Loading...
13-0723 (SOL)w1` :, \, . P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00000723 Property Address: 51150 CALLE QUITO. APN: 770-144-001-123 -000000- Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 70000 Applicant: (,oK�/lgca�tJ1l1 Architect or Engineer: a:1 r 4 4,4 BUILDING & SAFETY DEPARTMENT BUILDING PERMIT LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: ,B -C10 License No.: X35263 Contractor: It OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031 .5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she'is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil -penalty of not more than five hundred dollars ($500).: (_ I I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ` (_ I I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: - Lender's Address LQPERMIT Owner: FRED DIVINE. 51150 CALLE QUITO LA QUINTA, CA 92253 (760)275-9819 Contractor: VERENGO INC 20285 S. WESTERN AVE, TORRANCE, CA 90501 (310)803-9053 Lic. No.: 935263 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 7/18/13 WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier ZURICH INS Policy Number WC58338700 _ I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall fort) com with tho ee provisions. Date: ? Z Applicant: �`- c WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby author' a representatives of this co my enter upon the above-mentioned property for inspection pur es. rt' ..+< Bate: Signature (Applicant or Agent): _ Application Number . . .. 13-00000723 Permit . .ELECTRICAL 2013 Additional desc . Permit Fee 71.49 Plan Check Fee .00 Issue Date Valuation . . . . 0 Expiration Date 1/14/14 Qty Univ Charge Per Extension 1.00 23.8300 LS ELEC DEVICES,< FIRST 20 23:83 1.00 23.8300 EA ELEC SERVICES 23.83 1.00 23.8300 -EA ELEC OTHER EQUIP' 23.83 -------------------------------- ------------------------------------------- Special Notes and Comments 17.2kW SOLAR ARRAY - (70) 245W YINGLI PANELS W/ (3) PVI -5000 POWER ONE INVERTERS AND 225AMP PANEL UPGRADE (1,246SF] 2010 CALIFORNIA ELECTRICAL CODE. July 18, 2013 3:00:18 PM AORTEGA ---------------------------------------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 3.00 PLAN CHECK, ELECTRICAL 59.58 PERMIT ISSUANCE M/P/E 90.57 Fee summary Charged Paid Credited --------------------------------------------------------- Due Permit Fee Total 71.49 .00 .00 71.49 Plan Check Total .00 .00 .00 .00 Other Fee Total 153.15 .00 .00 153.15 Grand Total 224.64 .00, .00 224.64 • Bin # City of La Quinta Building Br Safety Division P.O. Box 1504, 78-495 Calle Tampico JUN 0.6 201 La Quinta, CA 92253 - (760) 777-7012 of Qu ' Building Permit Application and Tracking S 41 INTTY nFVFIj F Permit # Project Address: (SyIJ t'e au Owner's Name:' �E21✓ i U A. P. Number: Address: Sj / 5 �( l e U-( Legal Description: City, ST, Zip:14a G 922 Contractor: Telephone: 2 Z — 1819<>{.f• Y s :>?:>oY> :•w?:::}:,.. Address:L 8 S. S f,Y� �U� ZOO Pro'1ec escri tion:v� �VAw 7 fi City, ST, Zip: li !A (/L C �✓�6 (J 2 Z !�T^tP 11 Telephone: D C�� <><>.>:•. 2//� {,•, :;>{.}{;: ifrv,%'1.•i;? .t:i;•>ffh?•J: / L- �V' `f..��� .�Q State Lic. # : 9_3572(P'3 City Lic. C ,3 Arch., Engr., Designer: Address: 10 Q_ n p cr - "(41&u �a+'s+*'e, sql; J T�Ld. . City., ST, Zipr64. Y ' t . l ,, crzii ?7 C VW00 % lw&'L aas Telephone: Q — �/ 28S �OK :{:'•.':':}cW zw€s':`: `>? ;•. �.•:.:.',.'" :`ConstructionType: S Occupancy: .s>:"��>�,�%r:^#<�z �,» <'>:;'.»`?': �>c <..>:{.,{::f Project type (circle one): New Add'n Alter Repair Demo State Lic. #: to Name of Contact Person: ia— V 12a IM 1(--e Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: I 3 l Estimated Value of Project: '�© 00c) APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check submitted (CAA Item Amount Structural Calcs.. Reviewed, ready for corrections is,Plan Check Deposit Truss Calcs., Called Contact Person Plan Check Balance Tide 24 Cales. Plans picked up Jdll Construction Flood plain plan Plans resubmitted Mechanical Grading plan 2•. Review, ready for correctio ssu Electrical Subcontactor List Called Contact Person X91 Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted Grading IN HOUSE:- '"' Review, ready for correctionsfissue Developer Impact Fee Planning Approval Called Contact Person I,p,p, Pub. Wks..Appr Date of permit issue School Fees Total Permit Fees 6 1 zb 114r; sow zfL 'Y Impilso � S.A4 woo^av FA IMENT , j'y4 k T i 5 a Yt ' •�2 F . �? )1 Part# FJ-300-1�8�� " ; ,9�{{..r r�`mm ~r �• For low profile mstalloiions using Oatey® flashings (forcomposttlon shingle(oof tops)`' s.' • .t ,��'^,�' f :-Fdr=zt„N:x�"^.i .bL. t" kr!° A4/2'; �F�J�450-18*js., ��' For mstallotlons using standard flasbrigs (for,eo.mposttionj& flat rooftops)`,`; �^6a Hi9`b � FJ: ;a �� f ,� t ,a"" fia• `moi tr : t'4.rpr'P rl '. ',.� �?j,,Port# FJ 60018r 'y�, �!'r:•- j t° Kira : LL For standard flashings rghw;•'�y�a��z,`Port#,F1750v18_`""� +a, fi�nz s�*sc � ..Mrks�c'4"��a�r���R For standard flashings (sized #or S curve the roofs and/or double flashed msiallations) S FastJack® FJ -450-18 For standard helghl flashings . , A". The Fast Jack@ design is covered under Pat. #6,360,491 ; s Using lea. 5/16" x 31/2" Lag Boll 4 /ice ?; v Cor�merciaB,Fastlack® alsoavatlabhe (rated�at4250�1lis Easy installation �eriefits of tale° F'asfJ k4i of flashings on 3/8" SS 3/8" x 3/d" • Removable post makes mstdllahon on ;existed Flat washer t i ^� t g • � SS Hex Eolt� roofs/ trofi�qu�k and easy (refeito the dlustiatlon existing roof -tops to the nglit) t - Sea rz:; :e fa. iiak:!iolir. t heal'; Patented design'Jocates theFlag bolt. directly The post can be oder` the -stanchion providing `superior fiengih jalae;£'�,y Standard & Oatey@ Flashings installed through slip over the base and under the the to of the costs ostteasy ttot nstalpv �s me arid,l; bar i p t { delicate shingle i flashing 'aEPrepsio machined from extruded alumin m P'ihere are no welds t'o corrode or breok ' ! 45 / - '1 " � � �Slgnifi�untly hgfiter than steel,for installer'-`''� ` / fconvemence and reduced shipping ost's y - z4' 5116" x 3-1/2 Integ?olid drill guide insures perfect pilot, kholes ss fag Bolt �'�>• ` vsevery. hme minimiiBs the poisblhrysaf sphthng Threaded Fast tBase design all virtually; y roof flashmg,to., {mstalfflot on the roof deck Email us for s more information prosolar@ prosolar cam rGora[ory 7erted ' st`3 ® y��;lrertual,Ihr!lautr��' r ` 808y1bs C Y ..+ 5tJa Site Acrlrl 'ullo'i !• f; ? r .y. r s s c' 4 Patent #6,360,491 Y _• Flashable Roof Stanchion FastJack® FJ -300-18 " The patented design of the FastJack@ can be easily expressed as the most innovative, efficient For Oatey@ style Flashings and cost-effective tool of it's kind! : 4 ;A Between the precision M machined base and stanchion along with strict engineering and . yfi material standards, the FostJock® has been laboratory tested to provide 2,359 pounds of ` strength using only a single lag bolt (included)! Four Sizes Available! , j'y4 k T i 5 a Yt ' •�2 F . �? )1 Part# FJ-300-1�8�� " ; ,9�{{..r r�`mm ~r �• For low profile mstalloiions using Oatey® flashings (forcomposttlon shingle(oof tops)`' s.' • .t ,��'^,�' f :-Fdr=zt„N:x�"^.i .bL. t" kr!° A4/2'; �F�J�450-18*js., ��' For mstallotlons using standard flasbrigs (for,eo.mposttionj& flat rooftops)`,`; �^6a Hi9`b � FJ: ;a �� f ,� t ,a"" fia• `moi tr : t'4.rpr'P rl '. ',.� �?j,,Port# FJ 60018r 'y�, �!'r:•- j t° Kira : LL For standard flashings rghw;•'�y�a��z,`Port#,F1750v18_`""� +a, fi�nz s�*sc � ..Mrks�c'4"��a�r���R For standard flashings (sized #or S curve the roofs and/or double flashed msiallations) S FastJack® FJ -450-18 For standard helghl flashings . , A". The Fast Jack@ design is covered under Pat. #6,360,491 ; s Using lea. 5/16" x 31/2" Lag Boll 4 /ice ?; v Cor�merciaB,Fastlack® alsoavatlabhe (rated�at4250�1lis Easy installation �eriefits of tale° F'asfJ k4i of flashings on 3/8" SS 3/8" x 3/d" • Removable post makes mstdllahon on ;existed Flat washer t i ^� t g • � SS Hex Eolt� roofs/ trofi�qu�k and easy (refeito the dlustiatlon existing roof -tops to the nglit) t - Sea rz:; :e fa. iiak:!iolir. t heal'; Patented design'Jocates theFlag bolt. directly The post can be oder` the -stanchion providing `superior fiengih jalae;£'�,y Standard & Oatey@ Flashings installed through slip over the base and under the the to of the costs ostteasy ttot nstalpv �s me arid,l; bar i p t { delicate shingle i flashing 'aEPrepsio machined from extruded alumin m P'ihere are no welds t'o corrode or breok ' ! 45 / - '1 " � � �Slgnifi�untly hgfiter than steel,for installer'-`''� ` / fconvemence and reduced shipping ost's y - z4' 5116" x 3-1/2 Integ?olid drill guide insures perfect pilot, kholes ss fag Bolt �'�>• ` vsevery. hme minimiiBs the poisblhrysaf sphthng Threaded Fast tBase design all virtually; y roof flashmg,to., {mstalfflot on the roof deck Email us for s more information prosolar@ prosolar cam astJack Bulk packaging means easier stocking abilities, less packaging waste and quicker, more convenient Finstallafion. Everything in the photo below is shipped in a recloseable box for storage of extra parts. Nuow s4ia0.�vi The Fast Jack® is available in four convenient sizes. All sizes are packaged in quantities of 18 per box: � � ❑ a,o o°v Uilo"(LIP1(11 >rt Li'l(: r- jjjjjjjjj il I ti,ttlirLll I Li 43' Easy Installation: Step : Seal fishing around the post to aterproof o M. 18 1" Round Posts (3", 4-1/2", 6" or 7-1/2" tall) 18 Threaded bases 18 3/8" x 3/4" SS Hex Bolts i 18 3/8" SS Flat washers ! 18 - 5/16" x 3" SS lag bolts 18 - 5/16" SS Flat Washers Step 5: Threw post throng top r bottom of flus ing m o Fas Jack a ase Flashing Template Available for Oatey (Pictured) and standard flashings. Makes cutting in a perfect flashing easy and s ►f painless! 0 s Kit includes Fast Jack post threader ., with knob Step . Cu through shingles Fo flas i g ;flashing emplo a thus trated below i Step 6: sing a wre c secure pos in a ase Roof Trac - SOLAR MODULES f All information in this installation guide (product names and illustrations are property of Professional Solar Products, Inc. Duplication ofwhole or in part is strictly prohibited unless authorized by Professional Solar Products, Inc. TOOL LIST (WHAT YOU WILL NEED): Tilt Up Kit Installation Guide UPPER TILT ASSEMBLY FLAT ROOF DETAIL WITH END CLAMP ZAN �6*f ' ov,i:' C ' f Jel ter ��ys TILETR+ACASSEMBLY (Can also be used with Fast lack) • 3/16" Drill (Roof Pilot hole) • 3/16" Hex (T -Wrench preferred) • Cordless Impact • 1/4" Drive Socket (hinge bolt connection) The above tool list is what ProSolar recommends for instal- lation of the Tilt Up kit along with the Tile Trac attachment. For a complete guide to installing the Roof Trac mounting system please refer to the Roof Trac installation manual. professionalSCL Rproducts,, The Roof Trac Tilt Up kit is a residential tilt up accessory for the Roof Trac solar PV mounting system. The Tilt up kit inte- grates with both the Tile Trac and the Fast Jack attachment methods (explained in this installi:tion guide). Each Tilt Up kit includes the following parts (comes in boxes of 3 kits): 3-1" x 1" x 24" square tube, drilled on each end 6—Lower (unthreaded) tiWup brackets—pre tapped 3—Upper (threaded) tilt -up brackets 3—Upper (hollow) lower hinge brackets 12-5/16" x 2" Stainless Steel socket cap screws 6-3/8" x 3/4" Stainless Steel hex bolts 12-3/8" Stainless Steel bck washers Each box of tilt up kits contains 3 total kits—so components will be 3x the number of parts listed above. wwwJRoofTrac.com Page 1 Roof Trac - Tilt Up Kit Installation Guide *G 5/ 16" x 2" Socket Cap Bolt STEP 1—USING TILE TRAC UpperTilt Up Bracket ATTACH THE REAR ASSEMBLY: 1 �1 (this brdcketis threaded and nanowerthan the lower bracket) 5/16"flat washer I I Pre -tapped � I •I 1" x 1" x 24" Square Tube (ciearanodized) 3/8" Hex nut 5/16" x 2" Socket Cap Screw 3/8" Short hex stud 3/8" Lock Washer Tapped A: Attach the lower (counter -bored) tilt up bracket to the Tile Trac: Place the lower tilt up bracket (non -threaded) over the 1-1/2" stud with the serrated surface facing down. Square off with the Tile Trac upper carriage to insure a straight tilt up leg. Tighten down with a 3/8" lock washer and 3/8" hex nut. (see illustration) B: Set in the rear Tilt Up leg (square tube): Place the tilt up leg (square tube) in the center of the bracket. Align the holes of the tube with the holes in the lower bracket. Insert a 5/16" x 2" socket cap bolt with a lock washer through the holes. Do not tighten yet. 5/ 16" Lock Washer LowerTilt Up Bracket C: Attach the upper (tapped) tilt up bracket to the (this bracketis counter -bored square tube: Place the upper bracket (tapped) on top and ck �rthantheupper of the tube. Align the holes of the tube with the holes Tile Trac Carriage in the lower bracket. Insert a 5/16" x 2" socket cap bolt with a lock washer through the holes. Do not tighten yet. Tile Trac Base ,,�- UpperTilt Up Bracket `1� for lowerjoint (this STEP 2—WHEN USING THE TILE TRAC bracket is hollow) ATTACH THE FRONT LEG ASSEMBLY: 3/8" Hex nut I A: Attach the lower (counter -bored) tilt up bracket to i 3/8" Short the Tile Trac: i hex stud Place the lower tilt up bracket (counter -bored) over the I tj� 3/8" Lock Washer 1-1/2" stud with the serrated surface facing down. 5/16"x 2" -"*:washer I ^•� Square off with the Tile Trac to ensure a straight tilt up Socket cap leg. Tighten down with a 3/8" lock washer and 3/8" Tapped hex nut. (see illustration) 5/16" Lock LowerTilt Up B: Attach the upper (hollow) tilt up bracket to the Bracket (thisbracketis lower bracket: Place the upper bracket (hollow) inside counter -bored and wider of the lower bracket. Align the holes of the upper than theupperbracket) bracket with the holes in the lower bracket. Insert a 5/16" x 2" socket cap bolt with a lock washer through the holes. Do not tighten yet. Tile Trac Carriage Tile Trac Base professionalSOL'Rproducts,,,, www.Roofroc.com Page 2 .2 ion Guide. Roof. Trac Tilt:Up Kit Installat A V0 NO I 2 5/16"Iockwasiher4 I" x I" x 24" Square Tube (clearanodized) 5/ 16" x 2" Socket Cap Bolt 5/16"LockWasher ti Strut (to create grid pattern) Residential Fast.lack 5/ 16" x 2" Socket Cap Bolt STEP 1—USING FAST JACK ATTACH THE REAR ASSEMBLY: UpperTilt Up Bracket • (thisbracketisthreadedand A: Attach the lower (counter -bored) tilt up bracket to- flanowerthan, the lower bracket] the strut/beam: Place the'lower tilt up bracket, (non -threaded) over the 3/8" threaded grab nut with tne serrated surface fac ing dok:Square off with the strut to insure a straight 3/8" x 1-1/2" Hex Bolt tilt up leg. Tighten down with a 3/8" lock washer. (see not included in NO illustration) LowerTilt Up Bracket B: Set in the rear Tilt Up leg. #squire tube):. (Ws bracket is counter -bored Place the tilt up leg (square tube) in the center of the and wider than the upper bracket. Align the holes of the tube with the holes in bracket), the li3w'e'r bracket. Insert a 5/16" x 2" socket capbolt '3 /8" Bolt/flat with a lock washer through th D holes. Do not tighten Washer yet. C: Attach the upper (tapped) tilt up bracket to the square tube: Place the upper bracket (tapped) on top of the tube. Align the holes of tube with the holes in the lower bracket. Insert a,5/16" x 2" socket cap 3/8" Grab N6t b61t with a lock washer through the holes. Do* not tighten yet. UpperTilt Up Bracket for lowerjoint (this bracket is hollow) 3/8' x 1-1/2" Hex Bolt/ flatwasher 5/ 16" x :2". - Ilk,(not included in kit) Socket Cap "r -J Bolt LowerTiltUp Bracket (tlizsbracketis 5/ 16" Lock Washe counter -bored and wider than the upperbracket) 3/8" Bolt/_ Flat Washer Strut (to create grid pattern) N 3%8" Grab Nut "Residential Fast.lack- profess . ionaISOLA.Rprodu STEP 2—,WHEN USING THE FAST JACK ATTACH THE FRONT LEG ASSEMBLY: A: Attach the lower (counter-bor6d) tilt up bracket to the strut:. Place the lower tilt up bracket (non -threaded) over the grab nut with the serrated surface facing down. Sq6are off with the strut.to ensure a -ctraight tilt up leg. Tighten down with a 3/8" lock washer and. 3/8" hekbolt corn bination. (see illustration) B: Attach the upper (hollow) tilt up bracket to the lower bracket: Place the upper bracket (hollow) inside top of the lower bracket. Align the holes of the uppe'r bracket with the holes in the lower bracket. . Insert a 5/16" x 2" socket cap bolt with a lock washer through the holes. Do not tighten yet. im www.RoofTrac.com 1, Page 3 Roof TraC Tilt Up Kit Installation Guide 5/ 16" x 3/4" Hex bolt 5/16" lock , washer 3/8" x 3/4" hex bolt End Clamp 3/8" flat washer Support rail 5/16"x 2" Socket Cap Bolt / 5/ 16" Lock Washer 1" x 1" x 24" ClearAnodized Tilt up tube (rear installation) s, STEP 3—ATTACH THE SUPPORT RAILS (not included in tiltup kit) TO THE TILT UP ASSMBLY: A: Drill your holes in the support rail: Mark your spacing of the attachment points on the underside of the rail (the v -groove marks the center of the rail). With a #10 Unibit drill bit drill a 1/2" hole in the support rail B: Attach the support rail to the bracketing: 1/2" hole—drill with a Align the holes of the support rail to the holes Unitbit#10 drill bit of the upper tilt up brackets. Insert the 3/8" x 1" bolt and flat washer and tighten using 20 ft. lbs. Repeat for both upper and lower tilt up as- semblies. Channel nut �� INTER -MODULE CLAMP UpperTilt Up Bracket (this bracket is threaded andnarrowerthan the lower bracket) Please note that all module end clamps are proprietary and specially extruded to fit a specific brand of module. Since many of these tolerances are very small, we install a die line (marker) to differentiate the correct die per module frame. C: Tilt up system to desired angle: Hold the rear tilt up array to the desired angle. Tighten all bracketing connections using 20 ft. lbs. When the rear assembly is set at the de- sired angle, set the angle of the front bracket assembly and tighten using 20 ft. lbs. When installing the Tilt Up kit be sure to refer closely to the load testing and engineering specifications for adequate spacing guide- lines. MODULE CLAMP ASSEMBLY DETAIL After the support rails have been installed to the attach- ments, you are now ready to install the solar modules. There are two sets of clamps; the outside clamps (end clamp) and the inter -module clamps that install between the modules. For convenience, it is advisable to pre -thread or start the bolt, lock washer and clamp into the sliding insert prior to bringing them up to the roof. Slide the two end clamps near the end of the support rail and install your end module (first). Carefully square the module to the frame and tighten the clamps using a 1/2" box wrench or drive socket. DO NOT OVER TIGHTEN, we recommend a maximum torque of 12 foot pounds to prevent damage to the module glass. After the first module is secured, slide two inter -module clamp sets onto the first module. They are designed to stay in place freeing you up to slide and align the next module into place. Repeat this procedure until all modules are installed onto the support rail. Upon installation of the last module in the panel, install the mod- ule end clamp to complete the installation. professionalSOL Rproducts www.RoofTrac.com Page 4 Advanced Architectural Products XZ_ ICHEMUNK 16 EmCURB C VrOyetv, ' • hy: ,:• ♦ .a t.. ,t,° �i :� - - r= •' avis"- r,a. Technical DatakGuide� Polyether Techgy nolo"4&= C ection'O 13` CHEM LINK Products LLC Last Revision: 04/08/11 Telephone: 800-826-1681 Fax: 269-679-4448 353 East Lyons ° a f- ..Schoolcraft, MI 49087.. www.chemlinkinc.com 4 'f N., . Product Description E-Curb penetration, seals replace old-style metal pitch pans with versatile, precast components and pourable sealants. CHEM LINK pourable sealants can usually ' be installed in under 15 minutes and never require flashing or mechanical attachment. ?;:� 1'x o �. E-Curbs are designed for use on granulated modified . j ° `*,:..:h tr . �,• bitumen, asphalt and coal tar B.U.R. (built up roofs). 3.� • E-Curbs are specified for PVC, EPDM, PIB and TPO * "`' single ply roofing. CHEM LINK TPO Primer is required E-Curb System Components A for use with TPO. (1) E-Curb exterior rings; ' When installed properly, this system forms a durable, (2) M-10 Structural Adhesive/Sealant used for waterproof rubber seal around penetrations. An bonding the E-Curb and sealing/priming the' extended warranty against leaks is activated with penetration; submittal of a completed warranty card. ' Special Characteristics (3).1-Part® "moisture cure" pourable sealer, used to • Rapid installation - reduces labor significantly.-form a durable, water-tight seal around the roof • Excellent adhesion to most roofing materials. penetration. No flashing or mechanical attachment required. E-Curb precast form components are composed of Sealant is flexible to minus 40° F. light weight gray vinyl resin. The E=Curb is 2" high • System is stable to 200° F. and has an inside diameter of 3, 6 or 9 inches. The ` 1-Part® accommodates movement and is curved outer surface is impervious to ice, corrosion, suggested for use on all granulated membranes and details with excessive movement. UV (ultraviolet light) and ponding water.' - Restrictions M-10 Structural Adhesive/Sealant is a durable, self- ' • Do not apply below 30° F. fixturing, moisture cure mastic. Two cartridges of • Do not use on Hypalon or smooth APP modified gray M-1 are supplied in each kit and E-Curb , . • bitumen membrane. For smooth APP, melt down carton. an overlay of granulated APP before installation. 1-Part® is a light, gray, highly flexible, self-leveling • CHEM LINK TPO Primer must be used for TPO moisture cure pourable sealer.that eliminates mixing... applications. It is also 100% solid .rubber, has very low VOC • Do not prime bonding surfaces with asphalt primer! content, will not melt or shrink, and is resistant to • Do not use asphalt cement r a "night sealant," deterioration. It is supplied in 10.1-oz. cartridges or instead use M-1®for this purpose: 1/Z gallon pouches.. Unused sealer can be capped and reused. ROOFM OONTRACTORS ASSocygnON T• NAMAAL -� ` - MEMBER I\b'TITUTF: Remove all previously applied caulk, mastic, cement, asphalt and other contaminants from penetrations with a wire brush. Brush away all gravel or loose granules. Seal the base of each penetration with M-10. Coat penetrations with M-1® to 3" above the roofline. 9 C Hold a section of E -Curb, flat side up, and apply a Y" bead of M-10 to the entire bottom perimeter. Apply 2 additional %" beads of M-10 down the center of the section. Do not tool the beads flat. Place the E -Curb section on the roof surface to form a half circle around the penetration(s). Press down firmly until M-10 extrudes from the outside edges. 9: A +,} 4..' j r`$LA' +fF 4, t Apply M-10 to the second section of E -Curb as described above. Place Cut tip off 1 -Part® tube at widest point on plastic nozzle and the second section of curb on the roof surface to form a circle with the pierce the foil seal. Insert into quart caulking gun and pump, first section. Press firmly in place until excess adhesive extrudes from, E -Curb full, or when using a 1 -Pae pouch, remove cap,, the outside edges. Apply a bead of M-18 around the outside base of the pour, squeeze out excess air and reseal. installed E -Curb, and tool to form a smooth fillet. For "non"- E -Curb', Note: To provide an adequate rubber seal, maintain a V penetration seals, add M-1® to scarf joint surfaces and tool smooth. distance between penetrations and inside edge of E -Curb. IMPORTANT NOTICE Except where prohibited by law, CHEM LINK makes no warranties, expressed or implied, statutory or otherwise, including but not limited to, any implied condition or warranty of merchantability or fitness for a particular purpose. User is responsible for determining whether this CHEM LINK product is fit for a particular purpose and suitable for user's method of application. LIMITATIONS OF REMEDIES AND LIABILITY If this CHEM LINK product is proved to be defective, the exclusive remedy at CHEM LINK's option shall be to refund the purchase price or to repair or replace the defective CHEM LINK product. CHEM LINK shall not otherwise be liable for loss of damages, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including negligence, warranty or strict liability. CHEML1NK@J.,& Advanced Architectural Products Contractor Hot Line www.chemlinkinc.com Hai H®ng Structural Engineering Services .. , { s f - , . T _, : ' June 4, 2012 • , , f T y •' 'Calmonte Corporation +. s• w l' r n e DBA Solar Warehouse . t `.R 9628 Valley'Blvd. Rosemead, CA 91770 r -Phone: (626)579-3288 "4 ' .. q . Li R • , f .:f s ` 4.. Attn: Engineering Department, Subject: Engineering Certification for SWM Solar Racking Installation G-xide • " (Version 12.5.V1) _ ,. f�� Hai Hona, being a registered Profess ional Ehe'State of California, ' • P.E. # C68610, and being duly competent as regards photovoltaic (PV) mounting ' systems design and construction, has reviewed SWH Solar Riclting Installation ' Guide (Version 12.5.V 1) " Part: l Procedure to Determine the Design.Wind Load",' Y, F _ ' and ""Part2 .Procedure to Select Rail Span and Foot Spacing'. ` . �, �• i By attached'.P.E. my seal,'I certify that the procedures which are used to deterriine ' the calculation of design wind force; load combinations,'applied loading, 'rail ;. r• 1 selection, data and analysis contained within this installation guide are based an and �. ` comply.with the design criteria specified in: - 1. ' 2009 International Building Code; by International Code Council, Inc, 2009 ' .2. 2010 California Building Code, by California Building Standards ' ` Commission, 2011 3. Aluminum Design Manual: Specification and Guidelines for Aluminum ' Structuies, by The Aluminum Association; 2005. p .. r 1 ;This engineering certification shall not be construed as relieving the manufacti .rer'or` installer of their responsibilities' liabilities or contractual obligation. It is the irrtaller's • • f , ' responsibility.to verify that -the existing building structure to which'the PV mounting ` • s stem is to be fixed is adequate to support the load forces induced b PV mounting` .,,system1?p, ystem: _ s q , Y . �V " Please contact me if you should have any questions' H .q faithfullyYours _C68610 / Hai i I g, PE • Hai Hong P.E • , 4439 Mission Hills Dr. Chino Hills CA 91709. Phone: 909.606.8540 �• .y . /' tet. H ' L •' ... -- s - .. WAREN r� i SWH Solar Mount L -BRACKET . L -Bracket material: 6005-T5 Extruded aluminum alloys i Part No. MR -SW -LB -90, MR -SW -LB -90B • Maximum Tensile: 38ksi, yield: 35ksi RAIL • Finish: clear or black anodized; . Bolt & nuts material: 304 stainless FLANGE NUT,,��- -�_ • Mid clamp weight: 0.24lbs Allowable and design loads are valid when components are 1 assembled according to authorized SWH documents . For the rail to L -Bracket connection: r " �`�';,.> • Assemble with one STM F593 %"-16 hex bolt and a ASTM %" serrated Flange Nut Ressistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited HEX BOLT L-BRACKE e 3.00 3Y %rT FOR Y 'a WW.-ie441F.. -• A t, 2.00 Dimensions specified in inches unless noted NOTE: Loads are given for the L -bracket to rail connection only; be sure to check load limits for standoff, lag screw, or other attachment method Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, m Sliding, Z± 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1 1325 (5893) 2.461 2004 (8913) 0.615 Traverse, X± 486 (2162) 213(949)1 2.28 323 (1436) 0.664 SWH Solar Mount Splice Bar o Splice bar material: 6005-T5 extruded aluminum alloys Part No. MR -SW -SB -01, MR -SW -SB -01 B a Maximum tensile: 38ksi, yield: 35ksi • Finish: clear or black anodized RAIL - _ i.,---, - ,a. • Self -tapping screw material: 304 stainless M�( • Splice bar weight: 0.36 lbs Allowable and design loads are valid when components are assembled SPLICE ,. ,,. according to authorized SWH documents y For the Splice bar to Rail connection: • Slide splice bar in groove on between two rails • Use 4-8 1/a" self -tapping screw to join Splice bar to both rails } 4�----------_�� safet • Ressistance factors and y factors are determined according to part 1 _ section 9 of the 2005 Aluminum Design Manual and third -party test RAIL '° results from an IAS accredited laboratory . A thermal break is required every 40 feet of continously connected rail. For additional concerns on thermal breaks in you specific project, please consult a licensed structural engineer. y l Q • Expansion joints prevent buckling of rails due to thermal expansion. .. .. Splice bars may be used for thermal expansion joints. To create a thermal expansion joint, slide the splice bar into the 1/2" between the rail segments. Secure the splice bar with two screws on one side only. Foot- ings (such as L -brackets or standoffs) should be secured normally on both sides of the splice. No PV module or mounting hardware component SELF -TAPPING SCREW SPLICE BAR should straddle the expansion joint — -y h t V •err' ��pp''n� SWIH Solar Mount Rail Part No. MR -SW -SR -10, MR -SW -SR -12, MR -SW -SR -14, MR -SW -SR -14B MR -SW -SR -17 4 • SLOT FOR T -BOLT OR Y4" HEX HEAD SCREW fr��r fSLOT FOR 3�" HEX BOLT 2.25" k � Y' 3 SLOT FOR ;+ m X ' HEX BOLT •w :r 750" SWH Solar Mount Rail .t{ , wY. { -< Typical Composition • t MLARWAREHOUSE' 3 f a Rail material: 606:3-T6 Extruded aluminum alloys a Finish: Anodized Clear or Black Properties Units Solar Mount Beam Height in 2.25 Approximate Weight plf 0.700 Total Cross Sectional Area int .588 Tensile Strength kgf/mm2 19.4 Yield Stregth kgf/mm2 16.9 Elogation (G.L.=25mm) % 17.2 Material % Si % Fe % Cu % Mn % Mg % Zn % Ni % Cr % Pb % Sn % Ti % Al 6063 0.3972 0.2679 0.0469 0.0666 0.4936 0.0436 0.0056 0.0205 0.0010 0.0044 0.0188 98.6 r • ' SOLAR MOUNT RAIL t t+ a f ~ Y L -BRACKET a• T Solar Warehouse is a registered trademark and DBA of Calmonte Corporation. 9628 Valley Blvd., Rosemead CA 91770 (626) 579-3288 www.calmontecorp.com 1 - f Hardness (HR15T) 71 Material % Si % Fe % Cu % Mn % Mg % Zn % Ni % Cr % Pb % Sn % Ti % Al 6063 0.3972 0.2679 0.0469 0.0666 0.4936 0.0436 0.0056 0.0205 0.0010 0.0044 0.0188 98.6 r • ' SOLAR MOUNT RAIL t t+ a f ~ Y L -BRACKET a• T Solar Warehouse is a registered trademark and DBA of Calmonte Corporation. 9628 Valley Blvd., Rosemead CA 91770 (626) 579-3288 www.calmontecorp.com 1 - f r • ' SOLAR MOUNT RAIL t t+ a f ~ Y L -BRACKET a• T Solar Warehouse is a registered trademark and DBA of Calmonte Corporation. 9628 Valley Blvd., Rosemead CA 91770 (626) 579-3288 www.calmontecorp.com 1 - f SWHSOLAR MOUNT PARTS DATASHEETS + SWH Solar Mount End Clamp • Part No. MR -SW -EC -35, MR -SW -35B, MR -SW -EK -40, MR -SW -EK -40B, • MR -SW -EF -45, MR -SW -EF -456, MR -SW -EE -50, MR -SW -EE -50B • BOLT �-�. • NUT ----.... .... ...... S y 4 MODULE- END ODULE END CLAMP' f RAIL ti4:MUN F Applied Load Direction VAPIES N Y rnicxass 1 , W X Dimensions specified in inches unless noted SWH Solar Mount Mid Clamp Part No. MR -SW -MC -20, MR -SW -MC -20B End clamp material: 6005-T5 extruded aluminum alloys Maximum tensile: 38ksi, yield: 35ksi Finish: Clear or Black Anodized Bolt & nuts material: 304 stainless End clamp weight: varies based on height: 0.09-0.10 lbs Allowable and design loads are valid when components are assembled according to authorized SWH documents Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SWH solar mount rail to retain a module in the direction indicated Assemble mid clamp with one 1/4"-20 T -bolt and one 1/4"-20 "-20 ASTM F594 serrated flange nut Use anti -seize and tight to 10ft-lbs of torque Ressistance factors and saftey factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory Modules must be installed at least 1.5 in from either end of a SWH solar mount rail Ultimate Load Factor, Load Facto BOLT \ NUT � t ` � �✓/� . RAIL MID CLAMP / MODULES 1.00 DG ,VICE v.ECVrE6n i40i5uu55 -� Y Dimensions specified in inches unless noted • Mid clamp material: 6005-T5 extruded aluminum alloys • Maximum Tensile: 38ksi, yield: 35ksi • Finish: Clear or Black Anodized • Bolt & nuts material: 304 stainless • Mid clamp weight: 0.0096 lbs • Alllowable and design loads are valid when components are assembled according to authorized SWH documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SWH solar mount rail to retain a module in the direction indicated • Assemble mid clamp with one 1/4"-20 T -bolt and one 1/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tight to 10ft-Ibs of torque • Ressistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory Applied Load Direction Average Ibis (N) Allowable lbs (N) Safety FS Design lbs (N) Resistanc e r m Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, X± 1194 (5312) 490 (2179) 2.44 741 (3295) 0.620 BOLT \ NUT � t ` � �✓/� . RAIL MID CLAMP / MODULES 1.00 DG ,VICE v.ECVrE6n i40i5uu55 -� Y Dimensions specified in inches unless noted • Mid clamp material: 6005-T5 extruded aluminum alloys • Maximum Tensile: 38ksi, yield: 35ksi • Finish: Clear or Black Anodized • Bolt & nuts material: 304 stainless • Mid clamp weight: 0.0096 lbs • Alllowable and design loads are valid when components are assembled according to authorized SWH documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SWH solar mount rail to retain a module in the direction indicated • Assemble mid clamp with one 1/4"-20 T -bolt and one 1/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tight to 10ft-Ibs of torque • Ressistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third -party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, m Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Z± 1 63 (279) 1 14 (61) 4.58 21 (92) 0.330 Sliding, X± 142 (630) 1 52 (231) 2.72 79 (349) 0.555 'Smart niche 3 we create smart grids' Ns A" 1-21 0+c8. SmartMeter. SmartSynch's residential smart metering solution features a communica,7ions module that is integrated into the GE 1-210+c electricity meter. The 1-210+c SmartMeter communicates over an existing cellular network with the SmartSynch Transaction Mona! ement SysteMT14 '(TMS) or other C12.21 .head -end system (such as MV -90) and complies with ANSI C12.19 Ron protocols for data storage and transmission. The 1-210+c SmartMeter is a single-phase electronic watt-hour meter for;.jse in residential and light commercial service locations. The 1-21 O+c' s key features include Time of Use, Demand and Load Profile, Remote Connect/Disconnect, and C12.22/ C12.21 compatibility. The 1-210+c SmartMeter also includes an optional Zig Bee® wireless component for in -premise communications and an optional Badger ORiON® wireless component for gas and water. reads. Functions & Fedtures, Wireless Commufiications Hardware Components - GPRS • Remote Disconnect/Reconnect . ZigBee® Radio Control Mockile Board (RCM) tE - Badger ORION®' Capacitor Storage Bank (CSB) lki6l Advanced Metering Functionality • •GSM/GPRS N�oderr & Remote Disconnect/Reconnect Zig Bee Transceiver -Flexible Two -Way Data Retrieval -.Badger ORION Receiver - Scheduled & On -Demand Reads • Internal Antenna - Inte rval Reads (5, 15, 30, 60 minutes) Operating Ranges Real -Time Interval Reads Automated Register, Self -Read & TOU Temperature • Demand Resets •Operating' [-40°C, -85°C] Real-Tirrie Event & Alarm Retrieval •Meter Transmission (GPRS): -40°C, +850C] • Real -Time Power Outage & Restoratiorii. Humidity Service Diagnostics & Tamper Detection -O%to95%non-condensing , Tilt Detection Accuracy • Meter Clock Synchronization • Meets ANSI 12.20 fo•- accuracy class 0.5% SmartMeter Status Display. 1 Automated Meter Registration Regulatory & Industry Specifications Secure & Encrypted Data Transmissions FCC Part -15 Class B It Bi -Directional Metering , & ANSI C37.90.1 - 198?: (SWC) - Over -The -Air SmartMeter Module Firmware - ANSI C12.20 (Class C.5) - 1998 Upgrade • PTCRB Certified Supported Meter Forms N etwork Carrier Cerilified l9smartsynch, inc. • class 20: 3S, 4S Measurement Canoda Certified. .4400 Old Canton Road , 1. 1 1 •Class 100: IS • Jackson, Mississippi 39211 1-888-362-1780 Class 200: 2S, 12S, 25S Class 320: 2S www.smartsynch.c6m • See back page for Supported Forms With Remote Disconnect Hardware Specifications Smart Synch Integration The SmartMeter module is a fully integrated, under -the -cover option inside the 1-210+c meter. The 1-210+c SmartMeter is shipped as one complete unit, ready for field deployment. Version and Compatibility Information 1-210+c Meter Hardware: Supported meter forms, classes, and types, equipped with battery 1-210+c Meter Firmware: Latest fully supported SmartModule: 1-210+c GPRS SmartMeter Module SmartSynch TMS: Version 6.0 or higher About SmartSynch: Headquartered in Jackson, Miss., SmartSynch has been developing successful Smart Grid Intelligence solutions for the utility industry since 2000. The company's clean -tech innovations in the two-way delivery of real-time energy usage data over cellular networks (AT&T, Rogers, etc.), in lieu of private network build -outs, have to date simplified SmartMeter deployments for 150 major North American utilities, while enabling green -energy initiatives and delivering significantly higher Returns on Resources. Unlike proprietary, closed -architecture solutions, SmartSynch's SmartMeters represent future -proof investments in technology. The standards-based IP connectivity enabled in every SmartMeter deployed makes them adaptable and remotely upgradable to support today's sensor and communications needs, as well as tomorrow's opportunities, better than any alternative. Hardware Component Description Radio Control Module Board (RCM) 32-bit ARM processor, 256K RAM, 512K flash . Capacitor Storage Bank (CSB) Supplies peak power for data transmissions and all functions during power outages - no batteries required GSM/GPRS Modem GSM modem communicates with head -end using GPRS and SMS services ZigBee Transceiver Wireless component for in -premise two-way communications Badger ORION Receiver Wireless component for receiving gas and water reads Internal Antenna Flexible dual frequency GSM antenna for the modem Temperature Ranges Supported Meter Forms With Disconnect Operating: [-40°C, +85°C] Class 20: 3S, 4S Class 100: 1 S Class 100: 1 S Class 200: 2S, 12S, 25S Transmission (wireless): [-40°C, +85°C] Class 200: 2S, 12S, 25S Class 320: 25S Class 320: 2S Humidity Range 0% to 95% non -condensing Regulatory &Industry Certifications FCC Part 15 Class B Accuracy ANSI C37.90.1 -1989: Surge Withstand Capability (SWC) ANSI C12.20 (Class 0.5) - 1998 Meets ANSI 12.20 for accuracy class 0.5% PTCRB Certified Measurement Canada Certified Network Carrier Certified Input/Output Signal or Interface Definition/Values Module Power Input Voltage 120 - 240 VAC Meter Serial Interface 3.3V / TTL compatible asynchronous Integration The SmartMeter module is a fully integrated, under -the -cover option inside the 1-210+c meter. The 1-210+c SmartMeter is shipped as one complete unit, ready for field deployment. Version and Compatibility Information 1-210+c Meter Hardware: Supported meter forms, classes, and types, equipped with battery 1-210+c Meter Firmware: Latest fully supported SmartModule: 1-210+c GPRS SmartMeter Module SmartSynch TMS: Version 6.0 or higher About SmartSynch: Headquartered in Jackson, Miss., SmartSynch has been developing successful Smart Grid Intelligence solutions for the utility industry since 2000. The company's clean -tech innovations in the two-way delivery of real-time energy usage data over cellular networks (AT&T, Rogers, etc.), in lieu of private network build -outs, have to date simplified SmartMeter deployments for 150 major North American utilities, while enabling green -energy initiatives and delivering significantly higher Returns on Resources. Unlike proprietary, closed -architecture solutions, SmartSynch's SmartMeters represent future -proof investments in technology. The standards-based IP connectivity enabled in every SmartMeter deployed makes them adaptable and remotely upgradable to support today's sensor and communications needs, as well as tomorrow's opportunities, better than any alternative. i . I SCREW: E1276 I CAT. NO.: I MASS:.052 LBS. ISURFACE AREA: 2:738 IN2 ISTUFFER SHT: FORM 12 .375±.015 [9.53±.381 .213 - [5.41] MATERIAL:COPPER, XOC7309 TOLERANCES -UNLESS OTHERWISE SPECIFIED DWG. N0. 2 PL DEC. ±.015 TRUE C.L.t.015 PLATING: SEE CHART 3 PL. DEC. ±.010 ANGLES ±1 G0977 MARKING: ONI GBL-4DB, 4-14, CU, DB DRAWN BY: CLH SCALE: 3:1 SHEET 1 OF 1 DATE: 7/27/2007 SIZE: A CORP. CELL:ABM REV. DESCRIPTION t' Cat a GBL -4®B 0.218 THRU G B L-4 ®BT E1276 SCALE 1.: 1 OPENING MUST SLIP A 0.250 PIN .825 [20.96] hill I_ ^ r--- 1.150 [29.21] Li THE INFORMATION CONTAINED WITHIN THIS DOCUMENT IS h ' a I .470 [11.94] L- v.J .185±.005 [4.70±.131 PART NUMBER PLATING MARKIN G0977AOOB BRIGHT DIP GBL-4DB,4-14, G0977AOOT EL -TIN GBL-4DBT,4-14 TO ILSCO AND MAY NOT BE DISCLOSED WITHOUT PRIOR WRITTEN CONSENT P.O. Box 3300, Term." X A London, Ont. Canada . N6A 4 (519) 681-2-2 140 1-800-265-1815 Fax (519) 681-2156 KRALOY t A DIVISION OF MULTI FITTINGS CORP. :i KRALOYO PVC ELECTRICAL CONDUIT FITTINGS LETTER OF COMPLIANCE 4507 LeSaint Court Fairfield, Ohio USA 45014 (513) 942-9910 1-800-523-3539 Fax (513) 942-9914 Scope: This letter of compliance covers Multi Fittings requirements for PVC Electrical Conduit Fittings, Outlet Boxes,,Covers and Bends for use with Schedule 40 and 80 PVC conduit. These products meet or exceed performance standards set by the American Society of Testing and Maierials (ASTM), CSA International (CSA), .the National Electrical Manufacturers Association (NEMA) and Underwriters Laboratories Inc. (ULI). Kraloy. PVC Electrical Conduit Fittings, Outlet Boxes, Covers and Bends are typically used for industrial, commercial and residential applications. These applications include residential single and - multi family dwellings, fish processing plants, bridges and tunnels, car washes, sewage treatment plants, pulp and paper, utilities, cable, food processing plants, agriculture,' airports, marinas, water treatment plants, street and highway lighting, and communications. Material: Rigid Poly (Vinyl Chloride)(PVC) used in the manufacturing of Kraloy PVC Electrical Conduit Fittings, Outlet Boxes, Covers and Bends is compounded to give superior phys.cal properties in the. finished product. All products are grey in color. Molded Fittings. Boxes and Covers: Molded Kraloy PVC Electrical Conduit Fittings, Outlet Boxes, and Covers conform to the following standards when applicable: CSA C22.2 #18 "Outlet Boxes, Fittings, and Associated Hardware" CSA C22.2 #40 "Cutout, Junction, and Pull Boxes " CSA C22.2 #42 "General Use Receptacles, Attachment Plugs, and Similar Wiring Devices" CSA C22.2 #85 "Rigid PVC Boxes and Fittings" CSA C22.2 #94 "Special Purpose Enclosures" CSA C22.2 #211.0 "General Requirements and Methods of Testing Nonmetallic Conduit" CSA C22 2 #227.1 "Electrical Nonmetallic Tubing" CSA C22.2 #227.2 "Flexible Liquid -Tight Nonmetallic Conduit" NEMA TC3 "PVC Fittings for Use With Rigid PVC Conduit and Tubing" NEMA TC9 Fittings for ABS and PVC Plastic Utilities Duct for Underground Installation" NEMA 250 "Enclosures for Electrical Equipment (1000 Volts Maximum) UL50 "Enclosures for Electrical Equipment" UL514B "Fittings for Cable and Conduit" UL.514C "Nonmetallic Outlet Boxes, Flush -Device Boxes, and Covers" Note: Conduit Fittings and Boxes meet Federal specification WC -1095A and Corps of Engineers specification CE -3030:01. Kraloy Junction Boxes are UL approved for the following enclosure types; o� K"RALOY® Page 2/... PVC Electrical Conduit Fittings, Outlet Boxes, and Covers Junction Boxes - 4x4x2 & 4x4x4 — Type 1, 2, 3, 3R, 3S, 4, 4X, 5 & 6P. Type 2 and 5 can be marked "drip tight" Type 3 or 3S can be marked "rain tight" or "dust tight" Type 3R can be marked "rainproof' Type 4, 4X or 6P can be marked "rain tight" or "water tight" Type 4X or 6P can be marked "corrosion resistant" Type 5 can be marked "dust tight" Junction and Pull Boxes — 4x4x4, 6x6x4, 6x6x6, 8x8x4, 8x8x7, 12x12x4 & 12xl2x6. — Type 1, 2, 4, 4X, 5, 6 & 6P. Type 2 & 5 can be marked "dripped tight" Type 4, 4X or 6P can be marked "water tight" or "rain tight" Extruded Conduit and Bends: Extruded Conduit used for Bends conforms to the following standards when applicable: Products sold in Canada: CSA C22.2 #211.0 "General Requirements and Methods of Testing Nonmetallic Conduit" CSA C22.2 #211.1 "Rigid Types EBI and DB2/ES2 PVC Conduit" CSA C22.2 #211.2 "Rigid PVC (Unplasticized) Conduit" Products sold in the United States of America: NEMA TC2 "Electrical Plastic Tubing (EPT) and Conduit (EPC -40 and EPC -80) " UL6.51 "Schedule 40 and 80 Rigid PVC Conduit" Marking: Kraloy PVC Electrical Conduit Fittings, Outlet Boxes, and Covers are marked in accordance with CSA requirements for sale in Canada and UL requirements for sale in the U.S.A. Yours truly, i Frank Yorio Senior Vice President, Operations Issue Date: 2010-07-14 LIN Junction Boxes 4. 0M • Junction boxes are supplied with P o ` threaded brass inserts, brass • " P screws,, PVC gasketing and M , - In mounting feet. Nylon and stainless ' steel screws, and larger. sizes'of . fabricated junction boxe's,,are available,upon request. 11 ° L ; B sq A sq o .. T ~ CSI T i Size part Part A sq. -B sq. C D H' T' ' w in. Number Number . - ,_ • (• ) �. (inches) v O 4 x4 x2 JB442 078242 4.375'4.000 2.020 2.200 4 0.187 ` • L <}O 4x4x4r-'JB444 078243 4.375 '4.000 4.000 4.187 4 0.187 p4O 4 x4 x6 JB446 078244 4.000 3.675 6.000 6.225 4 0.225 " 5 x5 z2 JB552 078245 5.000'4.680-2.000'2.000 4 0.155 6 x6 x4 •'JB664 078246 6.375 6.000 4.000 4.187 4 0:187. �" ': { 6 x6 x6 . JB666 078247 6.375 6.000 6.000 6.187 4 0.187` .,�" - ' �' • p4 8x8x'4J6884 0782488.812 8.000 4.0004.187'4 0.187 8,x8 x7 � JB887 078249 8.812 8.000' 7.000 7.175 4 0.250 • 4412x12x4 JB12124.'078250.12.687 ,12.000 4.000 4.250 8 10.250 0012 x12 x6 JB12126 078251 12.687 12.000 6.000 6.250 `8' 0.250 �00012z12x8JB1 2128.078252 12.580 12.085_8.025 8.250 8 0.225 *w J *NEMA 1, 2,'3,'3R, 4, 4X, 5",'6P *. hx OONEMA 1, 2, 4, 4X, 5 6,61P ^ . pOONEMA 1, 2, 3, 4, 4X, 6P, 12 & 13 ' Note: Boxes include cover, gasket and screws.. _ External mounting feet are supplied with all sizes except ` JB444 and JB446. ., = te r ® r• � _ •r � 1. a CSA, ULI RIGID PVC CONDUIT FITTINGS - KRALOY 6X6 JUNCTION BOXES O B A n ., 0 b ISSUE DATE: DATE D'EMISSION: 2009.04 30 SUPERCEDES: REMPLACE: 2003 05 15 4 !-'N A F'E B D cl, R mr=i EUCT PART I-----T(mm) NUMBER NOMINAL SIZE A INSERT CODE B VOLUME D (in) E (cu. In) . (in) (in) (mm) (in) (mm) (in) (mm) (in) (nim) 078246' JS 664 6 155 6.000 152 6.375 162 4.187 106 4.000 102 078247 JB 666 6 155 6.000 152 6.375 162 6.187 157 6.000 152 178064 JB 664 6 155 6.000 152 6.375 162 4.187 106 4.000 102 PRODUCT CODE PART NUMBE IR NOMINAL SIZE GASKET CODE INSERT CODE SCREW CODE VOLUME (in) (mm) (cu. In) . (Cu. cm) 078246 JS 664 6 155 072492 072539(8) 072513 (8) 138.0 2263.2 078247 JB 666 6 155 072492 072539(8) 072513(8.) 211.0 3460.4 178064 JB 664 PTf1AIC0 U11Tu w c+uA 6 .— 155 072492 072539(8) 072513 (8) 138.0 2263.2 _owv1% 1 IIlvV 9- , 1, V.71 141 l Page: KRALOY — 27.1 y. =r _ i.. t .i.-3 t' •'. •. w � F1'' -. �-' df'%L.. Y� � "+' r,e,is5'7 •'K, 5 } Y 1• S of r ' x �� t ` ,F t w r+ • x c� Mel.Cn ' ` •�,� "� G IRest entfalNYarra� � " 08 ci -. r,. \ .' 3, - � , '• Ume Branch reek 1dwarra, y `. Loadcenter rra�tyexte dsito�years e _ ' r i ns�t�allahono a Cuder- a me su ge pr ctar. $100;000'fim d arrarrty on tg "rrterru gtload�" " d���l�� �', �,�--s•'a.•�:.5 µ cerrte�rs-�' off`, ti � ��.,-• The1"1 �' ✓ Full hne ofsingLe-phase ark res hese 240 a`: 9 maximum loadcentem = ^r r wT ✓ Commercial grade copper bus cor Ghon for �• a superior conductivity ✓ All metal backpan for durabtftry and reliable" breaker mounting. vF b (_ 1v Flexible splittable neutral system or single movable :a- % s?. ," '�} neutral for ease of wiring. ✓ Available up to 100 kAlCto meeell application Y,.,requirements: r .� _ ✓All 4thru'42circuit outdoor loa8centersfeature ' ` y � r ; . ` side -hinged door for easy agq!B . ' t ' ✓Full line of plug-on.and hardwired surge products available.gv no s CH Residential Breakers_ _ 4 ` a3 ;';• ; ✓ CHbreaker'tdps to off to elim no nuisance c�' call-backs. f r t ✓ CHP breakers availablevwth'cer �e�trip poson forLAJ industrial aiiblications $� k r Unique breakerfootpnntto ensure UL compliance t of retrofit breakers r'7ype_CH_15 and 20 amp breakers eature low Magi setnngs for_.tmproved,protection. ' ✓ Type CH 15 thru 30 amp3 er Akers featoie load lugs r �.. ,• rated for (2)X14-#16,wireirmorewiriingflexibility. ✓ Full line of special application breakers such as .: ' GFI, Arc Fault Circuit firt pters, HID rated, and Uj R. @ #, BR U adc,enter ' � u " - ,aloe Sfanaar` N�ghes d,... The. Uj.. .. 999 .... r ... .. ,J - ��C' {�•�y� :yam._ ''tr '.J T N �} �•, w. r� z CUTLER -HAMMER NEW 2 THRU 8 CIRCUIT CH LOAOCENTERS 2 Circuits 40 and 70. Amperes SURFACE OUTDOOR RUSH 2 Circuits — 125 Amperes ; r t y SURFACE 2 Circuits 125 Amperes SURFACE OUTDOOR FWSN ;y s cop Alr B°s way ckaged dually Pa • '•' Indivi ode in u s.A. l 6 IinAual Lahelln9 _�ZOOR RUSH Main Ampere Rating Type of Main Maximum Number Enclosure Type Previous Catalog Number N Catalog Number Boxsize Wire Size Range forAUCu 31Ftnch flgmm) Clrcults 2 40 Spaces 414-2 Outdoor MUM CHWORP0 5R Indoor/Flush CH21.70F MUM 5 125 MLO 2 Single -Phase, 3 -Wire, 120/240V AC — Single Neutral 40 MLO 2 40 Indoor/Surface CH21-40S CH21.40SP 5 ;r14-6 Outdoor CH2L4OR CH21.4013130 5R Indoor/Flush CH21-401' CH2L40FP 5 70 MLO 2 40 Indoor/Surface CH21-70S CH21.70SP 5 414-2 Outdoor MUM CHWORP0 5R Indoor/Flush CH21.70F MUM 5 125 MLO 2 40 Indoor/Surface CH21-125S CH21.125SP 6NEW 414-1/0 Outdoor CH21-125R CH21.125RP® 6RNEW Indoor/Flush CH21.125F CH21_125FP 6NEW 125 MLO 4 80 Indoor/Surface CH41.125S CH41_125SP 7 414-1/0 Outdoor CH41-125R CH41.125R13® 7R Indoor/Flush CH41.125F CH41.125FP 7 125 MLO 8 16m Indoor/Surface CH8161-125S CHBL125SP 7 A-1/0 Indoor/Surface CH81.125S CH81.125SP 7 Outdoor CH8161-125R CH8L125RP® 7R Outdoor CHBL125R CH81_125RP® 7R Indoor/Flush CHB161.125F CH8L125FP 7 Indoor/Flush CHBL125F CH8L125FP 7 Three -Phase, 4 -Wire, 208Y/120V AC — Single Neutral TLO 6 120 Indoor/Surface CH6L3125S ICH61.3125SP 1 7 1 414-1/0 Outdoor CH61.3125R CH61.3125RP® 7R Indoor/Flush CH61.3125F CH6L3125FP 7 0 Use CHNT type twin breakers for full circuit utilization. 0 Hub not included. Order Type DS hub separately. New EXCLUSIVE Decorator Cover! (For use with stud -width 11-42 space loadcenters.) Yu See It... 21 Loadcenters .Now You non�t. ImPrOye Covers oecarato s ad eutet space Aesth etWith CN the Li ing FO ousted Within finish is perfect M ext White T�onstructWal,p,pered in Nevv ed or Easel,,hAny Oecor to Ma See SA.31A.01.S.E for complete details. All of the Sizes You Need... 100G) C 0@o ...and Plenty of Knockouts! , Boz Dimensions in Inches -Box Only Dimensions in mm -Box only Code Diameters in Inches Diame:ersinnun Size Height Widdt Depth Height I Width I Depth NEMA Type 1 Indoor Enclosures A 1/2 - - - 127 - - - B 1/2 3/4 - - 12.7 19.0 - - 5 9-7/16 4-1/2 3 239.6 114.3 762 6 12 6-7/8 4-1/2 304.8 174.6 114.3 C 1/2 3/4 1 - 12.7. 19.0 25.4 - D 1/2 3/4 1 1-1/4 12.7 19.0 25.4 31.7 7 13 11 3-W16 330.1 279.3. 90.5 F 3/4 1 1-1/4 1-1/2 19.0 25.4 31.7 38.1 NEMA Type 311 Outdoor Enclosures I G 1 1-1/4 1-1/2 - 25.4 31.738.1 - 5R 9-7/16 4-1/2 3 239.6 114.3 76.2 H 1 1-1/4 1-1/2 2 25.4 31.7 38.1 R. 6R 12 6-7/8 4-1/2 304.8 174.6 114.3 7R 13 11 3-9/16 330.1 279.3 90.5 (De W o ° o©. 00 o Box 5 © Box 6 O O O O � 0 O O ©\ Cn. O O O O(90. pOOHub Box SR Box 6R W o 0 0, o 00 Another Cutler -Hammer EXCLUSIVE! Door t :•''.° . �.: ... ....: .. . da.Hin9ed $ Circuit SihN te rs 14t a ' I n On A r LDadc. Dyed Outdoo ngnrnpr"{ I N� Wn lar t 1-x cc Ease of r Instalk i� safety f° Copyright Eaton Corporation, 1998. All Rights Reserved OO o9�Hub o Boc 7R O© (D O @@@ G 0@o O © o©© n Loadcenters 14 0 100G) C 0@o B Q Box 7 O © O OO o9�Hub o Boc 7R O© (D O @@@ G 0@o O © o©© n Loadcenters 14 0 . __ CUTLERAAMMER_NEW 2_T_HRU .8_CIRCUIT_ BR_LOAUCENTERS . 2 Circuits 2 Circuits 70 Amperes 125 Amperes Y, } SURFACE otrmam FLUSH SURFACE OUTDOOR FLUSH 2 Circuitska9ed ally PSG 125 Amperes n -' du Indy1 r-011 ; Md I Labeling gilingua -• „SURFACE '� ouroaaR •• FLUSHV11TH000R 60 Main Typeof Maximum Number Enclosure Previous �,A' Boz Sim Wire Size Ampere Main Type Catalog Number NEW Range 2 1.1nch clrcults Rating I Amm) Catalog Number forAl/Cu Outdoor BR24LGONAR BR26ONARP 5R Spaces 70 Single -Phase, 3 -Wire, 120/240V AC —Single Neutral 60 Non- Auto Breaker 2 — Outdoor BR24LGONAR BR26ONARP 5R .18-2. 70 MLO 2 4 Indoor/Surface BR24L70S BR241.70SP 5 €8-2 Indoor/Surface BR24L70SG 1311241.70SUM 5 Outdoor BR24L70R BR24L70RPO 5R Indoor/Rush BR241_70F BR24L70FP 5 Indoor/Flush BR24L70FG BR24L70FGP0 5 125 MLO 2 4 Indoor/Surface BR241_125S BR241_125SP 6 NEW a14-1/0 Outdoor BR24L125R BR24L125RPO 6RNEW Indoor/Flush BR24L125F BR24L125FP 6 NEW 125 MLO 4 8 Indoor/Surface BR48L125S BR48L125SP 7 z14-1/0 Indoor/Surface BR48L125SG BR48L125SGPO 7 Outdoor BR48L125R BR48L125RPo 7R Indoor/Flush BR481-1251' BR48L125FP 7 Indoor/Flush — BR481.125FDPO 7 Indoor/Flush BR48L125FG BR48L125FGPO 7 125 MLO 6 12 Indoor/Surface BR612L125S BR612L125SP 7 f14-1 Indoor/Surface BR612L125SG BR6121.125SGP0 7 Indoor/Surface BR612LI25SD BR612L125SDP0 7 Indoor/Surface BR612L125SDG BR612L125SDGPw 7 Outdoor BR612L125SR BR612L125RP4) 7R Indoor/Flush BR612L125SF BR612L125FP 7 Indoor/Flush BR612L125SFG BR612L125FGP0 7 Indoor/Flush BR612L125SFD BR612L125FDPO 7 Indoor/Flush BR612L125SFDG BR612L125FDGPw 7 125 MLO 8 16 Indoor/Surface BR8161.125S BR816L125SP 7 A4-1 Indoor/Surface BR816L125SG BR8161_125SGPO 7 Indoor/Surface BR816L125SD BR8161.1250PO 7 Indoor/Surface — BR8161.C125SOW coPPER 7 Indoor/Surface BR816L125SDG BR816L125SDGPOO •7 Outdoor BR816L125R BR8161.125RPO 7R Indoor/Flush BR8161.1251' BR816L125FP 7 Indoor/Flush BR816L125FG BR816L125FGPo 7 Indoor/Flush BR816L125FD BR816L125FDPO 7 Indoor/Flush — BR816LC125FDPO4 coPPER 7 Indoor/Flush BR8161.125FDG BR816Ll25FDGP(m 1 0 Factory installed ground bar. O Hub is not included. Order Type OS hub separately. O Door included. 4 New copper bus offering. Loadcenters 13