15125�2011 ANNUAL ENERGY USE SUMMARY Standard Proposed margin TDV (kBtu/ft?-yr) Space Heating 4.71 5.78 -1.07 Space Cooling 119.34 108.54 10.79 Fans 22.59 20.68 1.91 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 146.64 135.00, 11.64 Percent Better Than Standard: 7.9% BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (S) 180 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 1.00 (S) 488 28 Fuel Available at Site: Natural Gas (1/10 522 20 Raised Floor Area: 0 (N) 504 240 Slab on Grade Area: 2,682 (E) 551 48 Average Ceiling Height: 9.5 Roof Z682 2 Fenestration Average U -Factor: 0.44 TOTAL: 339 Average SHGC: 0.40 Fenestration/CFA Ratio: 12.6% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed. to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and, comple Documentation Author Company Scott Design and Title 24, Inc, 512512011 Address 77-085 Michigan Drive Name Jon Scott City/State/Zip Palm Desert, Ca 92211 Phone (760) 200-4780 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and buildin eali require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company Robert A. Pitchford, Design and Drafting Address 77-622 Country Club, Suite 0 Name Robert A. Pitch City/State/Zip Palm Desert, CA 92211 Phone (760) 346-2856 Signed Licene4r Date EnergyPro 5.1 by Ener-qySoft User Number- 671 RunCode: 2011-05-25T20.45:11 ID: Page Ah MW 0 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name John Owen Alteration Building Type 0 Single Family 0 Addition Alone 0 Multi Family [Z Existing+ Addition/Alte ration Date 1512512011 OPAQUE SURFACE DETAILS Surface Type Area U- Insulation Joint Appendix Fadtor Cavity Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Roof Z680 0.031 R-30 270 0 Existing 4.2. I -A20 Alteration Wall 264 0.110 R-11 0 90 Existing 4.3. I -A2 Alteration Wall 503 0.110 R-11 90 90 Existing 4.3. I -A2 Alteration Wall 460. 0.110 R-11 180 90 Existing 4.3. 1-A2 Alteration Wall 502 0.110 R-11 270 90 Existing 4.3. 1-A2 Alteration Slab 2,682 0.730 None 0. 180. Existing 4.4.7-A 1 Alteration ---------------- FENESTRATION SURFACE DETAILS ID Type Area U -Factor' SHGC�� Azm Status Glazing Type Location/Comments I Skylight 8.0 0,840 Default 0.55 Default 270 Removed Existing Skylight Alteration 2 Skylight 8.0 0.840 Default 0.55 Default 270 Removed Existing Skylight Alteration 3 Skylight 4.0 0.840 Default 0.55 Default 270 Removed Existing Skylight Alteration 4 Skylight 0.8 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Alteration Skylight 0.8 0.300 NFRC 0.30 NFRC 270, New Solatube Skylight Alteration -5 6 Skylight 0.8 0.300 NFRC 0.30 NFRC 270 New Solatube Skylight Alteration 7 Wndow 80.0 0.400 NFRC 0.35 NFRC 0 Existing Double Non Metal Tinted Alteration 8 Window 80.0 0.400 NFRC 0.35 NFRC 0 Existing Double Non Metal Tinted Alteration 9 Wndow 80.0 0.400 NFRC 0.35 NFRC 0 Existing Double Non Metal Tinted Alteration 10 Window 20.0 0.400 NFRC 0.35 NFRC 90 Existing Double Non Metal Tinted Alteration 11 Wndow 4.0 0.710 Default 0.73 Default 90 Existing Double Metal Clear Alteration 12 Window 4.0 0.710 Default 0. 73. Default 90 Existing Double Metal Clear Alteration 13 Window 20.0 0.710 Default 0. 73 Default 90 Existing Double Metal Clear Alteration 14 Window 23.2 0.710 Default 0.73 Default 180 Removed Double Metal Clear Alteration 15 Window 20.0 0.710 Default 0.73 Default 180 Removed Double Metal Clear Alteration 16 Window 3.2 0,710 Default 0.73 Default 180 i?emoved Double Metal Clear Alteration (1) Ll -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value (2) SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS ID Exterior Shade Type SHGC Window Hat Wd Ove hang Left Fin Len H t I -Ext RExt Dist Len Right Fin Hqt Dist Len Hgt 1 None 1.00 2 None 1.00 3 None 1.00 4 None 1.00 5 None 1.00 6 None 1.00 7 Bug Screen 0.76 8 Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen 0.76 13 Bug Screen .0.76 14 Bug Screen 0.76 15 Bug Screen 0.76 16 JBug Screen 0.76 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T20.45:11 ID: Page 6 of 12 0 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name John Owen Alteration Building Type 0 Single Family 13 Addition Alone 0 Multi Family 10 Existing+ Add it io n/Alte ration Date 1512512011 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Exterior Frame Interior Frame Azm Tilt Status 4 Location/Comments _q4y!t( . . 'D-ETAIL§ FENEST RATIO N SURFACE ID Type Area U -Factor' SHGC Azm Status Glazing Type Location/Comments 17 Window 4.8 0.400 NFRC 0.35 NFRC 180 New Double Non Metal Tinted Alteration 18 Window 23.5 0.400 NFRC 0.35 NFRC 180 New Double Non Metal Tinted Alteration 19 Window 20.0 0.710 Default 0.73 Default 270 Existing Double Metal Clear Alteration (1) U -Factor Type: 11 6-A = Default Table from Standards, NFR� = Labeled Value (2) SHGC Type: 11 6-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window Ove hang Left Fin Right Fin ID Exterior Shade Type SHGC Hgt Wd Len Hgt I -Ext FlExt Dist Len Hgt Dist Len Hgt 17 Bug Screen 0.76 18 Bug Screen 0.76 19 Bug Screen 0.76 EnergyPro 5. 1 by EnergySoft User Number- 6712 RunCode: 2011-05-25T20.45:11 ID: Page 7 of 12 0 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name John Owen Alteration Building Type 0 Single Family 0 Addition Alone 0 Multi Family 121 Existing+ Addition/Alteration Date � 512512011 BUILDING ZONE INFORMATION System Name Zone Name Floor ea (ft New Existing Altered Removed Volume Year Built HVAC -1 Alteration Z682 25,479 1980 Totals 01 Z6821 01 0� HVAC SYSTEMS System Name Qty. Heatin Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVAC -1 1 Central Furnace 78%AFUE Split Air Conditioner 11. 0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Cooling Duct Location R -Value Ducts Tested? Status HVAC -1 Ducted Ducted Attic, Ceiling Ins, vented 4.2 Existing WATER HEATING SYSTEMS System Name Qty- Type Distribution Rated Input (13tuh) Tank Cap. (gal) Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R - Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length 0 System Name Pipe Len th Pipe Diameter Insul. Thick. oty. H P Plenum Outside � Buried 1 01 1 11 0 0 0 EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T20.*45:11 ID: Page 8of12 IF— LL__ MANDATORY MEASURES SUMMARY: Residential (Page 1 of 3) MF -1 R Project Name �ohn Owen Alteration Date 1 512512011 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Building Envelope Measures: §1 16(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §1 16(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration that meets the requirements of §10-111 (a). §117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. §1 18(a): Insulation specified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §1 18(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §1 18(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *§1 50(a): Minimum R-1 9 insulation in wood -frame ceiling or equivalent U -factor. §1 50(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50(c): Minimum R-1 3 insulation in wood -frame wall or equivalent U -factor. *§1 50(d): Minimum R-13 insulation in raised wood -frame floor or equivalent U -factor. §1 50(f): Air retarding wrap is tested, labeled, and installed according to ASTM El 677-95(2000) when specified on the CF -11 R Form. §1 50(g): Mandatory Vapor barrier installed in Climate Zones 14 or 16. §1 50(l): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0 perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces, Decorative Gas Appliances and Gas Log Measures: §15 (e)lA: Masonry or factory -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §1 50(e)l B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and tight -fitting damper and or a combustion -air control device. §1 50(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §1 13(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §1 13(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and spa heaters. §1 50(h): Heating and/or cooling loads are calculated in accordance with ASHRAE, SMACNA or ACCA. §1 50(i): Heating systems are equipped with thermostats that meet the setback requirements of Section 11 2(c). §1500)1 A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-1 2 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-1 2 external insulation or R-1 6 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulate per Standards Table 150-B. §1506)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >1 5 psi, meets the requirements of Standards Table 123-A. §1 50(j)3A: Insulation is protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. §1 500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vapor retardant or is enclosed entirely in conditioned space. §1 50(j)4: Solar water -heating systems and/or collectors are certified by the Solar Rating and Certification Corporation. EnergyPro 5.1 by EnergySoft User Number. 6712 RunCode: 2011-05-25T20.-45:11 ID: Pa 4 As q5 �7� MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3) MF -1 R Project Name Date �ohn Owen Alteration 1512512011 §1 50(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181 B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §1 50(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §1 50(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §1 50(m)7: Exhaust fan systems have back draft or automatic dampers. §1 50(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. §1 50(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. §1 50(m)l 0: Flexible ducts cannot have porous inner cores. §1 50(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. Pool and Spa Heating Systems and Equipment Measures: §1 14(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Eff iciency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating or a pilot light. §1 14(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. §1 14(b)2: Outdoor pools or spas that have a heat pump or gas heater shall have a cover. §1 14(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or programmed to run only during off-peak electric demand periods. §1 50(p): Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §1 50(p). Residential Lighting Measures: §1 50(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the eff icacies contained in Table 150-C and is not a low eff icacy luminaire as specified by §1 50(k)2. §1 50(k)3: The wattage of permanently installed luminaires shall be determined as specified by §1 30(d). §1 50(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §1 50(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §1 30(d), and shall not contain a medium screw -base socket. §1 50(k)6: Lighting integral to exhaust fans, in rooms other than kitchens, shall meet the applicab e requirements of §1 50(k). §1 50(k)7: All switching devices and controls shall meet the requirements of §1 50(k)7. §1 50(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §1 50(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of power per linear foot of illuminated cabinet. EnergyPro 5.1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T20.-45:11 ID: Page 10 4 a MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3) F-1 R Project Name Date Lohn Owen Alteration V2512011 §150(k)10: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §1 50(k)l 1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §1 50(k)l 1. §1 50(k)l 2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTIVI E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §1 50(k)l 3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §1 50(k)l 3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. I §1 50(k)l 4: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §1 50(k)l 5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §1 50(k)l 6: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensor(s) certified to comply with the applicable requirements of §119. EnergyPro 5.1 by EnergySoft User Number 6712 RunCode: 2011-05-25T20.-45:11 ID: Page 11of12 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name en Alteration Date 5/25/2011 System Name HVAC -1 Floor Area 2,682 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COOLING PEAK COIL HTG. PEAK Heating System Sensible Latent CFM Sensible Output per System 75,000 28,676 2,695 754 33,127 Total Output (Btuh) 75,000 0 Output (Btuh/sqft) 28.0 2,432 2,354 Cooling System 0 0 Output per System 48,000 0 01 0 0 Total Output (Btuh) 48,000 0 2,6795 0 Total Output (Tons) 4.0 2,432 2,354 Total Output (Btuh/sqft) 17.9 Total Output (sqft/Ton) 670.5 33,539 37,834 Air System CFM per System 1,600 HVAC EQUIPMENT SELECTION Airflow (cfm) 1,600 Existing System 38,850 3,195 75,000 Airflow (cfm/sqft) 0.60 Airflow (cfm/Ton) 400.0 Outside Air (%) 0.0% Total Adjusted System Output 1 38,8501 3,195 (Adjusted for Peak Design conditions) I TIME OF SYSTEM PEAK Aug 3 PM1 75,000 I Jan 1 AM Outside Air (cfm/sqft) 0.00 es above given at ARI conditions SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Heating Peak) 26 OF 69 OF 11 3,OF 113 OF Outside Air Sup I ply Fan 0 cfm Heating Coil 111 OF 1,600 cfm (-77- 69 OF 70 OF .4 W COOLING SYSTEM PSYCHROMETICS (Airstream Temperatures at Time of Cooling Peak) 112 / 78 OF 79 / 64 OF 57 / 55 OF 57 55 OF OutsideAir -4. 0 cfm Cooling Coil Supply Fan 58 56 OF 1,600 cfm — 45.6% 0M 79 / 64 OF 78 / 64 OF EnergyPro 5. 1 by EnergySoft User Number: 6712 RunCode: 2011-05-25T20.45:11 ID: Page 12