04-8415 (SFD)s
4�. BUILDING 8C SAFETY DEPARTMENT
P.O.- Box 1504
-(760)7774012
C� OFTt�9 ' 78-495 CALLE TAMPICO
FAX (760).777-701' 1
IN ALIFORNIA 92253 INSPECTION REQUESTS:(76.0) 777-7153
BUILDING PERMIT
MAY 12 2005 ri 4
A plicc�lpPi ,A]aME b'er . . 104-00008415 Date 5/04/05
P 57815 RESIDENZA CT
APN: 764010-011-82 -30092 -
Application description.. DWELLING SINGLE FAMILY DETACHED
Property Zoning . LOW DENSITY RESIDENTIAL
Application'valuat on . . . 190928
Owner Contractor
K. HOVNANIAN FORECAST HOMES K.. HOVNANIAN FORECAST HOMES
4:240. -�E.. JURUPA ST., STE. - 402 4240 E.: JURUPA STREET
CHINO; CA 917.10: ONTARIO;.. CA .91761
:. (909).937-3270
WCC: ZUR.ICH.INS
WC: WC343666302 10/31/05
CSLB: 700788 10/31/05
CCC: B
i
.P .0. BOX 1504 C&lf 4
78-495 CALLE TAMPICO
LA QUINTA, CALIFORNIA 92253
BUILDING & SAFETY DEPARTMENT
VOICE (760) 777-7012
FAX (760) 777-7011
INSPECTIONS (760) 777-7153
Application Number: 04- $ u 15 Date:.5 / •4� `
Applicant. Archlte t or
f/1
Applicant's Mailing Address: rchitect or
Address:
No.: /q'3�
BUILDING PERMIT DECLARATIONS
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals
Cede, and my Licensej�,in full force and effect.
//License Class icense No. -%0,eP' 7�
ate L c1 rzontractor
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for thelollowing reason (Sec. 7031.5, Business and Professions Code: Any
city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed
statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business
and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects
the applicant to a civil penalty of not more than five hundred dollars ($500).):
U I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work
himself or herself or through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors'
State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to.
the Contractors' State License Law.).
U I am exempt under Sec. , BA P.C. for this reason
Date
WORKERS' COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My orkers' compensation m nce carie a d ' y n e r
arrier ��t Imo( olicy Number C/'m?jh� C�
I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers'
compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall
forthwith comply with those provision B
WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND
CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN
SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.).
Lender's Name /A
Lenders Address A
APPLICANT ACKNOWLEDGEMENT '
IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application.
1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit
issued as a result of this application, the owner, and the applicant, each agrees to, and shall, defend, indemnify and hold harmless the City of La Quinta, its
officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit.
2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or
cessation of work for 180 days will subject permit to cancellation.
I certify that I have read this application and state that the above i formation is correct. I agree to comply with all city and county ordinances and state laws relating to building
construction, and hereby authorize representatives of this cou to enter upon the abo -mentioned property for inspection purposes.
ate OV—')-eig�n.tue
(Applicant or Agent):
i
_ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Application Number . . 04-00008415
i-
---------------------------------------------------------------------------
Structure Information
Construction Type . .
. . . TYPE V -.NON RATED
Occupancy Type
. . .
. . DWELLG/LODGING/LONG <=10
Flood Zone ;.
NON -AO FLOOD ZONE
Other struct info
. .
. . . CODE EDITION 2001 CBC
FIRE SPRINKLERS NO
GARAGE SQ FTG
687.00
PATIO SQ FTG
858.00
NUMBER OF UNITS
1.00
------------------------------------------------------------------------------
1ST FLOOR SQUARE FOOTAGE
2903.00
Permit . . . .
BUILDING PERMIT
Additional desc
Permit Fee
958.00 Plan Check Fee
622.70
Issue Date . .
. .
Valuation . . . .
190928
Expiration Date
10/31/05'
Qty Unit
Charge
Per
Extension
BASE FEE
639.50
91.00
-----------------------------------------------------------------------------
3.5000
THOU BLDG 100,001-500,000
318.50
Permit
MECHANICAL
Additional desc
Permit Fee
90.00 Plan Check Fee
22.50
Issue Date . .
. .
Valuation
0
Expiration Date
10%31/05
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
2.00
9.0000
EA MECH FURNACE <=100K
18.00
2.00
9.0000
EA MECH B/C <=3HP/100K BTU
18.00
5.00
6.5000
EA MECH VENT FAN
32.50
1.00
----------------------------
6.5000
EA MECH EXHAUST HOOD
--------------------------=---------------------
6.50
'Permit . .
. .
ELEC-NEW RESIDENTIAL
Additional desc
Permit Fee
130.35 Plan Check Fee
32.59
Issue Date . .
. .
; Valuation . . . .
0
Expiration Date
10/31/05
Qty Unit
Charge
Per
Extension
BASE FEE
15.00
2903.00
.0350
ELEC NEW RES - 1 OR 2 FAMILY
101.61
687.00•
---------------------------------------------------
.0200
ELEC GARAGE OR NON-RESIDENTIAL
-----=-------------------
13.74
•Permit . . . .
. .
PLUMBING
Additional desc
Permit Fee
173.25 Plan Check Fee
43.31
Issue Date . .
. .
Valuation . .
0
Expiration Date
.10/31/05
Qty Unit
Charge.
Per-
Extension
BASE FEE
15.00
17.00
6.0000
EA PLB FIXTURE
102.00
1.00 15.0000
EA PLB BUILDING SEWER.
15.00
Application Number ...
---------------------------------------------------
. . . 04-00008415
Permit
--------------------
PLUMBING
-----
Qty Unit Charge
Per
Extension
1.00 7.5000
EA PLB WATER HEATER/VENT
7.50
1.00 3.0000
EA PLB WATER INST/ALT/REP
3.00
1.00 9'.0000
EA PLB LAWN SPRINKLER SYSTEM
9.00
9.00 .7500
EA PLB GAS PIPE >=5
6.75
1.00 15.0000
----------------------------------------------------------------------------
EA PLB GAS METER
15.00
Permit . . . . . .
GRADING PERMIT
Additional desc
Permit Fee
15.00 Plan Check Fee
.00
Issue Date . . . .
Valuation
0
Expiration Date
10/31/05
Qty Unit Charge
.Per
Extension
BASE FEE
15.00
----------------------------------------------------------------------------
Special Notes and Comments
SFD - LOT 82, PLAN 2C/858.SF
PATIO(2903
SF). PERMIT DOES NOT
INCLUDE.POOL; SPA,
BLOCK WALLS OR DRIVEWAY APPROACH
-------------------------------------------------------------------------------
Other Fees . . .
. . ART IN PUBLIC PLACES -RES
.0,0
DIF COMMUNITY -CENTERS -RES
97.00
DIF CIVIC CENTER - RES
366.00
ENERGY REVIEW FEE
62.27
DIF FIRE PROTECTION -RES_
97.00
GRADING PLAN CHECK FEE
00
DIF LIBRARIES - RES
225.00
DIF PARK MAINT FAC - RES
5.00
DIF, PARKS/REC'- RES,
502.00
STRONG MOTION (SMI) - RES
.19..09
;DIF STREET MAINT.FAC-RES
15.00
DIF TRANSPORTATION - RES
1098.00
Fee summary Charged
Paid_ Credited
Due
Permit Fee Total
1366.60 .00 .00
1366.60
Plan Check Total
721.10' .00 .00
721.10
Other Fee Total
2486.36 .00 .00
2486.36
Grand Total.
4574.06 .00 .00
4574.06
SOUTHWEST INSPECTION AND -TESTING INC.
10826 S. Norwalk #A ,
Santa Fe SF:,r,ings, CA 90670
062-"941 -2990 714-526-8441 Fax -562-946-0026
FIELD DATA ON TEST SPECIMENS,
--- ASTM C31, C138, C1434 C1721 C173, C231, ' C1064 ---
CONCRETE :. X GROUT : - MORTAR: SHOTCRETE : 0 N I TE :
ADDRESSn57w615- RESIDENZA C LA G?UINTA JOB #: 50132 DATE: 07J12J2005
JOB NAME: PIAZZA SERENA/LA QUINTA 97 PERMIT #: 04--8415 ISSUED BY:
ARCHITECT: K. T. G. Y, GROUP ARCH INC. ENGINEER:
CONTRACTOR: K. HOVNANIAN FORECAST . SUB CONTRACTOR:, CAMPBELL CONCRETE OF CALIF.
LOCATION IN STRUCTURE: LOT 4 ,82 / GARAGE FOOTING
CONCRETE SUPPLIER: SUPERIOR.RDY MX PLANT: MIX #: D815P
TYPE OF CEMENT : ADMIXTURE: TICKET #: 7432367
.SLUMP : 4 1/2'' WATER,ADDED 0 GAL AIR TEMP: 70 F.
CONCRETE TEMP: 66 F MIXING TIME: .45 MIN TIME CAST: 6:30
- r •
DATE CAST: 6/4/2005 RECEIVED AT LAB: 6/6/2005
SPECIMENS MADE BY: PHIL LIMON JR. SPECIFIED PSI : '2500 '
FIELD IDENTIFICATION1 A I B I C 1 D I E
-------------
LAB-IDENTIFICATION : .508922 : 508722 : 508922
r
'AGE DAYS . 14 A 288
DATE TEST : 6418/2005 : 7/2/2005 : 7/2/2005
.SIZE -IN. , 6002X12 , 6.000X12 6.00+X12 ,
AREA-SQ.IN. 28.,M : 26.27" . 2031
CRUSH LOAD --- LBS : 65200 : 97700 : 98600 . .
COMP--STR.-PSI. . 2300 , 3455 . 3480
I H/D ' ,
CORR FACTOR .,
CORR. STR. -PSI
TIME TESTED
BREAK TYPE
C.T.M. USED . . ,
REMARKS:
ASTM 0399 C174, C192; C4701 C617, C42
COMPLIES: X DOES NOT COMPLY: _
THIS REPORT SHALL NOT -BE REPRODUCED, EXCEPT IN FULL WITHOUT THE APROVAL OF SITI
RESPECTFULLY SUBMITTED r
SOUTHWE T INSPECTION AND TESTING
SAMPLES CAST BY OTHERS:
XRENAN R. C
L_AB. MAN r<
ASTM C39 BREAKS A= cone B= cone and split C= cone D=shear E=columnar