BRES2017-0036A
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
Application Number: BRES2017-0036
Property Address: 79753 RANDOLPH CT
APN: 604520004
Application Description: LOPEZ / 270 SQ ADDITION
Property Zoning:
Application Valuation: $9,000.00
Applicant:
WORLDMARK CONSTRUCTION INC
81230 GARDENIA COURT
INDIO, CA 92201
c&',r4laQumrw
DESIGN & DEVELOPMENT DEPARTMENT
BUILDING PERMIT
NEW ROOM AND MASTER EXPANTION
IaY 2017
CWYOF(AQUIT
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that 1 am -licensed under provisions of Chapter 9
(commencing with Section 7000) of Division 3 of the Business and Professions Code, and
my License is in full force and effect.
License Class: B License No.: 998899
Date: ) contractor:
_ .
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State
License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any
structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractor's State
License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the j
alleged exemption. Any violation of Section 7031.5 by any applicant for a permit.
subjects the applicant to a civil penalty of not more than five hundred dollars ($500).:
(_) 1, as owner of the property, or my employees with wages as their sole.
compensation, will do the work, and the structure is not intended or offered for sale.
(Sec. 7044, Business and Professions Code: The Contractors' State License Law does not
apply to an owner of property who builds or improves, thereon, and who does the work
himself or herself through his or her own employees, provided that the improvements
are not intended or offered for sale. If, however, the building or improvement is sold
within one year of completion, the owner -builder will have the burden of proving that he
or she did not build or improve for the purpose of sale.).
(-1 I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State
License Law does not apply to an owner of property who builds or improves thereon,
and who contracts for the projects with a contractor(s) licensed pursuant to the
Contractors' State License Law.).
(� I am exempt under Sec. . B.&P.C. for this reason
Date
Owner:
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for
the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
i
Lender's Name:
Lender's Address:
VOICE (760) 777-7125
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Date: 5/15/2017
Owner:
GERARDO DANIEL LOPEZ
79-753 RANDOLPH CT
LA QUINTA, CA 92253
Contractor:
WORLDMARK CONSTRUCTION INC
81230 GARDENIA COURT
INDIO, CA 92201
(760)501-0492
Llc. No.: 998899.
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by
Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My workers' compensation insurance carrier and policy number are:
Carrier: STATE COMPENSATION INSURANCE FUND Policy Number: 9120127
-I certify that in the performance of the work for which this permit is issued, I
shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the
workers' compensation provisions of Section 3700 of the Labor Code, I•shall forthwith
comply with those provisions.
Date: _L -Applicant:
WARNING: FAILURE TO SECURE WOR COMPENSATION COVERAGE IS UNLAWFUL,
AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO
ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF
COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE,
INTEREST, AND ATTORNEY'S FEES.
APPLICANT ACKNOWLEDGEMENT
IMPORTANT: Application is hereby made to the Building Official for a permit subject to
the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose
request and for whose benefit work is performed under or pursuant to any permit issued,
as a result of this application , the owner, and the applicant, each agrees to, and shall
defend, in and hold harmless the City of La Quinta, its officers, agents, and
employees for any act or omission related to the work being performed under or
following issuance of this permit.
2. An
y permit issued as a result of this application becomes null and void if work is not
commenced within 180 days from date of issuance of such permit, or cessation of work
for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above information is correct.
I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this city to ente t e above-
mentioned property for inspection purposes.
Date:- L5 rSignature (Applicant or Agent)
Date: 5/15/2017
Application Number: BRES2017-0036 Owner:
Property Address: 79753 RANDOLPH CT GERARDO DANIEL LOPEZ
APN: 604520004 79-.753 RANDOLPH CT
Application Description: LOPEZ / 270 SQ ADDITION: NEW ROOM AND MASTER'EXPANTION LA QUINTA, CA 92253
Property Zoning:
Application Valuation: $9,000.00
Applicant: Contractor:
WORLDMARK CONSTRUCTION INC WORLDMARK CONSTRUCTION INC
81230 GARDENIA COURT
81.230 GARDENIA COURT
INDIO, CA 92201 INDIO, CA 92201
(760)501-0492
Llc. No.: 998899
--------------------------------------------------------------------------------------------
Detail: 274 SQ.FT. ADDITION OF BEDROOM AND EXPANDED MASTER BEDROOM TO EXISTING DWELLING. THIS PERMIT DOES NOT INCLUDE ADDITIONAL
MECHANICAL OR PLUMBING WORK, POOL, SPA, BLOCK WALLS OR DRIVEWAY APPROACH. 2016 CALIFORNIA BUILDING CODES.
FINANCIAL INFORMATION
DESCRIPTION ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF
101-0000-42400
0
$65.36
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, EA ADDITIONAL 500 SF PC
101-0000-42600
0
$18.24
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF
101-0000-42400
0
$127.68
DESCRIPTION
ACCOUNT
QTY
AMOUNT
ADDITION, FIRST 100 SF PC
101-0000-42600
0
$179.36
Total Paid for ADDITION: $390.64
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES ADMINISTRATIVE STAFF
101-0000-42600
0.25
$10.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
2
$190.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
1
$95.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
HOURLY CHARGE - YES STRUCTURAL PLAN REVIEW ENGINEER
101-0000-42600
0.5
$47.50
Total Paid for BLDG CITY STAFF - PER HOUR: $362.50
DESCRIPTION
ACCOUNT
QTY
AMOUNT
BSAS SB1473 FEE
101-0000-20306
.0
$1.00
Total Paid for BUILDING STANDARDS ADMINISTRATION BSA: $1.00
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20
101-0000-42403
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES, FIRST 20 PC
101-0000-42600
0
$25.33
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL
101-0000-42403
0
$27.83
DESCRIPTION
ACCOUNT
QTY
AMOUNT
DEVICES/FIXTURES, ADDITIONAL PC
101-0000-42600
0
$6.93
Total Paid for ELECTRICAL: $85.42
DESCRIPTION
ACCOUNT
QTY
AMOUNT
SMI - RESIDENTIAL
101-0000-20308
0
$1.17
Total Paid for STRONG MOTION INSTRUMENTATION SMI: $1.17
DESCRIPTION
ACCOUNT
QTY
AMOUNT
TECHNOLOGY ENHANCEMENT FEE
502-0000-43611
0
$5.00
Total Paid for TECHNOLOGY ENHANCEMENT FEE: $5.00-
Bin #
Permit
Project Address:O
_79-793
_6v_yAjf,
RQ
City of La Quin to
Building a Safety Division
78-495 Calle Tampico
La Quinta, CA 92253 - (760) 777-701,2
Building Permit Application and Tracking'Sheet
tvin 1,0 9 - & Owner's Name:
A. P. Number:
qad_63 _
Address: —7
Legal Description:
City, ST, Zip:
Contractbr:*U.)0fJdJ C� -
C0n_S4(C)C�1b/)
Telephone:-
Address: 60 f 4P,1
1\4
Project Description:
C . i . ty, _ S T Zip: La m4,ok,
C�
6N�3
A
- I
Teleh
p onc:bf"6) 5'01-0q?d
I '
')
State Lic. #%
4d'
Arch.,-Engr., Designer:
6024goe
Address:
City, ST, Zip:
Telephone:
. .... ...
........
. . . . . . . ...... ..........
Construction Type: Occupancy:
State Lu. 4:
Project type (circle one): New Add'n Alter Repair Demo
Name of Contact Person: Lope
Sq. Ft.:
# Storie"s:
1#
Telephone 4 of Contact Person: b6o)
lani
—L1 673
—Units:
Estimated Value of Project: 9,000.
--- - ---
APPLICANT: DO NOT..WRITE BELOW THIS LINE
H
Submittal
Rcqld
Rec'd
TRACKING
PERMIT FEES
Plan Sets
Plan Check submitted
Item
Amount
Structural Cates.
Reviewed, ready for corrections
Plait Check Deposit
Truss Cafes.
Called Contact Person
Plan Check Balance,
Title 24 Calcs.
Plans picked up
Construction
Flood plain plan
Plans resubmitted
Mechanical
Grading plan
2" Review, ready for corrections/issue
Electrical
Subcontactor List
Called Contact Person
Plumbing
Grant Deed
Plans picked up
S.M.I.
H.O.A. Approval
Plans resubmitted
Grading
IN HOUSE:-
Jrd Review, ready for corrections/issue
Developer Impact Fee
Planning Approval
Called Contact Pei -son
A.I.P.P.
Pub. Wks. Appr
Date of permit issue
SC11061 Fees,
Total Permigag 0 9
017
CITy OF LA ()UINTA
r
Date: 3/24/2017
No.: 17-00528-1 .
Owner: Gerado Daniel Lopez
Address: 79753 Randolph Court
City: La Quinta
Type: Residential Addition < 500 sq ft
Lot # Street No.
79753
Comments:
Street Name Sq. Feet. APN
Randolph Court 274 604-520-004
Permit No.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports,covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code.Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 274 S.F. or $0.00 have been"paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Exempt - Lupe Reyes Check No.:
Bank Name/Recipient of Certificate Telephone: 760-601-4673
Funding: Exempt
By Kathleen Felci
Interim Superintendent f"
Fee Collected Exempted b Sharo McGilvre
/ P Y Y Certificate Fees Due: ' $0:00
Original Payment(sl Rec'd::,` $'0.00
New Payment�Rec'd: $0.00
Over/Under:,, "$0:,00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will. serve to notify yo hat the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid.to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT. VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
CERTIFICATE•OF.COMPLIANCE .
r;N�iEc sc
Desert Sands Unified School Districtso
47950 Dune Palms Road
e' e:
"' �I C
La Quinta, CA 92253
as
r iuo WEUS y`
a�
(760)771=8515
Email'
Jurisdiction:
La Quinta
Tract #:
Street Name Sq. Feet. APN
Randolph Court 274 604-520-004
Permit No.
At the present time, the Desert Sands Unified School District does not collect fees on garages/carports,covered patios/walkways, residential additions
under 500 square feet, detached accessory structures (spaces that do not contain facilities for living, sleeping, cooking eating, or sanitation) or replacement
mobile homes. It has been determined that the above-named owner is exempt from paying school fees at this time due to the following reason:
Residential Addition 500 Sq Feet or Less
Exempt
This certifies that school facility fess imposed pursuant to
Education Code.Section 17620 and Government Code 65995 Et Seq.
in the amount of $0.00 X 274 S.F. or $0.00 have been"paid for the property listed above and that building permits
and/or Certificates of Occupancy for this square footage in the proposed project may now be issued.
Fees Paid By: Exempt - Lupe Reyes Check No.:
Bank Name/Recipient of Certificate Telephone: 760-601-4673
Funding: Exempt
By Kathleen Felci
Interim Superintendent f"
Fee Collected Exempted b Sharo McGilvre
/ P Y Y Certificate Fees Due: ' $0:00
Original Payment(sl Rec'd::,` $'0.00
New Payment�Rec'd: $0.00
Over/Under:,, "$0:,00
NOTICE: Pursuant to Government Code Section 66020(d)(1), this will. serve to notify yo hat the 90 -day approval period in which you may protest the fees or
other payment identified above will begin to run from the date on which the building or installation permit for this project is issued, or from the date on
which those amounts are paid.to the District(s) or to another public entity authorized to collect them on the District('s) behalf, whichever is earlier.
Notice to Building Department: THIS DOCUMENT. VALID ONLY IF IMPRINTED WITH EMBOSSED SEAL.
Plan Subml
Job Site
Owner's N
Number, Street, or PO
Chr, State, Postal C
Owners Phone Nun
Owner's E -Mail Add
Project Manager$ Ni
Projeo Managers Pho un
Project Managers E -mall -Add
Builder / Contn
Number, Street or PO
City, State, Postel C
Project Square
Building Permit Number. 6
°p Project Description: ISmall Addition
Exempt D
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction, Debris Management Plan
ate 5/15/2017.
me 79753 Randolph Ct
V .
me Geraldo Daniel Lopez
lox •79753 Randolph Ct
ids La Quinta, CA. 92253
bar 823-229-9749
ass aeraldo.d.looez[dtamail.com
me Jose (Lupe) Reyes
bar 780-801-4873 }}V<
x•`X a
no lupefdlworidmartrccnsbuctlon.com t+,
nor Woridmark Construction
iox 81230 Gardenia Ct
ode Indio, CA. 92201
ge Approx. 200 square feet
City Approval -By Rensdo Gouldiodt-DECdBurRec W
Date of City Approval
Aerials To Be Discarded:
Product
. rr
Plan Subml
Job Site
Owner's N
Number, Street, or PO
Chr, State, Postal C
Owners Phone Nun
Owner's E -Mail Add
Project Manager$ Ni
Projeo Managers Pho un
Project Managers E -mall -Add
Builder / Contn
Number, Street or PO
City, State, Postel C
Project Square
Building Permit Number. 6
°p Project Description: ISmall Addition
Exempt D
(Materials may contain hazardous wastes and
are not subject to recycling provisions)
Construction, Debris Management Plan
ate 5/15/2017.
me 79753 Randolph Ct
V .
me Geraldo Daniel Lopez
lox •79753 Randolph Ct
ids La Quinta, CA. 92253
bar 823-229-9749
ass aeraldo.d.looez[dtamail.com
me Jose (Lupe) Reyes
bar 780-801-4873 }}V<
x•`X a
no lupefdlworidmartrccnsbuctlon.com t+,
nor Woridmark Construction
iox 81230 Gardenia Ct
ode Indio, CA. 92201
ge Approx. 200 square feet
City Approval -By Rensdo Gouldiodt-DECdBurRec W
Date of City Approval
Aerials To Be Discarded:
Product
Tons
Trash
0.75 Not recyclable
Product
. Tons
Asphalt
0.00 Recyclable
Masonry (broken)
0.00
BrIck/Block
0.00 Recyclable
Plaster
0.25
Cardboard
0.00 Recyclable
Scrap Metal
0.00
Commingled
0.00 Recyclable
Tile (floor)
0.00
Concrete
0.80 Recyclable
Tile (roof)
0.03
_ Drywall
0.11 Recyclable
. Wood '
0.22
Donated / Reuse"
0.00 Recyclable
Landscape Debris
0.00
*Describe Items
Totals:. Rec cle Trash Projected Diversion:
1.4 0.8 8b.28°/6
I understand it is the property owners responsibility to submit copies of weight tickets or receipts to the District
Environmental Coordinator as these hauls occur. I hereby certify that completlon, implementation and adherence of the
Debris Management Plan (DMP) for the above named protect shall guarantee that at least 66% of the jobsite waste is
diverted from landfilling. The remaining material will be recycled or reuaed. I will divert, for recycling or re -use, remaining
materiels generated from the first day of the project through the completion of the project In accordance with this plan. This
DMP Is issued In the name of the property owner(s) and shall remain their properly throughout the construction and/or
demolition project A contractor serving as agent of the owner may obtain a DMP for the owner. However, the DMP is still
Issued In the name of the property owner(s) and the owner retains legal responsibility for ensuring that the provisions of the
DMP are adhered to. The pro owners) and general contractor shall be kept Informed of the diversion progress through
bl-monthly reports. K mg, pli refuse material from this project site must be taken to an approved recycler or transfer
-ttw-z-- - . sLis
Owner/ DsveIepdF7 Protect Manager/ Superintendent Date
,
..i
BUILDING ENERGY ANALYSIS REPORT
PROJECT:
MR. GERARDO DANIEL LOPEZ
79753 RANDOLPH' CT.
La Quinta, Ca 92253
Project Designer:
CASHCLA DESIGN & ASSOCIATES
45175 PANORAMA DR. - SUITE E
'Palm Desert, Ca 92260
(760) 272-9117
Report Prepared by:
SLO
Santiago Lopez-Ocampo
P.O. Box 1018
La Quinta, Ca 92247
760.485.8927
CITY OF LA QUANTA
BUILDING ,& SAFETY DEPT.
APPROVED
FOR CONSTRUCTION Job Number:
,J
DATE�I y (� LQ030217
REI
Zzv
Date: MAh 0
Ci7Y Ty OE'eL® mF-141
3/3/2017 COMMUN
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2016 Building Energy Efficiency Standards.
This program developed by EnergySoft Software — www.energysoft.com.
TABLE OF CONTENTS
Cover Page 1
Table of Contents 2
f
Form CF -1 R -PRF -01-E Certificate of Compliance 3
Form RMS -1 Residential Measures Summary 11
Form MF -1 R Mandatory Measures Summary 12
HVAC System Heating and Cooling Loads Summary 16
EnergyPro 7.1 by EnergySoft Job Number: ID: LQ030217 User Number: 5732
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis Input File Name: 79753 Randolph Ct - 030217.ribd16x
CF1R-PRF-01
Page 1 of 8
GENERAL INFORMATION
01 Building Complies with Computer Performances
01
Project Name MR. GERARDO DANIEL LOPEZ
03 This building incorporates one or:more Sp cial`Featuresshown below”'
05
02
Calculation Description Title 24 Analysis
08
Energy Use (kTDV/ftZ-yr)
03
Project Location 79753 RANDOLPH CT.
Compliance Margin
Percent Improvement
04
City La Quinta
05
Standards Version Compliance 2017
06
Zip Code 92253
07
Compliance Manager Version BEMCmpMgr 2016.2.1 (695)
08
Climate Zone CZ15
09
Software Version EnergyPro 7.1
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 90 -
12
Project Scope Addition and/or Alteration
13
Number of Dwelling Units 1
14
Total Cond. Floor Area (ft2) 2292
15
Number of Zones 2
16
Slab Area (ft) 2292
17
Number of Stories 1
18
Addition Cond. Floor Area 274
19
Natural Gas Available Yes
20
Addition Slab Arej„ift2 274
21
Glazing Percentage (%) 12.8%
COMPLIANCE RESULTS
01 Building Complies with Computer Performances
;
02 This building incorporates features„that regwre field test - s
ngand/orlverificatlon by axertifledi.HERS ratertunderA supervision of a CECapproved HERS provider.
03 This building incorporates one or:more Sp cial`Featuresshown below”'
05
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Exposed slab floor in conditioned zone
Registration Number: 217-Po10069892A-000-000-0000000-0000 - Registration Date/Time: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ftZ-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
2.40
1.30
1.10
45.8%
Space Cooling
206.72
201.21
5.51
2.7%
IAQ Ventilation
0.00
0.00
0.00
0.0%
Water Heating
10.82
10.82
0.00
0.0%
Photovoltaic Offset
—
0.00
0.00
—
Compliance Energy Total
219.94
213.33
6.61
3.0%
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• Exposed slab floor in conditioned zone
Registration Number: 217-Po10069892A-000-000-0000000-0000 - Registration Date/Time: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
HERS FEATURE SUMMARY
Input File Name: 79753 Randolph Ct - 030217.ribdl6x
CFI R -PRF -01
Page 2 of 8
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.
Building -level Verifications:
• Insulation Inspection
Cooling System Verifications:
--None --
HVAC Distribution System Verifications:
-- None --
Domestic Hot Water System Verifications:
-- None --
BUILDING - FEATURES INFORMATION
01
02
03
04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
MR. GERARDO DANIEL LOPEZ
,±2292`;
1
4
2
0
1
ZONE INFORMATION
01,
`y02r T
..M�.. 0304
_05
06
07
Zone Name
a
Zorie Typ.'
HVAC System Named(ftz)
Zone Floor Area
_
Avg Ceiling
Height;;
Water Heating System 1
Water Heating System 2
Addition'Gonditioned
HVAC Systern1 j>
Pf2,74
9.5;
DHW Sys 1
Existing
Conditioned
HVAC Systeml
2018 _
9.5�
DHW Sys 1
Registration Number: P17-P010069892A-000-000-0000000-0000 Registration Date/Time: 2017-03-03 06:11:16 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
Input File Name: 79753 Randolph Ct - 030217.ribd16x
CFI R -PRF -01
Page 3 of 8
OPAQUE SURFACES
01
02
03
04
05
06
07
08
09
10
Name
Zone
Construction
Azimuth
Orientation
Gross Area (ft2)
Window & Door
Area (W)
Tilt
(deg)
Status
Verified
Existing
Condition
Re/W
Addition
R-15 Wall
270
Back
94.1
0
90
New
N/A
Le/S
Addition
R-15 Wall
180
Left
257
25
90
New
N/A
Fr/E
Addition
R-15 Wall
90
Front
94.1
0
90
New
N/A
Roof
Addition
R-38 Roof Attic
174
New
N/A
Roof 2
Addition
R-38 Roof Attic
100
New
N/A
Ri/N
Existing
Default Wall 1992 to Pres
0
Right
483
56
90
Existing
No
Re/W 2
Existing
Default Wall 1992 to Pres
270
Back
470.5
150
90
Existing
No
Le/S 2
Existi4'1
Default Wall 1992 to Pres
270
Back
395.83
4
90
Existing
No
Fr/E 2
Existing: '
Default Wall 1992 to Pres
270
Back
259.33
54
90
Existing
No
Fr/SE
"Existing' " """
Default Wal1;1992 to Pres
_.. .
270
Back
32.58
24.5
90
Existing
No
Roof 3
Existin
R-30 Roof Attic
r.Roof
1009
Existing
No
4Existing
- £
R*Ot Roof Attic
,,.
'`009
Existing
No
ATTIC f "d _ ,; ' 04; �Z ':
01f
0203
1 0405
07
OB
09
10
Name
Construction
Type
Roof Rise
Roof
Reflectance
Roof
Emittance
Radiant
Barrier
Cool
Roof
Status
Verified Existing
Condition
Attic Addition
Attic RoofAddition
Ventilated
4
0.1
0.85
Yes
No
New
No
Attic Existing
Attic RoofExisting
Ventilated
4
0.1
0.85
No
No
Existing
No
Registration Number: P17-P010069892A-000-000-0000000-0000 Registration Date/Time: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
Input File Name: 79753 Randolph Ct - 030217.ribd16x
C F 1 R -PRF -01
Page 4 of 8
FENESTRATION / GLAZING
01
02
03
04 05
06
07
08
09
10
11
Name
Surface (Orientation -Azimuth)
Width(ft)
Height (ft) Multiplier
Area (W)
U -factor
SHGC
Exterior Shading
Status
Verified
Existing
Condition
5050 XO
Le/S (Left -180)
-
-- 1
25.0
0.50
0.24
Insect Screen (default)
New
N/A
4040
Ri/N (Right -0)
-
-- 1
16.0
0.71
0.73
Insect Screen (default)
Existing
No
4050
Ri/N (Right -0)
-
-- 1
20.0
0.71
0.73
Insect Screen (default)
Existing
No
40502
Ri/N (Right -0)
-
-- 1
20.0
0.71
0.73
Insect Screen (default)
Existing
No
6068
Re/W 2 (Back -270)
-
-- 1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
40503
Re/W 2 (Back -270)
-
- 1
20.0
0.71
0.73
Insect Screen (default)
Existing
No
40504
Re/W.,2 (Back -270)
-
-- 1
20.0
0.71
0.73
Insect Screen (default)
Existing
No
4010
Re/W:2 .(Back -270)
-
-- 1
4.0
0.71
0.73
Insect Screen (default)
Existing
No
2030
Re/W 2,(Back-270)
-
-- 1
6.0
0.71
0.73
Insect Screen (default)
Existing
No
60682
""- Re/W2 (Back -270)
-
-- 1
40.0
0.71
0.73
Insect Screen (default)
Existing
No
40505
"Re/W 2 (Back-270):'_a_y,20;0
X'0.71
0.73
Insect Screen (default)
Existing
No
40102
i Le/S 2 (Back -270) f
z
- 1
'40
rQ 71
X07$
Insect Screen (default)
Existing
No
5050
,' Fr/E-2 (Back270)
a� J '��1
ff;
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
Input File Name: 79753 Randolph Ct - 030217.ribd16x
C F 1 R -PRF -01
Page 5 of 8
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
08
09
Name
Zone
Total Cavity
Winter Design
Edge Insul. R -value
Construction Name
Surface Type
Construction Type
Framing
R -value
U -value
Assembly Layers
0.1
None
0
No
I New
No
• Cavity/ Frame: no insul. / 2x4 Top Chrd
Existing
2018
0.1
None
0
No
• Roof Deck: Wood Siding/sheathing/decking
No
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
Attic RoofAddition
Attic Roofs
Wood Framed Ceiling
in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
• Inside Finish: Gypsum Board
• Cavity/Frame: R -15/2x4
R-15 Wall
Exterior Walls
Wood Framed Wall
2x4 @ 16 in. O.C.
R 15
0.095
Exterior Finish: 3 Coat Stucco
• Inside Finish: Gypsum Board
Ceilings (below
Cavity/Frame: R-9.1 /2x4
R-38 Roof Attic
attic);
Wood Framed Ceiling
2x4 @ 24 in. O.C.
R 38
0.025
Over Ceiling Joists: R-28.9 insul.
Cavity / Frame: no insul. / 2x4 Top Chrd
Roof Deck. Wood Siding/sheathing/decking
2x4 Top Chord of Roof Truss @ 24
Tile Gap: present
Attic RoofExisting•;Attic
Roofs,
Wood -Framed Ceiling .x
_ in. O.C.
none
0.400
Roofing: 10 PSF (RoofTile)
:•'
t
Inside Finish: Gypsum Board
Cavity/Frame: R -13/2x4
Default Wall 1992 to Pres
Exterior Walls
`Wood Framed WaIC
,�.,
2x4 @ 16 in :O}C
+ _ �.
R 13
�,.
0: 01
Exterior Finish: 3 Coat Stucco
i
�
Inside Finish: Gypsumsum Board
Ceiling
�1
249n C
R 30
U;032
Cavity/Frame: R-9.1 /2x4
Over Ceiling Joists: R-20.9 insul.
R-30 Roof Attic
attic)
Wood,,Framed Ceding
2x4 @ O
SLAB FLOORS
01
02
03
04
05
06
07
08
09
Name
Zone
Area (ft2)
Perimeter
(ft)
Edge Insul. R -value
Carpeted
Fraction
Heated
Status
Verified
Existing
Condition
Slab -on -Grade
Addition
274
0.1
None
0
No
I New
No
Slab -on -Grade 2
Existing
2018
0.1
None
0
No
I Existing
No
BUILDING ENVELOPE - HERS VERIFICATION
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required —
Registration Number: 217-Po10069892A-000-000-0000000-0000 Registration Datemme: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
Input File Name: 79753 Randolph Ct - 030217.ribd16x
CFI R -PRF -01
Page 6 of 8
WATER HEATING SYSTEMS
01
02
03
04
05
06
07
08
Name
System Type
Distribution Type
Water Heater
Number of
Heaters
Solar
Fraction
N
Status
Verified Existing
Condition
DHW Sys 1
DHW
Standard
DHW Heater 1
1
Annual
Existing
No
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
Name
Heater
Element Type
Tank Type
Number
of Units
Tank
Volume
(gal)
Energy
Factor or
Efficiency
Input
Rating/Pilot
Tank Insulation
R -value
(Int/Ext)
Standby Loss /
Recovery Eff
NEEA Heat Pump Type
Tank Location or
Ambient
Condition
DHW Heater 1
Gas
Small Storage
1
50
0.575 EF
40000 Btu/hr
n/a
n/a
n/a
n/a
SPACE CONDITIONING SYSTEMS L
01
02
E 03
/ � �: �
04 05
06
07
08
09
Efficiency
Zonally Controlled
�Meating'System .
Cooling System
Name
System Type
EER
SEER
Name
System Type
--`
Name'
Ducted
Name
Distribution •
DuctedSystem
Fan
System;
Floor Area
; Served
Status
Verified Existing
Condition
HVAC S stem1
y
Other Heating and
Cooling System
Heating
Component1
Yes
'cooling
icomponentr1
Yes Air D tri ution
- -_ System 1
HVAC Fan
1
2292
Existing
No
HVAC - HEATING SYSTEMS
01 02 03
Name Type Efficiency
Heating Component 1 CntrlFurnace - Fuel -fired central furnace 78 AFUE
HVAC - COOLING SYSTEMS
01
02
03 04
05
06
07
Efficiency
Zonally Controlled
Multi -speed
Compressor
Name
System Type
EER
SEER
HERS Verification
Cooling Component 1
SplitAirCond - Split air conditioning
system
9.6
9.7
No
No
N/A
Registration Number: 217-Po10069892A-000-000-0000000-0000 Registration Date/Time: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ
Calculation Description: Title 24 Analysis
Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Input File Name: 79753 Randolph Ct - 030217.ribdl6x
CF1 R -PRF -01
Page 7 of 8
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
08
09
10
Insulation
Supply Duct
Return Duct
Verified Existing
HERS
Name
Type
Duct Leakage
R -value
Location
Location
Bypass Duct
Status
Condition
Verification
Air Distribution
Ducts located in attic
Existing (not
System 1
(Ventilated and
specified)
6.0
Attic
Attic
None
Existing
No
N/A
Unventilated)
IAQ (Indoor Air Quality) FANS
01 02 03 04 05
Name IAQ CFM IAQ Fan Type IAQ Recovery Effectiveness(%) HERS Verification
SFam IAQVentRpt 0 Default 0 Not Required
HI C E R S P R D
Registration Number: P17-Po100698924-000-000-0000000-0000 Registration DateTme: 2017-03-03 08:11:18 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695 Report Generated at: 2017-03-03 07:05:12
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: MR. GERARDO DANIEL LOPEZ Calculation Date/Time: 07:04, Fri, Mar 03, 2017
Calculation Description: Title 24 Analysis
Input File Name: 79753 Randolph Ct - 030217.ribdl6x
CF1R-PRF-01
Page 8 of 8
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
Santiago Lopez-Ocampo
Company:
Signature Date:
Santiago Lopez-Ocampo
2017-03-03 08:11:18
Address:
CEA/HERS Certification Identification (If applicable):
P.O. Box 1018
NA
City/State/Zip:
Phone:
La Quinta, CA 92247
760-485-8927
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. 1 am eligible under Division 3 of the Businessfand Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. a f
3. The building design features or system design features identifiedon=this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans'and specifications submitted toAhe enforcement agency for approval..with this -building permit application.
a.
i r f;
Responsible Designer Name:
£ A'' Aix
Responsible Designer Signature:
O
SantiagoCIt
Lo ez-Ocam o t
P PLPL
Company: ,�
r
Date Signed s
8.11:18
Santiago Lopez-Ocampo
2017-6j-03
Address:
License:
P.O. Box 1018
NA
City/State/Zip:
Phone:
La Quinta, CA 92247
760-485-8927
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010069892A-000-000-0000000-0000 Registration DateMme: 2017-03-03 08:11:18
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-02172017-695
HERS Provider: CaICERTS inc.
Report Generated at: 2017-03-03 07:05:12
RESIDENTIAL MEASURES SUMMARY
RMS -1
Project Name
MR. GERARDO DANIEL LOPEZ
Building Type 10 Single Family ❑ Addition Alone
❑ Multi Family m Existing+ Addition/Alteration
Date
3/3/2017
Project Address
79753 RANDOLPH CT. La Quinta
California Energy Climate Zone
CA Climate Zone 15
Total Cond. Floor Area
2,292
Addition
274
# of Units
1
INSULATION
Construction Type,
Area
Cavi (ft) Special Features
Status
Slab Unheated Slab -on -Grade - no insulation 2,292 Perim = 0'
Existing
Wall Wood Framed R 15 326
Altered
Wall Wood Framed R 15 94
New
Demising Wood Framed R 19 436
Existing
Roof Wood Framed Attic R38 274
New
Wall Wood Framed R 13 1,353
Existing
Door Opaque Door no insulation 20
Existing
Roof Wood Framed Attic R30 2,018
Existing
FENESTRATION I Total Area: 294 Glazing Percentage: 12-8%1New/Altered Average U -Factor:
Orientation Area(ft2) U -Fac SHGC Overhang Sidefins Exterior Shades
0.50
Status
Left (S) 25.0 0.500
0.24 none none Bug Screen
New
Right (N) 56.0 0.710
0.73 none none Bug Screen
Existing
Rear (Vlq 212.5 0.710
a 73 none none Bug Screen
Existing
HVAC SYSTEMS
Qtv. Heating Min. Eff
Cooling Min. Eff Thermostat
Status
1 Central Furnace 78% AFUE
Split Air Conditioner 9.7 SEER Setback
Existing
HVAC DISTRIBUTION
Location Heating
Duct
Cooling Duct Location R -Value
Status
HVAC System Ducted
Ducted Attic 6.0
Existing
WATER HEATING'
Qty- Type Gallons Min. Eff Distribution
Status
EnerqvPro 7.1 by EnerqySoft User Number 5732
ID: L 030217
Pae 11 of 16
h
2016CoResidential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more infoimation. *Exceptions may apply. `
fOrininal nwn1fi1 • •
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 cfm/ft' or less when tested per
NFRC400 or ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.'
§ 110.6(a)5:
Labeling. Fenestration products must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use LI -factors and solar heat gain coefficient (SHGC) values from TABLES
110.6-A and 110.6-B for compliance and must be caulked and/or weatherstripped.'
§ 110.7:.
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
asketed, or weather stripped.
§ 110.8(a):
Insulation Certification by Manufacturers. Insulation specified or installed must meet Standards for Insulating Material.
§ 110.8(g):,
Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) when the installation of a cool roof is specified on the CF1 R.
§ 110.80):
, Radiant Barrier. A radiant barrier must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood -frame ceiling; or the weighted average U -factor mustnot exceed 0.043.
Minimum R-19 or weighted average LI-factorof 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
§ 150.0(a):
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placin6 insulation either above or below the roof deck or on top of a drywall ceiling.'
§ 150.0(b):
Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R -value.
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U -factor of 0.102 or less (R-19 in 2x6 or LI -factor of 0.074 or
§ 150.0(c):.
less). Opaque non -framed assemblies must have an overall assembly LI -factor not exceeding 0.102, equivalent to an installed value of R-13 in a
wood framed assembly.*
§ 150.0(d):
Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum LI -factor.'§
150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings,' no greater than 0.3%; have a water vapor permeance no greater than 2.0 perm/inch; be protected from physical damage and UV light '
deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 11 0.8 .
§ 150.0(8)1:
Vapor Retarder. In Climate Zones 1-16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor retarder. This
re uirement also applies to controlled ventilation crawls ace for buildings complying with the exception to § 150.0(d).
§ 150.0(8)2:
Vapor Retarder. In Climate Zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation.
150.0
§ (q)'
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum LI -factor of 0.58; or the weighted average 1.1 -factor of all fenestration must not exceed 0.58.'
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 150.0(e)1A:
Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)1 B:
Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight -fitting damper or combustion -air control device.'
§ 150.0(e)1C: '
Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control.'
§ 150.0(e)2:
Pilot Light. Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of
the building, are prohibited.
Space Conditioning, Water Heating, and Plumbing System Measures:' -
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the Energy Commission.'
§ 110.2(a):
HVAC Efficiency. Equipment must meet the applicable efficiency requirements in TABLE 110.2-A through TABLE 110.2-K.'
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
§11 . 0.2(b):
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c):
Thermostats. All unitary heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
-
setback thermostat.'
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
§ 110.3(c)5:
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of §
110.3(c)5.'
§ 110.3(c)7:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBTU/hr (2 kW) must have isolation valves with hose bibbs
or other fittings on both cold water and hot water lines of water heating systems to allow for water tank flushing when the valves are closed.
§11 1 0.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces; household cooking appliances (appli-
ances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt); and pool and spa heaters.*
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with ASHRAE Handbook, Equipment
§ 150.0(h)l:
Volume, Applications Volume, and Fundamentals Volume; SMACNA Residential Comfort System Installation Standards Manual; or ACCA
Manual J using design conditions specified in § 150.0(h)2. '
2016 Low -Rise Residential Mandatory Measures Summary
§ 150.0(h)3A:
Clearances. Installed air conditioner and heat pump outdoor condensing units must have a clearance of at least 5 feet from the outlet of any
dryer vent.
§ 150.0(h)3B:
Liquid Line Drier. Installed air conditioner and heat pump systems must be equipped with liquid line filter driers if required, as specified by
manufacturer's instructions.
§ 150.00)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water -heating systems, must have
R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank.
Water piping and cooling system line insulation. For domestic hot water system piping, whether buried or unburied, all of the following must
be insulated according to the requirements of TABLE 120.3-A: the first 5 feet of hot and cold water pipes from the storage tank; all piping with a
§ 150.00)2A:
nominal diameter of 3/4 inch or larger; all piping associated with a domestic hot water recirculation system regardless of the pipe diameter;
piping from the heating source to storage tank or between tanks; piping buried below grade; and all hot water pipes from the heating source to
kitchen fixtures.'
§ 150.00)26:
Water piping and cooling system line insulation. All domestic hot water pipes that are buried below grade must be installed in a water proof
and non -crushable casing or sleeve.'
§ 150.00)2C:
Water piping and cooling system line insulation. Pipe for cooling system lines must be insulated as specified in § 150.00)2A. Distribution
piping for steam and h dronic heating systems or hot waters stems must meet the requirements in TABLE 120.3-A.'
§ 150.00)3:
Insulation Protection. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind.
Insulation Protection. Insulation exposed to weather must be installed with a cover suitable for outdoor service. For example, protected by
§ 150.00)3A:
aluminum, sheet metal, painted canvas, or plastic cover. The cover must be water retardant and provide shielding from solar radiation that can
cause degradation of the material.
§ 150.00)36:
Insulation Protection. Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must have a
Class I or Class II vapor retarder.
Gas or Propane Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of the following: a
§ 150.0(n)1:
120V electrical receptacle within 3 feet of the water heater; a Category III or IV vent, or a Type B vent with straight pipe between the outside
termination and the space where the water heater is installed; a condensate drain that is no more than 2 inches higher than the base of the
water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 200,000 Btu/hr.
§ 150.0(n)2:
Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water -heating Systems. Solar water -heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation SRCC or by a listing agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space -conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
CMC Compliance. All air -distribution system ducts and plenums must be installed, sealed, and insulated to meet the requirements of CMC
§§ 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions
of supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 (or higher if required by CMC § 605.0) or
a minimum installed level of R-4.2 when entirely in conditioned space as confirmed through field verification and diagnostic testing
§ 150.0(m)1:
(RA3.1.4.3.8). Connections of metal ducts and inner core of flexible ducts must be mechanically fastened. Openings must be sealed with
mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181 B or aerosol sealant that
meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or
tape must be used. Building cavities, support platforms for air handlers, and plenums designed or constructed with materials other than sealed
sheet metal, duct board or flexible duct must not be used for conveying conditioned air. Building cavities and support platforms may contain
ducts. Ducts installed in cavities and support platforms must not be compressed to cause reductions in the cross-sectional area of the ducts:
Factory -Fabricated Duct Systems. Factory -fabricated duct systems must comply with applicable requirements for duct construction,
§ 150.0(m)2:
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tae is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field -Fabricated Duct Systems. Field -fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7:
Backdraft Dampers. All fan systems that exchange air between the conditioned space and the outside of the building must have backdraft or
automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
Protection of Insulation. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
§ 150.0(m)9:
wind. Insulation exposed to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or
plastic cover. Cellular foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from
solar radiation.
§ 150.0(m)10:
Porous Inner Core Flex Duct. Porous inner core flex duct must have a non -porous layer between the inner core and outer vapor barrier.
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
§ 150.0(m)11:
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0 m 11 and Reference Residential Appendix RA3.
Air Filtration. Mechanical systems that supply air to an occupiable space through ductwork exceeding 10 feet in length and through a thermal
§ 150.0(m)12:
conditioning component, except evaporative coolers, must be provided with air filter devices that meet the design, installation, efficiency,
pressure drop, and labeling requirements of § 150.0(m)12.
2016 Low -Rise Residential Mandatory Measures Summary
Duct System Sizing and Air Filter Grille Sizing. Space conditioning systems that use forced air ducts to supply cooling to an occupiable
space must have a hole for the placement of a static pressure probe (HSPP), or a permanently installed static pressure probe (PSPP) in the
§ 150.0(m)13:
supply plenum. The space conditioning system must also demonstrate airflow >_ 350 CFM per ton of nominal cooling capacity through the return
grilles, and an air -handling unit fan efficacy <_ 0.58 WICFM as confirmed by field verification and diagnostic testing, in accordance with
Reference Residential Appendix RA3.3. This applies to both single zone central forced air systems and every zone for zonally controlled central
forced airs stems.'
Ventilation for Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2. Neither window operation nor
§150.0(0):
continuous operation of central forced air system air handlers used in central fan integrated ventilation systems are permissible methods of
providing whole -building ventilation.
§ 150.0(o)1A:
Field Verification and Diagnostic Testing. Whole -building ventilation airflow must be confirmed through field verification and diagnostic
testing, in accordance with Reference Residential Appendix RA3.7.
Pool and Spa Systems and Equipment Measures:
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
§ 110.4(a):
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.'
§ 110.4(b)1:
Piping. Any pool or spa heating equipment must be installed with at least 36 inches of pipe between the filter and the heater, or dedicated
suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2:
Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional inlets and time switches for pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:
Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
150.0
§ (p)'
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.'
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.'
§ 110.9(e):
JA8 High Efficacy Light Sources. To qualify as a JA8 high efficacy light source for compliance with § 150.0(k), a residential light source must
be certified to the Energy Commission according to Reference Joint Appendix JA8.
§ 150.0(k)1A:
Luminaire Efficacy. All installed luminaires must be high efficacy in accordance with TABLE 150.0-A.
Blank Electrical Boxes. The number of electrical boxes that are more than 5 feet above the finished floor and do not contain a luminaire or
§ 150.0(k)1 B:
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
§ 150.0(k)1C:
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C. A JA8-2016-E light source rated for
elevated temperature must be installed by final inspection in all recessed downli ht luminaires in ceilings.
§ 150.0(k)1 D:
Electronic Ballasts. Ballasts for fluorescent lamps rated 13 wafts or greater must be electronic and must have an output frequency no less than
20 kHz.
Night Lights. Permanently installed night lights and night lights integral to installed luminaires or exhaust fans must be rated to consume no
§ 150.0(k)1 E:
more than 5 wafts of power per luminaire or exhaust fan as determined in accordance with § 130.0(c). Night lights do not need to be controlled
by vacancy sensors.
§ 150.0(k)1 F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
Screw based luminaires. Screw based luminaires must not be recessed downlight luminaires in ceilings and must contain lamps that comply
§ 150.0(k)1G:
with Reference Joint Appendix JA8. Installed lamps must be marked with "JA8-2016" or "JA8-2016-E" as specified in Reference Joint Appendix
JAB.'
§ 150.0(k)1 H:
Enclosed Luminaires. Light sources installed in enclosed luminaires must be JA8 compliant and must be marked with "JA8-2016-E."
§ 150.0(k)2A:
Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B:
Interior Switches and Controls. Exhaust fans must be switched separately from lighting systems.'
§ 150.0(k)2C:
Interior Switches and Controls. Luminaires must be switched with readily accessible controls that permit the luminaires to be manually
switched ON and OFF.
§ 150.0(k)2D:
Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer's instructions.
§ 150.0(k)2E:
Interior Switches and Controls. No control must bypass a dimmer or vacancy sensor function if the control is installed to comply with
150.0(k).
§ 150.0(k)2F:
Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with dimmer requirements if it:
§ 150.0(k)2G:
functions as a dimmer according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the EMCS requirements of §
130.5ft and meets all other requirements in § 150.0(k)2.
Interior Switches and Controls. An EMCS may be used to comply with vacancy sensor requirements in § 150.0(k) if it meets all of the
§ 150.0(k)2H:
following: it functions as a vacancy sensor according to § 110.9; the Installation Certificate requirements of § 130.4; the EMCS requirements of §
130.5ft and all other requirements in § 150.0(k)2.
§ 150.0(k)21:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
2016 Low -Rise Residential Wandatory Measures Summary
§ 150.0(k)2J:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by a vacancy sensor.
§ 150.0(k)2K:
Interior Switches and Controls. Dimmers or vacancy sensors must control all luminaires required to have light sources compliant with
Reference Joint Appendix JAB, except luminaires in closets less than 70 square feet and luminaires in hallways.'
§ 150.0(k)2L:
Interior Switches and Controls. Undercabinet lighting must be switched separately from other lighting systems.
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
§ 150.0(k)3A:
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either item
§ 150.0(k)3Aii (photocell and motion sensor) or item § 150.0(k)3Aiii (photo control and automatic time switch control, astronomical time clock, or
EMCS.
Residential Outdoor Lighting. For low-rise multifamily residential buildings, outdoor lighting for private patios, entrances, balconies,
§ 150.0(k)3B:
and porches; and outdoor lighting for residential parking lots and residential carports with less than eight vehicles per site must comply with
either § 150.0(k)3A or with the applicable requirements in §§ 110.9, 130.0, 130.2,130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting not regulated by
150.0(k)3B or § 150.0(k)3D must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3D:
Residential Outdoor Lighting. Outdoor lighting for residential parking lots and residential carports with a total of eight or more
vehicles per site must comply with the applicable requirements in §§ 110.9, 130.0, 130.2, 130.4, 140.7, and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
ower as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in §§ 110.9, 130.0, 130.1,130.4,140.6, and 141.0.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
§ 150.0(k)6A:
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be high efficacy luminaires and controlled by an occupant sensor.
Interior Common Areas of Low-rise Multi -Family Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting in that building must:
§ 150.0(k)6B:
i. Comply with the applicable requirements in §§ 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
Single Family Residences. Single family residences located in subdivisions with ten or more single family residences and where the
§ 110.10(a)1:
application for a tentative subdivision map for the residences has been deemed complete by the enforcement agency must comply with the
requirements of § 110.1 0 b through § 110.10 e .
§ 110.10(a)2:
Low-rise Multi -family Buildings. Low-rise multi -family buildings must comply with the requirements of § 110.10(b) through § 110.10(d).
Minimum Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access, pathway, smoke
ventilation, and spacing requirements as specified in Title 24, Part 9 or other Parts of Title 24 or in any requirements adopted by a local
jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80 square feet
each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with roof areas
§ 110.10(b)1:
greater than 10,000 square feet.
For single family residences the solar zone must be located on the roof or overhang of the building and have a total area no less than 250
square feet. For low-rise multi -family buildings the solar zone must be located on the roof or overhang of the building, or on the roof or overhang
of another structure located within 250 feet of the building, or on covered parking installed with the building project, and have a total area no less
than 15 percent of the total roof area of the building excluding any skylight area.'
§ 110.10(b)2:
Orientation. All sections of the solar zone located on steep -sloped roofs must be oriented between 110 degrees and 270 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at least twice the
§ 110.10(b)3B:
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical lane.'
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
Interconnection Pathways. The construction documents must indicate: a location for inverters and metering equipment and a pathway for
§ 110.10(c):
routing of conduit from the solar zone to the point of interconnection with the electrical service (for single family residences the point of
interconnection will be the main service panel); and a pathway for routing of plumbing from the solar zone to the water -heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
1 10.10 c must be provided to the occupant.
§ 110.10(e)1:
Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
§ 110.10(e)2:
breaker for a future solar electric installation. The reserved space must be: positioned at the opposite (load) end from the input feeder location or
main circuit location; and permanently marked as 'For Future Solar Electric".
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
Project Name
MR. GERARDO DANIEL LOPEZ
Date
3/3/2017
System Name
HVAC System
Floor Area
2,292
ENGINEERING CHECKS
SYSTEM LOAD
Number of Systems
1
Total Room Loads,
Return Vented Lighting
Return Air Ducts
Return Fan
Ventilation
Supply Fan
Supply Air Ducts
TOTAL SYSTEM LOAD
COIL
CFM
2,055
0
COOLING
PEAK
COIL HTG.
PEAK
Heating System
Sensible
Latent
CFM
Sensible
Output per System 80,000
39,372
792
616
23,510
Total Output (Btuh) 80,000
0
Output Btuh/s ft 34.9
2,687
1,356
Cooling System
0
0
Output per System 1
0
0
0
0
Total Output Btuh) 1
0
792
0
Total Output Tons 0.0
2,687
1,356
Total Output (Btuh/sgft) 0.0
Total Output s ft/Ton 27,504,000.0
1 44,746
26,222
Air System
CFM per System
0
HVAC EQUIPMENT SELECTION
Airflow cfm
0
1992 - 2005 Fau/AC
1 0
80,000
Airflow cfm/s ft
0.00
Airflow (cfm/Ton) 0.0
Outside Air (%)
0.0%
Total Adjusted System Output
(Adjusted for Peak Design conditions)
TIME OF SYSTEM PEAK
1 0
Aug 3 PM
80,000
Jan 1 AM
Outside Air cfm/sgft) 0.00
Note: values above given at ARI conditions
HEATING SYSTEM PSYCHROMETRICS
Airstream Temperatures at Time of Heating Peak
26 OF
Outside Air
0 cfm
67 OF
67 OF 105 OF
WOW
Heating Coil
,.....�
104 OF
ROOM
68 OF
COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
112/73°F
Outside Air
Ar
0 cfm
77 / 62 OF
77/62°F 55/54°F
LJ— ILA
Cooling Coil �■ 57 J 55 OF
46.6% ROOM
...
75/ 62 OF
EnergyPro 7.1 by EnergySoft
User Number. 5732
/D: LQ030217 Page 16 of 16