06-1011 (SFD)P.O. BOX 1504 4
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253 BUILDING & SAFETY DEPARTMENT
BUILDING PERMIT
Application Number: L_06-00001011 J Owner:
Property Address: 81804 RANCHO SANTANA DR DESERT ELITE, INC.
APN: 767-200-999-2 -312023- 78401 HIGHWAY 111, SUITE G
Application description: DWELLING - SINGLE FAMILY DETACHED LA QUINTA, CA 92253
Property Zoning: LOW DENSITY RESIDENTIAL (760)777-992O
Application valuation: 165860
Applicant: /hitect or Engineer:
mm�
---------------- --------------------------------
CENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury th t I licensed under provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Busines n Professionals Code, and my License is in full force and effect.
Licensle�Cla s: License No.: 753190
ate 7 li Co or:
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the
following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to
construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the
permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or
that he or she is exempt therefrom and the basis for the alleged exemption. Any violation ofSection7031.5 by
any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and 1-1
the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who builds or improves thereon,
and who does the work himself or herself through his or her own employees, provided that the
improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner -builder will have the burden of proving that he or she did not build or
improve for the purpose of sale.).
(_ 1 I, as owner of the property,.am exclusively contracting with licensed contractors to construct the project (Sec.
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of -
property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed
pursuant to the Contractors' State License Law.).
I—) I am exempt under Sec. , B.&P.C. for this reason
Date: Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the
work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name:
Lender's Address:
LQPERMIT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Contractor:
HERINGTON DEVELOPMENT, JAMES O
40960 CALIFORNIA OAKS RD, #283
MURRIETA, CA 92562
(951)677-8415
Lic. No.: 753190
Date: 3/13/06
tAUG012006
CITY OF LA QUINTA
FINANCE DEPT.
------------------
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
_ I. have and will maintain a certificate of consent to self -insure for workers' compensation, as provided
for by Section 3700 of the Labor Code, for the performance of the work for which this permit is
-Kissued.
ave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor
Code, for the performance of the work for which this permit is issued. My workers' compensation
insurance carrier and policy number are:
Carrier STATE FUND Policy Number 1542746-2005
I certify that, in the perfo ce of the work for which this permit is issued, I shall not employ any
person in any manner kh As to become subject to the workers' compensation laws of California;
and agree that, ijWOERS'
ecome subject to the workers' compensation provisions of Section
700 of the Labshall forthwith comply with those provisions.
/Date UC. pplicant:
WARNING: FAILURE TO SECURCOMPENSATION COVERAGE IS UNLAWFUL, AND SHALL
SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND
DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the
conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for
whose benefit work is performed under or pursuant to any permit issued as a result of this application,
the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City
of La Quinta, its officers, agents and employees for any act or omission related to the work being
performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced
within 180 days from date of issuance of ch permit, or cessation of work for 180 days will subject
permit to cancellation. .
I certify that I have read this application and state that th b e information is correct. I agree to comply with all
cityand my ordinances and state laws relating to buil nstruction, and hereby authorize representatives
of th' ou ty enter upon the above-mentioned propert • r nspection purposes.
atcryZl
ature (Applicant or Agent):
Application Number . . . . . 06-00001011
LQPERA1IT
Structure Information
Construction Type . .
. . TYPE V - NON RATED
Occupancy Type . . .
. . . DWELLG/LODGING/CONG <=10
Flood Zone . .
. . . NON -AO FLOOD ZONE
Other struct info
CODE EDITION
2001 CBC
# BEDROOMS
4.00
FIRE SPRINKLERS
NO
GARAGE SQ FTG
658.00
PATIO SQ FTG
319.00
NUMBER OF UNITS
1.00
-----------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
---
2600.00
--------------
Permit
BUILDING PERMIT
Additional desc .
Permit Fee . . . .
870.50 Plan Check Fee
565.83
Issue Date . . . .
Valuation . . .
. 165860
Expiration Date..
9/09/06
Qty. Unit Charge
Per
Extension
BASE FEE
639.50
66.00 3.5000
----------------------------------------------------------------------------
THOU BLDG 100,001-500,000
231.00
Permit . .
MECHANICAL
Additional desc .
Permit Fee . . .
90.00 Plan Check Fee
22.50
Issue Date . . . .
Valuation
0
Expiration Date
9%09/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00 .
2.00 9.0000
EA MECH FURNACE <=100K
18.00
2.00 9.0000
EA MECH B/C <=3HP/100K BTU
18.00
5.00 6.5000
EA MECH VENT FAN
32.50
1.00 6:5000
---------------------------------
EA MECH EXHAUST HOOD
---------------------------------------------
6.50
Permit . . . ELEC-NEW RESIDENTIAL
Additional desc .
Permit Fee . . . .
119.16 Plan Check Fee
29.79
Issue Date . . . .
Valuation . . .
. 0
Expiration Date
9/09/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
2600.00 .0350
ELEC NEW RES - 1 OR 2 FAMILY
91.00
LQPERA1IT
LQPERMIT
Application Number .
. . . . 06-00001011
Permit . . . . . . ELEC-NEW
RESIDENTIAL
Qty Unit Charge
Per
Extension
658.00 .0200
• ---------------------------------------------------
ELEC GARAGE OR NON-RESIDENTIAL.
-------------------------
13.16
Permit . . . PLUMBING
Additional desc .
Permit Fee . . . .
166.50 Plan Check Fee
41.63
Issue Date . . . .
Valuation . . . .
0
Expiration Date
9/09/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
16.00 6.0000
EA PLB FIXTURE
96.00
1.00 15.0000
EA PLB BUILDING SEWER
15.00
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
8.00 .7500
EA PLB GAS PIPE >=5
6.00
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS.METER
15.00
Permit . . . GRADING PERMIT•
Additional desc .
Permit Fee
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation . . . .
0
Expiration Date
9/09/06
Qty Unit Charge
Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
SFD - LOT 2, -PLAN 2AR,
2600 SF. PERMIT
DOES NOT INCLUDE POOL,
SPA, BLOCK WALLS,
OR DRIVEWAY.APPROACH.
2001 CBC, CMC,
CPC, 2004 CEC, 2005 ENERGY CODES
-
Other Fees . . . . .
-------- ----------------------------------------
. ... . ART IN PUBLIC PLACES -RES
.00
DIF COMMUNITY CENTERS -RES
74.00
DIF CIVIC CENTER - RES
480.00
ENERGY REVIEW FEE
56.58
DIF FIRE PROTECTION -RES
140.00
GRADING PLAN CHECK FEE
.00
DIF LIBRARIES --RES
355.00
DIF PARK MAINT FAC - RES
22.00
DIF PARKS/REC - RES
892.00
STRONG MOTION (SMI) - RES
16.58
LQPERMIT
LQPERMIT
Application Number
. . . . .
06-00001011
--------------------------------------------------------'--------------------
Other Fees . . . .
. . . . .
DIF STREET
MAINT FAC -RES
67.00
DIF TRANSPORTATION - RES
1666.00
Fee summary
-----------------
Charged
Paid
Credited
Due
Permit Fee Total
----------
1261.16
----------
.00
--------------------
.00
1261.16
Plan Check Total
659.75
.00
.00
659.75
Other Fee Total
3769.16
.00
.00
3769.16
Grand Total
5690.07
.00
.00
5690.07
10/06/2006 08:35 714-835-2819 ESIFME STRUCTURALENG PAGE 01/01
ESIIFME, Inc.
`
Date: 10-3-2006 _ By : P.G.P.
Structural Engineers
_
1800 E. 16th Street
Sheet 1
Santa Ana, Califomia 92701 .
Company: DES1=R I _ «I I c, Inc-
Project Name: "RANCHO SANTANA&
Address : 78-801 Highway 111., Suite G....._..
Ci orY_.._f Indio, CA.
La Quints CA 92253..--.
ES 1 IF M E Job No.:. 4428_ 98...
Contact : Greg Hegton cell:
rin
Project Eng.: R.R.W.
Phone : S760) 397-4122 FAX: (760) 397-4724
PH.: (714) 835-2800 / Fox 285-2819
I Phone conversatldn (X Field Meerg
j__ � MS'S I� Ciiemrs 1-7 in -Homo Meeting
v
Super. Dusty H Oh: (780).578.8256
Site: Monroe- VW 52nd Slieet.
Fox: (760) 398.7315
Str_u�tv�a_I �nralk of....Pas_e_4 on October 3rd.}._2006 .. Kevin Schmidt cell: (78023-9476
PLAN 4 Y A /Lot 1 : 89-790.Rancho Santana Drive
Porch tower. ADD plywood SWI 1' from header to top plate per plan.
Bath 4: ADD screws from DSC4 to girder truss per detail 21/SD2.
(Simp. ST6236 may be used in lieu of Simp. DSC4)
Garage: NAIL Simp.`A35's on rear wall per detail 18-2/SD1.
House: ADD 2x collar ties at hip apex.
PLAN 2 R 8 / Lot 2'81-804 Rancho Santana Drive
Porch tower: ADD plywood SW11 from header to top plate.
House: ADD 2x collar ties at hip apex.
I' Bdrm. 2: PRO\ADE 2x blocking at roof sheathing panel joints where noted on plans to
provide blocked 15132" roof sht'g.
Covered Porch Rear. ADD screws to DSC4 at each end of girder truss per detail 21/SD2.
Garage: NAIL Simp. A35's on rear wall per detail 18-2/SD1.
Patio: ADD S76236 from 4x8 beam to 4x12 beam at comer.
IPLAN 3 A /Lot 3 : 89-898 Rancho Santana Drive
Entry Porch: ADD SW10 shear lid at dropped ceiling.
Guest Suite: ADD Simp. ST6236 from top plate to truss (Simp. DSC4 not needed.)
Family: EPDXY FIX HD8A bolt at SW13 on right wall.
TIGHTEN center anchor bolt on Hardy panel 10x48 at rear wall.
Garage: NAIL Simp. A35's on rear wall per detail .1 WSW.
ADD plywood in each bay from the block on the top plate to the top block of the
lower roof that the roof shtg is nailed to on the Kitchen side. Above shear wall o
DISCLAIMER ESUFME, INC. DID NOT INSPECT THE SUBJECT UNITS, THESE WERE WALK•THRU FRAMING REVIEWS TO DETERMINE IF
CONSTRUCTION SUBSTANTIALLY COMPLIED WITH THE CONSTRUCTION DOCUMENTS AND STRUCTURAL DESIGN INTENT, OUR REVI
COVERED MAJOR FRAMING E!.—' �"' 4 4S REFLECTED IN OUR CALCULATIONS. THIS REVIEW WAS BASED ON VISUAL OSSERVATION
AND THERE IS No CLAIM, EITHER 5 FATED OR IMPLIED THAT ALL CONDITIONS WERE OBSERVED. WE DO NOT CERTIFY OR GUARANTE
CONSTRUCTION WORK IN ANY WAY. OUR VISIT DOES NOT RELIEVE THE DEVELOPERS, FRAMERS, CITY INSPECTORS AND DEPVTY
INSPECTORS pF REQUIRED) AS TO THEIR OBLIGATIONS TO FOLLOW ALL APPLICABLE CODES.
Toe; FRIYUJ" .w
IIINSTALLATION CERTIFICATE LIVIP-14= Z h �-} LA CF -6R
81: 8 w -Ram nc Santana Drive
Site Address
Permit #
An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this forni is
required; however, use of this form to provide the information is option[.) After completion of final inspection, a copy must be provided to the building department
(upon request) and the building owner at occupancy, per section 10-103(6).
HVAC SYSTEMS:
# of
Effeciency
Duct
Cooling Cooling
(pkg. heat CEC Certified Compressor Unit Mfr.
Heating Equipment
(SEER, etc)'
Location Duct
Load Capacity
pump, etc.) Name and Model Number
Systems
Equip. Type
# of
Efficiency
Duct
Duct or
Heating Heating
(pkg. heat CEC Certified Mfr, Make & Model
Identical
(AFUE,etc.)'
Location
Piping'
Load Capacity
pump, etc.) Number
Systems
[>_CF -I ]Zvalue]
' (attic, etc.)
R -value
(Btu/hr) (BTU/Hr)
FAU YORK LY8S080B I MH 11
2
80.0%
ATTIC
R-4.2
80,000
Cooling Equipment
Equip. Type
# of
Effeciency
Duct
Cooling Cooling
(pkg. heat CEC Certified Compressor Unit Mfr.
Identical
(SEER, etc)'
Location Duct
Load Capacity
pump, etc.) Name and Model Number
Systems
[>_CF -1R value]
(attic, etc.) R -value.
(Btu/hr) (BTU/Hr)
A/C COND. YORK HIRD042
2
14
ATTIC R-4.2 '
' 42,000
1 >_ reads greater than or equal to.
I, the undersigned, verify that the equipment listed above is: 1) is the actual equipment installed, (2) equivalent to or more efficient than that specified in the
certificate of compliance (Form CF -1 R) submitted for compliance with the Energy Efficiency Standards for residential buildings, and (3) equipment that meets or
exceeds the approp . to requirements for manufactured devices (from the Appliance Efficiency Regulations or Part 6), where applicable.
LDI Mechanical
ndy Yate 11/16/2006 HVAC Subcontractor (Co. Name)
OR General Contractor OR Owner
,G)
DUCT LEA]"" AND MWN DIAGNOSTICS
,v, MX'ZIN M11 Al' C U
,PressofflUttowTeivkaults (CFNf •@ 2'S PA) Test Leakage (CFM)-��
If WFIbvIrCitcutated as 400WhVton- x number oftons; or -as 2,1.7 x Heating Capacity
In Th, olyaands"'bf-9tu /hr, enter cdIcu.19tedwalue,here
Itfan fiow--W� measured, enter measured here
Leakage Fraction Test Leakagd(Measured,ot Calculated iFan -Flow)
Pas if "Jeak-agariadtion <046 ass Mill
utdr,alk-08,ft 0#-k:testing wax !tomA
* feted:
DuctPiro at roughiin measurid leakage (CFI )
WAIL:
ayes- 0,.,Nci b Wgitifmp& fdivor-!Hbuse:prt'sgun2afion* test
DVts
Pm Fail
a. Yes a No - T-,btmost,a1icZ#m§-i0n Valve is installed and Access is - provided for inspection
1. 0 Yes bNo
Yes jSrS_paSS 0
I= F911
the olans and duct.installation
f
•
2. C3 Yes G No VVistiostailled;or,FM� flow hasib.cen verified. If no TXXV, 0 a
verified,tim 66W matches design CF fioF-GL Pass FaU
Weasured-FarvRow
Yes for'both I and 2 is a Pass
0 I, file tatdetsigned, venfy that the above4i rftuki'm, the:Wor C orm associated with the testa) is in conformance
with tiie.#egtftmiiatb torctiripliaacti okdie a builtlshdil provide ttieiR.4 promo -s copy d,theid0AA"'A e-d�'bY,
the-60ftr
-the mita 6
eintj oyta orj��dh .Teqwftm or compliance
Gomm] Cohttacto*r (Co. Name)
con To..
applicable)
Bdildiftg4ftet,at Occupancy
A-2.5
DEC -22-2006 10:09 AM
CERTIi>P'YCATE OF
P.02
CF -4R
% Dfl-ate '
Buil r me
Telephone Plan Numbp►
2/v. t12 -a
Sample Group Number
tying Signature Sample House Number
Firm: IT, L. 4' is i o HERS provider. C
Street Address: 7�'��d �vo��a►•.! C/,&ir,- Citylstate2lp: /-4f 0114*%^e, , of
Copies to: Builder, HERS Pro4Ider
The house was: X Tested ❑ Approved as part of sample testing, but was not tested
As the HEM rater providing diagnostic testing and Heid verification, l ca"Itthat the houses Idenlffled on this form
com I with the diagnostic fegted compliance requirements as checked on this form,
Distributlon system Is fu11y ducted (i.e., does not use building cavities as plenums or platform returns In lieu
educts)
where cloth backed, rubber adhesive duct tape Is Installed, mastic and drowbands are used in combination
y«y cloth backed, rubbir adhesive duct tape to seal leaks at duct connections.
MINIMUM REQUIREMEP#3 FOR DUCT LEAKAGE REDUCTION COMPLIANCE CREDIT
Duct Diagnostic Leakage Te`eting Results (Maximum 6% Duct Leakage)
Msesured
Duct Pressurization Test Results (CFM ® 25 Pa) values c�
Test Leakage Flow In CFM J /
If fan flow Is calculated as 400cfm/ton x number of tons enter
calculated value here
assured enter measured value hero
Leakage Percentage (100 x Test Leakage/Fan Flow) = 7' L �Z v
Check Box for Pass or Fall (Pass=6% or less)E3N 't. ass Fall
eTHERMOSTATIC EXPANSION VALVE JTXVJ or Commission approved equivalent
Yea ❑ No Thermoitatic Expansion Valve (or Commission approved
equivalent) is Installed and Access Is provided for Inspection
Yes Is a pass
❑ MINIMUM REOUIREMENTO FOR DUCT DESIGN COMPLIANCE CREDIT
Z Yes O No ACCA`Manual D Design requirements have been met
(rater has verified that actual installation matches values in
CF -1 R and design on plan.
❑ Yes O No TXV is Installed or Fan flow has been verified. If no TXV,
vorified fan flow matches design from CF -1 R.
Measured Fan Flow =
Yea for both 1 and 2 le a Pass
M
C3
ass Fail
I
AX,
0 0 A
Pass Fall
m
2
INSTALLATION CERTIFICATE CF -6R
81-804 Rancho Santana Dr 2—
site address Permit #
An installation certificate is required to be posted at the building site prior to the issuance of the occupancy
permit; this form may be used to meet these requirements. All appliance categories listed below are the actual
equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better
than the appliance specified on the certificate of compliance (Form CF -IR). This certificate (or its equivalent)
shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation.
Refer to the reverse side of this certificate for an explanation of information required.
I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment
installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards.
In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified
on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards
for residential buildings.
HVAC SYSTEMS:
Heating Equipment
Heating Equipment CEC Certified Actual Distribution Heating Load Heating
Type (Packaged Manuf, Make & Effeciency Type and Before Over- Equipment
heat pump, etc.) Model Number AFUE, etc.) Location Sizing (Bluh) Capacity (Bluh
Cooling Equipment
Cooling Equipment Actual
Type (Packaged I CEC Certified Compressor Unit Efficiency Duct Duct
Heat Pump, etc.) Manuf, Make & Model Number (Seer) Location R -Valve
FAUCETS & SHOWER HEADS:
All faucets and showerheads installed are listed in the Commisions Directory of Certified Faucets and Showerheads,
pursuant to Title -24, Part 6, u chap. ter 2, Section 1 11.
On, (U I &AbZ�' (X 0 RCR COMPANIES
Ng�a—ture', Date Plumbing Subcontractor (Co. Name)
OR General Contractor OR Owner
RCR COMPANIES
Signature, Date
HVAC Subcontractor (Co. Name)
OR General Contractor OR Owner
WATER HEATING SYSTEMS:
Distrib. Water CEC Certified
Energy Tank Insul Internal Pilot Rated Solar/
System Heater Manuf, Make &
Factor/ Volume Wrap Insul. Energy Light Input Wood
Tvne Tvne/# Model #
Effic. (aallon.l R -value R -value Factnr (Rluh) Kw/Rt-11 Credits
FAUCETS & SHOWER HEADS:
All faucets and showerheads installed are listed in the Commisions Directory of Certified Faucets and Showerheads,
pursuant to Title -24, Part 6, u chap. ter 2, Section 1 11.
On, (U I &AbZ�' (X 0 RCR COMPANIES
Ng�a—ture', Date Plumbing Subcontractor (Co. Name)
OR General Contractor OR Owner
01-15-'07 11;26 FROM -
T -404 P03/11 U-666
' .umpire Insulation, Inc. Phone: (951) 7874844
3901 Carter Avenue, Suite 1 Fax: (951) 787-4849
Riverside, CA 91—IF
!:
X NSULATION CERTIFICATE 1
This is to certify that Insulation has been installed in conformance with the current
Energy Regulations & Building Codes of the City, County and State Governing Agencies
for the State of California.
PROJECT: RANCHO SANTANA
SITE ADDRESS: 81x790 RANCHO-SANTANA LA QUINTA
; 5
CA
Number Street
City
State r, .
LOT # .__?_.— PLAN #
2
CEILING AREA: BLOWN
Manufacturer: GREENFIBER Thickness/Type:
8.36"
R -Value: R-30
CEILING AREA: BA`TTS
Manufacturer: GUARDIAN Thickness/Type:
91./2"
R -Value: R-30
EXTERIOR WALbu.
i
Manufacturer: GUARDIAN Thickness/Type:
3 5/8"
R -Value: R-13
l
GENERAL CONTRACTOR:
LICENSE
#
BY: TITLE:
DATE:
.:? j ATION CONTRACTOR: EMPIRE 1NSUUATION
'LICENSE
*'860072
,BY: JOHN MIRANDA
DATE:
�4
h