Loading...
13-0290 (SOL)P.O. BOX 1504 78-495 CALLE TAMPICO LA QUINTA, CALIFORNIA 92253 Application Number: 13-00000290 Property Address: 79269 PASEO DEL REY APN: 604-440-020-20 -27519 - Application description: SOLAR Property Zoning: LOW DENSITY RESIDENTIAL Application valuation: 18000 w VOICE (760) 777-7012 FAX (760) 777-7011 BUILDING & SAFETY DEPARTMENT INSPECTIONS (760) 777-7153 BUILDING PERMIT Date: 4/30/13 Owner: CUMMINGS, DENNIS & MOLLY 79269 PASEO DEL REY LA QUINTA, CA 92253 "F1NANCFnPcrr actor: Applicant: Architect or Engineer:BOUND ELEC CONTR & SVCS 0 HIGHWAY 111 STE 3 DESERT, CA 92260 )776-8314 No.: 786678 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing, with Section 7000) of Division 3 of the Business and Professionals Code, and my License is in full force and effect. License Class: C10 License No.: 786678 /9 % ate: � Contractor: G GG✓t/R�l, . OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the following reason (Sec. 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption.. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).: 1 _ 1 I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does the work himself or herself through his or her own employees, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). 1 _ 1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). I—) I am exempt under Sec. , B.&P.C. for this reason Date: Owner: CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). Lender's Name: Lender's Address: LQPERMIT WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier HARTFORD UNDER Policy Number 57WECES1661 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, 1 shall forthwith comply with those provisions. Date: � Applicant: e WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000). IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. APPLICANT ACKNOWLEDGEMENT IMPORTANT Application is hereby made to theDirectorof Building and Safety for a permit subject to the conditions and restrictions set forth on this application. 1. Each person upon whose behalf this application is made, each person at whose request and for whose benefit work is performed under or pursuant to any permit issued as a result of this application, the owner, and the applicant, each agrees to, and shall defend, indemnify and hold harmless the City of La Quinta, its officers, agents and employees for any act or omission related to the work being performed under or following issuance of this permit. 2. Any permit issued as a result of this application becomes null and void if work is not commenced within 180 days from date of issuance of such permit, or cessation of work for 180 days will subject permit to cancellation. I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county �to",enter upon the above-mentioned property for inspection purposes. Date: kI AO / y Signature (Applicant or Agent): Application Number . . . . . 13-00000290 Permit . . . SOLAR PERMIT Additional desc . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation . . . . 35000 Expiration Date 10/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 4.5000 EA SOLAR COLLECTOR < 1000 4.50 1.00 3.0000 EA SOLAR EQUIP MISCELLANEOUS ---------------------------------------------------------------------------- 3.00 Permit . . . ELEC-SERVICE CHANGE Additional desc . Permit Fee . . . . 33.50 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date 10/27/13 Qty Unit Charge Per Extension BASE FEE 15.00 1.00 18.5000 EA ELEC SVC <=600V/<=200A ----------------=----------------------------------------------------------- 18.50 Permit ELEC-MISCELLANEOUS Additional desc . . Permit Fee . . . . 22.50 Plan Check Fee 5.63 Issue Date . . . . Valuation 0 Expiration Date 10/27/13 Qty Unit Charge Per Extension BASE FEE .15.00 1.00 7.5000 EA ELEC PWR APP >1 TO <=10 7.50 ---------------------------------------------------------------------------- Special Notes and Comments 8.OkW SOLAR ARRAY - (33) 245W CANADIAN SOLAR PANELS W/ (1) 7,000W SMA SUNNYBOY INVERTER AND 200AMP SERVICE PANEL UPGRADE [594SF] 2010 CALIFORNIA ELECTRICAL CODE. April 30, 2013 1:04:18 PM AORTEGA ------------------------------ ----------------------------------------------- Other Fees . . . . . . . . . BLDG STDS ADMIN (SB1473) 1.00 Fee summary Charged Paid Credited ------------------------------------------------=-------- Due Permit Fee Total 78.50 .00 .00 78.50 Plan Check Total 11.26 .00 .00 11.26 LQPERMIT Application Number Other Fee Total Grand Total LQPERMIT . . . . . 13-00000290 1.00 .00 .00 1.00 90.76 .00 .00 90.76 f Bin # City of La: Quinta BuikMg &r Safety Division Permit # P.O: Box'1504,18-4950116 Tampico 1.a.Qtifita, t -A 92253 (760)777-7012 «-0 d Bulk ing'Perm t Applicad6h:and Tracking Sheet ProjectAddcess:2 �id.p£l_(?� Own er'sName: . n(do A P. Number. Address: . % QZ(o ,f s9.SGO dd Legal Description: City, ST; Zip:A Telephone: (pp "I ' OS�� '• jest ription: . G-7 GVo I4 �- If Contractor: •L4p Address: City; ST, Zip: "i Tele hone: i q: -2f p 7 State Lic.#: �' ���,. City Lic:#; bvog7$�' - - AaL&NT S S t I Arch., Engr., Designer. 2� j Address: City., ST, Zip: i i Telephone: State Lic. #: Name of Contact Person: MG c.�� ,Construction Type:. S Occupancy: Project type (circle one): New d'n Alter Repair Demo Sq. Ft::. # nt Telephone # of Contact Person: (Q D'7 (4r'j — (p 9 a 3 Estiriiated Value oFog- tou on i APPLICANT: WNW WRITE.BEL•OW THIS` # Submittal Req'd Recd TRACKING PERMIT FEES Plan Sets Plan Check ubmitted Item Amount Strgctural Calm Reviewed, ready for corrections Plan Check Deposit. . Truss Calcs. Called Contact Person`� �i Plan Check Balance" Tide 24 Cales. Plans pleked up Constraedon Flood plain plan Plans resubmitted,' Mecharilcal Grading plan 2`' Review, ready for, correctio u Eleetrical Subcontactor List Called Contact Person Plumbing Grant Deed Plans picked.up S M L H.O.A- Approval Plans resubmitted Grading IN HOUSE:- ''d Review, ready for correctionvIssue Developer Impact Fee Planning Approval Called Contact Person A.I P.P. Pub. Wks. Appr " Date of permit Issue School Fees Total Permit Fees 4 ................ _....... .. ............._...._ .. 2WGroen­­�i eseft CA 2211 4 . 2 __ - . P 4.. t . '* . !". -1 ... , i * Di Showroom: 760.779;S'50:-1!* F, ax: RE: Residential Permit,for Roof -mount Solar Installation Location: Dennis Cummings residence 79269 Paseo Del Rey, La Qu i nta, CA *9.22 53 Sheet index: ® Vicinity Map ® Site Map and,Roof 'Plan, ® Labeling and signage ® Single.1ine Diagram * Solar Moclu.le,66ia'Sheet . ® Inverterbata Sheet Til6-roof solar'moubt datasheet Solar mount PE certification Racking d atasheet Prepared by: Matthew Acuff'for SCILA-UTE Coachella Valli WKS"! ffa �_M 44� 2oo �l *_A M 4L�a Q,��w vtbd 6V%51 (� ) CITY: -OF LA QUANTA BUILDING & SAFETY DEPT AP PRrOVED FOR -CONSTRUCTION LjPkI r .vjk ff- -7!_ �_ U F " .1. 0_U4 0 WSIF AWOO As AWMA VOW 'AMEM F" INA 'J WA An Ell si�'i f<9�'Jtsi , I t Atw 1 _ i 1p— XT i''�k`..�.�� • t! _ - Yy ? , . 3' -� �. ' _ � � +.� i � sem, ♦ - ..� i. R , 's" .. _ �- �"' wrl t 'T k �'r �.e .- ,� 1`. -•t r.�'-. - .., t`: , ._p.� j ! ' '' 1}yy x" "}fir'' • & y - ; ° ceovcI gas RnInis _ =11 ,(� ' t � J • . 'y :f',w:, r f to ., i Dennis Cummings residence - Solar Installation -_ 79269 Paseo del Rey, La Quinta, CA 92253 - a f ESTIMATED TIME TO COMPLETE FROM DELIVERY OF SYSTEM MATERIALS:2 WEEKS f.�i �- : CUTLER-HAMMER 2-POLE "` 240v UTILITY DISCONNECT . (LOCKABLE) DISCONNECT , 33 SOLAR MODULES Ay J-BOX LOCATIONS°z,° 60 ON ROOF SMA SB7000US INVERTER r (INSIDE GARAGE) r *} ,� 3-POLE DC ` DISCONNECT RAILS" (MOUNTS:4'MAX OC) s� 4 # - . -. • _,b. ��.- � 8THWN 2- 1 #10GRD . .4 .1., MAIN SERVICE /1-1/2"CONDUIT METER #1 134S101:139 � o � 4#8THWN-2 o 1 #10 GRD µ '�. 1-1/2"CONDUIT � � �� V 648THWN-2 I 1 #10 GRD ,,► 1 "CONDUIT UNDER EAVE JUNCTION BOX All construction shall comply with the 2010 California Residential, Mechanical, Electrical, Plumbing, Ener and Greeen Building Codes and the La Quinta Municipal Code. P Y 9 9Y- 9 P �fil S.OLA=LITE 42220 Green Way #B, Palm Desert, CA 92211 Showroom: 760.779.5591 Fax: 760.779.5597 Labeling and Signage for Photovoltaic Solar System with central. inverter(s): On exposed DC raceways every 1 Oft: "CAUTION: SOLAR CIRCUIT" On Main Service Entrance Panel: CITY*OF LA QUINTA BUILDING & SAFETY DEPT. VD FOR CONSTRUCTION DATE EY. "CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED" On AC Disconnect: "PV Solar System A/C Disconnect. Warning: Both Line And Load Terminals May Be Energized with Switch Open." On Inverter(s): "WARNING 690.5(C)-. ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED" At Breaker Main: "WARNING: INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE" On DC Disconnect: "PV Solar System DC Disconnect. Both Line And Load Terminals May Be Energized With Switch Open." P.O. Box 11571, Palm Desert, CA 92255 • www.puresunlight.com tel:760.779.5591, 888.779.5591 • fax:760:779.5597 • info@pureSunlight.com 0 lic#865370 NEM SYSTEM INFORMATION INVERTER MFG & MODEL SMA S137000US INVERTER EFFICIENCY RATING ' 966/b . PV MODULES PER INVERTER 33 (3 STRINGS OF:11 EA.) -NET NAMEPLATE RATING 7.074 kW DC DISCONNECT (3 -POLE) CONTINUOUS GROUND TO INVERTER FOR EQUIPMENT GROUNDING & INVERTERStUGS & RAIL'S r OVERCURRENT DEVICE -CALCULATION 33 x CS6P-245.M SOLAR MODULES 33 x 223.3 x 9.6% = 7074 W INVERTER MAX AC OUTPUT 29A x 125% = 36.25A MINIMUM BREAKER CONDUCTOR SIZING V) CONINUOUS GROUND TO GROUND 3 STRINGS OF 11 SOLAR MODULES PER STRING: > 6 #8 THWN-2 BUS IN MAIN ERVICE PANEL CALCULATED MAX SYSTEM DC OUTPUT AT LOWESTMIDDAY Canadian Solar CS6P-245M SOLARMODULES TYP.OF 33 w 1 #1.0 GROUND' LOCATION MAX PTC%CfC 223.3.W,Voc 37.4V, Isc 8.61 A zI' EMT* # '.h.--. .. .-. METER ' 30A. z S670001NVERTER ' 3 #8 THWN- 1 B4S101.139 IN,1 -1/2" EMT CONDUIT: ROOF 40A D WITH INTEGRATED-. 1 #10 GROUN #8 THWN (DC) . IN 1" CONDUIT: UNDER EAVES AC/DC DISCONNECT 1 " EMT*' 22.26A @ 333V #10GROUND (1 AS RI,S fUSE,PRO . Q #1-:0 USE -2 Z 0� 30A "-t Amp cF '7.g2A $ � TEcnoNATirwEFii> W O. SERVICE U ENTRANCE' �= 60 BUILDING & SAFETY EPT. BOXES: 70z 4- SEESfTEPIJIN fPDGC�n�t/YI�1i�✓ AMP 40AC/B: r P ' ' FOR1-BOX_ . I. LOCATEDOPPOSffE _ / LOCATIONS ORCONSTRUCTION #10 USE -2 UiJ� SIDE.FROMMAIN ' -CUTLER=HAMMER'2-0..OLE: 240V -UTILITY DISQONNECT: z ATE' gy (LOCKABLE).# DG2,22URB-. IID D"' ibutior' Tra sformer . - 1 OO KVA B'ph_ase ' Hi h 7 2K . -- ----- ---- ow 1207240V- L . . ;--- CONTINUOUS #10 GRD BOND -TO ALL RAILS & INVERTERStUGS & RAIL'S r OVERCURRENT DEVICE -CALCULATION 33 x CS6P-245.M SOLAR MODULES 33 x 223.3 x 9.6% = 7074 W INVERTER MAX AC OUTPUT 29A x 125% = 36.25A MINIMUM BREAKER CONDUCTOR SIZING SCHEDULE CALCULATED MAX SYSTEM DC OUTPUT AT LOWESTMIDDAY CONDUGTORS` LOCATION MAX #10 USE --2 (DC)- ON ROOF UNDER SOLAR MODS 30A. #8THWN (DC). IN,1 -1/2" EMT CONDUIT: ROOF 40A LOCAL TEfVTPURATURE #8 THWN (DC) . IN 1" CONDUIT: UNDER EAVES 40A 22.26A @ 333V #10GROUND UNDER MODULES & IN'EMT 30A "-t Amp cF '7.g2A $ � SITE CONTRACTOR DRAWING Dennis Cummings Residence - Solar Installation 79269 Paseo del Rey, La Quinta, CA 92253SO. ELECTRICAL: SINGLE LINE DIAGRAM LA. L UTILITY: IMPERIAL. IRRIGATION DISTRICT PO BOX 11571, PALM DESERT, CA 92255 (760) 779-5591 ®i� CanadianS®lar Key Features - • High'module efficiency up to 16.16% • Positive power tolerance: 0 - +5W. • Robust frame to up to 5400 Pa load: • Self-cleaning surface • Outstanding performance at low irradiance • High energy yield atLowNOCT . • Backed By Our'New 10/25 Linear Power Warranty; ., Plus our added.25 year insurance coverage' 100 s��8 Added Value Fr } ant so% am. Warr v 80 0% _77- 5 - 10 s '`.` 20 25' 10 year product warranty on materials and workmanship 25 year linearpower output warranty CS6P is a robust solar module with 60 solar cells. These modules can be used for on -grid solar applications. Our meticulous design and production techniques ensure a high -yield, long-term performance for every module produced. Our rigorous quality control and in-house testing facilities guarantee Canadian Solar's modules meet the highest quality standards possible. Best Quality • 235 quality control points in module production • EL screening to eliminate product defects • Current binning to improve system performance • Accredited Salt mist/Ammonia resistance Best Warranty Insurance • 25,years worldwide coverage,'• • 100% warranty term coverage • Providing third party, bankruptcy rights • Non7bancellable • Immediate coverage • Insured by 3 world top insurance companies Comprehensive Certificates • IEC 61215, IEC 61730, IEC61701 ED2', UL1703, IEC62716, CEC Listed, CE and MCS • IS09001: 2008: Quality Management System • ISO/TS16949:2009: The automotive quality management system •' IS014001'2004: Standards for Environmental management system • QC086600 HSPM: The Certifi6iition for Haiardous Substances Regulations • OHSAS 18001:2007: International standards for occupational health and safety 4. CERT www.canadiansolar.com CS6P-240/245/250/255/260M Electrical Data STC CS6P-240M CS6P-245M CS6P-250M CS6P-255M CS6P-260M Nominal Maximum Power (Pmax) 240W 245W 25OW 255W 260W Optimum Operating Voltage (Vmp) 30.2V 30.3V 30.4V 30.5V 30.7V Optimum Operating Current (Imp) 7.95A 8.09A 8.22A 8.35A 8.48A Open Circuit Voltage (Voc) 37.3V 37AV 37.5V 37.7V 37.8V Short Circuit Current (Isc) 8.46A 8.61A 8.74A 8.74A 8.99A Module Efficiency 14.92% 15.23% 15.54% 15.85% 16.16% Operating Temperature -40°C -+85°C Maximum System Voltage 1000V (IEC) /600V (UL) Maximum Series Fuse Rating 15A Application Classification ClassA Power Tolerance 0 - +5W Under Standard Test Conditions (STC) of Irradiance of t000W/m', spectrum AM 1.5 and cell temperature of 25C NOCT CS6P-240M CS6P-245M CS6P-250M CS6P-255M CS6P-260M Nominal Maximum Power (Pmax) 173W 177W 180W 184W 188W Optimum Operating Voltage (Vmp) 27.5V 27.6V 27.7V 27.8V 28.0V Optimum Operating Current (Imp) 6.29A 6.40A 6.51A 6.62A 6.70A Open Circuit Voltage (Voc) 34.2V 34.3V 34AV 34.6V 34.7V Short Circuit Current (Isc) 6.85A 6.97A 7.08A 7.18A 7.28A Under Normal Operating Cell Temperature, Irradiance of 800 W/m', spectrum AM 1.5, ambient temperature 20C, wind speed 1 m/s Mechanical Data Cell Type Mono -crystalline 156 x 156mm, 2 or 3 Busbars Cell Arrangement 60 (6 x 10) Dimensions 1638 x 982 x 40mm (64.5 x 38.7 x 1.57in) Weight 19kg (41.9 lbs) Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloy J -BOX IP65 or IP67, 3 diodes Cable 4mm2(IEC)/12AWG(UL), 1000mm Connectors MC4 or MC4 Comparable Standard Packaging (Modules per Pallet) 24pcs Module Pieces per container (40 ft. Container) 672pcs (40'HQ) IN Curves (CS6P-250M) E , vamp.(VI Vo;,ag.ryl 'Specifications Included in this datasheet are subject to change without prior notice. About Canadian Solar Canadian Solar Inc. is one of the world's largest solar companies. As a leading vertically -Integrated manufacturer of Ingots, wafers, cells, solar modules and solar systems, Canadian Solar delivers solar power products of uncompromising quality to worldwide customers. Canadian Solar's world class team of professionals works closely with our customers to provide them with solutions for all their solar needs. EN -Rev 3.52 Copyright 0 2013 Canadian Solar Inc. Sechon A -A 350 0 0 115 Temperature Characteristics Temperature Coefficient Pmax -0.45%FC Voc -0.35 %PC Isc 0.060 %/°C Normal Operating Cell Temperature 45*2°C Performance at Low Irradiance Industry leading performance at low irradiation environment, +95.5% module efficiency from an irradiance of 1000W/m2to 200w/m' (AM 1.5, 25 -C) Engineering Drawings Canadian Solar was founded in Canada in 2001 and was successfully listed on NASDAQ Exchange (symbol: CSIQ) in November 2006. Canadian Solar has cell manufacturing capacity of 1.5GW and module manufacturing capacity of 2.3GW. SMA SUNNY BOY 5000US / 6000US / 7000US / 8000US Highest CEC efhci n y rn rts'class �3Sealedeleomc�se�nclosure & Integra ed I od b er ak:ratedt.� �OphcoolT"�� .lockable DC d�scor Deet switch � 'Comprehensive SMAy Iritegroted rused serves stung s m commumcohons and dato combmec ; _ ;"collectwn.optrons t SUNNY BOY 5000US/6000US/7000US / 8000US The best in their class Our US series inverters utilize our proven technology and are designed specifically to meet IEEE -1547 requirements. Sunny Boy 6000US, Sunny Boy 7000US and Sunny Boy 8000US are also compatible with the Sunny Tower. Increased efficiency means better performance and shorter payback periods. All four models are field -configurable for positive ground systems making them more versatile than ever. Throughout the world, Sunny Boy is the benchmark for PV inverter performance and reliability. p r- Highest CEC efhci n y rn rts'class �3Sealedeleomc�se�nclosure & Integra ed I od b er ak:ratedt.� �OphcoolT"�� .lockable DC d�scor Deet switch � 'Comprehensive SMAy Iritegroted rused serves stung s m commumcohons and dato combmec ; _ ;"collectwn.optrons t SUNNY BOY 5000US/6000US/7000US / 8000US The best in their class Our US series inverters utilize our proven technology and are designed specifically to meet IEEE -1547 requirements. Sunny Boy 6000US, Sunny Boy 7000US and Sunny Boy 8000US are also compatible with the Sunny Tower. Increased efficiency means better performance and shorter payback periods. All four models are field -configurable for positive ground systems making them more versatile than ever. Throughout the world, Sunny Boy is the benchmark for PV inverter performance and reliability. Technical Data Efficiency Curves �/ SB 5000US SB 6000US SB 7000US SB 8000US Recommended Maximum PV Power (Module STC) 6250 W 7500 W 8750 W 10000 W DC Maximum Voltage 600V 600 V 600 V 600V Peak Power Tracking Voltage 250-480 V 250-480 V 250-480 V 300-480 V DC Maximum Input Current 21 A 25A 30A 30A Number of Fused String Inputs 3 (inverter), 4 x 20 A 3 (inverter), 4 x 20 A 3 (inverter), 4 x 20 A 3 (Inverter), 4 x 20 A (DC disconnect) (DC disconnect) (DC disconnect) (DC disconnect) PV Start Voltage 300 V 300 V 300 V 365 V AC Nominal Power 5000 W 6000 W 7000 W 8000 W AC Maximum Output Power 5000 W 6000 W 7000 W 8000 W AC Maximum Output Current (@ 208, 240, 277 V) 24 A, 21 A, 18 A 29 A, 25 A, 22 A 34 A, 29 A, 25 A N/A, 32 A, 29 A AC Nominal Voltage Range 183 - 229 V @ 208 V 183 - 229 V @ 208 V 183, 229 V @ 208 V N/A @ 208 V 211-264V@240V 211-264V@240V 211-264V@240V 211-264V@240V 244 - 305 V @ 277 V 244 - 305 V @ 277 V 244 - 305 V @ 277 V 244 - 305 V @ 277 V AC Frequency: nominal / range 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz 60 Hz / 59.3 - 60.5 Hz Power factor (Nominal) 0.99 0.99 0.99 0.99 Peak Inverter Efficiency 96.8% 97.0% 971% 96.5% CEC Weighted Efficiency 95.5% @ 208 V 95.5% @ 208 V _ 95.5% @ 208 V N/A @ 208 V 95.5% @ 240 V 95.5% @ 240 V 96.0% @ 240 V 96.0%@ 240 V 95.5% @ 277 V 96.0% @ 277 V 96.0% @ 277 V 96.0%@ 277 V Dimensions: W x H x D in inches 18.4 x 24.1 x 9.5 18.4 x 24.1 x 9.5 18.4 x 24.1 x 9.5 18.4 x 24.1 x 9.5 Weight / Shipping Weight 141 lbs / 148 lbs 141 lbs / 148 lbs 141 lbs / 148 lbs 148 lbs / 152 lbs Ambient Temperature Range -13 to 113 °F -13 to 113 °F -13 to 113 °F -13 to 113 °F Power consumption at night 0.1 W 0.1 W 0.1 W 0.1 W Topology Low frequency transformer, Low frequency transformer, low frequency transformer, Low frequency transformer, true sinewove true sinewave true sinewove true sinewove Cooling Concept Opticoollm" Opticoollm, Opticoollm, Optieooll", forced active cooling forced active cooling forced active cooling forced active cooling . Mounting Location: indoor/ outdoor (NEMA 3R) 0/40 - LCD Display 40 40 Communication: RS485 /wireless 0/0 0/0 0/0 0/0 Warranty: 10 years / 15 years / 20 years 40/0/0 40/0/0 0/0/0 0/0/0 Compliance: IEEE -929, IEEE -1547, UL 1741, 40 • • 40 UL 1998, FCC Part 15 A & B Specifications For nominal conditions • Included O Optional NOTE: US inverters ship with gray lids. Efficiency Curves �/ - Un-230VOC Urv-010VDC ^' - Up-MOVDC '� 1000 2000 9000 Aa00 Seeo .eem � 1000 PAC twt Tel. +1 916 625 0870 Toll Free +1 888 4 SMA USA www.SMA-America.com Yw dilY anducAivM pp�lamn. em -' ..,'.lyturury iaW as e,a ba.�:�nn bdanw iR �;� dma Gan aM PC f.1• mr:yaw m..no �_ �enlevee.rc N 'b �` m Z v SMA America, LLC s.w H ® e 5®LA92WA_REHOUSE'�s SWH Solar Mount Flat tile'roof bar,.- Part ar;Part No. MR -SW -RB -LOFT MateriaLer ting: XSCrNi1'810 1.4301 .Name according to DIN EN I50 3506:; (chem. symbol) (materia/ number) i.,Hardness A2-70 285 *UNITS IUMM M Solar.Warehouse 9628 Valley Blvd: -Rosemead; CA 917.70 'in 6I@,talm6ntecorp.coM 626579=3288 Density P.. = 7.9 9/cm x Co'efficientofthermal. expansion �.r ar = 1.60E -051/°C Diffusivity. A = 17.00 W/mK h Modulus of., elasticity E = 17,000.00 kN/cm2 Shear modulus' G = 6,450.00 kN/cm2 IVlechanical_:poperties . tensile strength: fu.k 700 MPa tensile.yielcl.stregth :fy, _ 450 MPa Permissible -*loads Tensile:force Minimum Rafter width 30 TF �= 0.80 kN b raker 60.mm 8.5 5. Average Ultimate Load Z± Fixed with 292lbs (1300N) hex head wood screw 8x80 571 fz N t'7 Average'UltimateLoad'•Y± N I N O N 157 lbs (700N) ' N lye �V A No t 285 *UNITS IUMM M Solar.Warehouse 9628 Valley Blvd: -Rosemead; CA 917.70 'in 6I@,talm6ntecorp.coM 626579=3288 Oct. 7, 2012 Calmonte .Corporation DBA SolanWarehouse 9628 Valley Blvd: Rosemead; CA :91=770 Phone: (626)579-328.8 Atte: Engineering<Department Subject: Engineering Certification for-:SWH Solar Racking Installation Guide (Verslon 12-iiV1) I, Hai -Hone, being a registered Professional Engineer a.the-State of California, P.E. # C68610i, and being duly competent as regards photovoltaic .(I?V) mounting systems designvand construction, has reviewed SWH Solar Racking V). systems Guide (Version :12 10:V1). -Part 1 Procedure to Determine.the. Design Wind Load", and "Part2. Procedure to Select Rail Span. and Foot Spacing" . $ymy.attached P E .seal, I certify -that the procedures which:are used�:to determine the, calculation of design wind force, load cgmbin_ ations, :appliedloading„rail selecrion,.data and analysis contained within this installation giide.'are based:on and comply with the design criteriaspecified in 1. 20.09 International Building Code; ;by Intematiorial Code; Council, Inc, 2009 2. 201.0 California -Building Code, by'.Cali-fornia Building Standards Commission, 20;1:1 3. Aluminum Design Manual: Specification and Guidelines for Aluminum Structures; by:The.,Aluminum Association, 2005. This engineering certif cation shall not be construed as relieving. the; manufacturer or installer of their responsibi sties, liabilities or contractual obligation. Itis the installer's responsibility to venfy that the exisfng building structure to which the PV mounting system is to be fixed is:a'dequate to support the load forces inducedLLby V, mounting. system. Please contact me if you' -should .have any questions. Yours faithfully Hai' Hong, PE Hai Flong P.E 0 4439 ,rlis.sion Hi4 Dr. Chino Hills CA 911709 o Phone: 909.606.9540 U "UNIIMC s A HILTI GROUP COMPANY Sol.aMount TO.chn,' ic',al PatOheet Pub 110818 -ltd V1.9 August 2011 SolarMount Module Connection Hardware ... ............................................................. 1 BottomUp, Module Clip ..................................... I ............................................. ........ MidClamp ................. ................................... i ...................... I ...................................... EndClamp ............................................. ................................. .......................................... ;;2. SolarMount Beam Connection 'Hardware ..... : ................................................................... i3 L -Foot .................................................................................... : ........................ ......... :..,;..3 SolarMountBeams ......................................................... ................... ................................ A SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Washer x Bottom Up Clip material: One of the folldwifig extruded aluminum Bottom 0t fhiydens a alloys: 6005 -T5,.6105 -T5, 6061-T6 Up C/' ArqF Ultimate tensile: 38ksi, Yield: 35 ksi 0 Finish: Clear Anodized Bottom Up Clio weight: -0.031 lbs (14g) BolAllbl BedIll t b w I a6 and d(esigh. Ibaidsbre valid when components are —�assembled-with SolarMoun't series beams according to authorized UNIRAC documerits Assemble with one'/4"-20 ASTM F593 bolt, one'/<" -20 ASTM F594 71 -serrated flange nut, and one .114". flatMwasher Use anti-seizeand tiahten.to 10 ft lbs of torque Resistance factors and safety factors are dei4rmined according to part 1 section 9 of the.2005 Aluminum Desigh Man uzil and third - party test results from an IAS a6dr6dit6d labdr"a*tory • Module edge must be'fully supported by the beam NOTE ON WASHER: Install washer'on'bolt head side of assembly. DO NOT. install, washer under serrated flangd hut 7 U 1.24 0,x Dimensions specified in inches unless noted Applied Load Direction Average Ultimate I bs (N) Allowable Load lbs (N) Safety Factor, j FS Design Load lbs (N) Resistance Factor, 0 Tension, Y+ 1566 (6967) 686 (3052) 2.28 10513 (4615) 0.662 Transverse,X±,' 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, t ;-, 1- 66 (292), 27 (119) 2.44 1 _41 (181)10.619 SolarMount Mid Clamp Part No. 302101 C, 302101 D, 302103C, 302104D, 302105D,302106D- Mi Clai BELW!!N NOOt1Ig5 �x Dimensions,specified in inches unless noted SolarMount End Clamp Part No. 302001C, 302002C, 302002D, 302003C, 302003D,302004C,302004D,302005C,302005D, 302006C,302006D,302007D,302008C,302008D, 302009C,302009D,302010C,302011C,302012C s 00 UNIRAC A HIITI GROUP COMPANY • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac'/4'-20 T -bolt and one'/4"-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate Ibs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, 0 Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 1 2.27 346 (1539) 0.665 Sliding, X± 1194 (5312) 1 490 (2179) 1 2.44 741 (3295) 0.620 ex Is a:x:w�x vAnaes wrrH VIODM I I THIO NBS t _. Dimensions specified=in-laiE ches-unless-noted • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: —0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac'/4'-20 T -bolt and one'/4'-20 ASTM F594 serrated flange nut • Use anti -seize and tighten to 10 ft -lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third - .party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, m Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Z± 63 (279) 14 (61) 4.58 21 (92) 0.330 Sliding, X± j 142 (630) 1 52 (231) 2.72 79 (349) 0.555 x p s O® �; w o®D U I I RAC 9,�,�' J �... i A HILTI GROUP COMPANY SolarMount• Bears -Connection Hardware . SolarMount L -Foot Average; Part No. 304000C, 304000D. s - Design Resistance L`-Foot.material i 'One of theldllowing extruded aluminum alloys: 6005- Ultimate: T5, 61,05-T5. 6061-T6 ' �. Factor, Ultimate tensile 38ksI veld 35 ksI �' Finish Clear or Dark Anodized. _ y Ibis. (N) L -Foot weight varies based omheight 0.215 lbs 98 lbs (N): m A!lowable,and design loadsare valid when.components are Bea ` ; �' may' assmbled ewith`SolarMount`senes'6i ams ac"'60rding to authorized Bolt•` - UNIRAGdocumenfs; . L -Foot " Foe the beam to L=Foot connection "" ' K •`Assemble with one'ASTM F593 W-16 hex head screw and one eiratedF594''%e"serrated"flange nut 'Flange Nb r pJ Use anti seiie and tighten to 30 ft -lbs of,torque 2.46, 'R*esistance:factors;and safety factors are determined according to,part ,• , ... :1 _section 4 of,the.26,05 Aluminum.Design Manual and third -party test Y results from anlAS'accredited laboratory 3231 1436 0.664 NOTE:, . Loads'are given for'tFie L Foot to'tieam connection only; be X sure.,to checkload, limits for standoff; lag screw, or other a ttachment method (. am ROT fQR .6 WDWAM 1. 2.01 ` t Dimensions specified in inches unless noted Applied load Average; Safety Design Resistance Direction' Ultimate: Allowable Load: �. Factor, Load Factor, . ,,. Ibs (N); _ y Ibis. (N) ,�.y..FS lbs (N): m `Sliding Z+; ,�Y1766 (7856), ;: . --755 (3356} �; -2.34 1141 (5077) 0.646 Tension Y+ ;:1859;(8269)'; 707: (3]44)' 2.63 1069 (4755) 0.575 Compression, Y.' 3258 {1:4492) 1'325.:(5893) 2.46, 2004' (8913) 0.615 ,r. Traverse ,X+;486 3231 1436 0.664 Man on UNIRAC A HILTI GROUP COMPANY SolarMount Beams Part No. 310132C, 310132C -B, 310168C, 310168C -B, 310168D 310208C,310208C-B,310240C,310240C-B,310240D, 410144M, 410168M, 410204M, 410240M Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in' 0.676 1.059 Section Modulus (X -Axis) in 0.353 0.898 Section Modulus (Y -Axis) in 0.113 0.221 Moment of Inertia (X -Axis) in 0.464 1.450 Moment of Inertia (Y -Axis) in 0.044 0.267 Radius of Gyration (X -Axis) in 0.289 1.170 Radius of Gyration (Y -Axis) in 0.254 0.502 SLOT FOR T -BOLT OR 1/4" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP SLOT FOR 38" HEX BOLT .387— .750 Y A sX SolarMount Beam -sj SLOT FOR T -BOLT OR 1.728 14" HEX HEAD SCREW SLOT FOR BOTTOM CLIP 3.000 Dimensions specified in inches unless noted a �I SLOT FOR HEX BOLT 1.385 1.207 Y 1.875 ►X SolarMount HD Beam Dimensions specified in inches unless noted a