Loading...
05-3281 (SFD)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 �e . Application Number: 1141 C_05_0- 00 03281 Property Address: 57270 PENINSULA LN APN: 762-150-019- - - Application description: DWELLING - SINGLE FAMILY Property Zoning: LOW DENSITY RESIDENTIAT Application valuation: 408599 Applicant: c&ty/ 4 !4 " BUILDING & SAFETY DEPARTMENT BUILDING PERMIT DETACHED Architect or Engineer: Lic. No.: OOR SQUARE FOOT LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and ofsionals Code, and my License is in full force and effect. License Class: B1 License No.: 838041 Dam: ` M 'O 5C �ct OWNER -BUILDER DECLARATION I hereby affirm under penalty of perju that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: (_ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered -for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). (_ 1 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License. Law.). ( ) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: _ Lender's Address: LQPERMIT Owner: BELLA OCEANA LTD PARTNERSHIP 1354 BELLA OCEANA VISTA PACIFIC PALISADES, CA 9027 Contractor: SOUTHERN HILLS DEVELOPMENT 78150 CALLE TAMPICO STE 1C LA QUINTA, CA 92253 (760)771-3497 Lic. No.: 838041 VOICE (760) 777-7012 FAX (760) 777-7011 INSPECTIONS (760) 777-7153 Date: 12/27/05 • WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier EXEMPT Policy Number EXEMPT I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject o the workers' compensation provisions of Section A 3700 of the Labor Code I shall forthwith c with those provisions. Da e:t�a- � Applic WARNING: FAILURE TO SECURE WO 'COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P NALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000) IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to the Director of Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building cons�r ction, and hereby authorize representatives of this county to enter upon the above-mentione prop rty for 'nsp ti purposes. , P,� Signatu� a IApplicantor- entt _ _ _ Application Number . . . . . 05-00003281 E9 Permit• . . . . . BUILDING PERMIT ' Additional desc . Permit Fee . . . . 1721.00 Plan Check Fee 1118.65 Issue Date . . . . Valuation . . . 408599 Expiration Date Qty Unit Charge Per Extension BASE FEE 639.50 309.00 ------------------------------------------------- 3.5000 THOU RIdDC; 1.00.001.-500.000 --------------------------- 1.081.50 Permit . . . ELEC-NEW RESIDENTIAL Additional desc . Permit Fee . . . . 209.33 Plan Check Fee 52.33 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 6/21/06 Qty Unit Charge Per Extension BASE FEE 15.00 4538.00 .0350 ELEC NEW RES - 1 OR 2 FAMILY 158.83 1025.00 .0200 ELEC GARAGE OR NON-RESIDENTIAL 20.50 1.00 15.0000 EA ELEC TEMPORARY POWER POLE 15.00 Permit . . . GRADING PERMIT Additional desc ". . Permit Fee . . . . 15.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/21/06 Qty Unit Charge Per Extension ---------------------------------------------------------------------------- BASE FEE 15.00 Permit . . . MECHANICAL Additional desc '. Permit Fee . . . . 132.50 Plan Check Fee 34.75 Issue Date . . . . Valuation . . . . 0 Expiration Date 6/21/06 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 9.0000 EA MECH FURNACE <=100K 36.00 4:00 9.0000 EA MECH B/C <=3HP/100K BTU 36.00 6.00 6.5000 EA MECH VENT FAN 39.00 1.00 6.5000 EA MECH EXHAUST HOOD 6.50 LQPE%-,IIT Application Number . . . . . 05-00003281 s Permit . . . . . . PLUMBING Additional desc . Permit Fee . . . . 219.75 Plan Check Fee 51.19 } Issue Date . . . . Valuation 0 Expiration Date 6/21/06 Qty Unit Charge Per Extension BASE FEE 15.00 23.00 6.0000 EA PLB FIXTURE 138.00 1.00 15.0000 EA PLB BUILDING SEWER 15.00 2.00 7.5000 EA PLB WATER HEATER/VENT 15.00 1.00 3.0000 EA PLB WATER INST/ALT/REP 3.00 1.00 9.0000 EA PLB LAWN SPRINKLER SYSTEM 9.00 13.00 .7500 EA PLB GAS PIPE >=5 9.75 1.00 15.0000 EA PLB GAS METER 15.00 ---------------------------------------------------------------------------- Special Notes and Comments 4538 sq. ft. SFD THIS PERMIT DOES NOT INCLUDE POOL & SPA BLOCK WALLS OR DRIVEWAY APPROACH. - Other Fees .. . . . . . . . . ART IN PUBLIC PLACES -RES 521.49 DIF COMMUNITY CENTERS -RES 74.00 DIF CIVIC CENTER - RES 480.00 ENERGY REVIEW FEE 111.87 DIF FIRE PROTECTION -RES 140.00 GRADING PLAN CHECK FEE .00 DIF LIBRARIES - RES 355.00 DIF PARK MAINT FAC - RES 22.00 DIF PARKS/REC - RES 892.00 STRONG MOTION (SMI) - RES 40.85 DIF STREET MAINT FAC -RES 67.00 DIF TRANSPORTATION- RES 1666.00 Fee summary Charged Paid Credited ---------------------------------------- Due ----------------- Permit Fee Total 2297.58 .00 .00 2297.58 Plan Check Total 1256.92 500.00 .00 756.92 Other Fee Total 4370.21 .00 .00 4370.21 Grand Total 7924.71 500.00 .00 7424.71 LQPER\41T g �-s -A--Ah,vsW_A PkA-k- ILOT(6 uuti%v PO. BOX 1504 APPLICATION ONLY 78 495 CALLE TAMPICO ki./4 QUINTA, CALIFORNIA 92253 Address.5b_!gJ7 _&)A5JJJp)67d11 571= *237 T7 L L-4- Qu i ew I `I?n S3 tk -?i- 3X571 & Classif. T36 D LN Lic. # ! Arch., Engr., /� ,I - Designer hS Ql� �-�/ IA/77�-t %C 20371 AW #I -&-D 14�►�-Cf�C31 YZ7 ILic. # LICENS CONTR TOR'S DECLARATION 1 hereby affirm that a lice under ro Bions of Chapter 9 (commencing with Section 7000) of Div' ' 3 B ess and o ssions Code, and my license is in full force and„ effect. Z V -OS SIGNATURE DATE OWNER -BUILDER DECLARATION I here ffirm that I am exempt from the Contractor's License Law for the following reason: (Sec. 7031.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law, Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500). ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec. 7044, Business and Profes- sions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or im- provement is sold within one year of completion, the owner -builder will have the burden of proving that he did not build or improve for the purpose of sale). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ 1 am exempt under Sec. B. & P.C. for this reason WORKER'S COMPENSATION DECLARATION I hereby affirm that I have a certificate of consent to self -insure, or a certificate of Worker's Compensation Insurance, or a certified copy thereof. (Sec. 3800, Labor Code.) Policy No. Company ❑ Copy is filed with the city. ❑ Certified copy is hereby furnished. CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed if the permit is or one hundred dollars ($100) valuation or less). I certify that in the performance a jc�subje whi thi permit is issued, I shall not employ any person in any manner so to beto orkers' Compensation Laws of Calif =t� � Date L Owner NOTICE TO APPLICANT. 1/, a making this Cer icate of Exemption you should become subject to the Workers' C p Batton provisions of the Labor Code, you must forthwith comply with such provision his permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued. (Sec. 3097, Civil Code.) Lender's Name Lender's Address This is a building permit when properly filled out, signed and validated, and is subject to expiration if work thereunder is suspended for 180 days. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter the above-mentioned property for inspection purposes. Signature of applicant Date Mailing Address City, State, Zip WHITE = BUILDING DEPARTMENT BUILDING: TYPE CONST. P. OC3. GR A.P. Number :%7_ I -Q) Legal Description boor - %%✓L% Z����� )Z // Project Description 5( &L.Ej�Agl Ly ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback frorm Property Line FINAL DATE_ Issued by: Validated by:_ Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Sq. Ft. -3 J V Size J I�T No. Stories No. Dw. Units New ❑ Add ❑ Alter ❑ Repair ❑ Demolition ❑ CONI;+CT Estimated Valuation PERMIT AMOUNT Plan Chk. Dep. , �Q Plan Chk. Bal. Const. Mech. Electrical Plumbing S.M.I. Grading Driveway Enc. Infrastructure TOTAL 0 0 11 : REMARKS ut-LAQUINTA— EIFNApir-r- J ZONE: BY: Minimum Setback Distances: Front Setback from Center Line Rear Setback from Rear Prop. Line Side Street Setback from Center Line Side Setback frorm Property Line FINAL DATE_ Issued by: Validated by:_ Validation: YELLOW = APPLICANT INSPECTOR Date Permit PINK = FINANCE Coachella Valley Unified School District 83-733 Avenue 55, Thermal, CA 92274 . (760) 398-5909 — Fax (760) ,398-1224 This Box For District Use Only DEVELOPER FEES PAID AREA: AMOUNT ' LEVEL ONE AMOUNT: LEVEL TWO AMOUNT: MITIGATION AMOUNT: COMM/PND. AMOUNT: nATF., RF.CF.IPT r..4F.r..K 9- rNITIAI.C- CERTIFICATE OF COMPLIANCE (California Education Code 17620). Project Name: Peninsula Lane PGA Date: January 4, 2006 Owner's Name: Southern Hills Development Phone No. 9a -4119d Project Address: 57-270 Peninsula Lane La Quinta, CA Project Description: 1 SFD APN: 762-150-019 Tract #: Lot #'s: ' Type of Development: Residential XR Commercial Industrial Total Square Feet of Building Area: 4,538 sq. ft. Certification of Applicant/Owners: The person signing certifies that the above information is correct and makes this statement under penalty of perjury and further represents that he/she is authorized to sign on behalf of the owner/developer. Dated: -January 4, 2006 Signature: SCHOOL DISTRICT'S REQUIREMENTS FOR THE ABOVE PROJECT HAVE BEEN OR WILL BE SATISFIED IN ACCORDANCE WITH ONE OF THE FOLLOWING: (CIRCLE ONE) Education Code Gov. Code Project Agreement Existing Not Subject to Fee 17620 65995 Approval Prior to 1/1/87 Requirement Nate -, Number of S4.Ft. 4,538 Amount per Sq.Ft. $2.88 , Amount Collected $13,069.44 Building Permit Application Completed: Yes/No By: Carey M. Carlson, Asst. Supt., Business Services , Certificate issued by: ElAra Mattson, Office Technician Signature: �� jlt G % �c ' NOTICE OF 90 DAY PERIOD FOR PROTEST OF FEES AND STATEMENT OF FEES Section 66020 of the Government Code asserted by Assembly Bill 3081, effective January 1, 1997, requires that this District provide (1) a written notice to the project appellant, at the time of payment of school fees, mitigation payment or other exactions ("Fees"), of the 90 -day period to protest the imposition of these Fees and (2) the amount of the fees. Therefore, in accordance with section 66020 of the Government code and other applicable law, this Notice shall serve to advise you that the 90 -day protest period in regard to such Fees or the validity thereof, commences with the payment of the fees or performance of any other requirements as described in section 66020 of the Government code. Additionally, the amount of the fees imposed is as herein set forth, whether payable at this time or in whole or in part prior to issuance of a Certificate of Occupancy. As in the latter, the 90 days starts on the date hereof. This Certificate of Compliance is valid for thirty (30) days from the date of issuance. Extension will begranted only for good cause, as determined by the School District, and up to three (3) such extensions may be granted. At such time as this Certificate expires; if a building permit has not been issued for the' project that is the subject of this Certificate, the owner will be reimbursed all fees that were paid to obtain this Certificate of Compliance. :'bi t•:Cc 171vdi%CS(Ie\lee %Cerlll)Citte of curnpl3afice (Oral tables t'O i.;:S f:>.doc - _ 1/16/03 T v TITLE 24 REPORT " r. Title 24 Report for: Lot #8 57-270:Pbninsula Lane @ PGA West La Quinta, CA 92253 r . Project Designer: Southern Hills Development, Inc. 78-150 Calle Tampico, Suite #101 La Quinta, CA 92253 (760) 771-349.7 Report Prepared By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346=0855 C ITY OF LA Q111N� A DING & SAFETY D Job. Number:APPR®�/ED . OR CONS l� CTIO �� Z`�21o� B Date: 7/19/2005, The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415)883-5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 r TABLE OF CONTENTS Cover Page _ 1 Table of Contents 2 Form CF -1 R Certificate of Compliance 3 Form..MF-1 R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 13 HVAC System Heating and Cooling Loads Summary 15 Room Load Summary 18 Room Heating Peak Loads 21 Room Cooling Peak Loads 24 Certificate of Compliance: Residential (Part 1 Of 2) CF -1 R Lot #8 A /19/2005 Project Title Date 57-270 Peninsula Lane (W_ PGA West La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Pian Check/ Date Documentation Author Telephone Computer Performance 15 Field Check/ Date. Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 3,904 ft2 Average Ceiling Height: 10.9 ft Total Conditioned Slab Area: 3,,904 ft2 Building Type: (check one or more) X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor rCIVCa I mA 11VIV Location/Commems Jc. aaraae, tvoicale etc. Exterior Roof Exterior Wall Exterior Wall Exposed Slab w/R-0.0 Perimeter Insulaton Covered Slab w/R-0.0 Perimeter Insulation Exterior Door anaoing wevlces Type Orientation Area Const. Component Frame Assembly Type Type U -Value R-38 Roof (R.38.2x14.16) Wood 0.028 W-1 Wall (W.21.2x6.16) Wood 0.057 W-2 Wall (W.21.2x6.16) Wood 0.057 Slab On Grade n/a 0.756 . Slab On Grade n/a 0.756 Solid Wood Door Wood 0.387 rCIVCa I mA 11VIV Location/Commems Jc. aaraae, tvoicale etc. Exterior Roof Exterior Wall Exterior Wall Exposed Slab w/R-0.0 Perimeter Insulaton Covered Slab w/R-0.0 Perimeter Insulation Exterior Door anaoing wevlces Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Left 96.8 0.55 0.30 Bug Screen ❑ Q ❑ X❑ Left 3.0 0.40 0.35 Bug Screen ❑ 0 ❑ 0 Rear 160.0 0.80 0.59 Bug Screen ❑ x❑ ❑ X❑ Rear 79.0 0.40 0.35 Bug Screen ❑ Q ❑ Q Left 19.5 1.19 0.68 Bug Screen ❑ _R1 ❑ X❑ Rear 29.3 1.19 0.68 Bug Screen ❑ X❑ ❑ X❑ Rear 39.0 0.40 0.35 Buq Screen x❑ ❑ ❑ x❑ Right 29.4 0.55 0.30 Bug. Screen X❑ ❑ ❑X❑ Front 104.0 '0.80 0.59 Bug Screen Q -1 ❑ X❑ Front 16.0 0.40 0.35 Bug Screen ❑ X❑ ❑ Q Right 54.8 0.40 0.35 Bug Screen ❑ 0 ❑ Q Right 128.0 0.80 0.59 Bug Screen X❑ ❑ ❑ Q Run Initiation Time: 07119105 08: 3:5 Run Code: 1121786037 Ener Pro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 3 of 27 Certificate of Compliance: Residential (Part 2 of 2) CF -1 R Lot #8 7/19/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design:Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnarp 80% AFUE Ducts in Attic 4.2 Sethack HVAC -1 (Sleeping) Gentmi Furnarp 80% AFUE Ducts in Attic 49 Sethack HVAC -2 (Sethack) Central Furnace 80% AFUE Ducts in Attic 4.2 Setback HVAC -3 -(Living) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat LocEtion / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Corr-irtents Split Air Conditioner Split Air Conditioner Split Air Conditioner WATER HEATING SYSTEMS Rated 1 Tank Energy Fact,! 1 External Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency Loss (%) R -Value A.O. SMITH FPS -50-224 Small Gas Recirc/Time+Temp 2— 43,000 50_ 0.60 n/a n/a 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with title 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate. has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requires• installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) A'. . Documentation Author Name: Title/Firm: Southern Hills Development, Inc. Address: 78-150 Calle Tampico. Suite#101 La Quinta, CA 92253 Telephone: (760) 771-3497 Lic. #: (signature) (date) Enforcement Agency Name: Title/Firm: Address: Telephone: Name: CJ Mcfadden Title/Firm: BREEZE AIR CON DITIOMING Address: 75-145 ST. CHARLES PLACE PALM DESERT, CA 922.99 Telephone: (760) 346-0855 71 i4/0S (signature) (date) IEnergyPro 3.1 By EnergvSoft User Number. 3665 Job Number. Paae:4 of 27 1 Certificate of Compliance: Residential (Adde-idum) CF -1 R Lot #8 7/19/2005 Project Title _ Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and. documentation; and special verification to be used with the performance approach. The local • enforcement agencv determines the adeguacv of the iustification, and may refect a building or design that otherwise complies )ased on the adequacy of the special justification and documentation submitted. Plan Field The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. The HVAC System "HVAC -1 (Sleeping)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residen,_ial Manual. The HVAC System "HVAC -2 (Setback)" includes credit for a Radiant Barrier installed per Section 8.13 of the Resident al Manual. The HVAC System "HVAC -3 (Living)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3 (Living) includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a Form CF -6R. plan I Field The HVAC System "HVAC -1 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS ®ter must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Sleeping)" is using reduced duct leakage to comply and must have diagnostic site testing of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2 (Setback)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS; rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Setback)" is using reduced duct leakage to comply and must have diagnostic site testingiof duct leakage .r performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3 (Living)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Living)" is using reduced duct leakage to comply and must have diagnostic site testing of ductleakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. 1 EnergyPro 3.1 - By EnergySoft User Number. 3665 Job Number. Paoe:5 of 27 1 Mandatory Measures Checklist: Residential. (Page 1 of 2) MF -1 R NOTE: Lowrise residential buildings subject.to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. Wher this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specificztions for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if, not applicable. ' DESIGNER ENFORCEMENT Building Envelope Measures "§ 150(a): Minimum R-19 ceiling insulation. ❑ §150(b): Loose fill insulation manufacturer's labeled R -Value. * §150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ` X not apply to exterior mass walls). ❑ * § 150(d): Minimum R-13 raised floor insulation in framed floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 perm/inch. ❑X , §118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® § 116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls q, 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. i 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain' Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. ❑X § 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System,Measures ❑X § 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. §150(i): Setback thermostat on all applicable heating and/or cooling systems. a§1500): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 3. Back=up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal1extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:6 of 27 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION, Instructions: Check or initial applicable boxes. or enter N/A if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ '§ 150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed,with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. i 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑§1`14: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional Inlets and a circulation pump time switch. a§115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light. (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑' §118 (f): Cool Roof material meet specified criteria Lighting Measures © § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. - §150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched at the entrance to the room or one of the alternative to this requirement allowed in Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number. Page:? of 27 Computer Method Summary (Part: 1 of 3) C -2R Lot #8 7/19/2005 Project Title Date 57-270 Peninsula Lane 65- PGA West La Quinta Project Address Building Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/Date Documentation Author Telephone Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 2.89 Facing North Margin COMPLIES Facing East Margin This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical Facing South Margin Total Conditioned Floor Area: Facing West Margin 2.87 0.02 3.34 -0.45 3.77 -0.88 3.44 -0.55 Space Cooling 33.40 29.64 3.76 Building Front Orientation: 30.71 2.69 Total Fenestration Area: 28.91 4.50 Number of Dwelling Units: 31.73 1.67 Domestic Hot Water 7.30 7.85 -0.55 Number of Stories: 7.85 -0.55 3,904 ft 7.85 -0.55 7.85 -0.55 40.36 3.24 41.90 1.69 40.53 3.06 1 43.02 0.57 Totals 43.59 R-38 Roof (R_382x14.16) 70NF.1 V!/.all- 153 0.057 0 g0_ BUILDING ZONE INFORMATION # of The-mostat Vent Zone Name Floor Area Volume Units Zone Type -ype Hgt. Area HVA -1 T(Sleepingj 1 don 14 SFn n 36_ Sleeping SleapingStnt 9 n (: HVA -2 (Sathac16 135 15 09 035 rnriditinned_ Setback 2 n/� HVA(: - 1 15n 13 110 029 1 iving I ivinBStat _2 n/� OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments ROD.f- 1.400 0.028 345 0 0_SIL BUILDING COMPLIES R -3R Rnnf (R 3A 2x14.161 7QNF 1 W-1 Wall 21 2x6 16) 70NF 1 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all oaentations. Total Conditioned Floor Area: 3,904 ft Wall - 125 n 057 -0 go Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor ❑X Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 19.4% Number of Dwelling Units: 1.00 Total Conditioned Volume: 42,699 ft 3 2 Number of Stories: 1 Total Conditioned Slab Area: 3,904 ft BUILDING ZONE INFORMATION # of The-mostat Vent Zone Name Floor Area Volume Units Zone Type -ype Hgt. Area HVA -1 T(Sleepingj 1 don 14 SFn n 36_ Sleeping SleapingStnt 9 n (: HVA -2 (Sathac16 135 15 09 035 rnriditinned_ Setback 2 n/� HVA(: - 1 15n 13 110 029 1 iving I ivinBStat _2 n/� OPAQUE SURFACES Solar Act. Gains Type Area U -Val. Azm. Tilt Y / N Form 3 Reference Location / Comments ROD.f- 1.400 0.028 345 0 0_SIL ®❑ LJ R -3R Rnnf (R 3A 2x14.161 7QNF 1 W-1 Wall 21 2x6 16) 70NF 1 20 0.057 ❑ ON Wall - 125 n 057 -0 go ❑ W-2 Wall (W91 2x6 16) 70NF 1 Wall 607 _ 0.057 90 90 /all 220 0.057 180 gn ❑ W-1 Wall ON 21 2x6 18) 7t)NF 1 W-1 Wall (W 21 2x6 16) 7n_NF 1 Rnnf (R 1d 1 7()NF 2 _ Boot- 1,354 0.028 345ElR-3R _/all_ 239 0.057 0 90 Dnnr 21 0.387 0 9Q El ❑ Wall fW 21 2x6 16) 70NF 2 Sn1id Wnnd Dnnr 70NF 2 W211 52 0.057 _ 90 ryI W-1 Wall ON 7j 2x6 19) 70NF 2 _90 Wall 35 n n57 9) ❑ ❑ ❑ W-2 1t1/a2x6 16 7()NF 2 W-1 Wall 6N?1 2x6 16) 70NF 2 W-1 Wall ON 21 2x6.161 70NF: 2 _90 Wall 94 0.057 180 go Wall 221 0.057 270 - 90 Roof 1 ]50 0.028 345 0 L& El ❑ R-38 Roof (R_382x14.16) 70NF.1 V!/.all- 153 0.057 0 g0_ W-1 W* all (V'V 91 9X61£,) 7QNF 3 Wall 126 0.057 180 90 ❑ ❑ W-1 Wall (W 21 2x6 16 7nNF 3 W-1 Wall pN 21 2x6 16 70NF 3 V1/all 419 _x"057 270 go❑ F -1F__1 ❑❑❑❑ ❑❑❑ Run Initiation Time: 9 Code: 3.1 By EnergySoft User Number. 3665 Page:8 of 27 Computer Method Summary (Part. 2 of 3) C -2R Lot #8 7/19/2005 Project Title Date FENESTRATION SURFACES # Type 0.76 Area U- Factor SHGC Act. Glazing Type Azm. Tilt Location/ Comments J Window Left (Fact) 29-4 0-550 n_30 _ 90 qn Fleetwood Glazing ZGNF 1 2 Window Left (East) 8.0 0.550 0.30 90 90 Fleetwood Glazing ZONE 1 3 Window Left (East) 8.0 0.550 0.30 90 90 Fleetwood Glazing ZONE 1 4 Window Left (East) 29.4 0.550 0.30 90 90 Fleetwood Glazing ZONE 1 5 Window Left (East) 3.0 0.400 0.35 90 90 Fleetwood Glazing ZONE 1 6 Window Left (East) 22.0 0.550 0.30 90 90 Fleetwood Glazing ZONE 1 7 Window Rear (South) 40.0 0.800 0.59 180 90 Fleetwood Glazing ZONE 1 8 Window Rear (South) 40.0 0.800 0.59 180 90 Fleetwood Glazing ZONE 1 5 Window Rear (South) 20.0 0.400 0.35 180 90 Fleetwood Glazing ZONE 1 1Q Window Left (East)_ 19.5 1,190 x.68_ 0 90 Default Single Metal Tinted ZONE 2 1 Window Rear (South) 29.3 1.190 0.68 180 90 Default Single Metal Tinted ZONE 2 12 Window Rear (South) 39.0 0.400 0.35 180 90 Fleetwood Glazing ZONE 2 -U Window Right ONes4 29.4 0.550 0.30 270 90 Fleetwood Glazing ZONE 2 14 Window Front (North) 64.0 0.800 0.59 0 90 Fleetwood Glazing ZONE 3 15 Window Front (North) 16.0 0.400 0.35 0 90 Fleetwood Glazing ZONE 3 16 Window Front (North) 40.0 0:800 0.59 0 90 Fleetwood Glazing ZONE 3 17 Window Rear (South) 40.0 0.800 0.59 180 90 Fleetwood Glazing ZONE 3 18 Window Rear (South) 40.0 0.800 0.59 180 90 Fleetwood Glazing ZONE 3 19 Window Rear (South) 20.0 0.400 0.35 180 90 Fleetwood Glazing ZONE 3 20 Window Rear (South) 39.0 0.400 0.35 180 90 Fleetwood Glazing ZONE 3 21 Window Right (West) 22.8 0.400 0.35 270 90 Fleetwood Glazing ZONE 3 22 Window Right (West) 64.0 0.800 0.59 270 90 Fleetwood Glazing ZONE 3 23 Window Right (West) 16.0 0.400 0.35 270 90 Fleetwood Glazing ZONE 3 24 Window Right (West) 64.0 0.800 0.59 270 90 Fleetwood Glazing ZONE 3 25 Window Riqht (West) 16.0 0.400 0.35 270 90 Fleetwood Glazing ZONE 3 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. REA. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4• Bug Screen 0.76 5 Bug Screen 0.76 6 Bug Screen 0.76 7 Bug Screen 0.76 C, Bug Screen 0.76 9 Bug Screen 0.76 10 Bug Screen 0.76 11 Bug Screen 0.76 12 Bug Screen_ 0.76 6.5 6.0 8.0 0.1 8.0 8.0 13 Bug Screen 0.76 5.5 2.7 10.0 0.1 10.0 10.0 14 Bug Screen 0.76 15 Bug Screen 0.76 16 Bug Screen 0.76 17 Bug Screen 0.76• 18 Bug Screen 0.76 19 Bug Screen 70.76 20 Bug Screen 0.76 21 Bug Screen 0.76 22 Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 23 Bug Screen 0.76 24 Bug Screen 0.76 8.0 8.0 10.0 0.1 10.0 10.0 25 Bug Screen 0.76 Initiation Time& 07119/05 0813*57 Code:Run Run EnergyPro 3.1 By Energvsoft User Number: 3665 Job Number. Page:9 of 27 Comauter Method Summary (Part 3 of %) C -2R Lot #8 7/19/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Location Twe (sf) (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES Type F2 Length Factor Insulation R -Val. Depth Location / Comments Slab Perimeter 14 0.76 0.0 0 ZONE 1 Slab-ERh=ser 97 0.76 0.0 0 ZONE 1 Slab Perimeter 8 0.76 0.0 0 ZONE 2 Slab Perimeter 66 076 0.0 0 ZONE 2 Slah Perimeter 10 0_76 0.0 0 ZONE 3 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (air conditioner, Type (furnace, heat Efficiency and Location Duct Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 (Sleeping) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVA. -2 (Setback) Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVA -:;-3 (Living) Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment. Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 (Sleeping) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -2 (Setback) Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -3 (Living) WATER HEATING SYSTEMS Ratedl Tank Energy Facts 1 Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Reccvery Standby R -Value System Name Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. A.O. SMITH FPS -50-224 Small Gas Recirclrime+Temp 2_ 43.000 50 0.60 n/a n/a 1 For small gas storage (rated input <= 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. 'Computer Method Summary (Part 3 of 3) C -2R Lot #8' 7/19/2005 Project Title y Date THERMAL MASS FOR HIGH MASS DESIGN ` Area Thick. Heat Inside ' Location Type. (sq (in.) Cap. Cond. Form.3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 90 0.76 0.0 0 ZONE 3 HVAC SYSTEMS Heating Equipment , Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct ;Thermostat Location / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Locution / heat pump, evap. cooling). (SEER) (attic, etc,) R -Value Type Comments r - WATER HEATING SYSTEMS Rated' Tank Energy =act' Tank Insul. Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R=Value System Name' Type Type Syst. (Btu/hr) (gal) Efficiency Loss (%) Ext. 1 For small gas storage (rated input — 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Low. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS r%UII 1111U12 1U11 IIIIIC. VII I'ILPQ UO. IJ.;J1 IIUII VUUC. I I& I 100wat- EnergyPro 3.1 By Ener Soft User Number: 3665 Job Number. Pa e:11 of 27 Computer Method Summary (Addendum) C -2R Lot #8 7/19/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan FField The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeoing Areas. The HVAC System "HVAC -1 (Sleeping)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -2 (Setback)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. The HVAC System "HVAC -3 (Living)" must meet all CEC Criteria for a Zonally Controlled system serving only Living Areas. The HVAC System "HVAC -3 (Living)" includes credit for a Radiant Barrier installed per Section 8.13 of the Residential Manual. r HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a -•orm CF -6R. Plan Field The HVAC System "HVAC -1 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must -provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -1 (Sleeping)" is using reduced duct leakage to comply and must have diagnostic site testir•g of duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -2 (Setback)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must' provide verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -2 (Setback)" is using reduced duct leakage to comply and must have diagnostic site testing :)f duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. The HVAC System "HVAC -3 (Living)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS rater must provid(i. verification of the TXV, or measure the Refrigerant Charge and Airflow. The HVAC System "HVAC -3 (Living)" is using reduced duct leakage to comply and must have diagnostic site testing :)f duct leakage performed by a certified HERS Rater. The results of the diagnostic testing must be reported on a CF -6R Form. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:12 of 27 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Lot #8 DATE 7/19/2005 COMPONENT DESCRIPTION DESCRIPTION 0.010 OUTSIDE SURFACE AIR FILM 1 stucco ? Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME W-1 Wall .21.2x6.16 0.31 7 •0.37 s 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check one) Wall. LU W 0 W Ceiling / Roof 05 FRAMING MATERIAL Wow p FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" O.C. Wall) 10% (16" o.c. Floor/Cell.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) ❑ ❑ ❑ © ❑ El El El DESCRIPTION 0.010 OUTSIDE SURFACE AIR FILM 1 stucco ? Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 •0.37 s 2.60 9 0.68 INSIDE SURFACE AIR FILM ❑ ❑ ❑ © ❑ El El El 0.875 0.010 ; 0.375 5.500 0.625 0.175 0.060 0.060 0.465 SUBTOTA Rc, R R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0. 1751 0.175 0.060 0.060 0.465 0.465 21.000 5.445 0.5621 0.562 0.31 2.63 •0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.11 7.56 *HEAT CAPACITY (Optional) WALL' WEIGHT (Ibs/sf SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0433 X 0.85 ] 8.46 0.20 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 •0.37 0.98 2.60 0.26 0.68 1 G $ TOTAL HC 3 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 0.85 ] + [ 0.1323 X L 0.15 1 / Rc 1 - (Fr% / 100) 1 / Rf Fr% 1100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:13 of V PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lot #8 7/19/200 COMPONENT, DESCRIPTION d SUBTOTAL :a R -VALUE DESCRIPTION FRAMING ASSEMBLY NAME . ASSEMBLY W-2 Wall .21.2x6.16 Floor 1 Gypsum or Plaster Board '? Insulation,,Mineral Fiber, R-21 3 TYPE (check one) X Wall 0.98 5 Lu W ASSEMBLY U -VALUE Ceiling /Roof . 8 NFRAMING MATERIAL Wood INSIDE SURFACE AIR FILM 22.98 7.42 FRAMING % 15% Framing % 7 $ TOTAL HC 2.3 15% (16" o.c. Wallj 12% (24" o.c. Wall) 10% (16" o.c. Floor/CeiIJ SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Cell.) d SUBTOTAL :a R -VALUE DESCRIPTION FRAMING OUTSIDE SURFACE AIR FILM ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 Gypsum or Plaster Board '? Insulation,,Mineral Fiber, R-21 3 Gypsum or Plaster Board 4 0.98 5 0.26 6 ASSEMBLY U -VALUE 7 8 9 0.680 INSIDE SURFACE AIR FILM d SUBTOTAL :a R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.562. 0.562 21.000 5.445 0.562 0.562 0.37 0.98 2.60 0.26 0.68 ASSEMBLY U -VALUE 0.680 0.680 22.98 7.42 Rc Rf a EB 'HEAT CAPACITY (Optional) WALL WEIGHT (lbs/sf SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0435 X 0.85 ] 2.60 0.26 0.68 2.63 0.37 0.98 2.60 0.26 0.68 ASSEMBLY U -VALUE 7 $ TOTAL HC 2.3 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0435 X 0.85 ] + [ 0.13481 X 1 0.15.= 0.057 1 / Rc 1 - (Fr% 1100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE I � COMMENTS EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:14 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #8 7/19/2005 SYSTEM NAME FLOOR AREA HVAC -1 (Sleeping) 1,400 ENGINEERING CHECKS SYSTEM LOAD Number of Systems 1 COIL COOLING PEAK COIL HTG. PEAK Heating System CFM Sensible Latent CFM Sensible Output per System 89,400 Total Room Loads 1,506 29,365 3,942 517 21,231 Total Output (Btuh) 89,400 Return Vented Lighting 0 Output (Btuh/sgft) 63.9 Return Air Ducts 1,468 1,062 Cooling System Return Fan 0 0 Output per System 58,500 Ventilation 105 4,015 2,218 105 5,159 Total Output (Btuh) 58,500 Supply Fan 0 0 Total Output (Tons) 4.9 Supply Air Ducts 1,468 1,062 Total Output (Btuh/sgft) 41.8 TOTAL SYSTEM LOAD 36 317 6,160 28,513 Total Output (sgftrron) 287.2 Air System HVAC EQUIPMENT SELECTION CFM per System 2,000 HS26-060/G40UH60C-110 (5) 45,956 6,387 89,400 Airflow (cfm) 2,000 Airflow (cfm/sgft) 1.43 Airflow (cfm/Ton) 410.3 Outside Air (%) 5.2 Total Adjusted System Output 45,956 6,387 89,400 (Adjusted for Peak Design Conditions) 'Outside Air (cfm/sqft) 0.08 TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Note: values above given at ARI conditions EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 OF 67.10F 108.5 of 108.5 OF Su I PP Y AirOutside Air rlrr Um! 105 cfm 45 o 108.0 F Heating Coil Supply Fan 2000 cfm ROOMS 70.0 OF 69.5 of Return Air Ducts I DOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1/80.30F 80.5 / 66.1 of 59.3 / 57.9 of 59.3 / 57.9 OF =s Supply Air Ducts Outside Air0 105 cfm Cooling Coil Supply Fan 59.9 / 58.1 of 2000 cfm ROOMS 49-8% R.H. of 78.0 / 65.0 OF 78.7 / 65.2 Return Air Ducts EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 15 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #8 7/19/2005 SYSTEM NAME FLOOR AREA HVAC -2 Setback 1,354 Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensiblel Latent CFM I Sensible 1,274 25,138 3,978 424 , 17,519 0 1,257 876 0 0 102 3,894 2,164 102 4,998 0 0 1,257 876 31,546F76 142 7 24,2691 HS26-060/G40UH60C-110 (5) 45,881 6,369 89,400 Total Adjusted System Output 45,881 6,369 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 67.3 of 108.7 of 108.7 of 0 Supply Air Ducts Outside Air 102 cfm 108.3 of Heating Coil Supply Fan 2000 cfm ROOMS 70.0 of 69.6 of I Retum Air Ducts COOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak 114.1/80.30F 80.4 / 66.0 of 59.1 / 57.7 of 59.1 / 57.7 of ' Supply Air Ducts Outside Air O" 102 cfmF Cooling Coil Supply Fan 59.7 / 58.0 0 2000 cfm 49.6% R.H. ROOMS 78.6/65.1 of 78.0 64.9 OF "I C A:� EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 16 of 27 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #8 7/.19/2005 SYSTEM NAME FLOOR AREA HVAC-3(Living) 1,150 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 89,400 Total Output (Btuh) 89,400 Output (Btuh/sgft) 77.7 Cooling System Output per System 58,500 Total Output (Btuh) 58,500 Total Output (Tons) 4.9 Total Output (Btuh/sqft) 50.9 Total Output (sgftrron) 235.9 Air System CFM per System 2,000 Airflow (cfm) 2,000 Airflow (cfm/sqft) 1.74 Airflow (cfm/Ton) 410.3 Outside Air (%) 4.3 Outside Air (cfm/sgft) 0.08 Note: values above given at ARI conditions Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM I Sensible LEtent CFM I Sensible 1,736 34,434 3,439 658 27,145 0 1,722 1,357 0 0 86 3,287 1,914 86 4,225 0 0 1,722 1,357 41,165 5 353 34,084 HS26-060/G40UH60C-110 (5) 46,397 5,584 89,400 Total Adjusted System Output 46,397 5,584 89,400 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Arg 2 pm Jan 12 am EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak 24.0 of 67.4 of 108.8 of 108.8 of 310 O .. K.. Supply Ai . r Ducts Outside Z 86 cfm of 69.4 of Heating Coil Supply Fan 108'2 2000 cfm ROOMS 1 70.0 of 1% Return Air Ducts `{ )COOLING SYSTEM PSYCHROMETRICS (Airstream Temperatures at Time of Cooling Peak) I 114.1 / 80.3 of 80.3 / 65.7 of 58.8 / 57.4 of 58.8 / 57.4 of 310 Su iply Air Ducts Outside Air ' 86 cfm Cooling Coil Supply Fan 59.6 / 57.7 of 2000 cfm 4F-8% R.H. ROOMS 78.8164.9 of 78.0 / 64.6 of o..a...., n:_ n..,.a.. E I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:17 of 27 1 ROOM LOAD SUMMARY PROJECT NAME Lot #8 DATE 7/19/2005 SYSTEM NAME HVAC -1 Slee in FLOOR AREA 1,400 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 1 Master/Bed3 1 1,506 29,365 3,942 1,506 29,365 3,942 517 21,231 i PAGE TOTAL 1 1,506 29,365 3,942 517 21,231 TOTAL 1 1,506 29,365 3,942 517 21,231 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 18 of 27 ROOM LOAD SUMMARY PROJECT NAME Lot #8 DATE 7/19/2005 SYSTEM NAME HVAC -2 Setback FLOOR AREA 1,354 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING P=AK COIL,HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE -ATENT CFM SENSIBLE ZONE 2 KITCH/DINNIN/BED2 1 1,274 25,138 3,978 1,274 25,138 3,978 424 17,519 PAGE TOTAL 1,274 25,138 ` 3,978 424 17,519 TOTAL 1 1,274 25,138 3,978 424 17,519 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 19 of 27 IROOM LOAD SUMMARY I PROJECT NAME Lot #8 DATE 7/19/2005 SYSTEM NAME HVAC-3(Living) FLOOR AREA 1,150 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING PEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE ZONE 3 GREAT ROOM 1 1,736 34,434 3,439 1,736 34,434 3,439 658 27,145 PAGE TOTAL 1,736 F 34,434 3,439 658 277145 TOTAL 1,736 34,434 3,439 658 27,145 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:26 of 27 ROOM HEATING PEAK LOADS Project Title Date Lot #8 7/19/2005 Room Information Design Conditions Room Name Master/Bed3 Time of Peak Jan 12 am Floor Area 1,400 Outdoor Dry Bulb Temperature 24 OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value ,'�,T OF Btu/hr Items shown with an asterisk ('),denote conduction through an interior surface to another room. Page Total: 15,206 Infiltration: �chedue0 X Air Sensible x Area Calling X CallingHeghtX ACH50 /6] X 6T 46 = 6025 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,231 EnergyPro 3.1 By EnergySoft User Number. 3665 1 Job Number. Page: 21 of 27 1400.0 X X X X x X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 X X X x x X X x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1,803 847.2 0.0566 46.0 2,207 125.0 0.0572 46.0 329 96.8 0.5500 46.0 2,449 23.0 0.4000 46.0 423 80.0 0.8000 46.0 2,944 perimeter = 111.0 45.5 5,050 { Items shown with an asterisk ('),denote conduction through an interior surface to another room. Page Total: 15,206 Infiltration: �chedue0 X Air Sensible x Area Calling X CallingHeghtX ACH50 /6] X 6T 46 = 6025 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 21,231 EnergyPro 3.1 By EnergySoft User Number. 3665 1 Job Number. Page: 21 of 27 ROOM HEATING PEAK LOADS Project Title Date Lot #8 7/19/2005 Room Information Desi n Conditions Room Name KITCH/DINNIN/BED2 Time Of Peak Jan 12 am Floor Area 1,354 Outdoor Dry Bulb Temperature 24 of Indoor Dry Bulb Temperature 70°F Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 11 299 Infiltration:1.00 x 1.080 x 1 354 x 11.10 x 0.50 / 60] x 46 = 6 220 Schedule Air Sensible Area Ceiling Height ACH In Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,519 I. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 22 of 27 1354.0 X X X X x x x X X x X X x X X X x X X X X X X X X X X X x X X X X X X X x X X 0.0280 x X X X X X X x x' X X X X x X X X x X X x x X X x X X X x X X x X X X X X x X 46.0 = = = = = = = = _ = = = = = = 1,744 273.7 0.0572 46.0 720 21.3 0.3872 46.0 379 366.8 0.0566 46.0 955 48.8 1.1900 46.0 2,671 39.0 0.4000 46.0 718 29.4 0.5500 46.0 744 perimeter = 74.0 45.5 3,367 Items shown with an asterisk ('r) denote conduction through an interior surface to another room. Page Total: 11 299 Infiltration:1.00 x 1.080 x 1 354 x 11.10 x 0.50 / 60] x 46 = 6 220 Schedule Air Sensible Area Ceiling Height ACH In Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 17,519 I. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 22 of 27 ROOM HEATING PEAK LOADS ,, Project Title Date Lot #8 7/19/2005 Room Information Design Conditions Room Name GREAT ROOM Time of Peak Jan 12 am Floor Area 1,150 Outdoor Dry Bulb Temperature 24OF Indoor Dry Bulb Temperature 70 OF Conduction Area U -Value 12�,T of Btu/hr Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. - Page Total: 21 720 Infiltration: II 1.001xL 1.0801X 1 150 x 11.40 x 0.50 / 60] x 46 = 5 425 chedule Air Sensible Area Ceiling Height ACH In Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,145 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 23 of 27 1150.0 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 0.0280 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 46.0 = = = = = = = = = = = = = = = = = = = = = = = = =. = = = = = = = = = = = = = = 1,481 698.2 0.0566 46.0 1,819 312.0 0.8000 46.0 11,482 129.8 0.4000 46.0 2,388 perimeter= 100.0 45.5 4.550 Items shown with an asterisk ('rr) denote conduction through an interior surface to another room. - Page Total: 21 720 Infiltration: II 1.001xL 1.0801X 1 150 x 11.40 x 0.50 / 60] x 46 = 5 425 chedule Air Sensible Area Ceiling Height ACH In Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 27,145 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 23 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #8 7/19/2005 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: Master/Bed3 780F 1150F 37°F Conduction Area U -Value DETD' Btu/hr X X X X X X X x X X (East) 56.0 = 2,196 X FxdGlsWdw (5) 35.6 = 1,708 X (South) 35.6 = 255 X 8.0 37.0 = 1970 X 29.4 37.0 = 340 X 3.0 37.0 = 2,368 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 8 836 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 2 CsmntWdws 1 (East) CsmntWdw (2) CsmntWdw 3 (East) (East) 2 CsmntWdws 4 East FxdGlsWdw (5) (East) 2 CsmntWdw 6 (East) FrnchDr 7 (South) FrnchDr 8 South 4 FxdGlsWdws 9 (South) 8.0 73 ( 0.0 X1 x x x X X x X X x + 1 + 1 + 1 + 1 + 1 + 1 + 1 + 1 + + 29.4 X X x x x x x X x x 73 )X ) x ) x x K K K )K 0.334 = = = = = = = = = = 717 ( 0.0 8.0 73 0.334 195 ( 0.0 8.0 73 0.334 195 ( 0.0 29.4 73)-.( 0.334 717 ( 0.0 3.0 73) 0.390 85 ( 0.0 22.0 73)-K 0.334 536 ( 0.0 40.0 32) 0.657 841 ( 0.0 40.0 32) 0.657 841 ( 0.0 20.0 3) 0.390 249 ( F Sched. Page Total 4 376 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,400 X 0.500 Watts/sgft X 3.4d BtehlVVatt = 2,389 Occupants 1.00 X 1,400 X 250 Btuh/occ. / 200 sq-t/occ. = 1,750 Receptacle 1.00 x 1,40 x 1.500 Watts/sgft X 3.413 Btah/Waft = 7,167 Process 1.00 X 1,40 X 0.000 Watts/sgft x 3.41 Btuh/V11att = 0 Infiltration: x Air Sensible � x Area x Ceiling� X ACH / 60] Z Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 29,365 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 400 X 200 Btuh/ocC. / 20 sgft/occ. = 1 400 Receptacle 1.00 x 1 400 X 0.000 Watts/sgft x 3.41 BtuhNVatt = o Process 1.00 X 400 X 0.000 Watts/sgft x 3.41 Btuh/Watt = 0 Infiltration: 1.00 X 4 840 x 1 40 X 10.40 X 0.50 / 60] 1 0,00433 = 2 542 -Schedule Air Latent Area Ceiling Height ACH IJV Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,942 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 24 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #8 7/19/2005 Project Title Date Room Name KITCH/DINNIN/BED2 Design Indoor Dry Bulb Temperature: 780F Design Outdoor Dry Bulb Temperature: 1150 F Design Temperature Difference: 370F Conduction Area U -Value DETDBtu/hr R-38 Roof R.38.2x14.16 -2 Wall .21.2x6.16 Solid Wood Door -1 Wall .21.2x6.16 Default Single Metal Tinted Fleetwood Glazing Fleetwood Glazing X X X X X X X 56.0 = = = = = = = 2123 35.6 557 35.6 294 35.6 739 37.0 2,149 37.01 577 1 37.01 1 598 X X 1. Design Equivalent Temperature Difference (DETD) Page Total 7 038 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr FxdSiteBlt 10 (East) ( ^(South) 0.0 X 1 + 19.5 x 73)= 0.757 = 1 X8 FxdS*tpRlt (11) ( 0.0 x 1 + 29.3 X 32 ) z 0.757 = 710 FxdGlsWdw 12 (South) ( 39.0 X 1 + 0.0 x 32) x 0.390 = 228 2 CsmntWdws 13 (West) ( 29.4 X ill 0.0 X 73) x 0.334 = 147 ( x + x )x = ( x + x )x = ( x + x )x = ( x + X )x = ( X + X )x _ Sched. Page Total 2 163 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 X 1,354 x 0.500 Watts/sqft x 3.412:BtuhNVatt — 2.311 Occupants 1.00 X 1,354 X 250 Btuh/occ. / 200 sgtt/occ. = 1,692 Receptacle 1.00 x 1,354 x 1.500 Watts/sqft X 3.413 Btuh/Watt = 6,932 Process 1.00 X 1354 X 0.000 Watts/sqft x 3.412 Btuh/Waft = 0 Infiltration: �on� x Air Sensible � X Area J x Ceiling � X ACH / 60] � = 5.003 Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 25,138 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1,354 X 200 Btuh/OCC. / 200 sgrt/occ. = 1 354 Receptacle 1.00 x 1,354 X 0.000 Watts/sgft X 3 41 Btuh/Watt = 0 Process 1.00 x 1,354 X 0.000 Watts/sgft X 3.4I BtuhlWatt = 0 Infiltration: �chedulle ool X Air Latent X Area 354 X Ceiling Height x ACH 50 / 60] l0W0433 = 2 624 11 Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,978 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 25 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #8 7/19/2005 Project Title Date Room Name GREAT ROOM Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 780E 115°F 37°F Conduction Area U -Value IDETD 1 Btu/hr X X X X X X X X X X X 56.0 = = = = = = = = = 1803 35.6 1,407 37.0 9,235 37.0 1,921 4 FxdGlsWdws 19 (South) FxdGlsWdw 20 (South) FxdGlsWdw 21 est 3 FmchDr 22 3 FxdGlsWdws 23 (West) est 0.657 394 1. Design Equivalent Temperature Difference (DETD) Page Total 14 367 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 3 FrnchDrs 14 (North) (3) FxdGic_Wdwc_ ( (North) FrnchDr 16 North FrnchDr 17 (South) FrnchDr (18) (South) 4 FxdGlsWdws 19 (South) FxdGlsWdw 20 (South) FxdGlsWdw 21 est 3 FmchDr 22 3 FxdGlsWdws 23 (West) est ( 0.0 X x X x1 x x x x X x 1 + 1 + A + + 1 + 1 + 1 + 1 + 1 + 1 + 64.0 X X X x X x x x X X 15 )-C ):K K K K IK K 0.657 = = = = = = = = = = 631 ( 0.0 16.0 15 0.390 94 ( 0.0 40.0 15),c 0.657 394 ( 0.0 40.0 32) 0.65 841 ( 0.0 40.0 32) 0.657 841 ( 0.0 20.0 32) 0.390 249 ( 0.0 39.0 32) 0.390 486 (0.0 22.8 73) 0.390 648 ( 63.2 0.8 73)x 0.65 661 ( 0.0 16.0 73)x 0.390 455 Sched. Page Total 5 300 Internal Gain Frac. Area Heat Gain Btu/hr Lights 1.00 X 1,150 X 0.500 Watts/sgft x 3.41 BtohlWaft = 1.962 Occupants 1.00 X 1,150 X 250 Btuh/occ. / 200 sci t/occ. = 1,438 Receptacle 1.00 x 1,150 x 1.500 Watts/sqft x 3.413 Btuh/Waft = 5,887 Process 1.00 x 'r- 1,1�50_x_� 0.00 Watts/sqft x 3.41�BtuhMaft = 00�I Infiltration: ��� x Air Sensible� x t1�1�W x Ceiling x ACH 50 / 60] I J nT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,434 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 X 1 150 x 200 Btuh/occ. / 200 sgft/occ. = 1 50 Receptacle 1.00 X 1 150 X 0.000 Watts/sgft x 3.41 Btuh/Waft = 0 Process (� 1.00 x 1 150 x 0.000 Wafts/sqft X 3.41 Bt)uh[Watt = o Infiltration: I 1.00 x 4,8401 x 1 15 x 11.40 x 0.50 / 60] a00433 = 2 289 "--schedule Air Latent Area Ceiling Height ACH IJV Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,439 EnergyPro 3:1 By EnergySoft User Number. 3665 -Job Number. Page: 26 of 27 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #8 71191200-15 Project Title Date Room Name Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: GREAT ROOM 780F 115°F 370E Conduction Area U -Value DETD' Btu/hr X X X X X X X x X 1. Design Equivalent Temperature Difference (DETD) r Page Total Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF Area SGF SC Btu/hr 3 FrnchDrs 24 (West) ( 63.2 X 1 + 0.8 x 73)_C 0.657 = 661 (West) ( 0.0 x 1 + 16.0 X 73).0 0.390 = 455 ( x + x ( x + x )x = ( x + x )K = ( x + x )K = ( x + x )K ( x + x )K ( x + x I )K = Sched. Page Total 1 116 Internal Gain Frac. Area Heat Gain Btu/hr Li hts 1.00 x 1,150 x 0.500 Watts/sgft x 3.41 Bt■h/Waft = 1,962 Occupants 1.00 X 1,150 X 250 Btuh/OCC. / 200 sq-V6cc. = 1,438 Receptacle 1.00 x 1,150 x 1.500 Watts/sgft X 3.413 Btah/Waft = 5,887 Process ' r 1.00 x 1,150 x 0.000 Wafts/sgft x 3.41 BtuhMatt = 0 Infiltration: I ch� x Air Sensible � x Area . 1;150 x Ceiling � x ACH / 60] Z Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 34,434 Sched. Latent Gain Frac. Area Heat Gain - Btu/hr Occupants 1.00 X 1 50 x 2001 Btuh/OCC. / 200 Sgft/oCC. = 1 150 Receptacle 1.00 x 1 150 x 0.000 Watts/sgft x 3.41 Bt-llh/Watt = 0 Process r 1.00 x 1 150 x 0,00 Watts/sgft x 3.41 BtjWlWatt = 0 Infiltration: I 1.0o x 4840 x 1 15 x 11.40 x 0.50 / 60] 1 0.00433 = 2 289 —Schedule Air Latent Area Ceiling Height ACH �ry Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 3,439 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. - Page: 27 of 27 TITLE 24 REPORT Title. 24 Report for: Lot #8 (Guest House) 57-270 Peninsula Lane @ PGA West La Quinta, CA 92253 Project Designer: Southern Hills Development, Inc. 78-150 Calle Tampico, Sui#e #101 La Quinta, CA 92253 (760) 771-3497 Report Prepared. By: CJ Mcfadden BREEZE AIR CONDITIONING 75-145 ST. CHARLES PLACE PALM DESERT, CA 92211 (760) 346-0855 Job Number: Date: 7/19/2005 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. Thi3 program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Enemy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883=5900. EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 TABLE OF CONTENTS Cover Page Table of -Contents 2 Form CF -1 R Certificate.of Compliance 3 Form MF -1R Mandatory Measures Checklist 6 Form C -2R Computer Method Summary 8 Form ENV -3 Proposed Construction Assembly 12 HVAC System Heating and Cooling Loads Summary 14 .Room Load.,Summary 15 Room Heating Peak Loads 16 Room Cooling Peak Loads 17 EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 :r EnergyPro 3.1 By EnergySoft Job Number. User Number. 3665 Certificate of Compliance: Residential (Part 1 of 2) CF -1 R Lot #8 (Guest House) .7/19/2005 Project Title Date 57-270 Peninsula Lane a PGA West La Quinta. Project Address Building.Permit # BREEZE AIR CONDITIONING (760) 346-0855 Plan Check/ Date Documentation Author Telephone Computer Performance 15 Field Check / Date Compliance Method (Package or Computer) Climate Zone Enforcement Agency Use Only GENERAL INFORMATION Total Conditioned Floor Area: 634 ft2 Average Ceiling Height: 10.0 ft Total Conditioned Slab Area: 634 ft2 Building Type: Area (check one or more) Fenestration X❑ Single Family Detached ❑ Addition ❑ Single Family Attached ❑ Existing Building ❑ Multi -Family ❑ Existing Plus Addition Front Orientation: All Four Orientations Floor Construction Type: ® Slab Floor Number of Dwelling Units: 1.00 Number of Stories: 1 ❑ Raised Floor FtNt5TKATIUN 5hadin Devices Type Orientation Area Const. Fenestration Component Frame Assembly Location/Commen:s Type Type U -Value (attic, garage, typical. etc.) R-38 Roof (R.38.2x14.16) Wood 0.028 Exterior Roof W-1 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall W-2 Wall (W.21.2x6.16) Wood 0.057 Exterior Wall Slab On Grade n/a 0.756 . Exposed Slab w/R-0.0 Perimeter Insulation Slab On Grade n/a 0.756 Covered Slab w/R-0.0 Perimeter Insulation FtNt5TKATIUN 5hadin Devices Type Orientation Area Fenestration Exterior Overhang Side Fins SF U -Factor SHGC Shading Yes / No Yes / No Front 24.0 0.80 0.59 Bug Screen ❑ Q ❑ 0 Front 58.8 0.55 0.30 Bug Screen ❑ Q ❑ X❑ Rear 36.0 0.55 0.30 Bug Screen ❑ x❑ ❑ x❑ Right 18.0 0.40 0.35 Bug Screen ❑ x❑ ❑X❑. El -E] ❑ ❑ El El El 1:1 El El El 1-1 ❑❑ ❑❑ El El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Run Initiation Time: 07/19/05 08:13:44 Run Code: 1121786024 Ener Pro 3.1 By Ener Soft User Number: 3665 - Job Number: Pa e:3 of 17 Certificate of Compliance: Residential (Part 2 of 2) CFA R Lot #8 (Guest House) 7/19/2005 Project Title Date HVAC SYSTEMS Note: Input Hydronic or Combined Hydronic data under Water Heating Systems, except Design Heating Load. Distribution Heating Equipment Minimum Type and Duct or Type (furnace, heat Efficiency Location Piping Thermostat Location / pump, etc.) (AFUE/HSPF) (ducts, attic, etc.) R -Value Type Comments Central Furnnna 80% AFUE Ducts in Attic 4.2 Setback HVACA (Sleeping) Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc.) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 42 Sethack HVAC' -1 (Slee ing) WATER HEATING SYSTEMS Rated 1 Tank Energy Fadi 1 External Water Heater Water Heater Distribution # in Input . Cap. or Recovery Standby Tank Insul. System Name Type Type Syst. Btu/hr (gal) Efficiency . Loss (%) R -Value Standard Gas 50 gal or Less Small Gas Recircfrime+Temp 1 40.000 50 0.53 n/a 12 1 For small gas storage (rated inputs of less than or equal to 75,000 Btu/hr), electric resistance and heat pump water heaters, lis. energy factor. For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input, Recovery Efficiency and Stanrby Loss. For instantaneous gas water heaters, list Rated Input and Recovery Efficiency. REMARKS GUEST HOUSE WILL UTILIZE WATER HEATING FROM MAIN RESIDENCE. A STANDARD 50 GAL. WATER HEATER IS BEING USED AS A PLACE HOLDER AND DOES NOT ACHEIVE ANY CREDITS IN THIS CALCULATION. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with —itle 24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. The undersigned recognize that compliance using duct sealing and TXV's requireE installer testing and certification and field verification by an approved HERS rater. Designer or Owner (per Business & Professions Code) Documentation Author Name: Name: CJ Mcfadden Title/Firm: Southern Hills Development, Inc. Title/Firm: BREEZE AIR CONDITIO DING Address: 78-150 Calle Tampico, Suite #101 Address: 75-145 ST. CHARLES PLACE La Quinta, CA 92253 PALM DESERT, CA 922-.1 Telephone: (760) 771-3497 Telephone: (760) 346-0855 Lic: #: (signature) (date) (signature) (da ) Enforcement Agency Name: Title/Firm: Address: Telephone: I EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paae:4 of 17 1 Certificate of Compliance: Residential (Addendum) CF -1 R Lot #8 (Guest House) 7/19/2005 Project Title Date Special features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 Extemcl Blanket. The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeping Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC approved HERS provider. The HERS rater must document the field verification and diagnostic testing of these measures on a form CF -6R. Plan I Field The HVAC System "HVAC -1 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS -ater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. r Run Initiation Time: 07/19/05 08:13:44 Run Code: 1121786024 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:5 of 17 Run Initiation Time: 07/19/05 08:13:44 Run Code: 1121786024 EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page:5 of 17 Mandatory Measures Checklist: Residential (Page 1 of 2) MFA R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approa:h used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Instructions: Check or initial applicable boxes or enter N/A if not applicable. DESIGNER ENFORCEMENT Building Envelope Measures a `§ 150(a): Minimum R-19 ceiling insulation. ❑ § 150(b): Loose fill insulation manufacturer's labeled R -Value. § 150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -value in metal frame walls (does ❑! X not apply to exterior mass walls). ❑ ' § 150(d): Minimum R-13 raised floor insulation in framed Floors or equivalent. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%, water vapor transmission rate no ❑ greater than 2.0 permfinch. a§118: Insulation specified or installed meets insulation quality standards. Indicate type and form. ® §116-17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.. 2. Fenestration products (except field fabricated) have label with certified U -Factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. ❑ § 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. § 150(f): Special infiltration barrier installed to comply with Section 151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs. 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures ❑X §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. ❑ § 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ❑ § 150(i): Setback thermostat on all applicable heating and/or cooling systems. ❑X §1506): Pipe and Tank Insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R4 or greater) 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined intemal/extemal insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water systems. 5. Cooling system piping below 55 degrees F. insulated. 6. Piping insulating between heating source and indirect hot water tank. EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page:6 of 17 Mandatory Measures Checklist: Residential (Page 2 of 2) MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. :• DESCRIPTION Instructions: Check or initial applicable boxes or enter NIA if not applicable. DESIGNER ENFORCEMENT Space Conditioning, Water Heating and Plumbing System Measures: (continued) X❑ I 150(m): . Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the 1998 CMC Sections 601, 603, 604 and Standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause. reductions in the cross-sectional area of the ducts. 3. Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes unless such a tape is used in combination with mastic and drawbands. ~ 4. Exhaust fan systems have back draft or automatic dampers. 5. Gravity ventilation systems serving conditioned space have eitherautomatic or readily accessible, manually operated dampers. 6. Protection of Insulation. Insulation shall be protected from damage, Including that due to sunlight, moisture, equipment maintenance, and wind but not limited to the following: Insulation exposed to weather shall be suitable for outdoor service e.g., protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material. ❑ § 114: Pool and Spa Heating Systems and Equipment 1. Certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating, and no pilot. 2. System is installed with at least 36" of pipe between filter and heater for future solar, cover for outdoor pools or spas. a. At least 36" of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) ❑ §118 (f): Cool Roof material meet specified criteria Lighting Measures ® § 150(k)1: Luminaires for general lighting in kitchens shall have lamps with an efficacy 40 lumens/watt or greater for general lighting in kitchens. This general lighting shall be controlled by a switch on a readily accessible lighting control panel at an entrance to the kitchen. a§150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40 lumens/watt or greater switched, at the entrance to the room or one of the alternative to this requirement allowed In Section 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. 3.1 By EnergySoft User Number. 3665 Job Number. Page:? of 17 Computer Method Summary (Part 1 of 3) C -2R Lot #8 (Guest House) 7/19/2005 Project Title Date 57-270 Peninsula Lane @ PGA West La Quinta Project Address -Building Permit # BREEZE AIR CONDITIONING (760) 346-855 Documentation Author Telephone Plan Check/Date Computer Performance 15 Field Check/Date Compliance Method (Package or Computer) Cimate Zone Source Energy Standard Use (kBtu/sf-yr) Design Space Heating 4.13 Facing North Margin Facing East Margin _0 Wall 180 0.057 90 90 Wall 45 0.057 90 90 wall 229 0.057 180 90 Facing South Margin ❑ ❑ ❑ Facing West Margin 8.10 -3.97 7.47 -3.34 6.30 -2.1'7 7.36 -3.23 Space Cooling 54.42 34.30 20.11 40.95 13.47 37.10 17.31 ❑ 40.32 14.10 Domestic Hot Water 30.67 1 29.60 1.07 ❑ 29.60 1.07 29.60 1.07 29.60 1.07 1 72.00 17.22 78.01 11.211 73.00 16.22 1 7.28 11.94 Totals 89.22 This C -2R describes the front facing North occurrence of a four cardinal orientation analysis. Features are identical in all orientations. Total Conditioned Floor Area: 634 ft Building Type: Single Fam Detached Floor Construction Type: ❑ Raised Floor 0 Slab Floor Building Front Orientation: All Four Orientations Total Fenestration Area: 21.6/0 Number of Dwelling Units: 1.00 Total Conditioned Volume: 6,340 ft 3 Number of Stories: 1 Total Conditioned Slab Area: 634 ft2 BUILDING ZONE INFORMATION # of Thermostat Vent Zone Name Floor Area Volume Units Zone Type Type Hgt. Area HVAC'-1_(Sleeping) 834 S San X00_ S1Peping �Slr__p_inaStat 2 _n/2 OPAQUE SURFACES Act. Type Area U -Val. Azm. Tilt Solar Gains Y / N Form 3 Reference Location / Comments Ronf 634 0.028 345 0 all 222 0.057 go ®❑ R-38 Raof (R I 2x14 1R) HVAC -1 W-1 Wall (W 21 2x6 16) HVAC _0 Wall 180 0.057 90 90 Wall 45 0.057 90 90 wall 229 0.057 180 90 ❑ ❑ ❑ W-1 Wall (W 21 9Y6 16) HVAC -1 W-7 Wall (V1/ 21 2x6.16) HVAC -1 W-1 Wall (W 21 2xR 1R) HVAC -1 Wall 45 0.057 180 90 Wall 207 0.057 270 90❑ ❑ ❑ 1 2x9 19) HVAC -1 _ W-1 Wall (W 21 2x6 1R) HVAC -1 ❑ ❑ ❑ ❑ ❑❑❑ ❑❑❑ ❑❑ Run Initiation Time: 07/19/05 08.13.44 Run Code: 1121786024 3.1 By EnergySoft User Number: 3665 Page:8 of 17 Computer Method Summary (Par12 of 3) C -2R Lot #8 (Guest House) 7/19/2005 Project Title Date FENESTRATION SURFACES U- Act. Glazing Type Location/ # Type Area Factor SHGC Azm. Tilt Comments J_ Window Front (North) 24.0 0800 0.59 0_ qn Fleetwood Glazing HVAC -1 2 • Window Front (North) 29.4 0.550 0.30 0 90 Fleetwood Glazing HVAC -1 3 Window Front (North) 29.4 0.550 0.30 0 90 Fleetwood Glazing HVAC -1 4 Window Rear (South) 6.0 0.550 0.30 180 90 Fleetwood Glazing HVAC -1 5 Window Rear (South) 30.0 0.550 0.30 180 90 Fleetwood Glazing HVAC -1 6 Window Right (West) 18.0 0.400 0.35 270 90 Fleetwood Glazing HVAC -1 INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hgt. LExt. RExt. Dist. Len. Hgt. Dist. Len. Hgt. 1 Bug Screen 0.76 2 Bug Screen 0.76 3 Bug Screen 0.76 4 Bug Screen 0.76 5 Bug Screen 0.76 — 6 Bug Screen 0.76 — EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:9 of 17 1 Computer Method Summary (Part 3 of 3) C -2R Lot #8 (Guest House) 7/19/2005 Project Title Date THERMAL MASS FOR HIGH MASS DESIGN Area Thick. Heat Inside Locatton Type (so (in.) Cap. Cond. Form 3 Reference R -Val. Comments PERIMETER LOSSES F2 Insulation Type Length Factor R -Val. Depth Location / Comments Slab Perimeter 11 0.76 0.0 0 HVAC -1 Slab Perimeter 05 0.76 0.0 0 HVAC -1 HVAC SYSTEMS Heating Equipment Minimum Distribution Type Type (furnace, heat Efficiency and Location Duct :Thermostat Locetion / pump, etc.) (AFUE/HSPF)(ducts/attic, etc.) R -Value Type Comments Central Furnace 80%AFUE Ducts in Attic 4.2 Setback HVAC -1 (Sleeping) Hydronic Piping Pipe Pipe Insul. System Name Length Diameter Thick. Cooling Equipment Minimum Duct Type (air conditioner, Efficiency Location Duct Thermostat Location / heat pump, evap. cooling) (SEER) (attic, etc,) R -Value Type Comments Split Air Conditioner 14.0 SEER Ducts in Attic 4.2 Setback HVAC -1 (Sleeping) WATER HEATING SYSTEMS Ratedl Tank Energy Fact! 1 Tank Insul; Water Heater Water Heater Distribution # in Input Cap. or Recovery Standby R -Value System Name, Type Type Syst. (Btu/hr) (gal) Efficierr-y Loss (%) Ext. Standard Gas 50 gal or. Less Small Gas Recirc/Time+Temp 1 40.000 50 0.53 n/a 12 1 For small gas storage (rated input <- 75000 Btu/hr), electric resistance and heat pump water heaters, list energy factor. For large gas storage water heaters (rated input > 75000 Btu/hr), list Rated Input, Recovery Efficiency and Standby Loss. For instantaneous gas water heaters, list Rated Input, and Recovery Efficiency. REMARKS 3UEST HOUSE WILL UTILIZE WATER HEATING FROM MAIN RESIDENCE. A STANDARD 50 GAL. WATER HEATER IS BEING USED AS A PLACE HOLDER AND DOES NOT ACHEIVE ANY CREDITS IN THIS CALCULATION. I _ � J Computer Method Summary. (Addendum) C -2R Lot #8 (Guest House) 7/19/2005 Project Title Date Special Features and Modeling Assumptions The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies 3asea on ine aaequacy or ine special jusuricauon ana oocumemarion suomittea. Plan Field The DHW System "Standard Gas 50 gal or Less" Energy Factor = 0.530. An EF below 0.58 requires an R-12 Externsl Blanket. The HVAC System "HVAC -1 (Sleeping)" must meet all CEC Criteria for a Zonally Controlled system serving only Sleeoinq Areas. HERS Required Verification These features must be confirmed and/or tested by a certified HERS rater under the supervision of a CEC aoDroved HERS provider. ine HhK5 rater must document the field verification and diagnostic testing of these measures on a fform CF -6R" plan Field The HVAC System "HVAC -1 (Sleeping)" includes Refrigerant Charge and Airflow Credit (or a TXV). A certified HERS pater must provide verification of the TXV, or measure the Refrigerant Charge and Airflow. a EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number. Page: 11 of 17 1 PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME DATE Lot #8 Guest House 7/19/2005 COMPONENT DESCRIPTION DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco ? Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 ASSEMBLY NAME W_1 Wall 21.2x6.16 0.31 7 0.37 8 2.60 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 23.11 TYPE (check (check one) Wall LU Ceiling /Roof 0 FRAMING MATERIAL Wood N p Z FRAMING % 15%o Framing /a 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY 7% (24" o.c. Floor/Ceil.) SUBTOTAI R -VALUE DESCRIPTION WOOD FRAME R -VALUE OUTSIDE SURFACE AIR FILM 1 Stucco ? Membrane, Vapor -Permeable Felt 3 Plywood 4 Insulation, Mineral Fiber, R-21 5 Gypsum or Plaster Board 6 0.31 7 0.37 8 2.60 9 0.68 INSIDE SURFACE AIR FILM SUBTOTAI R -VALUE CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170 0.170 0.175 0.175 0.060 0.060 0.465 0.465 21.0001 5.445 0.562 0.562 0.31 2.63 0.37 0.98 2.60 0.26 0.68 0.680 0.680 23.11 7.56 Rc KT U��u *HEAT CAPACITY (Optional) WALL WEIGHT (Ibs/sip SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0433 X 0.85 ] 8-46 0.20. 1.69 0.06 0.35 0.02 1.06 0.29 0.31 2.63 0.37 0.98 2.60 0.26 0.68 14.81 TOTAL HC 3 7 'NOTE: Weight and Specific Heat values for materials penetrated by wood framing include the effects of the framing members. [ 0.0433 X 0.85 ] + [ 0.1323 X F 0.15 = 0.057 1 / Rc 1 - (Fr% / 100) 1 / Rf _ Fr/100 / 100 ASSEMBLY U -VALUE EnergyPro 3.1 By EnergySoft User Number: 3665 Job Number: Page:12 of 17 . I PROPOSED CONSTRUCTION ASSEMBLY ENV -3 PROJECT NAME Lot #8 (Guest House DATE 7/19/20011 COMPONENT DESCRIPTION DESCRIPTION 5.500 OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board ?" Insulation, Mineral Fiber, R-21 3 Gypsum or'Plaster Board 4 0.37 5 ASSEMBLY NAME W_2 Wall 21.2x6.16 0.68 7 ASSEMBLY U -VALUE 8 ASSEMBLY Floor INSIDE SURFACE AIR FILM 0.680 22.98 TYPE (check one) X Wall W w W Ceiling / Ronf NFRAMING MATERIAL Wood O FRAMING % 15 % Framing % 15% (16" o.c. Wall) 12% (24" o.c. Wall) 10% (16" o.c. Floor/Ceil.) SKETCH OF ASSEMBLY ,, 7% (24" o.c. Floor/Ceil.) CONSTRUCTION COMPONENTS A n ❑ © ❑ El El El DESCRIPTION 5.500 OUTSIDE SURFACE AIR FILM 1 Gypsum or Plaster Board ?" Insulation, Mineral Fiber, R-21 3 Gypsum or'Plaster Board 4 0.37 5 ' 6 0.68 7 ASSEMBLY U -VALUE 8 9 INSIDE SURFACE AIR FILM ❑ © ❑ El El El 0.625 5.500 0.625 0.170 0.562 0.562 21.000 5.445 0.562 0.562 0.37 SUBTOTAL R -VALUE' CAVITY R -VALUE (Rc) WOOD FRAME R -VALUE 0.170" 0.170 0.562 0.562 21.000 5.445 0.562 0.562 0.37 .0.98 2.30 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE 0.680 0.680 22.98 7.42 Rc R . *HEAT CAPACITY (Optional) WALL WEIGHIT (lbs/sfi SPECIFIC HEAT (Btu/F-Ib) HC (A X B) (Btu/F-sf) [ 0.0435 X 0.85 2.50 0.26 0:68 2.33 0.37 .0.98 2.30 0.26 0.68 Fr% / 100 ASSEMBLY U -VALUE $ TOTAL HC 2.3 *NOTE: Weight and Specific Heat values for materials penetratedby wood framing include the effects of the framing members.' [ 0.0435 X 0.85 + r 0.1348 1 X L 0.15 = 0.057- 1 / Rc 1 - (Fr-/. / 100) 1 / Rf Fr% / 100 ASSEMBLY U -VALUE COMMENTS EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:13 of 17 HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY PROJECT NAME DATE Lot #8 Guest House 7/19/2005 SYSTEM NAME FLOOR AREA HVAC -1 (Sleeping) 634 ENGINEERING CHECKS 11SYSTEM LOAD Number of Systems 1 Heating System Output per System 54,100 Total Output (Btuh) 54,100 Output (Btuh/sqft) 85.3 Cooling System Output per System 36,000 Total Output (Btuh) 36,000 Total Output (Tons) 3.0 Total Output (Btuh/sgft) 56.8 Total Output (sgftrron) 211.3 Air System CFM per System 1,200 Airflow (cfm) 1,200 Airflow (cfm/sgft) 1.89 Airflow (cfm/Ton) 400.0 Outside Air (%) 4.0 ` Outside Air (cfm/sgft) 0.07 Note: values above given at ARI conditions 24.0 OF Outside Air 48 cfm R7 r of Total Room Loads Return Vented Lighting Return Air Ducts Return Fan Ventilation Supply Fan Supply Air Ducts TOTAL SYSTEM LOAD COIL COOLING PEAK COIL HTG. PEAK CFM Sensible Latent CFM Sensible 66 14,431 1,74 341 14,296 0 722 715 0 0 48 1,825 1,208 48 2,333 0 0 722 715 17,699 2,949 18 059 HS26-036/G40UH36A-70X (3) 29,453 1,993 54,100 Total Adjusted System Output 28,453 1,993 54,100 (Adjusted for Peak Design Conditions) TIME OF SYSTEM PEAK Aug 2 pm Jan 12 am Cream Temperatures at Time of Heating Peak) 109.4 OF 109.4 OF Supply Air Ducts 1089OF Heating Coil Supply Fan 1200 cfm ROOMS 69.4 of 70.0 °F Return Air Ducts I 14.1 / 80.3 of , Outside ' 48 cfm 78.6/63.9 of ROMETRICS (Airstream Temperatures at 80.0/64.60F M 57.2/55.80F Cooling Coil Supply Fa 1200 cfm 57.2 / 55.8 OF Supply Air Ducts Fan 57.8 / 56.0 of 4E.6% R.H. ROOMS 78.0 63.7 of h Return Air Ducts `S EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Paoe:14 of 17 1 JR00M LOAD SUMMARY PROJECT NAME Lot #8 Guest House DATE 7/19/2005 SYSTEM NAME HVAC -1 (Sleeping) FLOOR AREA 634 ROOM LOAD SUMMARY ROOM COOLING PEAK COIL COOLING FEAK COIL HTG. PEAK ZONE NAME ROOM NAME Mult. CFM SENSIBLE LATENT CFM SENSIBLE LATENT CFM SENSIBLE HVAC -1 HVAC -1 1 661 14,431 1,741 661 14,431 1,741 341 14,296 PAGE TOTAL TOTAL 1 6611 14,431 1,741 341 14,296 1 6611 14,431 - 1,741 341 14,296 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number: Page: 15 of 17 ROOM HEATING PEAK LOADS Project Title Date Lot #8 Guest House 7/19/2005 Room Information Desicin Conditions Room Name HVAC -1 Time of Peak Jan 12 am Floor Area 634 Outdoor Dry Bulb Temperature 24OF Indoor Dry Bulb Temperature 70.0 Conduction Area U -Value :LT of Btu/hr Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11,673 Infiltration:11.001 cheduex Air Sensible x Area Coiling X CoilingHeightx ACH50 /6] x 0� 46 = 2624 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,296 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 16 of 17 634:0 x x x x x X X x x x x x x x X x x x x x x x X X X x X x X x x X X X x x X x X 0.0280 X x x X x X X x X x x X X X X X x X X X X X X x x X X X X X x x x X X X X X X 46.0 = = = = = = = = = = = = = = = 817 838.2 0.0566 46.0 2,183 24.0 0.8000 46.0 883 94.8 0.5500 46.0 2,398 90.0 0.0572 46.0 237. 18.0 0.4000 46.0 331 perimeter = 106.0 45.5 4,823 Items shown with an asterisk (') denote conduction through an interior surface to another room. Page Total: 11,673 Infiltration:11.001 cheduex Air Sensible x Area Coiling X CoilingHeightx ACH50 /6] x 0� 46 = 2624 Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 14,296 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page: 16 of 17 RESIDENTIAL ROOM COOLING LOAD SUMMARY Lot #8 (Guest House) 7/19/2005 Project Title Date Room Name HVAC -1 Design Indoor Dry Bulb Temperature: Design Outdoor Dry Bulb Temperature: Design Temperature Difference: 780F 115°F 37°F Conduction Area U -Value DETD 1. Btu/hr X X X X X X X x X X (North) .56.0 = 994 X 2 CsmntWdw 4 35.6 = 1,690 X (West) 37.0 = 710 X 147 37.0 = 1,929 X 0.334 35.6 = 183 X 32)z 37.0 = 266 X X X 1. Design Equivalent Temperature Difference (DETD) Page Total 5 773 Items shown with an asterisk (') denote conduction through an interior surface to another room. Shaded Unshaded Solar Gain Orientation Area SGF , Area SGF Sc Btu/hr FrnchDr .1 (North) (North) 2 CsmntWdw 3 (North) 2 CsmntWdw 4 (South) (2)CsmntWdw (5)' (South) 3 FXdGISWdW 6 (West) 1 29.4 15)M 0.334 147 ( 0.0 ( 0.0 x1 x x x x x x x x x + + + + + + + + + + 24.0 x X x x x x x x x x 15) Z x )Z )Z )S )s 0.65 = = = = = = = = _ 236 ( 0.0 1 29.4 15)M 0.334 147 ( 0.0 1 29.4 15)Z 0.334 147 ( 0.0 1 6.0 32)z 0.334 64 ( 0.0 1 30.0 32) 0.334 321 ( 0.0 1 18.0 73)X 0.390 512 ( ( ( r ( Sched. Page Total 1 ata Internal Gain Frac. Area .. Heat Gain Btu/hr Lights 1.00 x 634 x 0.500 Watts/sgft x 3.41 BtuhlWatt = 1,082 Occupants 1.00 x 634 x 250 Btuh/occ. / 200 sgfJocc. = 792 Receptacle 1.00 x 634 x 1.500 Wafts/sgft x 3.413 Btuh/Watt = 3,246 Process 1.00 x 634 x .. %' 0.000 Watts/sgft x 3.412 Btuh/Watt = 0 Infiltration: x � x � . x x 60] 37 = ehedule Air Sensible Area Ceiling Height ACH LST Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 14431 Sched. Latent Gain Frac. Area Heat Gain Btu/hr Occupants 1.00 x 634 x 200 Btuh/occ. / 200 sgft/occ. = 634 Receptacle 1.00 x 634 x 0.000 Wafts/sgft x 3.41 Btt:h/Waft = o Process f1.00 x 634 x 0000 Wafts/sgft x 3.41 Btuh/Watt = Infiltration: I 1.00 x 4840 x 634 x 10.00 x 0.50 1601 O.00433 = 1 107 Schedule Air Latent Area Ceiling Height ACH ON' Fraction TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 1,741 EnergyPro 3.1 By EnergySoft User Number. 3665 Job Number. Page:17 of 17