Loading...
AR-14-64178-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: Property Address: APN: Application Description Property Zoning: Application Valuation: t AR -14-641 57325 PENINSULA LN c&t,, D VOICE (760) 777-7125 FAX (760) 777-7011 COMMUNITY DEVELOPMENT DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 7/7/2014 Owner: KIM & GREG BAY 762150010 NOOK ENLARGEMENT 207 SQ. FT. $49,999.90 Applicant: SUUTHERN HILLS DEVELOPMENT 78150 CALLE TAMPICO STE 101 LA QUINTA, CA 92253 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 {commencing with Section 7000) of Division 3 of the Business and Professions Code, and my License is in full force and effect. License Class: License -No.: Date: .f — 111 Contractor: OWNER-BUI DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). (_) I am exempt under Sec. . B.&P.C. for this reason Date: 2 7 " i / Owner: i n W -14J CONSTRUCTI N IENDING AGENCY I hereby affirm under penalty of perjury t at there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's 52325 PENNINSULA LN LA QUINTA, CA 92253 Contractor: SOUTHERN HILLS DEVELOPMENT 78150 CALLE TAMPICO STE 101 LA QUINTA, CA 92253 Llc. No.: WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: _ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier:_ Policy Number: _ _ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. / Date: 7 7-/ 7 Applicant: WARNING: FAILURE TO SECURE WORKER OMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT:Application is hereby made to the Building Official for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application , the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents, and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter up the above- mentioned property for inspection purposes. n Date: 1— J— 1-7 Signature (Applicant or Agent FINANCIAL INFORMATION DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, EA ADDITIONAL 500 SF 101-0000-42400 0 $61.49 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE ADDITION, FIRST 100 SF 101-0000-42400 0 $120.12 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY :I Total Paid forADDITION: $181.61 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE BSAS SB1473 FEE 101-0000-20306 0 $2.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forBUILDING STANDARDS ADMINISTRATION BSA $2.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE RESIDENTIAL, FIRST 1,000SF 101-0000-42403 0 $143.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forELECTRICAL - NEW CONSTRUCTION: $143.00 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE HOURLY PLAN CHECK 101-0000-42600 $157.50 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forHOURLY PLAN CHECK $157.50 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE APPLIANCE REPAIR/ALTERATION 101-0000-42402 0 $11.92 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forMECHANICAL: $11.92 $0.00 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PLAN CHECK, ELECTRICAL 101-0000-42600 $47.19 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PLAN CHECK, ELECTRICAL: $47.19 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PLAN CHECK, MECHANICAL 101-0000-42600 $4.77 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid for PLAN CHECK, MECHANICAL: $4.77 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PLAN CHECK, ROOM ADDITION 101-0000-42600 $168.74 PAID BY •. METHOD RECEIPT # - CHECK # CLTD BY DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE PLAN CHECK, ROOM ADDITION 101-0000-42600 $17.16 PAID BY METHOD RECEIPT # CHECK.# CLTD BY Total Paid for PLAN CHECK, ROOM ADDITION: $185.90 DESCRIPTION ACCOUNT QTY AMOUNT PAID PAID DATE SMI - RESIDENTIAL 101-0000-20308 0 $5.00 $0.00 PAID BY METHOD RECEIPT # CHECK # CLTD BY Total Paid forSTRONG MOTION INSTRUMENTATION SMI: $5.00 $0.00 TOTALS: $738.89 00 1 Bin #QtYof. 8uffdigg III Safety Aivir n 'Perinit # P.O. Box €504,:78-495 Calk Tampfcd fa Quanta, CA 92253 -x(760) 777 7012 g PennftA pliption and Traddng Sheet Ptnject Addtrss: e01 �nS v ani Ownees Name A. P. Number. ' , � ©/ a Add t+ s 5-73 Z �n �s L ' Legal Description /� . % y _Z152,21 City, ST, Zip: Contractor: {��i(/� ►Nil /el Telephone: Cog— �S � 2 - 2 2 Address: % �(�,• f �� vn i G-dit to Project Desaition: P ry CSG o l /L n-� City, STZip: p: l�/ V I� /1 . Cin � �,� • � � ,rPS) CC_ Telephone: , -77(- i'l.S.�Cc D . en' A <r I(,- State Lit # : © City/Lie, f PG 7[-a Address: / 11`ea lk, City., ST, Zip: Telephone: (47ol ConstuctionTYK. , Oocupancq; State Lic. #: 3 . L Project we (emit one}:14ow AWd n) Alter Repair Demo Name of Costal t Person: Sq. Ft.: 2 0 7 1 0 Stories: if Units: Telephone # of Contact Person: 74 rJ - o Estimated Value of Pm3ect APPLICANT, DO NOT VttiiiTE BELOW Till& UNE - N Sabmittal Req'd 'd 'iRA�G PERMIi'FS�S Plea Seta Plan Check submitted " t Term r - AmoctnC S' Strgdaral CAlcs. Reviewed, ready for wrrations Plase C3csckDeposit.• _ Truss Cates. Called Contact Person Plan CheekBslaance Title 24 Coks, Plans pickidup ConstrnctioiY Flood plain pian Plans resubmitted.'. 14 Mechadieal ,Grading plan Z"; Revicxt, ready for coetmetia issue C cf F�ectrieal Subcoutactorlast Caped Contact Person Piutn • C Great Deed Plans picked up H.O.A. Appro'd Pians resubmitted Gra ag q RH iliOtiS)P:- Review; ready for correctionslisaac De eiopesr impact F"44, Ptanning Approval• Called Contact Person • ,p, " Pub. Wks, Appr - Date of permit issue Scboot Fees Permit Fees e �l� a, rv, Coachella -Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 (760) 398-5909 — Fax (760) 398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT LEVEL ONE AMOUNT : LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/IND. AMOUNT: DATE: RECEIPT: CHECK#: INITIALS CERTIFICATE OF COMPLIANCE (California Education Code 17620) Project Name: Greg &Kim Bay Owner's Name: Project Address: 57-325 Peninsula Lane, La Quinta, CA 92254 Project Description: Room Addition Date: July 1, 2014 Phone No. 760-485-0497 APN: 762-150-010 Tract #: Lot #'s: Type of Development: Residential XX Commercial Total Square Feet of Building Area: 207 Sq. Ft. Industrial Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: — I L/ Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project 17620 65995 Approval Number of Sq.Ft. 207 Sq. Ft. Amount per Sq.Ft. EXEMPT Amount Collected 0.00 Building Permit Application Completed: Yes/No By: Elsa F. Esqueda, Director of Facilities and Maintenance Certificate issued by: Leticia Torres, Facilities Analyst Agreement Existing Not Subject to Fee Prior to 1/1/87 Requirement Note: Pursuant to AB -181 Any Room Addition of 500 Sq. Ft. !or _Less _is_Exempt from Developer Fees. Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requirethat t . District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment, of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will be granted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. MV:c/mydocs/devl'ees/certificate of compliance form updated 3-2007 11/2010 JOVENENGINE ERING S t r u c t u r, a 1 E n g I n e e r I n g, P.O. Box 5098 Lo Quinta, CA. 92248-5098 Phone(760)408-6441 June 12, 2014 City of La Quinta Building & Safety Department 78-495 Calle Tampico La Quinta, CA 92253-1504 Project: Bay Residence Remodel 57325 Peninsula Lane La Quinta, CA Subject: . Roof Truss Calculations Dear Sirs; Job No. 14-731 We have been provided with Wood Truss Calculations prepared by Imperial Truss and Lumber to be used on the above referenced project. We have reviewed layout and calculations and find them to be in general agreement with the design intent for this project. If you have further questions, please call our office anytime. Sincerely, JOVEN ENGINEERING Jos h R. Venuti, P.E. Proj ct Engineer I CAIYOFLAC UINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRU TION DATE (/ �' Bir CACAJOVENVOB5\2014\731 BAY REMODEL L.O\TRUSS REVIEW 731.DOCX.1/10/05 BUILDING-- ENERG=Y' AhIALYSI=S- REPORT*. PROJECT: Bay Residence 57325 Peninsula La La Quinta,. CA 92253 Project Designer: South West Concept Inc 78-11:5,:Calle..:Estado-.SUit 1:05 La Quinta, CA 92253 760-564-4707 Report Prepared by: Gary Faucette A.V. Energy & Associates 45263 7th Street East #43 `Lancaster, `CA 93535 100M. ab ar, � • JUN 12 2014 CITY OF LA QUINTA COMMUNITY DEVELOPMENT Job Number: -=AD7791 Date: 6/10/2014 CITY OF Imo` QUINTA BUILDING & SAFETY DEPT. APPROV D The EnergyPro computer program has been used to perform the calculations summarized in this c4 p1T n�M, o ft) T i r, �n has a proval and is authorized by the California Energy Commission for use with both the Residential ad Nonresic�entiaf2068 Building E rgy Efficiency tandards. This program developed by EnergySoft, LLC � DATE er s BY r ITABLE Of CONTENTS I --Cover-:Fage 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form MF -1 R Mandatory Measures Summary 8 HVAC .S,ystem-Heatin ' and. Cooling: -Loads-Summary. 1.1... 9� Room Load Summary 12 Room Heating Peak Loads 13 Room Cooling Peak Loads 14 .Form -ECONA .-E ne rgy..U,se.-a-nd .-Qost.,S.u.m ma ry 15 Form ECON-2 Energy Upgrade Recommendations 16 Form UTILAR Utility Incentive Worksheet 17 CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION DATE - BY. I EnergyPro 5.1 by EnergySoft Job Number: ID: AD7791 - - -- - User Number: 6055 1 "PERFORMANCE CERTIFICATE": Resident -rat Part" l -of 5 CF -1-11' Project Name Bay Residence Building Type m Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 Project Address 57325 Peninsula La La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 207 Addition 207 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Area Special Construction Type Cavity Features see Part 2 of 5 Status Slab_ Unheated. Slab -on -Grade- None. 207 Perim. = 67' New Wall Wood Framed R-21 377 New Roof Wood Framed Attic R-38 207 Radiant Barrier New FENESTRATION U- Exterior Orientation Area ff2 Factor SHGC Overhang Sidefins Shades Status Front (E) 4.5 0.340 0.33 10.0 none Roll -down Blind or Slats New Left (S) 70.0 0.340 0.33 10.0 none Roll -down Blind or Slats New Rear (1M 48.0 0.340 0.33 10.0 none Roll -down Blind or Slats New HVAC SYSTEMS Ot . Heating Min. Eff Cooling Min. Eff Thermostat Status 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Duct Location Heating Coolie Duct Location R -Value Status HVACS Ducted Ducted Attic, Ceiling Ins, vented 8.0 Altered WATER HEATING 1C -11Y C,I1Y O` LA QU,N-P Ot . Type Gallons Min:. Eff Distribution _ _ __St�atIs. M SUILUIIVucxuht�Y..= 1 Ljr- t. f OR CONS I RUG i ION I EnergyPro 5.1 by Ener Soft User Number. 6055 RunCode: 2014-06-10T14:25: laDATE 1DL AD779a BY P_ag " 3 of 17 I J PERFORMANCE CERTIFICATE: Residential Part 2 of 5) CF -1 R TBuilding Project Name® Bay Residence Type Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. HERS REQUIRED VERIFICATION Items in this section require field testing and/or verification by a certified HERS Rater. The inspector must receive a com letedC,F-4.R.formf.or.each,of,the.measureslisted..belowiorlinal.to.be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. HVACS includes a factory sealed air handler unit tested by the manufacturer and certified to the Commission to have achieved a 2 percent or less leakage rate. HERS field verification of the AHU model number is required. Duct Leakage cannot exceed 6%. CITY OF LA QiJIiVT & SAFETY DEPT. w' iry r� q A �-- FOR CONSTRUCTION Ener Pro 5.1 by Ener Soft User Number: 6055 RunCode: 2014-06-10TM:25:18 ID: AD f— --—.—P_a e 4 of 17 PERFORMANCE CERTIFICATE: Residential - (Part 3 of 5) CF -1 R Project Name Building Type m Single Family m Addition Alone Date Bay Residence 1 ❑ Multi Family ❑ Existing+ Addition/Afteration 1611012014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2 r Space Heating 14.77 16.11 -1.34 Space Cooling 115.61 106.02 9.59 Fans 30.36 28.46 1.90 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 160.74 150.60 10.14 Percent Better Than Standard: 6.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E)90 deg Ext. Walls/Roof, Wall Area Area Number of Dwelling Units: 0.04 (E) 90 5 Fuel Available at Site: Natural Gas (S) 235 70 Raised Floor Area: 0 (tM 174 46 Slab on Grade Area: 207 (N) 0 0 Average Ceiling Height: 12.0 Root 207 0 Fenestration Average U -Factor: 0.34 TOTAL: 123 Average SHGC: 0.33 Fenestration/CFA Ratio: 59.2% REMARKS STATEMENT OF COMPLIANCE A.V. EIvTA.cx AssocI,►M This certificate of compliance lists the building features and specifications needed California Title 24 to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Gary Faucette Efficiency Standards of the California Code of Regulations. energy consuffent The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company A. V. Energy & Associates Address 45263 71h Street East #43 Name Gary Faucette Ci /State/Z'i Lancaster, CA 93535 Phone 661-723-6694 Si ned "Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Company South West Concept Inc Address 78-115 Celle Estado Suit 105 Name Steve Nieto City/Stateop La Quinta, CA 92253 Phone 760-564-4707 Signed license # Date A I Y OF LA 01 JINITA Ene ro5.16 Ene Soft User Number. 6055 RunCode:20140&-10T14k25: I At37791 n T- _ a e l.ot 17 — -- -- .. — I L.JLi APPROVED FOR CONSTRUCTION TE BY �- CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Bay Residence Building Type m Single Family 1 ❑ Multi Family m Addition Alone O Existing+ Addition/Alteration Date 1611012014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Slab 207 0.730 None 0 180 New 4.4.7-A I 1st fl addition Wall 86 0.069 R-21 90 90 New 4.3.1-A6 1st fl addition Wall 165 0.069 R-21 180 90 New 4.3.1-A6 1st fl addition Wall 126 0.069 R-21 270 90 New 4.3.1-A6 1st f/ addition Roof 207 0.025 R-38 90 30 New 4.2.1-A21 1st fl addition FENESTRATION SURFACE DETAILS ID T e Area U -Factor SHGC Azm Status Glazin Type Location/Comments 1 Window 4.5 0.340 NFRC 0.33 NFRC 90 New Andersen Permashield 1 st fl addition 2 Window 70.0 0.340 NFRC 0.33 NFRC 180 New Andersen Permashield ist fl addition 3 Window 48.0 0.340 NFRC 0.33 NFRC 270 New Andersen Permashield 1st ft addition (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-B = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Len H t LExt RExt Left Fin Ri ht Fin Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 2 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 3 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 f f IKlr-% f O A r- i'sir-' r �E � . APPROVED FOR CONSTRUCTION Ener Pro 5.1 by Ener Soft User Number: 6055 RunCode: 2014-06-10T14:25: 8 ID: AD7791 Paoi 6 07 17 LATE BY � — CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Bay Residence Building Type © Single Family m Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existing Altered Removed Volume Year Built HVACS 1st f/ addition 207 2,484 Totals 207 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVACS 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION System Name Heating Duct Ducts Cooling Duct Location R -Value Tested? Status HVACS Ducted Ducted Attic, Ceiling Ins, vented 8.0 m Altered WATER HEATING SYSTEMS S stem Name Q Type Distribution Rated Input Btuh Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 m <.EI System Name Pipe Length Pipe I Diameter Insul. Thick. Qty. FHP Plenum Outside Buried ❑ _ ❑ N B IL I U& SAFE f, UEPT. ❑M �la� r1\ /` ❑ r li Y fl e t r ♦-tl-nw — e Y f'lU I I Ener Pro 5.1 by Ener Soft User Number: 6055 RunCode: 2014-06-10T14:24:18 ID: AD7791 Pa ,e 7 of 17 IDATE BY I MANDATORY MEASURES SUMMARY: Residential (Pape 1 of 3) MF -1 R Bay Residence 6/10/2014 NOTE: Low-rise residential buildings subject to the Standards must comply with all applicable mandatory measures listed, regardless of the compliance approach used. More stringent energy measures listed on the Certificate of Compliance (CF -1 R, CF -1 R -ADD, or CF - 1 R -ALT Form) shall supersede the items marked with an asterisk (*) below. This Mandatory Measures Summary shall be incorporated into the permit documents, and the applicable features shall be considered by all parties as minimum component performance specifications whether they are shown elsewhere in the documents or in this summary. Submit all applicable sections of the MF -1 R Form with plans. Buildina Envelope Measures: 116(a)l: Doors and windows between conditioned and unconditioned spaces are manufactured to limit air leakage. §116(a)4: Fenestration products (except field -fabricated windows) have a label listing the certified U -Factor, certified Solar Heat Gain Coefficient SHGC , and infiltration that meets the requirements of 10-111 (a). 117: Exterior doors and windows are weather-stripped; all joints and penetrations are caulked and sealed. 118(a): Insulationspecified or installed meets Standards for Insulating Material. Indicate type and include on CF -6R Form. §118(i): The thermal emittance and solar reflectance values of the cool roofing material meets the requirements of §118(i) when the installation of a Cool Roof is specified on the CF -1 R Form. *&150(a): Minimum R-19 insulation in wood -frame ceilina or eauivalent LI -factor. §150(b): Loose fill insulation shall conform with manufacturer's installed design labeled R -Value. *§1 50 c : Minimum R-13 insulation in wood -frame wall orequivalent Ll -factor. *§1 50 d : Minimum R-13 insulation in raised wood -frame floor or equivalent LI -factor. 6150(f): Air retardina wrap is tested. labeled. and installed accordina to ASTM E1677-95(2000) when specified on the CF -1 R Form. 150 : Mandatory Vapor barrier installed in Climate Zones 14 or 16. §150(1): Water absorption rate for slab edge insulation material alone without facings is no greater than 0.3%; water vapor permeance rate is no greater than 2.0perm/inch and shall be protected from physical damage and UV light deterioration. Fireplaces. Decorative Gas Appliances and Gas Lou Measures: 150 e 1 A:'Masonry or facto -built fireplaces have a closable metal or glass door covering the entire opening of the firebox. §150(e)1 B: Masonry or factory -built fireplaces have a combustion outside air intake, which is at least six square inches in area and is equipped with a with a readily accessible, operable, and ti ht -f itting damper and or a combustion -air control device. §150(e)2: Continuous burning pilot lights and the use of indoor air for cooling a firebox jacket, when that indoor air is vented to the outside of the building, are prohibited. Space Conditioning, Water Heating and Plumbing System Measures: §110-§113: HVAC equipment, water heaters, showerheads, faucets and all other regulated appliances are certified by the Energy Commission. §113(c)5: Water heating recirculation loops serving multiple dwelling units and High -Rise residential occupancies meet the air release valve, backflow prevention, pump isolation valve, and recirculation loop connection requirements of §113(c)5. §115: Continuously burning pilot lights are prohibited for natural gas: fan -type central furnaces, household cooking appliances (appliances with an electrical supply voltage connection with pilot lights that consume less than 150 Btu/hr are exempt), and pool and 6150(h): Heatina and/or coolina loads are calculated in accordance with ASHRAE, SMACNA or ACCA. I §1500): Heating systems are equipped with thermostats that meet the setback requirements of Section 112(c). §1500)1A: Storage gas water heaters rated with an Energy Factor no greater than the federal minimal standard are externally wrapped with insulation having an installed thermal resistance of R-12 or greater. §1500)1 B: Unfired storage tanks, such as storage tanks or backup tanks for solar water -heating system, or other indirect hot water tanks have R-12 external insulation or R-16 internal insulation where the internal insulation R -value is indicated on the exterior of the tank. §1500)2: First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes are insulated per Standards Table 150-B. §1500)2: Cooling system piping (suction, chilled water, or brine lines),and piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A. §1500)2: Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements of Standards Table 150(j)3A: Insulation is protected from damage, including that due to sunlight, moisture 1500)3A: Insulation for chilled water piping and refrigerant suction lines includes a vat onditioned space. 150(j)4: Solar water -heating systems and/or collectors are certified by the Solar Ratinc =nergyPro 5.1 by EnergySoft User Number: 6055 RunCode: 2014-06-10714:25:18 equjptgie�J �tt,m,aintenance, and wind. or retaGd'4rif o(�Wdncl'os"b I enfi�e,(y",,, ihJ I A 01 1111hir_ A cnrrrni nrn-r and CertificationNC—ororation:T FOR CONSTRUCTION ID: AD7791 Page 8 0 DATE By 17 MANDATORY MEASURES SUMMARY: Residential (Page 2 of 3 WAR Project Name Date Bay Residence 1611012014 §150(m)1: All air -distribution system ducts and plenums installed, are sealed and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R- 4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape or other duct -closure system that meets the applicable requirements of UL 181, UL 181 A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings reater than 1/4 inch, the combination of mastic and either mesh or tape shall be used §150(m)1: Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. §150(m)2D: Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands. §150(m)8: Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated §150(m)9: Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. 150 m 10: Flexible ducts cannot have porous inner cores. §150(o): All dwelling units shall meet the requirements of ANSI/ASHRAE Standard 62.2-2007 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings. Window operation is not a permissible method of providing the Whole Building Ventilation required in Section 4 of that Standard. I Pool and Spa Heating Svstems and Equipment Measures: §114(a): Any pool or spa heating system shall be certified to have: a thermal efficiency that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater; a permanent weatherproof plate or card with operating instructions; and shall not use electric resistance heating ora pilot light. §114(b)1: Any pool or spa heating equipment shall be installed with at least 36" of pipe between filter and heater, or dedicated suction and return lines, or built-up connections for future solar heating. 114(b)2: Outdoor pools ors as that have a heat pump or gas heater shall have a cover. §114(b)3: Pools shall have directional inlets that adequately mix the pool water, and a time switch that will allow all pumps to be set or proarammed to run only during off-peak electric demand periods. 150 : Residential pool systems or equipment meet the pump sizing, flow rate, piping, filters, and valve requirements of §150 . Residential Lighting Measures: §150(k)1: High efficacy luminaires or LED Light Engine with Integral Heat Sink has an efficacy that is no lower than the efficacies contained in Table 150-C and is not a low efficacv luminaire as specified by §150(k)2. 150(k)3: The wattage of permanently installed luminaires shall be determined asspecified by §130(d). §150(k)4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be electronic and shall have an output frequency no less than 20 kHz. §150(k)5: Permanently installed night lights and night lights integral to a permanently installed luminaire or exhaust fan shall contain only high efficacy lamps meeting the minimum efficacies contained in Table 150-C and shall not contain a line -voltage socket or line - voltage lamp holder; OR shall be rated to consume no more than five watts of power as determined by §130(d), and shall not contain a meaium screw -ease socKet. 4150(k)6: Lightinq inteqral to exhaust fans, in rooms other than kitchens, shall meet the applicable requirements of §150(k). §150(k)7: All switching devices and controls shall meet the requirements of §150(k)7. §150(k)8: A minimum of 50 percent of the total rated wattage of permanently installed lighting in kitchens shall be high efficacy. EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2 or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the 50% high efficacy requirement when: all low efficacy luminaires in the kitchen are controlled by a manual on occupant sensor, dimmer, energy management system (EMCS), or a multi -scene programmable control system; and all permanently installed luminaries in garages, laundry rooms, closets greater than 70 square feet, and utility rooms are high efficacy and controlled by a manual -on occupant sensor. §150(k)9: Permanently installed lighting that is internal to cabinets shall use no more than 20 watts of nower per ri ipar toot illuminated cabinet. ,r- I PiK=A L-A %-at it 10'4 1 1-% BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION 8� ID: AD 7791 Page DATE BY - 5. 1 Y 5.1 by EnergySoft User Number: 6055 RunCode: 2014-06-10T14:25:1 of 17 MANDATORY MEASURES SUMMARY: Residential (Page 3 of 3 MF -1 R Project Name Date Bay Residence 1611012014 §150(k)l0: Permanently installed luminaires in bathrooms, attached and detached garages, laundry rooms, closets and utility rooms shall be high efficacy. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by a manual -on occupant sensor certified to comply with the applicable requirements of §119. EXCEPTION 2: Permanently installed low efficacy luminaires in closets less than 70 square feet are not required to be controlled by a manual -on occupancy sensor. §150(k)l1: Permanently installed luminaires located in rooms or areas other than in kitchens, bathrooms, garages, laundry rooms, closets, and utility rooms shall be high efficacy luimnaires. EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed provided they are controlled by either a dimmer switch that complies with the applicable requirements of §119, or by a manual - on occupant sensor that complies with the applicable requirements of §119. EXCEPTION 2: Lighting in detached storage building less than 1000 square feet located on a residential site is not required to comply with §150 k 11. §150(k)l2: Luminaires recessed into insulated ceilings shall be listed for zero clearance insulation contact (IC) by Underwriters Laboratories or other nationally recognized testing/rating laboratory; and have a label that certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75 Pascals when tested in accordance with ASTM E283; and be sealed with a gasket or caulk between the luminaire housing and ceiling. §150(k)l3: Luminaires providing outdoor lighting, including lighting for private patios in low-rise residential buildings with four or more dwelling units, entrances, balconies, and porches, which are permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy. EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be allowed provided that they are controlled by a manual on/off switch, a motion sensor not having an override or bypass switch that disables the motion sensor, and one of the following controls: a photocontrol not having an override or bypass switch that disables the photocontrol; OR an astronomical time clock not having an override or bypass switch that disables the astronomical time clock; OR an energy management control system (EMCS) not having an override or bypass switch that allows the luminaire to be always on EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to §150(k)l3 may be controlled by a temporary override switch which bypasses the motion sensing function provided that the motion sensor is automatically reactivated within six hours. EXCEPTION 3: Permanently installed luminaires in or around swimming pool, water features, or other location subject to Article 680 of the California Electric Code need not be high efficacy luminaires. §150(k)14: Internally illuminated address signs shall comply with Section 148; OR not contain a screw -base socket, and consume no more than five watts of power as determined according to §130(d). §150(k)l5: Lighting for parking lots and carports with a total of for 8 or more vehicles per site shall comply with the applicable requirements in Sections 130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles shall comply with the applicable requirements of Sections 130, 131, 134, and 146. §150(k)16: Permanently installed lighting in the enclosed, non -dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires. EXCEPTION: Permanently installed low efficacy luminaires shall be allowed provided that they are controlled by an occupant sensors certified to comply with the applicable requirements of 119. CITY OF LA QUINTA BUILDING & SAFETY DEPT. APPROVED FOR CONSTRUCTION n AT EnergyPro 5.1 by EnergySoft User Number: 6055 RunCode: 2014-06-10714:25:18 In- An 7 1 Pagei0 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY Project Name Bay Residence Date 6/10/2014 System Name HVACS Floor Area 207 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING CFM Sensible 253 5,334 0 308 0 0 0 2,557 308 8,5071 PEAK COIL HTG. PEAK Heating System Latent CFM Sensible Output per System 74,000 981 112 5,586 Total Output Btuh 74,000 Output Btuh/s ft 357.5 275 Cooling System 0 Output per System 59,500 0 0 0 Total Output Btuh 59,500 9811 -2,557 Total Output Tons 5.0 275 Total Output Btuh/s ft 287.4 Total Output s ft/Ton 41.7 1 3,578 Air System CFM per System 1,916 HVAC EQUIPMENT SELECTION Airflow cfm 1,916 Carrier 38HDR060-3 w/ FX4C060 46,419 3,972 74,000 Airflow cfm/s ft 9.26 Airflow cfm/Ton 386.4 Outside Air % 0.0% Total Adjusted System Output (Adjusted for Peak Design conditions) TIME OF SYSTEM PEAK 1 46,4191 3,9721 Aug 3 PM 74,000 Jan 1 AM Outside Air cfm/s ft 0.00 Note: values above given at ARI conditions HEATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 26 OF 68 OF Outside Air 0 cfm Supply Fan 1,916 cfm 68 OF 69 OF 115 OF Heating Coil 115 OF ROOM 0 68 OF COOLING SYSTEM PSYCHROMETICS Airstream Temperatures at Time of Cooling Peak 112/78°F 75/62°F Outside Air 0 cfm 75 / 62 OF 76/62°F 55/54°F o �= Supply Fan Cooling Coil 1,916 cfm A/6 � �— 55 / °F CITY OF LA OUINT BUILDING 5°/SA'F�QQ*T °F �Ov { P 754 �� �.�r.,r�,rrTinl 4�TI��1 ��}I l VV51VA..Y� EnergyPro 5.1 by EnergySoft User Number: 6055 RunCode: 2014-06-10T14:25:18 DA I t _IDrAB9791— Pad, 11 of 17 ROOM LOAD SUMMARY Project Name Date Bay Residence 6/10/2014 System Name Floor Area HVACS 207 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK Zone Name Room Name M+,It.0 FM Sensible Latent CFM Sensible Latent CFM Sensible 1st fl addition 1st f/ addition 2531 5,3341 981 2531 5,3341 981 1121 5,586 PAGE TOTAL TOTAL* 253,5;334 1 ql tz L 12 ,,586 253 Y 5314 I ' J�81 I 1� 586 * Total includes ventilation load for zonal systems. I Ener Pro 5.1 by Ener Soft User Number. 6055 RunCode: 201406-10T14:25:18 I DATID;-AD.zz9J BY pa e_1.2 of 17 Y --- - - ROOM HEATING PEAK LOADS Project Name Bay Residence Date 6/10/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st fi addition Floor Area 207.0 ft' Indoor Dry Bulb Temperature 68 °F Time of Peak Jan 1 AM Outdoor Dry Bulb Temperature 26 OF Conduction Area perim = 67.0 X 376.7 X U -Value X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X -?5,6 App AT *F Btu/hr 42 = 2,054 42 = 1,092 42 = 1,749 42 = 217 = = = = = = = = = = = = = = = = = = = = = Page Total 5,113 !=6p X,j �42�� 473 U L d & SAFE I. Y DEPT. ���� Slab -On -Grade 0.7300 R-21 Wall 0.0690 Andersen Permashield 122.5 X 0.3400 R-38 Roof Attic 207.0 X X 0.0250 X X X X X X X X X X X X X X X X X X X X X X X X X X through an interior surface to X 207 X Area Ceiling Items shown with an asterisk (') denote conduction Infiltration:[ 1.00 X 1.064 Schedule Air Sensible Fraction another room 12.007: x.0 Height MCH BUILDING TOTAL HOURLY HEAT LOSS FOR ROOM M " , T , , r`T 15,586 ST Energ Pro 5.1 by Ener Soft User Number. 6055 RunCode: 2014-06-10T14:25:18, _ ID: AD7791 Pae 1 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Project Name Date Bay Residence 1 6/10/2014 ROOM INFORMATION DESIGN CONDITIONS Room Name 1st fl addition Outdoor Dry Bulb Temperature 112 OF Floor Area 207.0 ft2 Outdoor Wet Bulb Temperature 78 OF Indoor Dry Bulb Temperature 75 OF I Outdoor Daily Range: 34 OF Opaque Surfaces Orientation Area U-Factor CLTD' Btu/hr R-21 Wall (E) 85.5 X 0.0690 X 33.0 = 195 R-21 Wall (S) 165.2 X 0.0690 X 26.0 = 296 R-21 Wall (IM 126.0 X 0.0690 X 33.0 = 287 R-38 Roof Attic (E) 207.0 X 0.0250 X 56.0 = 290 X X = X X = X X = X X = X X = Page Total 1 1,068 Items shown with an asterisk (') denote conduction through an interior surface to another room. 1. Cooling Load Temperature Difference (CLTD) Shaded Unshaded Fenestration Orientation Area GLF Area GLF Btu/hr Front Window addition (E) 4.5 X 11.0 + 0.0 X 17.7 = 50 Left Window addition (S) 70.0 X 11.0 + 0.0 X 11.0 = 771 Rear Window addition W 48.0 X 11.0 + 0.0 X 17.7 = 528 X + X - X + X - X + X - X + X - X + X - X + X - Page Total 1 1,349 Internal Gain Btu/hr Occupants 4.0 Occupants X 230 Btuh/occ. = 920 Equipment 1.0 Dwelling Unit X 1,600 Btu = 1,600 Infiltration: 1.064 X 0.89 X 11.33 X 37 = 398 Air Sensible CFM ELA AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 5,334 Latent Gain Btu/hr Occupants 4.0 Occupants X r "-`2�` Bt�Uh oc� mi- QUI. 800 N V� V0� Infiltration: 4,771 X 0.89 X 11.33 X o.0037s = BUILDING & SAFETY DE 181 Air Sensible CFM ELA AW AP P RQV E D I I TOTAL HOURLY LATENT HEAT GAIN FOR ROOM M%-lint 981 M er P o 5.1 by Ener Soft User umber: 6055 C e 0 6- T I : AD BY of 17 t '' ENERGY USE AND COST SUMMARY ECON-1 Project Name Bay Residence Date 1 6/10/2014 Rate: Fuel Type: Electricity Energy - Use kWh STANDARD Peak Demand Cost kW $ Energy Use kWh PROPOSED Peak Demand kW MARGIN Energy Peak Cost Use Demand Cost $ kWh kW $ Jan 17 0 17 0 -1 0 Feb 12 0 11 0 1 0 Mar 15 0 10 0 5 0 Apr 40 1 26 1 14 0 May 108 1 93 1 15 0 Jun 241 1 221 1 20 0 Jul 297 1 283 1 14 0 Aug300 1 283 1 17 0 Sep 223 1 201 1 22 0 Oct 97 1 76 1 20 0 Nov 10 0 81 0 2 0 Dec 17 0 17 0 -1 0 Year 1,376 1 1,246 1 1 129 0 COz I lbs/yr I lbs/yr I I lbs/yr Rate: Fuel T e: Natural Gas Energy Use therms STANDARD Peak Demand Cost kBtu/hr $ Energy Use therms PROPOSED Peak Demand kBtu/hr MARGIN Energy Peak Cost Use Demand Cost $ therms kBtu/hr $ Jan 6 5 7 5 -1 0 Feb 3 5 4 5 0 0 Mar 1 5 2 4 0 0 Apr 0 0 0 2 0 -2 May 0 0 0 0 0 0 Jun 0 0 0 0 0 0 Jul 0 0 0 0 0 0 Aug0 0 0 0 0 0 Sep 0 0 01 0 0 0 Oct o 0 0 0 0 0 Nov 1 4 2 5 0 -1 Dec 6 6 7 6 0 0 Year 19 6 21 6 -2 0 COz I lbs/yr lbs/yr lbs/yr Annual Totals Energy Demand Cost Costs ft Virtual Rate Electricity 1,246 kWh 1 kW $ Wh Natural Gas 21 therms 6 kBtu/hr $ (Q! � eo Vs ) I NTA/ herm Total $ ,-9 ,$_ - FFY DEPT. E°mi RoQ: v �Avoide O�C D o bs/yr I FOR CONSTRUCTION EnergyPro 5.1 by EnergySoft User Number. 6055 RunCode: 2014-06-10T14:25:1 ID: AD 7791 Pae 15 of 17 DATE BY I Enerav Uoarade Recommendations ECQN=7 I Project Address 57325 Peninsula La Author Address 45263 7th Street East #43 La Quinta, CA 92253 Lancaster, CA 93535 Recommended Annual Est. Cost to Savings Improvements Description Savings Install Site TDV Annual Results Energy Cost End Use Existing Improved Savings Space Heating Space Cooling,0 Fans 0 Pumps Domestic Hot Water $0 Indoor Lighting $0 Outdoor Lighting Appliances/Plug Loads $0 Ancilla $0 Renewabies 0 TOTAL 0 CO2 (lbs/year -Existing Improved Savings Electricity Fossil Fuel 0 TOTAL 0 Fossil Fuel (therms) Climate Zone: 15 Electric Rate: Gas Rate: Floor Area: 20 Type: Single Family Average Demand(WV) 1.111 y TDV Energy (kBtur) � i C 1W OF LA QUI NTA /ft2-� � I f1 � Q� C � � � 'T' The estimated operating costs shown in this report are dependent upon many factors. The construction as�id�cbhlssint1tidl,Qa't�r $ f tfie ct b11� 1 i Equally important is the thermostat setting. How the thermostat is used, appliance use, and occupant interaction all i�flue�cg R�ffit�,�( e-fial ng :ost. The provided in this report are based on typical conditions; your actual usage will vary. APr <,J �/ �,J DATE BY 2013 CAHP UTILITY INCENTIVE WORKSHEET UTIL-1 R Project Name Date Bay Residence 6/10/2014 ANNUAL TDV ENERGY USE kBtu/s ft- r PERCENT BELOW Margin Standard TITLE 24 % Better' ENERGY COMPONENT Standard Pro osed Mar in Space Heating 14.77 16.11 -1.34 10.14 / 1 160.74 = 6.3 Space Cooling 115.61 106.02 9.59 coolin Standard Heat Rejection 0.00 0.00 0.00 9.59 / 1 115.61 Indoor Fans 30.36 28.46 1.90 Incentive Eligibility Yes No Domestic Hot Water 0.00 0.00 0.00 Owner Incentive (>=15%) ❑ m Pumps 0.00 0.00 0.00 NSHP Incentive (>=30%) ❑ m Conditioned Floor Area = 207.0 ft2 TOTALS: 160.74 150.60 10.14 Number of Bedrooms = 3 Energy Star V3 Target = 15 • ANNUAL SITE ENERGY USE Average 2pm - 5pm Standard Pro osed Margin Single Orientation Peak Demand kW 1.2 1.1 0.1 Standard Proposed Margin ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas kWh therms kWh therms kWh therms Space Heating 0.00 19.08 0.00 20.81 0.00 -1.73 Space Cooling 1,049.11 0.00 941.18 0.00 107.93 0.00 Heat Rejection 0.00 0.00 0.00 0.00 0.00 0.00 Indoor Fans 326.61 0.00 305.23 0.00 21.38 0.00 Domestic Hot Water 0.00 0.00 0.00 0.00 0.00 0.00 Pumps 00 0.00 0.00 E12 0.00 0.00 0.00 TOTALS: 1,375.72 19.08 42 20.81 129.30 -1.73 POTENTIAL OWNER INCENTIVE CALCULATION Potential incentives indicated % Better than Title -24* Incentive Savings on this report are available from ste 2� Rate � from Ste 3 subtotal Electricity (kWh) n/a n/a xi n/a only through the California Advanced Homes Program for $/kWh kWh new construction and are Electricity (kW) n/a �> n/a X NOT GUARANTEED. Projects $1WV kW must meet all other program Natural Gas � n/a x n/a requirements to qualify. Potential incentives are $nnerm therm subject to program limitations 2013 Code Preparation = Ma Pacific Gas and NSHP Tier II Electric Company SOU'IHFRN G1i-IFORNIA Tota) ED I S O N° Incentive rate is capped at the 45% level An F.OIYOS INTI R VATIOA4V.0 Company AW SD ff�\f A �j Sempra Energy ulauy` cal*fd n? phi LA CS U I NTA The 1 90% ad VCJ mi i`S iFETY DEPT. T11 M" Company FOR CONSTRUC TION A Sempra Energy mlury- EnergyPro 5.1.8.3 by EnergySoft User Number: 6055 RunCode: 2014-06-10T1,4:25:18 ID: AD7791 P ge 17 of 17 - .I Electronically Filed by Gary Faucette and Authenticated at CalCERTS.com - 6/12/2014 Electronically Signed at CalCERTS.com by Stephen Nieto (South West Concepts) 6/12/2014 PERFORMANCE CERTIFICATE: Residential Part 1 of 5 CF -1 R Project Name Bay Residence Building Type ® Single Family ® Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 Project Address 57325 Peninsula La La Quinta California Energy Climate Zone CA Climate Zone 15 Total Cond. Floor Area 207 Addition 207 # of Stories 1 FIELD INSPECTION ENERGY CHECKLIST ® Yes ❑ No HERS Measures -- If Yes, A CF -4R must be provided per Part 2 of 5 of this form. ❑ Yes ❑ No Special Features -- If Yes, see Part 2 of 5 of this form for details. INSULATION Construction Type Area Special Cavity Features see Part 2 of 5 Status Slab Unheated Slab -on -Grade None 207 Perim = 67' New Wall Wood Framed R-21 377 New Roof Wood Framed Attic R-38 207 Radiant Barrier New FENESTRATION U- Orientation Area Factor Exterior SHGC Overhang Sidefins Shades Status Front (E) 4.5 0.340 0.33 10.0 none Roll -down Blind or Slats New Left (S) 70.0 0.340. .0.33 _ _10.0 none __ Roll -down Blind or Slats New Rear (tM 48.0 0.340 0.33 10.0 none Roll -down Blind or Slats New Mq 2014s COMMUNITY HVAC SYSTEMS -0ty. Heating Min. Eff :Cooling Min. Eff Thermostat Status 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback Existing HVAC DISTRIBUTION Location Heating,Cooling Duct Duct Location R -Value Status HVACS Ducted Ducted Attic, Ceiling Ins, vented 8.0 Altered WATER HEATING Oty., Type. Gallons Min. Eff Distrib4ut ATY OF LA QMStaius N BUILDING & SAFETY DEPT. I APPROVED FOR CONSTRUCTION EnergyPro 5.1 by Energ Soft User Number. 6055 RunCode: 2014-06.10721:55:09 : AD7791 RV Page ,1 of 5 Reg: 214-N0042797A-000000000-0000 Registration Date/Time: 2014/06/12 1 Provider: CalCERTS, Inc J NT Electronically Filed by Gary Faucette and Authenticated at CalCERTS.com - 6/12/2014 Electronically Signed at CalCERTS.com by Stephen Nieto (South West Concepts) 6/12/2014 PERFORMANCE CERTIFICATE: Residential (Part 2 of 5) CF -1 R Project Name Bay Residence Building Type ® Single Family ® Addition Alone 1 ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 SPECIAL FEATURES INSPECTION CHECKLIST The enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The Roof R-38 Roof Attic includes credit for a Radiant Barrier that is Continuous meeting eligibility and installation criteria as specified in Residential Appendix RA4.2.2. j J0, 1 .. r HERS REQUIRED VERIFICATION ,, l Items in this section require field testing'and/or verification by a certified HERS Rater. The'inspector must receive a completed CF -4R form for each of the measures listed below for final to be given. Compliance credit for quality installation of insulation has been used. HERS field verification is required. HVACS includes a factory sealed air handler unit tested by the manufacturer and certified to the Commission to have achieved a 2 percent or less leakage rate. HERS field verification of the AHU model number is required. Duct Leakage cannot exceed 6%. CITY OF LA QUINTA BUILDING & SAFETY DEPT. r=-+ R E)V FOR CONSTRUCTION Ener Pro 5.1 by Ener Soft User Number., 6055 RunCode: 2014-06N10T21:55:00`7D.—AD•7-791— Reg: 214-N0042797A-000000000-0000 Registration Date/Time: 2014/06/12 12:59:06 HERS Provider: CalCERTS, Inc Electronically Filed by Gary Faucette and Authenticated at Ca10ERTS.com - 6/12/2014 Electronically Signed at CalCERTS.com by Stephen Nieto (South west Concepts) 6/12/2014 PERFORMANCE CERTIFICATE: Residential (Part 3 of 5) CF -1 R Project Name Building Type m Single Family m Addition Alone Date Bay Residence 1 ❑ Multi Family ❑ Existing+ Addition/Alteration 6/10/2014 ANNUAL ENERGY USE SUMMARY Standard Proposed Margin TDV kBtu/ft2- r Space Heating 14.77 16.11 -1.34 Space Cooling 115.61 106.02 9.59 Fans 30.36 28.46 1.90 Domestic Hot Water 0.00 0.00 0.00 Pumps 0.00 0.00 0.00 Totals 160.74 150.60 10.14 Percent Better Than Standard: 6.3% BUILDING COMPLIES - HERS VERIFICATION REQUIRED Fenestration Building Front Orientation: (E) 90 deg Ext. Walls/Roof Wall Area Area Number of Dwelling Units: 0.04 (E) 90 5 Fuel Available at Site: Natural Gas (S) 235 70 Raised Floor Area: 0 (W 174 48 Slab on Grade Area: 207 (N) 0 0 Average Ceiling Height: 12.0 Roof 207 0 Fenestration Average U -Factor: 0.34 TOTAL: 123 Average SHGC: 0.33 Fenestration/CFA Ratio: 59.2% REMARKS STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 the Administrative Regulations and Part 6 the Efficiency Standards of the California Code of Regulations. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Company A. V. Energy & Associates 6/10/2014 45263 7th Street East #43 Ga Faucette Address Name �' City/State/ZipCity/State/Zip Lancaster, CA 93535 Phone 661-723-6694 Signed Date The individual with overall design responsibility hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application, and recognizes that compliance using duct design, duct sealing, verification of refrigerant charge, insulation installation quality, and building envelope sealing require installer testing and certification and field verification by an approved HERS -rater. CITY OF (A QUINTA Designer or Owner (per Business & Professions Code) BUILDING & SAFETY DEPT. Company South west Concept Inc Address 78-115 Calle Estado Suit 105 Name Steve Nieto APPROVED Cit /State/Zi La Quinta, CA 92253 Phone 760-564-4707 riv City/State/Zip p rSigned License # ate I DATE BY Ener Pro 5.1 by Ene Soft User Number: 6055 RunCode: 2014-06-10T21:55:09L,_-JD;-A— - e 3 of 5 Reg: 214-N0042797A-000000000-0000 Registration Date/Time: 2014/06/12 12:59:06 HERS Provider: Ca10ERTS, Inc Electronically Filed by Gary Faucette and Authenticated at CalCERTS.com - 6/12/2014 Electronically Signed at CalCERTS.com by Stephen Nieto (South West Concepts) 6/12/2014 CERTIFICATE OF COMPLIANCE: Residential (Part 4 of 5) CF -1 R Project Name Bay Residence Building Type m Single Family 1 ❑ Multi Family ® Addition Alone ❑ Existing+ Addition/Alteration Date 1611012014 OPAQUE SURFACE DETAILS Surface U- Insulation Joint Appendix Type Area Factor Cavity Exterior Frame Interior Frame Azm Tilt I Status 4 Location/Comments Slab 207 0.730 None 0 180 New 4.4.7-A1 1st fl addition Wall 86 0.069 R-21 90 90 New 4.3.1-A6 1st f/ addition Wall 165 0.069 R-21 180 90 New 4.3.1-A6 1st f/ addition Wall 126 0.069 R-21 270 90 New 4.3.1-A6 1st f/ addition Roof 207 0.025 R-38 90 30 New 4.2.1-A21 1st f/ addition FENESTRATION SURFACE DETAILS ID Type Area U -Factor SHGC Azm Status Glazing Type Location/Comments 1 Window 4.5 0.340 NFRC 0.33 NFRC 90 New Andersen Permashield 1st fl addition 2 Window 70.0 0.340 NFRC 0.33 NFRC 180 New Andersen Permashield 1st fl addition 3 Window 46.0 0.340 NFRC 0.33 NFRC 270 New Andersen Permashield 1st fl addition {I t f (1) U -Factor Type: 116-A = Default Table from Standards, NFRC = Labeled Value 2 SHGC Type: 116-8 = Default Table from Standards, NFRC = Labeled Value EXTERIOR SHADING DETAILS Window ID Exterior Shade Type SHGC H t Wd Ove hang Len H t LExt RExt Left Fin Right Fin Dist Len H t Dist Len H t 1 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 2 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 3 Roll -down Blind or Slats 0.13 5.0 5.0 10.0 0.1 10.0 10.0 A A lip, rm- I I iM1 1 N'&SAE ETY D F PT F STRUCTION Ener Pro 5.1 by Ener Soft User Number: 6055 RunCode: 2014-06-10721:55:09 Tc ID: AD7791 PaqE 4 of 5 Reg: 214-N0042797A-000000000-0000 Registration Date/Time: 2014/06/12 12:59:06 HERS Provider: CalCERTS, Inc Electronically'Filed by Gary Faucette and Authenticated at Ca10ERTS.com - 6/12/2014 Electronically Signed at CalCERTS.com by Stephen Nieto (South West Concepts) 6/12/2014 CERTIFICATE OF COMPLIANCE: Residential (Part 5 of 5) CF -1 R Project Name Bay Residence Building Type ® Single Family m Addition Alone ❑ Multi Family ❑ Existing+ Addition/Alteration Date 6/10/2014 BUILDING ZONE INFORMATION System Name Zone Name Floor Area New Existina Altered I Removed Volume Year Built HVACS 1st fl addition 207 2484 Totals 2071 01 01 0 HVAC SYSTEMS System Name Qty. Heating Type Min. Eff. Cooling Type Min. Eff. Thermostat Type Status HVACS 1 Central Furnace 93% AFUE Split Air Conditioner 13.0 SEER Setback Existing . -- - -- - - r-7 _- .+ l , HVAC DISTRIBUTION, -- , I- System Name Heating —Duct'._ Ducts Cooling Duct Location R -Value Tested? Status HVACS Ducted Ducted Attic, Ceiling Ins, vented 8.0 m Altered 13 WATER HEATING SYSTEMS S stem Name Qty- Type Distribution Rated Input (Btu h) Tank Cap. al Energy Factor or RE Standby Loss or Pilot Ext. Tank Insul. R- Value Status CEC Standard MULTI -FAMILY WATER HEATING DETAILS HYDRONIC HEATING SYSTEM PIPING Control Hot Water Piping Length ft � 0 5 c Q — S stem NE7i e , Pipe `Len -th Pipe "Diameter Insul. Thick. Qty. HP Plenum Outside Buried ❑ Ui- LA C AMIT-A I ❑ 1 BUILDING A q,a r:Tv n -r 13�Y ❑FOR Gu--ib-1RUG--T101 Ener Pro 5.1 by Ener Soft User Number: 6055 RunCode: 2014-Ofr10T21:55:09OA,7791 Page 5 of 5 Reg: 214-N0042797A-000000000-0000 Registration Date/Time: 2014/06/12 12:59:06 HERS Provider: CalCERTS, Inc