Loading...
07-2400 (BLCK)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Td4t 4 4 Q" BUILDING & SAFETY DEPARTMENT- BUILDING EPARTMENTBUILDING PERMIT Application Number: t- .,07-000 02400- Owner: Property Address: 57175 PENINSULA LN TAYLOR APN: .762-150-023- - - 57-175 PENINSULA Application description: WALL/FENCE LA QUINTA,.. CA 922 Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 3880 Applicant: Architect or Engineer: Contractor: JACOBS HOMES INC, • P.O- BOX 692 _ LA QUINTA, CA 922 C�A(J� (760) 777-9921 Lic. No.: 799449 ' LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: B License No.: 799449 Date: L--� - .Contractor:! OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county.that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_) I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Coder The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale.: If, however, the building or improvement is sold within one year of completion, the owner -builder will have�the burden of proving that he or she did not build or - improve for the purpose of sale.). ( 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions,Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). 1 1 I am exempt under Sec. B.&P.C. for this reason Date: Owner: CONSTRUCTION.LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). - Lender's Name: - Lender's Address: _ LQPERMIT VOICE (760) 777-7012 FAX (760) 777-7011, INSPECTIONS (760) 777-7153 Date: 8/24/07 LN Fi i1 I �t�3 2` 7 u7 11 oil WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: have and will maintain a certificate of consent to self -insure for workers' compensation; as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier STATE FUNDW,ject Num er 756000031107 I certify that, in theork r which this permit is issued, I shall not employ any person in any maject to the workers'. compensation laws of California, and agreethat, ito the workers' compensation provisions of Section 3700 of the Labcomply with those provisions. Date: P WARNING: FAILURE TO SECURE WORKERS' CO ENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,0001. IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. - APPLICANT ACKNOWLEDGEMENT - IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City. of La Quinta, its officers, agents and employees for any act or omission related to the work.being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance Abuildin r cessation of work for 180 days will subject permit to cancellation. certify that I have read this application and state thmation is c ct. I agree to comply with all city and county ordinances and state laws relating totion, an by authorize representatives of thiscounty to enter upon the above-mentioned prion pu o Date: Signature (Applicant or Agent): Application Number 07-00002400 ..Permit . . WALL/FENCE PERMIT - Additional desc . Permit Fee . . . .. 63.00 Plan Check Fee .00 Issue Date. Valuation . . . . 3880 Expiration Date 2/20/08 Qty Unit Charge Per Extension BASE FEE 45.00 2.00 .9.0000 THOU BLDG 2,001-25,000 18.00 ------------------------- Special Notes and Comments 175LF RETAINING WALLS [ENGINEERED] 2001 CBC."THIS-PERMIT IS FOR RETAINING WALL AT SIDE OF PROPERTY ONLY, SEE PLAN. August 24, 2007 3:30:43 PM AORTEGA Fee summary Charged Paid Credited Due ----------------------------------------------- Permit Fee Fee Total •63.00 .00 ---------- .00 63.00 Plan Check Total .00 .00 .00 .00 r-ranrl Tntal r.'t nn nn nn 91 nn ' Bin # City of .La Quinta Building & Safety Division P.O. Box 1504, 78-495 Calle Tampico La Quinta, CA 92253 - (760) 777-7012 Building Permit Application and Tracking Sheet Permit # Project Address:' INWL14 !M6Owner's Name: T kwasxg A. P. Number: Address: Legal Description:, City, ST, Zip: Contractor: fLoin Address: Telephone: F Project Description: City, ST, Zip: Telephone: 9) S1 State Lic. # : CityLic. #: Arch., Engr., Designer: Address: City, ST, Zip: Telephone: Construction Type:, Occupancy: State Lic. #: Project type (circle one): New Add'► Alter Repair Demo Name of Contact Person: Sq. Ft.: # Stories: # Units: Telephone # of Contact Person: Estimated Value of Project: E APPLICANT: DO NOT WRITE BELOW THIS LINE # Submittal Req'd Recd TRACKING _ PERMIT FEES Plan Sets Plan Check submitted tem Amount Structural Calcs. Reviewed, ready for corrections Plan Check Deposit Truss Calcs. Called Contact Person Plan Check Balance Energy Cates. Plans picked up Constructicn Flood plain plan Plans resubmitted Mechanical Grading plan 2nd Review, ready for corrections/issue Electrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked up S.M.I. H.O.A. Approval Plans resubmitted 'Grading IN HOUSE:= '`d Review, ready for corrections/issue Developer Impact Fee Planning Approval Called Contact Person A.I.P.P. Pub. Wks. Appr Date of permit issue School Fees Total. Perm A Fees 55' ►20` CITY OF LA QUINTA - PUBLIC WORKS DEPARTMENT GREEN SHEET PUBLIC WORKS CLEARANCE FOR RELEASE OF BUILDING PERMIT Form updated & effective 11/17/2006 Green Sheet approvals are forwarded to the Building. & Safety Department direct) b ,Public Works. Please DO NOT submit the Green Sheet (Public Works Clearance) Packet to the Public Works Department until. ALL requirements listed below are. complete. Incomplete applications or applications which cannot be processed will be returned to applicant. Developer: G r!" Tract No_: 2gS2,2Tract-Na h fC A A. l D ✓Lot No.(s) /2 Address(s): - The following are the requirements for Public Works Clearance to authorize issuance of a building permit fr ❖ CUSTOM HOMES: PROVIDE ITEMS #2, #3, #4 AND #5 BELOW ❖ . TRACT HOMES:. PROVIDE ITEMS #1 #2 #3 #4 AS APPLICABLE AND #6 BELOW COMMERCIAL BUILDINGS/OTHER: PROVIDE.ITEMS.#1 #2 #3 AND #5 BELOW WALLS: PROVIDE ITEMS #7 BELOW ❖ SIGNS:. PROVIDE ITEMS #8 BELOW I. Attach Pad Elevation Certificates in compliance with the approved design elevation for building Pad. (maximum allowable deviation of - +/- 0.1 foot). Pad Elevation Certificates must be current (within 6 months of current date). If a precise grading plan creates the pad for approval, please. withhold green sheet submittal until a Pad Elevation Certificate can be provid3d, CD Attach geotechnical certification of grading. plan compliance. Attach recorded final map.showing proposed building locations are legal lots. Attach a completed < 1 acre per lot or infill project Fugitive Dust Control project information form, PM10 plan & agreement or provide alternative & valid City approved PM10 plane set reference 'number or hard copy plan. PM 10 plans for commercial & residential developments (beyond 1 lot) are submitted separately with grading plans & are subject to additional requirements. .Attach an approved precise grading plan for'the building location(s). AO flood zone developments will require an approved flood plain development plan.�s� 6. Attach an approved rough grading PP g g g plan for the building location(sl. 7. Attach wall plan & related approved grading.plan.�-� 8. Attach sign layout/plan & gelated precise: grading/landscape plan. J I have reviewed and confirmed the requirements listed above as presented and find the improvements to be sufficiently complete for construction of th proposed buildings/structures/walisrsigns on the subject lot(s). Pursuanti.9 my findin s., the a ove pr .� ct may be released for building permi-E issuance. Recommended by: aDated: - Z/p A �• Public Works Distribution: ( Green Sheet to Building & Safety counter'i'�'�L 1_) Green Sheet to Community Development Declined for approval for reason(s) as follow(s), please correct and resubmit: pct intormation (< 1 acre per. Lot or Infill Project) Page 1 of 3 Form updated & effective 8/25/2005 Project Information Project Phase � / Project Contractor: � Project Phase (Check One): Construction 5/• l0 2S' -�.lrl7< Gly /�%/• �/ Zor' Project Name: Project Tract ' Number:SS'.2 2 ❑ Demolition Lot Number(s): 12. Anticipated Start Date: ^ 2 G -7 Anticipated Completion: Project Street Address: -� ..! Total acres in active construction (< 1 acre per Lot): 32_ 2 -So s • F Project Contact Information Please Note: Dust control is required 24 hours a day, 7- days a week, regardless of construction status. Person listed below is responsible for dust control during business and non- business hours. Name: �• �, Title: t Company Name:,r. Mailing Address: , p,3 So City: State: Zip Code: y2 2 7 Primary Telephone Number: Fax:41 2 24 Hour Access/Emergency Phone: Cell Phone: PM 10 Certificate Number: ❖ Expanded PM 10 plans for commercial and residential developments > 1 acre are required by the City of La Quinta. /le I PM 10 1 < 1 acre per Lot or Infill Project) Fugitive Dust Control Plan Page 2 of 3 Plan updated & effective 8/25/2005 This plan shall take into account applicable SCAQMD Rule 403 regulations. Training may be obtained by contacting SCAQMD (Sharon Zamora - Phone: (909) 396-2183.). This plan shall consist of the following action items: WATERING: Continuous watering is required to prevent dust and must occur a minimum of 4 times daily. Water shall be applied to .dry soils to stop: • Visible dust emissions over 20% opacity • Visible dust emissions that travel over 100 feet. o • Water source 3/4 hch water meter at front (south) side cfp ad. ❖ EDUCATION: Responsible. Dust Control Individual and key y personnel shall attend SCAQMD PM 10 class and obtain PM 10 certificate number prior to construction activity. ❖ WEATHER MONITORING: Wind predictions shall be monitored. ❖ SIGNAGE: Use Coachella Valley Fugitive Dust Control Plan Handbook Construction Site Signage Guidelines. TRAFFIC: Construction traffic shall not be' allowed on the pad, unless absolutely necessary. If vehicles operate on pad, pad shall be kept firm and moist through hose vuatering or sprinklers. Fugitive Dust shall be'prevented by fencing off site to prevent unauthorizec- traffic on pad. (15 mph maximum traffic speed). PARKING: Parking is not allowed on the pad. All vehicles must park on street (at designated areas only). :• TRACK OUT: Provide 24 hour street cleaning and track out. system as app-oved by City Public Works Inspector. (No dirt on public or private roads). 'Track out shall be cleaned up within one hour of incident. ❖ DIRT PILES: Dirt piles shall be limited to 50 cubic yards and built per Cali ornia Building Code grading requirements. Piles shall be kept moist.or covered with tarp material. Larger'dirt.piles will require stockpile..or grading permit. °:• FENCING: Provide PM10 fencing. at perimeter of public roads and where applicable. Wood slat fencing can be installed at rear, of property and return 20 feet on either side if - HOA';restrictions apply. Block walls can replace.PM 10 fencing during the construction. phase. •:• EQUIPMENT: Extra hoses and sprinklers shall be maintained onsite ❖ EXCAVATION MEASURES: All areas to be excavated or graded shall be pre -watered. Water shall be applied during excavation or ,grading operations also. ❖ DUMP TRUCKS: Open top dump trucks to be wet down, moist and tarped prion to leaving site. ❖ INACTIVE SITE: Within 10 days of ceasing of activities, re -vegetate or permanently stabilize as required. of La Quinta - Site Specific Construction Phase PM 10 Agreement Page 3 of 3 Agreement updated & effective 8/25/2005 The signature of the property owner (or authorized representative) ❖ Shall act as his/her acknowledgement of dust control .requirements and their enforceability, .pursuant to AQMD Rules 4p3 and 403.1; ❖ -Shall constitute and agreement to comply with all project conditions as identified in the approved dust control plan; The property owner (or authorized representative): ❖ Acknowledges that dust control is required 24 hours a day,.7 days a week, throughout the period of project performance, regardless of project size or status; ❖ Shall ensure that each and every contractor/subcontractor and all other persons associated with the project shall be in continuous compliance with all requirements of the approved dust control plan; ❖ Shall take all necessary. precautions to minimize dust, even if additional measures beyond those listed in the dust control plan are necessary; Shall authorize representative of the City/County to enter upon the above mentioned property for inspection and/or abatement purposes; and ❖ Shall hold harmless the City/County and its representatives from liability for any actions related to this dust control plan or any City/County initiated abatement activities. Signature of Propert>f Owner or Authorized Representative Printed Name Title Date V440h/ A4 IrlC. Company Patel Bur'ica & Associates, Inc. structural engineering Structural Building Department Submittal for Site Retaining Wall Taylor Residence Peninsula Park at PGA West Lot 12, Tract #28522. 57-175 Peninsula Lane La Quinta, California August 22, 2007 Q�pFESS/ - 4Q�C� pfc-L J. BGl �y No. 5715 E CITY O LA QUINTA j BUILDING & SAFETY DEPT. APPROVED FO INSTRU N PBA Job #276 -SCA 832 W. Town & Country Road • Grange, California 92868 714.547.1115 PH • 714.547.1141 FAX • www.PBAstructural.com - .Patel Burica &Associates, Inc. Table. of Contents , Description Retaining Wall Calculations r • F 27 — F.37 F Title : Taylor Residence Job # 276 SCA Dsgnr: PH Date: 10:03AM, 12 APR 07 Description: Park Peninsula - PGA West Scope : Code Ref: ACI 318-02,1997 LBC, 2003 IBC, 2003 NFPA 5000 User: Kw0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Page 1 (c)1983-2003 ENERCALC Engineering Software 276 see - enercalc.ecw:Calculetions Description 4' Wall At Section I Criteria = 1,500.0 psf Retained Height = 4.00 It Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 120.00 pd r'/slo7 Soil Data Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Toe Active Pressure = 40.0 psf/ft Passive Pressure = 250.0 psf/ft Water height. over heel = 0.0 ft FootingliSoil Friction Wind on Stem - 21.0 psf Soil height to ignore for passive pressure Design Summa Total Bearing Load = 2,812 lbs ...resultant ecc. = 4.54 in = 0.300 = 0.00 in Stem Construction 1,324 psf OK Design height ft = Wall Material Above "Ht" _ Thickness = Rebar Size = Rebar Spacing = Rebar Placed at = Design Data 6.5 psi OK fb/FB + fa/Fa = Total Force @ Section lbs = Moment.... Actual ft-# Moment..... Allowable ft-#= Shear..... Actual psi = Shear..... Allowable psi = Soil Pressure @ Toe = 1,324 psf OK Soil Pressure @ Heel = 282 psf OK Allowable = 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 1,624 psf ACI Factored @ Heel = 346 psf Footing Shear @ Toe = 7.2 psi OK Footing Shear @ Heel = 6.5 psi OK Allowable =. 85.0 psi Wall Stability Ratios 1,114 Overturning = 2.77 OK Sliding = 1.84 (Vertical Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 731.0 lbs less 100% Passive Force- - 500.0 lbs less 100% Friction Force= - 843.5 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK LFooting Design Results 0.00 in Masonry Data Toe Heel Factored Pressure = 1,624 346 psf Mu': Upward = 1,538 718 ft-# Mu'' Downward = 424 2,144 ft-# Mu: Design = 1,114 1,426 ft-# Actual 1 -Way Shear = 7.16 6.52 psi Allow 1 -Way Shear = 85.00 85.00 psi Toe Reinforcing = None Spec'd 7.60 Heel Reinforcing = None Spec'd Key Reinforcing = None Spec'd psi = Footing Strengths & Dimensions fc = 2,500 psi Fy = 40,000 psi Min. As % = 0.0014 Toe Width ' Heel Width Total Footing Width Footing Thickness = 1.25 ft 2.25 _ 33� 18.00 in 0.913 126.0 378.0 414.0 3.0 19.4 Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight Key Width = 0.00 in Rebar Depth 'd' Key Depth = 0.00 in Masonry Data Key Distance from Toe = 1.25 ft fm Cover @ Top = 3.00 in @ Btm.= 3.00 in Ip Stem 2nd 24,000 Stem OK Stem OK Yes 4.00 0.0C No Masonry Masonry 25.78 8.00 10.0C 1.000 # 4 # 7.60 32.00 16.0C Center Edge psi = 0.913 126.0 378.0 414.0 3.0 19.4 Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight psf= 84.0 Rebar Depth 'd' in = 3.81 Masonry Data fm psi= 1,500 Fs psi = 24,000 Solid Grouting = Yes Special Inspection = No Modular Ratio 'n' = 25.78 Short Term Factor = 1.000 Equiv. Solid Thick. in= 7.60 Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = Other Acceptable Sizes 8 Spacings Toe: Not req'd, Mu < S ' Fr Heel: Not req'd, Mu < S ' Fr Key: No key defined 0.72E 441.0 1,307.E 1,801.0 5.E 19.4 30.00 6.00 104.0 7.2E 1,50C 24,OOC Yes Nc 25.7E 1.000 9.62 /'F-27 Title: Taylor Residence Job # 276 SCA Dsgnr: PH , Date: 10:03AM, 12 APR 07 Description : Park Peninsula - PGA West Scope Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 user: KW -0605599, Ver 5.8.0, 1 -Deo -2003 Cantilevered Retaining Wall Design Page 2 (c)1983-2003 ENERCALC Engineering Software 276 see - enercalc.ecw:Calculations Description 4' Wall At Section I Summaa of Overturnins & Resistins Forces & Moments ' ...OVERTURNING..... .....RESISTING..... Force Distance Moment Fore Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 605.0 1.83 1,109.2 Soil Over Heel = 880.0 2.79 1,898.3 Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = '= Added Lateral Load = Axial Dead Load on Stem 0,00 Load @ Stem Above Soil = 126.0 8.50. 1,071.0 Soil Over Toe = 75.0 0.63 46.9 SeismicLoad = Surcharge Over Toe = Stem Weight(s) 920.0 1,62 1,491.3 Total _ 731.0 O.T.M. = 2,180.2 Earth @ Stem Transitions= Resisting/Overturning Ratio = 2.77 Footing Weight. = 737.5 1.75 1,3.78.1 Vertical Loads used for Soil Pressure = 2,811.8 lbs Key Weight = 1.25 . Vert. Component = 319.3 3.50 1,222.5 Vertical component of active pressure used for'soil pressure Total = 2,8h 1.8 lbs R.M.= 6,037.2 Title: Taylor Residence Job # 276 SCA Osgnr: PH Date: 10:1 OAM, 12 APR 07 Description Park Peninsula - PGA West Scope: Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 User: KW0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Page 1 ' (c)1983-2003 ENERCALC Engineering Software 276 sca - enercalc:ecw:Calculations Description 6' Ret Wall w/ 6'. Above 3/slo-) Criteria Soil Data Footing Strengths & Dimensions Retained Height = 6.00 ft Allow Soil Bearing = 1,800.0 psf fc = 2,500 psi fy = 40,000 psi Wall height above soil = 6.00 ft Equivalent Fluid Pressure Method Min. As % = 0.0014 Slope Behind Wall 0.00: 1 Heel Active Pressure - 40.0 psf/ft Toe Width = 1.75 ft Toe Active Pressure = 40.0 psf/ft Heel Width, = 2.75 Height of Soil over Toe = 6.00 in Passive Pressure = 250.0 psVit Total Footing Width Soil Density = 120.00 pcf Water height over heel = 0.0 ft Footing Thickness - 18.00 in FootingllSoil Friction = 0.300 Wind on Stem = 21.0 psf Soil height to ignore Key Width = 12.00 in for passive pressure = 0.00 in Key Depth = 6.00 in Key Distance from Toe = 1.75 It Cover @ Top = 3.00 in @ Btm.= 3.00 in Design Summary ---� Stem Construction 0 Top stem 2nd 3rd Stem OK Stem OK Stem OK Total Bearing Load 4,350 Ibs Design height ft= 6.00 3.3c 0.00 ...resultant ecc. = 3.24 in Wall Material Above "Ht" = Masonry Masonry Masonry Soil Pressure,@ Toe = 1,314 psf OK Thickness Rebar Size 8.00 # 4 8.OG # E 10.00 # 5 Soil Pressure @ Heel = 619 psf OK _ Rebar Spacing 32.00 16.00 16.00, Allowable = 1,800 psf Soil Pressure Less Than Allowable _ Rebar Placed at - Center Edge Edge ACI Factored @ Toe = 1,543 psf Design Data - fb/FB.+ fa/Fa - 0.813 0.781• 0.851 ACI Factored @Heel = 727 psf Total Force @ Section lbs = 126.0 268.E 841.0 Footing Shear @ Toe = 9.9 psi OK Moment.... Actual ft-#= 378.0 841.2 2,573.2 Footing Shear @Heel = . 11.0 psi OK Moment..... Allowable ft-#= 414.0 1,058.0 3,024.4 Allowable = 85.0 psi Shear..... Actual psi = 3.0 4.E 10.6 Wall Stability Ratios Overturning = 3.08 OK Shear ..... Allowable psi = 19.4 19 38.7 Sliding = 1,67 (Vertical Co Bar Develop ABOVE Ht. in= •24.00 30.0C 30.00 Sliding Calcs (Vertical Component Used) Bar Lap/Hook BELOW Ht. in = 24.00 30.00 8.93 Lateral Sliding Force 1,251.0.lbs Wall Weight psf= 84.0 84.0 104.0 less 100% Passive Force= - 781.3 lbs Rebar Depth 'd' in= 3.81 5.2E 7.25 less 100% Friction force= - 1,305.0 lbs Masonry Data Added Force Req'd = 0.0 lbs OK I'm psi= 1,500 1,50C 1,500 ....for 1.5 : 1 Stability = 0.0 lbs OK Fs psi= 24,000 24,000 24,000 Solid Grouting - Yes Yes Yes Footing Design Results Special Inspection No Nc Yes Modular Ratio'n' - • 25.78 25.7E 25.78 Toe Heel Short Term Factor = 1.000 1.000 1.000 Factored Pressure = 1,543 727 psf Equiv. Solid Thick.in = 7.60 7.6C 9.62 Mu': Upward = 2,731 1,931 ft-# Masonry Block Type = Normal Weight Mu': Downward = 765 5,103 ft-# Concrete Data Mu: Design = 1,966 3,173 ft-* rc psi= . Actual 1 -Way Shear = 9.91 11.00 psi Fy psi = , Allow 1 -Way Shear = 85.00 85.00 psi Other Acceptable Sizes & Spacings Toe Reinforcing = None Spec'd Toe: Not req'd, Mu < S " Fr Heel Reinforcing = None Spec'd, Heel: Not req'd, Mu < S' Fir Key Reinforcing = None Spec'd Key: Not req'd, Mu < S * Fr :3� r Title : Taylor Residence Job # 276 SCA ' Dsgnr: PH Date: 10:10AM, 12 APR 07 ! Description : Park Peninsula - PGS. West Scope Code Ref: ACI 318-02, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered RetainingWall Design , Page 2 (c)1983-2003 ENERCALC Engineering Software 276 sca - enercalc.ecw:Calculations Description 6' Ret Wall w/ 6' Above Summary of Overturning & Resisting Forces & Moments ....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# lbs ft ft-# Heel Active Pressure = 1,125.0 2.50 2,812.5 Soil Over Heel =. 1,380.0 3.54 4,887.5 Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = " Added Lateral Load = Axial Dead Load on Stem= 0.00 Load @ Stem Above Soil = 126.0 10.50 1,3211 Soil Over Toe = -05.0 0.88 91.9 SeismicLoad = Surcharge Over Toe = ' Stem Weight(s) = 1,074.6 2,11 2,267.6 Total = 1,251.0 O.T.M. = 4,135.5 Earth @ Stem Transitions= 53.4 2.50 133.5 .. Resisting/Overturning Ratio = 3.08 Footing Weight = 1,C 12.5 2.25 2,278.1 Vertical Loads used for Soil Pressure = 4,350.0 lbs Key Weight = 75.0 2.25 168.7 Vert. Component = E+49.5 4.50 2,922.8 Vertical component of active pressure used for soil pressure Total = 4,Z-60.0 lbs R.M.= 12,750.2. r Title : Taylor Residence Job # 276 SCA Dsgnr: PH Date: 10:13AM, 12 APR 07 Description : Park Peninsula - PGA West Scope Code Ref. ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Page 1 (c)1983-2003 ENERCALC Engineering Software 276 sea - enercalc.em:Celculalions Description 8' Ret Wall w/ 6' Above Criteria = 1,800.0 psf Retained Height = 8.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 120.00 pcf Wind, on Stem = 21.0 psf [Design Summary Total Bearing Load = 6,149 lbs ...resultant ecc. = 2.34 in Soil Data Allow Soil Bearing = 1,800.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Toe Active Pressure = 40.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel. = 0.0 ft FootingljSoil Friction = 0.300 Soil height to ignore for passive pressure = 0.00 in Stem Construction T Design height ft = Wall Material Above "Ht" _ Th'I dk - Soil Pressure @ Toe = 1,356 psf OK Rebarr Size In - = Soil Pressure @ Heel = 881 psf OK Rebar Spacing = Allowable 1,800 psf • Soil Pressure Less Than Allowable Rebar Placed at = ACI Factored @ Toe = 1,535 psf Design Design Data . + fa/Fa fb/FTotal - ACI Factored @ Heel = 997 psf 4,542 3,371 ft-# Mu': Downward = 1,247 9,170 ft-# Mu: Design = Force (a3 Section lbs = Footing Shear @Toe = 13.3 psi OK Moment.... Actual ft-# = Footing Shear @ Heel = 17.3 psi OK Moment..... Allowable ft-# = Allowable = WallRatlos 85.0 psi Shear..... Actual psi = Ov= erturning 9 3 16 OK Shear..... Allowable psi= Sliding = 1.fi4 (Vertical Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 1,931.0 lbs less 100% Passive Forces - 1,320.3 lbs .less 100% Friction Force= - 1,844.8 lbs Added Force Req'd = '0.0 lbs OK ....for 1.5: 1 Stability = 0.0 lbs OK Footing Design Results Fs Toe Heel Factored Pressure = 1,535 997 psf Mu': Upward = 4,542 3,371 ft-# Mu': Downward = 1,247 9,170 ft-# Mu: Design = 3,296 5;800 ft-# Actual 1 -Way Shear =, .13.27 17.32 psi Allow 1 -Way Shear = 85.00 85.00_ psi Toe Reinforcing = None Spec'd Heel Reinforcing = # 5 @ 16.00 in Key Reinforcing = # 4 @ 16.00 in Footing Strengths & Dimensions fc = 2,500 psi Fy = 60,000 psi _ Min. As % = 0.0014 Toe Width = 2.25 ft Heel Width = 3.25 Total Footing Width = -530- Footing Thickness = 18.00 in 0.720 111.9 298.3 414.0 4.0 19.4 Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight Key Width 58.0 = 12.00 in in= Key Depth Masonry Data = 15.00 in 4,798.5 Key Distarnm from Toe = 2.25 ft Fs Cover @ T6p = 3.00 in @ Btm.= 3.00 in ,p Stem 2nd 3rd 4th Stem OK Stem OX Stem OK _ Stem OK 8.67 6.00 3.33 0.00 Masonry Masonry Masonry Masonry 8.00 8.00 10.00 12.00 # 4 # 5 # 5 # 6 32.00 16.00 16.00 8.00 Center Edge Edge Edge 0.720 111.9 298.3 414.0 4.0 19.4 Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight psi= 58.0 Rebar Depth 'd' in= 3.81 Masonry Data 1,645.4 4,798.5 fm psi= 1,500 Fs psi = 24,000 Solid Grouting = No Special Inspection = No Modular Ratio'n' _ '25.78 Short Term Factor = 1.000 Equiv. Solid Thick. in= 4.90 Masonry Block Type = Normal Weight Concrete Data 1,500 24,00[ fc psi = Yes Fy psi = Nc Other Acceptable Sizes & Spacings Toe: Not req'd, Mu < S ' Fr Heel: Not req'd, Mu < S' Fr Key: Not req'd, Mu < S ' Fr 0.640 0.544 0.656 206.0 562.2 1,401.0 683.2- 1,645.4 4,798.5 1,058.0 3,024.4 7,319.8 3.7 7.1 15.0 19.& 38.7. 38.7 30.00 30.00 36.00 30.00 30.00 .6.00 84.0 104.0 133.0 5.2E 7.25 9.00 1,50C 1,500 1,500 24,00[ 24,000 24,000 Yes Yes Yes Nc Yes Yes 25.7E 25.78 25.78 1.000 1.000 1.000 7.6C 9.62 11.62 F3Z ' Title: Taylor Residence Job # 276 SCA Osgnr: PH Date: 10:1 MM, 12 APR 07 • " Description : Park Peninsula - PGA West Scope Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000. Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Page 2 (c)1983-2003 ENERCALC Engineering Software 276 sea - enercalc.ecw:Calculations Description 8' Ret Wall w/ 6' Above Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Fooce Distance Moment Item lbs ft ft-#' lbs It ft-# Heel Active Pressure = 1,805.0 3.17 5,715.8 ` Soil Over Heel = 2,160.0 4.38 9,450.0 Toe Active Pressure = Sloped Soil Over Heel . = Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 126.0 12.50 1,575.0 Soil Over Toe = .135.0 1.13 151.9 Seismicl-oad = Surcharge Over Toe = Stem Weight(s) = 1,254.0 2.66. 3,336.4 Total = 1,931.0 O.T.M. _ 7,290.8 Earth (ail Stem Transitions= 133.4 3.12 415.8 Resisting/Overturning Ratio 3.16 Footing Weight = 1;237.5 2.75 3,403.1 Vertical Loads used for Soil Pressure = 6,149.5 lbs Key Weight _ 187.5 2.75 515.6 Vert. Component = 1,042.1 5.50 5,731.6 Vertical component of alive pressure used for soil pressure r Total = 6,149.5 lbs R.M.=. 23,004.4 t _ Title : Taylor Residence Job # 276 SCA Osgnr: PH Date: 10:18AM, 12 APR 07 Description : Park' Peninsula - PGA West Scope Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec-2003 Cantilevered Retaining Wall Design 276sca-enercalc.ecwPCalgcueletions (c)1983-2003 ENERCALC Engineering Software Description 10' Ret Wall w/ 6'Above l3/Sb7 Criteria = 1,800.0 psf Retained Height = 10.00 ft Wall height above soil = 6.00 ft Slope Behind Wall = 0.00: 1 Height of Soil over Toe = 6.00 in Soil Density = 120.00 pd Wind on Stem = 121.0 psf Design Summary Total Bearing Load = 8,844 lbs ...resultant ecc. 2.18 in Soil Data Allow Soil Bearing = 1,800.0 psf Equivalent Fluid Pressure Method Heel Active Pressure - 40.0 psf/ft Toe Active Pressure = 40.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0.0 it Footing Strengths & Dimensions fc = 2,500 psi Fy = 60,000 psi Min. As % = 0.0014 Toe Width = 2.50 it Heel Width = 4.00 Total Footing Width = 6750- Soil Pressure @ Toe = Footing Thickness = 18.00 in FootingllSoil Friction = 0.300 # S Soil height to ignore Key Width = 12.00 in for passive pressure = 0.00 in Key Depth = 24.00 in 32.00 Key Distan•38 from Toe = 2.50 ft 8.00 Cover @ T=ip = 3.00 in @ Btm.= 3.00 in Stem Construction Top Stem 2nd 3rd 4th Edge Stem OK Stem O < Stem OK Stem OK Design height ft = 10.00 6.00 3.33 0.00 Wall Material Above "Ht" = Masonry Masonry Masonry Masonry Thickness in= 8 00 10 00 12 00 16 00 Soil Pressure @ Toe = 1,589 psf OK Rebar Size = # 4 # S # 5 # 6 Soil Pressure @Heel = 1,133 psf OK Rebar Spacing = 32.00 16.00 16.00 8.00 Allowable = 1,800 psf Soil Pressure Less Than Allowable Rebar Placed at = Center Edge' Edge Edge 5,141 9,929 ft-# Actual 1 -Way Shear = Design Data esig+ Allow l -Way Shear 85.00 85.00 psi Toe Reinforcing = None Spec'd 7.60 Masonry Block Type = Normal Weight ACI Factored @ Toe = 1,753 psf fa/Fa = 0.913 0.72: 0.843 0.611ACI Factored @Heel = 1,250 psf Total Force @ Section lbs= 126.0 446.0 1,015.8 2,121.0 Footing Shear @ Toe= 18.1 psi OK Moment.... Actual ft-#= 378.0 1,308.0 3,196.7 8,303.8 Footing Shear @ Heel = 24.8 psi OK Moment..... Allowable ft-#= 414.0 1,801.0 3,791.3 13,584.4 Allowable = 85.0 psi Shear..... Actual psi = 3.0 5.6 10.3 15.5 Wall Stability Ratios Overturning = 1017 OK Shear..... Allowable psi = 19.4 19.1d 38.7 38.7 Sliding = 1.68 (Vertical Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force = 2,771.0 lbs less 100% Passive Force-- - 2,000.0 lbs less 100% Friction Force= - 2,653.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results 24,000 Toe Heel Factored Pressure = 1,753 1,250 psf Mu': Upward = 6,743 5,972 ft-# Mu': Downward = 1,602 15,900 ft-# Mu: Design = 5,141 9,929 ft-# Actual 1 -Way Shear = 18.06 24.76, psi Allow l -Way Shear 85.00 85.00 psi Toe Reinforcing = None Spec'd Heel Reinforcing = # 6 @ 21.75 in Key Reinforcing = # 4 @ 16.00 in Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight psf = 84.0 Rebar Depth 'd' in= 3.81 Masonry Data 133.0 175.0 I'm psi= 1,500 Fs psi = 24,000 Solid Grouting = Yes Special Inspection = No Modular Ratio'n' = 25.78 Short Term Factor = 1.000 Equiv. Solid Thick. in= 7.60 Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = 30.00 30.00 36.00 30.00 30.00 6.96 104.0 133.0 175.0 7.25 9.00 13.00 1,500 1,500 1,500 24,000 24,000 24,000 Yes Yes Yes No Yes Yes 25.78 25.78 25.78 1.000 1.000 1.000 9.62 11.62 15.62 Other Acceptable Sizes 8 Spacings Toe: Not req'd, Mu < S ' Fr - Heel: #4@ 10.00 in, #5@ 15.50 in, #6@ 21.75 in, #7@ 29.75 in, #8@ 39.00 in, #9@ 4 Key: #4@.16.00 in, #5@ 24.75 in, #6@ 35. �7 f Tide: Taylor Residence • Job # 276 SCA Dsgnr: PH Date:10:18AM, 12 APR 07 Description : Park Peninsula - PGA West Scope: Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Pae 2 g (c)1983-2003 ENERCALC Engineering Software 276 see - enercalc.ecw:Calculations Description 10' Ret Wall w/ 6'Above Summary .of Overturning & Resisting. forces & Moments' ...OVERTURNING.'.... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-# Ibis ft ft-# . Heel Active Pressure = 2,645.0 3.83 , 10,139.2 Soil Over.Heel = 3,200.0 5.17 16,533.3 Toe Active Pressure = Sloped Soil Over Heel = ' Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load 7 Axial Dead Load on Stem = 0.00 Load @ Stem Above Soil = 126.0 14.50 1,827.0 Soil Over Toe = 150.0 '11.25 187.5 SeismicLoad = Surcharge Over Toe = Stem Weight(s) = 1,857.9 2.99 5,552.0 Tota( = 2,771.0 O.T.M. _ 11,966.2 Earth @ Stem Transitions=. 346.8 3.61 1,251.6 Resisting/Overturning Ratio = 3.27 Footing Weight = 1,462.5 3.25 4,753.1 Vertical Loads used for Soil Pressure = 8,844.2 lbs Key Weight = 300.0 3.00 900.0 Vert. Component = 1,527.1 •6.50 9,926.1 Vertical component of active pressure used for soil pressureTotal = 8,344.2lbs R.M = 39,103.7 Title : Taylor Residence Job # 276 SCA Dsgnr: PH Date: 10:34AM, 12 APR 07 Description : Park Peninsula- PGA West Scope: Code Ref: ACI 318-02,1997 UBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 Cantilevered Retaining Wall Design Page . 1 (c)1983-2003 ENERCALC Engineering Software 276 sca - enercalc.ecw:Calculations Description 12' Ret Wall w/ 6' Above ws'07 I.Criteria = 40.0 psf/ft Retained Height = 12.00 it Wall height above soil = 6.00 ft Slope Behind Wall = 0.00:1 Height of Soil over Toe = 12.00 in Soil Density = 120.00 pcf . Wind on Stem = 21.0 psf Design Summary Total Bearing Load = 11,634 lbs ...resultant ecc. = 2.07 in Soil Data Allow Soil Bearing = 1,800.0 psf Equivalent Fluid Pressure Method Heel Active Pressure = 40.0 psf/ft Toe Active Pressure = 40.0 psf/ft Passive Pressure = 250.0 psf/ft Water height over heel = 0,0 It FootingllSoil Friction = 0.300 Soil height to ignore ACI Factored @ Toe. = for passive pressure = 0.00 in Stem Construction . Design height ft = Wall Material Above "Ht" _ Thickness in = Soil Pressure @ Toe = 1,765 psf OK Rebar Size = Soil Pressure @ Heel = 1,337 psf OK Rebar Spacing in = Allowable = 1,800 psf Soil Pressure Less Than Allowable Rebar Placed at - ACI Factored @ Toe. = 1,933 psi Design Data fb/FB + fa/Fa = ACI Factored @ Heel = 1,465 psf 1,933 1,465 psf Mu': Upward = 10,356 9,419 114 Mu': Downward = Total Force @ Section lbs = Footing Shear @ Toe = 23.4 psi OK Moment.... Actual - ft-#= Footing Shear @ Heel = 34.5 psi OK Moment..... Allowable ft-#= Allowable = 85.0 psiWall Shear ..... Actual psi = ility Ratios psi = Fy Overtmon9 = 3 25 OK Shear..... Allowable psi = Sliding = 1.75 (Vertical Co Sliding Calcs (Vertical Component Used) Lateral Sliding Force , = 3,771.0 lbs less 100% Passive Force= - 3,125.0 lbs less 100% Friction Force= - 3,490.3 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 : 1 Stability = 0.0 lbs OK Footing Design Results annomago� ::A 13,403.3 Toe Heel Factored Pressure = 1,933 1,465 psf Mu': Upward = 10,356 9,419 114 Mu': Downward = 2,683 25,606 ft-# Mu: Design = 7,672 16,187 ft-# Actual 1 -Way Shear = 23.39 34.52 psi Allow 1 -Way Shear = 85.00 85.00 psi Toe Reinforcing = # 5 @ 16.00 in Heel Reinforcing = # 7 @ 16.00 in Key Reinforcing = # 4 @ 16.00 in 1p Stem Stem OK 12.66 Masonry 8.00 # 4 32.00 Center Footing :Strengths & Dimensions fc = 2500 psi Fy = 60,000 psi Min. As % = 0.0014 Toe Width Heel Width Total Footing Width Footing Thickness Key Width Key Depth Key Distance from Toe Cover @ Top = 3.00 in 2nd Stem OC 10.0C Masonry 8.0C # 4 16.00 Edge 3rd Stem OK 7.33 Masonry 10.00 # 5 16.00 Edge = 3.00 ft 4.50 = 73tf 18.00 in = 12.00 in 30.00 in 3.00 ft Cad Btm.= 3.00 in . 4th Stem OK 4.66 Masonry 12.00 # 5 8.00 Edge Bottom Stem OK 0.00 Masonry 16.00 # 8 8.00 Edge 0.723 0.75E 0.914 0.602 0.823 112.1 206.0 562.2 1,203.5 2,986.0 299.4 6832 1,645.4 3,939.2 13,403.3 414.0 905.4 1,801.0 6,548.8 16,287.7 2.7 3.E 7.1 12.7 22.5 19.4 19.4 19.4 38.7 38.7 Bar Develop ABOVE Ht. in = 24.00 Bar Lap/Hook BELOW Ht. in = 24.00 Wall Weight' psf= 84.0 Rebar Depth 'd' in = 3.81 Masonry Data 8.63 84.0 Pm psi = 1,500 Fs psi = 24,000 Solid Grouting = Yes Special Inspection 25.78 No Modular Ratio 'n' = 25.78 Short Term Factor = 1.000 Equiv. Solid Thick. in= 7.60 Masonry Block Type = Normal Weight Concrete Data fc psi = Fy psi = 24.00 30.00 30.00 48.00 24.00 30.00 30.00 8.63 84.0 104.0 133.0 175.0 5.25 7.25 9.00 13.00 1,500 1,500 1,500 1,500 24,000 24,000 24,000 24,000 Yes Yes Yes Yes No No Yes Yes 25.78 25.78 25.78 25.78 1.000 1.000 1.000 1.000 7.60 9.62 11.62 15.62 Other Acceptable Sizes 8 Spacings Toe: #4@ 10.00 in, #5@ 15.50 in, #6@ 21.75 in, #7@ 29.75 in, #8@ 39.00 in, #9@ 4 Heel: #4@ 7.25 in, #5@ 11.25 in, #6@ 15.75 in, #7@ 21.50 in, #8@ 28.25 in, #9@ 35 Key: #4@ 16.00 in, #5@ 24.75 in, #6@ 35. X 3 40 Title : Taylor Residence Job # 276 SCA . Dsgnr. PH Date: 10:34AM, 12 APR 07 Description : Park Peninsula - PGA. West Scope Code Ref: ACI 318-02, 1997 LBC, 2003 IBC, 2003 NFPA 5000 Rev: 580014 User: KW -0605599, Ver 5.8.0, 1 -Dec -2003 F Cantilevered Retaining Wall Design Page' 2 (c)1983-2003 ENERCALC Engineering Software 276 sca - enercalc.ecw:Calculations Description 12' Ret Wall w/ 6' Above Summary of Overturning & kesistina Forces & Moments .....OVERTURNING.:... .....RESISTING..... Force Distance Moment Force Distance Moment Item lbs ft ft-#. Ibs ft ft-# Heel Active Pressure = 3,645.0 4.50 16,402.5 Soil Over Heel = 4,560.0 5.92 26,980.0 Toe Active Pressure = Sloped Soil Over Heel = Surcharge Over Toe Surcharge Over Heel = Adjacent Footing Load _ Adjacent footing Load = Added Lateral Load = Axial Dead Load on Stem= 0,00 Load @ Stem Above Soil = 126.0 16.50 2,079.0 Soil Over Toe _ 360.0 1.50 540.0 SeismicLoad = Surcharge Over Toe Stem Weight(s) = 2,-420.3 3.50 Total = 3,771.0 O.T.M. _ 18,481.5 Earth @ Stem Transitions= 427.0 •7,421.8 4.07 1,739,2 Resisting/Overturning Ratio = 3.25 Footing Weight = 1,687.5 3.75 6,328.1 Vertical Loads used for Soil Pressure = 11,634.2 lbs Key Weight = 375.0 3.50 1,312.5 . 4 .Vert. Component = . 2, X04.4 7.50 15,783.3 Vertical component of active pressure used for soil pressure Total = , 11,634.2 lbs + R.M.= 60,104.8 i.