Loading...
13-0335 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 r BUILDING & SAFETY DEPARTMENT BUILDING PERMIT Application Number: 13-00000335 Property Address: 79575 RANCHO SANTA MARGARITA APN: 649-610-003-3 -28964 - Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 36071 Applicant: Architect or Engineer: �ota'lE'Wtt/1► � LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B��11C10 C46 per. /�,�w _LLice��nseNNoLo__:..910836 Date: H� rJ ' Contractor: P W 0V#4 �1 OWNER -BUILDER DECLARATION' I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to , construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the.Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 15500)•: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The . Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within - ane year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). _ - (_ 1 I am exempt under Sec. , B.&P.C. for this reason Date: Owner: . CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: ARCHULETA, LUPE & ELAINE 79575 RANCHO SANTA MARGARITA LA QUINTA,.CA 92253 Contractor: RENOVA ENERGY CORP 75181 MEDITERRANEAN A PALM DESERT, CA 92211 (760)568=3413 Lic. No.: 910836 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 4/29/13 ----------------------------------------------- WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is Jissued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUND Policy Number 9024501-12 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 37``00 of the Labor Code, I shall forthwith comply with those provisions. 1Xate: u'u %5 Applicant: WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation.. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-mentioned property for inspecaion purposes. f- s � mate: �Iv' Signature (Applicant or Agent): Application Number . . . . 13-00000335 Permit . . . SOLAR PERMIT Additional d_esc . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . . 36071 Expiration Date 10/26/13 Qty Unit Charge .Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 ----------------------------------------------------------------------------- EA SOLAR EQUIP MISCELLANEOUS 3.00 Permit . . . ELEC-MISCELLANEOUS Additional desc . Permit Fee . . . . 30.00 Plan Check Fee 7.50 Issue Date . . . Valuation . . . . 0 Expiration -Date 10/26/13 Qty Unit Charge Per Extension . BASE FEE 15.00 2.00 7.5000 EA ELEC PWR APP >1 TO <=10 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 14.7kW SOLAR ARRAY - (45) 327W SUNPOWER PANELS W/,(1) 7,000W & (1) 6,000W SUNPOWER INVERTER (815SF] 2010 CALIFORNIA ELECTRICAL CODE. April 29, 2013 8:49:05 AM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . .. . . . BLDG STDS ADMIN (SB1473) 2.00 Fee summary Charged Paid Credited Due Permit Fee Total 52.50 .00 .00 52.50 Plan Check Total 13.13 .00 .00 13.13 Other Fee Total 2.00 .06 .00 2.00 Grand Total 67.63 .00 .00 67.63 LQPERA1IT Bin.# Cllr Of 4 Qu1n: td Building a Safety Ai&6n P.O. Box 1504,78-495 Calle Tampico La.Quinta, CA 92253 -:(760) 777-7012 Building Permit -Application and Tracking Sheet Permit # .13 ' �� Project Address: 79575Rancho Santa Margarita Owner's Name: Tommy Archuleta A. P. Number. Address:79575 Rancho Santa Margarita Legal Description: Contractor: Rehova Energy Corp. City, ST, Zip: La Quirita, CA 92253 Telephone. ,... IM- �s Address: 75181 Mediterranean Ave Project Description: Residential Roof Mounted Solar P 14.7kW DC City, sT, Zip: Palm Desert, CA 92211 y Z" + 6*JD W .Wpe&OZ r`u n Telephone: 760-568-341345) State Lie. # :910836 City Lic #,,104947, Arch., Engr., Designer. Address: City, ST, Zip: Telephone: Construction Type:. occupancy: Residential . State Lic. #:� Project type (circle one): New Add'n Alter Repair Demo Name of Contact Person: Lea Waki - 760-568-3413. Sq. Ft.: 3640 # Stori es: 1 # Units: Telephone # of Contact Person: lea@renovasolar.com Estimated Value of Project: $36 071:00 APPLICANT: DO NOT WRITE BELOW THIS UNE # Submittal Req'd Recd TRACKING PERMIT FEES- EESPlan PlanSets Plan Check submitted �8 Item Amount Structural Cales. Reviewed, ready for corrections 126 /1 lan Check Deposit • . Truss C21cs. Called Contact Person Plan Check Balance. Tide 24 Calci. Plans piciced up I?j Construction Flood plain plan Plans resubmitted Mechanical Grading plan tad Review, ready for rnrrectio Electrical Subcontactor List ,et Called Contact Person y Plumbing Grant Deed Plans picked up S.M.I. HOA Approval Plans resubmitted Grading IN HOUSE:- ''d Review; ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. VVke. Appr Date of permit issue School Fees Total Permit Fees 61'; ^. 3�� ?,at3 - .Saw►ti- Ric.•. ' �4�vS Ste. oft. — E, . %&A-1 w JbPP r c i . �l7 x Assoda Well A � Desert {o3 Management March 14, 2013, Mr. & Mrs. Archuleta 79575 Rancho San Margarita La Quinta, CA 92211 RE: Talante Homeowners Association ' Dear Mr. & Mrs. Archuleta, The Talante Board of Directors met on 3/14/13 to review your 3/12/13 submittal requesting solar panels on the roof. After due consideration the Board of Directors has approved your request contingent on the following items: 1. Owner must obtain all permits through City of La Quinta. 2. Owner must sign and return Indemnity Agreement prior to starting installation. If you have any questions please call me at (760) 346-1161. Thank you for your patience duringthereview process. Si gely, Carol Calhoun, CCAM© Community Association Manager For the Board of Directors Talante Homeowners Association Enclosure: Indemnity Agreement 42-635 MelaniO'Pl6ce, Suite103 Palm Desert, CA 92211 Tcc!vphoim 760-346-1161 fax 760.346-9918 W04 Assoda' The leader in•community association management www.associaonline.com SINGLE FAMILY DWELLING LOAD CALCULATION Customer Name: A &,.kAU*,-\ Z -'V k 1. :OTH'IERIOADS=220A.0(b) General lighting loads -- 40 sq ft 1 x-3 VA=' 10,9110 VA Sm'aWappliph eandlauh.dry loads 2261o3q(b)(1 150.0 V'A-x :Qrcu*ts= A,15po --VA Special loads —22Q-.30(lI-)*( .Dish'washer-=. VA VA Compactor= VA Water heater= VA L- VA —VA VA p6tdia.1)". Zjc1 L.k i'b NA Applying demand factors,- Taible-220'30,(4) First 10,09.0'VA;XI00% = .10.000 VA 5. ,X �,P _ qaining,.. VR,,V Aemkx,.46% 2. HEATING OR A/C LOAD=Table 226--'30(1)(2)(3}: I , . - , ., , , .. Heating units (Ior less) =: U()' )' Vkxtsvo Heating unitsmore) #.' Rdr' (2�,A/C unit VAX 100%' He 'A at.Pump- v --x 100%-_= 3. 8,000 VANONDERAIEDTUTURE SERVICE :: .J.,= VA V !(Total #2 1006t Load) .0 , o -7VA VA: 600 VA: VA 1W�000 VA 8;jDOO VA (Total l+ Tot-*I.,2+8000)**rOT--AL= 2-M j ta (b VA .S.+EAVICE: !*Y1;1.&VA 240 Servide adiperes',reWired 'S.er..V'.fc,e ampetes,orovided L-).Vc- WORK TO BE PERFORMED ACCORDING TO THE " SOLAR SYSTEM SIZE: 14.715 kW DCFU ST, FOLLOWING CODES: 2010 CEC, 2010 CBC & NEC 2008 CEC AC SYSTEM SIZE: 12.989 kW AC Q M RANCHO SANTA MARGARITA �tLu� mot cow coi o��� t �vi NOTES: y 1. THIS IS A 14.715 KW SOLAR ELECTRIC SYSTEM- USING (45) SUNPOWER SPR-327NE-WHT-D (327 WATT) PHOTOVOLTAIC MODULES. 2. THIS SYSTEM IS GRID-INTERTIED VIA UL -LISTED POWER CONDITIONING INVERTERS: (1) SUNPOWER SPR -7000m-240 AND (1) SUNPOWER SPR -6000m-240 _ 3.'THIS SYSTEM HAS NO UPS, NO BATTERIES. - 4. THIS IS A'ROOF MOUNTED SYSTEM, ADDING 2.68 LB/SQ FT. - FOLLOWING THE ROOF SLOPE. ROOF IS SPANISH TILE AT 15° PITCH. 5. THE SYSTEMS SQUARE FOOTAGE IS 815 FT'. MODULES HAVE AN AZIMUTH OF 180". _ 6. MODULES ARE 0 DEGREES TILT ABOVE ROOF SLOPE.: ~ 7. BUILDING IS (1) STORIES. • ' �. •8. LAG SCREWS ARE 3/8" X 4" AT 48" O.C. MAX, WITH 2.5" INTO FRAMING. `9. MODULES WILL BE SECURED TO ROOFTOP USING QUICKMOUNT SPANISH: , TILE ROOF HOOKS. 10. ATTACHMENTS WILL BE DOUBLE -FLASHED 11. DESIGNED FOR BASIC WIND SPEED OF 100 MPH. 7 12. VISIBLE EXPOSED CONDUIT SHALL BE PAINTED TO MATCH." 13. MODULE DIMENSIONS ARE 41.2" X 61.4" 14. 'SYSTEM INSTALLATION SHALL BE PER NEC 690 AND D IS SUBJECT TO FIELD INSPECTION BY THE CITY.' 15. PROPER CLEARANCES SHALL BE IN ACCORDANCE'WITH ALL ADOPTED CAL FIRE GUIDELINES.'— i CITY O LA QUII14TA BUILDING & SAFE i Y� 1063103 50 KVA C -Phase `.. DRIVEWAY P W _ High Low 120/220/2 40V FOR �pNSTRUCTION r - DATE BY ` i r EXISTING METER # 1 B4S-109943 ' QPROPOSED BI-DIRECTIONAL METER ' . UPGRADE EXISTING 200A MAIN ` PV Installation K -Company Renova Energy .Cof p California - 2012 North American Board of NABCE:P' .t - • j, ' - "• } • , . - r .. - • k - , '` .+ • • . ' - Drawn By: t +• � .. r ©- STRING #1, SPR 7000m r 'C. L. FDate Drawn: NG - STRI#2, SPR 7000m QRD ESSlO^r Er Lofcc�, .4/25/1349' 4/25/13 - BACKYARD T +. ❑ - STRING #3, SPR 7000m Z Revision No. _ ROPERTYLIN - - t y _� _:._`, _ No.e9093.. _ r - _ EXP. 9/30/13 - 'STRING #4,'SPR 6000m if S t, r ' �J'I ti CPQ \Q y ► J' ; i 9l �fCTRI \E��� }� - . ® .STRING #5,. SPR 6000m • �F CAI Sheet No. � 4fi. ' f` •' .• ^ ,:; -. a "�* ', :. - -i' . .�j _ '.y . '.. . .. ' V `SCi�L,E: 1 = 20 . - -STRING #6,�SPR 6000m 1 " lr. _ 4 SERVICE TO 225A MAIN SERVICE _ - 120/240 VOLT F CHIMNEY' LOCATED ON'EAST EXTERIOR WALL — 4. t t. •. 100 AMP AC DISCONNECT, Q EATON #DG223URB c , L 120/240 VOLT Q >_� LOCATED NEXT TO MAIN PANEL �> a :Q t ao ov, ' 125 AMP AC COMBINER .. SQUARE=D #HOM816L125RB ;� �, F7. M _ J z a . 120/240 VOLT' r.. CV LOCATED IN GARAGE N SUNPOWER 7000 WATT INVERTER. - .. SPR -7000m-240 Q U + 120/240 VOLT ' w ...,LOCATED IN GARAGE Q Z J _ - : SOLAR MODULES • _ + a _ SUNPOWER 6000 WATT INVERTER . Lo r . t • } „ SPR -6000m-240 . L0 rti.j o r o- °� f 120/240 VOLT - .. J4..,: Z { .a..... LOCATED IN GARAGE F- �- - ia ..-., . __.,. �- a ._ ,.. ..-.ri ... .. .J•y - -a ..... .. .'._-•.. a rr.-.. fin•,. .•{F. .. a .. ..-. .�. ... f.. �a .w .- a-.. .U.a. .t - • j, ' - "• } • , . - r .. - • k - , '` .+ • • . ' - Drawn By: t +• � .. r ©- STRING #1, SPR 7000m r 'C. L. FDate Drawn: NG - STRI#2, SPR 7000m QRD ESSlO^r Er Lofcc�, .4/25/1349' 4/25/13 - BACKYARD T +. ❑ - STRING #3, SPR 7000m Z Revision No. _ ROPERTYLIN - - t y _� _:._`, _ No.e9093.. _ r - _ EXP. 9/30/13 - 'STRING #4,'SPR 6000m if S t, r ' �J'I ti CPQ \Q y ► J' ; i 9l �fCTRI \E��� }� - . ® .STRING #5,. SPR 6000m • �F CAI Sheet No. � 4fi. ' f` •' .• ^ ,:; -. a "�* ', :. - -i' . .�j _ '.y . '.. . .. ' V `SCi�L,E: 1 = 20 . - -STRING #6,�SPR 6000m 1 " lr. _ 4 WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUC TERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. OPERATING CURRENT: 17.94 Amps OPERATING VOLTAGE: 357.07 Volts MAXIMUM VOLTAGE: 550.28 Volts SHORT-CIRCUIT CURRENT: 19.38 Amps NOTE: MOUNT ON DC DISCONNECT 1 OF 2 OF SPR -7000m INVERTER WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. MAX AC OPERATING CURRENT: 54.17 Amps OPERATING AC VOLTAGE: 240 Volts NOTE: MOUNT ON AC DISCONNECT COVER AND AC COMBINER COVER 3" THIS PANEL IS FED BY TWO SOURCES: SOLAR PHOTOVOLTAIC SYSTEM ON PREMISES NOTE: MOUNT ON SERVICE PANEL 3" WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, THE NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. NOTE: MOUNT ON INVERTERS WARNING: THIS FACILITY IS EQUIPPED WITH A PHOTOVOLTAIC GENERATOR LOCATED ON THE ROOF AS SHOWN. THE SYSTEM MAY BE DISCONNECTED FROM THE FACILITY PER THE AC DISCONNECT AS SHOWN. SITE PLAN 225A MAIN& PANEL 100A AC DISCONNECT 125 AMP AC COMBINER SUNPOWER 6000W INVERTER SUNPOWER 7000W INVERTER NOTE: MOUNT ON SERVICE PANEL NOTE: RED BACKGROUND WITH WHITE LETTERING 3/8" LETTER HEIGHT WARNING: ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LIN AND LOAD SIDES MAY BE ENERGIZED IN iv THE OPEN POSITION. OPERATING CURRENT: 17.94 Amps OPERATING VOLTAGE: 312.44 Volts MAXIMUM VOLTAGE: 481.5 Volts SHORT-CIRCUIT CURRENT: 19.38 Amps NOTE: MOUNT ON DC DISCONNECT 2 OF 2 OF SPR -6000m INVERTER 3" WARNING: _ ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NOTE: MOUNT ON AC COMBINER AND DISCONNECTS AND SERVICE PANEL 3" WARNING INVERTER CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. NOTE: MOUNT ON AC COMBINER AT SOLAR BREAKERS 3" PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS NOTE: MOUNT ON DISCONNECTS 3" FPHOTOVOLTAIC DISCONNECT BREAKERS LOCATED INSIDE NOTE: MOUNT ON AC COMBINER COVER 3" FPHOTOVOLTAIC DISCONNECT BREAKER 1 OF 2 NOTE: MOUNT ON AC COMBINER NEXT TO 40A SOLAR BREAKER 3" PHOTOVOLTAIC DISCONNECT BREAKER 2 OF 2 NOTE: MOUNT ON AC COMBINER NEXT TO 35A SOLAR BREAKER 3" THE MAIN SERVICE BREAKER HAS BEEN DOWN -SIZED TO 175 AMPS. NO UP-SIZING IS PERMITTED NOTE: MOUNT ON MAIN PANEL AT MAINBREAKER PROJECT SIGNAGE ISCALE: N/A MATERIALS (45) SUNPOWER 327 WATT PHOTOVOLTAIC MODULES #SPR-327NE-WHT-D (1) SUNPOWER SPR -7000m - 7000W, 240 VOLT (1) SUNPOWER SPR -6000m - 6000W, 240 VOLT (1) SQUARE -0 125A LOAD CENTER WITH 10KAIC MAIN CIRCUIT BREAKER, 120/240C, 1PH. 3W. #HOM816L125RB &(1) EATON AC DISCONNECT, 100A NON -FUSIBLE, 2 -POLE #DG223URB (1) MONITOR/PV SUPERVISOR SOLAR PRODUCTION SUMMARY GROSS NAMEPLATE RATING (45 z 327/1000) 14.715 kW . CEC AC SYSTEM SIZE 12.989 kW 29 30 313233 1 34 35 36 37 38 39 40 41 42 43 44 45 N W _*_ E S NOTES+ SOLAR PRODUCTION STATS. SNE- { 2 1 P.V. PLAN NIAt 1 PANEL: AC COMBINER 1 2 3 4 5 6 7 8 9 10 11 12 �13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 313233 1 34 35 36 37 38 39 40 41 42 43 44 45 N W _*_ E S NOTES+ SOLAR PRODUCTION STATS. SNE- { 2 1 P.V. PLAN NIAt 1 PANEL: AC COMBINER PANELVOLTAGE: 240/120 1P,3W CIRCUIT CODE: N: NON -CONTINUOUS H BUS: 125 A L: LONG -CONTINUOUS LOCATION: INSIDE GARAGE R: DEMANDABLE RECEPTACLES V MOUNTING: SURFACE K: KITCHEN AIC RATING: 10,000 CQ G VA LOAD W TYPE I C.B. BUS C.B. TYPE W VA LOAD LOAD DESCRIPTION �O W z LOAD DESCRIPTION x A 8 U N R L I TR I P A B TR I P L R N v A B v 1 3500 Sunpower SPR -7000m Inverter L 40140 12 x Q L 2 3 3500 L x U L 4 5 3000 Sun ower SPR -6000m Inverter L 351 35 1 2 x L Z 6 7 3000 L x E L ti 8 6500 6500 PHASE TOTALS 0 LO J PHASE TOTALS 0 to 'o PHASE TOTALS A+B CONNECTED VA (CODE N): TOTAL PHASE A: 1 6500 CONNECTED VA (CODE L): 13000 L. TOTAL PHASE B: 1 6500 CONNECTED VA (CODE R): 4/25/13 CONNECTED VA (CODE K): TOTAL CONNECTED KVA: 13.0 DEMAND KVA TOTAL ADJUSTED KVA: 13.0 TOTAL PANEL AMPS: 54.17 AMPS W/L CL: NOTES 1. THE PV SOURCE CIRCUIT IS POSITIVELY GROUNDED. 2. WIRE AND SIZES ARE AS INDICATED OR LARGER. 3. ALL EQUIPMENT IS BONDED BY MECHANICAL MEANS OR BY A GROUNDING CONDUCTOR. 4. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE #8 AWG COPPER GROUND WIRE AND BONDED TO THE EXISTING GROUNDING ELECTRODE SYSTEM. 5. CHANGES TO DESIGN NEED PRIOR ENGINEER APPROVAL. 6. ALL CONDUIT RUNS SHALL BE SUPPORTED IN ACCORDANCE WITH CODE WITH A MINIMUM OF 0.5 TO 3.5 INCH STANDOFF FROM THE FINISHED ROOFTOP SURFACE. CEC Table 310.15(B)(2)(c) 7. ALL EXTERIOR CONDUIT AND BOXES SHALL BE RAIN -TIGHT AND SHALL USE OUTDOOR COMPRESSION FITTINGS LISTED FOR USE IN WET LOCATIONS(OUTDOOR RAINTIGHT). CEC 314.15 SAFEGUARDS • SOLAR BREAKER SHALL BE LISTED FOR USE IN EXISTING MAIN PANEL.. ACCEPTED BREAKER REPLACEMENTS ARE EATON, SQUARE -D & GE. * ALL JUNCTION BOXES SHALL BE NEMA OUTDOOR/RAINTIGHT RATED ' WILEY CABLE CLIPS ' EMT CONDUIT WHERE EXPOSED / ALL METAL CONDUIT -NO SET SCREWS ' SERIES CIRCUITS FUSED AT 20 AMPS DC " ALL EQUIPMENT TO BE LABELED " ADD COMBINER / JUNCTION BOX AS NEEDED • BLOCKING DIODE INTERNAL IN EACH MODULE CITY OF ILA QUINTA BUILDING & SAFETI Y DEPT. A FOR CONSTRUCTION DATE W SUPPORT SYSTEM • WIND LOAD: BASIC WIND SPEED (3 -SECOND GUST, 100 MPH) • WIND EXPOSURE C ' CONDUIT SUPPORT BY COOPER/BEELINE OR CADDY ' VISIBLE AND ACCESSIBLE 'SOLARMOUNT-1 RACKING SYSTEM, LAG BOLTED DIRECTLY INTO RAFTERS. 'GROUND FAULT PROTECTION DEVICE BUILT INTERNALLY INTO SUNPOWER INVERTERS 'MODULE GROUNDING PERFORMED WITH ILSCO GBL-4DB LUGS WITH #8 SOLID BARE COPPER AND WEEB CONNECTIONS. 'ALL NEUTRAL TO GROUND CONNECTIONS ARE TO OCCUR IN MAIN PANEL LOCATION '1" EMT MINIMUM " JUNCTION BOX/ COMBINER BOX ENTRY TO BE COMPRESSION FITTING i "NABCEP I<<41M:1211111129lf PV Installation Company Renova Energy Corp. California - 2012 North American Board of - NABCEP Revision No '2 Sheet No E.1• Q H V CQ G Q W z LO J Q N c N U 0 Q U Q U Z Ir Z C} G Lo E ti W z 0 LO J 0 to 'o a Drawn By: C. L. Date Drawn: 4/25/13 Revision No '2 Sheet No E.1• MODULES TO SUNPOWER 7000W INVERTER 3 STRINGS X 8 MODULES = 24 MODULES MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low'C [via www.solarabcs.org]) x T coefV)) X # modules in series MAX VOLTAGE DC= (64.9 +((25'C - 3'C) x.1766)) X 8 modules in series = 550.28 VOLTS 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 10.08 AMPS FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR 8 44'C AMBIENT TEMP. PER SOLARABCS.ORG #8 WIRE= 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS , 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK MODULES TO SUNPOWER 6000W INVERTER 3 STRINGS X 7 MODULES = 21 MODULES MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low'C [via www.solarabcs.org]) x T coefV)) X # modules in series MAX VOLTAGE DC= (64.9 +((25'C - 31C) x.1766)) X 7 modules in series = 481.5 VOLTS 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.81 = 10.08 AMPS FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABCS.ORG #8 WIRE = 55 AMPS X .581PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 1" EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK SUNPOWER 7000W INVERTER TO AC COMBINER 7000W / 240 VOLT = 29.17A X 1.25[PER NEC 215.2(A)1] = 36.46A (40 AMP SOLAR BREAKER) . AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR 8 44'C AMBIENT TEMP. PER SOLARABCS.( #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)] = 45.1 AMPS 45,1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 45.1 AMPS > 36.46 AMPS = OK (3) 98 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK SUNPOWER 6000W INVERTER TO AC COMBINER . 6000W / 240 VOLT = 25A X 1.25[PER NEC 215.2(A)1] = 31.25A (35 AMP SOLAR BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABI #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)] = 45.1 AMPS 45.1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 45.1 AMPS > 31.25 = OK (3) #8 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK CITY OF LA QUINTA BUILDING & SAFETY DEP- VE FOR CONSTRUCTION AC COMBINER TO MAIN PANEL 40A + 35A = 75 AMPS TOTAL (75 AMP SOLAR.BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABCS.ORG #4 THWN-2 = 95 AMPS x .82[PER NEC TABLE 690.31(C)] = 77.9 AMPS 77.9 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 77.9 AMPS > 75 = OK (3) #4 THWN-2 AWG WIRE, (3) #8 THWN-2 GROUND 6.46 AMPS EACH CIRCUIT X 1.56[PER'NEC 690.81= 10.08 AMPS _ _ 1.1/4" EMT @ 40%FILL PER NEC TABLE C.1 = (7) #4 THWN-2 WIRES = OK MAIN PANEL CONNECTION CALCULATION #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2Xc) & PER NEC TABLE 690.31(c)] = 31.9 AMPS UPGRADE EXISTING 200 AMP MAIN SERVICE TO 225 MAIN SERVICE 31.9 AMPS X .50[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 15.95 AMPS > 10.08 AMPS = OK DOWNSIZE EXISTING 200 AMP MAIN BREAKER TO 175 MAIN BREAKER 6 STRINGS= (12)#8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 120% OF 225 AMP BUSS" ALLOWABLE BACKFED AMPS [PER NEC 690.64(B)(2)) = 270 1 1/4" EMT @ 40%FILL PER NEC TABLE CA = (16) #8 THWN-2 WIRES = O'K 270 AMP 175 AMP MAIN BREAKER = 95 TOTAL ALLOWABLE'. 75 AMP SOLAR BREAKER < 95 AMPS = OK ' CALCULATIONS LK. ro c Qo > & CO C N N M V a) 0) 0�U rnr? r a`>a �Go( CWNa) MM a) o���= aDO E.,r a) m [ CIL i c C Mft PV Installation Company Renova Energy Corp. California - 2012 Menerqy BY -10- a 2 U N �O CL 2 Q . �NN 1.1. a Q � W Z LO J N CO (� U 0 Q Q U U QI- } Ir Z Lo D L 0 0) J Drawn By: C. L. Date Drawn: 4/25/13 Revision No. 2 Sheet No. E:2 Solar System Size: 14.715 kW DC SOLAR ARRAY CEC System Size: 12.989 kW AC (24) SUNPOWER 327 WATT DC DISCONNECT FUSED AT 20 AMPS (2)#8THWN-2 PHOTOVOLTAIC MODULES (1) #8 THWN-2 NEUTRAL #SPR-327NE-WHT-D (1) #8 THWN-2 GEC TO IID MODULE PTC RATING:301AW 6)#8THWN-2 (1) #8 THWN-2 EGC (3 STRINGS OF 8 MODULES) 1 #8 THWN-2 EGC EMT 1" EMT UPGRADE EXISTING 200 AMP MAIN 1102521 SUNPOWER - SERVICE TO 225 AMP MAIN SERVICE KV. Phase SPR -7000m 240V 2P Hi 240/120 VOLT, 2 POLE High 7.2 kV LOCATED ON EAST EXTERIOR WALL Low 120/240 V OOOOOOOO Underground Transformer 0 0 00 0O Q0 METER # 1 B4S-109943 00000000 SOLAR BREAKERS SUITABLE FOR DISCONNECTING PROPOSED BI-DIRECTIONAL LOCATED IN GARAGE . MEANS PER NEC 690.14 AND 690.17 DOWNSIZE EXISTING MAIN BREAKER TO 17 OA METER # ALL WIRING BETWEEN MODULES SHALL BE TYPE USE -2 IF EXPOSED ALL CONDUIT SHALL BE 1" EMT OR LARGER. - (2) #4 THWN-2 (1)#4THWN-2 NEUTRAL 75 AMP SOLAR ALL CONDUIT SHALL BE BONDED. (2) #8 THWN-2 GEC BREAKER ALL CONDUIT SHALL BE SUPPORTED BY RUBBER (12) #8 THWN•2 N-2 EGC t;/q8 (1) #8 THWN-2 EGC 1 1/4" EMT N BAR PYRAMID SUPPORTS E STEEL CITY 6"X6"X4" OUTDOOR JUNCTION BOXES SHALL BE USED AS NEEDED. �� G BAR ALL CONDUIT SHALL HAVE PLASTIC STRAIN RELIEF CONNECTORS TO PROTECT WIRES. _ 35A 20A LIFER. GROUND (2) #4 THWN-2 TO 0000000 12"x42"x4" STEEL ouT000R JUNCTION BOX 100 AMP AC DISCONNECT 75 AMP 2 -POLE SOLAR BREAKER 0000000 A 125 AMP EATON 3URB 0000000 SUNPOWER AC COMBINER SQUARE -D #40DV222P 2V, LOCATED NEXT TO PANEL SPR -6000m 0VP 240V, 2P LOCATED IN GARAGE (1) #4 THWN-2 NEUTRAL (6)#8THWN-2 (1) #8 THWN-2 GEC SOLAR ARRAY 1 #8THWN-2 EGC V Ems.1 . #8 THWN-2 EGC (2)#4THWN-2 GEC CONNECTED TO MAIN - (21) SUNPOWER 327 WATT ^, - (1 #4 THWN-2 NEUTRAL PANEL GND PHOTOVOLTAIC MODULES 2 #8 THWN-2 GEC 0 #8THWN-2EGC 'EMT ENTRY TO MAIN PANEL #SPR-327NE-WHT-D LOCATED IN GARAGE., (2)#8THWN-2 NEUTRAL 11/4"EMT TO BE DETERMINED IN FIELD MODULE PTC RATING:301AW FUSEDAT(1)#8THWN-2 (1)#8 THWN-2 GEC MONITOR/ PV SUPERVISOR (3 STRINGS OF,8 MODULES) (1) #8 THWN-2 EGC INTERNET 1" EMT 120 VOLT 'EGC = EQUIPMENT GROUNDING CONDUCTOR GROUNDING ELECTRODE CONDUCTOR SINGLE LINE DIAGRAM . SCALE:I NA nt- 11I0I_I IITQ A!- t-I1T)nl IITQ MODULES TO SUNPOWER 7000W INVERTER 3 STRINGS X 8 MODULES = 24 MODULES MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low'C [via www.solarabcs.org]) x T coefV)) X # modules in series MAX VOLTAGE DC= (64.9 +((25'C - 3'C) x.1766)) X 8 modules in series = 550.28 VOLTS 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.8] = 10.08 AMPS FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR 8 44'C AMBIENT TEMP. PER SOLARABCS.ORG #8 WIRE= 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS , 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK MODULES TO SUNPOWER 6000W INVERTER 3 STRINGS X 7 MODULES = 21 MODULES MAX VOLTAGE DC = (MODULE Voc + ((25°C - Temp Record Low'C [via www.solarabcs.org]) x T coefV)) X # modules in series MAX VOLTAGE DC= (64.9 +((25'C - 31C) x.1766)) X 7 modules in series = 481.5 VOLTS 6.46 AMPS EACH CIRCUIT X 1.56[PER NEC 690.81 = 10.08 AMPS FUSED AT 20 AMPS EACH CIRCUIT LOCATED AT INVERTER DC CONDUIT SHALL BE MOUNTED 1/2" TO 3 1/2" ABOVE ROOFTOP SURFACE. ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABCS.ORG #8 WIRE = 55 AMPS X .581PER NEC TABLE NEC TABLE 310.15(B)(2)(c) & PER NEC TABLE 690.31(c)] = 31.9 AMPS 31.9 AMPS X .80[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 25.52 AMPS > 10.08 AMPS = OK 3 STRINGS= (6) #8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 1" EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK SUNPOWER 7000W INVERTER TO AC COMBINER 7000W / 240 VOLT = 29.17A X 1.25[PER NEC 215.2(A)1] = 36.46A (40 AMP SOLAR BREAKER) . AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR 8 44'C AMBIENT TEMP. PER SOLARABCS.( #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)] = 45.1 AMPS 45,1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 45.1 AMPS > 36.46 AMPS = OK (3) 98 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK SUNPOWER 6000W INVERTER TO AC COMBINER . 6000W / 240 VOLT = 25A X 1.25[PER NEC 215.2(A)1] = 31.25A (35 AMP SOLAR BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABI #8 THWN-2 = 55 AMPS x .82[PER NEC TABLE 690.31(C)] = 45.1 AMPS 45.1 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 45.1 AMPS > 31.25 = OK (3) #8 THWN-2 AWG WIRE, (2) #8 THWN-2 GROUND V EMT @ 40% FILL PER NEC TABLE CA = (9) #8 THWN-2 WIRES = OK CITY OF LA QUINTA BUILDING & SAFETY DEP- VE FOR CONSTRUCTION AC COMBINER TO MAIN PANEL 40A + 35A = 75 AMPS TOTAL (75 AMP SOLAR.BREAKER) AC CONDUIT SHALL BE MOUNTED INSIDE GARAGE ENGINEERED FOR 90'C TEMP. RATING OF CONDUCTOR & 44'C AMBIENT TEMP. PER SOLARABCS.ORG #4 THWN-2 = 95 AMPS x .82[PER NEC TABLE 690.31(C)] = 77.9 AMPS 77.9 AMPS X 1.0[CONDUIT FILL PER NEC TABLE310.15(BX2)(a)] = 77.9 AMPS > 75 = OK (3) #4 THWN-2 AWG WIRE, (3) #8 THWN-2 GROUND 6.46 AMPS EACH CIRCUIT X 1.56[PER'NEC 690.81= 10.08 AMPS _ _ 1.1/4" EMT @ 40%FILL PER NEC TABLE C.1 = (7) #4 THWN-2 WIRES = OK MAIN PANEL CONNECTION CALCULATION #8 WIRE = 55 AMPS X .58[PER NEC TABLE NEC TABLE 310.15(B)(2Xc) & PER NEC TABLE 690.31(c)] = 31.9 AMPS UPGRADE EXISTING 200 AMP MAIN SERVICE TO 225 MAIN SERVICE 31.9 AMPS X .50[CONDUIT FILL PER NEC TABLE 310.15(B)(2)(a)] = 15.95 AMPS > 10.08 AMPS = OK DOWNSIZE EXISTING 200 AMP MAIN BREAKER TO 175 MAIN BREAKER 6 STRINGS= (12)#8 THWN-2 AWG WIRE, (1) #8 THWN-2 GROUND 120% OF 225 AMP BUSS" ALLOWABLE BACKFED AMPS [PER NEC 690.64(B)(2)) = 270 1 1/4" EMT @ 40%FILL PER NEC TABLE CA = (16) #8 THWN-2 WIRES = O'K 270 AMP 175 AMP MAIN BREAKER = 95 TOTAL ALLOWABLE'. 75 AMP SOLAR BREAKER < 95 AMPS = OK ' CALCULATIONS LK. ro c Qo > & CO C N N M V a) 0) 0�U rnr? r a`>a �Go( CWNa) MM a) o���= aDO E.,r a) m [ CIL i c C Mft PV Installation Company Renova Energy Corp. California - 2012 Menerqy BY -10- a 2 U N �O CL 2 Q . �NN 1.1. a Q � W Z LO J N CO (� U 0 Q Q U U QI- } Ir Z Lo D L 0 0) J Drawn By: C. L. Date Drawn: 4/25/13 Revision No. 2 Sheet No. E:2 Y�`�A. 3 I ♦4 .- 1. b k r t }i y •� ^RV�. � ' .k'l�� n+ c.:11�Y:lllf' Y1. ..,,.. 9w' ,, '� � { F. rk f, A o Project Name . — - a o o W T01�1PJIY M ARCHULETA renova, Z ? g Renova Energy Corp 79575 RANCHO SANTA MARGARITA 75-181 Mediterranean Ave. co Palm Desert, CA 92260 -3413 LA QUINTA, CA 92253 (7ors License Contractor's License #910836 ' THE WORLD'S STANDARD FOR SOLAR TM E z SERIES SunPowerT' E20 Solar Panels provide today's highest efficiency and performance. Powered by SunPower MaxeonTPA cell technology, the E20 series provides panel conversion efficiencies of up to 20.1 %. The E20's low voltage temperature coefficient, anti -reflective glass and exceptional low -light performance attributes provide outstanding energy delivery per peak power watt. SUNPOWER'S HIGH EFFICIENCY ADVANTAGE 20% 15% 10% 5% SERIES SERIES SERIES sunpowercorp.com C (@ us MODEL: SPR-327NE-WHT-D Peak Power (+5/-3*/0) Pmax 327 W Cell Efficiency ;, n 22.5 t, Panel Efficiency t h 20.1 Rated VoltageVmpP Weight 41.0 lbs (18.6 kg) 54.7 V Rated CurrentImpp 5.98 A Open Circuit Voltage Vac 64.9 V Short Circuit Curreht i Isc 6.46 A l Maximum System Voltage LIL 600 V Temperature Coefficients Power (P) - 0.38%/K L Voltage (Vac) -176.6mV/K Current (Isc) 3.5mA/K NOCT 45* C +/- 2* C Series Fuse Rating 20A Grounding i' Positive grounding not required Solar Cells ll 96 SunPower Maxeon' cells Front Glass j,' High -transmission tempered glass with anti -reflective (AR) coating Junction Box IP -65 rated with 3 bypass diodes Dimensions: 32 x 155 x 128 mm Output Cables 1000 mm cables / MultiContact (MC4) connectors Frame ji Anodized aluminum alloy type 6063 (black) Weight 41.0 lbs (18.6 kg) MM (A) - MOUNTING HOLES (B) - GROUNDING HOLES (IN) 12X 06.6 [.261 1 O 04.2 (.17] [-Tom w/m= of sD_' f 1000 W/ I Boo w/m= _ � I I 500 w/ml i Temperature -40* F to +185* F (-'40* C to + BY C) Max load 113 psf 550 kg/m2 (5400 Pa), front (e.g. snow) w/specified mounting configurations 50 psf 245 kg /M2 (2400 Pa) front and back (e.g. wind) Impact Resistance Hail: (25 mm) at 51 mph (23 m/s) . .... ... ... ... WARRANTIES AND GERTIFIC�ATIONS Warranties 25 -year limited power warranty 10 -year limited product warranty Certifications Tested to LIL 1703. Class.0 Fire Rating • 2X 11.0[.431 zxsn[zz.7o] lBo[7.o7] - 30[1.181 322[12.69] 1 4X 230.8 (9.091 BR BRIH m c . END N i 1559[61.39] • 46[1.811 —� �— (A) 915[36.021 1200(47.24] 12(A 1 1535 [,60.451 Please read safety and installation instructioni's before using this product, visit sunpower-corp.com for more details. 02011 SunPower Corporafion. SUNPOWER, the SunPower logo, and THE WORLD'S STANDARD FOR SOLAR, and MAXEON arehadamarks or raglstered hadsunowercoramarks P p'com of SunPower corporation In the Us and other countries as well. AO Rights Reserved. Specifications included in this datosheet one subject to change without notice. Document #001.65484 Rev*B / LTR_EN. )r rs 11316 f l o k�v 0 BENEFITS Relicble and Robust'Desig- Proven track record for durability and longevity `Effective Power Range Enables most systems to Use a single inverter rather -than multiple units . Commercial Use Flexible AC voltage output and scalable building blocks create an easy "solution for commercial applications High Efficiency Weighted CECefficiency of at least 9.5.5% -and, peak efficiency of at least 96.5% Reduced Installation .Cost Integrated DC disconnect with fuses lowers material costs and labor requirements Attrcctive Aesthetics Integrated disconnect eliminates need for visible conduits to inverter- .7V, , SPR -5000m, -6000m,, -7000m and -8000m SunPower SPR -5000m, -6000m, -7000m and -8000m inverters offer superior reliability :and performance and can be easily integrated into res-dential or commercial installations. All models are backed by a 10 -year warranty. sunpowercorp.com 1-800-SUNPOWER t BENEFITS Reliable and Robust 'Design, Proven -track record "for durability and longevity Effective Power Range e Enables most systems to use a single inverter rather than multiple units Commercial Use Flexible AC voltage output and scalable building blocks create an easy solution for commercial applications High.Efficiency Weighted CEC efficiency. of at . least 95.5% and peak.efficiency of at least 96.5% Reduced Installation Cost Integrated DC disconnect with fuses lowers material costs and labor requirements Attractive Aesthetics Integrated disconnect eliminates need for visible conduits to'inverter SunPower SPR -5000m, -6000m, -7000m and -8000m inverters offer superior reliability and performance and can be easily integrated into residential or commercial installations. All models are backed by a 10 -year warranty. sunpowercorp.com F 1-800-SUNPOWER k Product Data Sheet r �... _ D223NRB SWITCH FUSIBLE GD 240V 100A 2P NEMA3R $ , ' .. � • by Schneider Elcctrlc 1 ~� N List Price $480.00 USD i ? Availability Stock Item: This item is normally stocked in our distribution facility. pi *- - ; Technical Characteristics Terminal Type Lugs , Type of Duty: General Duty - - Maximum Voltage Rating - 240VAC S Wire Size , #12 to #1/0 AWG(AI) =•#14 to #1/0 AWG(Cu) Depth 6.50 Inches Height t 17.50 In • " Width 8.50 Inches e Action i Single Throw - Ampere Rating' 100A_ Approvals UL Listed File: E2875 m T Enclosure Rating NEMA3R'4 Enclosure Type—Rainproof and SleeUlce proof (Indoor/Outdoor) - ------ 1-7 ---- --------- _. -----------+ -- ---- --- ----------------- ----- ---- ---- ---- --------------- — s Enclosure Material Galvannealed Steel Factory Installed Neutral _ ' Yes - Fuse Type ( Cartridge (Clas§'H, K or R) Disconnect Type fusible - - Short Circuit Current Rating 100kA (max. depending on fuse ,type) •: ` Mounting Type" + Surface . --------------------------------------------- -------------------------------------------- -- -------- - -- --------- -- ----- Number of Poles.. 2-Pole Shipping and Ordering- Category,. 00106 - Safety Switch, General Duty, 30 - 200 Amp, NEMA3R Discount Schedule,. DPA e GTIN i.. 00785901460701 t Package Quantity - - .�..�. Weight.15.46 lbs: ' Availability Codes " Stock Item: This item is normally stocked in our distribution facility. - ------- ----------------------------------- ---------------- ---- -- - --- -- -------------- ------------------------------------------- Retumability i r Y Country of Origin US As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document: Generated: 11/17/201117:12:45 i O 2011 Schneider flectric: All rights reserved1.ScW-1Eeider , lec.tric 11 Product Data Sheet H0M81&125RB LOADCTR HOM MLO 240V.125A 1 PH 8SP NEMA3R - - SQUAE by Schneider ei.ctric List Price ' $248.00 USD -------------------------------------------------------------- ------------------------------------- Availability Stock Item: This item is normally stocked in our distribution facility. Technical CharaYteristics Ampere Rating 125A y Bus Material Tin Plated Aluminum Enclosure Type Outdoor/Rainproof'-------------------s - - Box Number 3R r Application Designed to meet residential, commercial and industrial requirements to protect electrical systems, equipment and people. Enclosure Rating NEMA 3R Grounding Bar Order separately Maximum Single Pole:Circuits 16 Short Circuit Current ?ating ------------------------- 10kA� Maximum Tandem Circuit Breakers ------------------------ 8 Approvals UL Listed Main Type Convertible - Factory installed main lugs Cover Type Combination Flush/Surface Marketing Trade Nams Homeline •--- ------------ ------------------------------- f T______________ ----------------------------- ------- --------- Phase ------------------------------------------------------------------ 1 -Phase - Height 18.92 Inches t Spaces -------------------------------------------------------------------------------------------- 8 { =--------- ---------------------------------------------------- ---------- --------- Voltage Rating --_^ 120/240VAC Wire Size #6 to #2/0 AWG(AI/Cu) Wiring Configuration.. 3 -Wire --------- --------------------------------------------------------------------------------------------------=-------------------------------------------------- Depth `" ------------------- 4.52 Inches Width 14.75 Inches Shipping and Ordering Category 00,149 -Load Centers, NEMA1 & 3R, 2 - 8 Circuits, Type HOM Discount Schedule DE3C --------------------------------------------------------------- GTIN r — ------ _---=------- - , ; -------- ----------- -------------- ,--------------------------- ------ --------- 00785901824060 Package Quantity 1 Weight :. 20.6 lbs. - Availability Code i Stock Item: This item is normally stocked in our distribution facility. ` Returnability Y Country. of Origin _ US .. ----- -------------------j------------------------------- - - -w---------------------------------t Generated: 03/07/201: 22:55:09 O 2013 Schneider Elewne. All rights reserved. Schneider . VElectric January 20, 2011 UnRac 1411 Broadway Boulevard NE Albuquerque, New Mexico 87102-1545. , TEL: (505) 242-6411 - FAX: (505) 242-6412 STRU(TURALENGINEERS Attn.: Engineering Department, ' Re: Engineering Certification for UniRac's SolarMount Code -Complaint Installation Manual. 227.3 PZSE, Inc. Structural Engineers has reviewed UniRac's "SolarMount Code -Complaint Installation Manual 227.3" published October 2010 and specifically "Part I. Procedure to Determine the Design Wind Load", and "Part H: Procedure to Select Rail Span and Rail Type". The procedures are used to determine the calculation of the design wind force, load combinations, applied loading and rail selection. All information, data and analysis contained within the Installation Manual are based on, and comply with the following: L' 2009 International Building Code, by International Code Council, Inc., 2009 2. 2010 California Building Code • by California Building Standards Commission, 2011 ; 3. Aluminum Desijan Manual: Specifications and Guidelines for Aluminum Structures, by The Aluminum Association, 2005 This letter certifies that the structural calculations contained within UniRac's "SolarMount Code -Complaint Installation Manual 227.3 are in compliance with the above Codes. If yohave any questions on the above, do not hesitate to call. Since ely, Paul �(6chei. SE - President 8137 Sunset Avenue, Suite 120 • Fair Oaks, CA 95628 0 916.961.3960 + 916.761.3965f'- WWW.PZSr.COM SOLARMOUNT� PV's most versatile mounting system SolarMount is the most versatile PV mounting rail system on the market today. We've engineered installer -friendly components for maximum flexibility, allowing you to solve virtually any PV mounting challenge. The universal SolarMount rail system has three options which can be assembled into a wide variety of PV mounting structures to accommodate anyjob site. Unirac provides a technical support system complete with installation and code compliance documentation, an on-line estimator and design assistance to help you solve the toughest challenges. 013 •moN I IRA[ 1010 Bright Thinking in Solar Visit us online at www.unirac.com SOLARMOUNT° RAIL OPTIONS PV's most versatile mounting system SolarMount° HD ^ HD (heavy duty) rail adds the SolarMount advantage to PV Pole'rops•, U-LAs (see separate data sheets), and custom applications that require long spans. MODULE MOUNTING Assembly Sequence Is.Your Choice Top Mounting Clamps Ideal for flush mount applica- tions, such as residential rooftops, where it is most convenient to secure footings and rails before installing modules, top mounting clamps securely grip any point of the module frame, freeing you from the constraints of module mounting holes. Standard Solarlvount" Standard rail gives you ultimate flexibility, including bottom mounting and tilt -up options. Bottom Mounting Clips _. Use bottom mounting clips' �'``'°'>• (standard and HD rail only) whenever you prefer to -•� preassemble the array using module mounting holes. Simply fit the clip into its rail slot over the mounting bolt for a secure connection. Adjust the clip position anywhere along the rail slot. J ATTACHMENT OPTIONS Flexible Components Speed Installation Standoffs Use standoffs whenever Dashed installations are required, on tile roofs, for example. Two- piece aluminum standoff allow precise place- ment of a Dashing over a secured base prior to the installation of the standoff itself. • All standoff types come in four standard heights: 3, q, 6, and 7 inches. Appropriate Flashings are available. r Serrated L -feet Standard for ground mount installations on residential and commercial rooftops,use L -feet • t alone above asphalt composition shingles or in conjunction with Dat lop standoffs. Mount standard or light rails. Configure to either of two rail heights, one promoting air flow for cooling, the other offering close -to -the -roof aesthetics Strut -in -Tube Style Legs • Quickly set the precise tilt angle required. Styles are available for high profile (i or z legs per rail) and low profile installations. • Each series offers three leg lengths so that you p can adjust to exactly the tilt angle you want— up to a maximum of 6o degrees—without cutting and drilling at the jobsite. t FastFoot- -� The FastFoot- attachment features Eco -Fasten technology by the Alpine Snow Guard Company, allowing attachments to metal, concrete and wood decks without compromising the integrity of the roof. / Tile Hook [ Made from cast aluminum, the tile hook attachment provides SolarMount with a cost-effective solution for barrel or Spanish tile roofs. All required lag bolts and hardware are included. Refer to the tile hook engineering data fur max load capabilities. KEY BENEFITS of SolarMount® Rail Maximum flexibility Flush, high-profile or low -profile configurations Roof or ground mount Pitched or flat roof Ease of installation Installer -friendly components Minimized penetration with longer attachment spans than competitive products Designed with customer input Grounding and wire management options Complete technical support Installation and code compliance documentation Online estimator Person-to-person customer service Core component for Unirac mounting solutions Three rail options to accommodate anyjob site Incorporated into other, major product lines an UNIRAC Bright Thinking in Solar Bright Thinking in Solar Component Specifications 6o6i-T6 and 6063-T5 • SolarMount ballast frame 6105-T5 aluminum extrusion • SolarMount° rails • Mounting clips and, clamps Tilt legs and L -feet Two-piece standoffs Severe Condition 4 (very severe) zinc -plated welded steel • One-piece standoffs 18-8 stainless steel • Fasteners M�� Mm.mUNIRAC' Bright Thinking in Solar Code Compliant The SolarMount® system is PE certified. Call Unirac for documentation applicable to your building code Warranty SolarMount° is covered by a 10 -year limited product warranty and a 5 -year limited finish warranty. For complete warranties, download any SolarMount® installation manual from our web site. Visit us online at www.unirac.com m "SOLARMoumt Technical... - - ::onUNIRAC ` - A HILTI GROUP COMPANY { SolarMount Technical Datashe_et Pub 110818-1td V1.0 August 2011 . SolarMount Module Connection Hardware...:.....:.......::.........................................:..... 1 Bottom Up Module Clip s -Mid Clamp ..............•......................................................... ........... .......2 EridClamp......................................................................................:..........................:...2 SolarMount Beam.Connection Hardware......................................................:..............3 L -Foot ..SolarMount Beams - .4 ..............................................................:....................................... � F ' SolarMount Module Connection. Hardware i f SolarMount Bottom Up Module Clip Part No. 302000C asher, , Bottom Up Clip material: One of the following extruded aluminum Bottomut (h ddense _ alloys: 6005-T5, 6105-T5, 6061-T6 Up Clipo Ultimate tensile: 38ksi, Yield: 35 ksi <� a Finish: Clear Anodized Bottom Up Clip weight: —0.031 lbs (14g) ' Beam ' 1 ' •' � t Ate,., ''Bolt Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents Assemble with one'/<" -20 ASTM F593 bolt, one'/<" -20 ASTM F594 serrated flange nut, and one '/4" flat washer Use anti -seize and tighten to 10 ft -lbs of torque <<• ` Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- ' ,. party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam a *,*NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut U E. Y Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 1566 (6967) 686(3052)_ 2.28 1038 (4615) 0.662 Transverse, Xt 1128 (5019) 329 (1463) 3.43 - 497 (221.3) 0.441 Sliding, Zi - , . 66 (292) 27(119). 1 2.44 `41 (181)1 0.619 TM 1, •F, Dimensions specified in inches unless noted . ' 0 i' SolarMount Mid Clamp Part No. 302101 C, 302101 D, 302103C, 302104D, 30210513,3021061) LOO USTANCE EEYWEEN MEIOUlfS ; 1 Y r Dimensions specified in inches unless noted SolarMount End Clamp Part No. 302001C, 3C2002C, 302002D, 302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C 1 11 v t Serrated S. . Flange Nut t eea, Y , 4 1� Is i - ` N©191HJh] McIff Fr VANES i_ Dimensions speci - d 0 an UNIRAC A HIUI GROUP COMPANY F • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) .. • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac W-20 T -bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N)' Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, X± 1194 (5312) 490 (2179) 1 2.44 1 741 (3295)l 0.620 Clamp • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: —0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated Assemble with one Unirac W-20 T -bolt and one W-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) - Resistance Factor, m Tension, Y+:� 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, -Z± 63 (279) :14 (61) 4.58 21 (92) 0.330; Sliding, X± 142 (630) 1 59(2-11) 1 2.72 79 (349) 0.555 ,1 SolarMount Beam Connection Hardware SolarMount L -Foot Part No. 304000C, 304000D Y L►X 1 �I� aat 3X "T FOP. Kaowuffi 1� 201 Dimensions specified in inches unless noted m :°:°UNI RAC A HILTI GROUP COMPANY • L -Foot material: One of the following extruded aluminum alloys: 6005- T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • L -Foot weight: varies based on height: -0.215 lbs (98g) • Allowable and design loads are valid when components are assembled.with SolarMount series beams according to authorized Jolt UNIRAC documents L -Foot For the beam to L -Foot connection: ' • Assemble with one ASTM F593'/e,°-16 hex head screw and one ASTM F594'/a'serrated flange nut • Use anti -seize and tighten to 30 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory NOTE: Loads are given for the L -Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Sliding, Zt 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse, Xt 486 (2162) 213 (949) 2.28 323 (1436) 0.664 D I:IUNIRAC A HILTI GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D 310208C,310208C-B,310240C,310240C-B,310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus (X -Axis) in' 0.353 0.898 Section Modulus (Y -Axis) in 0.113 0.221 Moment of Inertia (X -Axis) in 0.464 1.450 Moment of Inertia (Y -Axis) in 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 SLOT FOR T -BOLT ^" 14" HEX HEAD SCR 2X SLOT FOR BOTTOM CLIP SLOT FO 3/8" HEX BOL .38, .7 Y L- i�. X SolarMount Beam SLOT FOR T -BOLT OR !/4" HEX HEAD SCREW SLOT FOR BOTTOM CLIP " SLOT FOR HEX BOLT 1.7z8—� 11 7 3.000 l.zo7 Y ��1.875 Lo- X SolarMount HD Beam Dimensions specified in inches unless noted Quick Hook USA"" -Curved Tile Mount I 61MCTH .29--{� T. 6.57 1.89 1 2.21 4.56 —L 3/32" HEX DRIVE ON SET SCREW 1.50 0 0 0 SLIDE TO DESIRED O O LOCATION 0 0 75 ---- _r_JBOTH SIDES OF SLOT SERRATED 2.50 0.39 6.27 �-- 6.00 --� ITEM. NO. DESCRIPTION 1 BASE PLATE, QUICK HOOK USA, 6" WIDE- 6063-T6, MILL 2 LAG SCREW, HEX HEAD, 5/16"x 3-1/2", 18-8SS 3 QUICK HOOK USA, VERTICAL, 6061-T6, MILL 4 SET SCREW, HEX SOCKET, 10-32X5/8", 18-8 SS 5 SUBFLASHING, QUICK HOOK USA V2-6" BASE, 9" X 14" X .032" -3003 -MILL LIQ PR60RM 110N COMAN f1605 G6 SOLEPROPI¢ OOWCK uO11M N. AM'PBROOUCIIONN PAK OR AS NHWE N'RMN LIQ -TW PERSBHON OF DUCK NOMI N O PROI®REO. QTY. 1' 2 1 4 I I I I I/ 2 Quick Mount PVR TITLE: 1 QMCTH: QUICK HOOK USA- 1� CURVED TILE MOUNT UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV 1 DIMENSIONS ARE IN INCHES TOLERANCES: A DATE 2/5/2013 3 FRACTIONAL. III DO NOT SCALE DRAWING TWOPUCEDECIMAL :.IB THREE PUCE DECIMAL t.l SCALE:18 WEIGHT:IM SHffTIOF2 Quick •• Average Ultimate Load Capacities (lbf) in Douglas Fir Configuration Source Document Pullout - Compression Shear Parallel to Shear Perpendicular ° Rafter to Rafter Centered: All base plate sizes with hook positioned AME Report #112640C "Quick Hook USA -Flat Tile 876 685 1058 583 directly over the lag screws (see Appendix A & B of Mount" with 1.5 Base Plate ' referenced report for test setup) - ' This report shows results for Quick Hook USA, both Flat and Curved Tile models, when the hook is posi- tioned directly over the lag screws Offset 4.6" Base Plate: 4.5" wide base plate with AME Report #112640C "Quick Hook USA -Curved Tile 1084 712 1219 532 hook positioned at opposite end of base plate from lag Mount with 4.5" Base Plate , screws (see Appendix A & B of referenced report for test setup)' - This report shows results for our Quick Hook USA- Flat Tile Mount - Offset 6" Base Plate: 6" wide base plate with hook AME Report #112640C "Quick Hock USA -Curved Tile 1246 ° 692 1341 584 positioned at opposite end of base plate from lag Mount with 6" Base Plate screws (see AppendixA & B of referenced report for _ test setup) This report shows results for our Quick Hook USA - Curved Tile Mount ' Notes: 1)Thread must be embedded in a rafter or other structural roof member. 2) See IBC for required edge distances. IMPORTANT: To maintain waterproofing of substrate it is important to make sure the aluminum sub -flashing is properly placed over the base plate and under the course of paper above. If the paper above does not reach,, due to layout, place an additional piece of roofing paper over the sub -flashing and under the next course of paper above. (See instructions on reverse) quick Mount PV'& BI 7.2.3=16 ® Feb -2013, Rev 6 1 of 3 Quick Hook USAm Curved Tile Mounting Instructions - Rafter Installation Installation Tools Required: stud finder, tape measure, utlity knife, 3/32" hex key, drill with 7/32" bit, impact dril with 1/2" socket, caulking gur, one tube of appropriate sealant compatible with roofing material, roofing bar, hand broom, stapler, 18" wide piece of underlayment or materials for 3 -course method during deck flashing installation. Remove the tile at selected location of the mount. Rest the base plate (item 1) over center of rafter Connect hook (item 3) to base plate and drive lag Locate and mark the center of the rafter. and mark center of holes. Drill two 7/32" pilot screws (item 2) into rafter through the two holes to holes and fill with sealant compatible with roofing a solid, snug fit. DO NOT over tighten lag screws, this material. may compromise their holding strength. Slide hook into desired position within valley of the tile. The hook must not overhang the side edges of the base plate. Tighten set screw (item 4) with hex key. Carefully clean the underlayment then apply bead of sealant compatible with roofing material in the shape of an upside down U on the backside of the sub -flash- ing (item 5) and install flashing over mount. Fasten sub -flashing to deck with one roofing nail in each top corner. Do not nail bottom corners. Proceed with weatherproofing using three -course method or lapped paper method' When using paper method, cut a piece of underlayment 18" wide to slide under the course above and over the sub -flashing. If course above is too high, you must use additional un- derlayment to ensure proper overlapping. Replace the tile above the hook. If necessary, notch the bottom of the tile to make space for the raised hook. Bolt the side -mounted rail of your choice to the . ` For more details on underlayment waterproofing hook, using the rail manufacturer's hardware. please visit our website: htti):/Iwwwciuickmounti3v.com/tile-waterr)roofinci /6 nick Mount 1 V. 925-478-8269 • www.quickmountpv.com • info@quickmountpv.com BI 7.2.3-16 2700 Mitchell Dr., Bldg. 2 e Walnut Creek, CA 94598 Feb -2013, Rev 6 2of3 BI 7.2.3-15 3.75 Quick Hook USAT"" Curved Tile Mount QMCTH Additional Dimensions =TER THIS EDGE TOWARDS ROOF RIDGE 7 IDJUSTABLE LOCATION 158.00° 9.00 4.92 3.75 23 . 1.4.00 1.85 SUBFLASHING (ITEM 5) THIS EDGE TOWARDS ROOF RIDGE .75 6.00 1.50 .5 1.50 .99 4.50 2.00 -Q- -Q- -Q- -+- ,.Quick Mount PV` TITLE: QMCTH: QUICK HOOK USA - lox 0.33 CLEARANCE CURVED TILE MOUNT BASE PLATE (ITEM 1) FOR 5/16' HARDWARE. UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAD REV DIMENSIONS ARE IN INCHES TOLERANCES: FRACTIONAL! 1/8 A DATE: 2/5/2013 3 - PROPRIETARY AND CONFIDENTIAL TWOPLACEDECIMAL 2.18 THEINFORMAA WHOLEWDHIION ONIAINED IN THIS DPAWM IS THE OUI THE WRITTEN PERMISSIONOFOUICK MOLE PROPERTY OF OUNT TV5 ROHIBITEDKMWMPV. ANY REPRODUCTION DI PART OR AS DO NOT SCALE DRAWING THREE PLACE DECIMAL 2.125 SCALE: 1:8 1 WEIGHT: 1.85 SHEET 2OF2 J H J L 3of3 I Feb -2013, Rev 6 0 Wiley Electronics LLC Washer, Electrical Equipment Bond WEEB Patent Pending INSTALLATION INSTRUCTIONS For Unirac Solar Mount only Please read carefully before installing. 7 -pow �-- WEEB-UMC WEEBL-6.7 WEEB Bonding Jumper -6.7 C ( US Products are tested to UL 467 3098177 UL standard for safety grounding and bonding equipment Document Number 104-0404-000010-011 Wiley Electronics LLC. 2006-2009© — All Rights Reserved M WEEB COMPATIBILITY The WEEB family of products can be used.. to bond anodized aluminum, galvanized steel, steel and other electrically conductive metal structures. Standard Top Down Clamps The WEEBs used for bonding the PV modules to the mounting rails are compatible with various cross-sections of module frames. The following are examples of module frames that are.compatible..Notice _that the WEEB teeth are positioned completely under the edge of the module frame. The WEEB-UMC is only compatible with module frames that have a reinforcing box structure, as illustrated below.' The following is an example of a module frame that is incompatible with the- WEEB. The WEEB teeth are positioned only partially under the edge of the module due to the lip�on the top edge of the module frame. I!rFF ln4�nn Not Compatil Wiley Electronics LLC.:�2006-2009© —All Rights Reserved Top Down Clamps for Lipped Modules The following are a few variations of lipped solar modules mounted with inverted U-shaped clamps. The low -lipped module requires use of the WEEB-DMC instead of the WEEB-UMC. Notice that the force which the inverted U-shaped clamp exerts is in line with the WEEB teeth. IL OK FRI FQ WEEB-DMC Low -Lipped Module WEEB-UMC is not compatible with high lipped modules. The WEEB teeth are not in line with the force of the inverted U-shaped clamps, with the result that the WEEB teeth do not embed properly. High -Lipped Module .j Wiley Electronics LLC. 2006-2009© —All Rights Reserved Si SYSTEM OVERVIEW Use WEEB-UMC to bond solar modules to module mounting rail ' connect mechanically spliced rails equipment ground conductor Important notes: 1. Use general purpose anti -seize compound on fastener threads when installing WEEBs. 2. WEEBs are intended for SINGLE USE ONLY. Functionality will not be guaranteed if reused. ,,Wiley Electronics LLC. 2006-2009© — All Rights Reserved O H WEEB-UMC ASSEMBLY Mid-Cla Pre -assemble WEEB-UMC to mid - clamp assembly as shown. Pre - assembling WEEB-UMC to mid - clamp assembly will contain the small individual parts, reducing the possibility of losing parts during installation. MI., A1..L 1 -4JVIL Wiley Electronics LLC. 2006-2009© — All Rights Reserved Spring retention tabs hold WEEB-UMC and rrirl i+l�rvr.,.e.�w,hli Drop in T -bolt and snap WEEB-UMC on to mounting rail Slightly lift solar module and slide WEEB-UMC and mid - clamp assembly into position. WEEB teeth will automatically be aligned under the edge of the module when mid clamp assembly is correctly installed. Important note: To correctly install mid -clamp assembly, ensure that the T- bolt is perpendicular to the mounting rail and both sides of the solar.. modules are,completely ompletely positioned against the mid clamp. Refer to WEEB compatibility page for illustrations. Wiley Electronics LLC. 2006-2009© — All Rights Reserved ® Important note: WEEBs are for SINGLE USE ONLY! Do not torque fasteners. down if position of solar modules is not finalized. Only slighty tighten fasteners to keep modules in place. ►hen position of solar odules are finalized, rque fasteners to 10 -Ib / 13.5 N -m using neral purpose anti- :ize compound on reads M Wiley Electronics LLC. 2006-2009© —All Rights Reserved WEEB-UMC LAYOUT EVEN NUMBER OF MODULES IN ROW' X DENOTES PLACES TO INSTALL WEEB-UMC CXR=4X1 WEEB-UMC NEEDED,- C X R= 4 X 1'= 4 ODD NUMBER OF MODULES IN ROW X DENOTES PLACES TO INSTALL WEEB=UMC CXR=5X1 WEEB=UMC NEEDED, _ [C+1} X R = [5+1] X 1 = 6 Note: When replacing a single:faulty module, also. remove the adjacent, module which contacts the same :WEEBs as the' faulty module. This will, ensure that there are never ungrounded modules in the array. .Wiley Electronics LLC. 2006-2009© —All Rights Reserved O I) WEEBLUG ASSEMBLY " WEEB teeth towards rail Slide bolt to desired position and slip bolt through WEEB-6.7 WEEB-6.7 Install.WEEBL-6.7 assembly and torque fasteners to 10 ft - lb / 13.5N -m using general - purpose anti -seize compound on threads Important note: WEEB-6.7.1hat sits under the WEEBLug is for single use only. Ensure position is correct before tightening down.' Wiley Electronics LLC. 2006-2009© —All Rights Reserved Wiley Electronics LLC. 2006-2009©— All Rights Reserved UMC SPLICE KIT ASSEMBLY (9 The flexible WEEB Bonding Jumper can be mounted in different ways shown below. WEEB {^StenerS to ,.5N -m eral inti seize J on threads rs to I ize treads Route WEEB Bonding Jumper as shown above if edge of solar module lands between two spliced," rails. Wiley Electronics LLC. 2006-2009© — All Rights Reserved ED IVIODL Pre -assemble WEEB-DMC to mi"i'] clamp assembly as shown. Pre --I, assembling WEEB-DMC to • clamp assembly will contain�! installation.small individual parts, re&Ci�Fg possibility of losing parts FA o orque to 10 ft -Ib / 13.5 N -m using eneral purpose anti -seize amp threads RTED WEEB-DMC Wiley LLC. 2006-2009© -All Rights Reserved D MID CLAMP i ke AdvaLQj ncing Renewable Technology ACCAcme Cable Clips ACME Cable Clips simplify wire management and create a cleaner aesthetic to solar PV arrays. The clips are made of corrosion resistant stainless steel and are designed to prevent damage to cable insu- lation. The easy to install and remove design only requires a flat head screwdriver and can be reused, unlike zip ties. The universal design fits most modules and can hold one or two wires. • Made with corrosion resistant 300 series stainless steel • Dual wire compartments • Special tab for easy installation and removal with flat -head screwdriver • Designed to prevent damage to cable insulation • Sized for USE -2 cable (5-5.4mm) or PV cable (6.8-7.2mm) ACC Holds: 1 to 2 USE -2 wires or 1 PV wire DC Power °Systems (800) 967-6917 www.dcpower-systems.com ACC- PV Holds: 1 to 2 PV wires Contact us at: 845.247.4708 www.we-Ilc.com