CC Resolution 2009-028RESOLUTION NO. 2009-028
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
LA QUINTA, CALIFORNIA, APPROVING A SUBDIVISION
OF 25± ACRES INTO TEN PARCELS (FIVE FOR
CONDOMINIUM PURPOSES) LOCATED ON THE NORTH
SIDE OF FRED WARING DRIVE BETWEEN WASHINGTON
STREET AND PALM ROYALE DRIVE
CASE NO.: TENTATIVE PARCEL MAP 35088
APPLICANT: MAYER VILLA CAPRI, L.P.
WHEREAS, the City Council of the City of La Quinta, California, did on the
17" day of March, 2009, hold a duly -noticed Public Hearing to consider the request
of MAYER VILLA CAPRI for approval of Tentative Parcel Map 35088 which divides
25± acres into 10 commercial parcels (five for condominium purposes) for a
commercial complex and medical office complex located on the north side of Fred
Waring Drive between Washington Street and Palm Royale Drive more particularly
described as:
APN'S 609-070-053 AND 609-070-054
WHEREAS, the Planning Commission of the City of La Quinta, California, did
on the 24`" day of February, 2009, hold a duly -noticed Public Hearing on this
request and did recommend approval of Tentative Parcel Map 35088 by adoption
of Resolution 2009-008, subject to Conditions; and,
WHEREAS, said Tentative Parcel Map has been filed concurrently with a Site
Development Permit and Conditional Use Permit and in whole represents the
development permit applications for the project as contemplated; and,
WHEREAS, the Department has prepared a Final Environmental Impact
Report ("Final EIR"), State Clearinghouse #2007121009 in compliance with the
requirements of the California Environmental Quality Act (CEQA) of 1970 as
amended. The Final EIR was presented to the La Quinta City Council, which
reviewed and considered the information contained in the Final EIR, as well as all
testimony presented at the public hearing, and has adopted a Resolution certifying
that the Final EIR prepared for this application is recognized as adequate and
complete, recognizing the overriding considerations to certain significant
environmental impacts, and, recognizing the significant environmental effects
which cannot be avoided, but can be reasonably and substantially mitigated if the
proposed project is implemented; and
Resolution No. 2009-028
Tentative Parcel Map 35088
Mayer Villa Capri, L.P.
Adopted: March 17, 2009
Page 2
WHEREAS, the Planning Department did publish a public hearing notice in
the Desert Sun newspaper, on March 6, 2009 for the City Council hearing, and on
the 13t`' day of February, 2009 for the Planning Commission hearing, as prescribed
by the Municipal Code, with public hearing notices mailed to all property owners
within 500 feet of the property in question; and
WHEREAS, the Historic Preservation Commission, at their meeting held on
the 6th, day of December, 2007, reviewed the archaeological resources survey
associated with the application, and adopted a Minute Motion recommending
approval of the survey to the City Council, subject to staff -recommended
conditions; and
WHEREAS, at said Public Hearing, upon hearing and considering all
testimony and arguments of all interested persons desiring to be heard, the City
Council did make the following mandatory findings to justify approval of the
Tentative Parcel Map:
1. As proposed, Tentative Parcel Map 35088 is consistent with the La Quinta
General Plan. The Tentative Parcel Map is consistent with the Community
Commercial land use designation of the site in that the resulting parcels
conforms with the associated proposed condominium commercial and
medical uses.
2. The design and improvement of Tentative Parcel Map 35088 is consistent
with the La Quinta General Plan with the implementation of conditions of
approval to ensure proper street widths, and timing of their construction, as
well as adequate storm water drainage, street and other infrastructure
improvements. The Final EIR requires specific off -site improvements to
mitigate traffic -related impacts from this project. These improvements have
been incorporated into the approval conditions for the Project, and identified
in the Final EIR.
3. The design of Tentative Parcel Map 35088 and proposed improvements are
not likely to cause substantial environmental damage, nor substantially and
avoidably injure fish or wildlife or their habitat. No significant biological
resources have been identified to exist on the site. The Project site does not
contain and is not proximate to any wetland, blue -line stream, marsh, vernal
pool or other wildlife habit. The Project will not routinely use or transport any
hazardous materiallsj, nor are there any hazardous materials identified to
exist on the Project site. The Final EIR prepared for the Project, which
Resolution No. 2009-028
Tentative Parcel Map 35088
Mayer Villa Capri, L.P.
Adopted: March 17, 2009
Page 3
includes Tentative Parcel Map 35088, determined that there are no
significant impacts to air (permanent) or water quality, biological or cultural
resources, geology and soils which can not be mitigated to less than
significant levels, with incorporation of recommended mitigation measures
into the Project, which has been required.
4. The design of Tentative Parcel Map 35088 and type of improvements are
not likely to cause serious public health problems, in that this issue was
considered and addressed in the Final EIR prepared for the Project. The
Project will not routinely use or transport any hazardous material(s), nor are
there any hazardous materials identified to exist on the Project site. The Final
EIR prepared for the Project, which includes Tentative Parcel Map 30588,
determined that there are no significant impacts to air (permanent) or water
quality, geology soils, or other significant health or safety -related impacts
which cannot be mitigated to less than significant levels with
incorporation of mitigation measures into the Project, which has been
required.
5. The design and improvements required for Tentative Parcel Map 35088 will
not conflict with easements, acquired by the public at large, for access
through or use of property within the proposed subdivision. All necessary
right-of-way for construction of off -site improvements associated with this
site will be provided as required by the conditions of approval for this
Project.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of La
Quinta, California, as follows:
I. That the above recitations are true and constitute the Findings of the
City of La Quinta Council in this case;
II. That it does hereby approve Tentative Parcel Map 35088, as
referenced in the title of this Resolution, for the reasons set forth in this Resolution,
and subject to the attached Conditions of Approval.
PASSED, APPROVED, and ADOPTED at a regular meeting of the City of La
Quinta City Council, held on this the 17`h day of March, 2009, by the following
vote, to wit:
Resolution No. 2009-028
Tentative Parcel Map 35088
Mayer Villa Capri, L.P.
Adopted: March 17, 2009
Page 4
AYES: Council Member Franklin, Kirk, Sniff, Mayor Pro Tem Henderson
NOES: None
ABSENT: Mayor Adolph
ABSTAIN: None
TERRY NDERSON, Mayor Pro Tem
City of
Quinta, California
ATTEST:
(Seal)
APPROVED AS TO FORM:
M. Katherine J nso Ity Attorney
City of La Quint alifornia
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL — FINAL
ADOPTED: MARCH 17, 2009
GENERAL
1. The applicant agrees to defend, indemnify and hold harmless the City of La
Quinta ("City"), its agents, officers and employees from any claim, action or
proceeding to attack, set aside, void, or annul the approval of this Tentative
Parcel Map, or any Final Map recorded thereunder. The City shall have sole
discretion in selecting its defense counsel.
The City shall promptly notify the applicant of any claim, action or proceeding
and shall cooperate fully in the defense.
2. This Tentative Parcel Map, and any Final Map recorded thereunder, shall comply
with the requirements and standards of Government Code § § 66410 through
66499.58 (the "Subdivision Map Act"), and Chapter 13 of the La Quinta
Municipal Code ("LQMC").
This Tentative Parcel Map shall expire two years after City Council approval,
unless recorded or granted a time extension pursuant to the requirements of La
Quinta Municipal Code 9.200.080 (Permit expiration and time extensions).
The City of La Quinta's Municipal Code can be accessed on the City's Web Site
at www.la-quinta.org.
3. Prior to the issuance of any grading, construction, or building permit by the City,
the applicant shall obtain any necessary clearances and/or permits from the
following agencies, if required:
• Riverside County Fire Marshal
• Public Works Department (Grading Permit, Green Sheet (Public Works
Clearance) for Building Permits, Improvement Permit)
• Planning Department
• Riverside Co. Environmental Health Department
Desert Sands Unified School District
• Coachella Valley Water District (CVWD)
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 2 of 27
e Imperial Irrigation District (IID)
• California Water Quality Control Board (CWQCB)
• SunLine Transit Agency
• South Coast Air Quality Management District Coachella Valley
The applicant is responsible for all requirements of the permits and/or clearances
from the above listed agencies. When the requirements include approval of
improvement plans, the applicant shall furnish proof of such approvals when
submitting those improvements plans for City approval.
A project -specific NPDES construction permit must be obtained by the applicant;
and who then shall submit a copy of the Regional Water Quality Control Board's
("RWQCB") acknowledgment of the applicant's Notice of Intent ("NOI"), prior to
the issuance of a grading or site construction permit by the City.
4. The applicant shall comply with applicable provisions of the City's NPDES
stormwater discharge permit, LQMC Sections 8.70.010 at seq. (Stormwater
Management and Discharge Controls), and 13.24.170 (Clean Air/Clean Water);
Riverside County Ordinance No. 457; the California Regional Water Quality
Control Board — Colorado River Basin Region Board Order No. 137-2008-0001
and the State Water Resources Control Board's Order No. 99-08-DWQ.
A. For construction activities including clearing, grading or excavation of
land that disturbs one 0 ) acre or more of land, or that disturbs less than
one (1) acre of land, but which is a part of a construction project that
encompasses more than one (1) acre of land, the applicant shall be
required to submit a Storm Water Pollution Protection Plan ("SWPPP").
The applicant or design professional can obtain the California Stormwater
Quality Association SWPPP template at www.cabmphandbooks.com for
use in their SWPPP preparation.
B. The applicant's SWPPP shall be approved by the City Engineer prior to
any on or off -site grading being done in relation to this project.
C. The applicant shall ensure that the required SWPPP is available for
inspection at the project site at all times through and including
acceptance of all improvements by the City.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 3 of 27
D. The applicant's SWPPP shall include provisions for all of the following
Best Management Practices ("BMPs") (8.70.020 (Definitions), LQMC):
1) Temporary Soil Stabilization (erosion control).
2) Temporary Sediment Control.
3) Wind Erosion Control.
4) Tracking Control.
5) Non -Storm Water Management.
6) Waste Management and Materials Pollution Control.
E. All erosion and sediment control BMPs proposed by the applicant shall be
approved by the City Engineer prior to any onsite or offsite grading,
pursuant to this project.
F. The approved SWPPP and BMPs shall remain in effect for the entire
duration of project construction until all improvements are completed and
accepted by the City.
Additionally, the applicant shall comply with applicable provisions for post
construction runoff per the City's NPDES stormwater discharge permit, LQMC
Sections 8.70.010 et seq. (Stormwater Management and Discharge Controls),
and 13.24.170 (Clean Air/Clean Water); Riverside County Ordinance No. 457;
and the California Regional Water Quality Control Board — Colorado River Basin
(CRWQCB-CRB) Region Board Order No. 137-2008-001.
G. For post -construction urban runoff from New Development and
Redevelopment Projects, the applicant shall implement requirements of
the NPDES permit for the design, construction and perpetual operation
and maintenance of BMPs per the approved Water Quality Management
Plan (WQMP) for the project as required by the California Regional Water
Quality Control Board — Colorado River Basin (CRWQCB-CRB) Region
Board Order No. R7-2008-001.
H. The applicant shall implement the WQMP Design Standards per
(CRWQCB-CRB) Region Board Order No. R7-2008-001 utilizing BMPs
approved by the City Engineer.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 4 of 27
5. Permits issued under this approval shall be subject to the provisions of the
Infrastructure Fee Program and Development Impact Fee program in effect at
the time of issuance of building permit(s).
6. Approval of this Tentative Parcel Map shall not be construed as approval for any
horizontal dimensions implied by any site plans or exhibits unless specifically
identified in the following conditions of approval.
PROPERTY RIGHTS
7. Prior to issuance of any permit(s), the applicant shall acquire or confer
easements and other property rights necessary for the construction or proper
functioning of the proposed development. Conferred rights shall include
irrevocable offers to dedicate or grant access easements to the City for
emergency services and for maintenance, construction and reconstruction of
essential improvements. Said conferred rights shall also include grant of access
easement to the City of La Quinta for the purpose of graffiti removal by City
staff or assigned agent in perpetuity and agreement to the method to remove
graffiti and to paint over to best match existing. The applicant shall establish the
aforementioned requirements in the CC&R's for the development or other
agreements as approved by the City Engineer. Pursuant to the aforementioned,
the applicant shall submit an "AUTHORIZATION TO REMOVE GRAFFITI FROM
PRIVATE PROPERTY" form located at the Public Works Department Counter
prior to Certificate of Occupancy.
8. Pursuant to the aforementioned condition, conferred rights shall include
approvals from the master developer over easements and other property rights
necessary for construction and proper functioning of the proposed development
not limited to access rights over proposed and/or existing private streets that
access public streets and open space/drainage facilities of the master
development.
9. The applicant shall offer for dedication on the Final Map all public street rights -
of -way in conformance with the City's General Plan, Municipal Code, applicable
specific plans, and/or as required by the City Engineer.
10. The public street right-of-way offers for dedication required for this development
include:
A. PUBLIC STREETS
1) Washington Street (Major Arterial, 120' ROW) — The standard 60
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 5 of 27
feet from the centerline of Washington Street for a total 120-foot
ultimate developed right of way except an additional variable right
of way dedication on Washington Street:
a) at the intersection of Fred Waring Drive to provide for three
southbound through lanes (existing), a dual southbound left
turn lanes to eastbound Fred Waring Drive (existing), a
raised median, three northbound lanes consisting of a 13-
foot wide inside lane, a 12-foot wide middle lane, a 13-foot
wide curb lane and a 9-foot wide parkway as approved by
the City Engineer, and
b) a 12-foot deceleration/right turn only lane as shown on the
January 14, 2009 Site Plan to accommodate improvements
conditioned under STREET AND TRAFFIC IMPROVEMENTS.
Pursuant to the aforementioned conditions, the applicant
shall also design and construct improvements on
Washington Street to the south of the intersection with
Fred Waring Drive that are required to properly align and
safely transition to the Washington Street improvements
northerly of the Fred Waring Drive intersection as approved
by the City Engineer.
2) Fred Waring Drive (Major Arterial, 120' ROW) — The standard 60
feet from the centerline of Fred Waring Drive for a total 120-foot
ultimate developed right of way except an additional variable right
of way dedication on Fred Waring Drive:
a) at the intersection of Washington Street to provide for a 12-
foot parkway, 12-foot deceleration/right turn only lane,
three westbound through lanes, a dual westbound left turn
lanes to southbound Washington Street, and a raised
median as approved by the City Engineer. The proposed
right of way shall be measured 75 feet north of the
centerline of Fred Waring Drive as shown on the approved
Site Plan for this Tentative Parcel Map and as approved by
the City Engineer.
b) for a deceleration/right turn only lane at the westerly most
driveway on Fred Waring Drive to provide measured 87 feet
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P. .
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 6 of 27
north of the centerline of Fred Waring Drive for a length of
248 feet plus storage length and a transition taper of an
additional 150 feet (or length as approved by the City
Engineer) to accommodate improvements conditioned under
STREET AND TRAFFIC IMPROVEMENTS.
c) for a deceleration/right turn only lane at the easterly most
driveway on Fred Waring Drive as approved by the City
Engineer.
3) Palm Royale Drive (Pursuant to Parcel Map No. 27131 - Collector
Street, 72' ROW) — Street right of way has been dedicated with
recorded Parcel Map 27131. No additional right of way is required
to comply with General Plan street widths, except an additional
variable right of way dedication 1) at the northerly limits of the
Parcel Map of 44 feet from the centerline to align with Palm
Royale Drive right-of-way at the Desert Sands Unified School
District boundary and to transition as required to 36 feet from the
centerline at the Rome Drive intersection and 2) on Palm Royale
Drive at the Fred Waring Drive intersection measured 42 feet west
of the centerline to accommodate one left turn lane, one through
lane and one right turn lane and as conditioned under STREET AND
TRAFFIC IMPROVEMENTS.
11. Dedications shall include additional widths as necessary for dedicated right and
left turn lanes, bus turnouts, and other features contained in the approved
construction plans.
Pursuant to this requirement, the Applicant shall include in the submittal packet
containing the draft final map submitted for map checking, an offsite street
geometric layout, drawn at 1 " equals 40 feet, detailing the following design
aspects: median curb line, outside curb line, lane line alignment including lane
widths, left turn lanes, deceleration lane(s) and bus stop turnout(s). The
geometric layout shall be accompanied with sufficient professional engineering
studies to confirm the appropriate length of all proposed turn pockets and
auxiliary lanes that may impact the right of way dedication required of the
project and the associated landscape setback requirement.
12. When the City Engineer determines that access rights to the proposed street
rights -of -way shown on the approved Tentative Parcel Map are necessary prior
to approval of the Final Map dedicating such rights -of -way, the applicant shall
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 7 of 27
grant the necessary rights -of -way within 60 days of a written request by the
City.
13. The applicant shall offer for dedication on the Final Map a ten -foot wide public
utility easement contiguous with, and along both sides of all public streets.
Additional on -site utility easements shall be shown on the Final Map for this
Tentative Parcel Map as required by the utility purveyors.
14. The applicant shall create perimeter landscaping setbacks along all public rights -
of -way as follows:
A. Washington Street and Fred Waring Drive (Major Arterial) - 20-foot from
the R/W-P/L.
B. Palm Royale Drive (Collector Street) - 10-foot from the R/W-P/L.
The setback requirements shall apply to all frontages including, but not limited
to, remainder parcels and sites dedicated for utility purposes.
Where public facilities (e.g., sidewalks) are placed on privately -owned setbacks,
the applicant shall offer for dedication blanket easements for those purposes on
the Final Map.
15. The applicant shall offer for dedication those easements necessary for the
placement of, and access to, utility lines and structures, drainage basins,
mailbox clusters, park lands, and common areas on the Final Map.
16. Direct vehicular access to Washington Street, Fred Waring Drive and Palm
Royale Drive from lots with frontage along Washington Street, Fred Waring
Drive and Palm Royale Drive is restricted, except for those access points
identified on the Site Plan, or as otherwise conditioned in these conditions of
approval. The vehicular access restriction shall be shown on the recorded final
parcel map.
17. The applicant shall furnish proof of easements, or written permission, as
appropriate, from those owners of all abutting properties on which grading,
retaining wall construction, permanent slopes, or other encroachments will
occur.
18. The applicant shall cause no easement to be granted, or recorded, over any
portion of the subject property between the date of approval of the Tentative
Parcel Map and the date of recording of any Final Map, unless such easement is
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 8 of 27
approved by the City Engineer.
STREET AND TRAFFIC IMPROVEMENTS
19. The applicant shall construct the following street improvements to conform with
the General Plan (street type noted in parentheses.)
A. OFF -SITE STREETS
1) Washington Street (Major Arterial; 120' R/W):
Widen the east side of the street along all frontage adjacent to the
Tentative Parcel Map boundary to its ultimate width on the east side as
specified in the General Plan and the requirements of these conditions.
The east curb face shall be located fifty one feet (51') east of the
centerline, except at locations where additional street width is needed to
accommodate:
a) at the intersection of Fred Waring Drive to provide for three
southbound through lanes (existing), a dual southbound left
turn lanes to eastbound Fred Waring Drive (existing), a
raised median, three northbound lanes consisting of a 13-
foot wide inside lane, a 12-foot wide middle lane, a 13-foot
wide curb lane and a 9-foot wide parkway as approved by
the City Engineer, and
b) a 12-foot combined continuous deceleration/right turn only
lane as shown on the January 14, 2009 Site Plan.
Pursuant to the aforementioned conditions, the applicant
shall design and construct improvements on Washington
Street southerly of the intersection with Fred Waring Drive
as approved by the City Engineer to align and safely
transition to the improvements as conditioned northerly of
the intersection.
Other required improvements in the Washington Street right-of-way
and/or adjacent landscape setback area include:
c) All appurtenant components such as, but not limited to
curb, gutter, traffic control striping, legends, and signs,
RESOLUTION NO. 2OO9-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 9 of 27
d) 8-foot wide meandering sidewalk. The meandering sidewalk
shall have an arrhythmic horizontal layout that utilizes
concave and convex curves with respect to the curb line
that either touches the back of curb or approaches within
five feet of the curb at intervals not to exceed 250 feet.
The sidewalk curvature radii should vary between 50 and
300 feet and at each point of reverse curvature, the radius
should change to assist in creating the arrhythmic layout.
The sidewalk shall meander into the landscape setback lot
and approach within 5 feet of the perimeter wall at intervals
not to exceed 250 feet.
e) The design and installation of all traffic signal interconnect
equipment, conduit, pull boxes and appurtenances along the
frontage of the project for the interconnection of the
existing traffic signal at Washington Street and Fred Waring
Drive intersection to adjacent traffic signals.
f) Reconstruct the existing 14 - foot wide raised landscaped
median at the Primary Access Drive Aisle on Washington
Street to provide for left turn movement into the Primary
Access Driveway while restricting left turn movement out
of the Primary Access Driveway and left turn movement out
of Calle Las Brisas on the westerly side of Washington
Street as approved by the City Engineer.
g) Establish a benchmark in the Washington Street right of
way and file a record of the benchmark with the County of
Riverside.
h) Relocate the SunLine Transit Agency Bus Stop and Shelter
as required to incorporate the SunLine Transit Agency
requirements within the proposed deceleration lane.
The applicant shall extend improvements beyond the parcel map boundaries to
ensure they safely integrate with existing improvements (e.g., grading; traffic
control devices and transitions in alignment, elevation or dimensions of streets
and sidewalks).
2) Fred Waring Drive (Major Arterial; 120' R/W):
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 10 of 27
Widen the north side of Fred Waring Drive along all frontages adjacent to
the Tentative Parcel Map boundary to its ultimate width on the north side
as specified in the General Plan and the requirements of these conditions.
The north curb face shall be located fifty one feet (51') north of the
centerline, except at locations where additional street width is needed to
accommodate:
a) at the intersection of Washington Street to provide for a 12-
foot parkway, 12-foot deceleration/right turn only lane,
three westbound through lanes, dual westbound left turn
lanes to southbound Washington Street, and a raised
median as approved by the City Engineer. The proposed
right of way shall be measured 75 feet north of the
centerline of Fred Waring Drive as shown on the approved
Site Plan for the Site Development Permit and as approved
by the City Engineer.
b) for a deceleration/right turn only lane at the westerly most
driveway on Fred Waring Drive measured 87 feet north of
the centerline of Fred Waring Drive for a length of 248 feet
plus storage length and a transition taper of an additional
150 feet or length as approved by the City Engineer to
accommodate improvements conditioned under STREET
AND TRAFFIC IMPROVEMENTS.
c) for a deceleration/right turn only lane at the easterly most
driveway on Fred Waring Drive as approved by the City
Engineer.
Other required improvements in the Fred Waring Drive right-of-way and/or
adjacent landscape setback area include:
d) All appurtenant components such as, but not limited to:
curb, gutter, traffic control striping, legends, and signs,
e) An 8-foot wide meandering sidewalk. The meandering
sidewalk shall have an arrhythmic horizontal layout that
utilizes concave and convex curves with respect to the curb
line that either touches the back of curb or approaches
within five feet of the curb at intervals not to exceed 250
feet. The sidewalk curvature radii should vary between 50
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAVER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 11 of 27
and 300 feet and at each point of reverse curvature, the
radius should change to assist in creating the arrhythmic
layout. The sidewalk shall meander into the landscape
setback lot and approach within 5 feet of the perimeter wall
at intervals not to exceed 250 feet.
f) A 14 - foot wide raised landscaped median along the entire
boundary of the Tentative Parcel Map. plus variable width
as needed to accommodate 1) a raised median for the dual
left turn pockets for the eastbound traffic of Fred Waring
Drive to southbound Washington Street and left turn in
movements at Palm Royale Drive.
g) Reconstruct the raised median at the shared drive aisle at
Parcels 5 and 10 for a left turn deceleration lane with a left
turn out restrictor for a length and taper up to the dual left
turn lanes at the Fred Waring Drive and Washington Street
intersection as approved by the City Engineer.
h) Design and construct traffic signal equipment and
interconnect improvements along the project frontage
including conduit, pull boxes and other appurtenances for
the interconnection of the traffic signals.
i) Modification of the existing traffic signal at the Washington
Street and Fred Waring Drive intersection as required by the
abovementioned improvements and as approved by the City
Engineer and the City of Palm Desert. Applicant shall submit
plans and fees required for the City of Palm Desert
concurrent approval.
j) Class II Bike Lane as approved by the City Engineer.
3) Palm Royale Drive (Pursuant to Parcel Map No. 27131 - Collector
Street, 72' ROW):
Widen the west side of the street along all frontage adjacent to the
Tentative Parcel Map boundary to its ultimate width on the west side as
specified in the General Plan and the requirements of these conditions.
The west curb face shall be located twenty four feet (24') west of the
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAVER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 12 of 27
centerline, except at locations where additional street width is needed to
accommodate:
a) Transitional street width required from 32 feet at the
northerly boundary adjacent to the Colonel Mitchell Page
Middle School to 24 feet at Rome Drive as approved by the
City Engineer.
b) A deceleration/right turn only lane on Palm Royale at the
Fred Waring Drive intersection. The west curb face shall be
located thirty two (32') west of the centerline and length to
be as approved by the City Engineer to extend from the
Access Drive across Rome Drive to Fred Waring Drive. to
accommodate one left turn lane, one through lane and one
right turn lane,
Other required improvements in the Palm Royale Drive right-of-way
and/or adjacent landscape setback area include:
c) All appurtenant components such as, but not limited to:
curb, gutter, traffic control striping, legends, and signs,
d) 6-foot wide sidewalk with a planter adjacent to curb.
e) Class II Bike Lane to connect with the existing Bike Lane to
the north and as required by the City Engineer.
f) The applicant is responsible for a 25% share of the cost to
design and install the traffic signal at the intersection of
Palm Royale Drive and Fred Waring Drive that will be
installed by the City of La Quinta CIP Project 2007-06.
g) The applicant is responsible for the cost to design and install
all traffic signal equipment including conduit, pull boxes and
other appurtenances for the interconnection of this traffic
signal with the existing traffic signal at the Washington Street
and Fred Waring Drive intersection as approved by the City
Engineer.
The applicant shall extend improvements beyond the parcel map boundaries to
ensure they safely integrate with existing improvements (e.g., grading; traffic
control devices and transitions in alignment, elevation or dimensions of streets
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 13 of 27
and sidewalks)
20. The applicant shall design street pavement sections using CalTrans' design
procedure for 20-year life pavement, and the site -specific data for soil strength
and anticipated traffic loading (including construction traffic). Minimum
structural sections shall be as follows:
Collector 4.0" a.c /5.0" c.a.b.
Major Arterial 5.5" a.c./6.5" c.a.b.
or the approved equivalents of alternate materials.
21. The applicant shall submit current mix designs (less than two years old at the
time of construction) for base, asphalt concrete and Portland cement concrete.
The submittal shall include test results for all specimens used in the mix design
procedure. For mix designs over six months old, the submittal shall include
recent (less than six months old at the time of construction) aggregate gradation
test results confirming that design gradations can be achieved in current
production. The applicant shall not schedule construction operations until mix
designs are approved.
22. General access points and turning movements of traffic are limited to the
following:
A. Washington Street
1) Primary Access Drive (between Parcel 1 and 2): Right turn
movements in and out and left turn movements in are permitted.
Left turn movement out is prohibited.
2) Secondary Access Drive (northerly end of Tentative Parcel Map):
Right turn movements in and out are permitted. Left turn
movements in and out are prohibited.
B. Fred Waring Drive
1) Service Access Drive between Parcel 5 and 10: Right turn
movements in and out and left turn movements in are permitted.
Left turn movements out are prohibited.
2) Westerly most driveway to Parcel 3 between Parcels 4 and 5 on
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 14 of 27
Fred Waring Drive: Right turn movements in and out turn
movements are permitted. Left turn movements in and out are
prohibited.
3) Secondary most easterly Access Drive to Parcels 9 and 10. Right
turn movements in and out are permitted. Left turn movements in
and out are prohibited.
C. Palm Royale Drive
1) Access Drive across Rome Drive: Full turn movements are
permitted.
23. Improvements shall include appurtenances such as traffic control signs,
markings and other devices, raised medians if required, street name signs and
sidewalks. Mid -block street lighting is not required.
24. Improvements shall be designed and constructed in accordance with City
adopted standards, supplemental drawings and specifications, or as approved by
the City Engineer. Improvement plans for streets, access gates and parking
areas shall be stamped and signed by qualified engineers.
PARKING LOTS and ACCESS POINTS
25. The design of parking facilities shall conform to LQMC Chapter 9.150 (Parking).
In particular, the following are conditioned with this approval.
A. Accessibility routes to public streets and adjacent development shall be
shown on the Precise Grading Plan.
B. Cross slopes should be a maximum of 2% where ADA accessibility is
required including accessibility routes between buildings.
C. Building access points shall be shown on the Precise Grading Plans to
better evaluate ADA accessibility issues.
D. Parking stall lengths shall be according to LQMC Chapter 9.150 and be a
minimum of 17 feet in length for standard parking stalls and 18 feet for
handicapped parking stalls or as approved by the City Engineer.
RESOLUTION NO. 2OO9-028
TENTATIVE PARCEL MAP 35088
MAVER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 15 of 27
E. Drive aisles between parking stalls shall be a minimum of 26 feet with
egress drive aisles a minimum of 30 feet or as approved by the City
Engineer.
F. Drive-thru aisles shall be a minimum of 12 feet along straight away
portions and increased to a minimum 14 feet at bends (to accommodate
turning movements). The minimum dimensions shall be paved roadway
surface. Additionally for the drive-thru proposed at Building 10, a seven -
car minimum stacking capacity is required from the order window to the
drive-thru entrance off of the east -west drive aisle or as approved by the
City Engineer. Additionally, the applicant shall construct signage and
pavement markings to prevent vehicles blocking this east -west drive aisle
as approved by the City Engineer.
Entry drives, main interior circulation routes, corner cutbacks, bus turnouts,
dedicated turn lanes, ADA accessibility route to public streets and other
features shown on the approved construction plans, may require additional
street widths and other improvements as may be determined by the City
Engineer. Site Plan dated January 14, 2009 requires additional revisions based
on Public Works Department plan review of said Site Plan.
26. General access points and turning movements of traffic to off site public streets
are limited to the access locations approved for Parcel Map No. 35088 and
these conditions of approval.
27. The applicant shall design street pavement sections using CalTrans' design
procedure for 20-year life pavement, and the site -specific data for soil strength
and anticipated traffic loading (including construction traffic). Minimum
structural sections shall be as follows:
Parking Lot & Aisles (Low Traffic) 3.0" a.c./4.5" c.a.b.
Parking Lot & Aisles (High Traffic) 4.5" a.c./5.5" c.a.b.
Loading Areas 6" P.C.C./4" c.a.b.
or the approved equivalents of alternate materials.
28. The applicant shall submit current mix designs (less than two years old at the
time of construction) for base, asphalt concrete and Portland cement concrete.
The submittal shall include test results for all specimens used in the mix design
procedure. For mix designs over six months old, the submittal shall include
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL — FINAL
ADOPTED: MARCH 17, 2009
Page 16 of 27
recent (less than six months old at the time of construction) aggregate gradation
test results confirming that design gradations can be achieved in current
production. The applicant shall not schedule construction operations until mix
designs are approved.
29. Improvements shall include appurtenances such as traffic control signs,
markings and other devices, raised medians if required, street name signs and
sidewalks. Mid -block street lighting is not required.
30. Improvements shall be designed and constructed in accordance with City
adopted standards, supplemental drawings and specifications, or as approved by
the City Engineer. Improvement plans for streets, access gates and parking
areas shall be stamped and signed by qualified engineers.
31. The applicant is required to eliminate parking stalls along the main entry drive
aisle along the Primary Entry off of Washington Street up to Building 5 as
shown on the Site Plan dated January 14, 2009 and as approved by the City
Engineer.
32. The applicant is required to redesign the parking lot layout between Buildings 4
and 5 as approved by the City Engineer.
33. The applicant is required to address the westerly edge of the westerly parking
stalls adjacent to the Office Building 11 as approved by the City Engineer.
FINAL MAPS
34. Prior to the City's approval of a Final Map, the applicant shall furnish accurate
mylars of the Final Map that were approved by the City's map checker on a
storage media acceptable to the City Engineer. The Final Map shall be 1 " = 40'
scale.
IMPROVEMENT PLANS
As used throughout these Conditions of Approval, professional titles such as
"engineer," "surveyor," and "architect," refer to persons currently certified or licensed
to practice their respective professions in the State of California.
35. Improvement plans shall be prepared by or under the direct supervision of
qualified engineers and/or architects, as appropriate, and shall comply with the
provisions of Section 13-24.040 (Improvement Plans), LQMC.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 17 of 27
36. The following improvement plans shall be prepared and submitted for review
and approval by the Public Works Department. A separate set of plans for each
line item specified below shall be prepared. The plans shall utilize the minimum
scale specified, unless otherwise authorized by the City Engineer in writing.
Plans may be prepared at a larger scale if additional detail or plan clarity is
desired. Note, the applicant may be required to prepare other improvement
plans not listed here pursuant to improvements required by other agencies and
utility purveyors.
A.
On -Site Rough Grading Plan
1 "
= 40'
Horizontal
B.
PM10 Plan
1"
= 40'
Horizontal
C.
SWPPP
1"
= 40'
Horizontal
D. WQMP (Plan submitted in Report Form)
NOTE: A through D to be submitted concurrently.
E. Off -Site Street Improvement/Storm Drain Plan
F. Off -Site Signing & Striping Plan
1 " = 40' Horizontal,
1 " = 4' Vertical
1 " = 40' Horizontal
G. Washington Street/Fred Waring Drive Traffic Signal Modification Plan
1 " = 20' Horizontal
The Off -Site street improvement plans shall have separate plan sheet(s)
(drawn at 20 scale) that show the meandering sidewalk, mounding, and
berming design in the combined parkway and landscape setback area.
H. Traffic Signal Interconnect Plan
1 " =
40'
Horizontal
I. Precise Grading Plan
1" =
30'
Horizontal
NOTE: E through I to be submitted concurrently.
Other engineered improvement plans prepared for City approval that are not
listed above shall be prepared in formats approved by the City Engineer prior to
commencing plan preparation.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 18 of 27
All Off -Site Plan & Profile Street Plans and Signing & Striping Plans shall show
all existing improvements for a distance of at least 200-feet beyond the project
limits, or a distance sufficient to show any required design transitions.
"Rough Grading" plans shall normally include perimeter walls with Top Of Wall
& Top Of Footing elevations shown. All footings shall have a minimum of 1-
foot of cover, or sufficient cover to clear any adjacent obstructions.
The applicant shall prepare an accessibility assessment on a marked up print of
the building floor plan identifying every building egress and notes the 2001
California Building Code accessibility requirements associated with each door.
The assessment must comply with submittal requirements of the Building &
Safety Department. A copy of the reviewed assessment shall be submitted to
the Engineering Department in conjunction with the Site Development Plan
when it is submitted for plan checking.
In addition to the normal set of improvement plans, a "Precise Grading" plan is
required to be submitted for approval by the Building Official and the City
Engineer.
"Precise Grading" plans shall normally include all on -site surface improvements
including but not necessarily limited to finish grades for curbs & gutters,
building floor elevations, parking lot improvements and ADA requirements.
37. The City maintains standard plans, detail sheets and/or construction notes for
elements of construction which can be accessed via the "Plans, Notes and
Design Guidance" section of the Public Works Department at the City website
(www.la-quinta.orq). Please navigate to the Public Works Department home
page and look for the Standard Drawings hyperlink.
38. The applicant shall furnish a complete set of the mylars of all approved
improvement plans on a storage media acceptable to the City Engineer.
39. Upon completion of construction, and prior to final acceptance of the
improvements by the City, the applicant shall furnish the City with reproducible
record drawings of all improvement plans which were approved by the City.
Each sheet shall be clearly marked "Record Drawing," "As -Built" or "As -
Constructed" and shall be stamped and signed by the engineer or surveyor
certifying to the accuracy and completeness of the drawings. The applicant
shall have all approved mylars previously submitted to the City, revised to
reflect the as -built conditions. The applicant shall employ or retain the Engineer
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 19 of 27
Of Record during the construction phase of the project so that the EOR. can
make site visits in support of preparing As Built drawings. However, if
subsequent approved revisions have been approved by the City Engineer and
reflect said "As -Built" conditions, the Engineer Of Record may submit a letter
attesting to said fact to the City Engineer in lieu of mylar submittal.
IMPROVEMENT SECURITY AGREEMENTS
40. Prior to approval of any Final Map, the applicant shall construct all on and off -
site improvements and satisfy its obligations for same, or shall furnish a fully
secured and executed Subdivision Improvement Agreement ("SIA") guaranteeing
the construction of such improvements and the satisfaction of its obligations for
same, or shall agree to any combination thereof, as may be required by the City.
41. Any Subdivision Improvement Agreement ("SIA") entered into by and between
the applicant and the City of La Quinta, for the purpose of guaranteeing the
completion of any improvements related to this Tentative Parcel Map, shall
comply with the provisions of Chapter 13.28 (Improvement Security), LQMC.
42. Improvements to be made, or agreed to be made, shall include the removal of
any existing structures or other obstructions which are not a part of the
proposed improvements; and shall provide for the setting of the final survey
monumentation.
When improvements are phased through a "Phasing Plan," or an administrative
approval (e.g., Site Development Permits), all off -site improvements and
common on -site improvements (e.g., backbone utilities, retention basins,
perimeter walls, landscaping and gates) shall be constructed, or secured through
a SIA, prior to the issuance of any permits in the first phase of the
development, or as otherwise approved by the City Engineer.
Improvements and obligations required of each subsequent phase shall either be
completed, or secured through a SIA, prior to the occupancy of permanent
buildings within such latter phase, or as otherwise approved by the City
Engineer.
In the event the applicant fails to construct the improvements for the
development, or fails to satisfy its obligations for the development in a timely
manner, pursuant to the approved phasing plan, the City shall have the right to
halt issuance of all permits, and/or final inspections, withhold other approvals
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 20 of 27
related to the development of the project, or call upon the surety to complete
the improvements.
43. Depending on the timing of the development of this Tentative Parcel Map, and
the status of the off -site improvements at the time, the applicant may be
required to:
A. Construct certain off -site improvements.
B. Construct additional off -site improvements required for development of
this project, subject to the reimbursement of its costs by others.
C. Reimburse others for those improvements previously constructed that are
considered to be an obligation of this tentative parcel map.
D. Secure the costs for future improvements that are to be made by others.
E. To agree to any combination of these means, as the City may require.
Off -Site Improvements should be completed on a first priority basis. The
applicant shall complete Off -Site Improvements in the first phase of
construction or by the issuance of the prior to the first building occupancy.
In the event that any of the improvements required for this development which
this project is conditioned to provide are constructed by the City, the applicant
shall, prior to the approval of the Final Map, or the issuance of any permit
related thereto, reimburse the City for the project's proportionate share of the
costs of such improvements to the satisfaction of the City Engineer.
44. If the applicant elects to utilize the secured agreement alternative, the applicant
shall submit detailed construction cost estimates for all proposed on -site and
off -site improvements, including an estimate for the final survey
monumentation, for checking and approval by the City Engineer. Such
estimates shall conform to the unit cost schedule adopted by City resolution, or
ordinance.
For items not listed in the City's unit cost schedule, the proposed unit costs
shall be approved by the City Engineer.
At the time the applicant submits its detailed construction cost estimates for
conditional approval of the Final Map by the City Council, the applicant shall
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 21 of 27
also submit one copy each of an 8-1/2" x 11" reduction of each page of the
Final Map, along with a copy of an 8-1/2" x 11" Vicinity Map.
Estimates for improvements under the jurisdiction of other agencies shall be
approved by those agencies and submitted to the City along with the applicant's
detailed cost estimates.
Security will not be required for telephone, natural gas, or Cable T.V.
improvements.
GRADING
45. The applicant shall comply with the provisions of Section 13.24.050 (Grading
Improvements), LQMC.
46. Prior to occupancy of the project site for any construction, or other purposes,
the applicant shall obtain a grading permit approved by the City Engineer.
47. To obtain an approved grading permit, the applicant shall submit and obtain
approval of all of the following:
A. A grading plan prepared by a qualified engineer,
B. A preliminary geotechnical ("soils") report prepared by a qualified
engineer,
C. A Fugitive Dust Control Plan prepared in accordance with Chapter 6.16,
(Fugitive Dust Control), LQMC, and
D. A Best Management Practices report prepared in accordance with
Sections 8.70.010 and 13.24.170 (NPDES stormwater discharge permit
and Storm Management and Discharge Controls), LQMC.
All grading shall conform to the recommendations contained in the Preliminary
Soils Report, and shall be certified as being adequate by a soils engineer, or by
an engineering geologist.
A statement shall appear on the Final Map that a soils report has been prepared
in accordance with the California Health & Safety Code § 17953.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 22 of 27
The applicant shall furnish security, in a form acceptable to the City, and in an
amount sufficient to guarantee compliance with the approved Fugitive Dust
Control Plan provisions as submitted with its application for a grading permit.
48. The applicant shall maintain all open graded, undeveloped land in order to
prevent wind and/or water erosion of such land. All open graded, undeveloped
land shall either be planted with interim landscaping, or stabilized with such
other erosion control measures, as were approved in the Fugitive Dust Control
Plan.
49. Grading within the perimeter setback and parkway areas shall have undulating
terrain and shall conform with the requirements of LQMC Section 9.60.240(F)
except as otherwise modified by this condition requirement. The maximum
slope shall not exceed 3:1 anywhere in the landscape setback area, except for
the backslope (i.e. the slope at the back of the landscape lot) which shall not
exceed 2:1 if fully planted with ground cover. The maximum slope in the first
six (6) feet adjacent to the curb shall not exceed 4:1 when the nearest edge of
sidewalk is within six feet (6') of the curb, otherwise the maximum slope within
the right of way shall not exceed 3:1. All unpaved parkway areas adjacent to
the curb shall be depressed one and one-half inches (1.5") in the first eighteen
inches (18") behind the curb.
50. Building pad elevations on the rough grading plan submitted for City Engineer's
approval shall conform with pad elevations shown on the tentative parcel map,
unless the pad elevations have other requirements imposed elsewhere in these
Conditions of Approval.
51. The applicant shall minimize the differences in elevation between the adjoining
properties and the lots within this development.
Where compliance within the above stated limits is impractical, the City may
consider alternatives that are shown to minimize safety concerns, maintenance
difficulties and neighboring -owner dissatisfaction with the grade differential.
52. Prior to any site grading or regrading that will raise or lower any portion of the
site by more than plus or minus five tenths of a foot (0.5') from the elevations
shown on the approved Tentative Parcel Map, the applicant shall submit the
proposed grading changes to the City Staff for a substantial conformance
finding review.
53. Prior to the issuance of a building permit for any building lot, the applicant shall
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 23 of 27
provide a lot pad certification stamped and signed by a qualified engineer or
surveyor with applicable compaction tests and over excavation documentation.
Each pad certification shall list the pad elevation as shown on the approved
grading plan, the actual pad elevation and the difference between the two, if
any. Such pad certification shall also list the relative compaction of the pad
soil. The data shall be organized by lot number, and listed cumulatively if
submitted at different times.
11:7T11I01Ie[el9
54. The applicant shall comply with the provisions of LQMC Section 13.24.120
(Drainage), Retention Basin Design Criteria, Engineering Bulletin No. 06-16 —
Hydrology Report with Preliminary Hydraulic Report Criteria for Storm Drain
Systems and Engineering Bulletin No. 06-015 - Underground Retention Basin
Design Requirements. More specifically, stormwater falling on site plus offsite
water to the street centerline tributary area during the 100 year storm shall be
retained within the development, unless otherwise approved by the City
Engineer. The design storm shall be either the 1 hour, 3 hour, 6 hour or 24 hour
event producing the greatest total run off. Retention volume requirements are
documented in the MSA October 15, 2006 Hydrology Report to equal 8.18
acre-feet.
55. Nuisance water shall be retained on site. Nuisance water shall be disposed of
per approved methods contained in Engineering Bulletin No. 06-16 — Hydrology
Report with Preliminary Hydraulic Report Criteria for Storm Drain Systems and
Engineering Bulletin No. 06-015 - Underground Retention Basin Design
Requirements.
56. In design of retention facilities, the maximum percolation rate shall be two
inches per hour. The percolation rate will be considered to be zero unless the
applicant provides site specific data indicating otherwise and as approved by the
City Engineer.
57. The project shall be designed to accommodate purging and blowoff water
(through underground piping and/or retention facilities) from any on -site or
adjacent well sites granted or dedicated to the local water utility authority as a
requirement for development of this property.
58. No fence or wall shall be constructed around any retention basin unless
approved by the Planning Director and the City Engineer.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 24 of 27
59. For on -site above ground common retention basins, retention depth shall be
according to Engineering Bulletin No. 06-16 — Hydrology Report with
Preliminary Hydraulic Report Criteria for Storm Drain Systems. Side slopes shall
not exceed 3:1 and shall be planted with maintenance free ground cover.
Additionally, retention basin widths shall be not less than 20 feet at the bottom
of the basin.
60. Stormwater may not be retained in landscaped parkways or landscaped setback
lots. Only incidental storm water (precipitation which directly falls onto the
setback) will be permitted to be retained in the landscape setback areas. The
perimeter setback and parkway areas in the street right-of-way shall be shaped
with berms and mounds, pursuant to LQMC Section 9.100.040(B)(7).
61. The design of the development shall not cause any increase in flood boundaries
and levels in any area outside the development.
62. The development shall be graded to permit storm flow in excess of retention
capacity to flow out of the development through a designated overflow and into
the historic drainage relief route.
63. Storm drainage historically received from adjoining property shall be received
and retained or passed through into the historic downstream drainage relief
route.
I1TII ITIFS
64. The applicant shall obtain the approval of the City Engineer for the location of all
utility lines within any right-of-way, and all above -ground utility structures
including, but not limited to, traffic signal cabinets, electric vaults, water valves,
and telephone stands, to ensure optimum placement for practical and aesthetic
purposes.
65. Existing overhead utility lines within, or adjacent to the proposed development,
and all proposed utilities shall be installed underground.
All existing utility lines attached to joint use 92 KV transmission power poles
are exempt from the requirement to be placed underground.
66. Underground utilities shall be installed prior to overlying hardscape. For
installation of utilities in existing improved streets, the applicant shall comply
with trench restoration requirements maintained, or required by the City
Engineer.
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 25 of 27
The applicant shall provide certified reports of all utility trench compaction for
approval by the City Engineer.
CONSTRUCTION
67. The City will conduct final inspections of habitable buildings only when the
buildings have improved street and (if required) sidewalk access to publicly -
maintained streets. The improvements shall include required traffic control
devices, pavement markings and street name signs. Temporary occupancy
permits, for the purpose of allowing fixture interior improvements will be
allowed.
LANDSCAPE AND IRRIGATION
68. The applicant shall comply with LQMC Sections 13.24.130 (Landscaping
Setbacks) & 13.24.140 (Landscaping Plans).
69. The applicant shall provide landscaping in the required setbacks and retention
basins, common lots areas.
70. Landscape and irrigation plans for landscaped lots and setbacks, medians and
retention basins shall be signed and stamped by a licensed landscape architect.
71. The applicant shall submit the final landscape plans for preliminary approval by
the Planning Department and green sheet sign off by the Public Works
Department. After plan checking has been completed by the Planning
Department, the applicant shall obtain the signatures of CVWD and the
Riverside County Agricultural Commissioner, prior to submittal for signature by
the Planning Director, however landscape plans for landscaped median on public
streets shall be approved by the both the Planning Director and the City
Engineer. Where City Engineer approval is not required, the applicant shall
submit for a green sheet approval by the Public Works Department.
Final irrigation and landscape plans for on -site planting shall be reviewed by the
ALRC and approved by the Planning Director prior to issuance of first building
permit. Final plans shall include all landscaping associated with this project.
NOTE: Plans are not approved for construction until signed by both the
Planning Director and/or the City Engineer.
72. Landscape areas shall have permanent irrigation improvements meeting the
requirements of the Planning Director. Use of lawn areas shall be minimized
RESOLUTION NO. 2009-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 26 of 27
with no lawn, or spray irrigation, being placed within 24 inches of curbs along
public streets.
73. The applicant or his agent has the responsibility for proper sight distance
requirements per guidelines in the AASHTO "A Policy on Geometric Design of
Highways and Streets, 5' Edition" or latest, in the design and/or installation of
all landscaping and appurtenances abutting and within the private and public
street right-of-way.
PUBLIC SERVICES
74. The applicant shall provide public transit improvements as required by SunLine
Transit Agency and approved by the City Engineer.
MAINTENANCE
75. The applicant shall comply with the provisions of Section 13.24.160
(Maintenance), LQMC.
76. The applicant shall make provisions for the continuous and perpetual
maintenance of all private on -site improvements, perimeter landscaping, access
drives, and sidewalks. The applicant will prepare and submit documentation that
"runs with the land" for approval by the City Engineer and City Attorney for this
continuous and perpetual maintenance obligation.
FEES AND DEPOSITS
77. The applicant shall comply with the provisions of Section 13.24.180 (Fees and
Deposits), LQMC. These fees include all deposits and fees required by the City
for plan checking and construction inspection. Deposits and fee amounts shall
be those in effect when the applicant makes application for plan check and
permits.
78. Permits issued under this approval shall be subject to the provisions of the
Infrastructure Fee Program and Development Impact Fee program in effect at
the time of issuance of building permit(s).
79. On the day after City Council approval of the application, a check made out to
the "County of Riverside" for $2,832.25 shall be delivered to the Planning
Department for the environmental Notice of Determination fee.
MISCELLANEOUS
RESOLUTION NO. 2OO9-028
TENTATIVE PARCEL MAP 35088
MAYER VILLA CAPRI, L.P.
CONDITIONS OF APPROVAL - FINAL
ADOPTED: MARCH 17, 2009
Page 27 of 27
80. All applicable requirements of CUP 2007-105 and SDP 2006-875 shall be
complied with.
81. All mitigation measures contained in the Final Environmental Impact (EIR) Report
for EA 2006-582 shall be complied with. Said EIR is on file in the Planning
Department of the City of La Quinta.
82. The applicant shall, to the satisfaction of the City Engineer, comply with all
recommendations contained within the Transportation System
Management/Transportation Demand Management Study for the Washington
Street and Highway 111 Corridors.